Tender For Annual Repair And Maintenance Of To Fsd Nileswar For The Year 2023-24 Sh Replacement Of Existing Ac Sheet Roofing With Pre-Coated Galvanised Iron Profile Sheet Roofing For Jt1 And Jt2 Godowns, Kasaragod-Kerala

Food Corporation Of India-FCI has published Tender For Annual Repair And Maintenance Of To Fsd Nileswar For The Year 2023-24 Sh Replacement Of Existing Ac Sheet Roofing With Pre-Coated Galvanised Iron Profile Sheet Roofing For Jt1 And Jt2 Godowns. Submission Date for this Tender is 01-11-2023. Shed Construction Tenders in Kasaragod Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

40218007
Tender For Annual Repair And Maintenance Of To Fsd Nileswar For The Year 2023-24 Sh Replacement Of Existing Ac Sheet Roofing With Pre-Coated Galvanised Iron Profile Sheet Roofing For Jt1 And Jt2 Godowns
Open Tender
Indian
Kerala
Kasaragod
01-11-2023

Tender Details

Annual Repair And Maintenance Of To Fsd Nileswar For The Year 2023-24 Sh Replacement Of Existing Ac Sheet Roofing With Pre-Coated Galvanised Iron Profile Sheet Roofing For Jt1 And Jt2 Godowns

Key Value

Document Fees
Refer document
EMD
INR 165000.0 /-
Tender Value
INR 82.44 Lakhs /-

BOQ Items

Name of Work: ARMO to FSD Nileswar for the year 2023-24. SH: Replacement of existing A.C.sheet roofing with pre-coated galvanised iron profile sheet roofing for JT1 & JT2 godowns
Sl. No. Item Description
1Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
2Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar
3Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: Asbestos sheet .
4Providing and laying cement concrete in retaining walls, return walls,walls (any thickness) including attached pilasters,columns, piers,abutments, pillars, posts, struts, buttresses, string or lacing courses,parapets, coping, bed blocks, anchor blocks, plain window sills, fillets,sunken floor etc., up to floor five level, excluding the cost of centering,shuttering and finishing :1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) .
5Centering and shuttering including strutting, propping etc. and removal of form for :Lintels, beams, plinth beams, girders, bressumers and cantilevers
6Providing and fixing Green colour pre-coated galvanised iron profile sheets (size,shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required
7Providing and fixing green precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05 %) total coated thickness, Zinc coating120 grams per sqm as per IS: 277, in 240 mpa microns epoxy primer on both side of the sheet and polyester topsteel grade, 5-7microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete. Profiled ridge (950 to 1000 mm) Item similar to Item no 12.51.1 of DSR 2021
8Providing and fixing radial exhaust turbo ventillators/extractor capacity of minimum 100cuft per minute air circulated fan of 22" throat dia weight of 5.5kg having throat dia wind ventillator with FRP base plate, including cost of fixing turbo/wind ventillator on new 0.50mm thick pre-coated GI profile sheet roofing on godown roof lincluding the cost of transportation of all materials tools and plants, fixtures & fastenings. Labour, insurance, safety measures etc and as directed by the Engineer in charge including guarantee of turbo ventillators of minimum 03 years and performance warranty etc complete.( HQrs approved rate)
9Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One or more coats on old work.
10Extra for providing and fixing wind ties of 40x 6 mm flat iron section.
11Providing 250 mm PVC eave gutter 4kg/sq.cm as per standard design and manufacture with iron brackets, bolts, nutsand washers etc., including providing necessary spouts/shoesetc., completeas per thedirection of Engineer in charge( Cost of iron clamps and other fittings will be paidseparately )
12Providing flatiron brackets 50x6mm size with necessary bolts, nuts ,washers and welding etc.for fixing PVC eave gutter with purlines
13Providing 250 mm PVC drop having 160mm outletor nearest size as per manufacturers specification to suit the eave gutter etc.complete,
14Providing160 mm PVC Elbowas per manufacturers specification to suit the drop over theeave gutter etc.complete,
15Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down guage),finishing with cement mortar 1:3 (1 cement : 3 fine sand as per standard design: In 75X75 mm deep chaseItem No.12.21.1 of DSR 2021
16Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)Item No.6.4.2 of DSR 2021
1718 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 finished with a top layer 6mm thick cement plaster 1:6. Item No. 13.11 of DSR 2021
18Providing and fixing precoated galvanised iron plain profile sheets 0.50 mm (+ 0.05 %), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (Analysed based on Item No.12.50 of DSR 2021)
19Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated "J" or "L" hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system underapproximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 2 mm thick corrugated (2.5" or 4.2" or 6") or step-down (2" or 3" or 6" ) as specified Item No 12.47.1 of DSR 2021
20Lettering with black Japan paint of approved brand and manufacture DSR 2021- Item no.13.99.1
21Reparing/Servicing rolling shutters such as removal of top covers tightening/ loosening the springs adjusting the dislocation of parts if any and applying grease to the springs side guides ( 0.40 kg greese/ shutter) after cleaning and refixing the cover in position etc as directed by engineer in charge.
22Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : Of area 3 sq. metres and below (Item No.15.13.1 of DSR 2021)
23Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :Powder coated aluminium (minimum thickness of powder coating 50 micron)(Item No.21.1.1.2 of DSR 2021)
24Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: Float glass panes of thickness 4 mm. (Item no. 14.5.1 of DSR 2021)
25Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm)(Item No.21.3.1 of DSR 2021)
26Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete .Item No 13.88 of DSR 2021
27White washing with lime to give an even shade : Old work (two or more coats)Item No 13.87.1 of DSR 2021
28Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion (i) Single socketed pipes. 110 mm diameter (Item No 12.41.2 of DSR 2021)
29Deduct cost of salvagable materials received from the work of dismantling work on as is where is condition includingremoving from the site - AC sheet
30Deduct for Salvage value of dismantled PVC rain water pipes of 250mm Dia as is whereis basis. ( Market rate)
31Taking out wind ties from roof including cutting out rusted bolts, nuts etc. and removing materials to any distance within compound and stacking. (Item No.14.191 of DSR 2021)
32Deduct for Salvage value of dismantled materials of GI J bolts & MS Flats of wind ties as is whereis basis. ( Market rate)
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail