Tender For Maintenance Of Various Colonies Under South Zonesh:- Providing & Fixing Remaining Fire Alarm System In Bhikaji Cama Bhawan In Upper Lower Basement+1Floor., New Delhi-Delhi

Delhi Development Authority-DDA has published Tender For Maintenance Of Various Colonies Under South Zonesh:- Providing & Fixing Remaining Fire Alarm System In Bhikaji Cama Bhawan In Upper Lower Basement+1Floor.. Submission Date for this Tender is 20-10-2023. Alarm Systems Tenders in New Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

40207511
Tender For Maintenance Of Various Colonies Under South Zonesh:- Providing & Fixing Remaining Fire Alarm System In Bhikaji Cama Bhawan In Upper Lower Basement+1Floor.
Open Tender
Indian
Delhi
New Delhi
20-10-2023

Tender Details

Maintenance Of Various Colonies Under South Zonesh:- Providing & Fixing Remaining Fire Alarm System In Bhikaji Cama Bhawan In Upper Lower Basement+1Floor.; 1 Supplying, Installation, Testing & Commissioning Of Main Control And Indicating Panel Made Out Of 16 Swg Ms Sheet To Accommodate The Following Items Duly Powder Coated In Approved Colour With Louvers For Ventilation, Locking Arrangement, Audio And Visual Indication For Fire Alarm And Public Address System, Monitoring System Including Connections, Interconnections Etc Complete As Required.6 Zone Panel For Fire Alarm System 100 Watt Amplifier Racks Suitable For Operation On 230V Ac / 24V Dc Supply Conforming To Iec-268-3 Complete With Allaccessories As Required- 2 Nos. ( One To Act As Standby ) Talk Back Master Station With Led Ptt ( Press To Talk ) Push Button For Operation On 230V Ac / 24 V Dc Supply Conforming To Iec-268 For Simplex Mode Of Operation / Communication Suitable For 20 Nos.Talk Back Unit -1 Set.Annoucement Control Desk Suitable For Selection Of Different Zones Selectively And On All Call Switch With Visual Indication Etc., Complete As Required- 1 Set.Amplifier Change Over Switch For Inter Changing Amplifier- 1 No. Monitor Panel For Loudspeaker Complete Output Selector On / Off Switch, Fuse Visual Indications Etc. Complete As Required- 1 No.Gooseneck Microphone With Stand And On / Off Switch -1 No. Mains On / Off Switch, Fuse Indication Lamps, Dc And Acvoltmeters & Ammeters Terminal Blocks Etc. Complete Asrequired -1 Set.Battery Charger Trickle Cum Boost To Take Complete Load Offire Alarm & Pa System Complete With All Accessoriesincluding Providing & Fixing Of 2 Nos. 12 Volt, 30 Ah Eachsealed Maintenance Free Batteries -1 Set 2 Supplying, Installation, Testing & Commissioningsector Panel Suitableforfollowingzones, Completewithvisualindicationsfor Shortcircuitfault, Opencircuitfault, Fireconditionandallother Standard Facilities As Per Is:2189 With Mimic Diagram For All Area / Zonecovered, Completewithall Connections, Interconnections As Reouired. 3 Supplying &Layingof2x1.5Sqmmfirealarmarmoured Cable, 600 / 1000V Ratedwithannealedcopperconductor Having Xlpe Insulation, Steelwirearmouring& Frlsoutersheathcompleteas Required. 4 Supplying, Installation, Testing& Commissioningofmanualcall Box Of Abs Type In Surface / Recess With Stainlesssteel Chain& Hammer Assembly Complete With Glass And Push Button Etc. As Required. 5 Supplying, Installation, Testing & Commissioning Fire Alarm Sounder With Facility To Make Announcement, Mounted In M.S. Box ( 16 Swg ) With Hinged Cover Plate & Suitable For Operation With Amplifier I / C Line Matching Transformer Etc. Complete Asrequired. 6 Supplying, Installation, Testing&Commissioningofsmokedetector Withbuiltinledandmountingbasecompletewithallconnections Etc. As Required. 7 Supplying Installation Testing & Commissioning Of Laser Etched Led Light Exit Signage / Lift Signages Etc. On Ceiling / Wall Mounted ( With Logo & Exit Arrow ) Etching On 8Mm Transparent Acrylic Sheet Of 350 X 170Mm ( Normal Size ) Super Bright Led Less Then 2 Watt Having Ni-Mh / Nicd Battery With Back Up Of 10 Hours Of Standard Size Of 350Mmx170 Mm Recharge Period Of 12 Hours Operating Voltage Of -190 To 230Vfrom 230V Ac To 6V / 12V Dc With Nickel Cadmium Batteries And Battery Charger. Single Sided 8 Double Sided 9 Supply And Installation Of Self Illumination / Auto Glow Exist Signs On Photoluminescent Sheet 3 Mm. Aluminium Compasible Panel Double Side Containing Self Illuminated Base Chemical Of Appropriate Size Not Less Than 300Mm X 150Mm Suspended From Ceiling Of Fixed To The Walls With Accessories Etc. Asrequired.

Key Value

Document Fees
Refer document
EMD
INR 30664.0 /-
Tender Value
INR 15.33 Lakhs /-

BOQ Items

Name of Work:- Maintenance of various Colonies under South Zone SH:- Providing & fixing remaining fire alarm system in Bhikaji Cama Bhawan in Upper Lower basement+1floor.
Sl. No. Item Description
1Supplying, installation, testing & commissioning of main control and indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc complete as required.6 zone panel for fire alarm system 100 watt amplifier racks suitable for operation on 230V AC/24V DC supply conforming to IEC-268-3 complete with allaccessories as required- 2 Nos.(one to act as standby) Talk back master station with LED PTT (press to talk) push button for operation on 230V AC/24 V DC supply conforming to IEC-268 for simplex mode of operation/communication suitable for 20 Nos.talk back unit -1 set. Annoucement control desk suitable for selection of different zones selectively and ON ALL CALL switch with visual indication etc., complete as required- 1 set. Amplifier change over switch for inter changing amplifier- 1 No. Monitor panel for loudspeaker complete output selector ON/OFF switch, fuse visual indications etc. complete as required- 1 No. Gooseneck microphone with stand and ON/OFF switch -1 No. Mains ON/OFF switch, fuse indication lamps, DC and ACvoltmeters & ammeters terminal blocks etc. complete asrequired -1 set.Battery charger trickle cum boost to take complete load offire alarm & PA system complete with all accessoriesincluding providing & fixing of 2 nos. 12 volt,30 AH eachsealed maintenance free batteries -1 set
2Supplying, installation, testing & commissioningsector panel suitableforfollowingzones,completewithvisualindicationsfor shortcircuitfault,opencircuitfault,fireconditionandallother standard facilities as per IS:2189 with mimic diagram for all area/zonecovered,completewithall connections,interconnections as reouired.
3Supplying &layingof2x1.5sqmmfirealarmarmoured cable, 600/1000V ratedwithannealedcopperconductor having XLPE insulation,steelwirearmouring& FRLSoutersheathcompleteas required.
4Supplying,installation,testing& commissioningofmanualcall box of ABS type in surface/recess with stainlesssteel chain& hammer assembly complete with glass and push button etc. as required.
5Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.
6Supplying,installation,testing&commissioningofsmokedetector withbuiltinLEDandmountingbasecompletewithallconnections etc. as required.
7Supplying Installation testing & commissioning of Laser etched LED Light Exit Signage/ Lift Signages etc. on ceiling / wall mounted (with Logo & Exit arrow) etching on 8mm transparent acrylic sheet of 350 x 170mm (normal size) super bright LED less then 2 watt having NI-MH/NICD battery with back up of 10 hours of standard size of 350mmx170 mm recharge period of 12 hours operating voltage of -190 to 230Vfrom 230V AC to 6V/12V DC with nickel cadmium batteries and battery charger. Single Sided
8Double Sided
9Supply and installation of self illumination/auto glow exist signs on photoluminescent sheet 3 mm. aluminium compasible panel double side containing self illuminated base chemical of appropriate size not less than 300mm x 150mm suspended from ceiling of fixed to the walls with accessories etc. asrequired.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail