| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kind of soil. |
| 2 | Providing and laying in position Cement concrete of specified grade excluding the cost of centering and shuttering – All the work up to plinth level :1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size) |
| 3 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 4 | Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 5 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement – All work up to plinth level 1:1:5:3 (1 cement 1.5 coarse sand 3 graded stone aggregate 20 mm nominal size |
| 6 | Soild block masonry using pre cast soild blocks (Factory made) of size 40x20x15cm or nearest available size cofirming to IS 2185 part 1 of 1979 for super structure up to floor two level with thickness 15cm in CM 1:6 (1cement: 6 coarse sand) etc complete |
| 7 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level, Thermo-Mechanically Treated bars of grade Fe- 500D or more |
| 8 | Centering and shuttering including strutting, propping etc. and removal of form forFoundations, footings, bases of columns, etc. for mass concrete |
| 9 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood/jack wood |
| 10 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. Using Anjil wood/jack wood 30 mm thick shutters |
| 11 | Providing and fixing M.S. Grills of required pattern in frames of windows etc, with M.S. flats square or round bars etc. including priming coat with approved steel primer all complete, Fixed to openings/wooden frames with rawl plugs screws etc |
| 12 | Supplying and fixing rolling shutters of approved make, made of required size MS laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454- part 1 and M.S. top cover of required thickness for rolling shutters 80x1.25 mm M.S. laths with 1.25 mm thick top cover |
| 13 | Providing and fixing ball bearing for rolling shutters |
| 14 | Extra for providing mechanical device chain and crank operation for operating rolling shutters Exceeding 10.00 sqm and upto 16.80 sqm in the area |
| 15 | Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. Complete: 100x63x4 mm |
| 16 | 12 mm cement plaster of mix: 1:4 (1 cement: 4 coarse sand) |
| 17 | 6 mm cement plaster of mix:1:3 (1 cement : 3 fine sand) |
| 18 | 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand) |
| 19 | Pointing on stone work with cement mortar 1:3 (1 cement: 3 fine sand): Flush/ Ruled pointing |
| 20 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall Surface:Water thinnable cement primer |
| 21 | Finishing walls with Acrylic Smooth exterior paint of required shade: New work (Two or more coat applied @1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 22 | Wall painting with premium acrylic emulsion paint of interior grade. Having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour Two coats |
| 23 | Applying priming coat : With ready mixed red oxide zinc chromate primer of approved brand and Manufacture on steel galvanised iron/steel works |
| 24 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work |
| 25 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 26 | Supplying and fixing following way, single pole and neutral, sheet steel. MCB distribution board. 240 V on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCBIRCCB/Isolator2- 8 way, Double door) |
| 27 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2x1.5 sq.mm 1x1.5 sq.mm earth wire |
| 28 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch. Modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required. Group C |
| 29 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box Including connections but excluding modular plate etc. as required. 5/6 amps switch |
| 30 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. 3 pin 5/6 amp socket outlet |
| 31 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 32 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 12 Module (200mmx150mm) |
| 33 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden blockincluding connection etc as required. |
| 34 | Supply, Installation, testing and commissioning of pre-wired. 1200mm, 18/20w LED Single Tube fitting of All types, complete with all accessories etc. directly on ceiling/ wall, including connection with 1 5 sq. Mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |