| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains [not exceeding 1.5 m (one point five meter) in width or 10 sqm (ten square meter) on plan], including dressing of sides and ramming of bottoms, lift upto 1.5 m (one point five meter), including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m (fifty meter). All kinds of soil or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material. |
| 2 | Centering and shuttering including strutting, propping etc. and removal of form work All kinds of soil or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material for : |
| 3 | Foundation, footings, basis of columns etc. and mass concrete. |
| 4 | Flat surfaces such as soffits of suspended floors, roofs, landing and the like floor etc upto 200mm (two hundred millimeter) in thickness. |
| 5 | Columns, pillars, posts and struts. (square, rectangular or polygonal in plan). |
| 6 | Beams, cantilever, girders and lintels, sides and soffits of beams, beam haunchings, cantilevers, bressumers and lintels not exceedings 1mtr (one meter) in depth in all heights from floor. |
| 7 | Edges of slabs and breaks in floor and walls [under 20cm (twenty centimeter) width]. |
| 8 | Stair cases with sloping or stepped soffits excluding landing. |
| 9 | Providing and laying cement concrete 1:6:12 (one cement : six sand : twelve graded stone aggregate) 40mm (forty millimeter) nominal size and curing complete exluding cost of centring and shuttering in foundation and plinth All kinds of soil or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material. |
| 10 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level M-15 cement content 320 Kg/Cum (three hundred twenty Kilogram per Cubic Meter) or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material |
| 11 | Providing and laying in position machine batched and machine mixed design mix M-25grade cement concrete work, using cement constent as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommendd proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability as per direction of Engineer-in-Charge. \"(Note cement content considered in this item is Kg/cum. \"Excess/less cement used as per design mix is payable/recoverable @ 330 (three hundred thirty) separately. All works upto plinth level or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material. |
| 12 | Providing and laying in position machine batched and machine mixed design mix M-25grade cement concrete work, using cement constent as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommendd proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability as per direction of Engineer-in-Charge. \"(Note cement content considered in this item is Kg/cum. \"Excess/less cement used as per design mix is payable/recoverable @ 330 (three hundred thirty) separately. All works above plinth level upto floor V (five) level or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material. |
| 13 | Providing, hosting and fixing above plinth level upto all floorlevel precast reinforcement cement concrete in mouldings as in cornices, windows sills etc, including setting in cement mortar 1:3 (one cement : three coarse sand) cost of required centering, shuttering but, excluding the cost of reinforcement, with 1:1.5:3 (one cement : one point five coarse sand : three graded stone aggregate) 20mm (twenty millimeter) nominal size or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material. |
| 14 | Providing tor steel reinforcement for RCC work including bending, binding and placing in position complete upto all floor level or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material. |
| 15 | Applying cement slurry on R.C.C. slab or cement concrete work using 2.75 kg (two point seven five kilogram) of cement per sqm. of floor area before laying cement concrete flooring including roughening, cleaning of the concrete surfaces complete or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material. |
| 16 | Brick work using common burnt clay building bricks with rat trap bound in super structurein cement mortar 1:6 (one cement : six sand) 2nd class brickabove plinth level upto any floorlevel or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material. |
| 17 | Brick work using common burnt clay building bricks in super structurein cement mortar 1:6 (one cement : six sand) 2nd class brickabove plinth level upto all floorlevel or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material. |
| 18 | Half brick masonry in common burnt clay building bricks in super structurein cement mortar 1:4 (one cement : four sand) 2nd class brickabove plinth level upto all floorlevel or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material. |
| 19 | Random rubble masonry/polygonal rubble masonary (uncorsed/brought to cources) with hard stone of approved quality in foundation and plinth including leveling up with cement concrete1:6:12 (one cement : six sand : twelve graded stone aggregate) 20mm (twenty millimeter) nominal size at plinth level in cement mortar 1:6 (one cement: six sand) or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material. |
| 20 | Pre-cast concrete hollow block masonry in walls with sold concrete block (including quion block, jamp block, closer etc.) in cement morter 1:6 (one cement : six sand), concreter block made of cement concrete 1:3:6 (one cement : three : sand : six graded/crushed stone aggregate) 20mm (twenty millimeter) nominal size upto all floor level or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material. |
| 21 | Providing and fixing 40mm (forty millimeter) thick frame work 12 mm (twelve millimeter)prelaminated board both side bwp phenal bounded exterior/interior grade panelled shutters with frames of 1st class deodar wood for doors including bright finished/black enamelled iron butt hinges with necessary screws or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material. |
| 22 | Providing and fixing 300x16mm (three hundred into sixteen millimeter) anodized aluminium sliding door bolts anodized colour and shade with bolts and nuts screws etc. Complete or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material. |
| 23 | Providing and fixing 250x10mm (two hundred fifty into ten millimeter) aluminium tower bolts (Berrel type) anodized transparent or dyed to required shade and colour with screws etc. complete or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material. |
| 24 | Providing and fixing 100mm (one hundred millimeter) aluminium handles anodized transparent or dyed to required colour of shade with necessary screws etc. complete or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material. |
| 25 | Providing and fixing 150mm (one hundred fifty millimeter) bright finished brass floor door stopper with rubber cushion screws etc. to suit shutter thickness complete or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material. |
| 26 | Providing and fixing partical borad ceiling of approved quality with butt jointing and nails (frame work and cover fillets to be paid for separately) cement bounded partical board 8mm (eight millimeter) thick or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material. |
| 27 | Provding and fixing M.S grills of required pattern in wooden frames of windows etc with M.S flats, square or round bars with round headed bolts and nuts or by screws plain grill or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material. |
| 28 | Providing and fixing glass strips in joints terrazzo floors 40mm (forty millimeter) wide and 4mm (four millimeter) thck or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material. |
| 29 | Cement concrete flooring 1:2:4 (one cement : two sand : four graded stone aggregate) 20mm (twenty millimeter) nominal size laid in one layer finished with a floating coat of neat cement 40mm (forty millimeter) thickabove plinthlevel upto all floor level or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material. |
| 30 | Extra for making chequers of approved pattern on cement concrete of floors, steps, landings and pavement etc. or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material. |
| 31 | Cement plaster skriting upto 30cm (thirty centimeter) height with cement mortar 1:3 (one cement : three sand) finished with a floating coat of neat cement including rounding of junction with floor 15mm (fifteen millimeter) thick or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material. |
| 32 | Providing and fixing0.60 mm (zero point six zero millimeter) thick prepainted steel sheets in roofing with hot dipped metalic zinc coated sheets with top coat of regular modified polister organic coating of 20 microns over 5 microns primer coating + back coat of polister of 5 microns over 5 microns primer coating including fixing with prepainted iron J or L hooks, bolts and nuts 6mm dia and prepainted GI limpet and bitumen washer complete with all accessories as required or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material.. |
| 33 | Providing and fixing ridges or hips 60cm overall with 0.60 mm (zero point six zero millimeter) thick prepainted steel sheets in roofing with hot dipped metalic zinc coated sheets with top coat of regular modified polister organic coating of 20 microns over 5 microns primer coating + back coat of polister of 5 microns over 5 microns primer coating including fixing with prepainted iron J or L hooks, bolts and nuts 6mm dia and prepainted GI limpet and bitumen washer complete with all accessories as required or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material. |
| 34 | Structural steel work riveted, bolted or welded in built upto sections, trusses and framed work, including cutting, hosting, fixing in position and applying a priming coat of approved steel primer all complete or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material. |
| 35 | Providing and fixing MS BP Sheet 1.66mm to 2mm (one point six six millimeter to two millimeter) thick in eaves board/facia/soffits/ceiling including cutting, fixing and welding to steel roof members and applying a coat of red lead primer complete or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material. (base members of steel works shall be measured and paid separately). |
| 36 | Providing and fixing standard steel section of M.S. angle frame (Single rebate) and flat iron doors, windows and clerestory window manufactured from M.S. angle iron section of 40x40x5mm (forty into forty into five millimetre) and 50x5mm (fifty into five millimetre) MS flat iron section of 75x4mm (seventy five millimetre) thick including hinges, jambs, lock jamb,beed and ifrequired angle thrashold of mild steel angle 50x25mm (fifty into twenty five millimetre) welded or righdly fixed by machanical means, lugs with split end tails to each jambs including steel butt hinges 2.5mm (two point five millimetre) thick with provision for locking arrangement and shock observer as specified and applying a coat of approved steel primer after pre treatment of the surface or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material. |
| 37 | Providing and fixing standard steel section of ISLC and flat iron doors, windows and clerestory window manufactured from ISLC iron section 75x40mm (seventy five into forty millimetre) with MS flat iron section of 75x4mm (seventy five into four millimetre) thick including hinges, jambs, lock jamb,beed and ifrequired angle thrashold of mild steel angle 50x25mm (Fifty into twenty five millimetre) welded or righdly fixed by machanical means, lugs with split end tails to each jambs including steel butt hinges 2.5mm (two point five millimetre) thick with provision for locking arrangement and shock observer as specified and applying a coat of approved steel primer after pre treatment of the surface or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material. |
| 38 | Providing and fixing steel glazed framed shutter of Z-section with 4mm (four millimeter) thick glass panes with putty for doors, windows and clearestory windows required shape and section with fitting and necessary screws etc. including fixing iron hinges with necessary screws inluding applying a priming coat of red lead paint complete as per approved specification / design or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material. |
| 39 | Providing and fixing steel wire guage shutter in Z- sectionusing galvainsed MS wire gauge of IS gauge desination 85G with wire of dia 0.56mm (zero point five six millimeter) for doors, windows and clearestory windows including metal beadingof approved quality and shape section with necessary steel screws inluding applying a priming coat of red lead paint complete as per approved specification / design or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material. |
| 40 | Providing and fixing MS fan clamps type-I of 16mm (sixteen millimeter) dia MS bar bent to shape with hook ends with RCC slab during laying including painting exposed portion or loop all as per standard design complete or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material. |
| 41 | Providing and fixing 85cm (eighty five centimeter) height railing with MS rectangular hollow pipe 75x50mm (seventy five into fifty millimeter) of 14 (fourteen) gauge M.S.black sheet make hand rail and M.S. square bars 20mm (twenty millimeter) size ballusters at 30cm (thirty centimeter) centre to centre duly welded with 2Nos (two numbers). MS flat 40x6mm (forty into six millimeter) size and 20mm (twenty millimeter) M.S. square bars lugs 10cm (ten centimeter). long at lower end of ballusters embeded in RCC stepsor waist slab including priming coat of steel primer and painting with steel enamal paint other than white as per design or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material. |
| 42 | Applying priming coat over new steel and other metal surfaces after and including preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and scoured with wire brushes, fine steel wool scrapers and sand paper complete with ready mixed priming paint brushing red lead, red-oxide/zinc oxide chorme or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material. |
| 43 | Painting two coats (excluding priming coat) on new steel and other metal surfaces with enamel paint brushing to give an even shade including cleaning the surface of all dirt, dust and other foregin matter with ready mixedpaint other than white or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material. |
| 44 | Applying priming coat over new wood and wood based surfaces after and including preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter sand papering and knotting. Ready mixed paint brushing wood primer pink or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material. |
| 45 | Painting two coats (excluding priming coat) on new wood and wood based surfaces with ready mixed paint to give an even shade including cleaning the surface of all dirt, dust and other foregin matter sand papering and stoping with ready mixed paint other than white or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material. |
| 46 | 6mm (six millimeter) thick cement plaster to ceiling with cement mortar 1:4 (one cement : four sand) or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material. |
| 47 | 15mm (fifteen millimeter) cement plaster in single coat on rough side of brick/concrete/stone walls for interiorplastering upto all floor level including arrises, internal rounded angles, chamfers and/or rounded angles not exceeding 80mm (eighty millimeter)in girth and finished even and smooth. in cement mortar 1:6 (one cement : six sand)above plinth level upto all floorlevel or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material. |
| 48 | 15mm cement plaster in single coat on fair side of brick/concrete/stone walls for interiorplastering upto floor twol level including arrises, internal rounded angles, chamfers and/or rounded angles not exceeding 80mm in girth and finished even and smooth in cement mortar 1:6 (one cement : six sand) above plinth level upto all floorlevel or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material. |
| 49 | Distempering (two coats) with oil boundwashable distemper of approved brand and manufacture and of required shade on undecorated wall surfaces to give an even shade over and including a priming coat with distemper primer of approved brand and manufacture after thoroughly brushing the surface free from mortar dropings and other foreign matter and also including preparing the surface even and sand papered smooth on walls priming coat with distemper primer or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material. |
| 50 | White washing with lime on undecorated ceiling and/or slopingroof (two coats) to give an even shade inclduing throughly brooming the surface to remove all dirt, dust, mortar dirt and other foreign matter or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material. |
| 51 | Making plinth protection 50mm (fifty millimeter) thick of cement concrete 1:3:6 (onecement : three coarse sand : six graded stone aggregate) 20 mm (twenty millimeter) nominal sizeover 75mm (seventy five millimeter) thick bed of dry brick ballast 40 mm (forty millimeter)nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material. |
| 52 | Constructing coursed rubble hammer dressed U-Shape open surface drain with side wall 15x22cm (fifteen into twenty centimeter) with cement mortar 1:6 (one cement : six sand) and inside plastering with cement mortar 1:3 (one cement : three sand) including earth work and laying 10cm cement concrete 1:5:10 (one cement : five sand : ten graded stone aggregate) 40mm (forty millimeter) nominal size and 7.5cm (seven point five centimeter) cement concrete 1:2:4 (onecement : two sand : four graded stone aggregate) of 20mm (twenty millimeter) nominal size and finished with a floating coat of neat cement complate as per standard design or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material. |
| 53 | Providing and fixing to wall, ceiling and floor galvanised mild steel tubes (Medium grade) tube fitting and clamps including making good the wall, ceiling and floor 15mm (fifteen millimeter) nominal bore or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material. |
| 54 | Providing and laying in trenches, galvanised mild steel tubes (medium grade), tube fittings (earth work in trenchesto be measured and paid separately 15mm (fifteen millimeter) nominal bore or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material. |
| 55 | Providing and fixing PVC water storage tank of ISI: 12701 marked, G.I. intel and outlet connection, 15mm (fifteen millimeter) nominal bore ball valve and mosquito proof PVC cover with locking arrangement including hoisting up to all heights above ground level 500 liters(five hundred liters) net capacity tank or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material. |
| 56 | Providing and fixing high pressure PVC spigot and soil, waste and ventilating pipes ISI marked including fixing with approved adhesive etc. Complete. |
| 57 | Providing and fixing PVC collars ISI marked including fixing with approved adhesive etc. complete or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material. |
| 58 | Providing and fixing PVCplain bend ISI marked including fixing with approved adhesive etcetera complete or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material. |
| 59 | Providing and fixing PVC floor trap ISI marked of self cleaning design including fixing with approved adhesive, cost of cutting and making good the wall and floor etc. Complete or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material. |
| 60 | Providing and fixing laboratory sink with C.I. or M.S. brackets painted white including cutting holes in walls and making good the same but excluding fittings Viteous China 600mmx450mmx150mm (six hundred millimeter into four hundred fifty into one hundred fifty millimeter) or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material. |
| 61 | Providing and fixing C.P. Brass chain 50cm long and rubber plug of following sizes for sink or wash basin 32mm (thirty twomillimeter) dia or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material. |
| 62 | Providing and fixing C.P. Brass waste for wash basin or sink 32mm (thirty two millimeter) dia or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material. |
| 63 | Providing and fixing M.I. Union for wash basin or sink 32mm (thirty two millimeter) dia or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material. |
| 64 | Providing and fixing C.P. brass pillar tap with capstan head 15mm (fifteen millimeter) dia or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material. |
| 65 | Providing and fixing C.P. Brass angle valve 15mm (fifteen millimeter) dia. without Nuts and pipe or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material. |
| 66 | Providing and fixing P.V.C. connection with brass unions 450mm (four hundred fifty millimeter) length 15mm (fifteen millimeter) dia or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material. |
| 67 | Providing and fixing brass full way valve with wheel 15mm (fifteen millimeter) nominal bore or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material. |
| 68 | Providing and fixing lead waste pipe 32mm (thirty two millimeter) dia for wash basin or sink or as per direction of Engineer-in-Charge within all leads, lifts and other incidentals including carriage of material. |