Tender For Proposed Extension Of Snltr Office Module At 6Th Floor In Moni Bhandar Building , Civil & Interior Works , 15Mmthick (Average) Cement Plaster L:6 (1 Cement : 6Medium Sand) To Uneven Surface, Walls (Risers Or Set Back), Inside Of The Masonr, 24 Paraganas North-West Bengal

West Bengal Electronics Industry Development Corporation Limited has published Tender For Proposed Extension Of Snltr Office Module At 6Th Floor In Moni Bhandar Building , Civil & Interior Works , 15Mmthick (Average) Cement Plaster L:6 (1 Cement : 6Medium Sand) To Uneven Surface, Walls (Risers Or Set Back), Inside Of The Masonr. Submission Date for this Tender is 24-11-2023. Nuts Supply Tenders in 24 Paraganas North West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

40166923
Corrigendum : Tender For Proposed Extension Of Snltr Office Module At 6Th Floor In Moni Bhandar Building , Civil & Interior Works , 15Mmthick (Average) Cement Plaster L:6 (1 Cement : 6Medium Sand) To Uneven Surface, Walls (Risers Or Set Back), Inside Of The Masonr
Open Tender
Indian
West Bengal
24 Paraganas North
24-11-2023

Tender Details

Proposed Extension Of Snltr Office Module At 6Th Floor In Moni Bhandar Building , Civil & Interior Works , 15Mmthick ( Average ) Cement Plaster L:6 ( 1 Cement : 6Medium Sand ) To Uneven Surface, Walls ( Risers Or Set Back ) , Inside Of The Masonry Surface, Beams & Column Flushed With Brick Wall Including Extra Thickness Of Mortar Due Toinequalities Of Brick Work & Extra Cement Required For Plastering Tor.C. Surface, Rakingout Joints Including The Cost Of Chiselingtheundulating Surface Of Brick Masonry Or Chipping Out R.C Surface Where Necessarycomplete In All Respects As Per Specification Including Necessary Scaffolding Etcwith All Labour And Materials To All Floors. , Providing And Applying Two Coats Of Plastic Emulsion Paint Of Approved Shade And Quality Over A Coat Of Cement Primer I Including ) Of Approved Quality On Wall, Column, Beams, Ceiling Etc Over Pop Surface Including Preparation Of Surface As Per Direction Including Providing Necessary Putty Work, Scaffolding Etc Complete With All Labour And Materials In All Floors. Work Should Be Executed As Per Manufacturers Specification. , Painting Two Or More Coats Of Approved Synthetic Enamel Paint Over A Coat Of Approved Primer ( Including ) Suitable As Per Manufacturers Specification To Achieve The Desired Finish Over Wall Surface / Wooden Surfaces / Other Surfaces After Preparation Of Surface Properly As Per Direction With All Labour And Materials. The Item Is To Be Completed In All Respects As Per Directions With All Labour And Materials. , Joinery Surface , Steel Surface , Wood Work In Door And Window Frame Fitted And Fixed In Position Complete Including A Protective Coat Of Painting At The Contact Surface Of The Frame Exluding Cost Of Concrete, Iron Butt Hinges And M.S Clamps. ( The Quantum Should Be Correted Upto Three Decimals ) . Sal Local. At Any Floor & Any Location. , Wood Work In Door And Window Frame Fitted And Fixed In Position Complete Including A Protective Coat Of Painting At The Contact Surface Of The Frame Exluding Cost Of Concrete, Iron Butt Hinges And M.S Clamps. ( The Quantum Should Be Correted Upto Three Decimals ) . 1St Class Best Indian Teak. At Any Floor & Any Location. , Supplying, Fitting And Fixing Boiling Water Proof Ply Conforming To Is: 710-1977 Bonded With Phenol Formaldehyde Synthetic Resin Conforming To Is: 848-1974 Of Approved Make And Brand Fitted And Fixed As Per Design As Direction Of Engineer-In-Charge. [ Excluding The Cost Of Supporting Frame Work Per Approval And And Teak Wood Batten / Lipping ] At Any Floor & Any Location. , 6Mm , 9Mm , 12Mm , 19Mm , Supplying, Fitting And Fixing Boiling Water Resistant Ply Conforming To Is: 303- 1989 Bonded With Phenol Formaldehyde Synthetic Resin Of Approved Make And Brand Fitted And Fixed As Per Design As Per Approval And Direction Of Engineer-In- Charge.At Any Floor & Any Location. , 9Mm , 6Mm , Supplying, Fitting & Fixing Of Aluminium Fixed Partion Wall Of All Aluminium Sections Viz Top, Bottom And Side Member, Intermediate Member, Glazing Clip Made Of Aluminium Alloy Extrusions Conforming To Is: 733-1983 And Is: 1285-1975, Annodized Conforming To Is:1868- 1983, Fitted With All Other Accessories Viz. Epdm Gusket, Cleat, Angle Screws Etc. Including Labour Charges For Fitting And Fixing Of Aluminium Fixed Partition Wall With Glass / Panel Board All Complete As Per Architectural Drawings And Direction Of Engineer-In-Charge. ( Excluding Cost Of Glass / Panel Board, 10-12 Micron Thickness Annodizing Film. Natural White. , A ) For Unsupported Length Of Vertical Member Upto 1.50M. Height Of Both Ends Of Vertical Member Restrained But Panel With In 0.90 Sqm , B ) For Unsupported Length Of Vertical Member Above 1.50M. Height Of Both Ends Of Vertical Member Restrained But Panel Above 0.90 Sqm , Providing And Laying 50Mm Thick Expanded Polystyrene Block ( Self Extinguishing Type ) Having Density 34.00Kg / Cum, Thermal Conductivity 0.28 W / M-K, Water Absorption 0.1% ( Maximum To Be Laid Inside The Partition Wall By Adhesive / Fasteners As Per Manufacturers Specification And Specific Direction, Complete With All Materials And Labour. , Partition Of Teak Veneer As Per Design Fitted And Fixed Complete ( Excluding The Supporting Frame Work ) . 4Mm Thick Commercial Quality. At Any Floor & Any Location. , Supplying Solid Flush Type Doors Of Deluxe Decorative ( Both Side ) Quality, Conforming To I:S 2202 Timber Frame Consisting Of Top And Bottom Rail And Side Styles Of Well Seasoned Timber 65Mm Wide Each And The Entire Frame Fitted With 27.5Mm Wide Battens Places Both Ways In Order To Made The Door Of Solid Core And Internal Lipping With Teak, Mahogony Or Rose Wood Approved Decorative Veneers Using Phenol Formaldehyde As Glue Etc. Complete, Including Fitting, Fixing The Shutters In Position But Excluding The Cost Of Hinges And Other Fittings In Any Floor: ( A ) 35Mm Thick Shutters ( Single Leaf ) , Providing, Fitting And Fixing In Position Frameless Fully Glazed Composite Door Fixed To The Lintel And Floor Fitted With Necessary Ss Patch Fittings With Double Action Floor Spring Including Providing 12 Mm Thick Toughened Float Glass Of Special Selected Quality Free From Bubbles, Holes Or Any Surface Deformation. Allow For Cutting, Chase To Walls, Lintel And Floor And Mending Good Damages. The Rate Shouldinclude For Providing Necessary Approved Qualitylocks, Handles Etc Complete Inall Respects Withnecessary Patch Fittings & Fixtures, Stainless Steel Pivot Support As Per Drawing And Direction With All Labour And Materials. A ) Sliding / Swing ( Door ) With Necessary Top And Bottom Channles And Slidders With A Provision Of Movement Sensor. ( Sensor To Be Paid Separately ) . , French Polishing To Wood Work Including Preparing Surface. High Gloss Polish With Lacquer Finish. On New Wood Work. At Any Floor & Any Location. , Supplying Fitting, Fixing Decorative Lamination Conforming To Is: 2046 : 1995 As Per Approved Make, Brand, Finish And Thickness With Fitting, Fixing The Same On Particle / Mdf / Ply Boards With Recommended / Approved Adhesive With Proper Clipping The Sides For Better Attachment As Per Direction Of Engineer-Incharge. The Rate Includes The Cost Of Labour, Adhesive And All Incidental Charges Thereof. Glossy / Matt / Suede Excluding Surface Texture Or Metallic Lustre. Thickness Of Laminate 1 Mm. At Any Floor & Any Location. , Supplying, Fitting And Fixing 8Mm Thick Laminated Wooden Flooring Work Conforming To En13329:2006 With Plank Size Not Iess Than 1200 Mm X 190 Mm ( With Unilin / Tongue-Groove Locking Arrangement ) Having 0.2Mm Thk Top Abrasive Layer Over A Decorative Layer Followed By A High-Density Fibreboard ( Hdf ) Having Density > 850 Kg / M3 Substrate Core Over A Rasin Saturated Backing Layer And Installing Through Unilin Or Tongue- Groove System ( Having Locking Strength Not Less Than 1000 Kg / M ) Over A 2 Mm Thk Underlayer Polyurethene Foam On Polythene Sheet 250 Micron, Over A Smooth, Flat, Hard Subfloor Free From Moisture ( < 8% ) , Grease Etc. Complete In All Respect With Requisite Accessories Like End Profile, Transition Profile, Reducer T Profile Etc. Wherever Required And Preparation Of Base Including All Other Incidental Works As Per Direction & Satisfaction Of Engineer In Charge. Cost Of Laminate Floor Accessories Only ( Skirting , End Edge, T- Moulding, Reducer ) Shall Have To Be Added Separately, Wherever Required. Category: Normal Footfall; Class- 23;Abrasion Resistance:-Ac3 Thk On Swelling:- < 18% ;Impact Resistance:- Ic 1 , Providing And Fixing Of False Ceiling With Powder Coated Exposed G.I. Grid Suspension System ( E-Grid U-1520 Or Equivalent Load Carrying Capacity With Mid Span Deflection Not Exceeding 1 / 360 Span With Hanger Spacing Of 1200Mm C / C ) Consisting Of Main Runner 3600 Mm Long, Cross Tee 1200 Mm / 600 Mm Long And Wall Angle. The Wall Angle Shall Be Fixed On Pvc Dash Fasteners On The Perimeter Of The Wall By Steel Screws With Distance 300Mm C / C. The Main Runners To Be Placed @ 1200 Mm. The Cross Tee 1200Mm Will Be Inserted In The Pre-Cut Slots Of Main Runner At A Regular Interval Of 600 Mm To Form A Modular Grid Of 1200Mm X 600Mm. Additional Cross Tees Of 600 Mm Shall Be Placed Perpendicular To The Cross Tee 1200 Mm Long To Finally Form A Grid Of 600 Mm X 600 Mm. Grid Of Module Size 600 Mm X 600 Mm Shall Be Supported By 6 Mm Diag.I. Wire From Purlins / Soffit. 15Mm Thick Ow Acoustic Board ( Mineral Fiber Acoustic Ceiling Tiles ) Of Approved Patern And Size 595Mm X 595Mm With Nrc Value > 0.65 Should Be Placed In The Grid Module To Form A False Ceiling. All Complete As Per The Drawing & Directions Of Engineer-In-Charge. In Any Floor. , Rendering The Surface Of Walls And Ceiling With White Cement Base Water Proof Wall Putty Of Approved Make & Brand. ( 1.5 Mm Thick ) , Chair Providing & Installation Of Mid Back Chairs With Mesh For Back & Seat In Fabric, Tilting Back Rest, Fixed Armrests With Cantilever Base And Castor. , Supply, Fitting & Fixing Of Magnetic Lock. As Per Approved Brand. , Supply, Fitting & Fixing Of Cabinet Lock. As Per Approved Brand. , Anodised Aluminium Barrel / Tower / Socket Bolt ( Full Covered ) Of Approved Manufactured From Extruded Section Conforming To I.S. 204 / 74 Fitted And Fixed With Cadmium Plated Screws: 100Mm Long X 10Mm Dia. Bolt. As Per Approved Brand. , Supplying, Fitting And Fixing Ss Hinge Cleat In Position Excluding The Cost Hinge And Other Fiffitngs. 50Mm , Iron Butt Hinges Of Approved Quality Fitted And Fixed With Steel Screws, With Isi Mark. ( I ) 100Mm. X 50Mm. X 1.25Mm. , Supply, Fitting & Fixing Of Telescopic Channel For Drawer Fixing Purpose. As Per Approved Brand. , Anodised Aliminium D-Type Handle Of Approved Quality Manufactured From Extruded Section Conforming To I.S. Specification ( I.S. 230 / 72 ) Fitted And Fixed Complete. Without Base. 100 Mm Grip X 10 Mm Dia Rod. As Per Approved Brand. , Supply, Fitting & Fixing Of Autoclosing Hinges For Cabinet Shutter. As Per Approved Brand. , Supply, Fitting & Fixing Of Venetian Blind With Necessary Frame Work For Glass Windows. As Per Approved Brand. , Hydraulic Door Closer Of Approved Quality As Per I.S.I. Standard Fitted And Fixed Complete. Godrej Hydraulic Door Closer Fitted And Fixed Complete. Heavy Type. , Supplying, Fitting & Fixing Stainless Steel D Or H Type Of Size 300 Mm X 19 Mm Tubular Handle With Grade 304, Ce Certified, Marked & Conforming To En - 1154, Of Approved Quality Of Reputed Brand As Per Direction Of Eingineer-In- Charge Fitted And Fixed Complete Including All Incidental Charges. , Supply Fitting & Fixing Of Door Stopper ( Brass ) . As Per Approved Brand. , Supplying Mortice Lock Chromium Plated With Keys 6 Levers Including Fitting & Fixing Complete. , Dismantling The Existing False Ceilingboards And Its Frame Work And Removing & Stacking The Same As Per Direction Of Onwer. , Removing Carefully Existing Plaster / Skirting Of Any Thickness As Per Direction From Wall, Ceiling Etc Including Preparation Of Surface To Receive New Plaster, Removing Debris From Work Site. Complete With All Labour And Materials In All Floors. , Taking Out Carefully Existing Partition With Frame, Aluminium Doors , Floor Springs, Loose Furniture ( Cheir , Table, Cup Boards, Computer Etc. ) , Shiftring To 7Th Floor And Stacking Properly For Re Use . All Surplus Materials Debrish Shall Be Remove D At Any Suitable Place As Per Direction Of Owner , Payment Will Be Made As Per Floor Area , Taking Out Carefully Existing Collapsible Gate / Grills And Refixing The Same In Position After Repairing And Painting Including Preparation Of Surface The Same As Per Direction To Match With Existing Gate Complete With All Labour And Materials. , Electrical Work , Mcb Distribution Board , Supplying And Fixing Of Surface / Flush Mounting Double Door Vertical Tpn Mcb Distribution Board For Mcb Db With Ip-42 / 43 Protection, Concealed In Wall After Cutting The Wall & Mending Good The Damages To Original Finsh Incl. Inter Connection With Suitable Size Of Copper Wire And Neutral Link & Provision For Earthing Attachment. The Rate Shall Include Necessary Civil Work For Installation As Required. , Up To 160A , 6 Way Enclosure ( Ltvd06mgn ) , Sit & C Of Surface / Flush Mounting Of Double Door Horizontal Tpn Mcb Distribution Board With Ip-42 / 43 Protection, Concealed In Wall After Cutting The Wall & Mending Good The Damages To Original Finish Incl. Inter Connection With Suitable Size Of Copper Wire And Neutral Link & Provision For Earthing Attachment. The Rate Shall Include Necessary Civil Work For Installation As Required. , 4 Way Enclosure ( 607715 ) , Sit & C Of Surface / Flush Mounting Of Double-Door Spn Mcb Distribution Board With Ip-42 / 43 Protection, Concealed In Wall After Cutting The Wall & Mending Good The Damages To Original Finish Incl. Inter Connection With Suitable Size Of Copper Wire And Neutral Link & Provision For Earthing Attachment. , 2+8 Way Enclosure ( 607711 ) , Mcb , Supplying And Fixing 240 / 415V Mcb Of Breaking Capacity 10Ka & C Characteristics On Din Rail Of Existing Dbs And Necessary Connection As Required , 6-32A Sp , 6-32A Dp , 6-32A Tp , 6-32A Fp , 63A Fp , Surge Protective Device , Supplying And Fixing Class-2 ( T2 ) 415V, Fp Surge Protective Device ( Spd ) Of Imax 40Ka / Pole Mounted On Din Rail Of Existing Dbs And Necessary Connection , Mcb Enclosure Box For Ac Odu , Supplying And Fixing Of 6-32A Fp Isolator With Metal Enclosure ( Outdoor Type-Ip65 ) Near Ac Odu ( Concealed / Surface ) & Mending Good The Damages To Original Finish Including Painting, Connection & Provision For Earthing Attachement. , Supplying And Fixing Of 6-32A Dp Isolator With Metal Enclosure ( Outdoor Type-Ip65 ) Near Ac Odu ( Concealed / Surface ) & Mending Good The Damages To Original Finish Including Painting, Connection & Provision For Earthing Attachement. , Mv Cable , Supplying, Laying, Testing And Commissioing Of 1.1Kv Grade, A2xfy Xlpe Armoured Aluminium Cable Of Following Size With All Necessary Accessories Required For Installation On The Wall Above False Ceiling And Concealed / Surface On Wall Below The False Ceiling, Rate Shall Include With 2 Nos. 10 Swg Gi Earth Continuity Wire For Running Earth And All Civil Work Like Cutting Dressing Mending Good Damages As Required. , 4 Core 25 Sqmm , Cable End Termination , Supplying And Fixing Double Compression Type Gland Complete With Brass Gland, Brass Ring & Rubber Ring For Dust & Moisture-Proof Entry Of Xlpe Armoured Cable As Below: , 4 Core 25 Sqmm , Finishing The End Of Following Xlpe Armoured Cables By Crimping Method Incl. Supplying And Fixing Solderless Socket ( Dowels Make ) , Tapes, Anticorrosive Paste & Jointing Materials: , 4 Core 25 Sqmm , Sub Mains / Circuit Mains , Wiring With Pvc Insulated & Unsheathed Single Core Stranded Copper Wire ‘Fr – In Pvc Rigid / Flexible Conduit Fr ( Isi Marked ) On Wall / Ceiling / Furniture As Per Site Requirement ( Concealed / Surface ) , Supplying & Drawing Of Wiring In 11Kv Single Core Stranded Fr Pvc Insulated & Unsheathed Copper Wire In 20Mm Size Pvc Rigid / Flexible Conduit ( As Per Direction By Eic ) Fr Including Neccessary Fittings And Neccessary Connections As Required , 2 X 36 / 0.3 ( 2.5 Sqmm ) + 1 X 22 / 0.3 ( 1.5 Sqmm ) Ecc. , 2 X 56 / 0.3 ( 4 Sqmm ) + 1 X 36 / 0.3 ( 2.5 Sqmm ) Ecc. , Supplying & Drawing Of Wiring In 1.1 Kv Single Core Stranded Fr Pvc Insulated & Unsheathed Copper Wire In 25Mm Size Pvc Rigid / Flexible Conduit ( As Per Direction By Eic ) Fr Including Necessary Fittings And Necesaary Connections As Required , 4 X 56 / 0.3 ( 4 Sqmm ) + 2 X 36 / 0.3 ( 2.5 Sqmm ) Ecc. , 4 X 84 / 0.3 ( 6 Sqmm ) + 2 X 56 / 0.3 ( 4 Sqmm ) Ecc. , Wiring With Pvc Insulated & Unsheathed Single Core Stranded Copper Wire ‘Fr – In Pvc Casing-Cappingon Wall / Ceiling / Furniture As Per Site Requirement , Supplying & Drawing Of Wiring In 1.1 Kv Grade Single Core Stranded Fr Pvc Insulated & Unsheathed Copper Wire Of Following Sizes In 25Mm Pvc Casing-Capping ( As Per Direction By Eic ) Including Necessary Pvc Clips, Fittings, Necessary Connections As Required , 2 X 36 / 0.3 ( 2.5 Sqmm ) + 1 X 22 / 0.3 ( 1.5 Sqmm ) Ecc. , Point Wiring , Supplying And Carrying Wiring For Light, Fan And Dependent Socket Points By Using 16 Swg Ms / Pvc Conduits With Threaded Joints Of Required Dia As Per Is 732, Ms / Pvc Conduit Accessories, Ms / Pvc Flexible Conduit With Couplers For Drops With Accessories, 2 X 1.5 + 1 X 1.5 Sq Mm, 1100V Grade Frls Pvc Insulated Copper Wires Approved 6A Modular Type Switches And Sockets With Plates And All Accessories For Fixing In Modular Furniture, Gi / Pvc Boxes And Other Point Wiring Accessories And Carrying Out Surface / Concealed Conduit System Of Wiring As Per Requirement With All Wiring Materials. Conduits Shall Run On Surface Of The Ceiling Above False Ceiling And Concealed In Wall By Cutting Chase In Wall And Mending Good Of All The Damages. All Points Shall Be Earthed With 1.5 Sq Mm Frls Flexible Copper Wire. Wires Shall Be Terminated At Light Fixtures With Ferrules, 16A, 4 Way Connector, Wire Ends Shall Not Be Kept Loose / Bare. The Rate Shall Also Include All Accessories Of Ms / Pvc Conduits, Etc, Necessary Civil Works For Embedding Conduits And Boxes Below False Ceiling, Wherever Applicable. , 1 Light Point Controlled By 1 No. 6A Switch , 2 Light Points Controlled By 1 No. 6A Switch , 3 Light Points Controlled By 1 No. 6A Switch , Fan Point Controlled By 6A Switch & Ceiling Rose Near Fan , Switches & Sockets , Sit & C Of The Following Components Like Approved Plate Type Modular Switches, Socket Etc. Duly Wired. , 1 No. - 6 / 16A, 6 Pin In Universal Socket Controlled By 16A, Sp Switch, Rp In Workstations And In Cabins, With Ms / Pvc Box. , Same As Above But Without Ms / Pvc Box , 3 Nos - 6A, 5 Pin Socket Controlled By Common 16A, Sp Switch, Workstations Without Ms / Pvc Box , Same As Above But With Ms / Pvc Box , 1 No. - 6A, 5 Pin In Universal Socket Controlled By 6A, Sp Switch, For Wi-Fi With Ms / Pvc Box. , Ac Sockets & Starter , Supply And Flush Fixing Of Modular Type Heavy Duty Plug Socket Unit Comprising Of 16 / 25A Socket And Plug Top ( With Indicator ) And Solid State Type Starter Units Of Electronic Type With Highflow Voltage Protections, O / L Protect Etc And Suitable For Ac Units Modular Type And Completely Wired Including Cutting Chases And Mending Good Damages, Painting, Earthing, Neccessary Connections Complete, As Per Required For Ac Units. , Empty Conduits , Supply And Fixing Of Frls Pvc ( Isi Marked ) Conduit ( Rigid / Flexible ) Of Various Dia, Exposed Or Concealed With All Accessories Like Tees, Bends, Glands Etc. Jbs ( Pvc ) As Required And Fish Wire Etc For Wiring Purpose Complete And Mending Good Damages To Building Works. , 20 Mm Dia ( 2 Mm Thick ) , 25 Mm Dia ( 2 Mm Thick ) , Supplying And Fixing Pvc Casing-Capping On Wall Or Ceiling, Including Elobw, Necessary Pvc Fittings Etc. Amd Mending Good Damages To Building Works , 20X10 Mm Size , Suplying And Fixing Of 5.5 X 5.5 Sheet Steel Cover On Floor Jb , Light & Fan Fixture Work , Indoor Type Luminaire , Supply, Installation, Testing And Commissioning Of Light Fixture Complete With All Fittngs & Accessories, As Required. Erection Rate Shall Include Necessary Gi Chain And Supporting Suspending Hardware For Fixing The Light Fittings. , Recessed Mounted Led Light Fixture ( Philips Rc380b Led36s-6500 G6 L60w60 Psu Od ( Fullglow ) Or Similar Approved Equivalent ) . , Recessed Mounted Down Light 20W Round Led Light Fixture ( Philips Dn296b Led20s-6500 Psu Wh Or Similar Approved Equivalent ) . , Wall Mounting Fan , Supply, Installation, Testing & Commissioning Of Decorative Wall-Mounted Oscillating Type Fan With Inbuilt Speed Controller. The Rate Shall Be Inclusive Of Fixing & Mounting Accessories And Making Necessary Connections As Required. Fixing Only Cabin Fan On Wall / Ceiling By S&F Rag Bolts, Nuts & Washers ( 6 Mm Dia X 62 Mm Long ) Or As Reqd. Incl. S&F 24 / 0.20 Pvc Insulated Flexible Copper Wire 0.5 Mt. Length , 450Mm Sweep Wall Fan. ( Havells Airboll Hi-Speed Or Similar Approved Equivalent ) , Dismantling / Removal , Dismantling / Removal Of Existing Light Fittings, Switch Boards, Conduit Etc. , Cassette Type Split Ac , Supply, Installation, Testing & Commissioning Of Air Cooled Cassette, Non-Inverter Split Type Air Conditioning Machines Of Following Cooling Capacities With Rotary / Twin Rotary Type Compressor. The Condenser Will Comprise Of Copper Tube Aluminium Finned Coil With Safety Controls And Refrigerant Gas - R32 / R 410A Gas As Required. , 2.0 Tr - 2 Star , 3.0 Tr- 2 Star , Refrigerant Piping , Supply And Installation Of Soft Drawn Refrigerant Piping For The Abovementioned Cassette A.C. Units Including Nitryle Rubber Insulation. , Cabling , Supply And Installation Of Electricalpower / Control Cablingof Suitable Size Between Indoor Units And Outdoor Units. , 4C X 2.5 Mm , Drain Piping , Supplying And Laying Of Condensate Drain Line Withpvc Pipe Complete With All Accessories With 6Mm Nitryle Rubber Insulation. , 25Mm , 32 Mm , Odu Structure , Supplying And Installation Of Ms Fabricated Odu Angle ( 50X50x6 Mm ) Structure For Installation Of Out Door Unit With All Accessories Including Ribbed Neoprene Vi Pads, Painting Two Coats With Synthetic Enamel Paint Over A Coat Of Red Oxide Primer Etc For Cassettes. , Misc Ac Work Including Civil Work For Breaking Wall For Copper Pipe, Cable & Drain Water Line, Scaffolding / Lifting Etc And Mending Good Damages Complete. , Dismantling Of Existing 17 Tr Ac Machine ( Idu & Odu ) , Ac Pipes, Ducts, Diffusers, Cables Etc. And Storing The Same Carefully As Directed By E.I.C. , Fire Work , Dismantling Carefully The Existingfire Sprinkler From Old False Ceiling, Storing The Same Carefully And Fixing The Same In New False Ceiling With Necessary Clamps Etc. Complete , Dismantling Carefully The Existing Smoke Detector From Old False Ceiling, Storing The Same Carefully And Fixing The Same In New False Ceiling With Necessary Wire Etc. Complete. , Supply And Fixing Fire Exit Signage ( I.E., Fire Exit ) In Aclyric Sheet With Vinyle Painted With All Accessories Complete.Size Shall Be 6X12 , Dismantling The Existing 6W Speaker And Reinstallation Of The Same In New False Ceiling With Necessary Fittings As Complete. , Sitc Of 15 Mm Size Quartz Bulb Type Fire Sprinkler Of Rating 68 Deg.C With Required Accessories. As Complete. , 65 Inch. Interactive Flat Panel With Trolly Incl. Octacore Processor / 8Gb Ram / 32Gb Storage / 2*16W Speaker / 3 Years Warranty / Hdmi Cable / Display Adapter

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 03-Nov-2023 Prebid Minutes_Proposed Extension of SNLTR office module at 6th floor in Moni Bhabdar Building Technical Bid 08-11-2023
2 10-Nov-2023 DATE1 Date 24-11-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 61150.0 /-
Tender Value
INR 30.56 Lakhs /-

BOQ Items

Name of Work:Proposed extension of SNLTR office module at 6th floor in Moni Bhandar Building
Sl. No. Item Description
1CIVIL & INTERIOR WORKS
215mmthick (average) cement plaster l:6 (1 cement : 6medium sand) to uneven surface, walls (risers or set back), inside of the masonry surface, beams & column flushed with brick wall including extra thickness of mortar due toinequalities of brick work & extra cement required for plastering toR.C. surface,rakingout joints including the cost of chiselingtheundulating surface of brick masonry or chipping out R.C surface where necessarycomplete in all respects as per specification including necessary scaffolding etcwith all labour and materials to all floors.
3Providing and applying two coats of plastic emulsion paint of approved shade and quality over a coat of cement primer I Including) of approved quality on wall, column, beams, ceiling etc over POP surface including preparation of surface as per direction including providing necessary putty work, scaffolding etc complete with all labour and materials in all floors. Work should be executed as per manufacturer"s specification.
4Painting two or more coats of approved synthetic enamel paint over a coat of approved primer (Including) suitable as per manufacturer"s specification to achieve the desired finish over wall surface/wooden surfaces/other surfaces after preparation of surface properly as per direction with all labour and materials. The item is to be completed in all respects as per directions with all labour and materials.
5Joinery surface
6Steel surface
7Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). Sal Local. At any floor & any location.
8Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). 1st class Best Indian teak. At any floor & any location.
9Supplying, fitting and fixing boiling water proof ply conforming to IS: 710-1977 bonded with phenol formaldehyde synthetic resin conforming to IS: 848-1974 of approved make and brand fitted and fixed as per design as direction of Engineer-in-Charge. [excluding the cost of supporting frame work per approval and and teak wood batten/Lipping]At any floor & any location.
106mm
119mm
1212mm
1319mm
14Supplying, fitting and fixing boiling water resistant ply conforming to IS: 303- 1989 bonded with phenol formaldehyde synthetic resin of approved make and brand fitted and fixed as per design as per approval and direction of Engineer-in- Charge.At any floor & any location.
159mm
166mm
17Supplying, fitting & fixing of Aluminium fixed partion wall of all aluminium sections viz top, bottom and side member, intermediate member, glazing clip made of Aluminium Alloy Extrusions conforming to IS: 733-1983 and IS: 1285-1975, annodized conforming to IS:1868- 1983, fitted with all other accessories viz. EPDM gusket,cleat, angle screws etc. including labour charges for fitting and fixing of aluminium fixed partition wall with glass / panel board all complete as per architectural drawings and direction of Engineer-in-charge. (Excluding cost of glass/ panel board, 10-12 Micron thickness Annodizing film. Natural white.
18a) for unsupported length of vertical member upto 1.50m. height of both ends of vertical member restrained but panel with in 0.90 sqm
19b) For unsupported length of vertical member above 1.50m. height of both ends of vertical member restrained but panel above 0.90 sqm
20Providing and laying 50mm thick expanded polystyrene block (self extinguishing type) having density 34.00Kg/Cum, thermal conductivity 0.28 W/M-K, water absorption 0.1% (Maximum to be laid inside the partition wall by adhesive/fasteners as per manufacturers specification and specific direction, complete with all materials and labour.
21Partition of teak veneer as per design fitted and fixed complete (excluding the supporting frame work). 4mm thick commercial quality. At any floor & any location.
22Supplying solid flush type doors of deluxe decorative (both side) quality, conforming to I:S 2202 timber frame consisting of top and bottom rail and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 27.5mm wide battens places both ways in order to made the door of solid core and internal lipping with teak, mahogony or rose wood approved decorative veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing the shutters in position but excluding the cost of hinges and other fittings in any floor: (a) 35mm thick shutters (single leaf)
23Providing, fitting and fixing in position frameless fully glazed composite door fixed to the lintel and floor fitted with necessary SS Patch fittings with double action floor spring including providing 12 mm thick toughened float glass of special selected quality free from bubbles, holes or any surface deformation. Allow for cutting, chase to walls, lintel and floor and mending good damages. The rate shouldinclude for providing necessary approved qualitylocks, handles etc complete inall respects withnecessary patch fittings & fixtures, stainless steel pivot support as per drawing and direction with all labour and materials. a) Sliding/Swing (Door) with necessary top and bottom channles and slidders with a provision of movement sensor.(sensor to be paid separately).
24French polishing to wood work including preparing surface. High gloss polish with lacquer finish. On new wood work. At any floor & any location.
25Supplying fitting, fixing decorative lamination conforming to IS: 2046 : 1995 as per approved make, brand, finish and thickness with fitting, fixing the same on Particle/MDF / Ply Boards with recommended / approved adhesive with proper clipping the sides for better attachment as per direction of Engineer-incharge. The rate includes the cost of labour, adhesive and all incidental charges thereof. Glossy/Matt/Suede excluding surface texture or metallic lustre. Thickness of laminate 1 mm. At any floor & any location.
26Supplying, fitting and fixing 8mm thick Laminated wooden Flooring Work conforming to EN13329:2006 with plank size not Iess than 1200 mm X 190 mm (with unilin/tongue-groove locking arrangement) having 0.2mm thk top abrasive layer over a decorative layer followed by a High-density fibreboard (HDF) having density > 850 kg/m3 substrate core over a rasin saturated backing layer and installing through unilin or tongue- groove system (having locking strength not less than 1000 kg/m) over a 2 mm thk underlayer polyurethene foam on polythene sheet 250 micron, over a smooth, flat, hard subfloor free from moisture (< 8%), grease etc. complete in all respect with requisite accessories like end profile, transition profile, reducer "T" profile etc. wherever required and preparation of base including all other incidental works as per direction & satisfaction of Engineer in charge. Cost of Laminate Floor Accessories only (Skirting ,End edge, T- moulding,Reducer) shall have to be added separately, wherever required. Category: Normal Footfall; Class- 23;Abrasion resistance:-AC3 Thk on Swelling:- < 18% ;Impact resistance:- IC 1
27Providing and fixing of false ceiling with powder coated exposed G.I. grid suspension system (E-Grid U-1520 or equivalent load carrying capacity with mid span deflection not exceeding 1/360 span with hanger spacing of 1200mm c/c ) consisting of Main Runner 3600 mm long, Cross Tee 1200 mm / 600 mm long and Wall Angle. The Wall Angle shall be fixed on PVC Dash Fasteners on the perimeter of the wall by steel screws with distance 300mm c/c. The Main Runners to be placed @ 1200 mm. The Cross Tee 1200mm will be inserted in the pre-cut slots of Main Runner at a regular interval of 600 mm to form a modular grid of 1200mm X 600mm. Additional Cross Tees of 600 mm shall be placed perpendicular to the Cross Tee 1200 mm long to finally form a grid of 600 mm X 600 mm. Grid of module size 600 mm X 600 mm shall be supported by 6 mm diaG.I. wire from purlins / soffit. 15mm thick OW Acoustic Board (Mineral Fiber Acoustic Ceiling Tiles) of approved patern and size 595mm X 595mm with NRC value > 0.65 should be placed in the Grid module to form a False Ceiling. All complete as per the drawing & directions of Engineer-in-charge. In any floor.
28Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick)
29CHAIR Providing & installation of mid back chairs with mesh for back & seat in fabric, tilting back rest, fixed armrests with cantilever base and castor.
30Supply, fitting & fixing of magnetic lock. As per approved brand.
31Supply, fitting & fixing of cabinet lock. As per approved brand.
32Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws: 100mm long x 10mm dia. bolt. As per approved brand.
33Supplying, fitting and fixing SS hinge cleat in position excluding the cost hinge and other fiffitngs. 50mm
34Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. (i) 100mm. X 50mm. X 1.25mm.
35Supply, fitting & fixing of telescopic channel for drawer fixing purpose. As per approved brand.
36Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete. Without base. 100 mm grip x 10 mm dia rod. As per approved brand.
37Supply, fitting & fixing of autoclosing hinges for cabinet shutter. As per approved brand.
38Supply, fitting & fixing of venetian blind with necessary frame work for glass windows. As per approved brand.
39Hydraulic door closer of approved quality as per I.S.I. standard fitted and fixed complete. Godrej Hydraulic door closer fitted and fixed complete. Heavy type.
40Supplying, fitting & fixing Stainless Steel "D" or "H" type of size 300 mm x 19 mm tubular Handle with Grade 304, CE certified, marked & conforming to EN - 1154, of approved quality of reputed brand as per direction of Eingineer-in- Charge fitted and fixed complete including all incidental charges.
41Supply fitting & fixing of Door Stopper (Brass). As per approved brand.
42Supplying mortice lock chromium plated with keys 6 levers including fitting & fixing complete.
43Dismantling the existing false ceilingboards and its frame work and removing & stacking the same as per direction of onwer.
44Removing carefully existing plaster/skirting of any thickness as per direction from wall, ceiling etc including preparation of surface to receive new plaster, removing debris from work site. Complete with all labour and materials in all floors.
45Taking out carefully existing Partition with frame,aluminium doors , floor springs, loose furniture(cheir , table, cup boards, computer etc.),shiftring to 7th floor and stacking properly for re use . all surplus materials debrish shall be remove d at any suitable place as per direction of owner , payment will be made as per floor area
46Taking out carefully existing collapsible gate/grills and refixing the same in position after repairing and painting including preparation of surface the same as per direction to match with existing gate complete with all labour and materials.
47ELECTRICAL WORK
48MCB Distribution Board
49Supplying and fixing of surface/flush mounting double door Vertical TPN MCB Distribution board for MCB DB with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finsh incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. The rate shall include necessary civil work for installation as required.
50UP TO 160A
516 way Enclosure (LTVD06MGN)
52SIT & C of surface/flush mounting of double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. The rate shall include necessary civil work for installation as required.
534 way Enclosure (607715)
54SIT & C of surface/flush mounting of double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.
552+8 way Enclosure (607711)
56MCB
57Supplying and fixing 240/415V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection as required
586-32A SP
596-32A DP
606-32A TP
616-32A FP
6263A FP
63Surge Protective Device
64Supplying and fixing Class-2 (T2) 415V, FP Surge Protective Device (SPD) of Imax 40kA/pole mounted on din rail of existing DBs and necessary connection
65MCB Enclosure Box for AC ODU
66Supplying and fixing of 6-32A FP Isolator with metal enclosure (outdoor type-IP65) near AC ODU (concealed/surface) & mending good the damages to original finish including painting, connection & provision for earthing attachement.
67Supplying and fixing of 6-32A DP Isolator with metal enclosure (outdoor type-IP65) near AC ODU (concealed/surface) & mending good the damages to original finish including painting, connection & provision for earthing attachement.
68MV CABLE
69Supplying, laying, testing and commissioing of 1.1KV grade, A2XFY XLPE Armoured Aluminium cable of following size with all necessary accessories required for installation on the wall above false ceiling and concealed/surface on wall below the false ceiling, Rate shall include with 2 Nos. 10 SWG GI earth continuity Wire for running earth and all civil work like cutting dressing mending good damages as required.
704 core 25 sqmm
71Cable End Termination
72Supplying and fixing Double Compression type Gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE armoured cable as below:
734 core 25 sqmm
74Finishing the end of following XLPE armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make),tapes,anticorrosive paste & jointing materials:
754 core 25 sqmm
76SUB MAINS/CIRCUIT MAINS
77Wiring With PVC Insulated & Unsheathed Single Core Stranded Copper Wire ‘"FR" – in PVC Rigid/Flexible Conduit "FR" (ISI Marked) on wall/ceiling/Furniture as per site requirement (concealed / surface)
78Supplying & drawing of wiring in 11KV single core stranded "FR" PVC insulated & unsheathed copper wire in 20mm size PVC rigid/flexible conduit (as per direction by EIC) "FR" including neccessary Fittings and neccessary connections as required
792 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC.
802 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC.
81Supplying & drawing of wiring in 1.1 KV single core stranded "FR" PVC insulated & unsheathed copper wire in 25mm size PVC rigid/flexible conduit (as per direction by EIC) "FR" including necessary Fittings and necesaary connections as required
824 x 56/0.3 (4 sqmm) + 2 x 36/0.3 (2.5 sqmm) ECC.
834 x 84/0.3 (6 sqmm) + 2 x 56/0.3 (4 sqmm) ECC.
84Wiring With PVC Insulated & Unsheathed Single Core Stranded Copper Wire ‘"FR" – in PVC Casing-Cappingon wall/ceiling/Furniture as per site requirement
85Supplying & drawing of Wiring in 1.1 KV grade single core stranded "FR" PVC insulated & unsheathed copper wire of following sizes in 25mm PVC casing-capping (as per direction by EIC) including necessary PVC clips, fittings, necessary connections as required
862 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC.
87Point Wiring
88Supplying and carrying wiring for light, fan and dependent socket points by using 16 SWG MS/PVC conduits with threaded joints of required dia as per IS 732, MS/PVC conduit accessories, MS/PVC flexible conduit with couplers for drops with accessories, 2 x 1.5 + 1 x 1.5 sq mm, 1100V grade FRLS PVC insulated copper wires approved 6A modular type switches and sockets with plates and all accessories for fixing in modular furniture, GI/PVC boxes and other point wiring accessories and carrying out surface/concealed conduit system of wiring as per requirement with all wiring materials. Conduits shall run on surface of the ceiling above false ceiling and concealed in wall by cutting chase in wall and mending good of all the damages. All points shall be earthed with 1.5 sq mm FRLS flexible copper wire. Wires shall be terminated at light fixtures with ferrules, 16A, 4 way connector, wire ends shall not be kept loose/bare. The rate shall also include all accessories of MS/PVC conduits, etc, necessary civil works for embedding conduits and boxes below false ceiling, wherever applicable.
891 light point controlled by 1 no. 6A switch
902 light points controlled by 1 no. 6A switch
913 light points controlled by 1 no. 6A switch
92Fan point controlled by 6A switch & ceiling rose near fan
93Switches & sockets
94SIT & C of the following components like approved plate type modular switches, socket etc. duly wired.
951 No. - 6/16A, 6 pin in universal socket controlled by 16A, SP switch, RP in workstations and in cabins, with MS/PVC Box.
96Same as above but without MS/PVC Box
973 NOS - 6A, 5 pin socket controlled by common 16A, SP switch, workstations without MS/PVC Box
98Same as above but with MS/PVC Box
991 No. - 6A, 5 pin in universal socket controlled by 6A, SP switch, for Wi-fi with MS/PVC Box.
100AC Sockets & Starter
101Supply and flush fixing of modular type heavy duty plug socket unit comprising of 16/25A socket and plug top (with indicator) and solid state type starter units of electronic type with highflow voltage protections, O/L protect etc and suitable for AC Units modular type and completely wired including cutting chases and mending good damages, painting, earthing, neccessary connections complete, as per required for AC Units.
102Empty Conduits
103Supply and fixing of FRLS PVC (ISI marked) conduit (rigid/flexible) of various dia, exposed or concealed with all accessories like tees, bends, glands etc. JBs (PVC) as required and fish wire etc for wiring purpose complete and mending good damages to building works.
10420 mm dia (2 mm thick)
10525 mm dia (2 mm thick)
106Supplying and fixing PVC casing-capping on wall or ceiling, including elobw, necessary PVC fittings etc. amd mending good damages to building works
10720x10 mm Size
108Suplying and fixing of 5.5" x 5.5" Sheet Steel Cover on floor JB
109LIGHT & FAN FIXTURE WORK
110INDOOR TYPE LUMINAIRE
111Supply, installation, testing and commissioning of light fixture complete with all fittngs & accessories, as required. Erection rate shall include necessary GI chain and supporting suspending hardware for fixing the light fittings.
112Recessed mounted LED light fixture (PHILIPS RC380B LED36S-6500 G6 L60W60 PSU OD (FULLGLOW) OR SIMILAR APPROVED EQUIVALENT).
113Recessed mounted Down Light 20W round LED light fixture (PHILIPS DN296B LED20S-6500 PSU WH OR SIMILAR APPROVED EQUIVALENT).
114WALL MOUNTING FAN
115Supply, Installation, Testing & Commissioning of "Decorative Wall-Mounted" oscillating type fan with inbuilt speed controller. The rate shall be inclusive of fixing & mounting accessories and making necessary connections as required. Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length
116450mm Sweep wall fan. (HAVELLS AIRBOLL HI-SPEED OR SIMILAR APPROVED EQUIVALENT)
117Dismantling / Removal
118Dismantling / removal of existing light fittings, switch boards, conduit etc.
119CASSETTE TYPE SPLIT AC
120Supply, Installation, Testing & commissioning of Air Cooled Cassette, Non-Inverter Split Type Air Conditioning Machines of following cooling capacities with Rotary / Twin Rotary type compressor. The condenser will comprise of copper tube aluminium finned coil with safety controls and refrigerant gas - R32/R 410A gas as required.
1212.0 tr - 2 star
1223.0 tr- 2 star
123REFRIGERANT PIPING
124Supply and installation of soft drawn refrigerant piping for the Abovementioned Cassette A.C. Units including Nitryle Rubber Insulation.
125CABLING
126Supply and installation of electricalPower/ control cablingof suitable size between indoor units and outdoor units.
1274C X 2.5 mm
128DRAIN PIPING
129Supplying and laying of condensate drain line withPVC pipe complete with all accessories with 6mm Nitryle Rubber Insulation.
13025mm
13132 mm
132ODU STRUCTURE
133Supplying and installation of MS Fabricated ODU Angle (50x50x6 mm) structure for installation of Out door unit with all accessories including ribbed neoprene VI Pads, painting two coats with synthetic enamel paint over a coat of red oxide primer etc for Cassettes.
134Misc AC work including civil work for breaking wall for copper pipe, cable & drain water line, Scaffolding / Lifting etc and mending good damages complete.
135Dismantling of existing 17 Tr AC machine (IDU & ODU), AC pipes, ducts, diffusers, cables etc. and storing the same carefully as directed by E.I.C.
136FIRE WORK
137Dismantling carefully the existingfire sprinkler from old false ceiling, storing the same carefully and fixing the same in new false ceiling with necessary clamps etc. complete
138Dismantling carefully the existing smoke detector from old false ceiling, storing the same carefully and fixing the same in new false ceiling with necessary wire etc. complete.
139Supply and fixing Fire exit signage (i.e.,"FIRE EXIT") in aclyric sheet with vinyle painted with all accessories complete.size shall be 6"x12"
140Dismantling the existing 6W Speaker and reinstallation of the same in new false ceiling with necessary fittings as complete.
141SITC of 15 mm size Quartz Bulb type Fire Sprinkler of rating 68 Deg.C with required accessories. as complete.
14265 inch. interactive flat panel with trolly incl. Octacore Processor/ 8GB RAM / 32GB Storage / 2*16W Speaker / 3 Years Warranty / HDMI Cable / Display Adapter
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail