}

Tender For Repair To Path Hard Standing Cover Slabs Chain Link Fencing Etc At Certain Officers Md Accn Area And Repair Maintenance Of Central Package Type Ac Plants Under Ge I Gos, gopalpur-Odisha

Military Engineer Services-MES has published Tender For Repair To Path Hard Standing Cover Slabs Chain Link Fencing Etc At Certain Officers Md Accn Area And Repair Maintenance Of Central Package Type Ac Plants Under Ge I Gos. Submission Date for this Tender is 30-10-2023. General Hardware Tenders in gopalpur Odisha. Bidders can get complete Tender details and download the document.




Tender Notice

40114501
Tender For Repair To Path Hard Standing Cover Slabs Chain Link Fencing Etc At Certain Officers Md Accn Area And Repair Maintenance Of Central Package Type Ac Plants Under Ge I Gos
Open Tender
Indian
Odisha
gopalpur
30-10-2023

Tender Details

Tender For Repair To Path Hard Standing Cover Slabs Chain Link Fencing Etc At Certain Officers Md Accn Area And Repair Maintenance Of Central Package Type Ac Plants Under Ge I Gos

Key Value

Document Fees
INR 500 /-
EMD
INR 82000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work:REPAIR TO PATH, HARDSTANDING, COVER SLABS, CHAIN LINK FENCING ETC AT CERTAIN OFFICER"S MD ACCN AREA AND REPAIR/MAINTENANCE OF CENTRAL /PACKAGE TYPE AC PLANTS UNDER GE (I) GOS.
Sl. No. Item Description
1Demolition of Cement Concrete (unreinforced) of any description & in any position not otherwise specifically provided for. Complete all as specified & directed.
2S&F machine pressed precast concrete interlocking paver block any shape & size conforming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement & pigment complete all as specified & directed.
3M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
4M&L for 100 mm thick cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as sub base of floor complete all as specified and directed.
5M&L for hard core of gauge n exc 63 mm, deposited, spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surface all as specified and directed.
6M&L for cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in path/ hard standing surface finished even and fair complete all as specified and directed.
7M&L 75 mm thick cement concrete 1:3:6 type C2 using 40 mm graded stone aggregate as in sub base,floor , plinth protection etc and finishing cement concrete even and fair specified and directed by Engr - in - Charge.
8M&L Excavating over areas, n exc 1.5 m deep and getting out in soft/ loose soil complete all as specified and directed.
9M&L for providing Glass strip of 6 mm thick and 40 mm deep in hardstanding for making panels complete all as specified and directed.
10M&L for 10 mm thick heavy duty exterior designer tiles of size 300 mm x 300 mm as in floor set, jointed in neat cement slurry and pointed with grey cement and pigment complete all as specified and directed.
11M&L forscreed bed or bedding layer of mortar 15 mm thick in CM 1:4for laying floor finishes complete all as specified and directed.
12M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in sub base flooring average 25 mm thick surface finished even andrough (as in levelling course) to receive the topping layer complete all as specified and directed.
13Dismantling floor, hearth or wall tiling including cement mortar bedding etc (but not backing)and removing rubbish off the premises complete all as specified and directed.
14S&F in repairs 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed
15S&F in repairs 110mm bore PVC (SWR) bends any radius complete all as specified and as directed
16Demolition of RCC of any description and in any position not other wise specially provided for reinforcement cut as required to facilitate demolition complete all as specified and directed.
17M&L for pre cast cement concrete 1:1.5:3, type A-1, using 20mm graded stone aggregateas in cover slabs (for manholes etc) and similar articles with plain faces, set in CM 1:4 complete all as specified and directed.
18M&L for Mild SteelTMT bar 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
19M&L for finishing cement concrete even and smooth using extra cement complete all as specified and directed.
20Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
21M&L Brick work using fly ash bricks straightor curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
22M&L for rendering 15mm thick in CM 1:6 on brick or concrete surface, finishing even and smooth without using extra cement complete all as specified and directed.
23M&L for Returning, filing in, including spreading, levelling, watering and well rammingin layers not exceeding 25 cm in any type of soil etc complete all as specified and directed
24M&L for Removing excavated material (Soil) exc. 250 m but n exc. 500 m and depositing where directed complete all as specified and directed.
25Taking down cement plaster on brick or concrete surface including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
26M&L for preparing new plastered surfaces of walls and applying three coats of white wash complete all as specified and directed
27Dismantling posts or sturts (wood,steel or RCC) any section incl taking out embedded portion and making good disturbed ground etc all as specified and directed.
28Dismantling fencing wire mesh any type etc all as specified and directed.
29Excavating in post holes (or similar holes) each n.exc 0.5 cum getting outmaking good the disturbed surface if required in soft/ loose soil complete all as specified and directed.
30M&L for PCC 1:3:6 Type C-2 using 40 mm graded stone aggregate in foundation filling and mass concrete all as specified and directed.
31S&F Angle iron posts and rails,drilled and struts in fencing including cutting tops to shape as directed, driiling holes, notching for wire, etc, flat iron fillets (for secruing wire mesh etc) including all necessary drilling, bolting or riveting, etc and similar work conforming to Fe-290 Gde E-165.
32Mild Screw bolts (Machine made) with hexagonal or square head at one ends andto fitted with washers and one hexagonal or square n.exc 15cm long, dia of neck 11 to 15mm all as specified and directed by Engr-in-Charge.
33S&FPVC coated chain link of 3.16mm dia mild steel galvanised fencing of mesh size 100 mmx 100 mm as per IS : 2721-2003 weight n exc 4.00 kg per sqm complete all as specified and directed by Engr - in - Charge.
34S&F mild steel round bars 10mm dia and over, cut to length, bent to shape required, includingcranking, bending spirally for hooping for columns, hooking endsand binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality conforming to Fe-410-W (Gde E-250) quality-A or Fe-290 (Gde-E-165) complete all as specified & directed.
35M&L for preparation of old surface by scraping and smoothing the surface with water emery paperandpainting with approved colour of synthetic enemelled paint of two coat over a coat of primer red oxide and writing letters/numbers(SM/MES Nos.) ofCompressor with motor, foundation frame, including foundation of A/c plants of capacities 30 to 33 TR and cleaning the surrounding area up to three metre out side area of the plant by cutting grasses and surface dressing including white wash of plantroom complete all as specified and directed by Engineer in charge.(Note: The arrangement ofmen power,T&P and necessary items shall be contractors responsibility)
36All as peritemNo 35 above butCondenser assembly of AC plant of capacity 30 to 33 TR.
37All as per item No 35 above butCondenser water pump with motor, foundation frame and including foundations, rubber washers,glands, nuts, bolts and washers of AC plant of capacity 30 to 33 TR
38All as per item No 35 above butexposed water circulation and gas circulations pipe lines including marking direction of flow of AC plant of capacity 30 to 33 TR.
39All as per item No 35 above but Cooling tower cleaning with proper cleaning agents twise in the contract periodwithout any damages in cooling towers complete of AC plant of capacity 30 to 33 TR
40All as per item No. 35 above but for 22/30 TR capacity A/C plant complete all as specified and directed as Compressor with motor, foundation frame including foundation.
41All as per item No 35 above butCondenser assembly of AC plant of capacity 22/30 TR.
42All as per item No 35 above butCondenser water pump with motor, foundation frame and including foundation rubber washers,glands, nuts, bolts and washers of AC plant of capacity 22/30 TR.
43All as per item No 35 above butExposed water circulations and gas circulates pipe lines including marking direction of flow of AC plant of capacity 22/30 TR.
44All as per item No 35 above butCooling tower complete of AC plant of capacity 22/30 TR.
45M&L for replacement of cast iron sluice valve with stainless steel spindles with flanged ends duly ISI marked confirming to IS 780 part1, PN 1 type complete suitable as per exiting AC plant for the 100 MM bore sizes complete all as specified and directed.:- Make: Kirloskar /RMCO / Upadhiya
46All as per item No 45 above but 80 MM bore
47All as per item No 45 above but 65 MM bore
48Taking down old unsv butterfly valve from existing location and supply and fixing new butterfly valve of size 100 mm dia and including necessary pipe fittings nuts,bolts,washers and rubber washers etc complete all as specified and directed Make:- Kirloskar/L&T/Amco industrial valves/RMCO/Upadhiya
49All as per item No.48 above but size 80 mm dia.
50All as per item No.48 above but size 65 mm dia.
51All as per item No.48 above but size 50 mm dia.
52Taking down old unsv Non return valve from existing location and supply and fixing new non return valveof size 100 mm dia and including necessary pipe fittings, nuts,bolts,washers and rubber washers etc complete all as specified and directed Make:- Kirloskar/L&T/Amco industrial valves/RMCO/Upadhiya
53All as per item No.52 above but size 80 mm dia.
54All as per item No.52 above but size 65 mm dia.
55All as per item No.52 above but size 50 mm dia.
56Taking down old unsv Non return butterfly valve from existing location and supply and fixing new non return butterfly valve valve of size 100 mm dia and including necessary pipe fittings, nuts,bolts,washers and rubber washers etc complete all as specified and directed Make:- Kirloskar/L&T/Amco industrial valves/RMCO/Upadhiya
57All as per item No.56 above but size 80 mm dia.
58All as per item No.56 above but size 65 mm dia.
59All as per item No.56 above but size 50 mm dia.
60Taking down old unsv pipe line from existing loaction and supply and fixing new MS ERWheavy duty pipe of size 100 mm dia with fittinmgs and including providing necessary fabrication,welding work and accessoriesnuts,bolts and washers complete all as specified and directed.
61All as per item No.60 above but size 80 mm dia.
62All as per item No.60 above but size 65 mm dia.
63All as per item No.60 above but size 50 mm dia.
64Taking down old unsv pipe line from existing loaction and supply and fixing new GIheavy duty pipe of size 100 mm dia with fittings and including providing necessary fabrication,welding work and accessoriesnuts,bolts and washers complete all as specified and directed.
65All as per item No.64 above but size 80 mm dia.
66All as per item No.64 above but size 65 mm dia.
67All as per item No.64 above but size 50 mm dia.
68All as per item No.64 above but size 40 mm dia.
69All as per item No.64 above but size 32 mm dia.
70All as per item No.64 above but size 25 mm dia.
71Taking down old unsv gate valves from existing loaction and supply and fixing new gate valve of size 100 mm dia with necessary accessoriesnuts,bolts and washers complete all as specified and directed.
72All as per item No.71 above but size 80 mm dia.
73All as per item No.71 above but size 65 mm dia.
74All as per item No 71 above but size 50 mm dia.
75All as per item No.71 above but size 25 mm dia.
76Taking down old unsv strainer for suction from existing loaction and supply and fixing new strainer of size 150 mm dia with necessary accessoriesnuts,bolts and washers complete all as specified and directed.
77All as per item No.76 above but size 100mm dia.
78M&L for Dismantling and removing defective fins of FRP type cooling tower and supply and fixing new PVC finsbrick containing suitable for existing cooling tower system, eleven layers size of brick 600 mm x 300 mm x 150 mm complete all as specified and directed.
79M&L for dismantling and removal of old unserviceable motor and Supply and fixing in replacement of cooling tower fan motor(induction motor) of capacity 3 HP, 415 V as per site conditions/suitable and incl providing necessary shaft key,shaft,nuts,bolts and wahsers complete all as specified and directed. Note- Old u/s motor to be deposite in AGE E/M store.(Note: The arrangement ofmen power,T&P, settings shall be contractors responsibility)
80M&L for dismantling and removal of old unserviceable motor and Supply and fixing in replacement of cooling tower fan motor(induction motor) of capacity 5 HP, 415 V as per site conditions/suitable and incl providing necessary shaft key,shaft,nuts,bolts and wahsers complete all as specified and directed. Note- Old u/s motor to be deposite in AGE E/M store.(Note: The arrangement ofmen power,T&P, settings shall be contractors responsibility)
81Opening of shell and tube condensor end covers for inspection, pressure testing for leakage detection of condensor and identification of leakage, arresting the same with brazing, pressure testing after repairs, reassembling of end covers including cost ofrubber gasket and making water connections, testing and commissioning to the entire satisfaction of Engineer-in-charge complete all as specified. (Note: The arrangement ofmen power,T&P, Nitrogen gas,welding eqpts shall be contractors responsibility)
82M&L for dismantling and removal of old unserviceable chilled water tank and S & F in replacement of chilled water storage tank stainless steel with installation for AC plant as per existing size and specification complete all as specified and directed.
83M&L for dismantling and refixing after proper alignment with & including providing new belt,nut bolt and fixing accessories for fan & motor of cooling tower of AC plant complete all as specified and directed.
84S&F in replacement blower shaft both end bearing with casing self revolving type NTN P-207 as per existing complete all as specified and directed by EIC
85Supply and fixing in replacement cooling tower fan with hub as per sample of existing size as directed by Enigneer-in-charge.
86M&L for dismantling and removal of old unserviceable motor and S & F in replacement of blower motor of capacity 20 HP, 415 V with installation for AC plant as per existing specification and conditions complete all as specified and directed. Note- Old u/s motor to be deposite in AGE E/M store.
87Supply and charging refrigerant gas R-22 complete all as specified and directed. Make: Mafron
88Taking out / purging of refrigerant gas from the system of A/c plant 1 x 30/33 TR capacity carrying out vacuum test by vacuuming the whole A/c plant with the help of vacuum pump and checking the complete system for leakages. Carrying out the pressure test by chargingthe nitrogen gas in the system and checking of any leakagepoint , repair / rectification of the same and removing the nitrogen gas from the system and charging of refrigerant gas including charging of additional gas as required and complete all as specified and directed. (Note: The arrangement ofmen power,T&P and Nitrogen gas shall be contractors responsibility)
89All as per item No. 55 above for 1 x 12.5/22 TRunit of A/c plant, complete all as specified and directed.
90S & F in repairs thermostat expansion valve suitable for 12.5 to 33 TR complete all as specified and directed. (Make: Sporlan / Alco)
91S & F in repairs water temparature sensor suitable for 12.5 to 33 TR complete all as specified and directed. (Make: as per existing model and make or suitable any other approval)
92M&L for dismantling and removal of old unserviceable condensor coil and S&F in replacement condensor coil for 5.5 TR capacity condensor as per existing site requirement for package type AC plant complete all as specified and directed.
93Supply and fixing in replacement ofliquid line stainer filter for SMC-6-65/SMC-4-100 complete all as specified and directed.
94Supply and charging of compressor oil complete all as specified and directed.
95M&L for dismantling and removal of old unserviceable motor with pump and S&F in replacement monoblock pump motor of capacity 10 HP, 415 V as per site requirement and conditions for AC plant complete all as specified and directed and Old u/s pump motor to be deposite in AGE E/M store. (Note: The arrangement ofmen power,T&P, settings shall be contractors responsibility)
96M&L for descaling ofthe entire water circulating system for central AC plant water cooled of capacity upto 3 x 33 TR along with condensers, cooling tower/piping pumps etc.Opening condenser by disconnecting nut bolts and cleaning withMAIC descalingsolution with help of descaling pump/wire brush, cleaning rod etc circulating above solutionin condenser pipe lines as required time, flushing out the complete solution from condensers pipe line by fresh water with pressure.Re-assembling by replacement of unserviceable nut bolts washers gaskets etc all as specified and directed.Note:- cleaning and descaling shall be carried out by pump with acid as required to keep head pressure within safe limit. If any damage during cleaning/descaling repair shall be carried out by contractor without any extra cost. (Note: The arrangement ofmen power,T&P, settings by mechanicshall be contractors responsibility)
97M&L for clean the filter & cooling coil, gas leakage testing and electrical fault detection of any kind for package type AC plant of capacity 4.5/5 TR complete all as specified and directed.
98M&L for clean the filter & cooling coil, gas leakage testing and electrical fault detection of any kind for package type AC plant of capacity 10/13.5 TR complete all as specified and directed.
99Checking of air conditioning plant water cooled any size , capacity and location forfunctioning of motors, condenser , blower fan motors , unusual noise,refrigerant standing pressure and nut bolt washers etc including testing for smooth functioningand inform Engr in Chargefor repair if required complete all as directed by Engr-in-charge.(Note: The arrangement ofmen power,T&P, settings by mechanic shall be contractors responsibility)
100S&F in repair fan belt No C-112 complete all as specified and directed, Make- FENNER or equivalent
101S&F in repair fan belt No B-86 complete all as specified and directed, Make- FENNER or equivalent
102S&F in repair fan belt No C-108complete all as specified and directed, Make- FENNER or equivalent
103S&F in repair fan belt No B-66complete all as specified and directed, Make- FENNER or equivalent
104S&F in repair AHU V belt No B-104complete all as specified and directed, Make- FENNER or equivalent
105S&F in repair fan belt No PB82Bcomplete all as specified and directed, Make- FENNER or equivalent
106S&F in repair AHUAir filter 20 micronof size 20""x20""x2"" complete all as specified and directed
107Dismantling complete Accel Compressor set Model SMC-4-100 of 33 TR Capand overhauling the compressor with repairand checking ofwornout holes of studs and providing over size studs with nuts & washers and gaskets .Rematlling and balancing of piston,replacement of piston ring,scrapper ring, split pin, castle nut, connecting rod bolt ,bushing for piston pin, and set of sealing ring of compressor and refitting the same after the repair/replacement duly all as specified and tested for smooth functioning of model SMC-4-100 complete all as specified and directed by Engr-in-charge. (Note-1:The all spare parts are measured and paid separately in relevent items) (Note-2: The arrangement ofmen power,T&P, settings by mechanic and testing shall be contractors responsibility)
108S&F in repair for compressor set Model No SMC-4-100 suction valve ring plate 1.2mm
109S&F in repair for compressor set Model No SMC-4-100 Discharge valve ring plate 1.20mm
110S&F in repair for compressor set Model No SMC-4-100 Safty valve assembly
111S&F in repair for compressor set Model No SMC-4-100 connecting rod bolt
112S&F in repair for compressor set Model No SMC-4-100 Castle nut
113S&F in repair for compressor set Model No SMC-4-100 Split pin
114S&F in repair for compressor set Model No SMC-4-100 Half section of BRGSTD
115S&F in repair for compressor set Model No SMC-4-100 Bushing with collar STD
116S&F in repair for compressor set Model No SMC-4-100 Shaft seal including 10 A-G
117S&F in repair for compressor set Model No SMC-4-100 Piston with pin and rings
118S&F in repair for compressor set Model No SMC-4-100 Piston ring
119S&F in repair for compressor set Model No SMC-4-100 Scrapper ring
120S&F in repair for compressor set Model No SMC-4-100 Bushing for piston pin
121S&F in repair for compressor set Model No SMC-4-100 Valve spring
122S&F in repair for compressor set Model No SMC-4-100 Spring for unloading ring
123S&F in repair for compressor set Model No SMC-4-100 Set of GasketASL-1453
124S&F in repair for compressor set Model No SMC-4-100 Set of sealing ring
125S&F in repair for compressor set Model No SMC-4-100 Set of Neoprene Oring
126S&F in repair for compressor set Model No SMC-4-100 Cylinder W/O suction valve (R-22)
127S&F in repair for compressor set Model No SMC-4-100 Gasket F-10
128S&F in repair for compressor set Model No SMC-4-100 Gasket F-12
129S&F in repair for compressor set Model No SMC-4-100 Seeger ring
130S&F in repair for compressor set Model No SMC-4-100 GasketB-05
131S&F in repair for compressor set Model No SMC-4-100 GasketL-17
132S&F in repair for compressor set Model No SMC-4-100 Liquid line stainer (R-22)
133S&F in repair for compressor set Model No SMC-4-100 Pilot control solenoid valve
134S&F in repair for compressor set Model No SMC-4-100 Expansion valve
135S&F in repair for compressor set Model No SMC-4-100 Hand shut off valve
136S&F in repair shaft seal assembly of compressor of ACCEL make Model SMC -4-100 complete all as specified and directed
137S & F in repair of Sprinkler system for cooling tower complete all as specified and directed.
138S&F in repair shaft seal assembly SMC 6-65 complete all as specified and directed
139M&L in repairs to the cooling tower of 2 x 30/33 TR capacity by replacing the rusted GI wire mesh of existing gauge and weight of size 1.075Mx0.60x04 Nos with clamps, nuts and bolts etc complete all as specified and directed.
140S&F in replacement fresh air grill of size 600mmx350mm having wire mesh, closing/opening dampers of suitable size with handle of PGI sheet of 20 gauge complete all as specified and directed.
141S & F in replacement of Battery 12Volt 180 AH with initial charging maintenance free suitable for DG Sets complete all as specified and directed. Make- EXIDE EXPRESS or Equivalent
142S & F in replacement of Battery 12Volt 150 AH with initial charging maintenance free suitable for DG Sets complete all as specified and directed. Make- EXIDE EXPRESS or Equivalent
143Supply and charging refrigerant gas R-404/R-407, complete all as specified and directed. Make: Mafron
144Dismantling the power supply of electric motor any type including dismantling from pump and taking to workshop with necessary transportation and opening the complete motor and rewinding the rotor with super enameled copper wire as per the existing gauge with necessary insulation, sticks and varnishing, including replacement of shaft bearing 02 Nos complete of capacity 20 to 30HP complete all as specified and directed. (Note-1: The arrangement ofmen power,T&P,transport and testing shall be contractors responsibility)
145All as per item No.144 above but of capacity5 to 7.5 HP electric motor any type complete all as specified and directed.
146All as per item No. 144 above but of capacity10 to 15 HP electric motor any type complete all as specified and directed.
147All as per item No.144 above but 1 to 3 HP electric motor any type complete all as specified and directed.
148Dismantling complete Centrifugal /Mono Block pump set of any type and overhauling the pump re-threading of wornout holes of studs and providing over size studs with nuts & washers.Rematlling and balancing of shaft, replacement of gunmetal bush bearing and gland packing,nuts,bolts,washres,rubber gasketsof pump set.and refitting the same after the repair/replacement duly all as specified and tested for smooth functioning of capacity 10 to 15 HP complete all as specified and directed.(Note-1: The arrangement ofmen power,T&P,transport and testing shall be contractors responsibility)
149All as per item No 148 above but capacity 5 to 7.5 HP complete all as specified and directed.
150M&L for clean the fin & tank with acid/bleaching powder, tightening of nut bolt and clean the strainer of cooling tower of AC plant of any capacity complete all as specified and directed.
151Supply and fixing in replacement of MCB 32 Amp TPNAC, 415 volts, 10 KAs complete all as specified and directed. Make : Legrand/HAVELLS/ L&T/C&S.
152Supply and fixing in replacement of MCB 40 Amp TPNAC, 415 volts, 10 KA s complete all as specified and directed. Make ; Legrand/HAVELLS/ L&T/C&S.
153Supply and fixing in replacement of MCB 25 Amp TPNAC, 415 volts, 10 KA s complete all as specified and directed. Make ; CG/HAVELLS/ L&T/C&S.
154Supply and fixing in replacement of MCB 10 Amp TPNAC, 415 volts, 10 KA s complete all as specified and directed. Make ; Legrand/HAVELLS/ L&T/C&S.
155Supply and fixing in replacement of MCB 63Amp TPNAC, 415 volts, 10 KA s complete all as specified and directed. Make ; Make ; Legrand/HAVELLS/ L&T/C&S.
156Supply and fixing in replacement of moulded case circuit breaker panel mounting type , AC, 415 volts,16 KA of capacity 63amps 4 pole complete all as specified and directed. Make ; Legrand/HAVELLS/ L&T/C&S.
157Supply and fixing in replacement of moulded case circuit breaker panel mounting type , AC, 415 volts, 25 KA of capacity 100 amps 3 pole complete all as specified and directed. Make ; Legrand/HAVELLS/ L&T/C&S..
158Supply and fixing in replacement of moulded case circuit breaker panel mounting type , AC, 415 volts, 35 KA of capacity 125 amps3 pole complete all as specified and directed. Make ; Legrand/HAVELLS/ L&T/C&S.
159Supply and fixing in replacement of moulded case circuit breaker panel mounting type , AC, 415 volts, 36 KA of capacity 250 amps 4 pole complete all as specified and directed. Make ; Legrand/HAVELLS/ L&T/C&S.
160Supply and fixing in replacement of moulded case circuit breaker panel mounting type ,AC, 415 volts, 50 KA of capacity400 amps 4 pole complete all as specified and directed. Make ; Legrand/HAVELLS/ L&T/C&S.
161M&L for clean the filter, cooling coil & blower of AHU for AC plant of any capacity complete all as specified and directed.
162Taking down old unserviceable AHU complete cooling coil assembly from existing location and checking of water leakages in AHUcooling coilmaking repairs by brazing, gas welding,necessary copper tubes, copper jointing rods, joints etc after refixing the same its location properly and carry out the pressure testing after repairs of AHU for AC plant of any capacity complete all as specified and directed. (Note-1: The arrangement ofmen power,T&P,transportations etc and testingcomplete job shall be contractors responsibility)
163Supply and fixing in replacement ofPower contactor , 4Pole ,440v,50Hz ,400amp, : MNX 400 2 NO+2 NC complete all as specified and directed.Make: L&T/C&S/Havells
164Supply and fixing in replacement Contactor, 3poles with AC coil of MNX265 amps capacity complete all as specified and directed.Make: L&T/C&S/Havells
165Supply and fixing in replacement Contactor, 3poles with AC coil ofMNX225 amps capacity complete all as specified and directed.Make: L&T/C&S/Havells
166Supply and fixing in replacement Contactor, 3poles with AC coil ofMNX185 amps capacity complete all as specified and directed.Make: L&T/C&S/Havells
167Supply and fixing in replacement Contactor, 3poles with AC coil ofMNX70 amps capacity complete all as specified and directed. Make: L&T/C&S/Havells
168Supply and fixing in replacement Contactor, 3poles with AC coil ofMNX50 amps capacity, complete all as specified and directed.Make: L&T/C&S/Havells
169Supply and fixing in replacement Contactor, 3poles with AC coil ofMNX45 amps capacity, complete all as specified and directed.Make: L&T/C&S/Havells
170Supply and fixing in replacement Contactor, 3poles with AC coil ofMNX40 amps capacity, complete all as specified and directed. Make: L&T/C&S/Havells
171Supply and fixing in replacement Contactor, 3poles with AC coil ofMNX32 amps capacity, complete all as specified and directed. Make: L&T/C&S/Havells
172Supply and fixing in replacement Contactor, 3poles with AC coil ofMNX25 amps capacity, complete all as specified and directed. Make: L&T/C&S/Havells
173Supply and fixing in replacement Contactor, 3poles with AC coil ofMNX18 amps capacity, complete all as specified and directed. Make: L&T/C&S/Havells
174Supply and fixing in replacement of temperature gauge (thermometer) digitaltype 0-50 degree centigrade complete all as specified and directed.
175Supply and fixing in replacement ofcontrol switches pressure gauge low pressure (LP) complete all as specified and directed.
176Supply and fixing in replacement ofcontrol switches pressure gauge Highpressure (HP) complete all as specified and directed.
177Supply and fixing in replacement of HRC Fuse unit 400 Ampscomplete all as specified and directed.Make L& T /Havells /C&S
178Supply and fixing in replacement of HRC Fuse unit 200 Amps complete all as specified and directed. Make L& T /Havells /C&S
179Supply and fixphase failure preventor for the protection motorscomplete all as specified and directed. Make L& T /Havells /C&S
180Supply and fixing in replacement Aluminium lugs suitable for above 120 sqmm upto 240sqmm cable complete all as specified and directed. Make: Dowells/C&S /Havells
181Supply and fixing in replacement Aluminium lugs suitable for upto 120 sqmm cable complete all as specified and directed.Make: Dowells/C&S /Havells
182Supply and fixing in replacement thermal over load relay of range 6.5 to 10 Amps complete all as specified and directed Make- CG/L&T/ BCH/C&S.
183All as per item No 182above but 15 to 22 Amps capacity complete all as specified and directed.
184All as per item No 182 above but 30 to 50 Amps capacity complete all as specified and directed.
185All as per item No 182 above but above 50 to 70 Amps capacity complete all as specified and directed.
186All as per Item No. 182abovebut above 70 to 100 Amps complete all as specified and directed.
187Supply and fixing in replacement of indicating lamp set (RYB) LED type complete all as specified and directed.
188S&F in replacement Star Delta Timer 0-30 Seconds duration complete all as specified and directed. make L&T/Havell"s/C&S
189Supply and fixing in replacement of electronic adjustable cyclic timer complete all as specified and directed.Make : EAPL /L&T/Minilec.
190Supply and fixing in replacement industrial water pressure switch meter as per existing complete all as specified and directed.
191Supply and fixing in replacementof On off push bottonswitch electrical complete all as specified and directed.
192Supply and fixing in replacement Voltmeter digital type (0-500V) complete all as specified and directed. Make : AE/L&T/HPL
193Supply and fixing in replacement Ammeter digital type (0- 100 Amps) complete all as specified and directed. Make : AE/L&T/HPL
194S&F in repair Rotary selector switch 3 position complete all as specified and directed. Make : C&S/kaycee
195Supply and fixing in replacement CT Coil 100/5 Amps complete all as specified and directed. Make : L&T/AE/C&S
196Supply and fixing in replacement CT Coil 60/5 Amps complete all as specified and directed. Make : : L&T/AE/C&SL&T/AE/C&S
197Supply and fixing in replacement CT Coil 30/5 Amps complete all as specified and directed. Make : L&T/AE/C&S
198M & L for ladder of GI Pipe heavy 40 mm dia for cooling tower approx 6 mtr length complete all as specified and directed.
199M&L in renewal for making of computerised colour/ printed of layout plan or brief details i.e history of installation/ machinery of various installations on and including1.0mm thick plastic laminated acrylic sheet of size 1500x1200mm fixed to new hard boards with & including PVC beading of suitable size fixed to all edges of board with & including mild steel screws of suitable size complete all as specified and directed. Note:- Details i.e layout plan and brief details shall be provided by Engineer-in-Charge separately during execution.
200M&L in renewal for making of computerised colour/ printed of name of installation and details of various installations on and including1.0mm thick plastic laminated acrylic sheet of size 1000x600mm fixed to new hard boards with & including PVC beading of suitable size fixed to all edges of board with & including mild steel screws of suitable size complete all as specified and directed. Note:- Name & details of installations shall be provided by Engineer-in-Charge separately during execution.
201M&L for Repairs to cooling tower of 12.5/22 TR by replacing the rusted GI Wire mesh of existing gauge and weight of size nuts ,clamps,and bolts etc complete all as specified and directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail