Tender For Improvement Of Existing Toilet Block Of 120 Men Barrack No 01 And 03 At Bn Hq Of 121 Bn Bsf Madhopur Under Sector Bsf Gurdaspur (Sh- Iei And Service Connection), Gurdaspur-Punjab

Border Security Force-BSF has published Tender For Improvement Of Existing Toilet Block Of 120 Men Barrack No 01 And 03 At Bn Hq Of 121 Bn Bsf Madhopur Under Sector Bsf Gurdaspur (Sh- Iei And Service Connection). Submission Date for this Tender is 14-10-2023. Barrack Tenders in Gurdaspur Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

40103796
Tender For Improvement Of Existing Toilet Block Of 120 Men Barrack No 01 And 03 At Bn Hq Of 121 Bn Bsf Madhopur Under Sector Bsf Gurdaspur (Sh- Iei And Service Connection)
Open Tender
Indian
Punjab
Gurdaspur
14-10-2023

Tender Details

Improvement Of Existing Toilet Block Of 120 Men Barrack No 01 And 03 At Bn Hq Of 121 Bn Bsf Madhopur Under Sector Bsf Gurdaspur (Sh- Iei And Service Connection)

Key Value

Document Fees
Refer document
EMD
INR 3000.0 /-
Tender Value
INR 1.49 Lakhs /-

BOQ Items

Name of Work: Improvement of Existing Toilet Block of 120 Men BarrakNo 01 & 03at BN HQ of 121 Bn BSF Madhopur under sector BSF Gurdaspur (SH- IEI & Service Connection).
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group A
2Rewiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required Group A
3Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
4Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. A) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
5Supplying and drawing following sizes of FRLS PVC insulatedcopper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. i) 3 x 1.5 sq. mm
6Supplying and drawing following sizes of FRLS PVC insulatedcopper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. Ii) 3 x 4 sq. mm
7Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required (i)20 mm
8Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required (ii)25 mm
9Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required (iii)50 mm
10Supplying and fixing following modular switch/ socket on theexisting modular plate & switch box including connections but excluding modular plate etc. as required (i) 5/6 Amp. Switch
11Supplying and fixing following modular switch/ socket on theexisting modular plate & switch box including connections but excluding modular plate etc. as required (ii) 3 pin, 5/6 Amp. Socket Outlet
12Supplying and fixing following modular switch/ socket on theexisting modular plate & switch box including connections but excluding modular plate etc. as required (iii) 15/16 A switch
13Supplying and fixing following modular switch/ socket on theexisting modular plate & switch box including connections but excluding modular plate etc. as required (vi) 6 pin 15/16 A socket outlet
14Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. (i) 3 Module (100mmX75mm)
15Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. (ii) 6 Module (200mmX75mm)
16Supplying and fixing 3 pin,5 A ceiling rose on the existing junction box / wooden block i/c connection etc as required.
17Supplying and fixing 5 A to 32 A rating 240/415 volts,"C" curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections testing and commissioning etc as required. i) Single pole
18Supplying and fixing 5 A to 32 A rating 240/415 volts,"C" curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections testing and commissioning etc as required. Ii) Double pole
19Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). i).6 way , Double door
20Providing and installation of heavy duty exhaust fan (metal body) 380 mm sweep, 1400 RPM in the existing opening, including s/f of suitable size of louver / shutter & making good the damage, connection, testing, commissioning etc. as required.
21Supply, installation, testing and commissioning of 20 watt LED battan fittings complete with all accessories and LED tube directly on ceiling/ wallincluding connection with 1.5 sq. mm FRLS PVC insulated copperconductor single core cable etc as required.
22Supply and fixing of 10 Watt LED battan surface mounted with integrated electronic driver in ceiling/surface complete with all accessories including connections etc. as required.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail