Tender For Comprehensive Maintenance Of Fire Alarm Cum Gas Supression System For Old New Server Room Repair Maintenance Of Fire Fighting Equipments And Connected Works Installed At Dipac Under Ge U P And M Delhi Cantt 10, delhi-Delhi

Military Engineer Services-MES has published Tender For Comprehensive Maintenance Of Fire Alarm Cum Gas Supression System For Old New Server Room Repair Maintenance Of Fire Fighting Equipments And Connected Works Installed At Dipac Under Ge U P And M Delhi Cantt 10. Submission Date for this Tender is 03-11-2023. Fire Alarm Systems Tenders in delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

40060732
Corrigendum : Tender For Comprehensive Maintenance Of Fire Alarm Cum Gas Supression System For Old New Server Room Repair Maintenance Of Fire Fighting Equipments And Connected Works Installed At Dipac Under Ge U P And M Delhi Cantt 10
Open Tender
Indian
Delhi
delhi
03-11-2023

Tender Details

Comprehensive Maintenance Of Fire Alarm Cum Gas Supression System For Old New Server Room Repair Maintenance Of Fire Fighting Equipments And Connected Works Installed At Dipac Under Ge U P And M Delhi Cantt 10

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 27-Oct-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 03-11-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 61040.0 /-
Tender Value
INR 30.52 Lakhs /-

BOQ Items

Name of Work: COMPREHENSIVE MAINTENANCE OF FIRE ALARM CUM GAS SUPRESSION SYSTEM FOR OLD/ NEW SERVER ROOM & REPAIR/ MAINTENANCE OF FIRE FIGHTING EQUIPMENTS AND CONNECTED WORKS INSTALLED AT DIPAC UNDER GE(U) P&M DELHI CANTT-10.
Sl. No. Item Description
1Taking down Fire extinguishers of the following capacities from it"s location checking thoroughly, repair the same if any deffect is found, and taken out the parts and replacement of burnout parts like pressure guage, Squeese Grip Valve, Brass valves, Bend horn, Brass cap etc.and refilling the extingushing agent at workshop after emptying the extingushing agent where directed and place the Fire extinguisher at their original location complete all as specified and as directed by Engr-in-Charge. Note:- 1.Cost of the Extinguisher agent for refilling and transportation to workshop and back to DIPAC to be included in the quoted rate. 2. Cost of removing burntout and refixing new spares of Pressure guage, Squeese Grip Valve, Brass valves, Bend horn, Brass cap etc shall be included in the quoted rate but Cost of Material for these items shall be measured and paid seperately as "Supply Only" items.
2Fire Extinguisher Liquid type stored pressure type of capacity 9.0 Ltrs
3Fire Extinguisher AFFF mechanical form stored pressure type of capacity 09 Kgs
4Fire Extinguisher foam catrege type of capacity 09 Ltrs
5Fire Extinguisher CO2 type of capacity 4.5 Kgs
6Fire Extinguisher CO2 type of capacity 2.0 Kgs
7Fire Extinguisher Water CO2 type of capacity 4.5 Kgs
8Fire Extinguisher ABC Dry Powder type of capacity 1.0 Kgs
9Fire Extinguisher ABC Dry Powder type of capacity 2.0 Kgs
10Fire Extinguisher ABC Dry Powder type of capacity 5.0 Kgs
11Fire Extinguisher Powder type gas Catridge of capacity 9.0 Kgs
12Supply only Pressure Guage for any type of Fire extinguisher
13Supply only Squeeze Grip Valve for Dry Powder Fire extinguisher of any capacity
14Supply only Brass Valve for CO2 Fire extinguisher of any capacity
15Supply only Bend Horn for CO2 Fire extinguisher of any capacity
16Supply only Brass Cap for Water & Mechanical foam Fire extinguisher of any capacity
17M&L for two Coats of Anti corrossive paints red colour of adequated Micron rating on galvanized surfaces including repartion of surfaces including cleaning after rust inhibited through a rocess of de-greasing, acid packing, phosp[hating and over a coat of red oxide primer after painting necessary stickering suitable for fire extinguisher typer and capacity including transportation from DIPAC to contractor"s workshop and back complete all as specified and as directed by Engineer-in-Charge for the following items:- Make:- Asian Paints/Berger/Acco Paints/ Dulux
18M&L for two Coats of Anti corrossive paints red colour of adequated Micron rating on galvanized surfaces including repartion of surfaces including cleaning after rust inhibited through a rocess of de-greasing, acid packing, phosp[hating and over a coat of
19Fire beater
20Fire Hook
21Fire Bucket
22Fire Shovel
23Supply of new fire buckets in replacement of old rusted fire buckets of capacity 10 Ltrs including two Coats of Anti corrossive paints red colour including preparation of surfaces over a coat of red oxide primer after painting necessary stickering as directed complete all as specified and as directed .
24Supply of new Fire beater in replacement of old rusted fire beater including two Coats of Anti corrossive paints red colour including preparation of surfaces over a coat of red oxide primer after painting necessary stickering as directed complete all as specified and as directed .
25Supply of new Fire hook in replacement of old rusted fire hooks including two Coats of Anti corrossive paints red colour including preparation of surfaces over a coat of red oxide primer after painting necessary stickering as directed complete all as specified and as directed.
26Supply of new Fire Shovel in replacement of old rusted fire shovel including two Coats of Anti corrossive paints red colour including preparation of surfaces over a coat of red oxide primer after painting necessary stickering as directed complete all as specified and as directed .
27Supplyingand fixing in repair of Fire Extinguisher Carbon dioxide (CO2) extinguishers consisting of welded M.S. cylindrical body, light weightsqueeze lever discharge valve fitted with pressure indicating gauge with internal discharge tube, discharge nozzle suspension bracketof capacity 4.5 Kg as per IS: 2878 complete with holding accessories including taking down old unserviceable one complete all as specified & directed. Make:- Minimax/ Firex/ Newage/ Nitin/ Cease Fire
28ditto-all as per item No. 12.00 above butCO2 of capacity 6 Kg. Make:- Minimax/ Firex/ Newage/ Nitin/ Cease Fire
29Comprehensive maintenance of Gas based fire suppression system comprising 2X60 Kgs seamless cylinder with valves and all connected electromagnetic actuators and kit complete including MS seamless pipes as ASTMA 106-250 etc in old server room Automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and then be capable of operating the system for 2 hours during an emergency conditions as required. etc.and all as directed. The system comprising of following items as specified & directed . (a) Gas suppression system control panel (make Agni) - 01 No. (b) Gas Cylinder 60 Kg capacity - 02 Nos. (c) Solenoid valve - 02 Nos. (d) Smoke detectors - 12 Nos. (e) Gas Nozzle - 06 Nos. (f) Hooter - 01 No. (g) Gas abort push button - 01 No. (h) Gas release push button - 01 No. (j) SMF Battery 7AH - 02 Nos. (k) Steel hose pipe - 1 Lot. (l) Control wiring complete.
30Comprehensive maintenance of Gas based fire suppression system SINOREX 1230 system comprising 2 X 90 Kgs seamless cylinder with valves and all connected electromagnetic actuators and kit complete including MS seamless pipes as ASTMA 106-250 etc in New server room Automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and then be capable of operating the system for 2 hours during an emergency conditions as required. etc. and all as directed. The system comprising of following items as specified & directed. (a) Gas suppression system control panel (make Ravel RE120GR) - 01 No. (b) Gas cylinder 90 kg capacity - 02 Nos. (c) Solenoid valve - 01 No. (d) Gas Nozzle - 03 Nos. (e) Hooter - 01 No. (f) Gas abort push button - 01 No. (g) Gas release push button - 01 No. (h) SMF Battery 26 AH - 02 Nos. (j) Steel hose pipe - 01 Lot. (k) Control wiring complete.
31Comprehensive maintenance of microprocessor based net workable analogue adderssable type 1-2 fire alarm control panel expandable to 10 loops each loop are connected 252 analog addressable devices in one loop each loop are loaded to 90% of its full capacity including comprising hooter cum stoable red colour with 99 db sound output vesda detector for new server room. Automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and then be capable of operating the system for 2 hours during an emergency conditions as required. etc. For New server room. The system comprising of following items as specified & directed. (a) Fire alarm system control panel (make Notifier) 01 No. (b) Smoke detectors - 18 Nos. (c) Response indicator - 13 Nos. (d) Hooter - 01 No. (e) Manual call point - 01 No. (f) VESDA panel - 01 No. (g) SMF Battery 26 AH - 02 Nos. (h) Air aspirator - 01 Lot. (i) Control wiring complete.
32NOTE FOR ITEM NOS. 14 to 16 :- (a) Working Hrs: Monday to friday .Timings: 0900 Hrs to 1700 Hrs for monthly preventive maintenance. (b) If there is any complaint at day/night (including sunday & holidays) contractor / Auth rep of contractor /supervisor should rectify the same within fourhours,failingwhich a penalty @ Rs.3000/-per day shall be imposed upon the contractor. (c) Weekly preventive maintenance will be carried out by qualified thechnician should least ITI holder and approved by Engr-in-charge and with minimum three years experience in the same field. (d) Monthly inspection & testing report shall be maintained. report shall be signedby MES representative & user weekly. (e) Items required for replacement /repairs shall be supplied by the contractor & costof minor items such as nuts,bolts screws including replacement of spare parts of control panel ICs/rectifiers/LED etc and internal wiring of control panel are deemed to be included in the quoted rate. (f) Except filling of gasNAFS-125. (Gas filling by the department after refilling of cyclinder all electrical/solinied valve connections including of testing and commissioning deemed to be included in abovequoted rates.
33Supply and fixing of intelligent addressable photoelectric type optical smoke detector including taking down old unserviceable one complete all as specified and as directed along with comprising the following:- Operating Voltage: 15-27 V DC Current: 200µA Alarm Current : 1mA Smoke sensitivity : 0.5-3.5& obscuration/ foot Operating temperature : 0o C – 49o C Humidity : 0-95% RH (Non condensing) Colour : White Housing : Polycarbonate Contact clamps : Stainless Steel Indications Normal : Green LED (Blinks during scan) Alarm : Red LES (Glow steady) (Make: Edward EST Model No SIGA2-PS or equivalent of SYSTEM SENSOR/ APPOLO/ HONEYWELL / NOTIFIER)
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail