Tender For Construction Of Auditorium Cum Administrative Block At Islamia College Srinagar, srinagar-Jammu And Kashmir

Public Works Department-PWD has published Tender For Construction Of Auditorium Cum Administrative Block At Islamia College Srinagar. Submission Date for this Tender is 20-10-2023. Auditorium Construction Tenders in srinagar Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

40026436
Tender For Construction Of Auditorium Cum Administrative Block At Islamia College Srinagar
Open Tender
Indian
Jammu And Kashmir
srinagar
20-10-2023

Tender Details

Construction Of Auditorium Cum Administrative Block At Islamia College Srinagar

Key Value

Document Fees
INR 8500 /-
EMD
INR 1460720.0 /-
Tender Value
INR 7.30 Crore /-

BOQ Items

Name of Work: Construction of Administrative cum Auditorium Block at Islamia College Hawal Srinagar Advertised Cost: Rs. 730.36 Lacs
Sl. No. Item Description
1Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge.All kinds of soil
2Extra for every additional lift of 1.5 m or part thereof in excavation/banking excavated or stacked material All kinds of soil
3P/L stone soling(Hand packed) in trenches incl. ramming, dressing ,watering etc.incl. all leads, lifts and carriage upto site of work complete.
4Providing and laying in position cement concrete of specified grade excluding the cost of centering and shutttering. All work upto plinth level 1:4:8 (1 cement:4coarse sand:8 graded stone aggregate 40mm nominal size (crushed) incl. cost and carriage ofall materials involved complete.
5Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. (Back filling)
6Supplying and filling RBM under rooms incl. compaction by ramming watering etc all carriages complete job
7Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable separately.All works upto plinth levelincl. cost and carriage ofall materials involved complete.
8Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable separately.All works upto floor V levelincl. cost and carriage ofall materials involved complete.
9Extra for providing richer mixes at all floor levels. Note:- Excess/ less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC.
10Add or deduct for using more or less cement in the items of design mix over and above the specified cement content therein
11Providing and laying in position cement concrete of specified grade excluding the cost of centering and shutttering. All work at all levels1:2:4 (1 cement:2coarse sand:4 graded stone aggregate 20mm nominal size (crushed) incl. cost and carriage ofall materials involved complete.
12Centering and shuttering including strutting, propping etc. and removal of form for :
13Foundations: footings, bases of columns etc. for mass concrete.
14Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc
15Suspended floors, roofs, landings, balconies and access platform.
16Lintels, beams, plinth beams, girders, bressumers and cantilevers.
17Columns, pillars, piers, abutments, posts, and struts.
18Stairs (excluding landings) except spiral staircases.
19Edges of slabs and breaks in floors and walls Under 20 cm wide
20Reinforcement for RCC work incl. straightening cutting, bending, placing in position and binding all complete (TMT) incl. cost cost and carriage of all materials involved complete.
21Brick work with F.P.S. bricks of class designation 75 in superstructure upto floor V level in Cement mortar 1:6 (1 cement: 6 coarse sand)including cost and carriage of all materials involved upto site of work complete.
22Half brick masonary with F.P.S bricks of class designation 75 in superstructure upto floor V level in cement mortar 1 :4 (1 Cement : 4 coarse sand ) incld cost and carriage of all materials involved upto site of work complete.
23Providing wood work in frames of doors,windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately). First class kail wood
24Providing 40x5mm flat iron hold fasts 400mm long incl. fixing with frames with 10mm dia bolts, nuts wooden plugs and embedded in c. conc. Block 30x10x15cm in 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
25Providing and fixing 35mm ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.With ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws
26Providing and fixing 35mm thick glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.First class kail wood.
27Providing and fixing 35mm thick wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge .First class kail wood
28Providing and fixing 3.5 thick glass panes incld cost of beading etc complete as per directions of Engineer Incharge at site complete.
29Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 250x16 mm
30Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete
31200 x10mm
32100 x10mm
33Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete.
34150mm
35100mm
36Providing and fixing aluminum hanging floor door stopper, ISI marked, anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : Single rubber stopper
37Providing and fixing PVC rigid foam sheet 1mm thick on existing door shutters (bathroom and W.C. doors) using synthetic rubber based adhesive and other allied fixing material to fix it properly on base complete job
38Providing and laying Anti skid vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete (Size 300 x 300mm)
39Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with with water proofing cement compound @ 0.253kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm . This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.The rate includes reparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
40Providing and laying Anti skid vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete (Size 600 x 600mm)
41Tile work in skirting, risers of steps and dado (upto 2 m height) over 12 mm thick bed of cement mortar 1:3 (1 cement:3 coarse sand) and jointed with grey cement slurry @ 3.3 kg/sqm including pointing in white cement mixed with pigment of matching shade complete. 8 mm thick
42Providing and laying Vitrified floor tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement and matching pigments etc. complete. 450mm x 300mm
43Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand: 4crushed stone aggregate) with a floating coat of neat cement slurry , but excluding cost of nosing of steps etc. complete 50mm thick with 20mm nominal size crushed stone aggregate incl. cost and carriage of all materials involved complete.
44Providing and laying 18mm thick gang saw cut of specified thickness, mirror polished pre- moulded and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring in road side plazas and similar locations, laid over 20mm thick base of cement mortar 1:4 (1cement : 4 coarse sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch ups etc. complete as per direction of Engineer-in-Charge.
45Providing edge moulding to 18 mm marble stone /granite stone counters, Vanities etc.including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge (Granite Work) Double moulding
46Providing and fixing M S railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishing and making curvature (wherever required) and P/F 75mm x 100mm ornamental top rail made of Ist class imported wood incl fitting the same with necessary steel nuts and bolts complete ,including fixing the railing with necessary accessories and stainless steel dash fasteners, steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge,
4712mm cement plaster on the rough side of single or half brick wall of mix 1:6 (1 cement : 6 fine sand)(including cost of all material, leads, lifts and carriages etc upto site of work complete).
4815mm cement plaster on the rough side of single or half brick wall of mix 1:4(1 cement:4 fine sand)(including cost of all material, leads, lifts and carriages etc upto site of work complete).
49Providing and applying 2mm thick white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
50Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content with water thinnable cement primer on wall surface having VOC content less than 50 grams/liter
51Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/ liter of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. (Two Coats)
52Finishing walls with textured exterior paint of required shade on New work (two or more coats applied @ 3.28 liter/10sqm) over and including base coat of exterior primer applied @ 2.20kg/10sqm
53Applying priming coat with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood).
54Painting with synthetic enamel paint of approved brand and manufacture of required color to give an even shade. Two or more coats on new work.
55Structural steel work welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position including welding etcand applying a priming coat of approved steel primer all complete.
56Providing and fixing mild steel round holding down bolts with nuts and washer plates complete.
57Providing & fixingcolourcoated galvalume high ribprofile sheets 0.50 mm TCT having a crest height of 28-32mm at 195mm pitch and effective width of 975-1000mm and length to suit site requirement to the purlins using self drilling and selftapping fasteners of reputed make withpurlin sheet using self drilling and self tapping fastners & Fixingflashings, valleys and ridges of colour coated galvalume plain sheetusing self drilling and selftapping fasteners of reputed makel complete and as directed.The contractor shall give a minimum of 10 years guarantee for sheets against deterioration, disintegrations loss of luster, variation in colour, etc. and leakages across laps, fasteners etc. All types of steel sheets shall be load tested to satisfy 1.10 times the design wind load and coating thickness to the satisfaction of the Engineer-in-Charge. Fasterners shall also be load tested. The Contractor is to submit design and shop drawings for approval on the sheet profile, design and fabrication details before installation(including cost of all material, leads, lifts and carriages etc upto site of work complete).
58Providing and fixing precoated galvanised steel sheet roofing accessories0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm)
59Providing valleys of 90cm wide overall in plains G.S. sheets fixed with polymer coated J. or L. hooks, bolts and nuts 8 mm dia G I. limpet and bitumen washers complete.1.25mm thick with zinc coating not less than 350gm/m2
60Providing and fixing plained eaves boarding. Ist class imported wood 300x40 mm (nominal size) complete job
61Providing and fixing of soffits made out of M.S sheet angle iron of requires size and guage including cutting welding and fixing in position including applying a priming coat of approved steel primer and two or more coats of steel paint and scaffolding carriage complete
62Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS:277 and consisting of angle cleats of size 25 mm widex1.6mm thick with flanges of 27mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mmdiax40mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.5mm of required length with nuts & bolts of required size and other end of angle hanger fixed with G.I. channels 45x15x0.9 mm running at the spacing of 1200 centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having clips of 10.5 mm at 450mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64mm diaX230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre to centre, with 25mm long drive-all screws @ 230 mm interval ,including fixing of gypsum board/calcium silicate board to ceiling section and perimetre channel with the help of dry wall screws of size 3.5x25mm at 230mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the gypsum board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers’ specification and also including the cost of making openings for light fittings, grills diffusers, cutouts made with frame of perimetre channels suitably fixed all complete as per drawing and specification and direction of the Engineer-in-Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095-Part 1 : 2011 (Board with BIS certification marks)
63Plumbing Work
64Providing and fixing Floor mounted white vitrous china double trap syphonic WC with 10 litre cistern and all fittings & fixtures,seat cover etc with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :
65Providing and fixing of water closet squatting pan indian type W.CPan with 100 mm sand cast iron p or strap 10 litre low level P.V.C flushingCistern including flushing pipe of approved make complete job.(a) Orissa pattern white vitreous china W.C pan of size 580x440 mm.
66Providing and Fixing 2 Nos. support arms and backrest to mounted on the track (vertically and laterally)for handicap toilet complete as required.
67Providing and fixing viterous china / wash basin with pedestal of approved quality completely recessed at the back for the reception of pipes and fittings of size. 550mmx400mm.
68Providing and fixing in position Indian make (Ordinary) Lavatory suits Conisting of Lavatory in Vitreous China ware size as given Below (to the approval of the Engineer-in-charge)including china plug for tap hole where necessary; R.S or C.I Brackets for building into wall including Painting; 32 mm C.P Brass Waster with C.P brass chain and rubber plug; 15 mm C.P Brass Elbow operated Tap.Size 530 mm x 430 mm with Elbow operatedtrap.(For Lavatory.) White
69Providing and fixing viterous china / wash basin with pedestal of approved quality completely recessed at the back for the reception of pipes and fittings of size. 630mmx450mm.
70Providing and Fixing stainless steel kitchen sink incl. c/o C.P waste, PVC waste pipe & making all connection complete of app. Make610 x 510 x200mm)
71Providing and fixing C.P Brass 32mm size bottle trap of approved quality & make and as per the direction ofengineer-in-charge
7232mm dia
7340mm dia
74Providing Sink mixer (wall mounted) with 170mm long swivel spout connecting legs and wall flanges((CERA Cat. No. OCEAN F3002501 or approved equivalent) .
75Providing and fixing Braided Hoses with Two 15mm CP Brass Nuts & Rubber Washers Without Nipple (Suitable for Geysers and basins) of approved make : 15mm nominal bore
7645 cm length
77Providing and fixing CP brass toilet paper holder
78Providing,Fixing,testing and commissioning of CP brass twin coat hook with concealed screws.
79Providing and Fixing Health Faucet 15mmdia with CP flush pipe, CP nozzel hook complete including CP flange etc.
80Providing,Fixing,testing and commissioning of CP brass towel ring hook with concealed screws.
81Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 .15 mm nominal bore
82Providing and fixing PTMT soap dish holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106gms.
83Providing and fixing horzontal/vertical Hot water geyser made of MS body with copper jacket inside with necessary inlet, outlet, drain, overflow, vent and all safety accessories etc. complete including cutting and making good the walls, wherever required.
8415 lit for Kitchen(For small toi. And pantry.)
8525 lit for Toilet
86Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
87Providing and fixing C.P. brass/ SS long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.15 mm nominal bore (for wc Areas.)
88Providing and fixing C.P. brass/ SS stop cock (concealed) of standard design and of approved make conforming to IS:8931.15 mm nominal bore(for drinking area)
89Providing & Fixing water purifier cum water cooler made of stainless steel having storage capacityof 80 litre/hourwith reverse osmosissystem and ultra voilet membrane TDSreduction 905 having automatic back wash system with filteration unit & all other required accessories complete in all respect as per direction of the of the engineer incharge
90Providing and fixingof fully automatic "NO TOUCH" ABS Bodyhand drier suitable to operate on 220 volts, single phase 50 hz, A.C. power supply and directly plugged to power point complete
91Soil, Waste, Vent Rain water pipes
92Providing and fixing UV stabilised UPVC pipes, Type B as per IS:13592 for soil, waste, rain water and vent, including all fittings with or without access i.e Clean out plug,bends, junctions, cowls, offsets, couplers, connectors, heavy duty Metal pipe clamps with rubber seal/clips//holders etc. and jointing with heavy duty solvent cement, complete as per manufacturer"s specificationsand making good the same, complete as directed by the Engineer-in-Charge. (vertical pipes can be jointed through rubber O rings) Inclouding cement concrete 1:2:4mix (1 cement :2 coarse sand :4 graded stone aggregate, 20 mm down gauge) 75 mm in bed and all around soil and waste pipes under floor, including shuttering and centering for:
9375mmouter dia.
94110mmouter dia.
95160mmouter dia.
96Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. :100mm dia pipe
97Providing and fixing multi inlet uPVC floor trap with minimum 50mmwater seal of self cleaning design with 110 mm outlet consisting of all necessary fittings and provding strainer of 150 x 150 mm square stainless steel 2 mm thk frame with slotted lockable grating on top of the trap level matching the level of floor finish etc, complete including cost of cutting and making good the walls and floors wherever required and as directed by Engineer in charge. (The inlet diameter shall be 32mm, 40mm or 50mm as per site requirements)
98Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof.
99Providing and fixing uPVC pipe as per IS 4985, Class-3, 6Kg/cm2 with cement solvent joint, complete with all fittings and clamps etc including cutting and making good the walls and floors for waste pipes from wash basins, urinals, sinks & balcony drainage, as directed by the Engineer-in-charge.
10040 mm OD
10150 mm OD
10263 mm OD
103Providing and fixing Upvc inlet Fittings with two or three inlets fittings to receive waste pipes from fixtures waste.
104Providing and fixing SS grating with frame including fixing to the floor with cement mortar.
105100mm dia
106Providing and fixing 110mmx50mm outlet. UPVC floor drain consisting of all necessary fittings and provding strainer of 150 x 150 mm square stainless steel 2 mm thk frame with slotted lockable grating on top of the trap level matching the level of floor finish etcall complete as per specifications and direction of Engineer-In-Charge.
107Providing and fixing GI. inlet hopper of C class pipe with two or three inlets fittings, connection with saddle, to receive waste pipes from fixtures waste.
108Providing and fixing SS grating with frame including fixing to the floor with cement mortar.
109125mm x 125mm
110Providing & fixing ofcast brass clean out plug(floor/ceilling) with suitable insert keys for opening in: brass cap, male threaded joint with threaded G.I socket fixed to HCI soil pipe or C.I.(LA) pipe joints as required complete in all respects.
111110mmouter dia.
112160mmouter dia.
113Providing and fixing floor drain points formed out of 100 X 50mm dia reducing elbow embedded in floor,all completein all respect as directed.
114PP-R should be a complete installation system consisting of pipes and fittings of a thermoplastic polopropylene PP-R 3-layer glass fibre compound (type 3/ type 4) of PN20 (SDR 6)/PN16 (SDR 7.4) and PP-RCT (SDR9 and SDR11) within a range of diameters 20-200 mm in Green/Grey colour of pipe dimension series in accordance with EN ISO 4065 having linear expansion of 0.05 mm/mK with DVGW and QB/CSTB certification as per EN ISO 15874-2:2013-06E, EN ISO 15874-3:2013-06E standard. System elements are connected by muff-welding (thermal polyfusion) or electrofusions welding with the use of electric welders. The welding technology i.e. uniform connections, guarantees an exceptional leak-tightness and mechanical strenth of a system and use for internal and external water supply, cooling systems (hot and cold water), production process industrial systems and use in shafts, basements, terrace with insulation. : MAKE : KAN-therm, Aquatherm, Poloplast. Concealed work including cutting chases and making good the wall.
11516x2 mmouter dia pipe
11620x2 mm pipe
11725x2.5 mmouter dia pipe
11832x3 mm outer dia pipe
11940x3.5mmouter dia pipe
120PP-R should be a complete installation system consisting of pipes and fittings of a thermoplastic polopropylene PP-R 3-layer glass fibre compound (type 3/ type 4) of PN20 (SDR 6)/PN16 (SDR 7.4) and PP-RCT (SDR9 and SDR11) within a range of diameters 20-200 mm in Green/Grey colour of pipe dimension series in accordance with EN ISO 4065 having linear expansion of 0.05 mm/mK with DVGW and QB/CSTB certification as per EN ISO 15874-2:2013-06E, EN ISO 15874-3:2013-06E standard. System elements are connected by muff-welding (thermal polyfusion) or electrofusions welding with the use of electric welders. The welding technology i.e. uniform connections, guarantees an exceptional leak-tightness and mechanical strenth of a system and use for internal and external water supply, cooling systems (hot and cold water), production process industrial systems and use in shafts, basements, terrace with insulation. : MAKE : KAN-therm, Aquatherm, Poloplast.Exposed on wall/terrace
12116x2 mmouter dia pipe
12220x2 mm outer dia pipe
12325x2.5 mm outer dia pipe
12432x3 mmouter dia pipe
12540x3.5mmouter dia pipe
12650x4mmouter dia pipe
127Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete
12815 mm nominal bore
12920 mm nominal bore
13025 mm nominal bore
13132 mm nominal bore.
13240 mm nominal bore
13350 mm nominal bore
134Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required
13565 mm nominal bore
13680 mm nominal bore
137100 mm nominal bore
138Providing and fixing C.I. dirt box strainer for bulk type water meterwith nuts, bolts, rubber insertions etc. complete conforming to IS :2373:00:00
13980 mm dia
140100 mm dia
141150 mm dia
142Providing and fixing gun metal non- return valve of approved quality (screwed end) :25 mm nominal bore
14325 mm nominal bore
144Horizontal
145Vertical
14632 mm nominal bore
147Horizontal
148Vertical
149Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid separately) :80 mm dia nominal bore
150Disinfecting C.I. water mains by flushing with water containing bleaching powder @ 0.5 gms per litre of water and cleaning the same with fresh water, operation to be repeated three times including getting the sample of water from the disinfected main tested in the municipal laboratory.
15180 mm diameter C.I. pipe
152100 mm diameter C.I. pipe
153Providing and fixing of approved make float operated ball valve with Brass/copper heavy duty float confirming to IS 9762 & other associated accessories & works etc., complete. For 80mm dia pipe
154External Water Supply
155PP-R should be a complete installation system consisting of pipes and fittings of a thermoplastic polopropylene PP-R 3-layer glass fibre compound (type 3/ type 4) of PN20 (SDR 6)/PN16 (SDR 7.4) and PP-RCT (SDR9 and SDR11) within a range of diameters 20-200 mm in Green/Grey colour of pipe dimension series in accordance with EN ISO 4065 having linear expansion of 0.05 mm/mK with DVGW and QB/CSTB certification as per EN ISO 15874-2:2013-06E, EN ISO 15874-3:2013-06E standard. System elements are connected by muff-welding (thermal polyfusion) or electrofusions welding with the use of electric welders. The welding technology i.e. uniform connections, guarantees an exceptional leak-tightness and mechanical strenth of a system and use for internal and external water supply, cooling systems (hot and cold water), production process industrial systems and use in shafts, basements, terrace with insulation. MAKE : KAN-therm, Geberit, Uponor Including all excuvation and refilling etc as required by direction of engineer in charge.External work
15640x5.5 mm outer dia pipe
15750x6.9 mmouter dia pipe
15863x8.6 mmouter dia pipe
159Providing and filling sand of grading zone V or coarser grade, allround the 3 layer PP-R (Poly propylene Random copolymer) pipes in external work :
16040 mm dia
16150 mm dia
16265 mm dia
163Constructing masonry Chamber 60x60x75cm, inside with cementblock work in cement mortar 1:4 (1 cement : 4 fine sand) for sluice valve, with C.I surface box 100mm. top diameter,160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10graded stone aggregate 40mm nominal size) and inside plastering with cement mortat 1:3 ( 1cement :3 coarse sand) 12mm thick finished with a floating coat of neat cement complete as per standard design.CementBlocks, Size (Inches): 24 x 8 x 4
164Constructing masonry Chamber 60x45x50 cm inside, in cementblock work in cement mortar 1:4 (1 cement : 4 coarse sand) for water meter complete with C.I. double flap surface box 400x200x200 mm (inside) with locking arrangement and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :With common CementBlocks, Size (Inches): 24 x 8 x 4
165Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid separately) : 80 mm dia nominal bore
166Effecting connection from Existing/ Municipal Water Supply line including necessary excavation & making goodthesame includingcutting, boring and tapping the Existing line by providing andinstallingferrule / Tee connections with necessary fittings as requiredand makinggoodthesame. The rate for this item also includes completeservices from the contractor for liasoning works such as filingnecessaryapplications, submission offormsforapprovalto the municipal authorities, depositingthe fees /otheramountsas requiredfor gettingthepremises / installations, inspectedand approved and allother formalities requiredtillthe waterconnectionisobtained.Allthe expenses incurred in this regard shall be bornebytheContractorexcept for the official paymentstobemadeforanysecurity depositetc. whichwill be reimbursed on production of original voucher.
167External Sewage and Storm Water
168Excavatingtrenches of requiredwidthforpipes, cablesetc. including excavationfor socketsand dressingof sides,ramming ofbottoms, depth upto 1.5M including gettingoutthe excavated soil, and then returning the soilas required, in layers not exceeding20cms indepth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed,withina leadof 50 m. All kinds of soil.
169Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia. Metre
170Providing and laying cementconcrete 1:5:10 mix (1cement: 5coarsesand:10 graded stone aggregate 40 mmnominal size) upto haunches forpipes including bed concrete as per standard design.
171150 mm dia.
172200 mm dia.
173300 mm dia.
174Providing, laying, jointing and commissioning of PVC pipe As/IS:15328with pussfit joint with solvent including testing of joints etc. complete as directed by Engineer in charge.(inclouding allround cement concrete).
175150 mm dia.
176200 mm dia.
177300 mm dia.
178Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating cementblock masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 180x150 mm size P type. With Sewer cementblock conforming to IS : 4885
179Constructing cementblock masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :Insidesize90x80 cms and 45 cmsdeep including CIcover withframe (Light duty) 610x455mminternal diamesions total weight of cover and frame to be not less than 38 kg ( weight of cover 23 kg and weight of frame 15 kg). With common CementBlocks, Size (Inches): 24 x 8 x 4
180Extra for depth for manholes. Size 90x80 cm .With common CementBlocks, Size (Inches): 24 x 8 x 4
181Constructing cementblock masonry circular type manhole 0.91 m internal dia atbottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarsesand), inside cement plaster 12 mm thick with cement mortar 1:3 (1cement : 3 coarse sand) finished with a floating coat of neat cement,foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stoneaggregate 40 mm nominal size), and making necessary channel incement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 20 mm nominal size) finished with a floating coat of neatcement, all complete as per standard design :20.9.10.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20grade designation) 560 mm internal diameter conforming to I.S. 12592,total weight of cover and frame to be not less than 182 kg., fixed incement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 20 mm nominal size) including centering, shuttering allcomplete. (Excavation, foot rests and 12mm thick cement plaster at theexternal surface shall be paid for separately) : With common CementBlocks, Size (Inches): 24 x 8 x 4
182Constructing cementblock masonry circular manhole 1.22 m internal dia atbottom and 0.56 m dia at top in cement mortar 1:4 (1 cement :4coarsesand) inside cement plaster 12 mm thick with cement mortar 1:3 (1cement : 3 coarse sand) finished with a floating coat of neat cementfoundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 40 mm nominal size) and making necessary channel in cementconcrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, allcomplete as per standard design :19.9A.1 1.68 m deep with SFRC Cover and frame (heavy duty HD- 20grade designation) 560 mm internal diameter conforming to I.S. 12592,total weight of cover and frame to be not less than 182 kg. fixed incement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 20 mm nominal size) including centering, shuttering allcomplete. (Excavation, foot rests and 12 mm thick cement plaster at theexternal surface shall be paid for separately) : With common CementBlocks, Size (Inches): 24 x 8 x 4
183Constructing cementblock masonry circular manhole 1.52 m internal dia atbottom and 0.56 m dia at top in cement mortar 1:4 (1 cement : 4 coarsesand) inside cement plaster 12 mm thick with cement mortar 1:3 (1cement : 3 coarse sand) finished with a floating coat of neat cement,foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 40 mm nominal size) and making necessary channel in cementconcrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, allcomplete as per standard design :19.9B.1 2.30 m deep with SFRC Cover and frame (heavy duty HD- 20grade designation) 560 mm internal diameter conforming to I.S. 12592,total weight of cover and frame to be not less than 182 kg. fixed incement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 20 mm nominal size) including centering, shuttering allcomplete. (Excavation, foot rests and 12 mm thick cement plaster at theexternal surface shall be paid for separately) : With common CementBlocks, Size (Inches): 24 x 8 x 4
184Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated asper IS: 10910 on 12mm dia steel bar conforming to IS :1786 having minimun cross section as 23 mm x 25 mm and over all minimum length263mmand width as 165mmwith minimum 112mm space between protruded legs having 2mm tread on top surface by ribbing or chequering besidesnecessary and adequateanchoringprojections on tail length on 138mm as per standarddrawing and suitable to with standthe bend test and chemicalresistance test as per specifications and heaving manufacture"s permanent identification mark to be visible even afterfixing " incluting fixingin manholes with 30x20x15 cm cement concrete block 1:3:6: (1 cement :3 coarse sand :6 gradedstone aggregate 20mm nominal size )complete as per design.
185Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etccomplete.For pipes 250 to 300 mm diameter
186Constructing cementblock masonry road gully chamber 50x45x60 cm with cementblockin cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : With common CementBlocks, Size (Inches): 24 x 8 x 4
187Constructing cementblock masonry road gully chamber 110x50x77.5 cm with cementblocks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm precast R.C.C. horizontal grating with frame and vertical grating complete as per standard design : With common CementBlocks, Size (Inches): 24 x 8 x 4
188Providing and fixing water storage tanks with PVC lid having locking arrangement (triple layer of approved quality sintex or equivalent) incl making inlet outlet and overflow connections
189Electrical Work
190Point Wiring
191Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
192Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
193Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
1942 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire(in minimum 20mm)
1952 X 4 sq. mm +1 X 4 sq. mm earth wire(in minimum 20mm)
1962 X 6 sq. mm +1 X 6 sq. mm earth wire(in minimum 25mm)
1972 X 10 sq. mm + 1 X 6 sq. mm earth wire(in minimum 25mm)
1984 X 1.5 sq. mm + 2 X 1.5 sq. mm earth wire(in minimum 25mm)
1994 X 4 sq. mm + 2 X 4 sq. mm earth wire(in minimum 32mm)
2004 X 6 sq. mm + 2 X 6 sq. mm earth wire(in minimum 32mm)
2014 X 10 sq. mm + 2 X 6 sq. mm earth wire(in minimum 40mm)
2024 X 16 sq. mm + 2 X 6 sq. mm earth wire(in minimum 40mm)
203Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
2043 x 1.5 sq. mm
2053 x 2.5 sq. mm
2063 x 4 sq. mm
2073 x 6 sq. mm
2081 x 10sq. mm
2091 x 16 sq. mm
210Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
21120 mm
21225 mm
21332 mm
21440 mm
215Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.
216100 mm X 100 mm X 60 mm deep
217150 mm X 150 mm X 60 mm deep
218200 mm X 250 mm X 60 mm deep
219250 mm X 300 mm X 60 mm deep
220Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
221Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
222Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlet and 2 Nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
223Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
224Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
225Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required.
226DISTRIBUTION BOARDS
227Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
2288 way, Double door
229Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator)
2306 way (4 + 18), Double door
2318 way (4 + 24), Double door
232Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 160 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCCBs and incomer) as required. (Note : Vertical type MCCB TPDB is normally used where 3 phase outlets are required.) 12 way (MCCB + 36), Double door
233Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
234Single pole
235Triple pole
236Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
237Supplying and fixing following rating, double pole, 240 V, MCB(10kA) in the existing MCB DB complete with connections, testing and commissioning etc. as required.
23840A
239Supplying and fixing following rating, four pole, 415 V, MCB(10kA) in the existing MCB DB complete with connections, testing and commissioning etc. as required.
24040A
24163A
242Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
24340A
24463A
245Supplying and fixing Cable End Box (Loose wire box)(IP 43) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with testing and commissioning etc. as required.For 8 way, Double door SPN MCBDB
246Supplying and fixing Cable End Box (Loose wire box)(IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.
247For 6 way, Double door TPN MCBDB
248For 8 way, Double door TPN MCBDB
249Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
250Supplying and fixing 20 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
251Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A, “C” curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
252Design, fabrication, assembling, wiring, supply, installation, testing & commissioning of (IP:30, IK 08) minimum 1.2mm thick sheet steel DP/TP/FP MCB/ Isolator enclosure conforming to IS: 8623-1 & 3 & IEC 61439- 1&3, made out of pre-treated and powder coated (minimum 60-80 micron), 240/415 V, mount on surface / recess, complete with din bar including earthing stud etc. as standard or as suggested by Architect/Consultant. (But without MCB/RCCB/Isolator).
253Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.100 A, 30kA, FPMCCB
254SUPPLY OF LIGHT FIXTURES AND FANS
255Supply of Recess Mounted Round Led Downlighter consuming a system wattage of 10-12W (±10%)& the luminaire shall be with system efficacy = 100 lm / W. Housing: Die Cast Aluminium. IP20 , Optics:PMMA/Polysterene Diffuser. The operating CCT shall be 5700K with CRI of =80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , THD = 10% & PF = 0.95, 50,000 Hrs LED Life with L70 Criteria. The LED Driver shall be easily avaiable in India for repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2KV.The luminaire shall be with following certifications: LM79& LM80 issued by LED manufacturer along with Photo Biological Safety Standard.
256Supply of indoor type Surface mounted downlighter white CRCA powder coated LED light fixture with total system wattage 10-12W covered by PMMA acrylic diffuser, die cast aluminium housing, high efficiency reflector, prewired electronic driver complete with all accessories suitable for operation on single phase 240V 50Hz AC supply as required. LED shall be SMD type, fixture should have minimum efficacy >=100 lm/W and minimum system lumens 1000.Similar to Bajaj- or equivalent as per approved list of make.
257Supply of indoor type Surface mounted downlighter white CRCA powder coated LED light fixture with total system wattage 18-20W covered by PMMA acrylic diffuser, die cast aluminium housing, high efficiency reflector, prewired electronic driver complete with all accessories suitable for operation on single phase 240V 50Hz AC supply as required. LED shall be SMD type, fixture should have minimum efficacy >=100 lm/W and minimum system lumens 1500.Similar toor equivalent as per approved list of make.
258Supply of 4ftLinear LED luminaire delivering an initial system lumen of 2000 lumens & the luminaire shall be with system efficacy = 100 lm / W. The luminaire Housing shall be made of CRCA & the diffuser shall be of polycarbonate/PMMA. The operating CCT shall be 5700K with CRI of =80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , THD = 10% & PF = 0.95 , 50,000 Hrs LED Life with L70 Criteria, IP20. The LED Driver shall be easily avaiable in India for repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2KV.The luminaire shall be with following certifications: LM79& LM80 issued by LED manufacture along with Photo Biological Safety Standard.
259Supply of 4ftLinear LED luminaire delivering an initial system lumen of 3300 lumens & the luminaire shall be with system efficacy = 100 lm / W. The luminaire Housing shall be made of CRCA & the diffuser shall be of polycarbonate/PMMA. The operating CCT shall be 5700K with CRI of =80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , THD = 10% & PF = 0.95 , 50,000 Hrs LED Life with L70 Criteria, IP20. The LED Driver shall be easily avaiable in India for repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2KV.The luminaire shall be with following certifications: LM79& LM80 issued by LED manufacture along with Photo Biological Safety Standard.
260Supply of 2ftLinear LED luminaire delivering an initial system lumen of 903 lumens & the luminaire shall be with system efficacy = 90 lm / W. The luminaire Housing shall be made of PC & the diffuser shall be of polycarbonate/PMMA. The operating CCT shall be 6500K with CRI of =80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , THD = 20% & PF = 0.95 , 50,000 Hrs LED Life with L70 Criteria, IP20. The LED Driver shall be easily avaiable in India for repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2KV.The luminaire shall be with following certifications: LM79& LM80 issued by LED manufacture along with Photo Biological Safety Standard. (Similar to Wipro Cat No.: LL20-111-XXX-65-NE or equivalent as per approved list of make)
261Supply of Recess mounted LED 2"x2" luminaire delivering an initial system lumen of 3300 lumens & the luminaire shall be with system efficacy = 100 lm / W. Housing: CRCA, Rim: Engneering plastic / CRCA. Optics: polycarbonate/PMMA/Polysterene, IP20 Protection. The operating CCT shall be 5700K with CRI of =80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , THD = 10% & PF = 0.95, 50,000 Hrs LED Life with L70 Criteria. The LED Driver shall be easily avaiable in India for repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2KV.The luminaire shall be with following certifications: LM79& LM80 issued by LED manufacture along with Photo Biological Safety Standard.
262Supply, installation, testing & commissioning of Recessed Round adjustable Led Downlighter consuming a system wattage of 14-16W (±10%)delivering an initial system lumen of 1400 lumens & the luminaire shall be with system efficacy = 100 lm / W. Housing: Powder coated Die Cast Aluminium. IP20 , Optics: Reflector with Glass . The operating CCT shall be 4000K with CRI =80. The luminaire shall be with BIS Registered DALI dimmable electronic driver with input voltage range of 150 to 270V , THD = 20% & PF = 0.95, 50,000 Hrs LED Life with L70 Criteria. The LED Driver shall be easily avaiable in India for repair and service. The LED shall be COB type. Luminaire shall have minimum surge protection of 2KV.The luminaire shall be with following certifications: LM79& LM80 issued by LED manufacturer along with Photo Biological Safety Standard.
263Supply, installation, testing & commissioning of Recessed Round adjustable Led Downlighter consuming a system wattage of 41W (±10%)delivering an initial system lumen of 4100 lumens & the luminaire shall be with system efficacy = 100 lm / W. Housing: Powder coated Die Cast Aluminium. IP20 , Optics: Reflector with Glass . The operating CCT shall be 4000K with CRI =80. The luminaire shall be with BIS Registered DALI dimmable electronic driver with input voltage range of 150 to 270V , THD = 20% & PF = 0.95, 50,000 Hrs LED Life with L70 Criteria. The LED Driver shall be easily avaiable in India for repair and service. The LED shall be COB type. Luminaire shall have minimum surge protection of 2KV.The luminaire shall be with following certifications: LM79& LM80 issued by LED manufacturer along with Photo Biological Safety Standard.
264Supply of 3W LED 2 Module Step/Skirting Light with Back box.
265Supply of LED street light with high pressure die cast Aluminium/ standard alloy/ CRCA housing with Polycarbonate diffuser with integral constant current driver input operating voltage range 150V – 270V 50Hz AC supply, prewired upto the terminal block. System lumen output = 4500 lumens with luminaire efficacy = 100lm/W, lumen maintainence of 70% at the end of 50000 burning hours, CCT of 5700K - 6500K, PF=0.95, CRI=70, THD<10%, surge proctection of = 10kv and IP=65 protected with separateoptics and control gear compartment, toughened glass protector, permanently sealedand a removable control gear plate, , mounting spigot suitable for horizontal mounting (Ø 32 – 42mm) with tilt flexibility of (+)(-) 10 degrees. LM 79 report to be submitted for luminaire from NABL accrediated lab and LM 80 for LED source issued by LED manufacture. LED shall have reverse polarity, open and short circuit protection.
266Supplying of Solar street light with IP 65 LED fixture having a system wattage of 40W with 4000 lumen system output, 160Wp high efficiency Poly crystalline solar panel certified IEC 61215 and 100Ah tubular VRLA gel battery with BIS approval. LED system lumen efficacy shall be at least 100 lumens / watt and the LED driver should have > 90% efficiency operating on 12V DC.The battery shall not be discharged beyond 75% of capacity. The solar charge controller should be of Microprocessor Based MPPT make with 94% efficiency and enclosed in IP 65 box. The charge controller shall provide all safety protections and temperature compensated charging of the battery. The battery should be housed in a box made from galvanized steel and epoxy polyester powder coated so that it withstands corrosion.The solar system should be mounted on a 7.0m height Octagonal galvanized pole of 4mm thickness which shall be secured with foundation bolts and nuts.
267Supply of LED Bollard having lumen not lessthan 855 lumenswithluminaire efficacy of not less than 95 lumens per watt, lumen maintainence of 70% at the end of 50000 burning hours with constant current driver output, Power Factor =0.95 & THD <10%, CRI>70,neutral white light and made of GI pipe bottom housing the control gear speen Aluminium dome shaped type cover with cylindrical dome shaped top cover, overall lenght of bollard to be minium of 600 mm, operating range 150V – 270V, 50Hz AC supply, inbuilt driver with surge protection =10KV. The luminaire shall be minimum IP:65 protected. LM 79 report to be submitted for luminaire from NABL accrediated lab and LM 80 for LED source issued by LED manufacture. LED shall have reverse polarity, open and short circuit protection.
268Supply of LED Post Top Light with high pressure die cast Aluminium/ standard alloy/ CRCA housing with Polycarbonate diffuser with integral constant current driver input operating voltage range 150V – 270V 50Hz AC supply, prewired upto the terminal block. System lumen output = 4500 lumens with luminaire efficacy = 100lm/W, lumen maintainence of 70% at the end of 50000 burning hours, CCT of 5700K - 6500K, PF=0.95, CRI=70, THD<10%, surge proctection of = 10kv and IP=65 protected. LM 79 report to be submitted for luminaire from NABL accrediated lab and LM 80 for LED source issued by LED manufacture. LED shall have reverse polarity, open and short circuit protection.
269Supply of 5 star rated 1200mm sweep ceiling fan, ISI marked, along with copper wound stator, blades, capacitor, downrod etc. but without regulator complete as required.
270Supply of 5 star rated 900mm sweep ceiling fan, ISI marked, along with copper wound stator, blades, capacitor, downrod etc. but without regulator complete as required.
271Supplyof 300mm dia sweep PVC body, 900±10% RPM Exhaust fan with guard and mounting arrangement.
272Supply of 450mm dia sweep wall fan Hi speed with 3 speed push buttons, 1440 RPM, with guard and mounting arrangement.
273Supplying of7m MS pole provided with 35-55 micron Anti rust coating & PU (PolyUrethane) Painted, the pole coating includes red oxide and PU synthetic paint coatings in 2 layers. The pole shall be made of 3.0mm thick sheet with 80 mm outer dia with a base plate minimum of 300mm X 300mm, thickness- 15 mm, 2Nos Template and 4 nos ofGI. founadation nut & bolt (25mm dia & 250mm long) complete as required.
274Installation of 7m high M.S. street light pole including including installation of street light fitting (Cost of fitting not to be considered here) with all accessories and supply & making foundation of reinforced cement concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 40mm nominal size) including 2Nos. supply and laying of 50mm PVC pipe from ground to terminal box including excavation and refilling, including positioning of template & foundations bolts (supplied with pole to match with pole base plate) complete as required and as specified.
275Supplying and fixing of MS Single arm 40 mm dia X 1.5 Meter long provided with 35-55 micron Anti rust coating & PU (PolyUrethane) Painted, the arm coating includes red oxide and PU synthetic paint coatings in 2 layers for mounting of LED street light & flood light fitting including bracket with nuts, bolts and washer for mounting on pole top complete as required.
276Supplying and fixing of MS Double arm 40 mm dia X 1.5 Meter long provided with 35-55 micron Anti rust coating & PU (PolyUrethane) Painted, the arm coating includes red oxide and PU synthetic paint coatings in 2 layers for mounting of LED street light & flood light fitting including bracket with nuts, bolts and washer for mounting on pole top complete as required.
277Supply of LED flood light with high pressure die cast Aluminium/ standard alloy and LEDs of approved make fixed on diecast aluminium housing and high efficiency diffuser, Driver installed on cast aluminium housing and prewired upto the terminal block. It has a system lumen output not less than 35000 lumens with luminaire efficacy of not less than 100lm/W and lumen maintainence of 70% at the end of 50000 burning hours with constant current driver output, operating range 150V – 270V, 50Hz AC supply, CCT of 5700K - 6500K with PF=0.95 and THD<10%& surge proctection of =10kv. The luminaire shall be minimum IP:65 protected. LM 79 report to be submitted for luminaire from NABL accrediated lab and LM 80 for LED source issued by LED manufacture. LED shall have reverse polarity, open and short circuit protection.
278The DIGIDIM 474 , 4-Channel Relay Unit is fitted with high inrush specification relays rated at 16 A per channel, which handle short-lived high peak inrush currents during Switch-on of loads. It can be networked through either DALI or SDIM communication to be incorporated into a DIGIDIM or Imagine lighting control system. The unit has an intuitive LED segment display and push buttons for monitoring, manual configuration and control purposes.
279DALI Power supply Unit, with supplu up to 250 mA. DIN rail mounted Unit , with LED indication to indicate the connection to the mians supply. With DALI Short circuit protected, Over temperature protected, and also operates on a universal supply voltage. WIth DALI Connection 0.5 mmsq to 1.5mmsq soli or stranded, Mains upto 4 mmsq soli or up to 2.5 mmsq stranded.External protection 6A MCB Max. Complies of EN 61000-6-3, EN 61547, EN 60950 with IP 30 ratingand Isolation of 3kV.
280Wall Panel Switch(7 Button)
281INSTALLATIONS OF LIGHT FIXTURES AND FANS
282Installation, testing and commissioning of pre-wired, LED fitting of all types and wattages, complete with all accessories etc. directly on ceiling/ wall including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
283Installation, testing and commissioning of IP65 Solar LED street light / LED Street light/Flood fitting with driver on 4 Meter pole, complete with all accessories. including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
284Installation, testing and commissioning of LED Bollard light fitting with drivercomplete with all accessories. including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
285Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
286Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
287Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep
288Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required.
289Supplying and fixing extra down rod of 10 cm length G.I. pipe,15 mm dia, heavy gauge including painting etc. as required. (Note: More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
290ELV SYSTEM
291FIRE DETECTION SYSTEM
292Supply, Installation, Testing & Commissioningof Addressable Multi-criteria Photo-Thermal Detector with sensitivity range of 0.5 to 4.0% obs/ft.The intelligent multi criteria detection device shall include the ability to combine the signal of the thermal sensor with the signal of the photoelectric signal in an effort to react hastily in the event of a fire situation. It shall also include the inherent ability to distinguish between a fire condition and a false alarm condition by examining the characteristics of the thermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena. The detector shall have twin bi-colour LED for 360 deg viewing. Addressing shall be with user friendly rotary decimal switches. UL268, 7th Edition & FM Approved. Approved Makes : Ansul-Tyco / Notifier/ Rux / JCI(IFC) / Nohmi / Gamewell / Honeywell
293Below False Ceiling
294Above False Ceiling
295Supply , Installation , Testing and Commissioning ofRemote Indicator ( RI) High visibility LED, Wide viewing angle for increased visibility, Discreet design for incorporation in to any décor. RI should be of same make as detectors & devices. Approved Makes : Ansul-Tyco / Notifier/ Rux / JCI(IFC) / Nohmi / Gamewell / Honeywell
296MANUAL CALL POINT
297Supply , Installation , Testing and Commissioning of Addressable Manual Call Point (Pull down / Break Glass Type). The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device UL & FM Approved. Approved Makes : Ansul-Tyco / Notifier/ Rux / JCI(IFC) / Nohmi / Gamewell / Honeywell
298Supply, Installation, Testing & Commissioning of Addressable Control Module for Sounders / Strobes / Sounder cum Strobes. The control module shall provide supervised NAC output rated at 24v DC, 2A. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary decimal switches. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance UL & FM Approved. Approved Makes : Ansul-Tyco / Notifier/ Rux / JCI(IFC) / Nohmi / Gamewell / Honeywell
299Hooter cum strobe
300Supply , Installation , Testing and Commissioning of Sounder cum Strobe rated at 80 dBA @ 3m for Audible annunciation and 115cd flashintg at 1 Hz for visual indication. UL & FM Approved. Approved Makes : Ansul-Tyco / Notifier/ Rux / JCI(IFC) / Nohmi / Gamewell / Honeywell
301FIRE ALARM CONTROL PANEL
302Supply , Installation , Testing and Commissioning of Microprocessor based Multi-loop, True Peer-to-Peer Networkable Addressable Fire Alarm Control Panel with minimum 600 characters LCD display, 4000 event plus 1000 alarm log history events, QWERTY keypad for programming. The panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop. Each loop shall have a capacity of minimum 300 analog addressable devices. The panel shall work in degrade mode in case of CPU failure, Products not having this feature may offer Redundant CPU. Four access levels, flash EPROM, 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and 30 mins in alarm condition. The panel shall be complete with2 ways Communication Fire Fighters System capable of supervising all the speaker circuits with adequate zone control and accessories. Failure of Fire Panel CPU shall not result in failure of DVC operation. The Fire Fighters Telephone System shall be capable of having minimum 30 Telephones in conference in multiple FFT Risers. Designed to meet UL864, 10th Edition & FM approved.Approved Makes : Ansul-Tyco / Notifier/ Rux / JCI(IFC) / Nohmi / Gamewell / Honeywell
30301 Loop Approved Makes : Ansul-Tyco / Notifier/ Rux / JCI(IFC) / Nohmi / Gamewell / Honeywell
304REPEATER PANEL
305Supply , Installation , Testing and Commissioning of Network Repeater Panel with minimum 10" Color Touch Screen display with QWERTY Keypad, mapping minimum 2,00,000 points on network. The NRP shall act as an independent node communicating on the peer to peer network and shall not be dependant on the Fire Panel CPU for operation. Failure of Fire Panel CPU shall not result in failure of NRP operation UL & FM Approved. Approved Makes : Ansul-Tyco / Notifier/ Rux / JCI(IFC) / Nohmi / Gamewell / Honeywell
306Supplying and Laying of 2 C X 1.5 Sq mm multi stranded twisted shielded FRLS Copper cable. Approved makes : Polycab/ RR Kabel/ Paramount/ Parasheild