Tender For Electrical And Allied Works For In-House Statutory Testing And Painting Unit And Degassing Unit With Fire Fighting System Works At Sekmai Bottling Plant, imphal-Manipur

Indian Oil Corporation Limited-IOCL has published Tender For Electrical And Allied Works For In-House Statutory Testing And Painting Unit And Degassing Unit With Fire Fighting System Works At Sekmai Bottling Plant. Submission Date for this Tender is 13-10-2023. Fire Fighting Consumable Tenders in imphal Manipur. Bidders can get complete Tender details and download the document.




Tender Notice

40022843
Tender For Electrical And Allied Works For In-House Statutory Testing And Painting Unit And Degassing Unit With Fire Fighting System Works At Sekmai Bottling Plant
Limitted
Indian
Manipur
imphal
13-10-2023

Tender Details

Electrical And Allied Works For In-House Statutory Testing And Painting Unit And Degassing Unit With Fire Fighting System Works At Sekmai Bottling Plant => Limited

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document

BOQ Items

Name of Work : Electrical and allied works for In-house Statutory Testing and Painting unit and Degassing unit with fire fighting system works at Sekmai Bottling Plant
Sl. No. Item Description
1ELECTRICAL WORKS
2CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items
34 core x 2.5 sq mm copper cable FRLS
44 core x 16 sq mm Aluminium Cable FRLS
54 core x 6 sq mm Aluminium Cable FRLS
6Supplying, fabricating and installing following sizes of perforated GI cable trays including horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling and/or fix to steel/RCC columns, beams or any other structure members with MS suspenders, angles, channels, etc complete as per the direction of IndianOil
7100 mm x 25 mm x 2 mm
8200mm x 25mm x 2mm
9CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compresson cable glands, crimping type lugs and allied jointing materials, etc. all complete as per specification and direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used.
104 core x 2.5 sq mm
114 core x 6 sq mm
124 core x 16 sq mm
13FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination(FLP):Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of FLP heavy duty double compression cable glands, Baliga/CEAG-FCG/Flexpro/ FEPL make, crimping lugs and allied jointing materials, etc. all complete as per specification & direction of Engineer In-charge. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used.
144 Core x 2.5 sq. mm
154 x 25 sqmm
16Supplying and providing 100mm square hensel weather proof junction box for emblem pole/ light pole/yard light
17Area Light Poles Supply, erection and painting of area light poles of following types including 38/50mm dia tubular arm, MS base plate, earth boss, including concrete foundation (M15) of approx. size 0.5M x 0.5M and depth varying from 1.25M to 1.5M as per IS:2713 (Part II) and as per site condition, all complete as per site direction. Pole painting to be done with two coats red oxide primer and two coats of alluminium paint.
18S/E 7M long "DOUBLE ARM" Pole of designation 410-SP-3, as per specifications and direction of Engineer in charge
19Supply and fixing of 100 W LED (Light Emitting Diode) light fixture with fittings and accessories for Yard lighting purpose having IP66 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer-in-charge.
20MCB DISTRIBUTION BOARD INCLUSIVE OF 3- PHASE MCB Supply & fixing of MCB Distribution Board double door type inclusive of MCB, Three Phase, as per Approved Make of following types: S/E 6 way DB with 63A FP RCBO, 300 mA sensitivity as incoming - 1No. & 6 to 16A SP as outgoing - 6 Nos. for each phase.
21Supply & drawing/laying, jointing, connecting, testing and commissioning of earth strip/copper strip/GI wire for earthing and lightning protection under or aboveground complete as per specification for the following :
2232 x 6 mm G.I.strip
2350 x 6 mm G.I. Strip
24Providing earthing with 80 mm dia,3.0 M long GI (Heavy duty) perforated pipe as per IS:3043 (with latest ammendment) including providing suitable earth bus for interconnection, providing a mixture of salt & charcoal, making earth pit chamber with chequered plate cover as per standard Drwng. etc. all complete as per specif. & direction of Engineer-In-charge
25Cable Route Marker Supplying and installing of GI cable route marker with 100mm x 100mm x5mm thick GI Plate with inscription thereon, bolted/welded to 35mm x 35mm x 6mm angle iron, 600mm long and fixing the same in ground as per drawing & direction of IndianOil Job includes painting with one coat of redoxide & finishing paint.
26CABLE BRICK DUCT Providing & constructing underground brick duct 650mm below GL for laying of 3 cables of max. diameter 70mm, complete with supply and laying of sand, bricks & including Excavation and backfilling in all kind of soils. 450 mm (24 Bricks & 0.0494 cum per Mtr)
27Providing and laying class-B 50mm dia GI pipe for cable routing under flooring/ EB post leading including sealing both ends with jute and Bitumen
28Demolishing cement concrete manually/ by mechanical means including disposal of material outside premises at an unobjectionable place as per direction of Engineer-in-charge.
29Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: 1:3:6(1 Cement : 3 Coarse Sand: 6 Graded stone aggregate of 40mm)
30Supply and Installation of FLP Light fittings along with all accesories of approved make 80 Watt as per the direction of Engineer in Charge to achieve adequate lux level in proposed Degassing & ST&P shed
31FIRE FIGHTING SYSTEM WORKS
32Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil & disposal of surplus excavated soil as directed, within or outside the site at an unobjectionable place. All kinds of Soil
33Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level:1:3:6(1 Cement : 3 Coarse Sand : 6 Graded stone aggregate of 20mm)
34Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete:
35Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture.
36LAYING & WELDING 100 mm dia pipe above ground
37Fixing Double hydrant Points with individual head
38Supply of welded mild steel Pipeline heavy duty as per IS 1239 (upto 150 MM dia) AND IS 3589 (200 Mm and above Dia) as perspecifications and direction of IOCL."
39CS butterfly Valve 100mm dia (150#)
40Installation of Valves 100 mm dia
41Slip On flanges 100mm dia (150#)
42Welding of the flanges 100mm dia
43Making flanged joints 100 mm dia
44Supply of Gate Valve of 100 NB (150#)
45Supply & installation of Water monitors
46Fabrication and erection of Double Headed Hydrant Valve , including supplying and fixing 3mm thick gaskets/nuts/ studs, SS304 4mm thkOrifice plate to reduce the pressure as per design requirement and allother materials as per enclosed specifications and as directed at site.Note: The fittings shall be cleaned by hand cleaning or wire brushing and painted as per IOCl painting Specification.The rates quoted shouldinclude the same.Double hydrant Points (1x2Nos Single hydrant Points)
47Supply of forged MS fittings Bend- 90 degree L.R. forged bends as perASME B 16.5 made of A 234 WPB Gr. matching with pipeline thickness as per specification and direction of IOCL.
48Hydrostatic testing of piping works
49Radiography of pipline joints including all equipment, labours andconsumable items for completion of items. 100 mm Dia pipes joint
50DYE PENETRATION TEST FOR PIPING WORKS
51Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand or manufacture