Tender For Supply Of Various Type Of Test Kits And Consumables For Biochemistry Dept, Bikaner-Rajasthan

Medical College-MC has published Tender For Supply Of Various Type Of Test Kits And Consumables For Biochemistry Dept. Submission Date for this Tender is 25-10-2023. Cosmetics Tenders in Bikaner Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

40017437
Tender For Supply Of Various Type Of Test Kits And Consumables For Biochemistry Dept
Open Tender
Indian
Rajasthan
Bikaner
25-10-2023

Tender Details

Supply Of Various Type Of Test Kits And Consumables For Biochemistry Dept , Serum Sugar (Liquid Stable, Ready To Use, Linearity =700Mg/Dl, Kinetic) , Serum Urea-(Liquid, Ready To Use, Kinetic,Linearity =300 Mg/Dl , Serum Creatinine- (Liquid, Ready To Use, Kinetic, Linearity = 22 Mg/Dl) , Serum Total Protein- (Liquid, Ready To Use, End Point, Linearity = 15 G/Dl) , Serum Albumin- (Liquid,Ready To Use,End Point, Linearity = 7G/Dl) , Serum Total Cholesterol- (Liquid Stable,Ready To Use,End Point,Linearity =1000Mg/Dl) , Serum Triglyceride- (Liquid,Ready To Use, End Point, Linearity =1000Mg/Dl) , Serum Calcium- (Liquid Stable Ready To Use, End Point, Linearity = 15 Mg/Dl , Serum Phosphorus- (Liquid,Ready To Use,Linearity,=15Mg/Dl) , Serum Ggt- (Liquid,Ready To Use,Linearity =500U/L) , Serum Uric Acid- (Liquid, Stable Ready To Use,End Point, Linearity/Dl) , Serum Acid Phosphatase- (Liquid, Stable, Ready To Use,Kinetic, Linerity=75Iu/1) For Fully Auto Analyzer Supply With Calibrator And Control , Serum Creatine Phosphakinase (Ck-Nac/Cpk) (Liquid, Stable, Ready To Use,Linearity) , Serum Ck-Mb Kit With Calibrator & Control- (Liquid, Stable Or Lyophilised Reagent Reconstitution Stability 30 Days At 2-80 C Immunoinhibition Uv Kinetic Method, Linerarity =1000 U/L With Lyophilised Calibrator & Control Havig Reconstitution Stability = 7Days At 2-80C) , Serum Ldh- (Liquid, Stable Ready To Use,Kinetic, Linearity) , Amylase- (Liquid, Stable, Linearity Above) , Serum Acid Phosphatase- (Liquid Stable Ready To Use, Kinetic, Linearity =75 Iu/L - For Fully Auto (Supply With Calibrator)/Semiauto Analyzer(Supply With Standard) , Total & Direct Billirubin (Liquid Stable, Ready To Use, Fixed Time, Linearity=20 Mg/Dl) , Sgot-(Kinetic, Linearity = 300 Unit/Lt., Ifcc Method, Liquid Stable Reagent) , Sgpt- (Kinetic, Linearity = 300 Unit/Lt., Ifcc Method, Liquid Stable Reagent) , Alkaline Phosphatase- (Kinetic, Linearity = 1200 U/L, Ifcc Method) , Lipase (Liquid Stable, Ready To Use, Kinetic, Linearity =300 U/L) , Csf Microprotein (Liquid Stable, Ready To Use, Linearity =400 Mg/Dl) , Magnesium (Liquid Stable, Ready To Use, End Point) , Hdl-Cholesterol (Direct Clearance Method, Linearity =180 Mg/Dl. , Adenosine Deaminase- For Fully Auto Analyzersupply With Calibrator And Quality Control , Iron And Tibc , Csf Quality Control , Multi Calibrator For Fully Auto Analyzer (For Calibration Of Above Biochemical Parameters. Calibrator Should Be Traceable To Internationally Accepted Norms.Calibrator Will Run As Per Requirement Time To Time. , Multi Control For Fully Auto Analyzer (Control Of High, Normal/Low Will Run Daily) For Above Biochemical Parameters. Should Be Traceable To Internationally Accepted Norms. , Serum Total Cholesterol- (Liquid Stable,Ready To Use,End Point,Linearity =1000Mg/Dl) , Serum Triglyceride- (Liquid,Ready To Use, End Point, Linearity =1000Mg/Dl) , Total & Direct Billirubin (Liquid Stable, Ready To Use, Linearity =10 Mg/Dl, Preferably Single Reagent (Diazo With Sulphanilic Acid) , Serum Albumin- (Liquid,Ready To Use,End Point, Linearity = 7G/Dl) , Serum Total Protein- (Liquid, Ready To Use, End Point, Linearity = 15G/Dl ) , Hitachi Sample Cup, (Polystyrene, Highly Transparent, Non-Sticky, 17Mm X 38Mm Or 2Ml) , Disposable Test Tube (12 X 75Mm With Rim, 5Ml Capacity, Bottom Round, Autoclavable And Thermal Resistant, Highly Transparent , White Paper Laboratory Tissue Roll(For Cleaning Of Equipments, Pattern Plane And Should Be Thick And Not Leave The Rashes Or Fibers On Cleaning Surfaces) , Sodium Hypochlorite Solution (5-10% ) , Disposable Assay Tip On Rack (Tip Size 0-200 ?L)- Should Be Universal, Should Have Minimize Liquid Retention, Highly Transparent, Made Of Non-Sticky Material And Also Must Be Graduated Marking At Various Levels At 50, 100, 150 & 200. , Disposable Assay Tip On Rack (Tip Size 100-1000 ?L)- Should Be Universal, Should Have Minimize Liquid Retention, Highly Transparent, Made Of Non-Sticky Material And Also Must Be Graduated Marking At 100, 250, 500, 750 &1000?L. , Marker Pen Fine Tip (Red/Black, Usable On Glassware) , Filter Paper(24 Inches X24 Inches) , Aliquot For Quality Control And Calibrator Preparation (1.5 Ml) , Sample Transport Box With Carry Handle, (As Per Picture But Non-Transparent) • To Transport 13X75 Blood Collection Tubes For Sturdiness From Home Collection To Lab Or Hospital . Comes With Inbuilt Temperature Indicator. • Polycarbonate Construction And Available In Three Colors For User/Owner Identification • Silicone Water-Tight Seal And Three Lid Clasps Provide Secure Closure • Lid Opens A Full 180°, Allowing Total Access To Contents And Making It Easier To Clean • Will Accommodate 13 And 16 Mm Tubes In A Minimum 72-Place Onerack, Or Similar Sized • Use The Separators Provided To Create Your Own Compartment Sizes, Or Use Empty To Transport Larger Products And Equipment • Autoclavable , Hand Sanitizer (Liquid, Concentration Of Contains According To Who Guidelines) , Hand Wash (Liquid) , Blood Sample Collection Tube Size For Adult 7Ml Capacity - 1. Additive :- Serum Separating Gel (Ssg) And Clot Activator. (Gel Present At Bottom Of Tube And Should Be Stable In Physio-Chemical Variation And Avoid High Temperature Decomposition Or Molecules Precipitation). 2. Color Coding Of Cap :- Red In Colour (Screw Cap Preferred), Non-Vacutable Tube 3. Should Be Sterile, With Safety Closure And Single Hand Operation For Capping And Decapping. 4. Should Have Fill Mark To Indicate The Draw Volume. 5. Ce/Fda Certified. 6. Toxicity Certificate And Batch Wise Sterility/Pyrogenicity Certificate Should Be Provided. 7. The Tube Should Contain A Label For Noting The Patient’S Details. 8. Expiry Date Should Be Printed On The Tube.Shelf Life Should Be Minimum 12 Months Or More From The Date Of Manufacturing.

Key Value

Document Fees
INR 1000 /-
EMD
INR 200000.0 /-
Tender Value
INR 1 Crore /-

BOQ Items

Name of Work: Supply of Various type of Test Kits and Consumables for Biochemistry Department
Sl. No. Item Description
1Serum Sugar (Liquid stable, ready to use, Linearity =700mg/dl, Kinetic)
2Serum Urea-(Liquid, ready to use, Kinetic,Linearity =300 mg/dl
3Serum Creatinine- (Liquid, ready to use, Kinetic, Linearity = 22 mg/dl)
4Serum Total Protein- (Liquid, ready to use, End point, Linearity = 15 g/dl)
5Serum Albumin- (Liquid,ready to use,End Point, Linearity = 7g/dl)
6Serum Total Cholesterol- (Liquid stable,ready to use,End Point,Linearity =1000mg/dl)
7Serum Triglyceride- (Liquid,ready to use, End Point, Linearity =1000mg/dl)
8Serum Calcium- (Liquid Stable Ready to use, End Point, Linearity = 15 mg/dl
9Serum Phosphorus- (Liquid,ready to use,Linearity,=15mg/dl)
10Serum GGT- (Liquid,ready to use,Linearity =500U/L)
11Serum Uric Acid- (Liquid, Stable Ready to use,End Point, Linearity/dl)
12Serum Acid Phosphatase- (Liquid, Stable, Ready to use,Kinetic, Linerity=75IU/1) For fully auto analyzer supply with calibrator and control
13Serum Creatine Phosphakinase (CK-NAC/CPK) (Liquid, Stable, Ready to use,Linearity)
14Serum CK-MB Kit with Calibrator & Control- (Liquid, Stable or Lyophilised reagent reconstitution stability 30 days at 2-80 C Immunoinhibition UV kinetic method, Linerarity =1000 U/L with Lyophilised calibrator & Control havig reconstitution stability = 7days at 2-80C)
15Serum LDH- (Liquid, Stable Ready to use,Kinetic, Linearity)
16Amylase- (Liquid, Stable, Linearity above)
17Serum Acid Phosphatase- (Liquid stable Ready to use, Kinetic, linearity =75 IU/l - For Fully Auto (Supply with CALIBRATOR)/SemiAuto analyzer(Supply with STANDARD)
18Total & Direct Billirubin (Liquid stable, Ready to use, Fixed Time, linearity=20 mg/dl)
19SGOT-(Kinetic, Linearity = 300 unit/lt., IFCC method, Liquid Stable reagent)
20SGPT- (Kinetic, Linearity = 300 unit/lt., IFCC method, Liquid Stable reagent)
21Alkaline Phosphatase- (kinetic, Linearity = 1200 U/L, IFCC method)
22Lipase (Liquid stable, Ready to use, Kinetic, linearity =300 U/L)
23CSF Microprotein (Liquid stable, Ready to use, Linearity =400 mg/dl)
24Magnesium (Liquid stable, Ready to use, End Point)
25HDL-Cholesterol (Direct clearance method, Linearity =180 mg/dl.
26Adenosine deaminase- For Fully Auto Analyzersupply with calibrator and quality control
27Iron and TIBC
28CSF quality control
29Multi Calibrator for fully auto analyzer (for Calibration of above Biochemical Parameters. Calibrator should be traceable to Internationally accepted norms.Calibrator will run as per requirement time to time.
30Multi Control for fully auto analyzer (Control of high, normal/low will run daily) for above Biochemical Parameters. Should be traceable to Internationally accepted norms.
31Serum Total Cholesterol- (Liquid stable,ready to use,End Point,Linearity =1000mg/dl)
32Serum Triglyceride- (Liquid,ready to use, End Point, Linearity =1000mg/dl)
33Total & Direct Billirubin (Liquid stable, Ready to use, Linearity =10 mg/dl, preferably single reagent (Diazo with Sulphanilic acid)
34Serum Albumin- (Liquid,ready to use,End Point, Linearity = 7g/dl)
35Serum Total Protein- (Liquid, ready to use, End Point, Linearity = 15g/dl )
36Hitachi Sample Cup, (Polystyrene, highly transparent, non-sticky, 17mm x 38mm or 2mL)
37Disposable Test Tube (12 x 75mm with Rim, 5ml capacity, Bottom Round, Autoclavable and Thermal Resistant, highly Transparent
38White Paper Laboratory Tissue Roll(for Cleaning of Equipments, Pattern Plane and should be thick and not leave the rashes or fibers on cleaning surfaces)
39Sodium hypochlorite solution (5-10% )
40Disposable Assay Tip on Rack (tip size 0-200 µl)- Should be Universal, should have minimize liquid retention, highly transparent, made of non-sticky material and also must be graduated marking at various levels at 50, 100, 150 & 200.
41Disposable Assay Tip on Rack (tip size 100-1000 µl)- Should be Universal, should have minimize liquid retention, highly transparent, made of non-sticky material and also must be graduated marking at 100, 250, 500, 750 &1000µl.
42Marker Pen Fine Tip (Red/Black, usable on glassware)
43Filter Paper(24 inches x24 inches)
44Aliquot for quality control and calibrator preparation (1.5 ml)
45Sample Transport Box with carry handle, (as per picture but Non-transparent) • To transport 13x75 blood collection tubes for Sturdiness from home collection to lab or hospital . Comes with inbuilt temperature indicator. • Polycarbonate construction and available in three colors for user/owner identification • Silicone water-tight seal and three lid clasps provide secure closure • Lid opens a full 180°, allowing total access to contents and making it easier to clean • Will accommodate 13 and 16 mm tubes in a minimum 72-place OneRack, or similar sized • Use the separators provided to create your own compartment sizes, or use empty to transport larger products and equipment • Autoclavable
46Hand Sanitizer (Liquid, concentration of contains according to WHO guidelines)
47Hand wash (Liquid)
48Blood Sample Collection Tube Size for Adult 7ml capacity - 1. Additive :- Serum Separating Gel (SSG) and Clot Activator. (Gel present at bottom of tube and should be stable in physio-chemical variation and avoid high temperature decomposition or molecules precipitation). 2. Color Coding of Cap :- Red in colour (Screw cap preferred), Non-vacutable tube 3. Should be sterile, with safety closure and single hand operation for capping and decapping. 4. Should have fill mark to indicate the draw Volume. 5. CE/FDA certified. 6. Toxicity Certificate and Batch wise sterility/pyrogenicity certificate should be provided. 7. The tube should contain a label for noting the patient’s details. 8. Expiry date should be printed on the tube.Shelf life should be minimum 12 months or more from the date of manufacturing.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail