Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | EARTH WORK.Earth work in excavation by mechanical means (Hydraulic excavator )/manual means over areas(exceeding 30cm in depth, 1.5 m in which as well as 10 sqm on plan) including geting out and disposal of excavated earth lead upto 50 m and liftupto 1.5 m, as directed by Engineer in charge.All kinds of soil |
| 2 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 3 | Excavating, supplying and fitting and local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc.complete |
| 4 | PLAIN CEMENT CONCRETE WORKS.Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate (12.5mm nominal size) |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 40 mm nominal size) |
| 6 | 1:4:8(1 Cement: 4coarse sand(zoneIII) derived fromnatural source : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 7 | Making plinth protechtion 50mm thick of cement concrete 1:3:6(1 cement :3 coarse sand(zone-III)derived from natural sources : 6 graded stone aggregate 20mm nominal size derived from natural sources) over 75mm thick bed of dry brick basllast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, leveling & dressing & finishing the top smooth. |
| 8 | REINFORCED CEMENT CONCRETE WORKS.Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) |
| 9 | 1: 2: 4 (1 cement :2 coarse sand(zone-III) derived from natural sources: 4 graded stone aggregate 20mm nominal size derived from natural sources) |
| 10 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 11 | Porland/Potland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate/rated setting of concrete, to improve durability and workability without impairing strength, including pumping of concrete to site of laying, curing, carriage for all leads, but excluding the cost of centering , shuttering, finishing and reinforcement as per direction of the engineer -in charge, for following grades of concrete. Note: extra cement up to 10% of the minimum specified cement contentin design mix shall be payable separately. In case the cement content in desgn mix is more than 110% of the spesified minimum cement content, the contactor shall have discretion to either re-desgn the mix or bear the cost of extra cement.All works up to plinth level.Concrete of M25 grade with minimum cement content of 330kg/cum |
| 12 | All works above plinth level up to floor V level.Concrete of M25 grade with minimum cement content of 330kg/cum |
| 13 | FORMWORK.Centering and shuttering including strutting, propping ect. and removal of form work for:oundations, footings,bases of columns, etc. for mass concrete |
| 14 | Suspended floors, roofs, landings,balcolonies and access platform. |
| 15 | Lintels,- beams, plinth beams, girders, bressumers and cantilevers. |
| 16 | Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 17 | Stairs,(excluding landings) except spiral-staircases |
| 18 | MASONARY WORK.Brick work with common burnt clay F.P.S.(non modular) bricks of class designation 7.5 infoundation and plinth in:Cement mortar 1:4(1 cement : 4 coarse sand) |
| 19 | Cement mortar 1:6(1 cement : 6 coarse sand) |
| 20 | Half brick masonry with common burnt clay F.P.S (non modular) briks of class designation 7.5 in foundations and plinth in: Cement mortar 1:4(1 cement : 4 coarse sand) |
| 21 | Half brick masonary with common burnt clay F.P.S.(non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level.Cement mortar :1:4 (cement : 4 coarse sand) |
| 22 | Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonary. |
| 23 | STONE WORK(CLADDING & FLOORING ).Providing and fixing 18 mm thick gang saw cut,mirror polished, premouled and prepolished, machine cut for kitchen platforms, vanity couners, window sills, facias and similar locations of required size, approved shede, colour and texture laid over 20mm thick base cement mortar 1:4(1 cement :4 coarse sand), joints treated with white cement, mixed with matching pigment,epoxy touch ups,inluding rubbing curing, moulding and polishing to edges to give high gloss finish etc. complte at all levels.Granite stone slab colour black, cherry/Ruby red. Area of slab over 0.50 Sqm |
| 24 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer- in-charge.Granite work |
| 25 | Extra for fixing marble/ granite stone, over and above corresponding basic iteam, in facia and drops of width upto 150 mm with epoxy resin based adhesive, inluding cleaning etc. complete. |
| 26 | Providingand fixing 1st quality ceramic glazed wall tiles confrming to IS: 15622(thickness to be specified by the manufactureer), of approved make, in all colours, shades except burgundy bottle green, black of any size as approved by Engineer-in-charge, in skarting risers of steps and dados,over 12mm thick bed cement mortar 1:3(1 cement :3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 27 | WOOD AND ALLUMINIUM WORK.Providing wood work in frames of Doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & lenth (hold fast lugs or dash fasteners shall be paid for separately)Second class teak wood |
| 28 | Poviding and fixing ISI marked flush door shutters conforming to IS: 2202 (part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with verticle grains or cross bands and face veneers on both faces of shutters.35 mm thick including ISI marked stainless Steel butt hinges with necessary screws |
| 29 | Extra for providing lipping with 2nd clas teak wood battens 25mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured) |
| 30 | Extra for cutting rebate in flush door shutters (total area of the shutter to be measured) |
| 31 | Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete:2nd class teak wood 50 x 20mm |
| 32 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden flugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement:3 coarse sand: 6 graded stone aggregate 20mm nominal size) |
| 33 | Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc.complete: 300x16 mm |
| 34 | Providing and fixing chromium plate brass handles with necessary screws etc. complete :125 mm |
| 35 | Providing and fixing aluminium sliding door bolts, ISI marked anodised ( anodic coating not less than grade AC 10 as per IS:1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete:300x16 mm |
| 36 | Providing and fixing aluminium hanging floot door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS:1868), transparent or dyed to required colour andshade, with necessaryscrews etc. complete: Twin rubber stopper |
| 37 | Providing and fixing aluminium work for doors, windows,ventilators and partition with extruded built up standard tubular sections/appropriat Z sections and other sections of approved make conforming to IS:733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e.at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Alumunium sections shall be smooth, rust free,straight, mitred and jointed mechanically- wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/stainless steel screws, all mplete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for sepatrately):For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and making provision for fixing and fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately)Anodisedaluminium ( anodised transparent or dyed to required shade according to IS:1868, minimum anodic coating of grade AC 15) |
| 38 | Providing and fixing glazing in aluminium door, window, ventilators shutters and partitions etc. with EPDM rubber/neoprene gasket etc. Complete as per the architectural drawings and the directions of engineer-in-charge. Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness(weight not less than 10kg/sqm |
| 39 | STEEL WORK.Steel work welded in built up sections/framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc.as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 40 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and flitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of engineer-in-charge,(for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts,fasteners etc.) |
| 41 | STEEL REINFORCEMENT.Steel reinforcement for R.C.C work including straightening, cutting , bending, placing in position and binding all complete up to plinth level.Thermo-Mechanically Treated bars of grade Fe-S00D or more. |
| 42 | Steel reinforcement for R.C.C. work including straightening, cutting, binding placing in position and binding all complete above plinth level.Thermo Mechanically Treated bars of grade Fe-S00D or more. |
| 43 | FLOORING.Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to SI:15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1: 4:(1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigment etc,complete size of Tile 600x600 mm |
| 44 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08%and conforming to IS:15622, of approved brand & manufacture, in allcolours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement:4 coarse sand)joining with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier,wedge,clips of required thickness, leveling system and rubber mallet for placeing the tiles ently and easily.Glazed Vitrified tiles Matt/Antiskid finish of size.Size of the Tile 600x600 mm |
| 45 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zic coating of 120 gms/sqm(both side inclusive)as per IS:277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm,at 1200 mm centre to cetre, one flage fixed to the ceiling with dash fastener 12.5 mmdiax 50 mm long with 6 mm dia bo;ts, other flange of cleat fixed to the angle hangers of 25x 10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermsdiate G.I, channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm diax230mm long G.I. wire at every junction, including fixing perimmeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30mm long the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre,with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish to tapered and square edges of the board with recommended jointing compund, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer\"s specification and also including the cost of making openings for light fittings,grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in charge but exluding the cost of painting with:12.5 mm thick tapered edge gypsum plain boardconforming to IS:2095-(part-I): 2011(Board with BIS certification marks) |
| 46 | 12.5 mm thick tapered edge gypsummoisture resistant board. |
| 47 | FINISHES.12 mm cement plaster of mix:1:4 (1 cement : 4 fine sand) |
| 48 | 15 mm cement plaster on the rough side of single or half brick wall of mix.1:4 (1 cement : 4 fine sand) |
| 49 | Applying Priming Coat.With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works. |
| 50 | Paining with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:Two or more coats on new wood over an under coat of suitable shade with ordinary paint of approvedbrand and manufacture |
| 51 | Providingand appying white cement based putty of average thickness 1 mm, of approved brand and manufacturer. Quote for each layer over the plastered wall surface to prepare the surface even and smooth complete. |
| 52 | New work (two or more coats) over and inclding water thinnable priming coat with cement primer. |
| 53 | New work(two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm) |
| 54 | white washing with lime to give an even shade:New work (three or more coats) |
| 55 | 100 mm nominal dia pipes |
| 56 | MANHOLE COVER.Providing and fixing in position pre-cast RCC manhole cover and frame of required shape and approved quality.LD-2.5 Circular shape 450 mm internal diameter |
| 57 | ROOFING WORK.Providing corrugated G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat at approved steel primer andtwo coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape whereverrequired.0.63 mm thick with zinc coating not less than 275 gm/m2 |
| 58 | Proving ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymercoatedJ & L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.0.63 mm thick with zinc coating not less than 275 gm/m2 |
| 59 | Providing valleys of 90 cm wide overall in plain G.S sheet fixed with polymer coated J and L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.1.60 mm thick with zinc oating not less than 350 gm/m2 |
| 60 | Providing valleys of 90 cm wide overall in plain G.S sheet fixed with polymer coated J and L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.Providing and fixing precoated galvanized steel sheet roofing accessories- 0.50 mm (+0.50%) total coated thickness , Zinc coating 120 grams per sqm as per IS:277, in 240 mpa steelgrade , 5-7 microns epoxy primer on both sideof the steel and polyester top coat 15-18 microns using self drilling/self tapping screws complete.Barge board(up to 300 mm) |
| 61 | WATERPROFING.Providing and layingwater proofingtreatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying.(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm.This layer will be allowed to air cure for 4 hours.(b) Second layer ofslurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. Thislayer will be allowed to air cure for 4 hours following with water curing for 48 hours.(The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry) |
| 62 | Providing and laying integral cement based water proofing treatment including preparationof surface as required for treatment of roofs, balconies, terraces etc. consisting of following operations: (a) Applyinga slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound coforming to IS:2645and approved by Engineer in charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying bricks bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS:2645 and approved by Engineeri-in charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS:2645 and approved by Engineer -in-charge to required slope and treating similarly the adjoining walls upto 300mm height including rounding of junctions of walls and slabs.© After two days of proper curing applying a second coat of cement slurry using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS:2645 and approved by Engineer in-charge.(d)Finishing and surface with 20 mm thick jointless cement mortar of mix 1:4 ( 1 cement : 4 coarse sand) admixed with water proofing compound .(e)The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test,\"All above operations to be done in order and directed and specified by tne Engineer in-charge:With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 63 | Constructing soak pit 1.20 x1.20x1.20 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. |
| 64 | INTERNAL SANITARY WORKS.Providing and fixingvitreous china dual purpose closet suitable for use as squatting pan or European type water closet (Western W.C. pan) with seat & lid fixed with C.P. brass hinges and rubber buffers, 10 litre low level flushing cistern with fitting and brackets, 40 mm flush bend, 20 mm over flow pipe, with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: White vitreous china dual purpose WC pan with white solid plastic seat and lid with white vitreous china flushing cistern and C.P. flush bend. |
| 65 | Providing and fixingwhite vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern ,with fittings, standard size CP brass flush pipe, spreaders with unions and clamps (all in CP brass) with waste fitting as per IS: 2556, CI. trap with cutlet grating and other coupling in C.P. brass, includingpainting of fittings and cutting and making good with the walls and floorswherever required: Single half stall urinal with 5 litre P.V.C. automatic flushing cistern. |
| 66 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting og fittings and brackets, cutting and making good the walls wherever require: White Vitreous China wash basin size 630 x450 mm with a single 15 mm C.P. brass pillar tap. |
| 67 | Providing and fixing toilet paper holder C.P. brass |
| 68 | Providing and fixing 8 mm dia C.P./S.S. Jet with flexible tube upto 1 metre long with S.S. traingular plate to Eureopean type W.C. of quality and make as approved by Engineer in charge. |
| 69 | Providing and fixingStainless Steel A ISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required: Kitchen sink with drain board 510x1040 mm bowl depth 250mm |
| 70 | Providing and fixing unplasticised P.V.C.connection pipe with PTMT nuts, collar and bush of approved quality and colour, 15 mm nominal bore with 45 cm length. |
| 71 | Providing and fixing CP brass long nose bib cook of approved qualityconforming to ISstandards and weighing not less than 810 gms. 15 mm nominal bore. |
| 72 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931, 15 mm nominal bore. Providing and fixing PTMT pillar cock of approved quality and colour. |
| 73 | 15 mm nominal bore, 125 mm long foam flow,weighing not less than 120 gms |
| 74 | Providing and fixing600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 75 | Providing and fixingPTMT liquid soap container 109 mm wide,125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 76 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long , 200 mm wide with minimun distances of 37 mm from wall face withconcealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. |
| 77 | Providing and fixing PTMT bottle trap for wash basin and sink. Bottle trap 31 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25mm minimum water seal, weighing not less than 260 gms. |
| 78 | Providing and fixing PTMTgrating of approved qualityand colour.18.58.1 Circular type, 18.58.1.1 100 mm nominal dia |
| 79 | Providing and fixing PTMT soap Dish Holder having length of 138 mm, breadth 102 mm, height of 75 mm with concealed fitting arrangments, weighing not less than 106 gms. Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS: 15801 UV stabilized &anti-microbial fusion welded, having thermal stability for hot & cold water supply, including all PP-R plain and brass threadedpolypropylene random fittings, including trenching, refilling & testing of joints complete as per direction of Engineer- in-charge. |
| 80 | EXTERNAL WORK. PN-10 Pipe, 110 mm OD (SDR-11) |
| 81 | PN-10 Pipe, 90mm OD (SDR-11) |
| 82 | PN-10 Pipe, 75 mm OD (SDR-11) |
| 83 | PN-10 Pipe, 63 mm OD (SDR-11) |
| 84 | PN-10 pipe, 50 mm OD (SDR-11) |
| 85 | PN-16 pipe, 40 mm OD (SDR-7.4). Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS: 15801 UV stabilized &anti-microbial fusion welded, having thermal stability for hot & cold water supply, including all PP-R plain and brass threadedpolypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includestesting of joints complete as per direction of Engineer- in-charge. |
| 86 | Internal Exposed on wall. PN-16 pipe, 32 mm OD (SDR-7.4)Providing and fixing 3 layer PP-R(Poly propylene Random copolymer) pipes confirming to IS: 15801, UV stabilized &anti-microbial fusion welded, having thermal stability for hot & cold water supply, including all PP-R plain and brass threadedpolypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includesthe cost of cutting chases and making good the same including testing of jointscomplete as per direction of Engineer- in-charge. Concealed work, including cutting chases and making good the wall etc. |
| 87 | PN-16 pipe, 20 mm OD (SDR-7.4) |
| 88 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS: 13592 type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 89 | 75 mm diameter. Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, Bend 87.5\" |
| 90 | 75 mm bend. Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving10 mm gap for thermal expansion shoe plain. |
| 91 | 75 mm shoe. DEEP TUBWELL. Boring/ drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part-I),including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer in charge, up to 90 metre depth below ground level.All types of soil |
| 92 | 300 mm dia. Supplying , assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforing to IS: 12818,including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer in charge. |
| 93 | 100 mm nominal size dia. |
| 94 | 150 mm dia nominal size dia. Providing and fixing Chlorinated polyvinyl chloride(CPVC) pipes, having thermal stability for hot &cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refiling & testing of joints complete as per direction of Engineer in charge.(SUCTION PIPE) |
| 95 | EXTERNAL WORK. 40 mm nominal outer dia Pipes |
| 96 | Providing and placing in position filters of 40 mm diameter G.I./PVC pipe with brass strainer of approved quality. Providing and fixing gun metal non-return valve of approved quality(screwed end): |
| 97 | Horizontal |
| 98 | Vertical |
| 99 | Development of tube well in accordance with IS:2800 (Part-I) and IS:11189, to establish maximum rate of rusable water yield without send content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully devoloped, measuring yield of well by \"V\" notch method or any other approved method, measuring static level & draw down etc.by step draw down method, collecting water samples & getting tested in approved laboratory,i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc, all as per requirement and direction of Engineer in charge. Providingand fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removaled as per reqirement, all complete for borewell of09-03-2023 |
| 100 | 100 mm dia |
| 101 | 150 mm dia. Providing and fixing M.S. clamp of required dia to the top of casting/housing pipe of tubwell as per IS:2800 (Part I), including necessary bolts and nuts of the required size complete. |
| 102 | 150 mm clamp.Providing and fixing Bail plug/Bottom plug of required dia to the |
| 103 | 100 mm dia |
| 104 | 150 mm dia |
| 105 | Gravel packing in tubwell construction in accordance with IS: 4097, including providing gravel fine/medium/coarse, in required grading & sizes as per actual requirement,all complete as per direction of Engineer in charge. |
| 106 | Supplying including installation, connection as approved by the Deptt, testing and commissioning of SUBMERSIBLE PUMP SET 3 (three phase)withsteel cable rope and submersible cable complete as directed and specified by the deptt.Three phase submersible motor pump set(Texmo/Crompton Greaves/Aquatic/CRI/V-Guar suitable for 100 mm bore well and above. 1 HP STAGE 5 to 18 with MCB controlled submersible motor pump set control panel. |
| 107 | Supplying including installation, connection as approved by the Deptt, testing and commissioning of JETPUMP SET (HORIZONTAL) complete as directed and specified by the deptt. 1 HP single phase Jet pump set(Horizonal(Cromton Greaves/Aquatic/CRI/V-Guard make) 2900 rpm with DOL starter (Crompton Greaves/Control & Switch Gear/BCH/L & T/Siemens make) |
| 108 | INERNAL ELECTRICAL WORKS. Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earting the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc.as required. Group B |
| 109 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitalbe GI box and earthing the point with1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc.as required. Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper |
| 110 | 2x15 sq.mm +1x1.5 sq.mm earth wire |
| 111 | 2 x 2.5 sq.mm +1 x2.5 sq.mm earth wire |
| 112 | 2 x 4 sq.mm +1 x 4 sq.mm earth wire |
| 113 | 3 x 6 sq.mm +1 x 6 sq.mm earth wire |
| 114 | Supplying and drawing co-axIal TV cable RG-6 grade,0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the sxisting surface/recessed steel/ PVC conduit as required. Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. |
| 115 | 100 mmx 100mmx60 mm deep. Supplying and fixingfollowingmodular switch/socket on the existing modular plate & switchbox including connections but excluding modular plate etc. as required. |
| 116 | 5/6 A switch |
| 117 | 2 way 5/6 A switch |
| 118 | 15/16 A switch |
| 119 | 3 pin 5/6 A Socket |
| 120 | 6 pin 15/16 A socket |
| 121 | TV antenna socket outlet |
| 122 | bell push |
| 123 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch boxincluding connections but existing modular plate etc. as required. |
| 124 | Supplying and fixingmodular blanking plate on theexisting modular plate & switch boxincludingmodular plate as required.Supplying and fixingfollowing size/modules,GI box alongwith modular base & cover plate formodular switches in recess etc.as required. |
| 125 | 3 Module (100mmx 75mm) |
| 126 | 4 Module (125mmx 75mm) |
| 127 | 6 Module (200mmx 75mm) |
| 128 | 8 Module (125mmx 125mm) |
| 129 | 12 Module (200mmx 150mm) .Supplying and fixingfollowing Modular base & cover plateon theexisting modular metal boxes etc. as required. |
| 130 | 3 Module |
| 131 | 4 Module |
| 132 | 6 Module |
| 133 | 8 Module |
| 134 | 12 Module |
| 135 | Supplying and fixingsuitable size GI box with modular plate and cover in front on the surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc.as required. |
| 136 | Supplying and fixingsuitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 Amodular socket outlet and 15/16 A modular switch, connections etc.as required. |
| 137 | Supplying and fixing brass batten/angle holder including connection etc. as required. |
| 138 | Installation testing and comissioning of prewired, flouriscent fitting/compact flouriscent fitting of all typs, complete with accessories and tube/lamp directly on ceiling/wall including connection with 1.5 sq.mm FRLS PVC insulated, copper ,conductor single core cable and earthing etc.as required. |
| 139 | Installation testing and comissioning ofceiling fan, including wiring the down rods of standard length 30 cm with 1.5 sq.mm FRLS PVC insulated, copper ,conductor single core cable as required. |
| 140 | Installationof exhaust fan in the existing opening including making good the damages, connection, testing and commissioning etc. as required. 450 mm sweep. Supplying and fixingfollowing way, single pole and neutral, sheet steel, MCB distribtion board, 240 V, on surface / recess, complete wit tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc.as required.(But without MCB/RCCB/Isolator) |
| 141 | 12 way, Double door.Supplying and fixingfollowing ways surface/recess mounting, vertical type, 415 V, TPN MCB distribution board of steel sheet, dust protection, duly power- painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs ( but without MCBs and incomer) as required. (Note: Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 142 | 4 way(4+ 12), Double door.Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 KA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the exising MCB DB complete with connections, testing and commissioning etc. as required. |
| 143 | Single pole |
| 144 | Double pole. Supplying and fixingfollowing rating , double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc.as required. |
| 145 | 40A. Supplying and fixingfollowing rating , four pole, (three phase and neutral), 415 Volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc.as required. |
| 146 | 63A. |
| 147 | Supplying and fixing 20 amps, 240 volts,SPN industral type, socket outlety, with 2 pole and earth, metal inclused plug top alongwith 20 amps\"C\" curve,SP, MCB,in sheet steel enclusure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 148 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclusure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. |
| 149 | Earthing with G.I. earth plate600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclusure with cover plate having locking arrangement and watering pipe etc.of 2.7 metre long etc. with charcoal/coke and salt as required. |
| 150 | Supplying and laying 6 SWG GI wire at 0.50 metre below ground level for conductor earth electrode, including connection/termination with GI thimble etc as required. |
| 151 | Providing and fixing of lightning coductor finial, made of 25 mm dia long, GI tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 152 | Above 35 sq.mm and upto 95 sq.mm. Supplying and makingend termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 153 | 3 1/2 x 70 sq.mm(38mm). Supplying and making outdoorend termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulatedand PVC sheathed/XLPEaluminium conductor cable of 1.1 KV grade as required. |
| 154 | 3% x 70 sq.mm(38mm). |
| 155 | Instalation, testingand commissioning of prewired fluorescent fitting compact fluorescent fitting of all types complete with all accesssories and tube/lamp etc. directly on ceiling/wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 156 | Instalation, testingand commissioning ofceilin fan, including wiring the down rods of standard length (upto 30cm) with 1.5sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing including providing and fixing phenolic laminated sheet cover on the fan boxetc. as required. |
| 157 | Numberingof ceiling fan/exhaust fan/fluorescent fitting as required. Installation of exhaust fan in the exising opening, including making good the damages, connection , testing and commissioning etc. as required. |
| 158 | Upto 450mm sweep. Providing laying and fixingfollowing dia G.I. pipe(medium class) in ground complete with GI fitting including trenching(75cm deep) and re-filing etc. as required. |
| 159 | 80 mm dia . Providingand fixingfollowing capacity TP & N disconnector fuse switch unit inside the exisingpanel board with IS marked HRC fuses including driling holes in cubicle panel, making connections, etc. as required. |
| 160 | 63 Amp TP & N. Providingand fixing following rating and breaking capacity and pole MCCB in exising cubicle panel board including drilling holes in cubicle panel, mixing connections etc.as required. |
| 161 | 160 Amp,16 KA, TP MCCB. Supplying of following size XLPE insulated and PVC sheathed aluminium conductor armoured power cable of 650/1100 V grade conforming to IS 7098 (part-I)/ 1988 with amendment upto date etc.as required. |
| 162 | 3 1/2 Corex 70 sqmm aluminium.Supplying including installation, commissioning of vermin and dust proof totally enclosed, Phosphatised powder Painted cubical indoor type floor/wall mounting compartmentalize panel board of size 0.95 M(B)X 2.30M(H)X 0.40M(D) made of 16 SWG (1.66mm) thick C.R. sheet and 40mmx40mmx5mm size angle having 4 nos legs at the bottom. The panel board is to be errected in 1:3:6 PCC foundation including brick soling/ grounting etc. complete neatly wiring done with provision for one no 160A 4pole MCCB or Switch Fuse Unit as incomer and provision for 6nos DP or TPN out going as specified and directed by the deptt. confirming to IP 43 protection comprising of the following electrical items: 1.i) 40mmx 5mm 4 strip copper Bus-Bar 1.20M length each.ii) 20mmx 3mm 4 strip copper Bus -Bar 0.5 M each 4 sets.2. Poilt Lamp with integral ckt LED 110-230 V(Red,Yellow, & Blue)-3nos. 3. Voltmeter & Ammeter Selector Switch -2 nos .4. 2 A Slide fuse unit-3nos |
| 163 | Incoming & Outgoing Switch Gear of required rating along with Meters will be measured and paid separately) |
| 164 | EXTERNAL ELECTRIFICATION.Earthing with GI earth plate 600mmx 600mm x 6mm thick including accessories, and providing and masonryendclusure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/coke and solt as required. |
| 165 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 166 | upto 120sq.mm. Providing and fixing following rating and breaking capacity and pole MCCB in exising cubicle panel board including driling holes in cubicle panel, making connections, etc.as required. |
| 167 | 250Amp, 25 KA, TPMCCB. Providing and fixingfollowing capacity TP &Ndisconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. |
| 168 | 63 Amp TP & N. Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 1.1KV grade as required. |
| 169 | 70 sqmm. Supplying and making outdoorend termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulatedand PVC sheathed/XLPEaluminium conductor cable of 1.1 KV grade as required. |
| 170 | 3 1/2 X95 sq.mm. Supplying and making straight through joint with heat shribnksable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 171 | 3 1/2 x 95 sq.mm. Erection of matellic pole of following length in cement concrete 1:3:6 (1 cement :3 coarse sand :6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc.as required. |
| 172 | Above 10.00 metre and upto 12 .00 metre. |
| 173 | Supplying and erection of stay set complete (galvanised) with 19/20 mm dia x 1.8 metres long stay rod, anchor plate of size 45 cm x 45 cm x7.5 mm, thimble, stay clamps, turn buckle (20 mm x60 cm),7/4.00 mm dia G.I. stay wire and strain insulator etc.in cement concrete 1:3:6 ( 1 cement: 3 coarse sand :6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. |
| 174 | Supplying and erection of 30 A aerial fuse complete as required. |
| 175 | Erection of aerial fuse as required. |
| 176 | Supplying and fixingMV horn gap lightning arrestor as required. |
| 177 | Fixing of MV lightning arrestor as required. |
| 178 | Erection of angle iron/ channel iron cross arm on wood/RCC/steel tubular/rail pole etc. as required. |
| 179 | Supplying and erection of galvanised \"D\" iron clamps complete with shackle insulator (75 mmx 90 mm),G.I. bolts and nuts washers, coach screws etc. as required. |
| 180 | Supplying and fixingof 32 mm dia x2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent/HPMV/HPSV steet light fitting on pole including bending the pipe to the required shape, 2 nos40 mm x 3 mm flat iron claps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. |
| 181 | Erection of disc/pin insulator for 11 KV over head lines as required. |
| 182 | Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11KV overhead lines with rated voltage 9 KV( rms) with a nominal discharge current rating of 5 KV and complete with galanised clamping arrangement, G.I.bolts, nuts, washers rtc. as required. |
| 183 | Supplying ,installation testing and commissioning of the- 100 KVA Aluminium wound indoor/outdoor type transformer complete including the payment to the made to power supply authority for supervision charge, labour charge, cost of LT/HT metering etc.(excluding the cost ofload security)and making necessary arrangement for charging approvalof the sub-station from the competent authority as directed and specified by the deptment. Transformer should be as per CEA guidelines as ammended up to date up to 200 KVA star rating up to 5 star, above 200 KVA as per CEA guidelines for losses along with LV enclosure. Supplying of following size XLPE insulated ,insulation screening with extruded semi conducting compound incombination with copper tape cores laid up inner sheath of PVC tape, galvanised flat steel strip armoured anf over all PVC sheathed cable confirming to I.S. 7098(part-II)1985 with latest amendments |
| 184 | 3CX95sqmm HT. Supplying of following sizes G.I. pole confirming to IS. 2713 |
| 185 | 12 Mtr(SP-66) |
| 186 | Supplyingand drawingof 11KV overhead high tension line through Racoon conductor on the existing polestruture with necessary binder pin, cross arm etc. as required complete. |
| 187 | Supplying includinginstallation, testing and commissioning of 62.5 KVA Air/water Cooled Diesel Generator set coupled to suitable alternator of 220/415 V,AC. 1/3- phase 0.8 p.f.(la mounted on a 1) M.S. Fabricated base frame,2) M.S fuel tank of required capacity,3) Residual Silencer,4) Standard Control panel,5) Suitable batteries with lead,5) First fill of tube oil,6) Acoustic Enclosure complete with all accessories as specified and directed by the department conforming to IS comprising the Technical SpecIfication,as per manufacturer.Supplying includinginstallation, commissioning ofvermin and dust proof totally enclosed, phosphatised powder Painted cubical indoor type floor/wall mounting compartmentalize panel board of size 0.95 M(B) X 1.30 M(H)X 0.40 M(D) made of 16 SWG (1.66 mm) thick CR sheet and 40mm x 40 mmx 5mm size angle having 4 nos legs at the bottom. The panel board is to be errected in 1: 3 :6 PCC foundation including brick soiling/ grouting etc. complete neatly wiring done withprovision for one no 250A 4pole MCBor switch fuse Unit as incomer and provision for 8 nos DP or TPN outgoingas specified and directed by the deptt. conforming to IP 43 protectioncomprisingof thefollowing electrical items.1. i)40mmx 5mm 4 strip copper Bus-Bar 1.20 M length each. ii) 20 mmx 30mm 4 srtrip copper Bus-Bar 0.5 M each 4 sets.2 Poilt Lamp with integral ckt LED 110-230 V(Red, Yellow & Blue)-3 nos. 3.Voltameter & Ammeter Selector Switch- 2 nos.4.2A Slide fuse runit- 3nos. |
| 188 | ( Incoming and outgoing Switch Gear of reqd. rating along with Meters will be measured and paid separately) |
| 189 | Payment of load security to the local APDCL authority. |
| 190 | SIDE DEVELOPMENT.Surface dressing of the ground including removing vegetation and inequalities not exceding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil |
| 191 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including remmaining and watering of the earth in layers not exceeding 20 cm in trenches,plinth, sides of foundation etc.complete |
| 192 | Peparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and cosilidating with roadroller including making good the undulation etc. and re-rolling the sub-grade and disposal of surplus earthwith lead upto 50 meters. |
| 193 | Laying ,spreading and cpmpactingstone aggregate of specified sizes to WBM specifications in unifrm thickenss, hand picking, rolling with 3 wheeled road/vivratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening/ binding material to fill up intersitices of coarse aggregate, watering and compacting to the required density. |
| 194 | With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 |
| 195 | Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-130 made by block making machine with strong vibratory compaction, of approve size, design & shape, laid in required colour ang pattern over and including 50 mm thick compactedbe of coarse sand, filling the joints with line sand etc.- all completed as per the direction of Engineer in charge. |
| 196 | BOUNDARY WALL. Earth work in excavation by Mechanical means(Hydraulic excavator/menual means over areas(exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift up to 1.5 n, as directed by Engineer- in charge. All kinds of Soil. |
| 197 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 198 | CEMENT CONCRETE WORKS.Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6( 1 cement : 3 coarse sand(Zone-III) : 6 graded stone aggregate 40 mm nominal size) |
| 199 | Povidingand laying damp-proof course 40mm thick with cement concrete 1:2:4(1 cement : 2 coarse sand (zone-III) : 4graded stone aggregate (12.5 mm nominal size). Providing and lying in posision specified grade of reinforced cement concrte, excluding the cost of centering ,shuttering, finishing and reinforcement All work up to plinth level: |
| 200 | 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size). Reinforced cement concrte work in walls(any thickness), including attached pilasters,buttresses, plinth and string courses, fillets, colunms, pillars, piers, abutments, posts and struts etc. above plinth level up tofloor five level, excluding cost of centering, shuttering finishing and reinforcement: |
| 201 | 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) |
| 202 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 25 mmx 25 mm made of G.I wire of dia 3 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer in charge. |
| 203 | TIMBER SHUTTERING (FORMWORK).Centering and shuttering including strutting, propping etc. and removal of form work for: Foundations, footings, bases of columns, etc. for mass concrete. |
| 204 | Lintels,- beams, plinth beams, girders, bressumers and cantilevers. |
| 205 | Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 206 | MASONARY WORKS.Brick work with common burnt clay F.P.S.(non modular) bricks of class designation 7.5 infoundation and plinth in: Cement mortar 1:4( 1 cement: 4coarsesand). Half Brick masonary with common burnt clay F.P.S.( non modular) bricks of class designation 7.5 in Superstructure above plinth level up to floor level V. |
| 207 | Cement mortar 1:3(1 cement : 3 coarse sand) |
| 208 | PLASTERING WORKS. 15 mm cement plaster on the rough side of single or half brick wallof mix: 1:4(1 cement : 4 coarse sand). 12 mm cement plaster of mix: |
| 209 | 1:4(1 cement : 4 fine sand) |
| 210 | PAINTING.Providing and appying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.Finishing walls with premium Acrylic smooth exterior paint of required shade: |
| 211 | New work (Two or more coat applied1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 212 | REINFORCEMENT. Steel reinforcement for RCC work including staightening, cutting, bending , placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-S00D or more. |
| 213 | Electric resistance or induction butt welded tubes |
| 214 | Ceiling fan |
| 215 | LED Lights |
| 216 | Exhaust fan |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy