}

Tender For Drilling Of 500 Mm Dia Bore With Reverse Rotary Rig In All Kinds Of Soil Including The Cost Of Consumable Stores, Fuel Oil And Transportation Of Rig To The Site. Complete In All Respect. Drilling Of 500 Mm Dia Bore With Reverse Rotary Rig Upto, Hoshiarpur-Punjab

Water Supply And Sanitation Department-WSSD has published Tender For Drilling Of 500 Mm Dia Bore With Reverse Rotary Rig In All Kinds Of Soil Including The Cost Of Consumable Stores, Fuel Oil And Transportation Of Rig To The Site. Complete In All Respect. Drilling Of 500 Mm Dia Bore With Reverse Rotary Rig Upto. Submission Date for this Tender is 08-05-2024. Gaskets Tenders in Hoshiarpur Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

39990371
Corrigendum : Tender For Drilling Of 500 Mm Dia Bore With Reverse Rotary Rig In All Kinds Of Soil Including The Cost Of Consumable Stores, Fuel Oil And Transportation Of Rig To The Site. Complete In All Respect. Drilling Of 500 Mm Dia Bore With Reverse Rotary Rig Upto
Open Tender
Indian
Punjab
Hoshiarpur
08-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Tender For Drilling Of 500 Mm Dia Bore With Reverse Rotary Rig In All Kinds Of Soil Including The Cost Of Consumable Stores, Fuel Oil And Transportation Of Rig To The Site. Complete In All Respect. Drilling Of 500 Mm Dia Bore With Reverse Rotary Rig Upto 150 Mtr. Depth Bgl Drilling Of 500Mm Dia Bore With Reverse Rotatry Rig Beyond 150 M Depth Bgl Up To 300 Mtr Drilling Of Test Bore Hole Including The Rate For Logging ( Electric Logging Shall Be Carried Out By Contractor Upto Full Depth ) To Be Paid Only For The Drilling Depth Beyond The Bail Plug Margin Or The Tubewell Is Abandoned Making Electric Logging Of Borehole With Electronic Well Logger Including Cost Of Equipment At Site Etc.Complete In All Respect. Supplying, Lowering Of Ms Pipe As Per Is: 4270-2001 Including Ms Sockets Having Dimensions As Per Is Code Duly Welded With Ms Electrode To Have Extra Strength To Lower The Pipe Into Tubewell Bore. 200 Mm Nominal Diameter ( Weight 33.6 Kg Per Meter ) 6.40 Mm Thickness Supplying, Fixing & Lowering Of Stainless Steel Cage Type Wire Wound Screen As Per Is:8110-2000 Or Latest Isi Marked, Duly Welded With Suitable Grade S.S Welding Electrode To Lower The Strainer Into Tubewell Bore. ( Johnson Or Equivalent Make ) 200 Mm Steel Strainer ( Slot Size 0.75 Mm ) 6.30 Mm Thick Supplying, Fixing And Lowering Of Stainless Steel Socket As Per Is 8110-2000 Or Latest, Isi Marked Duly Welded With Suitable Grade Ss Welding Electrod To Lower The Strainer Into Tubewell Bore Complete In All Respect. 200 Mm Internal Diameter Supplying, Lowering And Fixing Of M.S. Special Socket To Connect Ss Strainer To M.S. Pipe Duly Welded With Suitable Grade Welding Electrode Complete In All Respect. 200 Mm Internal Diameter Supplying And Fixing Mild Steel Centering Guides Made Out Of 32Mm X 6Mm Thick M.S Bar Complete In All Respect. ( A ) Strainer & Ms Pipe Should Be Properly Jointed With Sockets And Duly Welded To Ensure Maximum Strength Of Joint. ( B ) A Steel Strip Of Suitable Size Should Be Welded Across The Length Of Strainer To Provide Additional Strength To The Tubewell Assembley. Supplying At Site Wooden Box Of Suitable Size With Lid & Locking Arrangment For Preserving Strata Sample Collected From The Bore. Collection Of Water Sample From Different Strata And Testing Of Sample From Approved Laboratory ( Physical & Chemical Analysis ) Supplying At Site Of Gravel Of 1 / 6 To 1 / 8 Sizes Including Pouring And Packing In The Annual Space Between The Pipe Assembly And The Bore. The Gravel Should Be Free From Dust, Dirt, Or The Vegetable Manner As Per Is 4097-1967 With Latest Amendments ( To Be Paid As Per Actual Length Of Pipe ) Supplying And Fixing M.S Well Cap Having Thread To Fix On Housing Pipe Complete In All Respect. 200 Mm Internal Diameter Supplying & Fixing Of M.S. Clamp Of Size 200Mm X 12Mm Made Out Of Ms Flat 1.52 M Long, Suitable To Fit The Housing Pipe Including The Cost Of Nut & Bolts Of Suitable Size Complete In All Respect. Development Of Stabillizing Of The Tubewell With Air Compressor Of Required Capacity As Directed By The Engineer-In-Charge Including Cost Of Tools, Appliances & Consumable To The Satisfaction Of Engineer-In-Charge. Capacity Of Air Compressor 300 Cfm At 250Psi Development Of Stabillizing Of The Tubewell With Submersible Pump Of Required Capacity As Directed By The Engineer-In-Charge Including Cost Of Tools, Appliances & Consumable To The Satisfaction Of Engineer-In-Charge. Testing Of Water Sample For Heavy Metal From Approved Laboratory ( Toxic Material Such As Arsenic, Lead, Mercury, Pesticide Etc. ) Provision For Clay Seal 3 Mtr ( As Per Bis Code Is 2800:2019 ) Thick For T / Well Complete In All Repect Supplying And Fixing Of Bail Plug Of M.S. Pipe Complete With Inverted U-Hook Attached To The Bottom Plug Complete In All Respects. Make Provision For Sterilisation Of Tubewell ( As Per Bis Code 2800:2019 ) Complete In All Respect Providing, Laying, Fixing & Jointing Of P.V.C. Pipes 10 Kg / Cm2 Isi Marked As Per Isi-4985 ( Isi Marked With The Prior Approval Of Engineer-In-Charge ) Casting Along The Trenches And Laying The Same In Trenhes To Correct Alignment And Gradients, Cutting, Jointing And Testing Complete As Per Specifications Including Special And Excavation 110 Mm O / D Pvc Pipe Providing & Fixing C.I / D.I Flanged End, Stem Of Ss ( Ais 1410 ) And Bronze ( Gunmetal ) Working Parts Sluice Valves Isi Marked 14846-2000, Including Jointing, Testing & Cost Of Nuts, Bolts & Insertion Sheet, All Carriage Complete ( With The Approval Of Engineer - In – Charge ) 100 Mm I / D Construction Of Masonry Sluice Valve Chamber Excluding Sluice Valve Cover As Per Standard Design & Drawings Of Public Health Department Size 0.9M X 0.9M ) Providing , Laying, Jointing, Fixing And Testing Of 110 Mm O / D Pvc Pipe With Existing 100 Mm I / D C.I Rising Main With I No C.I A / F Tee 4X4X4 And Nut Bolt Complete All Respect ( For Making Connection With Existing 100 Mm I / D C.I Rising Main And Bye -Pass ) Providing And Fixing G.I. Column Pipe Of Is 1239-2004 Medium Class Size 50 Mm ( In 3Mtr Lengths Each With Flanges, Screwed And Welded On Both Sides ) Rubber Gaskets, Nuts And Bolts Complete In All Respects. Providing And Fixing Submersible Cable ( Finolex / Havell Or Equivalent Make ) With Copper Conductor Pvc Insulated Of 4.00 Mm2 Size As Per Is 694-1990 Reaffirmed 2000 Complete In All Respects C.I Fitting Inside Pump Chamber Providing And Installing 100Mm Dia Delivery Main ( From Tube Well To Duck Foot Bend Including Cost Of C.I / D.F Pipes, D / F Sluice Valves, D / F Nrv & Specials As C.I Bends, Tail Piece Tees Etc.. Inside The Pump Chamber As Per Standard Design Complete In All Respects. ( Electro Steel Casting / Kesoram Pipe Or Equivalent Make ) Less Credit Of Old Material Delivery Main Size 100 Mm Gi Pipe 50 Mm ( 24 Mtr ) Cable 4 Mm2

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 10-Oct-2023 fgdg Date 18-10-2023
2 19-Oct-2023 dgdggd Date 30-10-2023
3 31-Oct-2023 ryryyr Date 06-11-2023
4 07-Nov-2023 gddgg Date 21-11-2023
5 22-Nov-2023 gdg Date 05-12-2023
6 06-Dec-2023 dggdfgg Date 18-12-2023
7 19-Dec-2023 hgjj Date 02-01-2024
8 03-Jan-2024 jgjhj Date 22-01-2024
9 23-Jan-2024 date extension Date 12-02-2024
10 13-Feb-2024 xxx Date 19-02-2024
11 20-Feb-2024 gdgdgdgdg Date 28-02-2024
12 29-Feb-2024 fhhfhh Date 07-03-2024
13 08-Mar-2024 date extended Date 11-03-2024
14 12-Mar-2024 date extendd Date 19-03-2024
15 20-Mar-2024 fegete Date 09-04-2024
16 10-Apr-2024 dateextended Date 23-04-2024
17 24-Apr-2024 handowaldate Date 08-05-2024

Key Value

Document Fees
INR 1000 /-
EMD
INR 20880.0 /-
Tender Value
INR 10.43 Lakhs /-

Attachment

FileName File Description File Size
0e7f5e43-c8f2-4532-aa1a-dd00ba137575.html Tender Notice 45.7 KB
PrsheetHandowal.xls Tender Document 69.5 KB
Tendernotice_1.pdf Tender Document 664.3 KB
Tendernotice_2.pdf Tender Document 2.21 MB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail