Tender For Construction Of New 50 Beded Boys Hostel With Various Work At Bicchiwara District Dungarpur, dungarpur-Rajasthan

Office of the Director Swach Project has published Tender For Construction Of New 50 Beded Boys Hostel With Various Work At Bicchiwara District Dungarpur. Submission Date for this Tender is 04-10-2023. Building Work Tenders in dungarpur Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

39971288
Tender For Construction Of New 50 Beded Boys Hostel With Various Work At Bicchiwara District Dungarpur
Open Tender
Indian
Rajasthan
dungarpur
04-10-2023

Tender Details

Construction Of New 50 Beded Boys Hostel With Various Work At Bicchiwara District Dungarpur

Key Value

Document Fees
INR 2000 /-
EMD
INR 551000.0 /-
Tender Value
INR 2.75 Crore /-

BOQ Items

Name of Work: Construction of 50 Bedded New Boys Hostel at Bichhiwara, Distt.- Dungarpur
Sl. No. Item Description
1Clearingjungleincludinguprootingofrank vegetation, grass, brush wood, trees and saplingsofgirthupto30cmmeasuredata height of 1 m above ground level and removalof rubbish
2uptoadistance of50m outside the periphery of the area cleared.
3Surface dressing of the ground including removing vegetation and inequalities not exceeding 15cm deep and disposal of rubbish lead up to 50 Mtr. And lift up to 1.5 Mtr.
4Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means infoundationtrenchesordrains(not exceeding 1.5 m in width or 10 sum on plan) includingdressingofsidesandrammingof bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils
5Excavationworkbymechanicalmeans (Hydraulic excavator) / manual means in foundation trenches ordrains not exceeding 1.5minwidthor10sqmonplanincluding dressing of sides and ramming of bottoms lift upto1.5m,includinggettingoutthe excavatedsoilanddisposalofsurplus excavated soil as directed with a lead in a 50 meter including stacking of useful material if available : Ordinary rock
6Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30cm in depth. 1.5m in widthaswellas10sqmonplan)including disposalofexcavatedearth,leadupto50m andliftupto1.5m,disposedearthtobe levelled and neatly dressed : All kinds of soil
7Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30cm in depth. 1.5m in widthaswellas10sqmonplan)including disposalofexcavatedearth,leadupto50m andliftupto1.5m,disposedearthtobe levelled and neatly dressed : Ordinary rock
8Providing and laying in position cement concreteincludingcuring,compactionetc. complete in specified grade excludingthe cost of centering and shuttering - All workup toplinthlevel.1:4:8(1cement:4coarse sand : 8 graded stoneaggregate 40 mm nominal size).
9Fillingavailableexcavatedearth(excluding rock)intrenchesplinthsideoffoundation etc.inlayersnotexceeding20cmindepth consolidation each deposited layer by rammingandwateringincludingleadupto 50 mtr and with all lift.
10Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level includingcuring,compaction,finishingwith rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excludingthecostofcentering,shuttering and reinforcement. M25 grade Design Mix
11CenteringandShutteringwithplywoodor steel sheets including strutting, propping bracing both ways and removal of formwork forfoundation, footings, strap beam,raft , bases of columns etc.
12Supplyingchemicalemulsioninsealed containers including delivery as specified. Chlorpyriphos/Lindane emulsifiable concentrate of 20%
13Diluting and injection Chloropyrifos Emulsifiableconcentrate20%with1% concentration for PRE-CONSTRUCTIONAL Anti termite treatment as per IS 6313 part III as amended from time to time and creating a continuouschemicalbarrierunderand aroundthecolumnpits,walltrenches, basementexcavation,topsurfaceofplinth filling,junctionofwallandflooralongthe external perimeter of building expansion joints,overthetopsurfaceofconsolidated earthofwhichaprochistobelaid surroundingofpipesandconduitsetc. completeasper specification(Plinthfloor area only shall be measured for payment and excluding the cost of chemical emulsion).
14Random Rubble stone masonry for with hard stoneinfoundationandplinthinCement Sand mortar above 30 CM thick wall in: Cement Mortar 1:4 ( 1-Cement : 4-Sand).
15Random Rubble stone masonry for with hard stoneinfoundationandplinthinCement Sand mortar above 30 CM thick wall in: Cement Mortar 1:6 ( 1-Cement : 6-Sand).
16Random rubble dry stone Kharanja under floor.
17Providing and laying in position specified grade ofcement concrete for RCC structural elements uptofloorfivelevel including curing,compaction,finishingwithrendering incementsandmortar 1:3 (1 cement: 3 coarse sand) and making good the joints and costofplastizers (ifrequired )excluding the cost of centering, shuttering and reinforcement forWalls(anythickness) including attached pilasters, buttresses, plinth andstringcourses,fillets,columns,pillars, piers, abutments, posts and struts etc. M25 grade Design Mix
18Centering & shuttering with plywood or steel sheetsincludingstrutting,proppingbracing bothwayswithsteelprops andremovalof formwork for upto floor five level for : Columns, pillars, posts and struts etc.
19Providing and laying in position specified grade ofcement concrete for RCC structural elements uptofloorfivelevel including curing,compaction,finishingwithrendering incementsandmortar 1:3 (1 cement: 3 coarse sand) and making good the joints and costofplastizers(ifrequired)excludingthe cost of centering, shuttering and reinforcementforBeams, suspended floors, roofs, griders having slopes up to 15º, landings,balconies,shelves,chajjas,lintels, bands, plain windows sills, staircases and spiral staircases etc. M25 grade Design Mix
20Centering & shuttering with plywood or steel sheetsincludingstrutting,proppingbracing bothwayswithsteelprops andremovalof formwork for upto floor five level for : Suspended floors, roofs, landings, staircases, balconies,girders, cantilevers,bands, coping bedplates, anchor blocks, sills, chhajjas, lintel,beam, plinth beam etc.
21Providingandfabricatingreinforcementfor R.C.C.workincludingstraightening,cutting, bending, placing in position and binding (includingcostofbindingwire)allcomplete up to floor three level. Thermo-mechanically Treated bars (Conforming of relevent IS code)
22BrickworkwithF.P.S.bricksofclass designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in : Cementmortar1:6(1cement:6coarse sand)
23Brick masonry with F.P.S. bricks of class designation 75 in foundation and plinth with bricks Cementmortar1:6(1cement:6coarse sand)
24HalfbrickmasonryinSuperstructure, above plinth level upto floor Vlevelusing bricks of designation 75Cement mortar 1 : 4 (1 cement : 4 coarse sand)
25Add extra providingand placing in position 2 Nos.6mm Ø M.S. barat every thirdcourse of half brick masonry.
26Providing and fixing T-iron frames for doors, windowsandventilatorsofmildsteelTee- sections, joints mitred and welded with 15x3 mmlugs10cmlongembeddedincement concreteblocks15x10x10 cm of 1:3:6 (1 cement:3coarsesand:6gradedstone aggregate 20 mm nominal size) or with woodenplugsandscrewsorrawlplugs and screwsorwithfixingclipsorwithboltsand nutsasrequireincludingfixingofnecessary butt hinges and screws and applying a priming coat of approved steel primer.
27Providing and fixing steel glazed window frame made out of80x40mmhollow sheet sectionof16gaugethickness,jointmitred weldedandgrindedincludingholdfastof steellugs13mmx3mmand15Cmlong embeddedinCCblock15x10x10Cmof 1:3:6nominalconcreteandincludingfixing of pivoted hinges of superior quality, window shuttersmadeoutof50x25.0mmhollow steelsection15 mm paitam of18gauge thickness,joint mitred andgrinded including 10mm x 10mm square bars welded to frame for paitam fixing float glass 4mm thick panes withglazingclipsandmetalsashputtyand fixingofshuttersframespegstay,Ushape handle100mmlong,towerbolts100mm long of steel powder coated superior quality including fixingand jointingwith frame hingesprimingcoatwithsteelprimer completeinallrespectasperdirectionof Engineer-in –charge
28Window openable
29Window fixed
30Supplyingandfixingfixedwiregaugeof14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance.
31Providing and fixing Square bars or other flat welded to window, ventilatiors etc.
3210mm Bar 0.78 Kg/Rmt.
33Providingandfixinginpositioncollapsible steel shutters with vertical M.S. Channels 20 x 10 x 2mm and bracket with flat iron diagonals 20 x 5mm. size with top and bottomrailofT-iron40x40x6mm.with 40mm dia steel pulleys/ball bearing complete withbolts,nutslockingarrangementsinside andoutsidestoppers,handlesetc. asper specification including applying a priming coatof approvedsteel primer.(Tobe measured and paid as per outer dimension).
34ProvidingandfixingM.S.sheet1mmthick dabble leaf doorshutterin angleiron frame 35x35x5mm suitabilly diagonally braced with 25x3mmflatiron aboveand belowlockrail ofsize50x5mmbeadingextraincludingall fittings, as per direction of Engg. incharge but excludingcostofchowkhats:includingtwo coats of anit-corrosive red oxide primer paint
35Providing and fixing of double leaf steel shutter for cupboard, the Sqm frame is made of pressed steel ISI section 80x25mmx 1.25 mmthickwith1.00mmMSsheettospot weldedincludingholdfastsof15x3mm,MS oxidizedfittingssuchasbutthinges,sliding doorsbolts,handles,towerboltsandtwin pegetccompleteincludingapplying priming coatofapprovedsteelprimerofredoxide zinc chromate and spray painting in approved shade with deco paint of approved quality complete as per direction of Engineer In Charge
36Providing and fixing stainless steel railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing andmakingcurvature(whereverrequired) and fitting the same with necessary stainless steelnutsandboltscomplete,i/cfixingthe railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waistslab withsuitable arrangement asperapprovalofEngineer-in-charge,(for paymentpurpose only weight ofstainless steel members shall be considered excluding fixingaccessoriessuchasnuts,bolts, fasteners etc.). Grade 304
37Providing& fixing door, window, chowkhats andotherframes,includingantitermite treatment,M.S. flat, hold fasts of size250x 40 x3mm fixedwithM.S.bolt5mmdia 50mmlongdulyembeddedincement concrete M-15 grade : Sal wood Grade - I.
38Providing and fixing fully panelled/partly panelled/double leaf shutter frame for doorsasperapproveddesignanddrawings withapprovedordinaryC.P./oxidisedsteel fittingsasperAnnexure-"A"andwidthof styles&toprailsof100mmandlockrails width of 150mm and bottom rails of 200mm widthincludingteakwoodbeadingofsize 19mm x 12mm on both faces complete : 35 mm thick Nigeria wood grade I
39Providingandfixingwoodpanellingor panelling and glazing in panelled or panelled andglazedshuttersfordoors,windowsand clerestory windows (Area of opening for panel inserts excluding portion inside grooves orrebatesto bemeasured).Panellingfor panelled and glazed shutter 25 mm to 40 mm thick
40IS710-1976marked12mmthickteakply BWR both side
41Wiregauge24gauge14meshofIS1568- 1970 marked 85 gauge of dia 0.56 mm
426 mm float glass
43Extraforprovidingothertypeoffittingsas mention in annexure A ( as approved by EI) : Brass fittings
44Providing and fixing curtain rods of 1.25 mm thickchromiumplated brass plate, with two chromiumplatedbrassbracketsfixedwith C.P.brassscrewsandwoodenplugs,etc., wherever necessary complete:
4520 mm
46Providing and fixing external grade board solidcoresingleleafflushdoorshuttersISI 2202-67 marked using Phenol formal dehyderesinin glue both sides with approved steel fittings complete as per annexure"A" : 35 mm thick.Commercial Veneer both side
47Extraforprovidingexternal lippingwith 2nd classteak wood battens6 mm minimum depth on alledges ofshutters (overall area ofdoorshuttertobemeasured)Overitem no. 8.13.
48Steelworkinbuiltuptubulartrusses includingcutting,hoisting(heightupto10 m)fixinginpositionandapplyingapriming coatofapprovedsteelprimer,weldedand boltedincludingspecial shapedwashers etc. complete. Hot finished welded type tubes.
49ProvidingcorrugatedG.S.sheetroofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mmdiameterwithbitumenandG.I.limpet washersor withG.I.limpetwashersfilled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/ verticalor curvedsurfaces)excludingthe cost of purlins, rafters and trusses and including cutting to size and shape whenever required. 0.63 mm thick with zinc coating not less than 275 gm/m2
50Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing upto any pitch including fixing with polymer coated „J? or „L?hooks, bolts& nuts8mm dia.G.I plain/bitumenwasherscompletebut excluding the costof purlins,rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum0.3% Ultra-voilet stabiliserin resin systemunderapproximately2400psiand hotcured.Theyshallbeofuniform pigmentationandthicknesswithoutair pockets and shall confoim to IS 10192 and IS 12866.Thesheetsshallbeopaqueor translucent,clearorpigmented,texturedor smooth as specified.
51Providing gola 75x75 mm in cement concrete 1:2:4(1cement:2 coarsesand:4stone aggregate 10mmand down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :
52Supplyingandapplyingbituminoussolution primeronroofsoronwallsurfaceat0.24 litre per sqm.
53Providing and laying brick kharanjaon roofs with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2% integral water proofing compoundinsquarepattern75mmto 100mm thick average
54Providing&layingbrokenglazedtitleson roof(brokenglazedtiles notlessthan9 Kg/Sqm) on top of hot bitumen @ 1.7 Kg/Sqm.(1.40Kgof VG-40(30/40)grade and 0.30 Kg/Sqm. OfVG-10 (80/100) grade) andjointsfilledwithcementmortar1:2(1 cement:2 marble dust mixed with water proofingcompundallcompleteasper direction of Engineer-in-charge.
55Providingandlayingwaterproofing treatmentinsunkenportionofWCs, bathroom etc., by applying cementslurry mixedwithwaterproofingcement compound consisting of applying : a)firstlayerofslurryofcement@0.488 kg/sqmmixedwithwaterproffingcement compound@0.253kg//sqm.Thislayerwill be allowed to air cure for 4 hours. b) Second layerofslurry ofcement@0.242kg/sqm mixed with water proffing cement compound @ 0.126 kg/sqm This layer will be allowed to air cure for4 hours followed by water curing for 48 hours. The rates includes preparation of surface treatment&sealingofalljoints,corners, junction with polymer mixed slurry.
56Fillingofsunkportionofroofwithearthen pots of required height including filling voids with1:3:6lightconcrete,usingbrickbats completelevellinganddressingthesurface by 50mm thick cement concrete 1:2:4 as per specification.
57Kota stone slab flooring 25 mm thick over 20 mm (average) thickbase laid over and jointedwithgreycementslurrymixedwith pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4coarsesand)Forareaofeachslabfrom 2001 to 5000 Sq.Cm
58Kotastoneslabs25mmthickinrisersof steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs,including rubbingand polishing complete
59Supplying and fixing in walls machine cut and polished stone shelves, tands andin CM 1:3 with machine cut edges : Sand or other approved stone 50mm thick.
60Supplying and fixing in walls machine cut and polished stone shelves, tands andin CM 1:3 withmachinecutedges:Kotastone25to 30mm thick.
61Extraoveritemformachinecutbothside polished stone is used.
62Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars,steps,Shelves,SillsCounters,Floors etc. 15-18 mm thick laid on 12mm (Av.) thick baseofcementmortar1:3(1cement:3 coarse sand) jointing with white cement mortar1:2(1white cement:2marble dust) with pigment to match theshade ofthe marbleslabincludinggrinding,rubbingand polishing complete. South (Red) Above 3601 Cm2 Slabs
63ProvidingandfixingMarblestoneflooring tablerubbed,15-18mmthickover20mm (Av.)thickbaseofCM1:4(1cement:4 coarse sand) jointing with white cement mortar 1:2 (1 white cement : 2 marble dust) with pigment to match theshade ofthe marbleslabincludinggrinding,rubbingand polishing complete. OR Providing and fixing stone slabs table rubbed, 15-18 mm thick in Walls, Steps, Pillars, Counters, Jambs, Shelves, Sills etc. laid on 12mm (Av.) thick base of CM 1:3 (1 cement:3coarsesand)jointingwithwhite cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shadeofthemarbleslabincludinggrinding, rubbing and polishing complete. Rajnagar 1st quality/Ageria with light spots. Above 3601 Cm2 Slabs
64Extra for providing edgemoulding to 15- 18mmthick marble/ Granite/Kota stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer in-Charge.
65Marble work Half Edge moulding
66Granite/KotaStone WorkHalfEdge moulding
67Providingnonslipgroovestogranite/kota stoneflooring,counters,vanitiesetc.using groove cutter V type including machine polishingtogroovetogivehighglossfinish etc. complete as per design approvedby engineer in charge
68Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacture ) of approved make in all colours, shades except burgundy,bottlegreen,blackofanysizeas approvedbyEngineerinchargeinskiriting, risersofstepsanddadosover12mmthick bedofcementmortar1:3(1cement:3 coarsesand)andjointingwithgreycement slurry @ 3.3 kg per sqm including pointing in white mixed with pigment of matching shade complete.
69Providing and laying Ceramic MATfloor tiles (thicknesstobespecifiedbythe manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White,Ivory,Grey,FumeRed Brownof any size,laidon20mmthick bedofcement mortar 1:4 (1 cement : 4 coarse sand) includingpointinginwhitecement mixed with pigment of matching shade complete.
70P&F 1stqualityVitrifiedPorcelain Polished tilesonfloor,skirtingandstepsetc.in differentsizes(thicknesstobespecifiedby manufactuer) with water absortion less than 0.08%andconformingtoIS15622of approved make in all colour and shade,laid with 20 mm thick CM 1 : 4 including grountingthejointswithwhitecementand matchingpigmentetccomplete.size600 mm X 600 mm
71Rough Chisel dressed Kota stone 35 mm thick flooringofapprovedshadesetinpattern over 20mm thick base of cement mortar 1:6 (1 cement : 6 coarse sand) and pointingwith cementsandmortar 1:3 withpigmentto match the shade of stone with joint thickness up to 15 mm complete in all respects :
72Chequerred precast cement concrete tiles 22 mmthickinfootpath&courtyardjointed with neat cement slurry mixed with pigment to match the shade of tiles includingrubbing andcleaningetc.completeon20mmthick bedofcementmortar1:4(1cement:4 coarse sand) Dark shade using ordinary cement.
73Plasteronnewsurfaceonwallincement sand mortar 1:4 including raking of joints etc. complete fine finish: 20mm thick
74Plasteronnewsurfaceonwallincement sand mortar 1:4 including raking of joints etc. complete fine finish: 25mm thick
756 mm cement plaster to ceiling of mix 1:3(1 cement : 3 fine sand)
76Extra for lining out plaster to imitate stone or concrete blocks walling
77MakingofDripcourse(Tapaka)incement sandmortar1:6widthupto40mmand10 mm thick as per approved design
78Making grooves as per design in plaster 10mm to 20mm wide
79Providingandapplyingwhitecementbased puttyoverplasteredsurfacetopreparethe surface even and smooth complete. New Plastered Surface (three or more coats)
80Distemperingwithoilboundwashable distemper ofapprovedbrandand manufacture to give an even shade including all scaffolding: New work (two or more coats) over and including scrapping and priming coat with cement primer.
81PaintingexteriorsurfaceofWallwith100% acrylicexterior paint of approved brand and manufacture to give an even shade with two ormorecoatsincludingprepartionofbase withsandpapering,primer,putty,etc completeinallrespectincludingscaffolding and safety provision New Work
82Finishing walls with textured exterior paint of required shade as perapproved colour complete as per manufacturers specifications includingprimer coatand protectingcoat including scaffolding and safety provision
83Painting with syntheticenamel paint of approved brand and manufacture togive an evenshade:Twoormorecoatsonnew work
84French sprit polishing: Two or more coats on new workincluding a coat of wood filler.
85Providing and Fixing Chiken wire mesh at the joint of masonrymembers/ R.C.C. Members with Nails complete in all respect.
86Renewingglasspanes,withputtyandnails wherevernecessary: Floatglasspanesof thickness 4 mm
87RebarringworkinoldR.C.Cstructures including making bore hole to adjust required bardiameterandfillingagoodqualityfiller to provide a tensil strength as per requirementandfixtheBartothesaction including cost of bars.
8812 mm bar
8916 mm bar
9020 mm bar
91Providing and laying damp-proof course with cementconcretegradeM-150(1:2:4) mortarprepared with1% solutionof water- proofcompoundcomplete asper specification . 50mm thick.
92ProvidingandfixingIS:3564marked Aluminiumdiecastbodytubulartype universalhydraulicdoorcloserwith necessary accessories and screws etc. complete.
93Providing and laying of paverblock as per IS 15658:2006(Indianstandardforprecast concreteblockforpavingspecification)and IRC:SP:63-2004(guidelinesfortheuseof interlocking concrete block pavement) M-35,60mmthicktobeusedinlighttraffic (Light traffic is defined as a daily traffic up to 150commercialvehiclesexceeding30KN ladenweight, or an equivalentup to 0.5 million standard axles (MSA) for a design life of20years(Astandardaxleisdefinedasa singleaxleloadof81.6KN)likepedestrian plazas, shopping complexes ramps, car parks, officedriveways ,housing colonies,office complexes, rural roads with low volume traffic, farm houses , beach sites, tourist resorts,localauthorityfootways,residential roads,etc.Category„B?Denatedonlytwo side like I,Z,T shape etc. as per IRC SP 63:2004
94P & F Indian type white glazed vitreous china 1st quality W.C. orissa pan (IS :2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor:
95Size 580x440 mm
96P & F European type white glazed vitreous china 1st quality W.C pan (IS : 2556 Mark) with P or S trap including cutting and making good the wall and floor
97P & F water closet Seat Covers with brass hinges complete : Solid PVC (IS 2548 marked) grade-I White for EWC.
98P & F W.V.C. Half-Round Channel of approved make in C.M. 1:3, joints finished in white cement of: Size 150mm dia.
99P & F Low level Flushing Cistern of 10 litres capacity (IS : 2556 mark) of approved make with complete fittings C.I. brackets duly painted, brass ball cock with ball (IS: 1703 mark) complete including cutting and making good the wall: PVC with PVC bend as per IS : 7231.
100P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make, P.V.C Waste pipe with PVC nut 32 mm complete including cutting & making good the wall : Size 550 mm x 400 mm dia for counter top
101KITCHEN & LAB. SINKS: P & F Kitchen & Lab. Sink of approved make with C.I. brackets duly painted, 40 mm C.P. waste coupling, C.P. Brass chain with rubber plug, 40 mm G.I. waste pipe up-to floor level complete including cutting and making good the wall & floor : 1.0 mm thick stainless steel AISI -304 & IS 13983-1994 kitchen sink of approved make as per Engineer-in-charge with large waste coupling. Overall size (inches) = 24 x 18 x 8, Bowl size(inches) = 20x16x8
102P & F Bevelled edge Mirror/mirror with teak wood lipping around of special glass of approved make as per direction of Engineer-in-charge complete with 6mm thick commercial ply base fixed to wooden screws & washers. Size 600 x 450mm x 4 mm thick
103P & F Toilet Shelf of approved quality/ make:
104Hard Plastic of approved make as per direction of EI of size 590x140mm
105P & F Towel Rail or Ring of approved quality/make:
106C.P. brass towel rail with brackets 600 x 20mm.
107P & F Grating of approved quality/make: Stainless Steel Sheet size 125mm dia.
108P & F Tooth Paste & Brush Holder of approved quality/make:
109C.P. brass (Heavy and Superior quality)
110P & F Soap Dish or Tray of approved quality/ make
111C.P. brass heavy and superior quality.
112P & F Shower arm 15mm dia of approved quality/make.
113C.P.brass heavy & superior quality 150mm Projection.
114P & F Bath Shower of approved quality/ make.
115C.P. brass of Heavy & superior quality, revolving with adjustable key 150mm.
116P & F Jet spray for water closet with C.P. Copper Tube flange of approved make.
117P & F G.I. Pipes (External Work) with G.I. fittings excluding union (IS : 1239 Mark) including trenching & refilling earth etc.
11825 mm dia nominal bore B class
11932 mm dia nominal bore B class
12040 mm dia nominal bore B class
121Making connection of G.I. distribution branch with G.I. main including all fitting.
122Upto 25mm dia
123Beyond 25mm & upto 100mm dia
124P & F Pilllar Cocks (IS :8931 : 1993 Mark) of superior quality and approved make:
125C.P. Pillar cock, 15 mm dia nominal bore
126P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make:
127C.P. Brass bib cock,15mm nominal bore.
128(-do-) Long body, 15mm nominal bore weight not less than 690 gm
129(-do-) Elbow-action, 15mm nominal bore.
130P & F Stop Cock (IS :8931 Mark), superior quality & of approved make:
131C.P. Brass 15mm nominal bore.
132C.P. Brass Concealed Stop Cock 15mm.
133P & F ball cock (IS: 1703 Mark) with rod & pvc ball complete make 750 gm 15mm nominal size
134P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc. C.P. Inlet connection 15mm.Brass (IS : 8931 marked) with 37 cm long pipe and nut.
135P & F 15 mm. Dia Connection Pipe of approved quality/make : PVC pipe with C.P. Brass nuts upto length, 450mm
136P & F Flush Cock / Flush Valve (IS : 9758 Mark) for WC of approved quality make : CP brass Concealed 25mm nominal bore.
137P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make :
138Gun-metal 15mm nominal bore.
139Gun-metal 20mm nominal bore.
140Gun-metal 25mm nominal bore.
141Gun-metal 40mm nominal bore.
142Gun-metal 50mm nominal bore.
143P & F PVC Storage Tank ISI Marked (IS : 12701) indicating the BIS license No), of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design:
144750 litres capacity.
1451000 litres capacity.
146Hoisting Charges for each floor :
147For 750 Liters capacity
148For 1000 Liters capacity
149Supply & fixing G.I. Union ISI marked in G.I. pipe line as required complete in all respect of size :
15015mm dia nominal bore
15125mm dia nominal bore
15240mm dia nominal bore
15350mm dia nominal bore
154Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1 metre spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work Exposed on wall)
15515mm dia nominal size
15620mm dia nominal size
15725mm dia nominal size
15840mm dia nominal size
15950mm dia nominal size
160Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.,)
16115 mm dia nominal bore B class
16220mm dia
16325 mm dia nominal bore B class
164Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, this included jointing of pipes & fittings with one step CPVC solvent cement , trenching refilling & testing of joints complete as per direction of Engineer in Charge. (External work).
16515 mm dia nominal bore B class
16620 mm dia nominal bore B class
16725 mm dia nominal bore B class
16840 mm dia nominal bore B class
16950 mm dia nominal bore B class
170Providing & Laying C.C. 1:3:6 (Stone Agreegate 20mm nominal size) all around PVC Pipe including 7.5 cm thick bed concerte [Width & Height = Dia of Pipe in CM+15CM] excluding cost of Pipe & Excavation of trenches etc.
171PVC pipe 160 mm dia
172Providing, Laying & Jointing R.C.C. class NP-2 Non-Pressure pipes (IS : 458mark) of approved make with collars, jointed with C.M. 1:2 or having Spigot and socket ends with flexible rubber rings joint including testing of joints etc. complete :
173300mm dia Internal
174P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2 .) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant.
17575 mm dia
176110 mm dia
177160 mm dia
178P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant:
179Coppler
18075 mm
181110 mm dia
182160 mm dia
183Plain Tee
18475 mm
185110 mm dia
186Door Tee
18775 mm
188110 mm dia
189Door Y
19075 mm
191110 mm dia
192Bend 87.5
19375 mm
194110 mm dia
195160 mm dia
196Vent Cowel
197110 mm dia
198Pipe Clip
19975 mm
200110 mm dia
201Plain Floor Trap
202110 mm dia
203Gully trap
204110 mm dia
205Construction of manhole in all type of soil inner size 90 X 60 Cm. 300 mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5 10 in foundation, 20 mm thick inside plaster in CM 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring, making channels, 80mm thick stone slab covering with 40mm thick M-15 grade C.C. flooring, Cement cover with frame of 450mm dia, earthwork etc. complete as per design including disposal of surplus earth within 50 mtr. lead. Depth up to 0.5 M
206Construction of chamber in all type of soil with 300 mm thick masonry in CM 1:6 m,10 cm thick C.C. 1:5:10 in foundation, 20mm thick insider plaster in Cm 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring , earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr.
207Inside size 450 X 450 mm depth upto 0.5 M Cement cover with frame.
208Construction of soakage well in all type of soil with 300 mm thick dry masonry, top and bottom 300 mm course in CM 1:6, 80mm thick stone slab, jointing of slab in CM 1 : 3, Ralthal, Kharanja, 40 mm thick M-15 grade C.C flooring , earthwork complete as per approved drawing including disposal of earth within a lead of 50 mtr.: Size 240 Cm. dia outside & 240 Cm. depth.
209Construction of septic Tank in all types of soil with 40 Cm .thick masonry in CM 1:6, 15 Cm thick C.C bed of 1:5:10, M- 15 grade C.C floor & RCC slab covering with M15 grade c.c. floor, 50 mm thick stone slab partition walls, 20 mm thick plaster in CM 1:6 finished with neat floating cement, 4 Nos stone foot rests of approved design ,two No. 450 mm dia each Ferro cement cover with frame, earth work etc. complete as per approved drawing including disposal of surplus earth within a lead of 50 mtr:-
210Size 200x100x130 cm.(for 10 users) with 115 mm thick RCC (M-20) slab with Tor steel reinforcement 8mm ? @15 cm c/c bothways including shuttering complete in all respect.
211Add extra if R.C.C slab of designed thickness & reinforcement is provided on manhole in place of stone slab( Actual area of R.C.C slab to be measured).
212Finishing with neat cementpunning) on wall tiles
213Providing and laying in position specified grade ofcement concrete for RCC structural elements uptofloorfivelevel including curing,compaction,finishingwithrendering incementsandmortar 1:3 (1 cement: 3 coarse sand) and making good the joints and costofplastizers(ifrequired)excludingthe cost of centering, shuttering and reinforcementforBeams, suspended floors, roofs, griders having slopes up to 15º, landings,balconies,shelves,chajjas,lintels, bands, plain windows sills, staircases and spiral staircases etc. M20 grade Design Mix
214Construction Of Tube Well upto 100mtr depth and above in all type of rocks by DTH system and over burden to accommodate casing pipe of followinf sizes in all types of soil and over burdens including lowering of casing pipes but excluding cost of casing pipes as per IS:2800(Part I & II) 1979specifications the work would be completed after obtaining sand free water. the tube well should have throughout bore as pere nominal dia. of casing pipe (site to be verified by approved geologist): 150mm Dia nominal bore.
215Supply of ERW M.S. black casing pipe ISI marked (IS:4270/1992) of grade Fe410 of following sizes at site of work. 150 mm Nominal bore of pipe
216S & F tube well cover of M.S. Sheet (6mm thick) with nuts and bolts complete for casing size 150 mm dia
217S & F M.S. clamp set of 50x 6 mm flat iron with nuts and bolts etc. for holding the riser pipe assembly of submersible pump set.
218Providing & Fixing of HDPE pipe ISI mark (IS:4984/95) for water supply (suitable for submersible & jet pump) with required fittings
219for vertical installation 63 mm OD 6 kg / cm2
220Horizantal installation 63mm OD 4kg/cm2
221SITC of Radial / mixed flow ISI marked water and anti-corrosive liquid filled submersible motor pump sets suitable for 100/150mm dia borewell. The size of adopter fixed on top of the motor should exceed the top of coupler , for safegaurd the coupler. The construction material of motor and pump should match IS: 8034 : 2018 and IS: 9283 guideline. The radial flow pumpset should operate at 5 star energy efficiency level of BEE and mixed flow pump set should operate at 3 star energy level of BEE, accompained by valid BEE certificate. Motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008, & IS12615:2011 with required accessories including making connection suitable for Bore well. The job includes labour part of lowering of riser pipe G.I./ H.D.P.E. with rope, cables & pump, installation of complete fitting and accessories, jointing of electrical cables up to Starter. All labour for testing of submersible pumps set and supply of water to water mains, complete in all respect. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
222100 mm diameter Submersible pump shall have following HP Rating, phase, Head range, Discharge range respectively.
2233.0 HP, 1-Ø, (40 -170)Mtr, (60- 20) LPM Copper Wound
224SITC of Contactor OEM Fabricated DOL/Star-Delta Starter panel with switchgear selection as per Type-2 Cordinatiom Chart and made out from 1.6 mm thick powder coated CRCA sheet, enclosure comprising of over load protection relay, short circuit & single phasing protection, Illuminated ON / OFF push buttons, ammeter, voltmeter, indicating lamps etc. suitable for following rating motors complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . For Three phase Submersible / Mono block pump 3.0 HP to 5.0 HP ( DOL starter )
225Providing & Laying of Polypropylene rope Confirming to IS:5175 for submersible pump of following sizes. complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 20mm (suitable for 90 mm OD pipe)
226P/Laying ISI marked P.V.C. insulated submersible cable confirming to(IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, existing pipe / open trench / Cable tray / on surface including making connection etc. as required. For additional technical parameters of product / work refer Annexure "A" attached with this BSR 10.0 Sq.mm 3 core flat / Round
227Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it"sISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheet"s & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure "A" attached with this BSR
228Short point (up to 3 mtr.)
229Medium point (up to 6 mtr.)
230Long point (up to 10 mtr..)
231Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it"s ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheet"s & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure "A" attached with this BSR
232On board
233Medium point (up to 6 mtr.)
234Long point (up to 10 mtr..)
235Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure "A" attached with this BSR
236Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure "A" attached with this BSR
237Blanking plate
238Modular MCB 6 A to 32 A DP (IS:8832 marked)
239Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure "A" attached with this BSR
2405 step fan regulator 2 Module 360 dgree rotating
241Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure "A" attached with this BSR
2421 x 1.5 sq.mm
2432 x 2.5 sq. mm. + 1x1.5sqmm
2442 x 4.0 sq. mm. + 1 x 2.5 sq. mm
2452 x 6.0 sq. mm. + 1 x 2.5 sq. mm
2464 x 10.0 sq.mm
2474 x 6.0 sq.mm
2481 x 16.0 sq.mm
2491x 4.0 Sq.mm.
250Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick  conforming to IS-8623-1 & 3 /  IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp.  insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set  of suitable rating and din bar,masking sheet,  making internal DB  terminations with copper lugs, Ferrules,  detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure "A" attached with this BSR
251Glazed door (Three phase) IK-09 and IP-43 with Metal end box
2526 Way
253Glazed door (single phase) IK-09 and IP-43 with Metal end box
2548 Way (8+2)
25512 Way (12+2)
256Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure "A" attached with this BSR
257Single pole MCB (With B/C curve tripping Characteristics)
2586 A to 32 A rating
259Double pole MCB(With B/C curve tripping Characteristics)
26040 A rating
261Four pole MCB(With B/C curve tripping Characteristics)
26250/63 A rating
263S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure "A" attached with this BSR
26420 mm
26525 mm
26640 mm
267Making of hole in wall (brick/stone) of required and placing NP-2 RCC pipe ring of required size for housing exhaust fan and making good the same, with cement plaster required of following size. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
268Up to 457 mm size
269P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure "A" attached with this BSR
270Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
271300 mm sweep(900/1400 RPM)
272P & F of Gravity Louver shutter of superior quality made out of frame of18 swg M.S. sheet & Louvers made from 24 swg MS Sheetwith enamel paint including cost of nuts, bolts, etc as reqd.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
273Up to 380 mm size
274Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy = 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.=0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
2751170mm(+/-10%) LED batten with min. lumen output 2200 lm
276Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of = 110 lm / watt, THD < 10 % , Pf.=0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing.
277OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
278Surface Mounting (with extruded alumn. Housing )
279Minimum lumen output 650 lm
280Minimum lumen output 1950 lm
281Providing & Fixing of IP20, 2"x2" LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of = 120 lm/Watt ,THD < 10 % , p.f.=0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing.
282OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
283Surface Moutning
284Minimum lumen output 3600 lm
285Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
2861200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 )
287Providing & Fixing ofextra down rod of 15 mm dia . ERW (Electrical resistance welded ) of 1.6mm nominal thick medium duty steelpipe including cutting, threading, drilling, fixing quarter pin etc as reqd.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
288Providing & Fixing of 400 mm SweepBLDC technology Oscillating type Wall mounting / Pedestal typefans with Three speed, ON andOFF position, Double Wall bearing withfront and back 120 or moreribs guard; Three no.blades, noise level should be <= 75 dB,including fixing with anchor bolts, making connection testing etc. as required. ( With Remote ) All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
289Wall mounting type with Service value 2.0 CMM /W, Min. Air Delivery 71 CMM
290Providing & Fixing ofof Double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
291300 mm sweep
292Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have it"s own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure "A" attached with this BSR
29335.0 Sq. mm 3.5 core
29410.0 Sq. mm 4.0 core
29510.0 Sq. mm 2.0 core
296Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :-
297(a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole
298(b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts
299© Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt
300(d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm.
301(d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book.
302(e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
30317.2 mm thick and 3 Mtr. Long
304Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cu purity purity >95%thimble etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
3058 SWG copper Wire
3068 SWG tinned copper Wire
307Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min = 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
308LED Street Light fixture with Minimum lumen output 2450 lm
309LED Street Light fixture with Minimum lumen output 7500 lm
310LED Street Light fixture with Minimum lumen output 11225 lm
311Providing & Fixing of Street light bracket made out from following size of " B " class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
31232 mm Dia.
313Supply and erection of Galvanized Iron pole with galvanizing done in single dipping (Average coating thickness Minimum 65 Microns) Swaged tubular pole conforming to IS: 2713-1980 (part I to II) with galvanised base plate, The pole shall be made from steel tube & Pipe (IS:1141, Fe 410) including excavation of the pit and filling the same with C.C. of M-20 grade (1:1.5:3) from base plate to 50 cm above ground level, with the help of steel frame not less than 40 cm dia up to 114.3mm outer dia and 50 cm beyond 114.3mm outer dia around the pole. Duly finished with cement plaster, earthing terminals, cable entry with 32 mm dia. "B" class GI cable sleeves complete as required. of following height & designation. ( See Table P - 02 for specs. ) All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR.
3147.5 Mtr. ( 410 SP - 5 )
315Add for supply and fixing of Pole OEM fabricated Galvanized Overhang of following size over the existing poles. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR.
31688.9 mm OD x 3.25 mm thickness
317SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure "A" attached with this BSR
3184 pole MCCB With Thermal Magnetic release
319up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting,
320160 Amp , 25 kA, adjustable O/L & adjustable S/C setting,
321Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
322Electrolytic grade (Cu-ETP) Tin Coated annealed copper bus bars IACS 100% grade
323SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-
324(a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided
325(b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.
326[c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra )
327(d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram.
328(e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.
329(f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra )
330(g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out.
331(h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
332Providing & Fixing of IS: 13875 & IEC :61326 confirming LED Digital type(up to 500) V range Volt meter / Direct- Ammeter /CT oertated ammeter/ Frequency meter / KWH meter / Multi Function Meter / Power analyzer of class 1 accuracyas per IS : 1248 of size 96mm x 96 mm including making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
333Three phase Ammeterwith Inbuilt Selector Switch
334Three phase Voltmeter with Inbuilt Selector Switch
335Providing & Fixing of BIS approvedCurrent Transformeras per PWD specification for electrical Works ,ISI marked as perIS 2705-1992/ conforming to IEC 60044-1, with secondary terminalof CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as requiredCurrent transformer Ring Type Tape Wound/Resin Cast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
336Ring type tape wound CT
337C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA
338Providing & Fixing of selector switch of 10 A for voltmeterusing high grade engineering materialto international standards with cam assemblyinsulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided . contact assembly is of operating temp range -25 degree C to 55 degree C, frequency upto 10 KHz. switch life under std. op. conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour including making connection etc.as required . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
339Voltage Between Phases with OFF ( 4 Position )
340Providing & Fixing of CT linked selector switch of 10 AforAmpere meter (4 position )using high grade engineering materialto international standards with cam assemblyinsulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided . contact assembly is of operating temp range -25 degree C to 55 degree C, frequency upto 10 KHz. switch life under std. op. conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour , including making connection etc.as required .All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
341Providing & Fixing of110/220 V, unibody LED Indicatinglamp IEC 60947with integral circuit, IP 65 above panel &IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min.29 mm, contact material phospher bronze for Led, PCB contacts shall be ofbrass (tin plated), impulsedielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDCincluding connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
342Red/yellow/Green colour
343Blue / white Colour
344Providing & Fixing of ding dong/musical chime bell as per PWD specification for electrical Works, including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
345Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
3466 kg
347Providing & Fixing of Electricalinsulating rubber matts as per PWD specification for electrical Works, ISI marked confirming to IS: 15652 /2006with one sideanti skid abberation marks and pasting the mat with synthetic rubber adhesive as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
34811 KV,Class B 2.5 mm thick with proof voltage 22 KV AC (rms) and Break Down Voltage45 KV AC (rms)
349SITC of RO water system with Filteration stage = Particalate filter - Membrane life enhancer filter - sediment filter - Pre carbon filter - RO membrane filer - Post carbon filter . Input power - 230 V AC , 50Hz , Percentage of Rejection TDS-90% or better having following fiturees (a) Double purification by RO with ESS or latest techonology with TDS indicator . (b)Spin welded RO membrane Housing to prevent tempering (c)Push fit components for leak proof perfomance (d) Fully automatic operation with auto startand auto off (e) SS/ ABSconstruction for corrosion free lifespan (f)nEqually suitable for water from all bore wells , overhead storage tanks,water tankers and even municipal tapos (g) RO membrane Flushing - Auto Flush @ Every Start ., Every Stop and every One hours of working for one minute . complete in all respect , with following capicity Make : Kent / Eureka Frobes / Ion Exchange / Electrolux / Voltas
350P & F in position frame made out of M.S. angle (riveted or welded) finished with two coats of red oxide and two coats enamel paint including cutting, welding, holes etc.of following sizes as required.For additional technical parameters of product / work refer Annexure "A" attached with this BSR
35140mm x 40mm x 5mm
352Pipe Earthingas per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. " B " class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 with perforated holes of 12 mm dia ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. and embodying the pipecomplete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
353Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min = 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
354LED Street Light fixture with Minimum lumen output 3700 lm
355Supply & Laying following size" B " class ,G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with accessories like bend, socket etc.for laying earth conductor/ strip / cable in ground/ surface/ recess as required.All as per pre approved by Engineer in charge.(Earth Excavation will be Paid Extra)All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annex ure "A" attached with this BSR .
35632mm dia
357Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix
358Random Rubble stone masonry with hard stone in superstructure aboveplinth level and upto five levelabove 30cm. thick walls in : Cement Mortar 1:6 ( 1-Cement : 6-Sand).
359Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcement for Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. M20 grade Nominal Mix / Design Mix
360Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish : 25 mm thick
361Finishing wall with water proofing cement paint of approved brand and manufacture and or required shade to give an even shade including all scaffolding
362New Work ( two or more coats applied @ 3.84 Kg./ 10 Sqm.)
363Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide
364Extra if square, rectangular hollow tubelar sections are used or grill made by flats only
365Add for each wire line over basic item (P/f barbed wire in Y angle in 7 rows)
366Painting with synthetic enamel paint of approved brand and manufacture togive an even shade : Two or more coats on new work
367Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete
368Finishing walls with Acrylic Smooth exterior paint of required shade including all scaffolding. New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm ).
369Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding: Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect.
370New work (Two or more coats applied @ 3.84 kg/10 sqm).
371P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make, P.V.C Waste pipe with PVC nut 32 mm complete including cutting & making good the wall : Size 580 mm x 450 mm
372Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge.
373Dismantling stone slab/ terrazo chip flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 meters lead.
374Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
375Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer-in-charge
376Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge:
377Taking out doors, windows and clearstory windows shutters (steel or wood) including stacking within 50 meters lead:
378Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meter lead.
379Mehrab & Chatri
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail