Tender For Work Of Purchasing Material For Redressal Of Electricity Related Complaints, ganganagar-Rajasthan

Department Of Local Bodies has published Tender For Work Of Purchasing Material For Redressal Of Electricity Related Complaints. Submission Date for this Tender is 03-10-2023. Miscellaneous Fasteners Tenders in ganganagar Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

39969410
Tender For Work Of Purchasing Material For Redressal Of Electricity Related Complaints
Open Tender
Indian
Rajasthan
ganganagar
03-10-2023

Tender Details

Work Of Purchasing Material For Redressal Of Electricity Related Complaints , Supply 5.5 Mtr Aluminium Ladder , Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of Breaking Capacity Not Less Than 10 Ka (B/ C Tripping Characteristic As Per Type Of Load And Site Requirement) 4Kv Impulse Withstand Voltage, As Per Pwd Specification For Electrical Works With Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm. , Conductorline Load Reversibility, Label Holding Facility , Ip 20 Contact Protection And Fitted With Existing Distribution Board/Sheets, Min. Operation 20,000 Upto 32 A Rating And 10,000 Upto 63 A, 5000 For 80 A Rating Including Making Connections, Testing Etc. As Required. . Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . E060110 Single Pole Mcb E060115 50/63 A Rating , E110200 Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Unarmoured / Armoured Copper Cable Of 1.1 Kv Grade As Per Pwd Specification For Electrical Works In Existing Rcc / Hume / Stoneware / Pvc Pipe/ Open Duct/Cable Trench With Filling Of Excavated Earth In Trench , On Existing Cable Trays Or On Surface Etc. Including Making Necessary Connection, Testing Etc. As Required Of Size And As Per Points (A), (B), (C), Mentioned Below:- (A) Copper Conductor Of Electrlytic Grade Copper, Purity >99.97 % Isi Marked As Per Is:1554 P-I / Is :7098 P - I (B) Conductor Shall Made Of Copper Rods Confirming To Is 613-1964, Is 3975-1999 For Armouring Of Cables In Armoured Cable Items , Is 5831 For Sheath, Is 10810 (Part 0 To 64 ) For Testing Procedures (C) Oem Must Have Iso 9001 & 14001 Certifications & Its Own In House Nabl Lab Setup For All Testing Facilities For Cables . Appropriate Type Test Certificate / Oem Test Report Shall Be Submitted . All Above As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . E110210 Un-Armoured E110216 16.0 Sq. Mme110216a 1 Core , E100200 Providing & Fixing Of Iso Certified Company Made Tp&N 415 V Ac23a Front Handle Operated Switch Disconnector Fuse Unit, Cubical Type, With Metallic Enclosure, As Per Pwd Specification For Electrical Works Conforming To Is/Lec 60947-3 : 1999 With Hbc Fuses Including Making Connections With Lugs, Testing Etc As Required. Appropriate Type Test Certificate / Oem Test Report Shall Be Submitted . All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . E100204 200 A Rating

Key Value

Document Fees
INR 1000 /-
EMD
INR 2520.0 /-
Tender Value
INR 5.04 Lakhs /-

BOQ Items

Name of Work: ??????? ??????? ???????? ?? ???????? ???? ??????? ???? ???? ?? ?????
Sl. No. Item Description
1Supply 5.5 Mtr aluminium ladder
2Providing & Fixing of 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C tripping characteristic as per type of load and site requirement) 4KV impulse withstand voltage, as per PWD specification for electrical Works with ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductorline load reversibility, label holding facility , IP 20 contact protection and fitted with existing distribution board/sheets, min. operation 20,000 upto 32 A rating and 10,000 upto 63 A, 5000 for 80 A rating including making connections, testing etc. as required. . OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . E060110 Single pole MCB E060115 50/63 A rating
3E110200 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Unarmoured / Armoured copper cable of 1.1 KV grade as per PWD specification for electrical Works in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points (a), (b), (c), mentioned below:- (a) Copper conductor of electrlytic grade copper, purity >99.97 % ISI marked as per IS:1554 P-I / IS :7098 P - I (b) conductor shall made of copper rods confirming to IS 613-1964, IS 3975-1999 for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures (c) OEM Must have ISO 9001 & 14001 certifications & its own in house NABL lab setup for all testing facilities for cables . Appropriate type test certificate / OEM test report shall be submitted . All above as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . E110210 Un-armoured E110216 16.0 Sq. mmE110216A 1 core
4E100200 Providing & Fixing of ISO certified company made TP&N 415 V AC23A front handle operated switch disconnector fuse unit, cubical type, with metallic enclosure, as per PWD specification for electrical Works conforming to IS/lEC 60947-3 : 1999 with HBC fuses including making connections with lugs, testing etc as required. Appropriate type test certificate / OEM test report shall be submitted . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . E100204 200 A rating
5???? ????
6????? ????? 2X3 ???
7??????
8?????? ??????
9?????
10???? ???
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail