| Sl. No. | Item Description |
| 1 | Earth work excavation for foundation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by thedepartmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification. |
| 2 | Earth work open excavation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the excavated earth with a lead of 10 mts. within the compound in places shown by the departmental officers and clearing and levelling the site, etc., complete complying with standard specification. |
| 3 | Supplying and filling in foundation and basement with filling crushed stone sand in layers of not more than 15cm thick, well rammed, watered and consolidated etc., complete complying with standard specifications. |
| 4 | Refilling with excavated earth other than crushed stone sand with an initial head load of 100 mts. and depositing the earth as shown by the departmental officersin layers of not more than 15 cm thick well rammed, watered and consolidated etc. complete complying with standard specification |
| 5 | Supplying and filling in foundation andbasement with Filling Gravel in layers of not more than 15cm.thick well watered and rammed and consolidation etc., complete complying with standard specification and directed by the departmental officers. |
| 6 | LOOSE BOULDERSEarth work excavating and depositing on bank withinitial lead of 10 m & initial lift of 2m in loose boulders in excavation of various size 150mm to 625 mm |
| 7 | Cement concrete 1:5:10 (One cement, five crushed stone sand and ten aggregate) using 40mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15cm thick, well rammed, consolidated and using etc., complete complying with standard specification |
| 8 | Cement Concrete 1:5:10 (One cement, Five M.sand and Ten hard broken stone) using 40 mm gauge hard broken jelly for flooring including laying,consolidating, finishing, rendering the top surface rough to receive the floor, curing, etc. complete complying with standard specification. (The rate is inclusive of necessary planking for panellingwherever necessary and as directed by the departmental officers |
| 9 | Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oakjoists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid) |
| 10 | Supplying and Erecting, Steel Centering for sides and soffits including supports and strutting upto 3.29m height for plane surfaces as detailed below in all floors with all cross bracings using mild steel sheets of size 90cmX60cm andBG 10 gauge stiffened with welded mild steel angles of size 25mmX25mmX3mm for boarding laidover silver oak joists of size 10cmX6.50cm spaced at about 90cm centre to centre and supported by Casurinaprops of 10cm to 13cm dia spaced at not less than 75cm centre to centre at sutiable intervals etc., complete in all floors as directed by the departmental officers complying with standard specifications.The payment for centering shall be made only after the concrete laid.The retrieved materials should be taken back by the contractor.- |
| 11 | Plane surfaces such as RCC floor slab, roof slab, rectangular, square, Tee or Ell beam, lintels, bed blocks staircase waist slab, landing slab, landing beams, portico beams, portico slab etc., |
| 12 | For plane surfaces such as vertical slab, side slabs of boxing, vertical drops, facia, vertical wall, etc. |
| 13 | Plane surface such as RCC square or rectangular columns, top and bottom slab of sunshade, boxing sill slabs, etc., |
| 14 | Providing additional strutting to centering of RCC slabs of plain surface for every additional 1.0 metre height or part thereof but not less than 30 cm, over the initial 3.00 metre height from floor level using casurina props of 10cm to 13cm dia including cross bracing etc., complete complying with standard specification and as directed by the department officers. |
| 15 | Providing and laying in position, standardised concrete Mix M.20 Grade in accordance with IS:456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/ms and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m.) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials). |
| 16 | Foundation and basement |
| 17 | Super Structure in Ground Floor |
| 18 | Super Structure in First Floor |
| 19 | Super Structure in Second Floor |
| 20 | Super Structure in Third Floor |
| 21 | Super Structure in Fourth Floor |
| 22 | Super Structure in Fifth Floor |
| 23 | Super Structure in Sixth Floor |
| 24 | Providing and laying in position, standardised concrete Mix M-25 Grade in accordance with IS 456 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 350 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg. of M.sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials). |
| 25 | Foundation and basement |
| 26 | Super Structure in Ground Floor |
| 27 | Super Structure in First Floor |
| 28 | Super Structure in Second Floor |
| 29 | Super Structure in Third Floor |
| 30 | Super Structure in Fourth Floor |
| 31 | Super Structure in Fifth Floor |
| 32 | Super Structure in Sixth Floor |
| 33 | Super Structure in Seventh Floor |
| 34 | Plain Cement Concrete 1:2:4 (one cement, two M.sand and four hard broken stone jelly) using 20 mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers. For Foundation and Basement |
| 35 | Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no crushed stone sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers.- |
| 36 | Super Structure in First Floor |
| 37 | Super Structure in Second Floor |
| 38 | Super Structure in SeventhFloor |
| 39 | Supplying, fabricating and placing in position Mild steel or Ribbed tor steel in all size for all RCC works as per the design given including cost of steel and binding wire in all floors etc., complete complying with standard specifications.(The contratctor will have to make his own arrangements for the supply of MS plain rod / RTS rod and binding wire) |
| 40 | Supplying and fixing in position best approved ISI quality PVC Rainwater Downfall pipes having working pressure of 4kg/cm2 including cost of PVC pipe, with necessary shoes, bends, nails, teakwood plugs, screws etc, and fixing of cast iron gratings of required dia metre and special clamps at junction of parapet and the RCC roof slab including finshing neatly etc., complete.The rate shall be inclusive of costof removable cast iron gratings. The size of teak wood plugs to be used shall be 150mm x 25mmin front and200mm x 75mm in rear and all other sides to a depth of 100mm.The PVC pipe shall be fixed with teakwoodplugs by means of \"U\" Clamps using brass screws. Special types of \"U\" clamp at the centre of the pipeline shall be fixed in addition to those for more than 3 metre pipe length complying with standard specifications. |
| 41 | One floor - 110mm dia |
| 42 | Two floor - 110mm dia |
| 43 | Two floor - 160mm dia |
| 44 | Seven floor - 160mm dia |
| 45 | Brickwork in cement mortar 1:5 (One cement and five crushed stone sand) using best quality IInd class ground moulded chamber burnt bricks of size 9”x4?”x2¾“ for the following including curing etc., complete complying with standard specifications. -For foundation and basement |
| 46 | Brickwork in cement mortar 1:6 (One cement and Six crushed stone sand) using best quality IInd class ground moulded chamber burnt bricks of size 9”x4?”x2¾“ for the following including curing etc., complete complying with standard specifications. |
| 47 | Super Structure in Ground Floor |
| 48 | Super Structure in First Floor |
| 49 | Super Structure in Second Floor |
| 50 | Super Structure in Third Floor |
| 51 | Super Structure in Fourth Floor |
| 52 | Super Structure in Fifth Floor |
| 53 | Super Structure in Sixth Floor |
| 54 | Super Structure in Seventh Floor |
| 55 | Brick partition wall using best quality IInd class Ground moulded chamber burnt bricks of size 9”x4?”x2¾“ in Cement Mortar 1:3 - One Cement and threeCrushed stone sand - including supplying and fxing hoop iron reinforcencement if considered necessary by the departmetal officers as directed etc., complete complying with standard specifications (The hoop reinforcement will be mesured & paid separately) |
| 56 | For Super Structure in Ground Floor in 11.50cm thickness. |
| 57 | For Super Structure in First Floor in 11.50cm thickness. |
| 58 | For Super Structure in Second Floor in 11.50cm thickness. |
| 59 | For Super Structure in Third Floor in 11.50cm thickness. |
| 60 | For Super Structure in Fourth Floor in 11.50cm thickness. |
| 61 | For Super Structure in Fifth Floor in 11.50cm thickness. |
| 62 | For Super Structure in Sixth Floor in 11.50cm thickness. |
| 63 | Damp proof course with Cement Mortar 1:4 (One Cement and Four crushed stone sand) 12mm thick mixed with best approved quality water proofing compound conforming to Indian Standard specification as specified by the departmental officers at 2% by weight of cement used and finishing, curing etc. complete complying with standard specification. |
| 64 | Plastering with Cement Mortar 1:5 (One cement and Five P.sand), 12mm thick mixed with Bonding agent Cebex112, Zydex -Zycrete 2X or other Equalent compound conforming to BIS at 200ml of One cement bag (50kg) for increased workability and air entrainment used finishing in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers. |
| 65 | Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three P.Sand) 10mm thick mixed with Bonding agent Cebex112, Zydex -Zycrete 2X or other Equalent compound conforming to BIS at 200ml of One cement bag (50kg) for increased workability and air entrainment used finishing including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the departmental officers |
| 66 | Plastering the surface of walls with Cement Mortar 1:3 (One cement and Three P.sand), 20mm thickwithBonding agent Cebex112, Zydex -Zycrete 2X or other Equalent compound conforming to BIS at 200ml of One cement bag (50kg) for increased workability and air entrainment used finishing in all floors including curing etc., complete complying with standard specification Conforming to BIS at 2% by weight of cement used including finishing,curing etc., Complete in all floor complying with standard specification and as directed by the departmental officers. |
| 67 | Providing Polymer Coating (Water Proof Coating) for sunken Portion of toilet with following specification and the surface shall be cleaned to remove all dust, foreign, matters lose materials or any other deposits of contamination by rubbing with wire brush.Slurry: Dry blend and polymer liquid blend shall be mixed into the desired ratio as per recommendation of the supplier. The mix shall be stirred throughly until no bubbles remain in the mix. Any lumps found in mix shall be removed.Apply first coat of polymer modified cementitious slurry by brush on wet cleaned surface. After drying, second coat shall be applied on the first coat as directed by the departmental officers etc. The rate inclusive of cost of materials and labour, etc., complete. |
| 68 | Stainless Steel (Salem Stainless Steel) Door Frame (Box Section using Stainless Steel Plate of 1.6mm thick) of size 100mm x 60mm with a rebate of 30 / 35mm x 15mm on one side of the frame including supplying and fixing dovetail splayed end stainless steel hold fast etc., with one coat of zinc chnomate yellow primer and filling the inside hallow portion with cement concrete 1:2:4 using 20mm HBG stone jelly etc,complete complying with standard specification. |
| 69 | CRCA Door Frame (Box Section using Stainless Steel Plate of 1.6mm thick) of size 100mm x 60mm with a rebate of 30 / 35mm x 15mm on one side of the frame including supplying and fixing dovetail splayed end stainless steel hold fast etc., with one coat of zinc chnomate yellow primer and filling the inside hallow portion with cement concrete 1:2:4 using 20mm HBG stone jelly etc,complete complying with standard specification. |
| 70 | Supplying and fixing solid core particle board flush shutter (Single Leaf Size 1.00mx2.10m) of nominal thick of 35 mm with necessary T.W. internal lipping conforming to IS 2302 with both sides alround commercial ply 35mm thick including supplying and fixing cost of wind appliances and furniture fittings such as 1no .300x12mm aluminium tower bolt 1nos. 200x12mm aluminium tower bolts 1no. 250x16mm aluminium aldrops, 2 nos. 200mm ‘D’ type aluminium door handle and door stopper with bush etc., complete as directed by the departmental officers. |
| 71 | Supplying and fixing solid core particle board flush shutter (Double Leaf of Size 1.50x2.10m) of nominal thick of 35 mm with necessary T.W. internal lipping conforming to IS 2302 with both sides alround commercial ply 35mm thick including supplying and fixing cost of wind appliances and furniture fittings such as 1no .200x12mm aluminium tower bolt 2nos. 300x12mm aluminium tower bolts 1no. 250x16mm aluminium aldrops, 3 nos. 200mm ‘D’ type aluminium door handle and door stopper with bush etc., complete as directed by the departmental officers. |
| 72 | Supply & fixing of WPC (Wood Polymer Composite) Frame extruded with size 75mm x 50mm. The single core door made of rigid WPC compound with minimum Bulk Density of 900 KG/ Cub.Mt. & shore hardness of 55. Supply & fixing ofWPC door shutter, extruded as a single core board with rigid WPC compound with the thickness of 25mm (+/- 1mm) & minimum Bulk Density of 550 KG/ Cub.Mt. & shore hardness of 55. For the aesthetic appearance, the door shall be a printed digitally on one side of the shutter and the design is as decided by the Engineer in-Charge of the department. The WPC door shall be fixed onto the WPC frame with 3 Nos of 5” SS Hinges and the door shall have 2 towerbolt on one side and 1 towerbolt or aldrop on other side for locking system and 2 numbers of handle on the either side of the door shutter, all made of aluminium. |
| 73 | Supply & fixing of WPC door shutter, extruded as a single core board with rigid WPC compound with the thickness of 25mm (+/- 1mm) & minimum Bulk Density of 550 KG/ Cub.Mt. & shore hardness of 55. The door shall be a plain matt board as decided by the Engineer in-Charge of the department.The WPC door shall be fixed onto the Aluminium “G” type channel with Wheel and the door shall have 2 Hooks in SS, 2 Handles 4” in SS.(Sliding door) |
| 74 | Supplying, fabricating and fixing in position factory made Stainless Steel Flush Door Shutter 35mm thick using SS 304 Grade 1.6 mm thick, Stainless Sheets on both sides (Equivalent to IS 6911-04 Cr. 19, Ni 9) minimum 8-8.5% nickel and 18% chromium sourced from original stainless steel manufacturer with view panel size 30mm x 45mm made up of 6mm thick clear toughened glass fitted with double side adhesive tape and finished with dowconing silicon sealant, floor pring for each shutter, consealed tower bolt, suitable stainless steel locking arrangement and other necessary furniture fittings of approved quality. The vertical styles and other frame members and cross stiffeners shall be of same quality stainless steel box section of suitable size and thickness with proper core material as prescribed by the Departmental Officers |
| 75 | Providing and fixing of 1.2mm thick Lead Lining Door for X-Ray Rooms, Scanning Rooms with Mild Steel Door Frames 105mm x 57mm X 18 G and 12 G x 50mm Shutter made of GI with PWG finish and honey wool insulations with SS 101mm x 75mm x 3mm SS 304 Ball Bearings Butt Hinges, Mortice Sash Lock ML 100A,50mm BS, 85mm centre, CL 207 : Key & Knob 70mm, 5 Pin Cylinder with Handle SS Finish (Dorma Make), Heavy Duty Door Closer, Frames fixed wih walls using Mortice Sash Lock ML 100A, 50mm BS, 85mm centreCL207: Key & Knob 70mm, 5 Pin Cylinder with Handle SS Finish (Dorma Make) all neccesary accessories and fittings as per the required and as per the approval for the Department Officer |
| 76 | UPVC Window Specification:Fabrication, Supplyandfixing in position UPVCfixed Three track Sliding window (Un-Plasticized Polyvinyl Chloride) from the profilethe size of outer frame top, bottom and slids with tublar section of size 112mm x 62mm at 1.57 kg/m. Two nos the siliding sash of size 46 x 62mm @ 0.72 Kg/m Both Vertical and horizontal members. The open sash is fitted with every sliding sash of size 70mmx 62mm. necessary rubber beadings are highly fitted for fixing the pin headed / Plain glass of 4mm thick. The cost includes dismangling RCC columns, Masondry wherever necessary with poer drill to the extend required and make good the damaged portion etc.,The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work. |
| 77 | UPVC Window Specification:Fabrication, Supplyandfixing in position UPVCfixed Two track Sliding window (Un-Plasticized Polyvinyl Chloride) from the profilethe size of outer frame top, bottom and slids with tublar section of size 112mm x 62mm at 1.57 kg/m. Two nos the siliding sash of size 46 x 62mm @ 0.72 Kg/m Both Vertical and horizontal members. The open sash is fitted with every sliding sash of size 70mmx 62mm. necessary rubber beadings are highly fitted for fixing the pin headed / Plain glass of 4mm thick. The cost includes dismangling RCC columns, Masondry wherever necessary with poer drill to the extend required and make good the damaged portion etc.,The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work. |
| 78 | UPVC Ventilator Specification:SupplyingandfixingUPVC(Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profilethe size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles arereinforcedwith GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned.Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work |
| 79 | Fabrication, supply and fixing in position of \"N\" type ventilators using M.S. angle of size 25 x 25 x5 mm for frame and M.S. Flat of size 20 x 3 mm for fixing the weld mesh and using 25 x 22 x3 mm \"T\" section for frame glass.Special type of Hold fast welded to the frame of 45 degree inclined towards centre for wall and fxing the weldmesh 25mm square including cost of 3mm thick pinheaded glass panes for all panels and fixing the glass panels with necessary clips & putties with required bolts, nuts and washers and one coat of red oxide primer etc. including necessary dismantling, making holes in RCC columns, beams, masonry wherever necessary with power drill to the extend required and made good to the original conditions after fising as directed by the departmental officers. |
| 80 | Supplying, fabricating and fixing in position of Aluminium With powder coating of any colours Mat finilsh Fixed Glazing the glass used shall be of 5 mm thickness. The Aluminium Section are to be anodised under electrically controlled condition as per IS 1868/1962 for an anodic film thickness of 15 microns. All the materials should be got approved by got approved by the Executive Engineer before execution of works. |
| 81 | Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia StainlessSteelpipepostof1.00mmthick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete.The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete |
| 82 | Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase near wet riser using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick will be provided with tubular supports made of 304L Grade Stainless Steel pipe of 25mmdiaof1.60mmthickweldedtotherailing. The supports will be groutedinto the wall and provided with 93.00mm thick Stainless Steel circular base plate of 304Grade. The rate shall included for grouting into concrete with necessary supportingarrangementsthehandrailinfloor polishing buffing, bonding, cutting, grinding, conveyance, welding charges, electrical charges, etc. complete |
| 83 | Supplying and fixing in position steel balustrades using 20mm square rods spaced at 150mm centre to centre so that the two balustrades in each step shall be placed centrally and the top of balustrades connected with the hand rails (cost of hand rail shall be measured and paid separately) by means of MS flats of size 40mm x 6mm in the groove 40mm x 6mm provided at the bottom of hand rail; the bottom of balustrades shall be fixed on to the top of step concrete.An additional MS flat of size 50mm x 6mm shall be provided at the centre of balustrades connecting all square rods to the entire length including cost of square rods, flat and applying one coat of red oxide primer to the iron surfaces, etc., complete complying with standard specification and as directed by the departmental officers. |
| 84 | Supplying and fixing 40mm dia GI pipe for staircase hand rail including labour charges for cutting, welding and fixing with MS flats (excluding cost of flat), etc., as directed by the departmental officers |
| 85 | Supplying and fixing GI pipe handrails for handicapped persons using 50mm dia GI pipe double handrail at a height of 800mm and 900mm from floor level with 25mm thick MS square rods as balusters embedded in the concrete and welded with pipe at 60cm centre to centre as shown in CA Job No. 9123 / 1 including cutting, welding, bending and fixing charges and applying one coat of red oxide primer for MS members as directed by the departmental officers |
| 86 | Supplying and Fixing M.S grill to opening corridor sides, ladder Entrance gate and Name board angles etc., Using necessary M.S flat for inner members and outer members which should be fixed to window members frames as directed by departmental officers inclusive of cost of providing one coat of best quality red oxide primer. -The design of M.S. grill should be got approved from departmental officers before use on works.- |
| 87 | Supplying and erecting pull and push type rolling shutter with ISI make of approved size and section using 18 GI sheet.The shutter shall be painted with one coat of red oxide primer and the rate is inclusive of hood covers, transportation charges etc., ROLLING SHUTTERS (WITH ISI MONOGRAM) |
| 88 | Manual type |
| 89 | Gear operated type |
| 90 | EOT |
| 91 | Manufacturing supplying and fixing of steel door with the following specification MS angels of size 40x40x6mm are used for the outer frames and M.S. angles of size 35x35x5mm for the shutter frames stiffeners with 32 x 6mm M.S flat is provided at required intervals in the shutter frame. 18-gauge C.R. sheet laid as panel in the shutter and welded intact. M.S. flat 18x5mm is welded over the 32 x 6mm M.S. flat sandwitching the C.R. sheet in between additional stiffeners with 18x5mm M.S. flat is provided diagonally at the rear side of the shutter, 3nos. of hinges in case of single leaf and 6nos. of hinges in double leaves shutter to be provided 6nos. of holdfasts 120 mm in length made of angle section spliced at the ends are welded to the outer frames of the door. Tower bolts 2nos. one at the top and the other at the bottom are provided 1no. Aldrop is provided incase of double leaf door at lock rail section in the door in single leaf door, one more aldrop is provided in the inner lock rail section of the door One rotaing locking arrangements for the inner side of the door and additional provision for locking arrangements for lock is provided on the rear side of the door at an appropriate place.Incase of double leaf door M.S.Flat 32 x 3mm at 1.1Kg/m is provided on the one shutter t conceal the gap between the two shutters.at an appropriate place in the door. A tie bar is provided at the bottom of the frame to prevent twisting of frame during transportation and fixing. All members are given a coat of red oxide primer as directed by the departmental officers. The rate includes cost of all materials, labour charges, transportation to site of work, loading, un loading and all other incidental charges etc., complete |
| 92 | Dadooing with printed design colour glazed tiles of size 300 x 450 x 8mm set in Cement Mortar 1:2 (One Cement and Two m.sand) 10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers. |
| 93 | Supplying and fixing of SS Wall Cladding |
| 94 | Supplying and fixing of SS False Ceiling |
| 95 | Dadooing with Double charged Vertified tiles 600 x 600 x 8mm set in Cement Mortar 1:2 (One Cement and Two m.sand) 10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers. |
| 96 | Supply and fixing of PVC wall Corner beading etc., complete |
| 97 | Paving the floor with best approved quality fine polished Granite Stone Slabs for work table slabs of size 1200 x 600 of 18 / 20mm thick of Jet Black with machine cut edges laid over a cement mortar bed of 10mm thick using cement mortar 1:3 (One cement and three M.sand) fixing the slabs with required cement slurry and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments etc., The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification. |
| 98 | Dadooing with Special type GVT 1600mmx800mmx12mm best approved quality, white / colour glazed tilesset in Special type of adhesive and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers. |
| 99 | Paving the floor with best quality Double charged Vertified tiles 600 x 600 x 8mmapproved colour, shade and quality laid in cement mortar 1:3 (one cement and three M.sand) 20mm thick in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification.(The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 100 | Paving the floor with Induestrial Vertified tiles of size 600 x 600 x 10mm of approved colour, shade and quality and textured surface that offers excellent nonslip property with high coefficent of friction which is most suited for public places that encounter high trafic of patients, wheel chairs, stretcher etc laid in cement mortar 1:3 (one cement and three M.sand) 20mm thick in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification.(The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 101 | Providing Leather finished Granite slab Jet Black of similar varieties of approved colour for staircase treads and midlanding including nosing free all draft in all floors over a base layer of cement mortar 1;3 10 to 20mm thick the granite slab shall be laid over the cement mortar by applying color cement slurry in between mortar and slab the granite slabs re to be so laid that there shall be in line with other joint and uniform by cutting machine without any damage to the sides of corner of the granite slabs, the entire area at the that flooring so laid shall be neatly pointing with maching colouring cement at 1.80 kg/m2 etc., The Granite stone slbs and other materials to be used shall be got approved by the Rxecutive Engineer concerned before use on work etc., complete complying with standard specification and as directed by the departmental officers. |
| 102 | Paving the floor with anti-skid tiles of size 300x300x10mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three M.sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 103 | Flooring with Joint free Rectified Glazed Ceramic Flooring tiles 305 x 305 x 8mm laid over 20 mm thick cement mortar 1:3 (One Cement and Three M.Sand)base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.3 Kg. / sq.m. etc., complete complying with standard specification.(The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 104 | Providing granolithic floor finish of the following thickness with plain cement concrete 1:2:4 (One Cement, Two M.sand and Four aggregate) using 10 to 12mm gauge hard broken stone jelly including laying, finishing and the top rubbed smooth with power trawl, thread lining, curing etc. complete complying with standard specification and as directed by the departmental officers. (The rate is inclusive of necessary planking for panellingwherever necessary and as directed by the departmental officers) |
| 105 | 25mm thick |
| 106 | 40mm thick |
| 107 | Manufacturing, supplying and fixing Precast Reinforced Cement Concrete slabs of following thickness in RCC 1:2:4 (one cement, two M.sand and four aggregates), using following HBGS jelly excluding cost of reinforcement steel in position but including cost of moulding charges, casting of slab, finishing, curing and fixing in position in all floors etc., complete complying with standard specification and as directed. |
| 108 | 50mm thick |
| 109 | 75mm thick |
| 110 | Finishing the top of roof with one course of machine pressed tiles of size 230mm x 230mm x 20mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers |
| 111 | Brick jelly Lime Concrete 1:2:5 (One lime, two sand and five brick jelly ) using 40mm gauge brick jelly for flooring including laying, consolidating, finishing, rendering the top surface rough to receive the floor finish, curing, etc. complete complying with standard specification.(For flooring in toilet portioins except water closet portions) |
| 112 | Super Structure in Ground Floor |
| 113 | Super Structure in First Floor |
| 114 | Super Structure in Second Floor |
| 115 | Super Structure in Third Floor |
| 116 | Super Structure in Fourth Floor |
| 117 | Super Structure in Fifth Floor |
| 118 | Super Structure in Sixth Floor |
| 119 | Supplying and fixing fine polished cuddapah slab of 38 / 40mm thickness for cup-board arrangements including laying to correct alignment with necessary cement mortar and black powder etc, complete complying with standard specification and as direct. |
| 120 | Labour Charges for Full nosingCuddapah Slab Including Necessary Charges |
| 121 | Labour Charges for Full nosing Granite Slab Including Necessary Charges |
| 122 | Supplying and laying of Interlocking Paver Block Stone 63mm thick. Over a base layer of M.sand filling incl. Cost of materials laying and Labour charges etc., |
| 123 | Supplying and fixing Polycarbonate Sheet 6mm thick thick and steel tubular box section of 100x50x3mm of 1meter interval including priming coat fixing in position with all necessary accessories complete complying with standard specification and as directed by the departmental officers. |
| 124 | Supplying and fixing colour galvanum sheet roof of 0.47mm thick and steel tubular box section of 100x50x3mm of 1meter interval including priming coat fixing in position with all necessary accessories complete complying with standard specification and as directed by the departmental officers. |
| 125 | Supplying and fixing in position of Chain link - 2\" x 2\" using 10 Gauge Galvanised Iron Wire (of all sizes)etc.,complete. |
| 126 | Providing Cup-board Shutter using termite / water proof plywood of 19mm thick over which laminated sheet of 0.8mm thick fixed inside the shutter and 1mm thick fixed in the outside of the shutter using fevicol along with necessary furniture fittings, such as, hydralic hinges, tower bolt, handles, multi purpose locks etc., as directed by the Departmental Officers. The design pattern, water proof plywood, laminate sheet and other materials should be got approved from the Executive Engineer befoe use on work. |
| 127 | Fabrication and supplying of Steelrack of size 7\"x4\"x1½\", 1½\" x ¼\" -60x40x5mm L angle with holes provision for 6 plates of 18 gauge CRCA sheets, with stiffness for side and down of the panels in two different colours with bolt and nuts. The rate inclusive of cost of all materials, welding charges, bending charges, labour charges, electro powder coating, transportation as applicable and supply to worksite. |
| 128 | Supplying and painting the walls with two coats of wall putty as instructed by the departmental officers including preparation of surface curing, etc., complete in all floors complying with standard specifications (The wall putty shall be got approved by the Executive Engineer before use of work). |
| 129 | Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification. |
| 130 | Painting the wall two coats with approved weather proof Exterior Emulsion paint over one primer coat of over cement plastered wall surface ect., completecomplying with standard specification. |
| 131 | Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 132 | Painting new wood work with two finishing coats of synthetic enamel ready mixed paint of approved quality and colour over one coat priming coat in all floors including the cost of primer etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 133 | Fabricating Supplying and fixing in position of UPVC anodised 1/3rd fixed glazing 2/3rd prelaminated board of UPVC partition. The outer frames Outer frame: 63.50x38x3mm@ 1.72 kg/m,Centre mullions: 63.50x38x3mm@ 1.55 kg/m,upvc. Clips: 17.27x17.15x1.50mm @ 0.175kg/mg/m for intermediate vertical mullion 90cm c/c. Horizontal mullion at 1.00m 2.10m covered with 5.5mm thick plain glass with neccessary UPVC clips of size 17.27x17.15 x1.50mm @ 0.176kg/m and with required rubber beading etc., including necessary dismantling holes inRCC column,masonrywherever in necessary with power drills to the extent required and made good the damaged portion in good condition after fixing as directed by the departmental officers. All the UPVC sections should be anodised not less than 15 microns as ISI specification1868/1962 / and should be gotapproved by Executive Engineerbefore use. |
| 134 | Providing UPVC (Un-Plasticized Polyvinyl Chloride) Door: Providing and fixing casement doors fabricated from un-plasticized polyvinyl chloride (uPVC) sections.Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mm x 55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steel reinforced with 25 x 24 x 25mm steel reinforcement with a thickness of 1mm to have dimensional stability. The sash should be of 60 x 102mm. The mullion should be of 60 x 74mm. The profiles should have co-extruded seals.Hardware: All the hardware like friction stays, handles should be screwed with self tapping screws. The handles, locks should be designed so that they cannot be released from outside.Glazing: The window system should be glazed with 5mm plain float glass / 6mm bison lam. |
| 135 | Supplying and fixing following Ornamental Burma Teakwood entrance door as per the drawings and designs approved by the departmental officers. The outer frame of the door is 150mmx125mm teakwood. The main door shutter opening size is 3.00mx3.00m.The main door should be double leaves and each door shutter fully panelled.The door shutter outer frame of size 150mmx50mm teakwood. The door panells shall be of 50mm thick teakwood planks with ornamental designs approved by the Executive Engineer. The Lock rail shall be of 200x50mm tk teakwood. The top of the door to a height of 900mm finished with fixed glazing of approved pattern using 12mm thick toughened glass with MS grill. the sides of the door shall be fixed glazing of size 900mmx3900mm finished with 12mm thick toughened designed glass. All the door frames and fixed glazing frames are made out of 150mmx125mm teakwood of best quality. The door frames and shutters shall be given two coats of best approved quality melamine finish. The rate inclusive of cost of approved quality teakwood, 12mm thick designed toughened glass, brass hinges, brass tower bolts, brass aldrops, door stoppers, brass screws etc.,The cost includes cost of material, labour charges, conveyance charges, fixing charges,designing charges and glass design charges, electricity charges and all other incidental charges., etc. All materials should be got approved by the Executive Engineer before use on works. |
| 136 | Providing expansion joint in RCC floor slab for 12.5mm width using polysulphide as sealent on the top and bottom for a depth of 7.5mm each and packing the inner space using compressible non-absorbent filler materials including cost of labour for cutting and fixing filler materials and laying polysulphide sealent with necessary spatula etc., complete complying with standard specifications and as directed |
| 137 | Providing expansion joint 12.5mm width in RCC roof slabs between RCC twin beams using PVC water bar of 150mm wide centre bulb of 4mm to 6mm thickness of approved quality and brand and including filling the inner space with suitable non-absorbent flexible and well compressible filler materials of approved quality and covering the top surface with GI sheet 30cm wide and 1.6mm thick using phill plugs, GI screws, limpet cup washers, bitumen washers, etc., complete complying with standard specifications and as directed |
| 138 | Providing expansion joint of 12.5mm wide in between RCC twin columns from top of pedastal to full height including filling the inner space with suitable non-absorbent, flexible and well compressible filler materials of approved quality and brand; finishing the sides of RCC columns with polysulphide sealents for a depth of 7.5mm on either side covering the inner space filled with filler materials as above etc., complete complying with standard specifications and as directed. |
| 139 | Providing Anti-termite treatment to soil adjecent and under building foundation, plinth periphery of the building by application of chemicals of IS 63613 part I to IV in stages to suit the progress of work consist as per the detailed specification as below.Including breaking of termite mounds, making holes with crow bar, closing the holes after the treatment and including cost of chemicals, labour charges, transport and storing etc., complete and as directed by the departmental officers. |
| 140 | Supplying and Fixing of Autopsy Table Sp 100 DELUX type stainless steel with radius isside corners for easy clean up. It is manufactured without revets, bolts or other devices so that work surface remains smooth and prevent cumulation of bacteria, rist operated stainless steel FAUCET with hot and cold water flow control valves, double bowl sink, 3 solid stainless steel sliding body support, wooden head rest, tale length 9” width 0” approx engraved measurement scale on one side for easy marsuent of cadavr, REVERSE FLOW. Hydro aspirator with built in vacuum breaker and mounted on six bullet legs for study performance. This rate Exclusive of GST tax etc., Complete with standard specification. |
| 141 | Supplying and installation of Anutone / Topakustiks / Idea Tec / Wood Fit / Equivalent Brand of Acoustic Wooden Wall Panelling with fire retardant grade pine wood fibre slats of size 2430 x 128 x 16mm with lineal perforation of 2mm back lined with soundtex black acoustical fleece 0.27mm thick, 63 g / m2, tongue-groove edge for a seamless look, 5 test fire retardant grade with noise reduction coefficient not less than 0.75 NRC to absorb low and mid range frequencies from 125Hz to 4000Hz. GI strut CC50 frame work not more than 60 cm centre to centre using GI channels are fixed on the wall, over which an acoustic filling polywool material sound synth of 500 gsm density of 50mm thick has fixed and finally the panels are fixed and finished, so as to have an neat appearance as directed by the departmental offices. The cost includes cost of material, cost of Labours, scaffolding, transportation, conveyance, etc., complete complying to standard specication. |
| 142 | Supply and installation of Special type Anutone wood wool 15mm thick (or) Equivalent Brand of Acoustical False Ceiling of 50mm synth wool, square edge, glass fibre core fully encapsulated ceiling tile of size 595 x 595 x 20mm having volume density 120 Kgs / m3, weight 1.8 / 2.4 / 3 kg / m2 which is suspended by using 0.3mm thick skelet trelis T15 metal grid system. Skelet trelis T15 metal grid system of 600 x 600mm module includes skelet WA15 W30 wall angle with unequal flanges of 15 / 19mm, length 3000mm, fixed along the perimeter of walls with the help of nylon sleeves and suitable fasteners at 300mm centers. Then suspend the skelet MT15 W36 MainT with flange width 15mm, height 32mm and length 3600mm, from the soffit slab with help of soffit cleat and wire rod with leveling spring clip at 1200mm centres. Skelet CT15 W12 CrossT with flange width 15mm, height 26mm and length 1200mm is interlocked into the pre-cut slots in the Main T15 at 600mm centers in the perpendicular direction to the Main T15. Finally, the skelet CT15W06 CrossT with flange width 15mm, height 26mm and length 600mm are interlocked into the precut slots in the CT15W12 CrossT in direction parallel to the Main T15 to result in 600 x 600mm module. The subtex nubby square edge of size 595 x 595 x 20mm shall be placed into the grid size of 600 x 600mm. Ensure arrow marks behind the tiles are oriented in one direction to achieve uniform shade. The systems to achieve noise reduction coefficient not less than 0.9 NRC, so as to have an neat appearance as directed by the department offices. The cost includes, cost of material, cost of labour, scaffolding, transportation, conveyance, etc. complying to standard specification |
| 143 | Road arrangements : Excavation for Roadway and drainage - Excavation including removal and satisfactory disposal of all materias necessary for theconstructionof roadway and side drains in accordance with the specifications andthe lines, grades and cross sections shown in the drawings or as indicated by the Engineer box cutting for widening portion |
| 144 | Construction of Granular sub base by providing close graded material, mixing in a mechanical mix plant at OMC, carraige of mixed material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achive the desired density etc., complete. |
| 145 | Providing and Laying wetmix mecadam of 150 mm compacted thickness in 2 layers of 75 mm mm thick or else as specified on the prepared sub base with grade store aggregate and granular material of quality size and grading pasting in layer with motor grader and compaction with vibrating roller of 80/100 KN static weight and fine dressing for required grade and cross slope as shown on the drawing equipments safety measures as per MORTH & 406 |
| 146 | Providing and laying prime coat WMM surface using 7kg of Emulsion Bitumen(SS1) per 10 sqm for preparatory to another bituminous construction over it, including cost of material, labour charges, rentals for machinery, fuel and all other incidental charges etc., complete as perclause 502 of MORTH Rev-5 |
| 147 | Providing and laying Tack coat over WMM surface using 2.50kg of Bitumen emulsion per 10 sqm for preparatory to another bituminous construction over it including cost of material, labour charges, rentals for machinery, fuel and all other incidental charges etc., complete as per clause 503 of MORTH Rev-5 |
| 148 | Providing and laying 50mm consolidated thick bituminous macadem using 0.20 cum of 26.50-13.20mm,0.43 cum of 13.20-2.36mm and 0.08cum of 2.36mm & below size IRC metal with 37kgs of VG30/VG40 bitumen for premixing per 10sqm icluding cost and conveyance of all materials to CMP site, heating the bitumen and aggregate to required temperature and mixing them in required temperature in central hot mix plant 20-30 ton capacity, conveying the mix by tipper trucks to paver site, spreading the mix to uniform thickness of 50mm with mechanical paver to the specified grades and cross sections and consolidated by 8-10 tonne vibratory / Pneumatic roller to the required density etc., including labour for attending to paver to site etc., including hire charges and fuel charges for 20-30 t CMP with bitumen boiler, tipper trucks, paver finisher/ 9m paver finisher, vibratory / Pneumattic roller and all other tools and plant required, including fuel and all other incidental charges etc., complete as per specification using CMP as per clause 504 of MORTH Rev-5 |
| 149 | Providing and laying Bituminous Concrete to 30 mm thick using 0.13 cum of 19.00-9.50mm, 0.17cum of 9.50-2.36mm and 0.26 cum of 2.36 and below with 50.30 kgs of VG30 bitumen for premixing per 10sqm including cost and conveyance of all materials to CMP site, heating the bitumen and aggregate to requiredtemperature and mixing them in required temperature in central hot mix plant 20-30 ton capacity, conveying the mix by tipper trucks to paver site, spreading the mix to uniform thickness of 40mm with mechanical paver to the specified grades andcross sections and consolidated by 8-10 tonne Vibratory / Pneumatic Roller to the required density etc., including labour for attending to paver to site etc., including hire charges and fuel charges for 20- 30 t CMP with bitumen boiler, tipper trucks, Paver Finisher / 9m paver finisher, Vibratory / Pneumatic roller and all other tools and plant required, including fuel and all other incidental charges etc., complete as per specification using CMP as per clause 507 of MORTH Rev-5 - Grade-II |
| 150 | Providing and Laying of hot applied thermoplastic Compound 2.5mm thick including reflectorsing glass beads @ 250gms per sqm area. Thickness of 2.50mm exclusive of surface applied glass beads as per IRC 35. The finished surface to be level uniform and free from streaks and holes etc,. Compete as Per MORT&H Specification No. 803. |
| 151 | Drilling of Borewell in sedimentary strata of hard rock stone shale pebbles bolders etc., By first taking a pilot bore of 150mm dia and then enlarging to the required dia by direct or reverse rotary mud circulation method using rotary rigs, fuel labour and drilling bentonite and water required for dirlling at site. |
| 152 | upto 150m below GL |
| 153 | From 151 to 180m |
| 154 | From 181 to 210m |
| 155 | From 211to 240m |
| 156 | From 241to 270m |
| 157 | From 271to 300m |
| 158 | From 301to 330m |
| 159 | From 331to 350m |
| 160 | Supplying of best approved quality ofPVCcasing pipe of 6\" dia (Special Blue Pipes for Bore Well) for borewell with socket end to suit borewell of required depth -6kg/cm2best approved quality with ISI mark with necessary PVC coupling etc., |
| 161 | Supplying and fixing of suitable PVC endcap (6kg/cm2) for 6\" dia borewell of best quality with ISI mark |
| 162 | Supplying and fixing ofNylon Rope for holding the pumpset in position in to the bore hole including the cost of rope,transport to the site and tieing the motor and lowering in to standard specifications.The rope to be used on work shall be got approved by the Executive Engineer before use on work. |
| 163 | Supllying of best and approved quality of 50mm dia UPVC pipe including laying in the basement and tying with copper wire etc., complete complying with standard specification. |
| 164 | Supplying and erection of following submersible pump set with panel board of ISI make, Pumping water from openwell including transportation charges, erection charges etc., complete complying with standard specification and as directed by the departmental officers. |
| 165 | 5 H.P Submersible pump |
| 166 | 7.5 H.P Submersible pump |
| 167 | Supplying and erection of submersible wire 3x6 sqmm cable PVC insulated and sheathed 3core flat type copper cable with ISI make including erection inside the bore well and open run of clamping etc., completer complying with standard specification., as directed by the departmental offcers., |
| 168 | Supplying and fixing of 50mm dia of GM Non return valve with ISI make including cost of shellac thread etc., completer complying with standard specification., as directed by the departmental officers. |
| 169 | Supplying, laying and jointing UPVC Pipe (Un-Plasticized Polyvinyl Chloride) UPVC used for residential and home applications, water pressure in residential areas do not normally exceed the maximum tolerance. (Schedule-40) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) complete complying with standard specifications.The UPVC pipes shall be got approved by Executive Engineer before use on works. (Below Ground Level) |
| 170 | 80mm dia UPVC Pipe |
| 171 | 50mm dia UPVC Pipe |
| 172 | Supplying, laying and jointing 40mm dia UPVC Pipe (Un-Plasticized Polyvinyl Chloride) UPVC used for residential and home applications, water pressure in residential areas do not normally exceed the maximum tolerance. (Schedule-40) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, UPVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications.The UPVC pipes shall be got approved by Executive Engineer before use on works. (Above Ground Level) |
| 173 | Supplying, laying and jointing CPVC (Chlorinated Poly Vinyl Chloride) Pipe (Higher pressure rating with higher pipe thickness) Standard Dimension Ratio-11 of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing CPVC specials using CPVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, CPVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications.The CPVC pipes shall be got approved by Executive Engineer before use on works. (Above Ground Level) |
| 174 | 32mm dia CPVC Pipe |
| 175 | 25mm dia CPVC Pipe |
| 176 | 20mm dia CPVC Pipe |
| 177 | Supplying UPVC Specials in water supply arrangements (both in internal and external water supply arrangements |
| 178 | 50mm dia Elbow |
| 179 | 50mm dia Tee |
| 180 | 50mmx40mm Reducer |
| 181 | 40mm dia Elbow |
| 182 | 40mm dia Tee |
| 183 | 40mm dia Union |
| 184 | 40mm dia Bend |
| 185 | 40mm dia Coupler |
| 186 | 40mmx32mm Reducer |
| 187 | 40mmx32mm Reducer Elbow |
| 188 | 40mmx32mm Reducer Tee |
| 189 | 40mm Hex Nipple |
| 190 | Supplying CPVC Specials in water supply arrangements (both in internal and external water supply arrangements |
| 191 | 20mm dia Elbow |
| 192 | 25mm dia Elbow |
| 193 | 32mm dia Elbow |
| 194 | 20mm dia Tee |
| 195 | 25mm dia Tee |
| 196 | 32mm dia Tee |
| 197 | 20mm dia Bend |
| 198 | 25mm dia Bend |
| 199 | 32mm dia Bend |
| 200 | 20mm dia Coupling |
| 201 | 25mm dia Coupling |
| 202 | 32mm dia Coupling |
| 203 | 20mm dia Union |
| 204 | 25mm dia Union |
| 205 | 32mm dia Union |
| 206 | 20mm dia Hex Nipple |
| 207 | 25mm dia Hex Nipple |
| 208 | 32mm dia Hex Nipple |
| 209 | 20mmx15mm dia Reducer |
| 210 | 25mmx20mm dia Reducer Elbow |
| 211 | 32mmx25mm dia Reducer Elbow |
| 212 | 25mmx20mm dia Reducer Tee |
| 213 | 32mmx25mm dia Reducer Tee |
| 214 | Supplying and fixing in position 15mm dia brass SS Elbow Action Tap / SS Heavy Duty Long Body Tap /SS Swan Neck Tap of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary.(Taps should be got approved by the Executive Engineer before use on the works) |
| 215 | 15mm dia brass Elbow action tap |
| 216 | 15mm dia brass Big Cock Long Body |
| 217 | Supplying and fixing in position first quality and approved variety of Gun metal Gate Valve / Wheel Valve with BIS make of the following dia including cost of shellac, thread balls, etc., complete complying with standard specifications (for both internal and external water supply arrangements).The valves to be used on work shall be got approved by the Executive Engineer before use on work. |
| 218 | 50mm dia Gate Value |
| 219 | 40mm dia Gate Value |
| 220 | 32mm dia Gate Value |
| 221 | 25mm dia Gate Value |
| 222 | Supplying and fixing in position White / Colour Special Delux Model Glazed Cascade Type Parryware / Hindware / Equivalent Wall Mounted European Water Closet of best qualityandapprovedmakewith 100mm“P” or“S” trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings, such as, 15mm brass ball valve with polythene float with brass handle, union coupling connected by means of 40mm white PVC flush hand using indian adopter joint including all internal fittings, such as, 15mm bras connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition, etc., complete complying with standard specifications.(The EWC and flushing tank with all accessories should be got approved by the Executive Engineer before use on works) with 10 litres capacity flushing tank with all internaldual flush fittings with normal seat coverWall Fitting |
| 223 | Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with \"P\" or \"S\" trap conforming to BIS with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two sand and Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to CI soil pipes (including the cost of 100mm dia CI pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers.(The water closet should be got approved by the Executive Engineer before use on works). |
| 224 | Supplying and fixing of White Glazed Porcelain Oval Shape Special Type Urinal of size 382 x 398 x 601mm |
| 225 | Supplying and fixing of SS Sink of size 1200 x 550 x 180mm complete as directed by the departmenttal officers. |
| 226 | Supplying and fixing in position best quality approved make White Porcelin Sink of size 600mm x 450mm x 200mm with 32mm dia \"B\" Class G.I. waste water pipe and 32mm dia C.P. waste coupling. with rubber plug and chain, 15mm dia brass nipple including fixing the sink in position and testing for leakages etc., complete complying with standard specifications excluding CI brackets.[The sink and specials should be got approved by the Executive Engineer before use on works] |
| 227 | Supplying and fixing in position best quality and approved make Indian made white / colour glazed earthernware wash hand basin of size 550 x 400mm (without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia \"B\" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works). |
| 228 | Supplying and fixing best quality and make of ready mixed HDPE water storage Water tanks made of PVC materials- including necessary provision for conveying, jointing delivery line, scour pipe, over flow pipe etc., and lifting the tank to the top of the building placing in position etc., complete as directed by the departmental officers.(The plastic water storage tank should be got approved by the Executive Engineer before fixing in position.) |
| 229 | Supplying and erecting in position of following liters capacity Industrial Model Reverse Osmosis Water-cum-Purifier to deliver Potable Water with World Health Organisation (WHO) Standards with following accessories.(a) MS Skid - 1 No.(b) Media 11054 No. Vessel with 20 nb MultiportValve (with Media Pubble and Fine Sand andActivated Carbon Filling) set(c) Feed Pump 0.50 HP – 1 No.(d) Vertical Pump 2-9, 2.00 HP / Single Phase – 1 No.(e) Membrane 40 x 40 filmtech (or) equilaents /Osmonic (USA) - 1 No. and Membrane PressureVessel 40 x 40 -1 No. & Pressure Gauge - 2 Nos.(f) Flow Meter - 1 No. 20” Filter with Housing - 1 No.Low Pressure Switch - 1 No.,Level Switch - 1 No. &Necessary CPVC Pipes and Fittings.The system shall be provide with Two Panel Control System with necessary Stainless Valves and Fittings and Float Control etc. The rate should be inclusive of all civil works, wherever necessary to install the System in position and intact |
| 230 | 50 Liters |
| 231 | 1000 Liters |
| 232 | Supplying and fixing purified water dispenser of size 455mm Length x 450mm width x 1420mm height made up of stainless steel 304 grade sheet of 0.80mm thick and a approximate weight of 65kg. It should consist of 40 litres capacity HDPE storage tank for cold water, 40 litres capacity HDPE storage tank for warm water and a 20 litres capacity HDPE tank for hot water. The rate includes internal pipe arrangements, tap arrangements. It should deliver the warm water, cold water and hot water. The cost includes all materials, transportation to site and fixing charges etc., complete. The make and brand should be got approved by the Executive engineer before use on site and as directed by the departmental officers |
| 233 | Supplying and fixing in position of best quality of Chemical coated Foamcore and underground PVC Soil / waste pipes of various dia having 6 kg / sq.cm. pressure and SN8 KN/m2 with BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications.(The Chemical coated foamcore PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid |
| 234 | 160 mm dia PVC Pipe |
| 235 | 250 mm dia PVC Pipe |
| 236 | 315 mm dia PVC Pipe |
| 237 | Supplying and fixing in position best quality PVC (SWR) pipes Type B various dia and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications.(The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid |
| 238 | 75 mm dia PVC Pipe |
| 239 | 110 mm dia PVC Pipe |
| 240 | Supplying and fixing in position PVC (SWR) specials of ISI mark of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and re-doing the dismantled portion to original condition etc., complete complying with standard specifications. (The PVC specials should be got approved by the Executive Engineer before use on works). |
| 241 | 110mm dia PVC Plain bend |
| 242 | 110mm dia PVC \"Y\" with Single door |
| 243 | 110mm dia PVC \"Y\" with Double door |
| 244 | 110mm dia PVC Cowl |
| 245 | 110mm dia PVC Tee |
| 246 | 75mm dia PVC Plain bend |
| 247 | 75mm dia PVC \"Y\" with Single door |
| 248 | 75mm dia PVC \"Y\" with Double door |
| 249 | 75mm dia PVC Cowl |
| 250 | 75mm dia PVC Tee |
| 251 | Supplying and fixing in position CP Two Way Bib Cock with Health Faucet etc., complete complying with standard specification. |
| 252 | Supplying and fixing Flushing tank of the 10 litre capacity with standard specifications and as directed by the departmental officers. |
| 253 | Supplying and fixing position CI Nahani Trap of size 100 x 75mm with stainless steel gratings with best stainless steel gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of sand and five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three sand) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the CI / PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works) |
| 254 | Supplying and fixing approved best qualityStainless steel 304 grade towel rail 600mm long and 20mm dia pipe.The ends of the pipe is to be bended with required depth and the same is fixled in the wall firmly and the ends are coveredwith stainless steel cupetc., complete complying with standard specifications. (The tower rail should be got approved by Executive Engineer before use on works). |
| 255 | Supplying and fixing in Fabricarion steel Structural supports of using MS Flats 32x6mm and 12x5mm for water supply and waste pipe line etc. including one coat of red oxide primer. |
| 256 | Supplying and fixing in poisition special square type SS Shower rose of size 15 x 15 cm with SS stop cock. including cost of materials conveyance etc., with standard specification. and as diceted by the deaprtmental officers. |
| 257 | Supplying and fixing in poisition 15 mm dia CP Shower Arm with Overhead Shower Rose with ss stop cock. including cost of materials conveyance etc., with standard specification. and as diceted by the deaprtmental officers. |
| 258 | Supplying and fixing in position 150 x 100mm \"P\" or \"S\" stoneware gully trap \"A\" grade with CI double gratings of size 150 x 150mm and 230 x 230mm at bottom and top respectively with necessary earth work excavation laid over a bed of brick jelly cement concrete 1:3:6 (One cement, Three sand and Six broken brick jelly) 150mm thick using 40mm size broken brick jelly including necessary brick work and plastering including dismantling masonry wherever necessary and re-doing the damaged portions to the original conditions using cement concrete 1:3:6 using 20mm stone jelly for fixing the gully trap and giving connections to stoneware sewer line etc., complete complying with standard specifications. [Earth work excavation, brick work, plastering shall be measured and paid separately]. The stoneware gully trap should be got approved by the Executive Engineer before use on works. |
| 259 | supplying and fixing if Fine Polished Granite Slab 1200 x 600 of 18 / 20mm thick thick in all floors for urinal partition including for labour charges for fixing and polishing etc., |
| 260 | Supplying and fixing in position Indian make bevelled edge mirror of approved quality and brand PVC / Fibre Glass framed 600 x 450 x 5.5mm thick mirror, shelf type with hard board backing of approved colour fixed with brass screws, rawl plug, etc., complete complying with standard specification. (The mirror should be got approved by the Executive Engineer before use on woks) |
| 261 | Supplying and fixing best approved best quality Procelain CP soap tray of size 150 x 150 x 50 mm including cost of teak wood plugs, brass screws, etc., complete complying with standard specifications.(The soap tray should be got approved by Executive Engineer before use on works). |
| 262 | Supplying and fixing in positionofSteel Ladder using MS Angle of50 x 50 mm thick for frames and steps. Icluding cutting, granding, welding, and making charges etc., Complete complying with standard specification. And as directed by the depatemetnal officers. |
| 263 | Supply and fixing of Manhole Cover SFRC as per following size including labour and transportation charges etc., complete as directed by the departmenttal officers. |
| 264 | 600 x600mm |
| 265 | 900 x900mm |
| 266 | Medical Gas Line Arrangements : Gas Outlet Points: (Self sealing type - Single / DIN outlet pipe) with \"S\" type bracket made up of copper and the out let of non-interchangeable for other gas. The outlet points are brazed with brass bracket with self sealing valve (Stainless Steel) with all accessories and complete set and are covered by plastic cover duly colour coated as per specific gas and button cover etc., complete as directed by the Departmental Officers and as per IS Code 12827/1989 & ISO 7396/1987 Specification. |
| 267 | Medial Gas Copper Pipeline arrangement to hang on the wall of socket type connection installation of seamless cleaned and degreased non aresenical phosphorous gas copper pipe line with saddles complete with brazing work including all copper fitting (tee, elbow, reducer, coupling) The copper pipelines should be tested suitable for a steam of working pressure of 17.34 kg/ cm2 (17 bar) and confirm to BS 864 Standard with specially made for brazed socket type connection. The medical gas copper pipeline should be tested as per standard and commissioning after painting as per International Code No. IS 2379/1963 Table-V. The pipe lines installed at hte various wings and floors etc., complete as directed by the Departmental Officers as per IS code 12827/1989 & ISO 7396/1987 Specification. |
| 268 | 54mm dia copper pipe ODx1.2mm thick |
| 269 | 42mm dia copper pipe ODx1.2mm thick |
| 270 | 28mm dia copper pipe ODx0.9mm thick |
| 271 | 22mm dia copper pipe ODx0.9mm thick |
| 272 | 15mm dia copper pipe ODx0.9mm thick |
| 273 | 10mm dia copper pipe ODx0.9mm thick |
| 274 | Brass Isolation Valve suitable for the copper pipe and should be of not lubricated 90 degree turn lever ball valve of reputed make, connected in line with medical gas pipe line system by using suitable size brass valve adopter union, ferrule, nipple, rubber \"O\" ring, tapion lap and etc. All pipe line regulators shall be capable of controlling pipe line pressure and must compatible with the requirements specified in IS 12827 /1989. All valves should be pneumatically tested for twice the working pressure for the gas line as per IS Code 12827/1989 & ISO 7396/1987 Specification |
| 275 | 54mm dia ball valve |
| 276 | 42mm dia ball valve |
| 277 | 28mm dia ball valve |
| 278 | 22mm dia ball valve |
| 279 | 15mm dia ball valve |
| 280 | Oxygen Manifold arrangement of 2 banks x 12 cylinder each wing with semi automatic control panel which includes contact gauge 2 No., oulet pressure gauge, brass heavy dut IO x regulator 2 Nos., with suitable adopter, flexible SS Hose. Manifold shall be of a construction and of a designs and material suitable for the service pressure in accordance with IS 12827-1989. Emergency alarms with illuminating display for low/ high pipeline pressure and malfunctioning of system.1) Manifold top frame with provision for connecting 12 cylinders on right bank and 12 cylinder on left bank with high pressure interconnecting tubing, silver brazing, non return for claping 2 x 12 cylinders and related fastener. The O2 manifold should with stand a pressure of 140kg. / CM2 The installation is commissioned after testing as per standards and painted as per International Code and as directed by the Departmental Officers as per IS Code 12827 /1989 & ISO 7396/1987 Specification . |
| 281 | Nitrous Oxide Manifold Arrangements of 2 banks 6Cylinder each wing, withpiston type regulator which includes contact gauge 2 Nos. outlet pressure gauge, brass heavy duty IOX regulator 2 Nos. with suitable adopter, flexible SS hose. Manifold shall be of a construction and of a designs and material suitable for the service pressure in accordance with IS 12827 -1989. Emergency alarams with illuminating display for low / high pipeline pressure and malfunctioning of system. 1) 2x6 cyliner Nitrus Oxide Manifold should be suitable with stand a pressure of 140kg/ Cm2 and above along with high pressure copper annealed tail pipes with end brass adapter suitable for Nitrous Oxide Cyliners and manifold.2) Top frames comprising of high pressure copper pipe of size 12mm ID 1.5mm wall thick with high pressure brass fittings made of high tensile brass and connetions through non -return valves, high pressure copper tail pipes made of high pressure copper pipe size of 7mm ID 1.5mm thick. 3) The disign of middle and bottom frames should be provided to fit both round and flat bottom cylinders safely with fitted heavy duty regualtor. The Manifold should be tested at 3500 pig as per IS 12827/1989 & ISO 7396 / 1987 Specification. |
| 282 | Emergency Oxygen manifold arrangements of 2bankx6cylinder each wing with Piston type regulator which includes contact gauge 2 Nos.,outlet pressure gauge ,brass heavy duty Ioxregulator 2 Nos. with suitable adopter,flexible SS hose.Manifold shall be of a construction and of a designs and matreial suitable for the service pressure in accordance with IS 1282-1989.Emergency alarms with illuminating display for low / high pipe line pressure and malfunctioning of system. 1) Manifold top frame with provision for connecting 2 cylinders on right bank and 3 cylinders on left bank with high pressure interconnecting copper tubing,silver brazing,non return valve,fasteners and cylinder support middle angle frame for claping 6x6cylinders and related fastenders.The O2 manifold should with stand a pressure of 140kg/CM2.The installation is commissioned after testing as per standards and painted as per international code and as directed by the departmental officers as per IS code 12827/1989 &ISO 7396/1987 specification. |
| 283 | Flow Meter made up of Brass with Humidifier Bottle Flow Meter should be back pressure compressed and should be accurate gas flow measurement with control range 0-13 litres per miniute. It should meet strict permission and dumbling standard. The meter body should be made of brass materials. The humidifier bottle should be made of unbreadkable polycorbonate material and auto cleavable at 134 degree centigrate. The includes flow meter and its accessories (silicon tube with mask.) The cost of materials including transport, etc., complete as per standard specification and as directed by the Dpartmental Officer and as per IS 12827/1987 & ISO 7396/1987 |
| 284 | Ward Vaccum Unit with Gauge both mounted on a collection jar of capacity 600 ml and with a wall bracket for mounting it on the wall. The collection jar should be made of unbreadkable polycarbonate materials which is fully auto cleavable at 134 degree centigrade as per standard specification and as directed by the Departmental Officer and as per IS 12827/1989 & ISO 7396/1987 Specification . The rate includes cost of silicon hose with SS nipple on either side. |
| 285 | Theatre Vaccum Unit: The unit should comprise of two reusable 2000ml shatter resistant bottle. Eachmade up of ply carbonate material and fully autoclavable at 134 degree centigrade, should have a vaccum regulator with instant ON/OFF switch and three way left, right or both. All the above itesm should be mounted on atrolleyy having free moving castor wheels. (As per IS12827/1989 & ISO 7396/1987) |
| 286 | Supply, installation,testing and commissioning of equivalent to ingersoll rand reciprocating Air cooled type (10 HP) rating vaccum pump as per following provisions.As per IS 12827/1987&ISO 7396/1987 specificationa) Vacuum pump-10HP-1 Nob) Electric Motor-10HP-1Noc) DOL Starter OLR-1Nod) Vacuum Switch-1Noe) Vacuum gauge-1Nof) Control frame with fittings-1Nog) Suction Scrubber-1Noh) V-Belts-1Noi) G.I & M.S Fittings-1Noj) Brass Fittings-1Nok) Exhaust silencer-1Nol) Base frame for motor and vacuum pump-2Setm) Pilot line with fittings-1Set,Vacuum Room& Air compressor room inside |
| 287 | Supply, installation, testing and commissioning of MS fabricated Vertical Mounted Type 1000 liters capacity Vaccum Receiver with inlet and outlet and drain holes provided suitable to operate with vaccum pump etc as directed by the Departmental Officers. |
| 288 | Supply, installation,testingand commissioning of compressed air system of reciprocating Anestiwata oil Free Air Compressor belt driven type air compressor with following provisions. As per IS 12827/1987&ISO 7396/1987 specification.Compressor package consists of the following:a) 10 HP Air Compressor-1Nob) Electric motor 10HP -1Noc)Dol Starter-L&T-10HP-1Nod) Base frame kid(for motor and compressor)-1Sete)Pressure switch-1 Nof)Pressure Gauge-1 Nog)NRV and Pilot fittings-1Noh)Delivery tube-1 Noi)Foundation bolts&Anchor fasteners-1Noj)Belt Guard-1Nok)Air Drier 50 to 60 cfm capacity-1 No.Drain ball valve-1No,Air outlet ball valve-1No, Vacuum room& Air compressor room insideAccessories: Non-return valves,Air pressure switch,pressure gauge,Isolation valves,Air filters etc., Inter connecting piping:Mild steel pipe of 2\" with fittings. |
| 289 | Supply,installation,testing,and commissioning of MS fabricated vertical mounted type 1000 liters capacity Air receiver with inlet and drain holes provided suitable to operate with vacuum pump,etc., as directed by the departmental officers. |
| 290 | Bed Head Panel of size 1m, length, height 0-0.30cm and depth of 4\". The aluminium powder coated with requirement colour for provisioin points of o2-2 No. Air 1 No. Vaccum 1 No. with double electrical socket with switch 2 Nos. with 2 set with IV - bottle holder fixing to the wall hanging including monitor stand etc., complete. |
| 291 | Equipment for STP: SUPPLY AND INSTALLATION OF RETURN SLUDGE PUMPS CAPACITY; 0.6HP, 3 Phase, MAKE-POINT OR EQUIVALENT, TYPE: SUBMERSIBLE, principle centrifugal, FL class insulation, IP 68 PRODUCTION standard, FLOW RATE: 10000 LITERS/HOUR @ 10 meters head.Delivery pipe, UPVC, schedule 40, 1.5 inches or 40 mm dia, make Supreme or finolex with Union, Non return valve, and other required UPVC fittings from end to end.Electrical cable connection from pump to control panel, cable type armoured cable 1.5 sq,mm, 4 core, with pump side connection and insulation with MRF water proof tape, Cable conduit pipe PVC 4 kg 50mm dia, Control panel side connection with double compression gland, on and off provision in control panel with conductor, relay, MCB, connector and all internal wiring, inside control panel. |
| 292 | SUPPLY AND INSTALLATION OF FILTER FEED PUMPS CAPACITY; 2.0HP, 3 Phase, MAKE-POINT OR EQUIVALENT, TYPE: SUBMERSIBLE, principle Vortex, FL class insulation, IP 68 PRODUCTION standard FLOW RATE: 20000 LITERS/HOUR @ 10 meters head.Delivery pipe, UPVC, schedule 40, 2 inches or 50 mm dia, make Supreme or finolex with Union, Non return valve, Pump Selection UPVC Ball valve and other required UPVC fittings from end to end.Electrical cable connection from pump to control panel, cable type armoured cable 1.5 sq,mm, 4 core, with pump side connection and insulation with MRF water proof tape, Cable conduit pipe PVC 4 kg 50mm dia, Control panel side connection with double compression gland, on and off provision in control panel with conductor, relay, MCB, connector and all internal wiring,connection,inside control panel.Water level controller unit inside control panel, Sensors inside the tank, connection integrated from pump tocontrol panel, sensor cable type 3 core, flexible 1 sq.mm inside conduit pipe. |
| 293 | SUPPLY AND INSTALLATION OF SEWAGE TRANSFER PUMPS CAPACITY; 2.0HP@ 3.P.H, MAKE-POINT OR EQUIVALENT, TYPE: SUBMERSIBLE, principle Vortex, FL class insulation, IP 68 PRODUCTION standard FLOW RATE: 20000 LITERS/HOUR @ 10 meters head. Delivery pipe, UPVC, schedule 40, 2 inches or 50 mm dia, make Supreme or finolex with Union, Non return valve, Pump Selection UPVC Ball valve and other required UPVC fittings from end to end.Electrical cable connection from pump to control panel, cable type armoured cable 1.5 sq,mm, 4 core, with pump side connection and insulation with MRF water proof tape, Cable conduit pipe PVC 4 kg 50mm dia, Control panel side connection with double compression gland, on and off provision in control panel with conductor, relay, MCB, connector and all internal wiring,connection,inside control panel.Water level controller unit inside control panel, Sensors inside the tank, connection integrated from pump to control panel, sensor cable type 3 core, flexible 1 sq.mm inside conduit pipe. |
| 294 | SUPPLY AND INSTALLATION OF AIR BLOWER TYPE;TWIN LOBE, MAKE ; A1 OR EQUIVALENT, CAPACITY; 3 [email protected] P.H WITH CROMPTON MOTORS FOR COLLECTION TANK BLOWER FRAME, SUCTION FILTER, SUCTION AND DISCHARGE SILENCER,NR VALVE, SAFETY VALVE, SET OF V BELT DRIVE. FLOW MEDIA;AIR, 70 CUBIC METER/HOUR, DIRECTION OF FLOW; VERTICAL, PRESSURE; 0.5BAR,RPM-1200 MOTOR FOR AIR BLOWER, MAKE: CROMPTON, CAPACITY 3HP, 3 PHASE, 4POLE, 400/415/440 VOLTS, ALTERNATING CURRENT, SQUIRREL CAGE, TOTALLY ENCLOSED, FAN COOLED (TEFC) BARE SHAFT,INDUCTION MOTOR IN “IE2” ENCLOSURE, RPM-1500.Electrical cable connection from pump to control panel, cable type armoured cable 1.5 sq,mm, 4 core, with motor side connection and insulation with MRF water proof tape, Cable conduit pipe PVC 4 kg 50mm dia, Control panel side connection with double compression gland, on and off provision in control panel with conductor, relay, MCB, connector and all internal wiring,connection,inside control panel.GI air distribution 2 niches pipe make: Zindal, with flanges, and other fittings, with Interlink and arrangements with welding work |
| 295 | SUPPLY AND INSTALLATION OF MOTOR FOR AIR BLOWER, MAKE: CROMPTON OR EQUIVALENT, CAPACITY 7.5 HP, 3 PHASE, 4POLE, 400/415/440 VOLTS, ALTERNATING CURRENT, SQUIRREL CAGE, TOTALLY ENCLOSED, FAN COOLED (TEFC) BARE SHAFT,INDUCTION MOTOR IN “IE2” ENCLOSURE, RPM-1500.Electrical cable connection from pump to control panel, cable type armored cable 6 sq,mm, 4 core, with motor side connection and insulation with MRF water proof tape, Cable conduit pipe PVC 4 kg 50mm dia, Control panel side connection with double compression gland, on and off provision in control panel with conductor, relay, MCB, connector and all internal wiring,connection,Timer control from inside control panel. |
| 296 | SUPPLY AND INSTALLATION OF AIR BLOWER TYPE;TWIN LOBE, MAKE ; A1 OR EQUIVALENT, CAPACITY; 7.5 HP, 3 phase. ACCESSORIES: BASE FRAME, SUCTION FILTER, SUCTION AND DISCHARGE SILENCER,NR VALVE, SAFETY VALVE, SET OF V BELT DRIVE. FLOW MEDIA;AIR, 200 CUBIC METER/HOUR, DIRECTION OF FLOW; VERTICAL, PRESSURE; 0.5BAR,RPM-1200GI air distribution 3 niches pipe make: Zindal, with planges, and other fittings, with Header pipe for Interlink, blower selection butterfly check valve for blower selection and arrangements with welding work. |
| 297 | SUPPLY AND INSTALLATION OF DUEL MEDIA FILTER vessel, Material of construction FRP (fiber reinforced plastics) DIA; 0.6M, HEIGHT 1.50M, Top manhole 300mm for filling the media, Bottom hand hole 100 mm for removing the media with end flanges, inlet and outlet pipe size 2 inches, Air vent and drain vent 1 inches size with end valve. FLOW RATE 25000 LITERS PER HOUR.Multiport valve 2 inches, interlinking pipe, UPVC, schedule 40, 2 inches or 50 mm dia, make Supreme or finolex with Union, Non return valve, Pump Selection UPVC Ball valve and other required UPVC fittings from end to end.Filter Media Silica sand media, pebbles and Activated Carbon media with mesh size and IV value. Will be filled layer by layer in grades. |
| 298 | SUPPLY AND INSTALLATION OF CHLORINE DOSAGE PUMP CAPACITY- 6 liters per hour, with suction and delivery hose, online injector and MAKE; e-Dose OR EQUIVALENT, end to end power supply with 1 sq.mm flexible cable from control panel to dosing pump.Connection in such a way when filter feed pump runs dosing pump will also work in parallel. |
| 299 | SUPPLY AND INSTALLATION OF BARSCREEN;SS MAKE-0.6M*0.6M*0.6M with 1 inch X 1 inch opening. With PVC ropes and retrieving arrangements. This has to be installed in bar screen chamber. |
| 300 | SUPPLY AND INSTALLATION OF coarse bubble disk diffuser 3 inches dia with PVC thread holder and rubber top with 3 mm holes. Inter connecting bruited pressure hose 1 inch dia from header pipe 1 inch isolation valve to diffuser accessories fittings stainless steel Tee. This has to be installed in Collection cum Equalization tank. |
| 301 | SUPPLY AND USE OF BACTRIAL CULTURES FOR STABILISATION |
| 302 | SUPPLY AND INSTALLATION OF TOOLS KIT, SAFETY GLOVES, FIRE EXTINGUISHER ,CHLORINE DOSAGE TANK-50 LTS |
| 303 | SUPPLY AND INSTALLATION OF Fine bubble membrane diffusers 60 MM DIA and 1000 mm length, Make : Techprowith PVC support pipe inside and fine pore membrane housing outside. This has to be installed in SBR TANK. |
| 304 | SUPPLY AND INSTALLATION OF Diffuser accessories MOC STAINLESS STEEL, WILL BE CASTED IN 8 INCHES BY 8 INCHES , 8 INCHES HEIGHT CONCRETE BLOCK. STAINLESS STEEL TEE, PVC ROPE FOR RETRIVING THE DIFFUSER SET. Inter connecting bruited pressure hose 1 inch dia from header pipe 1 inch isolation valve to diffuser accessories fittings stainless steel Tee. This ahs to be installed in SBR TANK. |
| 305 | SUPPLY AND INSTALLATION OF Decanting pumps MAKE- KIRLOSAKAR, 2HP, 3 PHASE, TYPE MONO BLOCK, FLOW RATE 20000 LITERS PER HOURSuction and Delivery pipe, UPVC, schedule 40, 3 inches or 80 mm dia, make Supreme or finolex with Union for pump isolation, PVC 3 inches flop type foot valve, and other required UPVC fittings from end to end, from SBR tank to Filter feed tank. Electrical cable connection from pump to control panel, cable type armoured cable 1.5 sq,mm, 4 core, with pump side connection and insulation with MRF water proof tape, Cable conduit pipe PVC 4 kg 50mm dia, Control panel side connection with double compression gland, on and off provision in control panel with conductor, relay, MCB, connector and all internal wiring,connection,inside control panel.Dry run controller unit inside control panel, Sensors inside the tank, connection integrated from pump tocontrol panel, sensor cable type 3 core, flexible 1 sq.mm inside conduit pipe. |
| 306 | Equipment for ETP : SUPPLY AND INSTALLATION OF Automatic pH neutralizing system with sensors, dosing pumps, dosing tank with all assembly. e-Dose OR EQUIVALENT, dosing pump Model: A-91L(PP)- Max 4 LPH @5.5 Bar – 3 (2Working),100Liters FRP tank (2 Nos tank -1 Acid & 1 Alkaline) pH Sensor (Sensor Acc + -0.1 pH)(1Working+1Stand by)pH Transmitter with 4-20mAController with dual mA output Make: HoneywellDosing Tank and pump mounting arrangement, enclosures, CABLES AND CONTROL PANEL PROVISION. |
| 307 | SUPPLY AND INSTALLATION OF EFFLUENT TRANSFER PUMPS CAPACITY; 1.0HP, 3 Phase, flow rate 10000 liters per hour @ 10 meters head. MAKE-KIRLOSKAR, MONOBLOCK,centrifugal, Delivery pipe, UPVC, schedule 40, 1.5 inches or 40 mm dia, make Supreme or finolex with Union, Non return valve, and other required UPVC fittings from end to end.Electrical cable connection from pump to control panel, cable type armoured cable 1.5 sq,mm, 4 core, with pump side connection and insulation with MRF water proof tape, Cable conduit pipe PVC 4 kg 50mm dia, Control panel side connection with double compression gland, on and off provision in control panel with conductor, relay, MCB, connector and all internal wiring, connection,inside control panel.Water level controller unit inside control panel, Sensors inside the tank, connection integrated from pump tocontrol panel, sensor cable type 3 core, flexible 1 sq.mm inside conduit pipe ANDCONTROL PANEL PROVISION |
| 308 | WITH GENERATOR, CONCENTRATOR, VENTURI, PRESSUE PUMP WITH ALL Assembly.1. Ozone GeneratorMake : Ozone EngType : Corona DischargeOzone Concentration : 50 – 120 gm/m3Dielectric : High barrier quartz tubeInverter : MOSFET based high frequency PWM inverterGive high concentration ozone & high operating lifeFeed gas : Oxygen from PSA oxygen ConcentratorOxygen gas flow rate : 5lpm@90+% purityFeed gas Pressure : 0.5kg/cm2 or 12psiCooling Type : Water cooledCooling water inlet : Ambient TemperatureCooling water flow rate : 0.2m3/h of Normal Potable WaterCooling water outlet temp : 25oc (approx 5c temp. difference)Cooling water pressure : 2kg/cm2 maximumMOC of cabinet : GRP (Glass Reinforced Polyester)MOC of Electrode : SS316L with Quartz Tube and PTFEType of Electrode : Vertical Type with Inside CoolingMOC of all contact part : SS316L and PTFEMOC of Ozone Tube : PTFEType of Transformer : Ferrite Core |
| 309 | SUPPLY AND INSTALLATION OF TREATED EFFLUENT TRANSFER PUMPSCAPACITY; 1.0HP, 3 Phase, flow rate 10000 liters per hour @ 10 meters head. MAKE-KIRLOSKAR, MONOBLOCK,centrifugal, Delivery pipe, UPVC, schedule 40, 1.5 inches or 40 mm dia, make Supreme or finolex with Union, Non return valve, and other required UPVC fittings from end to end.Electrical cable connection from pump to control panel, cable type armoured cable 1.5 sq,mm, 4 core, with pump side connection and insulation with MRF water proof tape, Cable conduit pipe PVC 4 kg 50mm dia, Control panel side connection with double compression gland, on and off provision in control panel with conductor, relay, MCB, connector and all internal wiring,connection,inside control panel.Water level controller unit inside control panel, Sensors inside the tank, connection integrated from pump tocontrol panel, sensor cable type 3 core, flexible 1 sq.mm inside conduit pipe.CABLES AND CONTROL PANEL PROVISION. |
| 310 | SUPPLY AND INSTALLATION OF coarse bubble disk diffuser 3 inches dia with PVC thread holder and rubber top with 3 mm holes. Inter connecting bruited pressure hose 1 inch dia from header pipe 1 inch isolation valve to diffuser accessories fittings stainless steel Tee. This has to be installed in Collection cum Equalization tank.GI air distribution 2 niches pipe make: Zindal, with planges, and other fittings, with Interlink and arrangements with welding work. |
| 311 | SUPPLY AND INSTALLATION TOOLS KIT, SAFETY GLOVES, FIRE EXTINGUISHER ,CHLORINE DOSAGE TANK |
| 312 | Fire fighting Arrangements: Supply and fixing of Fire fighting application oblique type stainless steel Hydrant Valve of size 63mm dia with oblique type instantaneous coupling wht rotating wheel to open and close the valve including MS flange of table \"E\" bolts & nuts with washer as per IS 5290 at ring main around the building and wet riser inside the building including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary etc complete as per standard specification andas directed by the Departmental Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT. |
| 313 | Supply, installation of Fire fighting Application 180 degree swinging type, hose reel drum with 20mm dia braided thermoplastic hose 30 metres long, so as to extend to necessary distance by self rolling spindle wheel including necessary 20 mm dia ball valve and open and close spray nozzie, warm clip, etc.,as per the standard pattern of nay reputed make at every floor nearer to hydrant valve, including conveyance, all incidental charges, necessary scaffolding and re-doiing the dismantled portions to its original condition wherever found necessary., etc complete as per standard specification andas directed by the Departmental Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT. |
| 314 | Supply, and fixing in position of Fire fighting Application Hose of 63mm dia of 15 metres length binded by coppper wire with 63mm dia stainless steel male and female instantaneous fire fighting special coupling as per IS 901 as directed by the Departmental Officers. Near every hydrant points including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition whererver found necessary etc complete as per standard specification andas directed by the Departmental Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT. |
| 315 | Supply, and fixing in position of Fire fighting Application63mm dia stainless steel short length Branch Pipe with hexagonal type spray nozzie of 15mm (or) 20mm jet bore. Near every hydrant points including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition whererver found necessary etc complete as per standard specification andas directed by the Departmental Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT. |
| 316 | Supply of Fire fighting ApplicationApplication MS Hose Box to keep two number of hoses and 1 no. of branch pipe with nozzie having proper glass window type double door with universe open key, painted inside white and outside Post Office Red. Near every hydrant points including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition whererver found necessary etc complete as per standard specification andas directed by the Departmental Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT. |
| 317 | Supply and fixing nominal bore quartized bulb type sprinkler bulb 68 Deg C fast response pendent type including GI coller for each sprinkler bulb, mounted in MS pipe ling using suitable size MS threaded coupling, thread, shellac etc., as per standard mehtods and including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition whererver found necessary etc complete as per standard specification andas directed by the Departmental Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT. |
| 318 | Supply, erection, testing and commissioning of MS ‘C’ Class heavy duty pipe as per IS 1239,to withstand a developing pressure of 10kg/sq.cm including necessary fittings like MS flange of table ‘E ‘ Elbows, reducers, gaskets, both, nuts with washers & Joints as per standard method of arc welding .Including one coat metal primer and two P.O RED painting including conveyance ,all incidental charges ,necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary etc complete as per standard specification and as directed by thedepartmental officers. Make; JINDAL/EQUIVALENT. |
| 319 | 200 mm dia |
| 320 | 150 mm dia |
| 321 | 100 mm dia |
| 322 | 80 mm dia |
| 323 | 50 mm dia |
| 324 | 25 mm dia |
| 325 | Wrapping and coating anti-corrosive treatment for underground 150mm dia MS pipe having one coat of anti-corrosive metal primer ,one layer of Asphalt Tar tape wound over the M.S Pipe as per standard methods as per standard specification as directed by the departmental officers |
| 326 | Supply, erection, testing and commissioning of following sizes heavy duty foot valve including all accessories such as MS flange of table ‘E’ gaskets,bolts&nuts,etc.,installed at end of 150/200 mm dia suction pipeline at sump including conveyance ,all incidental charges ,necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary etc complete as per standard specification and as directed by the departmental officers. Make :NORMEX/KARTAR |
| 327 | 200 mm dia |
| 328 | 100 mm dia |
| 329 | Supply ,erection, testing and commissioning of Cast iron body and bronze internal non-rising spindle sluice valve of sizes at required places to control the flow of water including necessary MS flange of table ‘E’ gaskets , bolts & nuts including conveyance all incidental charges ,necessary scaffolding and re-doing the dismantled portions to its original condition whereverfound necessary etc complete as per standard specification and as directed by the departmental officers.Make:NORMEX/KARTAR |
| 330 | 150 mm dia |
| 331 | 100 mm dia |
| 332 | Supply, erection, testing and commissioning of Cast iron body and Gun metal or stainless steel internal Non-return valve of following sizes to control one way flow ofwater to be installed pump room at delivery line and near overhead, tank at terrace level near to jockey pump and motor including necessary MS flange oftable ‘E’, gaskets, bolts & nuts, etc. as per IS 5312. including conveyance, all incidental charges, necessary scaffolding and re-doing dismantled portions to its original condition wherever found necessary etc complete as per standard specification and as directed by the departmental officers. |
| 333 | 150 mm dia |
| 334 | 100 mm dia |
| 335 | Supply, erection, testing and commissioning of Gun metal Gate valve of size 50mm dia including necessary MS flange of table ‘E’ gaskets, blots & nuts, etc. installed at pump house delivery line for the purpose ofpriming water to suction lineincluding conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary etc complete as per standard specification and as directed by the departmental officers. Make:LEADER/EQUIVALENT.50 mm dia (Pump room, All Floor Sprinkler branch – 1stfloorto 6th Floor) |
| 336 | Supply, erection, testing and commissioning ofGun metal non-return valve ofsize 50mm dia including necessary MS flange of table ‘E’ gaskets, bolts & nuts, etc., installed at pump house delivery line for the purpose ofpriming to suction line so that to control one way including conveying, fixing and incidental charges etc complete as per standard specification and as directed by the departmental officers, Make: LEADER/ EQUIVALENT |
| 337 | Supply and providing 1000 Litres capacity priming tank made up of PVC Make: SINTEX/EQUIVALENT |
| 338 | priming tank mounted with the supporting arrangement fabricated using MS angle for the height of 3.00 mtrs from the floor level, inlet, outlet, and drain arrangements inside the fire fighting pump room as directed by the department officers |
| 339 | Supply and laying of following sizes of armoured Aluminium/Copper cables for electrical motor. control Panel, Pressure switch, jockeymotor etc. all incidental charges necessary scaffoldingand re-doing the dismantled portions to its original condition wherever found necessary etc.Make.POLYCAB/PARACON/FINLOEX/EQUIVALENT |
| 340 | 3 cores 185sqmm armoured aluminium cable |
| 341 | 3 core 10 sqmmarmoured copper cable |
| 342 | 2 core 2.5 sqmm armoured copper cable |
| 343 | Earthing arrangements with GI earth plate including charcoal and salt with necessary excavation in all soils and to full depth as may be required and masonry work. Refilling the sides of foundation with excavated earth as per the standard specification and as directedby the department officers. |
| 344 | Supply, erection, testing and commissioning of pressure Gauge with 0 to 141 kg range of reputed make with necessary value, milling thread Ms coupling fixed at delivery pipe line in pump house to read the developing pressure including conveyance. All incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary etc. complete as per standard specification and as directed by the departmental officers. Make: H-GURU/ISIMARK/EQUIVALENT. |
| 345 | Supply, erection, testing and commissioning of suitable Pressure switch of reputed make line indfoss or Donfoss including necessary values, couplings etc. connected with electrical main control panel and setup at proper differential so as to auto start& auto stopthe electrical motor. Jokey motor including conveyance. all incidentalcharges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary metering protections & indications completeas per standard specification and as directed by the departmental officers. Make: DONFOSS/INFOSS/ISIMARK/EQUIVALENT. |
| 346 | Supplying, installation, testing and commissioning offirefightingelectricalcontrolpanelofcubical constructionfloormountedtypefabricatedusing CRCAsheet,compartmentalisedwithhinged lockable door dust, and internal wiring, earth terminals,numberings,necessary metering protections&indicationscompleteinallrespect. Suitable for operation on 451 volt. 3phase,50Hz AC supplywith enclosureprotectionclassIP54and mounted with the followings: A: Common panel in firepumpHouse(i)incomera)1no600A TP&nsdfuwithHRCfusesb)1setof600A,4bar Aluminiumbusbar,415V,50HZAcsupplyc)1No (0-500A)digitalammeterwithselectorswitch& CT’sd)1no(0-500V)digitalvoltmeterwith selector switch &control fuses e)3 nos. phase indication lamp LED type with toggle switches with control fuses 1.400 A TPN SDFU with suitable HPfullyautomaticstar/Deltastartedoverload protection , Digital ammeter with built in selector switch and suitable CTs, current sensing typesingle phasingpreventercompletewithallaccessories aandinternalwiringrequiredforautomatic operation.Selectorswitchforauto/manual/OFF operation-1No(b)Jockeypump2.125ATPN SDFU with HRC fuses with suitable Hp fully |
| 347 | Supply, erection, testing and commissioning of fire fighting electrical control panel of 15 HP , 415 V, 50 Hz rating wall mounted type fabricated using CRCA sheet, with hinged lockable door, dust, and vermin proof with following provisions. a) 63 Amps, 4 pole mcb – incomer, 6 Amps, 2 pole MCB for control circuit – 1 set. b) R,Y,B phase indication lamp, voltmeter(0-500V) Ammeter (0-50A) , Voltmeter Selector switch – 1 set c) 32 Amps power contactor with 230V coil, 14-23 Amps overload relay – 1 set e) Indication lamp for motor ON/OFF/TRIP – 1 set f) AUTO / MANUAL selector switch, ON/OFF push button – 1 set g) Add on block, Terminal Block, power wiring, control wiring, cable lugs, slotted cable cover. The above panel mounted on wall using anchor fasteners bolts, plugs, incoming and outgoing cable connection and all works carried our as per standard methods and as directed by the departmental officers. |
| 348 | Supply erection testing and commissioning offire fighting application horizontal centrifugal type pump rated for 2280 LPM at 70 mtrs head with electrical motor of 60 HP of 415V, 3 phase connection, complete with base plate and accessories. |
| 349 | Supply, Installation, Testing and commissioning ofDiesel engine driven main Fire Pump suitable for automatic operation and consisting offollowing complete in all respects as required (a)1 No. Horizontal split Casing centrifugal type fire pump capable ofdelivering2850LPM against a total head of110 mtrs so as toensureaminimum pressure of3.5Kgper sq cm at thefarthesttop most hydrant/ Outlet with pump casing of cast iron togradeFG 200,IS210-1978 and parts like Impeller, shaftsleeve, bearing ring etc of noncorrosivemetal either like Bronze, brass orGunMetalandshaftstainless steel. b) 100 BHP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant BS & IS standard complete. c)Auto starting mechanism, 12 volts 24 voltselectricstarting equipmentlikeselfMotor, Dynamo, Solenoidswitches etc. d)110 ltrs capacity Dieseltank mounted over stand fabricated using 25mmx25mmx6mm size MS angle, providing with levelindicator, inlet port, outlet port, drain port and diesel return line port and fuel pre filter, after filter etc. |
| 350 | Supply erection, testing and commissioning of 180 LPM, 70 metres, Head Pressurization Pump with 10 HP electrical motor of Kirloskar make with suitable base frame incluidng necessary vibration bad mounting etc.,m including conveying, fixing and incidental charges, etc., complete as per standard specification and as directed by the Departmental Officers. Make : KIRLOSKAR / EQUIVALENT. |
| 351 | Supply, erection, testing and commissioning of fire fighting application Monoblock Motor Pumpset of 900 LPM at 40 metres head to develop 3.5kg / sq.cm at the heighest and farthest hydrant point to make 30m water jet at the time of fire fighting emergency circumstances, coupled with 15KW / 20HP rated three phase 414 volts, 50 HZ, 2880 rpm electrical motor the pump with cast iron body, bronze impeller, rope gland packaging, suction size of 100mm dia, delivery size of 80 mm dia, including the cost of foundation concrete, anti-vibration mounting, rain safety hood and etc., complete as directed by the Departmental Officers. (Make: Kirloskar KDS 2050 + or Equivalent) |
| 352 | Supply, erection, testing and commissioning of Fire fighting 4 way fire brigade inlet with necessary Gun metal 63 mm dia non return spring shutter arrangements so that to control one way flow at the time of emergency water supply by fire and rescue service fire engine entry, including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary etc complete as per standard specification and as directed by the departmental officers.Make : KIARTAR/OMEX/ EQUIVALENT |
| 353 | Supply, erection , testing and commissioning ofAir release valve of20mm dia so as to release airlock in100mm dia MS pipe at top most wet riser, including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary etc complete as per standard specification and as directed by the departmental officers. Make: KARTAR/ EQUIVALENT. |
| 354 | Supply and fixing ofstored pressure ABC (Mono Ammonium Phospate) powder type Fire Extinguisher of6 kgs capacity as per IS: 15683 with pressure gauge, discharge hose &control nozzle, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary etc complete as per standard specification and as directed by the departmental officers. Make: EXCELLENT/SAFETY FIRST/ EQUIVALENT |
| 355 | Supply and fixing ofcarbon-di-oxide Gas type 2 kg capacity Fire Extinguisher as per New IS No. 15683 complete with with control valve, discharge hose with horn, wall mounting bracket, safety clip etc., Including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantledportions to its original condition wherever found necessary etc complete as per standard specification and as directed by the departmental officers.EXCELLENT/SAFETY FIRST/EQUIVALENT |
| 356 | Supply and fixing of pre-fabricated steel structural materials using MS angle, channel, plate and similar sections for supporting suction and delivery pipe and manifold of fire pumps. The quoted rate shall includes necessary bolt, nut etc. and one coat of primer and synthetic enamel painting of approved shade and as directed by departmental officers. |
| 357 | 100mm |
| 358 | 80mm |
| 359 | 50mm |
| 360 | 40mm |
| 361 | Supply, Installation, testing and commissioning of Microprocessor based conventional 12 zone fire alarm control panel having the rating of 24 Vot DC power supply, consisting 230/24 volt SMPS unit, 2 Nos 12 Volt 7 AH stand by batteries, suitably mounted on wall using fixing accessories like screws, plug, clamps and etc., as per standard methods and as directed by the departmental officers. |
| 362 | Supplying, installing, testing and commissioning of conventional Smoke Detector with base and asdirected by departmental officers. |
| 363 | Supplying, installing, testing and commissioning of conventional Electronic Hooter with base and asdirected by departmental officers. |
| 364 | Supplying, installing, testing and commissioning of conventional Manual Call Point with base and asdirected by departmental officers. |
| 365 | Supply and laying of FRLS PVC insulated 2 core 1.5 sq.mm Armoured Copper Cable on ceiling / wall using fixing accessories likescrews, plug, clamps and etc., as per standard methods and as directed by the Departmental Officers. |
| 366 | Wiring with 2 x1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigidpipe Concealed inwall and ceiling with PVC accessories with Module GIswitch box in flush with wallwith 6A one way module switch with module front plateand making good of the concealed portion with suitable colourforConcealedPVC Light point / fan point (for electronic regulator) (5 points / Coil) Higher End ) (DATA 1) |
| 367 | Wiring with 2 x1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (6 points / Coil) Higher End (DATA 2) |
| 368 | Wiring with 3 x1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A two way module switch with module front plateand making good of the concealed portion with suitable colour for Concealed PVC pipe Stair case Light point Higher End. (DATA 3) |
| 369 | Supply and fixing of 1no.6A two module 5pin socket, 1no. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI) in flush with wall with connections.Higher End (SD-464) |
| 370 | Supply and fixing of 7W/9W LED Lamp for BH point.(DATA-4) |
| 371 | Supply and fixing of 4\"20W LED Tube light fitting with Batten (Make : Higher End)with TW round blocks on wall or ceiling with LED tube with PVC unsheathed Copper leads from terminals to the fitting.(DATA-5) |
| 372 | Supply and fixing of 24W LED 2x2 square type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting.(SD-526) |
| 373 | Supply and fixing of 18W LED square type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting.(SD-528) |
| 374 | Supply and fixing of 1200mm (48\") sweep AC ceiling fan (High speed) complete (Higher end) with 2module 100W fan step regulator (Higher end) with 1 metre down rod on the existing fan clamp .(DATA - 6) |
| 375 | Supplyand fixing of 300mm (12\")sweep (light duty) AC exhaust fan complete without providing of hole in the wall [SD-115] |
| 376 | Supply and fixing of louvers shutters arrangements for 300mm (12\") sweep (light duty) AC exhaust fan.[SD-120] |
| 377 | Supply & Fixing of AC / DC 76mm Buzzer /call bell suitable for 230 Volts 50 c/s single phase AC supply on suitable TW Board with push switch.(SD 105) |
| 378 | supply and fixing of 48W LED street light fitting with LED (Higher end) with 32mm dia GI pipe (class B) with 1no. 32mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting.(SD-535) |
| 379 | Supply and fixing of WT bulk head fitting with guard suitable for 9W LED lamp with LED lamp .(DATA-7) |
| 380 | Supply and fixing of 3nos. 6A two module 5pin socket, 3nos. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI) in flush with wall with connections. Higher End.(SD-476) |
| 381 | Supply and fixing of 1no. 6/16A two module socket, 1no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI) in flush with wall with connections. Higher End (SD-488) |
| 382 | Supply and fixing of 3Nos. 6A 5 pin universal socket 2 module, 1 No 16A 5 pin universal socket 2 module with 3Nos 6A 1way SP 1moduleswitch and 1No 16A 1way SP 1moduleswitchconcealed in suitablemodule metal flush type box (GI) covered withmodule white cover plate with frame (Plastic) (Higher End ) in flush with wall with earth connection.(In ICU Ward) (SD-524) |
| 383 | Supply and fixing of 20Amps DP plug and socket in sheet steel enclosure with 32A DP MCB in flush with wall with earth connection.[for AC Plug] [SD-140] [For AC unit] |
| 384 | Supply and fixing of 8way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1no. 32A DP MCB switch as incoming and 6nos. 6A to 32A SP MCB as outgoing in flush withwall with earth connection only. Higher End.(SD-601) |
| 385 | Supply and fixing of 12way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1no. 40A DP MCB switch as incoming and 10nos. 6A to 32A SP MCB as outgoing in flush withwall with earth connection only. Higher End (DATA -8) |
| 386 | Supply and fixing of 12way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1no. 32 A DP MCB switch as incoming and 10 nos 6A to 32A SP MCB as outgoing in flush with wall with earth connection onlyHigher End(SD-613) |
| 387 | Supply and fixing of vertical type 4 way triple pole neutral MCCB DBin sheet steel enclosuredouble doormetal cover with IP 43 protection with 1No. 125AFP MCCB as incoming and 4Nos. 63A TP MCB as outgoing with suitablr cable andbox in flush with wall and making good of the concealed portion with earth connection.Higher end(DATA-9) |
| 388 | Supply and fixing of vertical type 4 way triple pole neutral MCB DBin sheet steel enclosuredouble doormetal cover with IP 42 protection with 1No. 63AFP MCB as incoming and 2Nos. 32A TP MCB and 6 nos 32 A sp MCB as outgoing with suitable cable box in flush with wall and making good of the concealed portion with earth connection.Higher end (DATA-10) |
| 389 | Supply and fixing of 7segment 4way TPN MCB sheet steel distribution board (Higher end) with metal/ acrylic door cover flush type/ surface type fitted with busbars and neutral links with single/ three phase MCB outgoings and seperate 4way provision for accomodating one no. 4pole incoming MCB/ Isolator and another seperate 4way provision for accomodating one no. 4 pole ELCB/ RCD (totally 8 ways in one segment) (3x 4 ways in each segment) and seperate provision for MCB/ Isolators (totally 12nos) 63A 4P MCB - 1 no, 63A 4P 30MA RCCB/ELCB - 1 no,63A DP MCB -3 nos, 6A to 32A SP MCB - 12 nos . for sub incomers in 3segments with lable holder and provison for taking up cable for size not less than 35sq.mm. with the following in flush with wall with earth connection only.(SD-714) (For Lighthing Each Floor) |
| 390 | Supply and fixing of 7segment 6way TPN MCB sheet steel distribution board (Higher end) with metal/ acrylic door cover flush type/ surface type fitted with busbars and neutral links with single/ three phase MCB outgoings and seperate 4way provision for accomodating one no. 4pole incoming MCB / Isolator and another seperate 4way provision for accomodating one no. 4pole ELCB/ RCD (totally 8 ways in one segment) (3x 6ways in each segment) and seperate provision for MCB/ Isolators (totally 18nos) 63A 4P MCB - 1 no, 63A 4P 30MA RCCB/ELCB - 1 no, 63A DP MCB -3 nos, 6A to 32A SP MCB - 18nos for sub incomers in 3segments with lable holder and provison for taking up cable for size not less than 35 sq.mm. with the following in flush with wall with earth connection only.(SD-715) |
| 391 | Supply and run of 2 of 1.5 sqmm (22/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V Grade in suitable PVC rigid pipe concealed in wall and ceiling and making good of the concealed portion with suitable colour. (for ups wiring) ) [DATA-11] |
| 392 | Supply and Run of 2 of 2.5 sq.mm. (36/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour. [For 3x6A Computer Plug, UPS Line] (SD- 414) |
| 393 | Supply and run of 2 of 4 sqmm (56/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V Grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14SWG TC wire and making good of the concealed portion with suitable colour.[SD-57] [For 8W SPNMCB DB,20A MC Plug,Socket 16A Power Plug and Set Plugs] SD-57 |
| 394 | Supply and run of 2 of 6 sqmm (84/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V Grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14SWG TC wire and making good of the concealed portion with suitable colour.[SD-59] [For 12W SPNMCB DB] SD-59 |
| 395 | Supply and run of 4 of 6 sqmm (84/0.3) PVC insulated SC unsheathed Cu. Conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour. [SD-63] (For 32A TPN Mains and MCBs) SD-63 |
| 396 | Supply and run of 4 of 10 sq.mm. (140/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14 SWG TC wire with painting of suitable colour. (63A MCB Enclosures for ACs) (SD-424) |
| 397 | Supply and run of 4 of 16 sq. mm (101/0.45) PVC insulated S.C unsheathed Cu. Conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour.(6W / 4W 7S TPNMCB DBs, Lift Mains and Xray, Mammography, Fluoroscopy, Gamma X ray 63A Mains)(DATA-12) |
| 398 | Supply and run of 4 of 25 sq. mm (168/0.45) PVC insulated S.C unsheathed Cu. Conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour.(DATA-13) (For 125A V TPN DB ) |
| 399 | Supply and fixing of 32A TPNMC switch on suitable angle iron frame work with MS cable entry box with earth connection only.(For Lab) (SD-164) |
| 400 | Supply and fixing of 63A TPNMC switch on suitable angle iron frame work with MS cable entry box with earth connection only. (SD-166) (For 6Nos Lift Control Switch, and 2Nos Pump set) SD-166 |
| 401 | Supply and fixing of 32A FP MCB in Metal box FP enclosure in flush with wall and making good of the concealed portion with earth connection. (Higher End make) (Autoclave,CSSD Machines)(DATA-14) |
| 402 | Supply and Fixing of 16A Two-way switch in suitable Modular flush type GI box on wall with suitable front cover plate with earth connection (Higher End)(For Lift well lighting Control) (DATA-15) |
| 403 | Supply and run of 3 of 2.5 sqmm (36/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V Grade in suitable heavy gauge MS conduitpipe on wall and ceiling with continuous earth wire connection of 14SWG TC wire with painting of suitable colour. (For Lift Well Light Control) (DATA-16) |
| 404 | Supply and fixing of 8 way single pole and neutral MCBDB with metal door cover with IP 42 protection with 1No. 32 Amps DP MCB as incoming and 2 Nos. 10A SP MCB and 2 Nos. 10A DP MCB outgoing in flush with wall and making good of the concealed portion with earth connection only. The MCB DB and MCB\"s should be with ISI mark(and of Higher End make) (For 6Nos Lift Room Lighting Control) (DATA-17) |
| 405 | Supply and fixing of 63A FP MCB with 63A 30mA FP ELCB in 8 module weather proof enclosure in flush with wall and making good of the concealed portion with earth connection(Higher end).(For 6Nos Lift Room Control , 5Nos OT AC Units and 2Nos Green Zone, Red Zone AC Units) (DATA- 18) |
| 406 | Supply and fixing of 200A TPN sheet steel double break switch with HRC fuse and Neutral on suitable angle iron frame work with MS cable entry box with earth connection only. (SD-171) (In Fire Pump,CT scan & MRI) |
| 407 | Supply ,installation , testing and commissioning of 11TR factory assembled double skin AHU with 100mm -45kg/cum PUF Insulated detachable panels ,extruded thermal break aluminium profiles filled with PUF,panel external skin with 0.6 mm preplasticized sheet, panel internal skin with 0.6mm galvanized sheet, AMCA tested DIDW backward/ forward curved centrifugal fan with EFF1 rating motor, drive arrangement with taper lock pulleys for fan and motor, vibration isolators out of heavy duty rubberized mounts, prefilters with 3ply HDPE 50mm thick filters having an efficiency of 90% 10 Micron and 5 Micron, 6row /12FPI deep DX copper cooling coil with copper header and aluminium fins, GI mist arrestor, condensate coil trough with SS-304-20G insulated with 9mm closed cell elastomeric foam,guard for inspection door, out let damper of aerofoil blades & PVC gears, and flexible fire retardant canvas complete with galvanized hardware. Each of the cooling coils will have independent distributers, electronic expansion valve kit, catch all drier, independent DX coil circuit to connectivity to each ODU circuit. Appropriate devices to be installed to monitor the Temperature, Humidity and Diff. Pressure inside the Operation Theatre. (Carrier/ Voltas/ Bluestar make/ Equ.) (MR) |
| 408 | Design ,supply , installation, testing and commissioning of DX 11TR nominal capacity factory assembled Air-cooled Condensing unit fixed with energy efficient scroll compressor along with grooved copper tube/aluminium fins air cooled condenser coil with anti corrosion coatings,liquid ,accumulator, low noise alumimium propeller condenser fan with Fan motor etc all suitably assembled neatly in heavy duty GSS sheet metal cabinet and duly powder coated as per specification .the unit to include built in safety controls like HP/LP switch power quality protector ,in built thermal / temperature protection. (carrier make) (MR) |
| 409 | Supply and fixing of Laminar Air flowPlenum for SS304 - 1.0 mm Thick casing, Mini Pleat Hepa Filters for 100mm Thick- Flange type, OT Pendant Light provision for 600X600, With SS304-1.2mm Thick perforated sheet. PLENUM SIZE: 1800L X 2400W X 350H.High Efficiency particulate Air (HEPA) filter specification:Filter Size : 8 feet x 6 feet x 1 feetClassification : H-13Construction :Panel TypeEfficiency :99.97% Optical efficiency at .3 micronCleanliness level: Class 100 As per NABH StandardSpacers: Aluminium. Initial pressure drop:25 mm W.CFinalpressure drop : 75 mm W.CDuct holding capacity:4750gm/Sq.mtrFraming :Aluminium (Box type)Washable : No. Test reports to be furnished from approved Government External Quality Assurance Lab/ Agency to meet the testing parameters after commissioning of the AC system with HEPA filter as per NABH standards. (MR) |
| 410 | A) Supply, Installation, Testing, Commissioning and Handing over of 5.5 TR Capacity ceiling suspended ductable Air conditioner high tech, low height, low noise level indoor unit with fin and tube type cooling coil, Detachable type drier provided in refrigerant circuit to reduce moisture content multi-stage type distributor for feeding equal quantities of the refrigerant mixture to all the section of the coil with required valves, directly coupled blower to reduce troubles and wear & tear compared to drive blower. Thermostatic expansion valve lift and pull type aluminium framed durable, washable air filter. Integrated electrical panel with complete microprocessor control with display for easy operation and maintenance of unit common operating conditoners of 45 F suction temperature. Auto reset type HP/LP safety cut to improve relaibility of compressor.B) 5.5 TR capacity ceiling suspended ductable air conditioner high tech outdoor unit with power saving high efficiency sturdy and rugged 1 No. of scroll compressor each with in-built internal thermal protector, internal pressure relief valve, Auto reset type HP/LP safety cut out to improve reliability of compressor and condenser shall be made of super slit high efficient aluminium fins mechanically bonded to copper tubes condenser \"L\"type coil to be rigidly fixed to unit frame with fasteners, imported condenser fan & fan blades to be statically and dynamically balanced to reduce noise and vibration. The fans are direct driven 3 phase motor with protection. Condensing temperature 130deg.F for the system operations. (SR) |
| 411 | Supply and filling of non-CFC Refrigerant Gas. (SR XIV part N 5 M-2046 ) |
| 412 | Supply & fixing of hard drawn copper Refrigerant piping of suction line of Size 7/8” inches with necessary fitting and clamp etc…(SR XIV part N 3 M -2003 ) |
| 413 | Supply & fixing of hard drawn copper Refrigerant piping of liquid line of size 5/8” inches with necessary fitting and clamp etc…(SR XIV part N -1- M-1990) |
| 414 | Supply and fixing of flexible canvas connection between indoor unit and ducting and rubber pads, with ceiling Support angle rods etc... (SR XIV part N -3- M-2004) |
| 415 | Supply and fixing of 50mm thick anti vibrating rubber pads (SR XIV part N -3- M-2005) |
| 416 | Supply, Fabrication and Installation of 22 G Sheet GI Ducting for both suction and Return arrangement insulate with for Operation Theatres with inter linking arrangements with necessary angle supports, anchor fasteners and threaded rods etc... as required. (SR XIV part N -3- M-2007 ) |
| 417 | Supply, Fabrication and Installation of 24 G Sheet GI Ducting for both suction and Return arrangement insulate with for Operation Theatres with inter linking arrangements with necessary angle supports, anchor fasteners and threaded rods etc... as required. (SR XIV part N -3- M-2006 ) |
| 418 | Supply and Providing Thermal Insulation of 9mm thick vidoflex with aluminium foil.(SR XIV part N -3- M-2016) |
| 419 | Supply and fixing of powder coated Extruded aluminium powder coated supply and returnair grilles/diffuser withvolume control damper .(SR XIV part N -3- M-2009 ) |
| 420 | Supply, fabrication and fixing of duct mouth dampers.(SR XIV part N -3- M-2014 ) |
| 421 | Supply and fixing of 1 inch PVC water drain pipe line on wall with suitable Clamp as required.(SR XIV part N -3- M-2010 ) |
| 422 | Supply, fabrication and fixing of suitable MS angle support frame formounting the out door Units.(SR XIV part N -3- M-2012 ) |
| 423 | Supply, fabrication and fixing of suitable MS angle support frame formounting the in door Units.(SR XIV part N -3- M-2011 ) |
| 424 | Supply and providing civil concrete block for mounting the air coditioning unit (SR XIV part N -3- M-2017 ) |
| 425 | Supply and providing of pipeline nitrile rubber insulation forRefrigerant and drain pipeline. (SR XIV part N -3- M-2013 ) |
| 426 | Supply and providing accoustic for initial portion of ducting with 12mm thick fibre glassrigid board covered with tissue paper and Aluminium perforted sheet (SR XIV Part N 3 M-2015) |
| 427 | Supply and fixing of microvee filter 600x600mm size fine microvee mesh filter with efficiency of 5 micron level for return air. [MR] |
| 428 | Supply, fabrication and fixing of Fresh air Louver made of extruded aluminium with bird screen provided with intake louvers. [MR] |
| 429 | Sand cement plastering (1:3) of 20mm thickness with chicken mesh for external exposed portion of duct (MR ) |
| 430 | Supply erection testing commissioning of 2.00TR (6000 KCal/Hr) ABS Plastic split type Air Conditioner conforming to IS1391[Part 2] 1992 with Rotary compressor operating on Non CFC refrigerantsuitable for wall mounting for operating on 230V 50HZ single phase AC supply withFive star rating Model as per BEE Specification and capable of performing the following functions. A) Cooling, B) dehumidifying C) Air circulating D) Filtering the installation work for the above split type AC units includes the following.1. Mounting /fitting indoor and outdoor units at their respective locations. 2. Laying refrigerant pipe line of 6mtrs distance and connectingboth units after drilling hole in the wall if required thickness of the copper tubing shall not be less than 0.80mm 3. Insulating the suction pipe with expanded polythene foam 5mm thick tubing.4. Laying 15mm dia flexible PVC drain pipe of 6mtrs length to throw out the condensate water being formed in the indoor unit.5. Leak testing the entire gas unit.6. Charging refrigerant gas in the unit. 7. suitable electric wiring to be provided with 2.5sq.mm PVC insulated copper wire between indoor and outdoor units up to 4mtrs length and up to switch within 3mtrs of location of indoor unit.(Make -Carrier/voltas /Blue star make only) [SR] |
| 431 | Supply and fixing of 5KVA Automatic voltage stabilizer of wall mounting type with Automatic time delay switching arrangements suitable to operate on 230V Single phase supply. [SR] |
| 432 | Supply and laying of 5/8\"\" and 3/8\"\" copper pipe (Extra beyond 3Mtrs supplied with AC Unit) (SR) |
| 433 | Supply and fixing of MS Stand for fixing outdoor unit.(SR) |
| 434 | Supply and erection of Double pole 11 KV H.TStructure of 33 feet 200 x 100x5.7mm R.S Joist with 10 feet centre to centre on either side with necessary MS angles ,cross branching and mass concreting of poles to received the 11 KV supply with following HT accessories complete as per Central Electricity Authority (measures relating to safty and electric supply ) regulation a) 2Nos, 33 feet length, 200x100x5.7mm R.S Joist poles and base plate of 300x300x6mm with concreting and coping.b) One set of 3Nos 11KV lighting arrester to be mounted on suitable channel iron frame work of size4”x2”x1/2” complete.c) Three sets of 3 Nos. 11 KV pin insulator fixed on suitable channel iron framework complete for supporting copper jumper.d) One set of 3 Nos. 11 KV DO fuses complete with insulator on channel iron support.e) Two nos. of stay arrangements with guystrain/shackleinsulators with necessary masonry work .f) Supply and fixing of required cross bracing made of size 2 ½\"x 2 ½\"x ¼ “ MS angle to keep the structure balance.g) Providing H.T connections and jumper connections from supply point to the 2 pole structure with ACSR conductor / AeroHDBC conductor for giving necessary connections and jumpering from 11 KV strain Disc insulators to AB switch, AB switch to lightningarrestor, andDO fuse through insulators,and G Fuse to post top insulators and pin insulators complete with colour coding. h) Supply and fixing of 2 Nos. 11 KV metal danger boards.i) Painting the structure complete with primary coat of red oxide and two coats of alu. paints.j) Fencing:supply and Fixing of fencing with 10 SWG GI chain link fencingof size 10mm x 10mm, 10 SWG lacingwith MS post of size of 50mmX50mm withsuitable channel/ stiffeners at the top of the chain linked fencing provided around the TANGEDCO\"s DP structure yard and the SS yard at point ofsupply and the lacings fastened to the top channelcomplete structurewith paintingwith a primary coat of red oxide and two coatsof good quality aluminium paint and etc as directed by the departmental site officers.(As per SR) |
| 435 | Supply, erection, testing and commissioning of 1000 KVA, 11KV, 433V, HV - Delta, LV Star off load tap changing, copper wound, outdoor type, distribution Transformer as per IS 1180(Level II) ON AN cooled, confirming to relevant IS 1180 / IEC 60076, Level-II Class A Insulation and mounted on 300 x 90 x 6mm base channel bolted to a suitable RCC plinth of height 5\" and RCC foundation to a depth of 2\" with reinforcement by suitable MS rods 150Kg / m3 capable of bearing 2 ton weight and connected works fitted with the following:1) HT Cable End box suitable for connection of 11KV 3c x 240 sq.mm HT cables & LT Cable end box suitable for connecting 1600A Bus duct2) Bucuholz relay with shut off valve, alarm and trip contacts.3) Dehydrating silica gel breather.4) Conservator with oil filling pipe, cap and drain plug valve.5) Tank drain cum bottom filter valve with plug.6) 4 Nos. plain rollers uni and bi-directional under base channels with skid.7) Dial type thermometer with pocket to measure oil temperature stem type.8) Tank top filter valve with plug.9) Explosion vent with diaphragm.10) Oil level gauge with marking.11) Two body earthing terminal and additional neutral bushings for solid earthing.12 Rating and terminal marking diagram plate.13) Lifting hooks/ Lifting eyes/ Jacking pad to facilitate easy movement of Transformer to ground level, cover lifting lugs.14) Off load hand operated tap changing switch at standby height from ground level.15) Tapping on primary winding for voltage variation +5% to -5% in steps of 2.5%.16) Welded and detachable radiators.17) Air release device.18) The transformer should be supplied with first filling of oil as per IS 335 with high dielectric strength, BDV and flash point.19) Monogram plate.20) Shut off valve for surge relay21) Oil surge relay22) All removable covers shall be provided with weather proof hot oil resistant, resistance gaskets to prevent leakage of water into core, and oil from the tank with low no load loss 1100W and full load loss 6400W, impendence 5% with temperature rise oil / winding 50° - 55°C(Make: CREL / Rowsons/SPS or its equivalent)(SR) |
| 436 | Design, Supply, Erection, Testing & Commissioning of sheet steel enclosed, Dust & Vermin proof, 1600A Single tier MV ACB Floor mounting cubicle panel made up of 1.6mm CRCA sheet steel with powder coating, segration of incoming & outgoing feeders should be with necessary clearence to terminate the outgoing cables with suitable capacity, necessary SMC.E.B Incoming: 1600A FP 50 KA micro proccesor basedEDO ACB, shunt & UV Release - 1no, E.B. Incoming metering; 96 sq.mm Digital type Multifunction meter - 1no (VIF&KW, P.F, Demand controller. Earth fault relay - 1no, RYB indication lamps-1no.D.G.Incoming800A FP 50 KA micro proccesor basedEDO type ACB with shunt Release & UV Release - 1no. DG Incoming Metering, 96 sq.mm Digital type Multi function meter -1no (VIF&KW, P.F, Demand controller. Earth fault relay - 1no, RYB indication lamps-1no. Bus complete ;1600 A FP ACB Without protection 630A FP SDF Double Break switch with DIN Type fuse units - 2Nos.400A TP SDF Double Break switch with HRC Fuse units - 4Nos. 250A TP SDF Double Break switch with HRC Fuse units - 4Nos. 125A TP SDF Double Break switch with HRC Fuse units - 2nos.All Bus bar supports by using MS supported SMC insulating materials.Bus bar jambers : 1\"x1½\"X2\" Copper flat for 3 phases buses.1\"x1½\"X1\" Copper flat for neutral buses.Joints: All Bus bars joints tinned and galvanized bolt nuts with plate & spring washers.INTERLOCKING ARRANGEMENT:Both the EB & DG incomers, Bus couplers mechanically interlocked with three locktwo key systems.The interconnection with the bus bars to the 1600A ACB and 800A ACB should be done by using 1\"x1 1/2\" run of Copper flat. The interconnection with the bus bars to the 630A FP SDF DB switches should be with 1\"x3/4\" run of Copper flat and that for 400A SDF DB Switches with1\"x½\" Copper flat and that for 250A SDF DB Switches with 30mmx6mm Copper flat and that 125A SDF DB Switches with 30mmx3mm Copper flat. And Double earth connection to all the switches should be done using No.8 SWG Copper conductor.The buses should be mounted on the SMC bus insulator at proper & sufficient spacing between the buses as per IE rules.The bus bar chamber should be segregated from the adjacent chamber by providing hylem sheet of 6mm thick as partition.1\"x½\"copper flat should be provided all around the panel for earth connection. Phase & Neutral copper buses should be provided with heat shrinkable sleeves using RYB & Black colours. Indicator lamps should be provided with toggle switches & Bakelite fuse unit.The capacity of fuse switches, size and route location of the UG cable shall be superscribed on all the incoming and outgoing switches.The Panel should be mounted on angle iron frame work of size 3\"x1½\"x¼\" MS channel provided all around the sides of the panel. The whole arrangements should be erected on a suitable masonary pedastal. (All Switches and ACBs should be with ISI mark and of Higher End make only) (DATA-19) |
| 437 | Supply, erection and commissioning of duct and vermin proof type 1600 A capacity Copper Bus duct made out of 16 SWG CR sheet with power coated painting. The bus duct provided with 1600 Amps.Rating CU. Flat for 3 phase and 800 A rating Copper flat for neutral with RYB & N colour sleeving. Bus bar size : 2Runs 100x6mm CU. flat for phase 1Run 100 x 6mm CU.flat for neutral (MR) |
| 438 | 1600A TPNflexible joint Fabrication, supply, erection and commissioning of 1600A flexible joint to the bus bars required to suitable bus bars (MR) |
| 439 | Supply and laying of 11KV Earthed3C X 240 sq.mm X LPEarmouredHTcable in a existing trench (SR) |
| 440 | Supply and providing cable suitable 11KV 3 core 240 sqmm XLPE HT UG cable with necessary indoor type heat shrinkable Termination kit and accessories with termination complete (M-seal/Rechym/Densonmake) (SR) |
| 441 | Supply and providing cable suitable 11KV 3 core 240 sqmm XLPE HT UG cable with necessary outdoor type heatshrinkable Termination kit and accessories with termination complete (M-seal/Rechym/Denson make)(SR) |
| 442 | Supply and fixing of Neutral CTprotection class 300/5A with suitable outdoor type MS enclosure, busbar arrangements with necessary angle iron arrangements, control cable connection from ACB to Neutral CT box etc., |
| 443 | Supply and demonstration of safety accessories AC Chargeable Emergency Lamp 2 x 11W PL Lamp with all connected accessories.(SOR XIII- Part\"M\"8- M-1975) |
| 444 | Supply and demonstration of safety accessories 2m x 1m Rubber Mat suitable for 11 KV installation confirming to IS.(SOR XIII- Part\"M\"8- M-1976) |
| 445 | Supply and demonstration ofFirst Aid Box complete with all First Aid Medicines.(SOR XIII- Part\"M\"8- M-1977) |
| 446 | Supply and demonstration ofShock Treatment Chart fixed in glass frame in Tamil and English (SOR XIII- Part\"M\"8- M-1978) |
| 447 | Supply and demonstration of safety accessories4 Nos. Fire Buckets made out of 40 x 40 x 6mm MS Angle.(SOR XIII- Part\"M\"8- M-1979) |
| 448 | Supply and demonstration of Hand Gloves 11KV Grade.(SOR XIII- Part\"M\"8- M-1980) |
| 449 | Supply and fixing ofDanger Board as required by the Electrical Authorities(SOR XIII- Part\"M\"8- M-1981) |
| 450 | Supply and demonstration of safety accessoriesFire Extinguisher Co2, 4.5 kg. confirming to TAC Norms (SOR XIII- Part\"M\"8- M-1982) |
| 451 | Supply and demonstration of Earth Discharge Rod. (SOR XIII- Part\"M\"8- M-1983) |
| 452 | Supply and demonstration of safety accessoriesBattery water acidity tester -1 no.(MR). |
| 453 | Preparation of site plan, physical layout, electrical line schematic diagram in 10 sets getting drawing approval from CEIG preparation of completion report, rectification report and arranging CEIG inspection and obtaining safety certificate preparation of 1 set of approved drawing and acopy of safety certificate in a neat frame work to be fixed in generator room and payment of CEIG inspection fees.(As per Quotation) |
| 454 | Supply, Erection, Testing & Commissioning of 400A capacity Dust & Vermin proof cubicle panel made out of 16SWG CRCA sheet steel enclosure with supply & fixing of the following interior mounting fuse switches with HRC fuses with a central bus bar chamber & two numbers of Horizontal cable chamber at top and bottom.400A FP SDF Double Break switch withHRC fuse units and Interlock system - 2Nosas incoming.Outgoings: 250A TP SDF Double Break switch with HRC Fuse units - 5Nos.125A TP SDF Double Break switch with HRC Fuse units - 2Nos.The bus bar chamber consist of 4nos. of 50mmx6mm Copper flat for three phases and neutral and also for interconnection for 400A switch. The interconnection with the bus bars to the 250A SDF DB Switches with 30mmx6mm Copper flat and that 125A SDF DB Switches with 30mm x3mm timed copper flat . And Double earth connection to all the switches should be done using No.8 SWG Copper conductor.The buses should be mounted on the SMC bus insulator at proper & sufficient spacing between the buses as per IE rules.The bus bar chamber should be segregated from the adjacent chamber by providing hylem sheet of 6mm thick as partition2 runs of 1\"x¼\" copper flat should be provided all around the panel for earth connection. Phase & Neutral copper buses should be provided with heat shrinkable sleeves using RYB & Black colours. Indicator lamps should be provided with toggle switches & Bakelite fuse unit.The capacity of fuse switches, size and route location of the UG cable shall be superscribed on all the incoming and outgoing switches.The Panel should be mounted on angle iron frame work of size 1½\"x1½\"x¼\" MS channel provided all around the sides of the panel. The whole arrangements should be erected on a suitable masonary pedastal. (All Switches should be with ISI mark and of Higher End make only) (DATA-20) |
| 455 | Supply, Erection, Testing & Commissioning of 400A capacity Dust & Vermin proof cubicle panel made out of 16SWG CRCA sheet steel enclosure with supply & fixing of the following interior mounting fuse switches with HRC fuses with a central bus bar chamber & two numbers of Horizontal cable chamber at top and bottom.400A FP SDF Double Break switch withHRC fuse units and Interlock system - 2Nosas incoming.Outgoings: 250A TP SDF Double Break switch with HRC Fuse units - 2Nos.125A TP SDF Double Break switch with HRC Fuse units - 2Nos.63A TP SDF Double Break switch with HRC Fuse units-8 Nos The bus bar chamber consist of 4nos. of 50mmx6mm Copper flat for three phases and neutral and also for interconnection for 400A switch. The interconnection with the bus bars to the 250A SDF DB Switches with 30mmx6mm Copper flat and that for125A SDF DB Switches with 30mm x 3mm timed copper flat and that for 63A SDF DB suitable with No 8 SWG copper rod. And Double earth connection to all the switches should be done using No.8 SWG Copper conductor.The buses should be mounted on the SMC bus insulator at proper & sufficient spacing between the buses as per IE rules.The bus bar chamber should be segregated from the adjacent chamber by providing hylem sheet of 6mm thick as partition2 runs of 1\"x¼\" copper flat should be provided all around the panel for earth connection. Phase & Neutral copper buses should be provided with heat shrinkable sleeves using RYB & Black colours. Indicator lamps should be provided with toggle switches & Bakelite fuse unit.The capacity of fuse switches, size and route location of the UG cable shall be superscribed on all the incoming and outgoing switches.The Panel should be mounted on angle iron frame work of size 1½\"x1½\"x¼\" MS channel provided all around the sides of the panel. The whole arrangements should be erected on a suitable masonary pedastal. (All Switches should be with ISI mark and of Higher End make only) (DATA-21) |
| 456 | Supply, Erection, Testing & Commissioning of 250A capacity Dust & Vermin proof cubicle panel made out of 16SWG CRCA sheet steel enclosure with supply & fixing of the following interior mounting fuse switches with HRC fuses with a central bus bar chamber & two numbers of Horizontal cable chamber at top and bottom.250A FP SDF Double Break switch withHRC fuse units- 2Nosas incoming.Outgoings: 125A TPN SDF Double Break switch with HRC Fuse units - 2Nos.63ATPN SDF Double Break switch with HRC Fuse units -8NosThe bus bar chamber consist of 4nos. of 30mmx6mm Copper flat for three phases and neutral and also for interconnection for 250A switch. The interconnection with the bus bars to the 125A SDF DB Switches with 30mmx3mm Copper flat and that for 63A SDF DB swiches with No.8 SWG Copper Conductor. And Double earth connection to all the switches should be done using No.8 SWG Copper conductor.The buses should be mounted on the SMC bus insulator at proper & sufficient spacing between the buses as per IE rules.The bus bar chamber should be segregated from the adjacent chamber by providing hylem sheet of 6mm thick as partition2 runs of 1\"x¼\" copper flat should be provided all around the panel for earth connection. Phase & Neutral copper buses should be provided with heat shrinkable sleeves using RYB & Black colours. Indicator lamps should be provided with toggle switches & Bakelite fuse unit.The capacity of fuse switches, size and route location of the UG cable shall be superscribed on all the incoming and outgoing switches.The Panel should be mounted on angle iron frame work of size 1½\"x1½\"x¼\" MS channel provided all around the sides of the panel. The whole arrangements should be erected on a suitable masonary pedastal. (All Switches should be with ISI mark and of Higher End make only) (DATA-22) (All Floor Lighthing Panel) |
| 457 | Design, Supply, Erection and testing of 200kVAR, 415Volts, 50Hz, 3phase, 12 stage switching sequence power factor correction Floor mounting dust and vermin proof cubicle panel board made of 16SWG CRCA sheet steel with 1 1/2 \" x 1 1/2\" 1/2\" AI Frame work with RCC concreting foundation and bolted to masonry pedastalwith supply and fixing of the following interior mounting capacitor chamber, Solid state relays with TM2 technology, with metering chamber and compartmentalised outgoing feeders with suitable capacity MCCB of 400A rating with rotary handle for incoming, with provision for louvers and cooling fan for proper ventilation to manage heat load. Outgoing capacitor bank consits of 12 stages with MPP Capacitors ranging from 2kVAR to 50kVAR as detailed below:1.stage -2KVAR2.stage-3KVAR3.stage-5KVAR4.stage-10 KVAR5.stage-10KVAR6.stage-15KVAR7.stage-15KVAR8.stage-20KVAR9.stage-20KVAR10.stage-25KVAR11.stage-25KVAR12.stage-50KVARBus bar: 2run of 50mm x 6mm tinned copper flatMetering: 1) 0-500A Ammeter with CT coil 2) 0-500V Voltmeter3) R, Y, B indicators4) Advanced micro controller based intelligent power factor controller with self diagnostics sensing and digital network analysis with software for momentary and saving parameter using a suitable multi-function meter and display to show the following parametes.a.Vr-R Phase Voltageb.Vy-Y Phase Voltagec.Vb-B Phase Voltaged. Ir-R Phase Currente. Iy-Y Phase Currentf. Ib-B Phase Currentg. kW - Present Kilo wattsh. RkVA - Present Reactive kVA Demandi. kVA - Present kVAj. pf - Present Power Factork. Number of capacitor bank ON/OFFl. Provision to indicate the imbalanced loadm. Provision to indicate the change in phase sequencen. The APFC Panel should also have built in protection for current imbalance.o. High voltage / low voltage cut off, single phase preventer, provision for inductor coil to cater in-rush currents, line surges, current limiters, current sensor, etc, with connection complete and as per the relavant IE rules. |
| 458 | Supply and laying of2Run 3 ½ x400 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75m putting 0.15mt. Layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good. (Transformer - MV Panel - Rising main) (DATA-23) |
| 459 | Supply and laying of3Run 3 ½ x400 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75m putting 0.15mt. Layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good. (Generator incoming)-(DATA 24) |
| 460 | Supply and laying of3 ½ x 400 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75m putting 0.15mt. Layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good. (In Fire Pump) (SD-214) |
| 461 | Supply and clamping of 3 ½ x 400 sq.mm PVC LTUG armoured LTUG cable on post or on wall with MS Clamps. (SD - 232) (ForPower factor panel) |
| 462 | Supply and fixing of brass cable gland for 3 ½ x 400 sq.mm PVC armoured LTUG cable, with earth connection.(SD-196) |
| 463 | Supply and providing cable end termination of 3 ½ x 400 sq mm PVC LTUG Aluminum armoured cable with necessary aluminium cable sockets by crimping etc. with electrical connection complete (DATA-25) |
| 464 | Supply and clamping of 3 ½ x 150 sq.mm PVC LTUG armoured LTUG cable on post or on wall with MS Clamps. (SD - 228) |
| 465 | Supply and fixing of brass cable gland for 3 ½ x 150 sq.mm PVC armoured LTUG cable, with earth connection.(SD-192) |
| 466 | Supply and providing cable end termination of 3 ½ x 150 sq mm PVC LTUG Aluminum armoured cable with necessary aluminium cable sockets by crimping etc. with electrical connection complete (SD-241) |
| 467 | Supply and laying of 3½ x 185 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 metre layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good.(SD-211) (For Kitchen Block) |
| 468 | Supply and clamping of 3½ x 185 sq.mm PVC LTUG armoured LTUG cable armoured Pipe on post or on wall with MS Clamps.(SD-229) |
| 469 | Supply and fixing of brass cable gland for 3½ x 185 sq.mm PVC armoured LTUG cable, with earth connection.(SD-193) |
| 470 | Supply and providing cable end termination of 3½ x 185sqmm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc. with electrical connection complete (SD-242) |
| 471 | Supply and laying of 3½ x 50 sq. mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75metre putting 0.15mt. Layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good. (SD - 206) |
| 472 | Supply and clamping of 3 ½ x 50 sq.mm PVC LTUG armoured LTUG cable on post or on wall with MS Clamps. (SD - 224) |
| 473 | Supply and fixing of brass cable gland for 3½ x 50 sqmm PVC armoured LTUG cable with earth connection. (SD - 188) |
| 474 | Supply and providing cable end termination of3½ x 50 sqmm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc. with electrical connection complete. (SD - 237) |
| 475 | Design, Engineering, Supply, Fabrication, Erection, Testing, Commissioning and Handing over of 1No. 26 persons 1768kgs. Capacity Passenger cum Bed Lift (Gearless) With Machine Roomas per the following specifications.1. Location : District Head Quarters Hospital at Hosur 2. No. of Lift : One No3. Type of Lift : Passenger cum Bed Lift with machine room - Gearless model4. Capacity of Lift : 26 Persons / 1768kgs5. Speed : 1.0 mtr / sec6. Type of Drive : V3F Drive with enhanced ridecomfort and near ZeroLevel Functions.7. No. ofFloors : Ground floor + 6 Floors8. Total Travel : 22 Mtr / Pit 1800mm / Head room 4800mm9. Leveling accuracy : High level accuracy with smooth and jerk free stopping.10 Construction of Lift well : RCC with brick masonary/ Brick well. 11.Car : 1.5mm hairine finish High QualityS.S. Car and Hand rail, PVC flooring and Perspex False Ceiling.12 Position of Machinery : Directly above the Lift well – Gearless with machine room.13 No. of Landings : 7 Nos in the front side. 14 No. of Car Entrance : One in the front side.15 Car Entrance : Power operated V3F Drive, side opening Sliding Stainless Steel (1.5mm) Hairline finish door.16 Landing Entrance door : side opening SlidingStainless Steel (1.5mm) hairline finish door with provision for Emergency Exit key at All landings. 17 Lift well : 2400mm (Wide) x 3000mm (Depth) as per IS 14655(Part 1) 2000. Lift shaft to be constructed 18 Lift Pit : 1800mmDepth.19 Car Size : 1600 x 2400 x 2200 (mm Widex mm Depth x mm Height as per IS14665 (Part I) 200020 Car Clear Opening of Gates / Doors / Lintel : 1200mm Wide x 2000mmHeight and Lintel : 2300mm asper IS 14665 (Part I) 200020 Power Supply : 400/415V 3phase 50Hz AC Power Supply.21 Type of Control System : Micro Processor based Simplex Selective Collective control with / without attendant.22 Car fittings : LED lights & Regular (Square) cabin fan.23 Lift Well : to be constructed24 Indication : UP / DOWN Digital direction and position indicator for all Landings and inside the car.25 Emergency provisions : Battery operated Alarm bell & Light to be Provided with Automatic charging device.26 Fire Man’s switch : In the Ground Floor27 Minor Builder works : included28 Scaffoldings : included29 Sill angles and Fascio Plates : included30 Steel for LiftMachinery : included31 Servicing and maintenance: Free Comprehensive Maintenance for one YearGuarantee period.32 Automatic Rescue Device : Provision to facilitate the landing to the nearest floor at the time of power failure. The ARD consists of suitable Battery system with charger, Inverter, under voltage protection system etc. complete with all accessories. 33 Provision for Intercom : To be provided in the Ground Floor & Machine Room with Phone (Press & Speak).34 Lift License : Preparation ofDrawings, payment of inspection charges to CEIG and insurance policy and Obtaining CEIG approval for the Lift as per Lift act should be done by the Lift contractor.35 Floor Position : Included with LED display and floor annunciator.36 Special Features:a. Infra red door sensor with full height screen b. S.S. hair finish hand rail in car c.. Vandal proof SS button with SS coverd. S.S. hairline finish door frames for landing doorse. V3F door operatorf. Call register signalg. Stainless steel facio plates for car operatingpanel and landing fixturesh. Steel ladder for Lift machine room in lift pit.i. On / Off switch for fan and lightj. Over-load warning indicator with audioAnnouncerk. Voltage stabilizer for control circuit.35 Over Speed Governor, Phase failure and Phasereversal Relay, alarm bell, T guide brackets for car and counterweight, Rubber padding under the winding unit, Motor of adequate capacity,Electromagnetic brake with compression springs, Car safety gears, Buffers, Electro mechanical locks, Emergency key, side supporting angles, Motor over - load protection devices, Final limit switch main, suspension ropes, Counter weights, Lifting joist for mounting the Machineries.36. Guarantee : Guarantee at least for one year for the materials and workmanship of equipments should be offered by the Lift contractor.37. Site testing in accordance with IS 14665 should be carried out at the time of Handing over to the User department.38. Supply, operation and maintenance manual and necessary tools for operation and a set of spare parts required for one year to be provided.(Johnson/Kone/OTIS)(As per SR Rate) |
| 476 | Dump LiftDesign, Engineering, Supply, Fabrication, Erection, Testing, Commissioning and Handing over of1No. 250KG Dumb lift as per following Technical Specification.1. Type of Lift:Dumb Waiter Service.2. Capacity of Lift:250Kg.3. Speed :0.30 Metre / Sec.4. Type of Drive:Single speed Drive5. No. of Floors : Ground + 6 Floors.6. Total Travel : 22 Metres.7. Over Load warning Indicator and fireman’s Switch to be provided.8. Design of Car: M.S. Painted with M.S. chequered plate flooring.9. Position of Machine : Directly above the lift shaft.10. No. of Landing Entrance : Seven ( in front only) 11. No. of Car Entrance: One (in front only)12. Car Entrance Door:No Door.13. Landing Entrance Door : Collapsilble gate M.S. painted with landing door frames.14. Lift well: 1500 mm (Width) x 1200 mm (depth).15. Lift pit depth (to be constructed) : 1600mm.16. Car Size : 1100mm (Width) x 1200mm (depth).17. Car Clear opening : 740mm wide x 1200mm.18. Lift Machine room (to be constructed) : 1500mm (Width) x 2000mm Depth as per IS 14665 Part-I-2000.19. Power Supply : 400 / 440V 3 Phase, 50 Cycles / sec AC supply for power and 230 V 50HZ single phase AC supply for light. at machine room.20. Extremly Extended push buttons with / without Attentant.21. Car fittings : LED Fittings.22. Lift well : RCC construction with brick masonary.23. Indication: Up / Down Digital for all landings.24. Minor Builder Work: To provided by lift contractor. .25. Scaffolding : To be provided by lift contractor.26. M.S. Sill angles and facia plates : Included.27. Steel for lift machinery : Included.28. Servicing and maintenance : Free comprehensive Servicing and maintenance during the guarantee period of one year.29. Lift License : Preparation of drawing, payment of charges to CEIG / Lift inspectorate and insurance polices if any and obtaining CEIG safety certificate as per lift act.30. Special Feature:(a). “UP and Down arrows in landings only.(b). Steel Cubical for Controller.(c). M.S. Door frames for Landing Entrance.31.Supply of Operation and Maintenance manual with necessary tools for operation. The list of Tools should be furnished by the contractor in a separate sheet duly signed.32.Other Standard Features: Phase failure and phase reversal relay, T-guide brackets for car and counter weight, rubber padding under winding unit, Motor of adequate capacity, electro mechanic brake with compression springs with car safety gear, buffer machanical door locks, emergency key, side supporting angles motor over load protection devices. Final limt switch, main suspension ropes, counter weights, lifting joist for mounting the machineries.(As Per Qtn) |
| 477 | Supply,testing, commissioning and handing over of 1No, 500KVA Diesel generator set of0.8PF, 3phase, 415/ 420Volts, 50Hz, 1500 RPM complete in all respects as detailed below.A) ENGINE :Water cooled diesel engine suitable for generator application with a shaft out put of 608BHP suitable at 1500 RPM under NTP conditions . The engine shall comprise the following standard scope of supply:1) Dry type Air cleaner2) Expansion bellow3) Radiator, radiator fan and mounting4) Air to air charge cooler5) Exhaust gas turbo charger 6) Lube oil cooler and lube oil filter7) Fuel filter (pre and micro) 8) In-line mono-block fuel injection pump with governor and fuel feed pump9) Electronic governor 10)24V battery charging alternator 11)24V Volt electric starter motor 12) Engine test certificate13) Residential Mufler14) Fly wheel with starter ring.Engine instrument panel/mounting: Engine control panel consisting of ON/OFF/START/KEY, lube oil pressure gauge, oil temperature gauge, high water temperature gauge and electronic hour meter and RPM indicator. Safety system of Engine: The engines shall trip for the following conditions with Visual alarm device. 1) Low lubricating oil pressure 2) High water temperature3) Vee - belt failure and over speed 4) Low battery indication.The Engine should be capable of providing 10% over load for one hour for every 11 hours continuous running at full load.B)ALTERNATOR :500KVA/450KW capacity of Brushless Alternator AC 3phase, 50HZ, 415/420Volts, 0.8P.F, 4 wire self exited,self regulated design to run at 1500 RPM under NTP conditions conforming to IS 13364 (part-II) 1992 to be coupled directly to the Diesel engine and test certificateC) AMF CONTROL PANEL: The AMF control panel (cubical) should be fabricated with vermin proof and dust proof best quality sheet steel and floor mounted with removable rear panels and hinged front doors with enamel painted and incorporating the following with suitable provision for connecting incoming and outgoing leads have been made on the control panel complete set.1) 1No AC Ammeter 2) 3Nos current transformer with suitable Ratio3) 1No Ammeter selector switch4) 1No AC voltmeter5) 1No Voltmeter selector switch6) 1No Frequency meter7) 1No KWH meter8) 1No power factor meter9) 1No KW meter 10) Battery charging set comprising of the following for charging the battery from mainsa) Transformer/Rectifierb) DC Ammeterc) Charging rate selector switchd) DC voltmetere) Circuit breakerf) Voltage Regulator g) ON/OFF switch11) 1set Air break contactor with auxiliary neutral contactor for main supply12) 1set low voltage HRC fuse for the short circuit protection of the main supply. 13) 1set alternator contactor with auxiliary neutral contactor. 14) 1set three pole bimetal release for over load protection of the alternator.15) 1set low voltage HRC fuse for the short circuit protection of the alternator16) 1set DC control relays incorporating engine start/stop and failure to start/lockout17) 1set selector switch auto/manual 18) 1No push button “Start”19) 1No push button “Stop”20) 1No push button “Reset”21) 1No signal lamp for indicating load on mains22) 1No signal lamp for indicating load on set 23) 1No signal lamp for indicating set fails to start 24) 1No signal lamp for indicating ‘Set running’25) 1No signal lamp for indicating ‘Battery charger ON’26) 1set pilot lamps of 3Nos27) MCCB of 250A capacity with magnetic thermal over load release, instant short circuit trip and under voltage release switch.28) Rectangular copper bus bars (1No for each phase, neutral and earthing terminal) of adequate capacity duly colour coded with heat shrinkable PVC sleeves. 29) 1No mains voltage monitor30) Hooter/Audio alarm for indication set fails to start and for DG O/L31) 1set timers32) Audio and visual indication arrangements for a) Low lubricating oil pressureb) High water temperaturec) Over speed33) 1No Earth fault relay34) Isolator to Isolate the neutralNote:1. The control panel should be complete with necessary fuses, cables, labels, other accessories with neutral isolation arrangements.2. The engine should trip for the following conditions.a) Low lubricating oil pressureb) High water temperature c) Over speed3.Supply and fitment of Auto mains failure panel to EB service with 800Amps switch and 800A contactors SCUF control relays timers etc.D) ACOUSTIC ENCLOSURE :Acoustic enclosure shall be powder coated and fabricated of 16SWG CRCA MS sheet. The silent canopy shall be nut bolt type construction. Critical processes of punching are done on CNC machine to maintain dimensional accuracy of hole within 0.1mm powder coating done after seven-tank surface preparation process of sheet metal. Canopy panel and door shall have inside lining of FIRE-RETARDANT 64kg/m density mineral wool of 100mm thickness as acoustic material. Four hinged doors shall be provided to canopy. The maximum permissble sound pressure level should be as per the norms prescribed by the Central Pollution Control Board / State Pollution Control Board/ Competent Authority concerned or should be with in 75 db(A) at 1 meter from the enclosure surface whichever is advantageous to the department.The emergency stop should be available on the enclosure panel.The enclosure provided shall be duly approved by the Engine Manufacturer of the Engine provided for Diesel Generator Sets mounted inside and should be to the satisfaction of inspection / testing authority concerned.SURFACE TREATMENT – PAINTING :The enclosure shall be suitably treated for degreasing, de-rusting and phosphating. The canopies are passed through seven-tank treatment thoroughly. ADDITIONAL FEATURES OF CANOPIES :Canopy fabricated on CNC machines with dimensional accuracy of 0.1mm so as to increase its durability. Special designed supporting rips/structures are used in canopies so as to give sturdiness and to reduce the vibrations of the DG sets if any. WORLD CLASS COOLING PACKAGE: Canopies shall have cooling package for which it can perform at 45 deg c/ambient temperature. No grounding required on the ground, only a level surface capable of with standing the DG weight. Lifting hooks shall be provided for the acoustic enclosure, which should be unloaded independently of the DG set. The Gen set frame shall also be provided with hooks for unloading.Temperature rise inside the canopy:Canopies shall be designed so as to maintain the temperature difference between ambient and air inlet at cleaner within the enclosure well with in 5-7 deg centigrade. D) Base FrameBase frame should be fabricated in sheet metal. The base frame is rugged in construction and designed for mounting engine and brush less alternator closely coupled, with cross members mounted on AVM.The base frame shall have provision for mounting of acoustic enclosure on it. The supply of Gen set includes loading, unloading and transportation charges. E) Fuel TankRemovable Fuel tank of atleast 990 Ltrs Capacity shall be fabricated out of 14 SWG CRCA MS sheet and is part of base frame.It is duly painted and fitted with inlet and outlet connections and mechanical fuel gauge.Fuel tank can be easily removed for cleaning or any maintenance. First charging of fuel oil to full capacity and first charging of battery while handing over to dept.Full load testing should done for 8 hrs with water rheostrator of suitable loading elementSupply of tools like such as 15\" cutting plier- 1No, Serew driver 9\" and 6\"\" - 2Nos, DE spaners ( 6 Nos) - 1set, Adjustable spanner - 1No,1/2Hammer - 1 No,spanner for removing engine oil plug-1No,Line tester - 1 No for the maintenance and operation of generator F) Battery2NoS 24V 180 AH battery(Kirloskar/Ashok Leyland/ Cummins/Greaves/ Equivalend) (MR) |
| 478 | Supply and installation ofexhaust piping of sufficient length with suitable MS pipe so as to extend outside the generator with necessary thermal insulation. |
| 479 | Erection of Gen set: Providing suitable concrete foundation with cement concrete 1:2:4 with a minimum height of 3 feet from the floor levelwith sand cushion all around the foundation for erection of 500KVA Diesel Generator set over the existing fountation and erection of generator set with proper alignment over the existing fountation. |
| 480 | Supply and demonstration of the following safety accessories.a) 1 meter x 1 meter x1/2inch 11kv rubber mat - 5Nos.b) one set of 4 nos. 9 liters fire buckets with metal stand frame - 1setc) first aid box with medicine - 1no d) 11 kV rubber hand gloves - 2 nos. e) 2 Kg capacity dry powder type fire extinguishers -1No f) Hand operated pump to transfer fuel from standard barrel to fuel tank-1Nog) First aid chart in Tamil and English -1Noh) Battery water acidity tester -1Noi) Earth discharge rod -1Noj) Danger board-1Nok) PL lamp-1No |
| 481 | Supply and fixing of 65mm dia. (2 -1/2\") GI pipe (class B) of 6metre length with 300mm x 300mm x 6mm MS base plate duly welded at the bottom with concreting with construction of masonary pedestal with suitable SMC box with door arrangement to house 6A SP MCB switch, 2/4 way connector on suitable hylem sheet and supply and fixing of 48W LED street light fitting with LED (Higher end) with 1metre 32mm dia. GI pipe (class B) Complete with suitable MS clamps for LED steet light fitting and SMC box with PVC unsheathed copper leads from SMC box to fitting and with painting of suitable colour.(SD-543) |
| 482 | Supply and laying of 4 x 10 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75metre putting 0.15mt. Layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good. (for St.Light) (SD-202) |
| 483 | Supply andclamping of 4 x 10 sq.mm PVC LTUG armoured LTUG cable on post or on wall with MS Clamps. (for St.Light) (SD-220) |
| 484 | Supply andfixing of brass cable gland for 4 x 10 sq mm PVC armoured LTUG cable, with earth connection. (for St.Light) (SD-182) |
| 485 | Supply and laying of 3½ x 35 sq. mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75metre putting 0.15mt. Layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good. (SD - 205)( Nearby Buildings ) |
| 486 | Supply and clamping of 3 ½ x 35 sq.mm PVC LTUG armoured LTUG cable on post or on wall with MS Clamps. (SD - 223) |
| 487 | Supply and fixing of brass cable gland for 3½ x 35. sqmm PVC armoured LTUG cable with earth connection. (SD - 187) |
| 488 | Supply and providing cable end termination of3½ x 35 sqmm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc. with electrical connection complete. (SD - 236) |
| 489 | Manufacturing , supply and erection of 300mm GI tray to be fixed with the existing wall, Structure or in Trench in suitable angle iron support [MR] |
| 490 | RISING MAIN COPPER: Supply erection, testing and commissioning of 630A 3L+N+PE, Plug in TYPE, 415V 3 Phase and Neutral sandwich Copper bus bar rising main indoor type totally dust and vermin proof with Insl F with suitable GI enclosure of 1.6mm thickness with epoxy painting of RAL7032. Rising main shall be provided with double copper earth bus bar of capacity as per specification for the entire length and cost of earth bus bar shall be included. short circuited rating of 50KA for 1sec. The detailed drawing shall be approved by the department before manufacturing. [Make: CPRI approved make](As per Qtn rate) |
| 491 | Supply, Erection, Testing and commissioning of 630A END Feed unit with 630A 4P MCCB 50kA for 630A Rising mains.(As per SR Rate) |
| 492 | Supply and fixing END cover for 630A Rising main (As per Qtn rate) |
| 493 | Supply and fixing of rigid hanger for 630A rising main. (As per Qtn rate) |
| 494 | Supply and fixing of spring hanger for 630A rising main (As per Qtn rate) |
| 495 | Supply and fixing of Wall support hanger for 630A rising main (As per Qtn rate) |
| 496 | Supply and fixing of Flange end for 630A rising main (As per Qtn rate) |
| 497 | Supply, Testing and commissioning of tap of boxes of the following rising main including interconnecting rising main of 400A 4P MCCB suitable for terminating with 3.5C x 400 sq.mm cable (Schneider / Legrend Make) (As per Qtn Rate) |
| 498 | Supply, Testing and commissioning of tap of boxes of the following rising main including interconnecting rising main of 250A 4P MCCB suitable for terminating with 3.5C x 240 sq.mm cable (Schneider / Legrend Make) (As per Qtn Rate) |
| 499 | Supply and fixing of Horizontal Bend / Vertical Bend(As per Qtn Rate) |
| 500 | Supply and fixing of Horizontal Offset / Vertical Offset / Combination Elbow / T Elbow (As per Qtn Rate) |
| 501 | Supply, Erection, Testing, Commissioning and Handing over of 6 bodies Mortuary CabinetContaining 6 Bodies in each Mortuary Cabinet) Government Hospital – Hosur and Charges towards District Head Quarters Hospital at Hosur at Krishnagiri DistrictMortuary Cabinet Type as detailed Below :(A) Supply, fabrication and erection of one number PUF insulated cabinettype mortuary like Blue Star model No.BMC 610 or equivalent to hold6 bodies in 2-tier arrangement withas per the following specification and provisions.1) External cabinet dimensions of 9.7 feet (w) x 7.7feet (D)x 5.7 feet (H) suitable for bodies cabinet with panel thickness not less than 60mm.2) Insulation with 60mm thick PUF panel with 35 to 40 KG/cumt.3) Panel finish 0.5mm thick stainless steel with in the front side outerand other outer inner areas with 0.5mm thick pre-painted galvanized steel.4) Individual doors for each body with chrome plated hinges and locks.5) All panels to be joined together by means of tongue and groove and locked together by means ofcam locks on each side to ensure air tightness, foamed in PVC bubble gasket in all panels.6)Edge of the doors and door openings to be finished with PVC lining7)Electronic temperature, indicator cum controller, vapor proof incan descent light fixture with lamp with plastic coated globe.B) Supply, fabrication and erection of one number split mounted type rooftop mounted refrigeration system to maintain +2 deg C to +6 deg C inside the 6 body Mortuary cabinet with the following specifications of capacitynot less than 10000 BTU/HR Constructed of G.I.Panels with compressor of make Kirloskar Cope land/equivalent with condenser with condenser coil, evaporator with evaporator fan motor with suction, discharge and liquid refrigerant piping and expansion device etc., complete like Blue Star Model No. BMC 610or equivalent, Operating on with power supply at 230V+/10%/singlePhase/50Hz AC supply.c) Supply, fabrication and erection of 6 Nos, of MS powder coated telescopicstructure sliding in the fixed channel within the cabinet each to hold120kgs of weight when it is stretched fully out.D) Supply, fabrication and fixing of 6 numbers of stainless steel trays with Rollers and bush bearing to keep body on the telescopic structure inside the cabinet.E) Providing drainage piping from the evaporator and cabinet to lead drain water just outside the cabinet room.9) Including Packing and Forwarding Charges. |
| 502 | Supply and fixing of 5000VA UPS with 8 Nos 12 V 150 AH tubular battery [Exide IT 500] with1 hour back up and 48months warrantyfor mentioned capacity on full load operation and the following features.(Make :numeric/exide/microtec/equivalent)a)Inverter shall be free from workmanship defects sharp edges nicks ,scratches ,burs etc, all fasteners shall be fixed properly. The equipments shall be complete with all parts and all parts shall be functional.b)Enclosure shall conform to protection requirement of IRL to IS 13947 (part 1) 1993.c)Switching device shall be MOSFET (or) IGBT.d) Switching frequency shall be above 50HZ.II. Input ; 120 v to 260 v 50 HZ single phase ACIII. Output : The variation in outputvoltage from NO- load to full load expressed as a percentages of no load voltage shall not exceed +1 5% over + 10 % and 20 % variation of the rated DC input voltage. The frequency of the output voltage shall be 50 HZ + 1.3%.IV). Inverter efficiency minimum 85% as per CI.T.93 of ISS.v) Over load: inverter shall with stand 10% overload for at least 10 minutes.V).Protections.VI). a)when the Input voltage goes outside the range 120 to 260 volts, the system shall switch over to inverter mode.b). over voltage short circuit and over load protectionat inverter output terminals.C).Battery reverses polarity.d). Protection against over discharge,The load shall be cut off as soon as the voltage of the battery terminal falls blow.i) 10.5 v for 12 v and ii) 21v for 24v battery system. e). The inverter shall incorporate an arrangements for automatic change over of load from main supply to the inverter AC output incase of failure of mains supply with correct pending indication as per cL; 5.6 of IS 13314/ 1992 f). inverter should have surge protection also VII indicators.a)Following indicators shall be provided.i)Mains presenceii)Mains mode.iii) Battery charging.iv) INVERTER MODE v) Battery low.8 battery bank; 12 Volts lead battery to IS 7372(1995 ) with amdts.No1,2&3 shall be reputed makes .9) Battery stand with wheel angle iron frame arrangement. (SR) |
| 503 | Supply and fixing of 40A DP MCB in Metal box DP enclosure in flush with wall and making good of the concealed portion with earth connection. (Higher End make) (DATA-26) (In UPS Point) |
| 504 | Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection(SD-458) |
| 505 | Supply, erection, testing, commissioning and handing over of 11KV 25KA HT Three panel vacuum Circuit Breakers Switch Board VCB Comprising one number 800A 25 KA VCB as incoming and 2 Nos 630A 25 KA VCB as outgoing panels for indoor installation each panel comprising1. Draw out type 11 KV 25 KA Horizontal Draw out / Horizontal isolation Vacuum Circuit Breaker with Motor (230V AC.) operated spring charged mechanism. Anti Pumping Device 110V DC shunt trip and closing coils (DC source of supply to be derived from a Power Pack suitable for 3 tripping and two closing operation counter, 4 NO + 4 NC spare Aux, contact for customer use, automatic safety shutter, mechanical close / trip knob, mechanical on/off indication, operating hand, 110V AC – 110V DC Power Pack etc(Incoming 1 No. 800A and Outgoing 2 Nos of 630A).2. 11KV / Root 3 / 110V /Root3 – Three phase, 3 Limb 200VA Class 1 Resin Cast Draw Out type Potential transformers complete with HT and LT HRC Fuses(Incoming and outgoing.)3. Current Transformers of 100 – 50/5-5 Amps. Dual Core (Core 1 -15 VA class 1 for metering and core 2-15 VA 5P 10 for protection) for incoming 1 Nos, current transformers of 30/5-5 Amps dual core (Core 1-15VA Class 1 for metering and core 2 – 15VA 5P 10 for protection) for outgoing 2 Nos. 4. Meters : Digital Ammeter with Selector Switch (Incoming and Outgoing .)Digital Voltmeter with Selector Switch (Incoming and outgoing.)Digital Trivector made of L&T / Secure make (Incoming and outgoings)Digital power factor meter – 1 NoDigital Frequency Meter (Incoming 1 No.)5. 5. Protection : Numerical type OC + EF protection relay with MODBUS communication protocol6. TP ND IDMT 2 OC + 1 EF Relay similar like Megawin type MCDG 31 Master trip relayMVAJH 13 7. Breaker ON/OFF Auto trip / Healthy trip / Spring charged indication (Incoming and Outgoing .)8. Phase indicating Lamps RY and B (Incoming 3 Nos.)9. Control wiring10. 630A Copper Bus Bar PVC sleeved and required panel copper earthing.11. Control Switch TNC 12. Trip Circuit Healthy Push Button 13. Common for Switch gear, MCB’s for AC DC Control Heater ON / OFF Switch with space heater and thermostat single phase switch socket, cubicle illumination lamp, Disconnecting type terminal Block etc14. MS sheet enclosure for Indoor Installation Powder Coated with paint shade Siemens Grey. Provision through Bottom entry to receive Incoming or outgoing cable excluding cable glands and cable terminal kit. [DATA-4] Make : Systemcontrol/ Megawin/Kirloskar/equivalent] |
| 506 | Supply and run of 25mm x 3mm tinned copper flat with necessary clamps/ supports on wall/ floor/ ground for earth connection.(SD-76) |
| 507 | Supply and run of 50mm x 6mm tinned copper flat with necessary clamps/ supports on wall/ floor/ ground for earth connection.(DATA-27) |
| 508 | Earthing as per the ISI specification with an earth electrode of 2.1 mt class \"B\" GI pipe of dia not less than 40mm, with copper earth plate of size 125mm x 50mm x 6mm, with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry.(SD-233) |
| 509 | GST |