| 1 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 2 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 3 | Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. |
| 4 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: G.S. Sheet |
| 5 | 12 mm cement plaster of mix1:6 (1 cement: 6 coarse sand) |
| 6 | 6 mm cement plaster of mix :1:3 (1 cement : 3 fine sand) |
| 7 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 8 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer |
| 9 | Providing and fixing machine cut, mirror/ eggshell polished , Granite stone work for wall lining (veneer work) including dado, skirting, risers of steps etc., in required design and pattern wherever required, stones of different finished surface texture, on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) laid and jointed with white cement slurry @ 3.3 kg/sqm including pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing, polishing etc. all complete as per Architectural drawings, and as directed by the Engineer-in-Charge. 18 mm thick Granite stone of any colour and any shade as approved by Engineer-in-Charge . |
| 10 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick |
| 11 | Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with :4.0 mm thick glass panes |
| 12 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :\"1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size). |
| 13 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work |
| 14 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building, all complete as per the architectural drawings, with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand), laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 15 | Painting top of roofs with bitumen of approved quality @ 17kg per 10 sqm impregnated with a coat of coarse sand at 60 cudm per 10 sqm, including cleaning the slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil complete :1 With residual type petroleum bitumen of grade VG -10 |
| 16 | 10 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1:1 (1 clay : 1 cow dung) and covered with flat tile bricks, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat:With common burnt clay F.P.S.(non modular) brick tile of class designation 10 |
| 17 | 10 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1:1 (1 clay : 1 cow dung) and covered with flat tile bricks, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat:With common burnt clay F.P.S.(non modular) brick tile of class designation 10 |
| 18 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter |
| 19 | Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level whiteP.V.C. flushing cistern, including flush pipe, with manually controlleddevice (handle lever) conforming to IS : 7231, with all fittings andfixtures complete, including cutting and making good the walls andfloors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 20 | Providing and fixing white vitreous china flat back or wall corner typelipped front urinal basin of 430x260x350 mm and 340x410x265 mmsizes respectively with automatic flushing cistern with standard flushpipe and C.P. brass spreaders with brass unions and G.I clampscomplete, including painting of fittings and brackets, cutting andmaking good the walls and floors wherever required :One urinal basin with 5 litre white P.V.C. automatic flushing cistern |
| 21 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brasspillar taps, 32 mm C.P. brass waste of standard pattern, includingpainting of fittings and brackets, cutting and making good the wallswherever require:White Vitreous China Wash basin size 550x400 mm witha pair of 15 mm C.P. brass pillar taps |
| 22 | Providing and fixing PTMT bib cock of approved quality and colour. 15mm nominal bore, 86 mm long, weighing not less than 88 gms |
| 23 | Steel work welded in built up sections/framed work including cutting hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required .In gratings frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 24 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces),excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 1.00 mm thick with zinc coating not less than 275 gm/m² |
| 25 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece |
| 26 | Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sqm. Mm F.R. L.S. PVC insulated copper conductor single core cable in surface/ recessed steelconduit, with piano type switch, phenolic laminated sheet suitable size ;M.S. box and earthing the point with 1.5 sq.mm FR L.S.PVC insulatedcopper conductor single core cable as required (Group C).. |
| 27 | Supplying installation, testing and commissioning of bulk head fitting suitable for 60/100 watt GLS lamp complete with Lamp and accessories such as glass, wire guard, lamp etc. including connection as required (Make Surya, Baja, Wipro, Philips, Havells) or as approved by the Engineer-in-charge. |
| 28 | Supplying installation testing and commissioning of energy efficient ceiling, /wall/guarder mounting prewired fluorescent tube light fitting suitable 36/40 watt lamp.The fitting shall be completed with electronic ballast, lamp & holder duty wired up ready for 240 volts, single phase, 50Hz AC supply confirming to IS: 10322 as per quality requirement.Fitting shall be provided with all accessories and mounting arrangement as required, including connection with 1.5 sqm. Mm FR PVC insulated copper conductor single core cable and earthing etc. (Make Surya, Bajaj, Havells, Philips Wipro) or as approved by the Engineer-in-charge. |
| 29 | Supplying installation, testing and commissioning of 1200 mm sweep AC electric ceiling fan capacitor type with double ball bearing complete with down rod, canopies, shackles, blades but with out regulator suitable for operation on 230/240 volts, 50 Hz single phase AC supply including wiring the down road of standard length up to 1 mtr. With 2x1.5 sq. mm PVC insulated copper conductor with fan sheet etc. as required (Make Bajaj, Orient, Usha, Havells polar). |