Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting excetra complete. - (Lift upto 1.5 metre) By Mechanical MeansItem / Page No : 2 / 153Specification No : Bd.A.1Spec. Page No : 259 |
| 2 | Providing and laying Cast in situ/Ready Mix, cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailling out water, formwork, laying/ pumping, compacting and curing, excetra complete, with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed, excetra) (using ARTIFICIAL SAND).Item / Page No : 1 / 175Specification No : Bd.E.1Spec. Page No : 287-288Additional Specifications : 1. With additional specifications for controlled concrete.2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 3 | Providing and laying Cast in situ/Ready Mix, cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailling out water, formwork, laying/ pumping, compacting and curing, excetra complete, with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed, excetra) (using ARTIFICIAL SAND).Item / Page No : 1 / 175Specification No : As per Item No 2aSpec. Page No : ---Additional Specifications : As per Item No 2a |
| 4 | Providing and laying in situ/Ready Mix cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete work in foundations like raft, strip foundations, grillage and footings of reinforced cement concrete columns and steel stanchions, excetra including bailling out water, formwork, cover blocks, compaction, curing and roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel), excetra complete, with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (using ARTIFICIAL SAND).Item / Page No : 11 / 178Specification No : Bd.F.3,B-7Spec. Page No : 298,38-40Additional Specifications : 1. With additional specifications for controlled concrete.2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 5 | Providing and laying in situ/Ready Mix cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete work in foundations like raft, strip foundations, grillage and footings of reinforced cement concrete columns and steel stanchions, excetra including bailling out water, formwork, cover blocks, compaction, curing and roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel), excetra complete, with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (using ARTIFICIAL SAND).Item / Page No : 11 / 178Specification No : As per Item No 3aSpec. Page No : ---Additional Specifications : As per Item No 3a |
| 6 | Providing and laying cast in situ / Ready Mix cement conrete M-20 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete columns as per detailed designs and drawing or as directed, including steel centering, formwork, cover blocks,aying/pumping, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete.with fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 31 / 179Specification No : Bd.F.5,B-7Spec. Page No : 300,38-40Additional Specifications : 1. With additional specifications for controlled concrete.2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 7 | Providing and laying cast in situ / Ready Mix cement conrete M-20 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete columns as per detailed designs and drawing or as directed, including steel centering, formwork, cover blocks,aying/pumping, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete.with fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 31 / 179Specification No : As per Item No 4aSpec. Page No : ---Additional Specifications : As per Item No 4a |
| 8 | Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks,laying/pumping, compaction and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 50 / 181Specification No : Bd.F.6,B-7Spec. Page No : 300-301,38-40Additional Specifications : 1. With additional specifications for controlled concrete.2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 9 | Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks,laying/pumping, compaction and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 50 / 181Specification No : As per Item No 5aSpec. Page No : ---Additional Specifications : As per Item No 5a |
| 10 | Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap/ granite / quartzite/ gneiss metal for reinforced cement concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks,laying / pumping, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 70 / 182Specification No : Bd.F.8,B-7Spec. Page No : 302-303,38-40Additional Specifications : 1. With additional specifications for controlled concrete.2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 11 | Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap/ granite / quartzite/ gneiss metal for reinforced cement concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks,laying / pumping, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 70 / 182Specification No : As per Item No 6aSpec. Page No : ---Additional Specifications : As per Item No 6a |
| 12 | Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap metal for reinforced cement concrete chajja as per detailed design and drawings including centering, formwork, cover blocks, compacting, finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate of natural sand/V.S.I. quality Artificial Sand (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 5 / 184Specification No : BDF-9,B-7Spec. Page No : 303-304,38-40Additional Specifications : 1. With additional specifications for controlled concrete.2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 13 | Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap metal for reinforced cement concrete chajja as per detailed design and drawings including centering, formwork, cover blocks, compacting, finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate of natural sand/V.S.I. quality Artificial Sand (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 5 / 184Specification No : As per Item No 7aSpec. Page No : ---Additional Specifications : As per Item No 7a |
| 14 | Providing and fixing in position thermo mechnically treated FE-500 steel bar reinforcement of various dias for reinforced cement concrete pile caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardis, copings, fins, arches, excetra as per detailed designs, drawings and schedules including cutting, bendding, hooking the bars, binding with wires or tack welding and supporting as requied complete. (For Ground Floor)Item / Page No : 33 / 188Specification No : Bd.F.17Spec. Page No : 306 |
| 15 | Providing and fixing in position thermo mechnically treated FE-500 steel bar reinforcement of various dias for reinforced cement concrete pile caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardis, copings, fins, arches, excetra as per detailed designs, drawings and schedules including cutting, bendding, hooking the bars, binding with wires or tack welding and supporting as requied complete. (For Ground Floor)Item / Page No : 33 / 188Specification No : As per Item No 8aSpec. Page No : ---Additional Specifications : As per Item No 8a |
| 16 | Providing second class burnt brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 in foundations and plinth of inner walls / in plinth of external walls including bailling out water manually, striking joints, on unexposed faces, racking out joints on exposed faces and watering, excetra complete. (using ARTIFICIAL SAND).Item / Page No : 1 / 197Specification No : Bd.G.1Spec. Page No : 313Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 17 | Providing second class burnt brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 in foundations and plinth of inner walls / in plinth of external walls including bailling out water manually, striking joints, on unexposed faces, racking out joints on exposed faces and watering, excetra complete. (using ARTIFICIAL SAND).Item / Page No : 1 / 197Specification No : As per Item No 9aSpec. Page No : ---Additional Specifications : As per Item No 9a |
| 18 | Providing and fixing solid core flush door shutter in single leaf 32 milimetre thick decorative type of exterior grade as per detailed drawings, approved face veneers 3 milimetre thick on both faces or as directed, all necessary beeds, moulding and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides and finishing with french polish, excetra complete. (For Ground Floor)Item / Page No : 9 / 246Specification No : Bd.T.34Spec. Page No : 499 |
| 19 | Filling in plinth and floors with contractors material / brought from outside and approved by Engineer In-Charge, in 15 centimetre to 20 centimetre layers including watering and compaction, excetra complete.Item / Page No : 37 / 157Specification No : Bd.A.11Spec. Page No : 263-264 |
| 20 | Filling in plinth and floors with contractors material / brought from outside and approved by Engineer In-Charge, in 15 centimetre to 20 centimetre layers including watering and compaction, excetra complete.Item / Page No : 37 / 157Specification No : As per Item No 11aSpec. Page No : ---Additional Specifications : As per Item No 11a |
| 21 | Filling in plinth and floors with approved excavated materials in 15 centimetre to 20 centimetre layers including watering and compacting, excetra complete.Item / Page No : 36 / 157Specification No : Bd.A.10Spec. Page No : 262-263 |
| 22 | Providing second class Burnt Brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 superstructure including striking joints, racking out joints, watering and scaffolding, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 5 / 197Specification No : Bd.G.5Spec. Page No : 315Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 23 | Providing second class Burnt Brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 superstructure including striking joints, racking out joints, watering and scaffolding, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 5 / 197Specification No : As per Item No 13aSpec. Page No : ---Additional Specifications : As per Item No 13a |
| 24 | Providing internal cement plaster 12 milimetre thick in a single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 3 / 209Specification No : Bd.L.2Spec. Page No : 368Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 25 | Providing internal cement plaster 12 milimetre thick in a single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 3 / 209Specification No : As per Item No 14aSpec. Page No : ---Additional Specifications : As per Item No 14a |
| 26 | Providing neeru finish to plastered surfaces in all positions including scaffolding and curing, excetra complete. (For Ground Floor)Item / Page No : 15 / 210Specification No : Bd.L.10Spec. Page No : 370 |
| 27 | Providing sand faced plaster externally in cement mortar using approved screened sand in all positions including base coat of 15 milimetre thick in cement mortar 1:4 using waterproofing compound at one killogramme per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment of 6 to 8 milimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days, scaffolding, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 11 / 209Specification No : Bd.L.7Spec. Page No : 369Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 28 | Providing sand faced plaster externally in cement mortar using approved screened sand in all positions including base coat of 15 milimetre thick in cement mortar 1:4 using waterproofing compound at one killogramme per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment of 6 to 8 milimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days, scaffolding, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 11 / 209Specification No : As per Item No 16aSpec. Page No : ---Additional Specifications : As per Item No 16a |
| 29 | Providing and applying interior wall finish luster of approved make on internal wall surface as detailed below scrapping the surface with emery paper and wipe clean wall primer with brush with mineral turpentine with brush 8 to 10 percent and oil 15 to 20 percent with roller and allowing to dry for a period 6 to 8 hours. wall putty with appropriate proportion of water allowing to dry for period 4 to 6 hours.Scrapping withemery paper 180 and wipe clean. Applying wall primer with brush with mineral turpentine 8 to 10 percent and oil 15 to 20 percent with roller. Scrapping emery paper 320 and wipe clean,interior wall finish luster first coat with brush/ rubber/ spray with mineral turpentine 7 to 9 percent and Oil with roller 19 to 21 percent. After 8 hours of activity, applying second coat or wall finish Lustre with mineral turpentine 7 to 9 percent with brush and Oil with roller 19 to 21 percent after allowing dry for the period of 6 to 8 hours activity.(With prior approval of S.E.) (For Ground Floor)Item / Page No : 20 / 228Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 30 | Providing and applying white wash in one coat on old / new plastered or masonry surfaces and asbestos cement sheets including scaffolding and preparing the surface by brushing and brooming down, excetra complete. (For Ground Floor)Item / Page No : 2 / 227Specification No : Bd.P.1Spec. Page No : 411 |
| 31 | Providing and applying two coats of exterior acraylic emulsion paint confirming to corresponding Indian Standard of approved manufacturer and of approved colour to the plastered surfaces including cleaning, preparing the plaster surfaces, applying primer coat, scaffolding, if necessary and watering the surface for two days, excetra complete. (For Ground Floor)Item / Page No : 25 / 225Additional Specifications : The work shall be carried out as per instructions of Engineer in charge. |
| 32 | Providing and fixing in position (as per Indian Standard : 1868/1982) aluminium sliding window of two tracks with rectangular pipe having overall dimentsions 63.50 milimetre X 38.10 milimetre X 1.02 milimetre at weight 0.547 kilogram per running metre and window frame bottom track section 61.85 milimetre X 31.75 milimetre X 1.20 milimetre at weight 0.695 kilogram per running metre. Top and side track section 61.85 milimetre X 31.75 milimetre X 1.30 milimetre at weight 0.659 kilogram per running metre. The shutter should be of bearing bottom 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre. Interlocking secion 40 milimetre X 18 milimetre X 1.10 milimetre at weight 0.469 kilogram per running metre and handle section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre and top section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre as per detailed drawing and as directed by Engineer in-charge with all necessary aluminium sections, fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 milimetre thick plain glass with all required screws and nuts, excetra complete. - With colour anodising with box. (For Ground Floor)Item / Page No : 37 / 251Additional Specifications : The work shall be carried out as per instructions of Engineer in charge. |
| 33 | Providing and laying telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone of 18 milimetre to 20 milimetre thick for door frame / dado / window boxing, excetra on cement mortar 1:6 including filling joints with polymer base filler, nosing the sharp edges wherever necessary, curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 68 / 220Additional Specifications : 1. The work shall be carried out as per the sample approved by the Engineer in-charge and kept in the office of the Executive Engineer.2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 34 | Providing and laying telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone of 18 milimetre to 20 milimetre thick for door frame / dado / window boxing, excetra on cement mortar 1:6 including filling joints with polymer base filler, nosing the sharp edges wherever necessary, curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 68 / 220Specification No : As per Item No 21aSpec. Page No : ---Additional Specifications : As per Item No 21a |
| 35 | Providing and fixing mild steel grill work for windows, ventilators, excetra 15 kilogram per square metre as per drawing including fixtures, necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting, excetra complete. (For Ground Floor)Item / Page No : 2 / 264Specification No : Bd.U.1Spec. Page No : 537 |
| 36 | Providing and applying water proofing treatment using acrylic polymer modified cement based water proofing coating with fiber glass mesh mixing at the rate of powder to liquid (2:1) by weight covering 9 to 10 square metre per kilogram with two coats Using approved chemicals for masonry and concrete surface by brush, covering seven years gaurantee on stamp paper, excetra complete. (For First Floor)Item / Page No : 9 / 206Additional Specifications : The work shall be carried out as per instructions of Engineer in charge. |
| 37 | Providing and laying vitrified matt finish tiles of having size 590 milimetre to 605 milimetre X to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 42 / 217Specification No : Bd.M.12Spec. Page No : 385Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 38 | Providing and laying vitrified matt finish tiles of having size 590 milimetre to 605 milimetre X to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 42 / 217Specification No : As per Item No 24aSpec. Page No : ---Additional Specifications : As per Item No 24a |
| 39 | Providing and fixing machine cut machine polished 18 milimetre to 20 milimetre thick telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on a bed of 1:4 cement mortar including float, filling joints with neat cement slurry, curing, polishing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 35 / 216Specification No : Bd.M.22 BSpec. Page No : 390Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 40 | Providing and fixing black Kadappa stone as shelves 25 milimetre thick machine polished, extending the polish upto 20 centimetre width on lower side, rounding corners, laying in position, jointing with cement mortar bedding in cement mortar 1:4 proportion, curing, excetra complete. (For Ground Floor)Item / Page No : 23 / 215Specification No : Bd.M.29Spec. Page No : 391 |
| 41 | Providing and laying polished Shahabad stone Flooring 25 milimetre to 30 milimetre thick and of required width wide in plain / diamond pattern on a bed of 1:6 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 4 / 213Specification No : Bd.M.3,Spec. Page No : 380Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 42 | Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 milimetre X 450 milimetre size as per detailed drawing including vertical both side polished kadappah stone 25 milimetre to 30 milimetre thick supports with kadappah top 35 milimetre to 40 milimetre thick and polished granite 16 to 20 milimetre top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 centimetre height and top granite of 75 centimetre X 40 centimetre including cutting, opening for sink of required size in kadappah as well as granite excetra complete.(Platform top size 5.00 metre X 0.60 metre and height is 0.75 metre) (For Ground Floor)Item / Page No : 78 / 273Additional Specifications : The work shall be carried out as per instructions of Engineer in charge. |
| 43 | Provoding and fixing high density polyethylen container one piece moulded water tank made out of high density polyethylen and built corrugated inclusive of delivery upto destination housing, fixing of accessaries such as inlet, outlet, overflow pipe inclusive of all Taxes - Capacity between 1000 litres to 20000 litres. (For Ground Floor)Item / Page No : 54 / 280Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 44 | Providing, laying and fixing polyvinyl chloride pipe of 15 milimetre diameter with fittings, such as bends, tees, reducers, clamps, excetra including necessary excavation, trench filling, excetra complete.Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed excetra complete.Item / Page No : 21 / 276Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 45 | Providing, laying and fixing polyvinyl chloride pipe of 75 milimetre diameter with fittings such as bends, tees, reducers, clamps, excetra inclduding necessary excavation, trench filling, excetra complete.Including removing existing pipe line if necessary and conveying and stacking thesame in PWD chowky or as directed excetra complete.Item / Page No : 27 / 276Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 46 | Providing and fixing solid core flush door shutter commercial in single leaf 32 milimetre thick without ventilator commercial type of exterior grade as per detailed drawings, with wrought iron hold fast, stainless steel fixtures and fastenings and handles on both sides and finishing with oil painting three coats, excetra complete. (For Ground Floor)Item / Page No : 10 / 246Specification No : Bd.T.36Spec. Page No : 500 |
| 47 | Providing and fixing in position anodised (as per Indian Standard : 1868-1982) aluminium fixed staggered (Z type) ventilator with aluminium rectangular pipe 63 milimetre X 38.10 milimetre X 1.22 milimetre at weight 0.650 kilogram per running metre, aluminium angle of size 15 milimetre X 15 milimetre X 1 milimetre, aluminium channel of 9 milimetre sizes stainless steel mosquite net of 304 Grade, 4 milimetre thick float glass as detailed drawing and directed by Engineer in-charge, excetra complete. (For Ground Floor)Item / Page No : 78 / 261Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 48 | Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 milimetre to 605 milimetre X 590 milimetre to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 40 / 217Specification No : Bd.M.12Spec. Page No : 385Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 49 | Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 milimetre to 605 milimetre X 590 milimetre to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 40 / 217Specification No : As per Item No 34aSpec. Page No : ---Additional Specifications : As per Item No 34a |
| 50 | Providing and fixing european type wall hung white water closet of approved make with push valve consealed type with cover plate 32 milimetre size of approved make including soil pipe, vent pipe upto outside face of wall, 100 milimetre diameter galvanised iron plug, bend, inlet pipe all fittings, cutting and making good walls, floors, excetra complete. (For Ground Floor)Item / Page No : 86 / 283Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 51 | Providing and fixing first class white glazed earthenware Orissa type water closet pan 580 milimetre diameter including \"P\" or \"S\" trap, cast iron soil and vent pipe upto the outside face of the wall, 1:5:10 cement concrete bedding 15 milimetre thick, 10 litre poly vinyl chloride flushing cistern with all necessary pipe connection, excetra complete. (For Ground Floor)Item / Page No : 33 / 277Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 52 | Providing and fixing coloured glazed earthenware lipped flat back / corner type urinal with polyvinyl chloride automatic flushing cistern of 5 litres capacity with fitting inlet pipe and stop tap, brackets for fixing the cistern, polyvinyl chloride flush pipe with fittings including lead soil pipe, lead trap and soil pipe connection upto the outside face of the wall. (For Ground Floor)Item / Page No : 61 / 271Specification No : Bd.V.27Spec. Page No : 564 |
| 53 | Providing and fixing white glazed earthenware wash hand basin of 63 centimetre X 45 centimetre size including Bib cock stop tap brass heavy 15 milimetre, brackets, rubber plugs and brass chain, stop tap and necessary pipe connection including polyvinyl chloride waste pipe and trap upto the outside face of the wall. (For Ground Floor)Item / Page No : 65 / 272Specification No : Bd.V.30Spec. Page No : 565 |
| 54 | Providing and fixing 15 milimetre diameter screw down bib / stop tap of brass including necessary socket union nut complete. (For Ground Floor)Item / Page No : 40 / 270Specification No : Bd.V.8Spec. Page No : 554 |
| 55 | Providing and laying in position flooring of telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone of approved shade and size 18 milimetre to 20 milimetre thick on a bed of 1:6 cement mortar including cement float, striking joints, pointing in cement mortar 1:3, curing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 34 / 216Specification No : Bd.M.3 BSpec. Page No : 380Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 56 | Providing and laying in position flooring of telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone of approved shade and size 18 milimetre to 20 milimetre thick on a bed of 1:6 cement mortar including cement float, striking joints, pointing in cement mortar 1:3, curing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 34 / 216Specification No : As per Item No 40aSpec. Page No : ---Additional Specifications : As per Item No 40a |
| 57 | Providing and fixing hume pipe septic tank 900 milimetre diameter with vent pipe and cap including excavation and laying.Item / Page No : 18 / 275Specification No : Bd.V.45Spec. Page No : 575 |
| 58 | Providing, laying and fixing polyvinyl chloride pipe of 110 milimetre diameter with fittings such as bends, tees, reducers, clamps, excetra including necessary excavation, trench filling, excetra complete.Including removing existing pipe line if necessary and conveying and stacking thesame in PWD chowky or as directed excetra complete.Item / Page No : 28 / 277Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 59 | Providing and constructing brick masonry inspection chamber 60 centimetre X 45 centimetre X 90 centimetre including 1:4:8 cement concrete foundation, 1:2:4 cement concrete channels, half round glazed stoneware pipes, brick masonary, plastering from inside and farme fixed in cement concrete Cover medium duty 140 kilogram with frame excetra complete. (using ARTIFICIAL SAND).Item / Page No : 12 / 275Specification No : As per Item No 43aSpec. Page No : ---Additional Specifications : As per Item No 43a |
| 60 | Providing and fixing White Glazed Earthenware Squatting plate (Ladies Urinal) with polyvinyl chloride flushing cistern of 5 liters capacity with fitting, inlet pipes and stop tap, brackets for fixing the cistern, 32 milimetre diameter P.V.C flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap, soil pipe connection up to the outside face of the wall. (For Ground Floor)Item / Page No : 58 / 271Specification No : Bd.V.23Spec. Page No : 562 |
| 61 | Providing and fixing board displaying information, such as \"Name of work, Tender cost, Name of Contractor, Work completion and liability period etc\", having rectangular shape of 1.20 metre X 0.90 metre size made out 18 gauge (1.25 milimetre) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols excetra with approved colour shade paint complete, on M.S.angle of size 35 milimetre X 35 milimetre X 3 milimetre frame with properly cross braced mild steel angles of size 35 milimetre X 35 milimetre X 3 milimetre duly painted including two mild steel angle iron posts of size 65 milimetre X 65 milimetre X 6 milimetre, 3.65 metre long painted with alternate black and white bands of 25 centimetre width including all fixtures excetraand fixing the boards in 1:4:8 concrete block of size 60 centimetre X 60 centimetre X 75 centimetre including, excavation, refilling, transportation, and labour etc complete. Spec. number As directed by Engineer in ChargeItem / Page No : 36 / 60Specification No : MoRTH-801Spec. Page No : ---Additional Specifications : The work shall be carried out as per instructions of Engineer in charge. |
| 62 | Royalty charges for various building construction bonafied materials which are used for government bonafied works and for which Royalty charges are to be paid by the contractor. (This Item is to be paid to the contractor only after he pays the Royalty amount to Revenue department and produces the required voucher.)Item / Page No : 3 / 0Additional Specifications : 1. Government of Maharashtra, Revenue and Forest Department Gazette Number 146 Dated 04/06/2021 and Government of Maharashtra Public Works Department State Schedule of Rates 2021-22 General Note Number A(v), Page 5.2. The amount of royalty charges will be paid only after submission of the receipt in original from Revenue authority for payment of royalty to Government, stating the name of work.3. Above / below percentage quoted by the contractor will not be applicable for this item. |
| 63 | Laboratory testing charges for various materials required for items of work, on the basis of testing frequency and charges fixed by Vigilence and Quality Control Circle, Pune.Item / Page No : 4 / 0Additional Specifications : 1. The amount of laboratory testing charges will be paid to contractor only after submission of the original receipt from the Vigillence and Quality Control Office with the name of work mensioned on it.2. Above / below percentage quoted by the contractor will not be applicable for this item.Standard Consistancy, Fineness, Specific Gravity, Setting Time (Initial and Final), Compressive Strength, Soundness Test for Cement1 Test per 50.00 Metric Ton |
| 64 | Fineness Modulus (Sieve Analysis), Silt and Clay Content Test for Artificial Sand1 Test per Source |
| 65 | Compressive Strength of Cement Concrete Cube1 Test for quantity upto 5 cubic metre, 2 Tests for quantity above 5 cubic metre and upto 15 cubic metre, 3 Tests for quantity above 15 cubic metre and upto 30 cubic metre, 4 Tests for quantity above 30 cubic metre and upto 50 cubic metre. For quantity 50 cubic metre and above - 4 Tests + 1 Test for each additional 50 cubic metre |
| 66 | Sieve Analysis Test for Metal below 40 milimetre1 Test per 200.00 Cubic Metre |
| 67 | Water Absorption, Specific Gravity, Impact Value, Crushing Value Test for Metal below 40 milimetre1 Test per Source |
| 68 | Concrete Mix Design (with all tests on basic materials) for Grade M-201 Test per 500.00 Cubic Metre |
| 69 | Tensile Strength, Percent Elongation, Yield Stress, Weight per Metre, Bend / Rebend Test, Proof Stress (Steel Bar upto 16 milimetre)1 Test per 5.00 Metric Ton |
| 70 | Tensile Strength, Percent Elongation, Yield Stress, Weight per Metre, Bend / Rebend Test, Proof Stress (Steel Bar above 16 milimetre)1 Test per 5.00 Metric Ton |
| 71 | Water Absorption, Compressive Strength, Efflorescence Test for Burnt Bricks1 Test per 50000.00 Number |
| 72 | Compressive Strength of Cement Mortar1 Test per Day |
| 73 | Liquid Limit & Plastic Limit for Plinth Filling1 Test per 1000.00 Cubic Metre |
| 74 | Thickness, Mass per Running Metre of Aluminium Section1 Test per Square Metre |
| 75 | Water Absorption, Modulus of Rupture Test for Ceramic / Vitrified Tiles1 Test per 2000.00 Number |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail