Assam Rifles-AR has published Tender For Augmentation Of External Electric Supply At Hq 23 Sect Ar. Submission Date for this Tender is 16-10-2023. Electrical Products Tenders in Aizawl Mizoram. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | M&L for LT feeder piller box (415 volts, 50 hz, 4 wire supply), ground mounted, factory assembled, outdoor type weather and vermin proof, made out of 3.15 mm thick MS sheet CRCA sheet with aluminium bus bar 620 amps capacity set with front hinged opening, rubber lining, locking arrangements painted internally and externally with two coats of synethetic enamel paint over a coat of red oxide primer complete having opening for 400 amps MCCB-01 No as incoming and MCCB 100 amps -06 Nos as outgoing including Voltmeter with selector switch 0 to 500 amps- 01 No, LED indicator lamp (Red, Blue,Yellow) colour complete as required and directed by Engr-in-charge. (Note :MCCB/RCCB/Isolator are paid seperately.) |
2 | (a) S&F 3 pole MCCB, 400A, 35KA |
3 | (b) S&F 3 pole MCCB, 100A, 16KA |
4 | M&L for LT feeder piller box (415 volts, 50 hz, 4 wire supply), ground mounted, factory assembled, outdoor type weather and vermin proof, made out of 3.15 mm thick MS sheet CRCA sheet with aluminium bus bar 200 amps capacity set with front hinged opening, rubber lining, locking arrangements painted internally and externally with two coats of synethetic enamel paint over a coat of red oxide primer complete having opening for 100 amps MCCB-01 No as incoming and MCCB 63 amps -06 Nos as outgoing including Voltmeter with selector switch 0 to 500 amps- 01 No, LED indicator lamp (Red, Blue,Yellow) colour complete as required and directed by Engr-in-charge. (Note :MCCB/RCCB/Isolator are paid seperately.) |
5 | (a) S&F 3 pole MCCB, 100A, 35KA |
6 | (b) S&F 63 amp TPN |
7 | Providing and fixing 400 Amps capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required |
8 | Fixing only LT poles at various locations (diggging out and refix at differnent location) incl earth work as required or as directed by Engr-in-charge. |
9 | Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required |
10 | Supplying and fixing of 4 way (4+12), double door ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : But without MCB/RCCB/Isolator.) |
11 | Supplying and fixing 63 amps, four pole, 415 V, isolatorin the existing MCB DB complete with connections, testing andcommissioning etc. as required. |
12 | Supplying and fixing of 12 ways single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/recess,complete with tinned copper busbar, interconnections, powder painted incl earthing etc. as required. (but without MCB/RCCB/Isolator) |
13 | Supplying and fixing of 8 ways single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/recess,complete with tinned copper busbar, interconnections, powder painted incl earthing etc. as required. (but without MCB/RCCB/Isolator) |
14 | Supplying and fixing of 6 ways single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/recess,complete with tinned copper busbar, interconnections, powder painted incl earthing etc. as required. (but without MCB/RCCB/Isolator) |
15 | Supplying and fixing, 5 A to 32 A rating, 240/415 V, 10 kA, "C"curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required. Single pole and neutral as per approved make. |
16 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C"curve, miniature circuit breaker suitable for inductive load ofsingle pole in the existing MCB DB complete with connections,testing and commissioning etc.as required as perapproved make |
17 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure withcover plate having locking arrangement and watering pipe of2.7 metre long etc. with charcoal/ coke and salt as required. |
18 | Supplying, installing, testing and commissioning of 100 amps capacity TPN tap off box made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing rising mains complete 200 Amps bus bar with TPN disconnector FSU and HRC fuses, connections, earthing etc. as required. . |
19 | Supplying, installing, testing and commissioning of 63 amps capacity TPN tap off box made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing rising mains complete 200 Amps bus bar with TPN disconnector FSU and HRC fuses, connections, earthing etc. as required. . |