Public Works Department-PWD has published Maintenance Of Electronic Installation And Fans Including Compound Lights, Routine Servicing Of Water Coolers And Air Conditioners And Repair Maintenance Of Fire Fighting Pumps Sets At Champs Dseu, Okhla-Ii, Campus, New Delhi-110020. Submission Date for this Tender is 03-10-2023. Fire Fighting Consumable Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | SH-I (Annual comprehensive maintenance of Addressable Fire Alarm System) Comprehensive maintenance of Addressable Fire Alarm System of Notifier make installed at DSEU Okhla-II Champs Campus i/c routine inspection as well as and when required/ cleaning/ servicing of the complete AFA System & 24 Hours call back service for fault rectification etc. Complete as reqd. and as per terms and condition and inventory attached. |
2 | Rectification, Testing, commissioning and ReProgramming of Loops in existing Addressable Fire Alarm System complete repairing and serviceable etc as required. |
3 | SH-II (Routine Maintenance of E&M Services & Fire Fighting System)Routine Maintenance of EI & Fans, Light Points, fan points, exhaust fan points, call bell points, Light and power plug, distribution boards,LT Cubical panels, meter board, sub main wiring, circuit wiring and all type of electrical fittings, i/c compound/ Street light etc. at CHAMPS DSEU Okhla-II on all working days except sunday and Holidays as per terms and conditions as specified by providing following minimum staff:-(a)Wireman- 01No. (9.00 AM to 5.00 PM) (b) Khallasi - 01 No. (9.00 AM to 5.00 PM) |
4 | Operation and Routine Maintenance of Fire Fighting and fire alarm System comprising of Fire Fighting Pumps & Drinking Water Pump Set etc.at CHAMPS DSEU Okhla-II on all working days including sunday and Holidays as per terms and conditions as specified by providing following minimum staff:-(a)Operator cum wireman- 02 Nos. (01 in each shift) (6:00 AM to 2.00 PM & 2:00 PM to 10.00 PM) (b) Khallasi - 01 No.(9.00 AM to 5.00 PM) |
5 | SH-III (Annual Comprehensive Maintenance of Air Conditioning Unit & RO Plant)Annual Semi comprehensive Maintenance of 05 Nos. 50LPH capacity RO system connected with water coolerscleaning of all filters, repair/replacement of all electrical and electronic spare parts and one time replacement of consumables like particulate filter 20"" (2x10"") Sediment filter 20"(2x10"), pre carbon filter 20"" and Post carbon filter 20"(Except TFC Membrance), attending complaits within 24working hours with complete overhauling and servicing etc. as reqd. (5 Nos. RO) |
6 | Supply and replacement of RO TFC membrance 75/80GPD i/c testing, commissioning etc. as reqd. old dismanle retained by the contractor. |
7 | Supply and replacement of 20"Particulate/ Sediment Filteri/c testing, commissioning etc. as reqd. old dismantle retained by the contractor. |
8 | Servicing of existing installed WTAC/STAC of 1.5 TR & 2.0 TR capacity AC and water coolers including cleaning of water tank, checking of unit, greasing, oiling etc. i/c chemical cleaning of condensing & cooling coil with high pressure pump and cleaning of tank of water cooler, changing the air filter, checked & tightening all electric connections, testing the machine etc. as reqd. |
9 | Supply & Charging R-22/410/407/ 32/134a gas in the existing WTAC/STAC of 1.5/2.0 TR unit and water coolersi/c pressure testing, flushing the system and Gas Charging complete as reqd. |
10 | Comprehensive maintenance of WTAC/STAC/ unit and water cooleri/c cleaning of water tank, attending day to day complaints from 9 AM to 5 PM and rectifying the defects, replacement of worn out parts such starting / running capacitor, starting relays, overload relays, thermostate as selector switches, sleeves, knobs, Front grills connectors etc. which required to be replace during comprehensive maintenance & monthly cleaning of filters etc. (Replacement of Compressor, condenser fan, blower, fan/blower motor, Coils, Gas charging etc. not covered under comprehensive maintenance) complete as per terms & condition and direction of Engineer-in-charge. (23Nos.X 2 Months= 46 Nos.) |
11 | SH-IV (Supplying of following items to be used during day to day maintenance) |
12 | 1.5 sq.mm ISI marked, FRLS PVC insulated, single core copper conductor cable. |
13 | 4.00 sq.mm ISI marked, FRLS PVC insulated, single core copper conductor cable. |
14 | 6.00 sq.mm ISI marked, FRLS PVC insulated, single core copper conductor cable. |
15 | S.P. 5/6A one way Modular switch ISI marked. |
16 | S.P. 15/16 A one way modular switch ISI marked. |
17 | 3 Pin 5/6 A Modular Socket outlet ISI marked. |
18 | 6 Pin 15/16A Modular Socket outlet ISI Marked. |
19 | Bell Push modular type. |
20 | Stepped type modular fan regulator(2 module) |
21 | 3 Pole MCCB, 100A, 16kA |
22 | 4 pole MCCB, 100A, 30kA |
23 | 4 Pole MCCB, 200A, 36kA |
24 | 6A, 32A, ratings, SP MCB, "C", curve, 10 KA braking capacity. |
25 | 63 A rating Double Pole isolator |
26 | 100A, 4 pole isolator |
27 | 1200 mm sweep ceiling fan |
28 | Exhaust Fan 300 mm sweep 900 rpm |
29 | Fresh Air fan 200mm |
30 | 400mm sweep wall mounted cabin fan. |
31 | Downlighter of 15-18 Watt LED Square/roundpanel, surface/recess type. |
32 | 2"x2" LED Fitting 36 watt, surface/recess type. |
33 | 100-120 Watt LED Flood light. |
34 | Credit for Dismantle: |
35 | Assorted Ceiling Fans / wall fan |
36 | Assorted Fresh air Fan |
37 | Assorted Exhaust fans |
38 | Assorted Switch /sockets/Regulators |
39 | Assorted all type indoor/outdoor fittings |
40 | Assorted MCB/MCCB |
41 | Assorted wire with insulation copper |