Rural Engineering Services-RES has published Tender For Construction Of Library Room, Computer Room, Art Room And Science Lab In Government Model School, Kunlata, Gangolihat.. Submission Date for this Tender is 09-10-2023. Building Work Tenders in gangolihat Uttarakhand. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 30-Sep-2023 | CORRIGENDUM FOR TIMING FOR BID OPENING | Other | 09-10-2023 |
Sl. No. | Item Description |
1 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal o excavated earth,lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.All kinds of soil |
2 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and rammingof bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. |
3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) |
4 | Random rubble masonry with hard stone in foundation and plinth i levellingup with cement concrete 1:6:12(1 cement:6 coarse sandaggregate 20mm nominal size)at plinth level with 1:6 C/S mortar. |
5 | Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in 1:6 C/S Mortar. |
6 | Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing. 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
7 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
8 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
9 | Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete Thermo-Mechanically Treated bars |
10 | Centring and shuttering including strutting, ropping etc. and removal of form for. |
11 | foundation,footing,bases of columns,etc.for mass concrete |
12 | Lintels,beams,plinth beams,girders,bressumers and cantilevers. |
13 | Columns,Pillars,Piers,Abutments,Posts and Struts. |
14 | Suspended floors,roofs,landings,balconiesandaccess platform. |
15 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) |
16 | Structural steel work riveted,bolted or welded in built up se trusses and framed work,including cutting,hoisting,fixing in and applying a priming coat of approved steel primer all complete: |
17 | 12 mm cement plaster of mix 1:6 C/F sand. |
18 | 15 mm cement plaster of mix 1:6 C/F sand. On rough side of single or half brick wall |
19 | Cement plaster skirting(up to 30cm height) with cement mortar 1:3(1cement:3coarse sand) finished with a floating coat of neat cement.18mm thick |
20 | Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
21 | Cement concrete flooring 1:2:4 (1cement:2 coarse sand:4 grad finished with a floating coat of neat cement including cement slurry 40mm thick with 20mm nominal Size stone. |
22 | Providing and fixing glass strips in joints of metre terrazo/ cement concrete floors. 40 mm wide and 4 mm thick. |
23 | Providing and fixing ISI marked flush door shutters conforming to I non-decorative type, core of block board construction with frame o wood and well matched commercial 3 ply veneering with vertical g bands and face veneers on both faces of shutters 35mmtkick. |
24 | S/ F ofoxidised mild steel double acting spring hinges 150mm For Doors |
25 | S/ F ofoxidised mild steel double acting spring hinges 100mm For Windows |
26 | Providing and fixing aluminium handles ISI marked anodised(anod less than grade AC10 as perIS:1868)transparent or dyed to req.125 mm |
27 | 100mm |
28 | Providing and fixing aluminium tower bolts ISI marked anodised (a not less than grade AC 10 as per IS : 1868 ) transparent or dyed t or shade with necessary screws etc. complete. (i) 300x10mm |
29 | 150x10mm |
30 | Providing and fixing aluminium sliding door bolts ISI marked anodi coating not less than grade AC 10 as per IS : 1868) transparent orcolour or shade with nuts and screws etc. complete.(i)250x16mm |
31 | Providing and fixing aluminium hanging floor door stopper ISI mar (anodic coating not less than grade AC 10 as per IS : 1868) transp required colour and shade with necessary screws etc. complete.Twin rubber stopper |
32 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade New work(two or more Coats)over & including priming coat with cement primer. |
33 | Finishing walls with Two coat Deluxe Multi surface paint system for interiors and exteriors including one coat of Special primer |
34 | Painting wood work with Deluxe Multi SurfacePaint of required shade.Two or more coat applied @0.90ltr/10sqm over an under coat ofprimer applied @0.75ltr/10sqm of approved brand or manufacture. Manufacture |
35 | Painting steel work with Deluxe Multi SurfacePaint of required shade.Two or more coat applied @0.90ltr/10sqm wiyhout priming coat of approved brand or manufacture. |
36 | S/F of glass paneswith putty & nails whereever necessary Float glass panes of thickness 4mm |
37 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. |
38 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size,with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles,including applying a priming coat of approved steel primer.Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size,with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles,including applying a priming coat of approved steel primer. |
39 | Random Rubble Stone Masonry laid in 1:6 cement and sand mortar,in breast walls, retaining walls,parapets,scuppers,etc.including supply of all material,labour,T&P and royaltiies etc.(As per PWD Uttarakhand specifications). |
40 | Random Rubble Stone Masonry laid Dry, in breast walls, retaining walls, etc. including supply of all material, labour, T&P and royaltiies etc. complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203 of MORD Specifiction |
41 | Providing concrete for plain/ reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 |
42 | Cement plum Masonry with 40% plum & 60% 1:3:6 cement concrete including supply of all material, labour, T&P etc. required for proper completion of the work. as per drawings and technical specifications Clause 802, 803, 1202 & 1203 of MORD Specifiction |
43 | HP stone filling in back of walls including supply of all material,labour,T&P etc.required for proper completion of the work. |
44 | Board and photography |
45 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent |
46 | Tile work in skirting,risers of steps and dado (up to 2 m height) ov mmthickbedofcement |
47 | Providing and fixing white vitreous china laboratory sink with C.I. brackets,C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required :Size 600x450x200 mm |
48 | Providing and placing on terrace (at all floor litre levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
49 | Providing and fixing ball valve (brass) of approved quality complete High or low pressure with plastic floats 15 mm nominal bore |
50 | Providing and fixing G.I. pipes complete with G.I. fittings includingrefilling etc. (external work)15 mm dia. nominal bore |
51 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
52 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy