Office of the Director Swach Project has published Tender For Construction Of Sahariya Housing Work At Baran District. Submission Date for this Tender is 10-10-2023. Building Work Tenders in baran Rajasthan. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 28-Sep-2023 | DATE CORRIGENDUM | Date | 29-09-2023 |
2 | 29-Sep-2023 | CORRIGENDUM | Date | 03-10-2023 |
3 | 03-Oct-2023 | DATE CORR | Date | 05-10-2023 |
4 | 05-Oct-2023 | DATE CORRI | Date | 10-10-2023 |
Sl. No. | Item Description |
1 | Earth work in excavation bymechanical means(HydraulicExcavator)/manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sum on plan)includingdressingofsidesand ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositingandrefillingofjhiriwith watering&ramminganddisposalof surplus excavated soil as directed with in a lead of 50 meter. |
2 | All kinds of soils |
3 | Fillingavailableexcavatedearth(excluding rock)intrenchesplinthsideoffoundation etc. in layers not exceeding 20 cm in depth consolidationeachdepositedlayerby ramming and watering including lead up to 50 mtr and with all lift. |
4 | Providing and laying in position cement concreteincludingcuring,compactionetc. completeinspecifiedgradeexcludingthe cost of centering andshuttering -All work up to plinth level. 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
5 | RandomRubblestonemasonryforwith hardstoneinfoundationandplinthin CementSandmortarabove30CMthick wall in: Cement Mortar 1:6 ( 1-Cement : 6-Sand). |
6 | Providing and laying damp-proof course with cement concrete grade M-20 (1 : 2 : 4)mortarprepared .Excluding centring and shutring specification. 125 mm thick. |
7 | Providingandlayinginpositionspecified gradeof cementconcreteforRCC structural elements upto floor fivelevel including curing, compaction, finishing with renderingincementsandmortar1:3(1 cement:3coarsesand)andmakinggood the joints and cost of plastizers( if required) excludingthecostofcentering,shuttering andreinforcement forBeams,suspended floors,roofs,gridershavingslopesupto 15º,landings,balconies,shelves,chajjas, lintels,bands,plainwindowssills, staircases and spiral staircases etc. M20 grade Design Mix |
8 | Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending,placinginpositionandbinding (including cost of binding wire) all complete up to floor five level. Thermo-mechanicallyTreatedbars (Conforming of relevent IS code) |
9 | Centering&shutteringwith plywoodor steelsheetsincludingstrutting,propping bracingbothwayswithsteelprops and removalofformworkforuptofloorfive level for : |
10 | Brick work with F.P.S. bricksof class designation 75 in superstructure above plinthlevel uptofloor Vlevel inall shapes and sizes in : Cementmortar1:6(1cement:6coarse sand) |
11 | Supplying and fixing Stone lintels /bed plates of approved quarry include all item with finishing rough dress motor 1:4 .up to 15 cm thick |
12 | Half brick masonry in Superstructure , above plinth level upto floor Vlevel usingbricksofdesignation75 Cement mortar 1 : 4 (1 cement : 4 coarse sand) |
13 | Kotastoneslabflooring25mmthickover 20mm(average)thick baselaidoverand jointed with grey cement slurry mixed with pigmenttomatchtheshadeoftheslab includingrubbingandpolishingcomplete with skarting as per require base of cement mortar 1 : 4 (1 cement : 4 coarse sand) For areaof each slab from 2001 to 5000 Sq.Cm |
14 | Providing and fixing T-iron frames for doors, windows and ventilators of mild steelTee-sections,joints mitredand welded with 15x3 mm lugs 10cm long embeddedincementconcreteblocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand:6gradedstoneaggregate20mm nominalsize)orwithwoodenplugsand screwsorrawlplugsandscrewsorwith fixing clips or with bolts and nuts as require including fixingofnecessarybutthinges and screwsand applying a primingcoat of approved steel primer. |
15 | Providingandfixing M.S angle lead door shutter in angle iron frame 35x35x 5 mm suitable diagonally bracced with 25x3 mm flat iron above and below lock rail of size 50x5 mm beading extra including all fitting as perdirectionofEngineer-in –charge but exculuding redoxide primer paint (add extra for using G.I sheet 24 S.W.G insteed of M.S Sheet) |
16 | Providing and fixing square bars or other flat welded to window, ventilators etc. (8 mm. square bars for windows) |
17 | Plaster on newsurface on walls in cement sand mortar 1:4 including rackingof joints etc.completefinefinish:20mm thick. |
18 | Plaster on newsurface on walls in cement sand mortar 1:4 including rackingof joints etc.completefinefinish25mm thick. |
19 | 6 mm thick cement plaster to ceiling of mix 1:3 (1cement : 3-fine sand) |
20 | Providing and applying whitewash in to give an even shade including all scaffolding new work three or more coates and painting 2 or more cotesas per incharge of engg. |
21 | With ready mix zink chromate yellow primer of approved brand and manufacture on steel galvanised iron /steel wire |
22 | Painting with synthetic enamel paint of approvedbrandandmanufactureto give an even shade :Two or more coats on new work |
23 | P&FrigidPVCpipefittings(IS:4985mark) of approved quality /make including joining thepipewithsolventcementrubberring and lubricant: |
24 | Wiringoflightpoint/fanpoint/exhaustfan point/ callbellpoint with 1.5sq. mm nominal size FR PVC insulatedunsheathedflexiblecopperconductor1.1 kVgrade and1.5sq.mmnominalsizeFRPVC insulatedunsheathedflexiblecopperearth conductor 1.1 kV grade(IS:694) in recessedISI markedMMS(IS:9537P-III)virginmaterialPVC conduit & it"sISI marked (IS:3419-1988) accessories, roundtiles,1.2mmthick HotDippedGalvanized Modular Box with earth terminal, 10A Modular switch,Modularfaceplatewithgridplate, 3pin ceiling rose/ Holder /3 way connector, screws, makingconnections,testingetc.asrequired. For specification of copperConductor,Phenolic Laminatedsheet"s&Electrical/Wiringaccessories referChapterE - 04, E- 05&E- 07Foradditional technicalparameters of product / work refer |
25 | Short point (up to 3 mtr.) |
26 | Medium point (up to 6 mtr.) |
27 | 25 mm. PVC Conduit |
28 | Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexiblecopperconductor1.1kVgradeand1.5sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessedISImarkedMMS(IS:9537P-III)PVC conduit &it"s ISImarked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required. For specification of copperConductor,Phenolic Laminatedsheet"s&Electrical/Wiringaccessories referChapterE - 04, E- 05&E- 07Foradditional technicalparameters of product / work refer Annexure "A" attached with this BSR |
29 | On board |
30 | Medium point (up to 6 mtr.) |
31 | Providing&Fixingof followingmodular accessories as per PWD specification for electrical Works,made outofunbreakableandfireretardantverginpoly carbonate with brass terminals and captive screws & silveralloycontacttipwithIP-20rating, including all as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technicalparameters of product / work refer Annexure "A" attached with this BSR |
32 | Modular MCB 6 A to 32 ADP |
33 | Providing&Fixingof modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP- 20rating, including allasperpreapprovedby Engineerincharge,makingconnections,testingetc. asrequired.Foradditionaltechnicalparametersof product / work refer Annexure "A" attached with this BSR |
34 | 5 step fan regulator 2 Module 360 dgree rotating |
35 | SupplyinganddrawingFRPVCinsulated& unsheathedflexiblecopperconductorasperPWD specificationforelectricalWorkswithISImarked (IS:694) and as per IS 8130 : 2013 of 1.1 kVgrade . Wireshouldbemadefrom99.90%purity copper, class5strandinginacc.toIS:8130/IEC60228for lowerwattloss,oxygenfreeforlesschancesof oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections withCopperLugsofsuitablesize,Ferrules,testing etc.asrequired.OEMMusthaveitsowninhouse NABL lab setup for all testing facilities for wires. For additionaltechnicalparametersofproduct/work refer Annexure "A" attached with this BSR |
36 | 1 x 1.5 sq.mm |
37 | 2 x 2.5 sq. mm. + 1x1.5sqmm |
38 | P &F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm, 12 mmdia rodfanhook with100 mm length extended on eachside .Allasperpreapproved by Engineerincharge. Foradditionaltechnical parametersofproduct/workreferAnnexure"A" |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy