Assam Rifles-AR has published Tender For Special Repair To 30 Nos T-2 Qtrs By Repairing Of Plaster, Roof Treatment, Sewerage Pipe Line And Periodical Services And Re-Wiring Of Existing Resdl Accn At Pallel.. Submission Date for this Tender is 26-10-2023. Building Work Tenders in Tengnoupal Manipur. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 11-Oct-2023 | Corrigendum in date | Date | 26-10-2023 |
Sl. No. | Item Description |
1 | SCHEDULE ‘A’ PART - I (Repair of buildings) (Bldg No. P/40, P/41, P/43, P/44 & P/45) |
2 | Demolishing of nominal cement concrete (1:3:6) or richer mix manually or by mechanical means including disposal of materials within 50m lead as per direction of Engineer - In- Charge. |
3 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete |
4 | Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) 1ST course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) 2ND course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) 3RD course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area.(iv) 4TH course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm). |
5 | Providing and laying cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) in floor. |
6 | Providing and fixing Ist quality ceramic glazed wall tiles (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size, in skirting, risers of steps and dados, over 12 mm thick bed of CM 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, incl pointing in white cement mixed with pigment of matching |
7 | Providing and laying non skid ceramic floor tiles of size 300x300mm ( thickness to be specified by the manufacturer) of approved make, in all colours and shades except white, Ivory, Grey laid on 20mm thickCM 1:4 (1cement :4 coarse sand), incl grouting the joints with white cement and matching pigments. etc. complete. |
8 | Dismantling of old plaster or skirting raking out joints and cleaning the surface for plaster incl disposal of rubbish to the dumping ground within 50 mtr lead. |
9 | Repair to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sqm and under incl cutting the patch in proper shape, racking out joints and plastering the surface of the walls, including disposal of rubbish to the dumping ground within 50m lead etc. complete with CM 1:4( 1 cement : 4 coarse sand). |
10 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including water thinnable priming coat with cement primer. |
11 | Distempering with 1st quality acrylic distemper (ready made) having VOC content less than 50 gm per ltr. of approved manufacturer and of required shade and colour complete. as per manufacturer"s specification on on Old work (one or more coats) incl preparation of old surface by removing old paint by scrapping, sand papering incl necessary repairs to scratches etc complete on Walls. |
12 | Providing and finishing with two or more coats on new work applied @ 1.67 ltr/10 Sqm with Acrylic smooth exterior paintof required shadeincluding priming coat of exterior primer applied & 2.20kg/10sqm. |
13 | Finishing walls with Acrylic Smooth exterior paint of required shade on Old work (one or more coat applied @ 0.90 ltr/10 sqm) on existing cement paint surface, including removing of old water proofing cement paint by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc complete. |
14 | Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
15 | Providing and Painting one or more coats on old work with synthetic enamel paint of approved brand and manufacture to give an even shade. |
16 | Half brick work with common burnt clay F.P.S (non modular) bricks of class designation 7.5 in superstructure in plinth level in Cement mortar 1:4 (1 cement : 4 coarse sand). |
17 | Providing and laying 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 1:4 (1 cement : 4 fine sand). |
18 | Providing and laying in position cement concrete of 1:3:6 with 20 mm graded stone aggregates including centering and shuttering etccomplete in drain. |
19 | Providing and making plinth protection 50 mm thick of cement concrete (1:3:6) with stone aggr 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. |
20 | Providing and fixing fly proof wire gauge to windows, doors and ventilators with MS flat 15x3mm and nuts & bolts completeof 0.63mm dia wire and 1.4 aperture on both sides. |
21 | Renewing glass panes with putty and nails wherever necessary including racking out the old putty of Float glass panes of thickness 4 mm. |
22 | Renewal of old putty of glass panes (length) |
23 | Providing and fixing to existing door frames 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames |
24 | Dismantling doors shutters including chowkhats, holdfasts etc complete of area3 sqm and below. |
25 | Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete : 100 mm |
26 | Providing and fixing aluminium tower bolts of size : 100x10 mm with necessary screws etc. Complete. |
27 | Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets of 20 mm dia (heavy type). |
28 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead for thickness of tiles 10 mm to 25 mm. |
29 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
30 | Demolishing of nominal cement concrete (1:3:6) or richer mix manually or by mechanical means including disposal of materials within 50m lead as per direction of Engineer - In- Charge. |
31 | Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size). |
32 | Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer"s specification |
33 | Providing and laying APP modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with nonwoven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/litre and viscosity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane. |
34 | SCHEDULE ‘A’ PART - II (Repair of Plumbing and Sanitary fittings) (Bldg No. P/40, P/41, P/43, P/44 & P/45) |
35 | Dismantling of flushing cistern of all types (C.I./PVC/Vitreous China), including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead. |
36 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) of capacity 10 litre,White colour, with all fittings and fixtures complete. |
37 | Providing and fixing of 15 mm nominal outer dia Pipes CPVC pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints etc complete. |
38 | Providing and fixing 25 mm dia nominal bore G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. |
39 | Providing and fixing of 15mm nominal bore CP brass bib cock of approved quality. |
40 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) of 25 mm nominal bore. |
41 | Providing and fixing 15mm nominal bore C.P. brass angle valve for basin mixer, flushing cisternand geyser points of approved quality. |
42 | Providing and fixing 600x450mm beveled edge mirror of superior glass ( of approved quality) complete with 6 mm thick hard board backing fixed to wooden cleats with CP brass screws and washers complete.. |
43 | Providing and fixing on wall unplasticised rigid PVC pipes incl jointing with seal ring, single socketed pipes of 110 mm dia. |
44 | Providing and fixing on wall unplasticised rigid PVC pipes incl jointing with seal ring, single socketed pipes of 75 mm dia. |
45 | Construction of brick masonry manhole in cement mortar (1:4) with RCC top slap with (1:2:4) mix foundation concrete (1:4:8) mix inside plastering 12 mm thick with CM (1:3) finished with floating coat of neat cement and making channel in cement concrete (1:2:4) etc complete with common burnt clay FPS (non modular) bricks. |
46 | Providing and fixing of 100mm dia CP brass shower rose with 15 or 20mm inlet of approved quality. |
47 | SCHEDULE‘A’ PART - I (Internal Electrifications) (Resdl accommodation) |
48 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable and 1.5 sq.mm. FR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required (Group B) |
49 | Supply and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
50 | Supplying and fixing Bell Push modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required |
51 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required |
52 | Rewiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. |
53 | Supplying and fixing 5/6 amps modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
54 | Supplying and fixing 15/16 amps modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
55 | Supply and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
56 | Supply and fixing brass batten/ angle holder including connection etc. as required. |
57 | Providing and fixing 63 Amp TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. |
58 | Supplying and fixing 6 way, Double door, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). |
59 | Supply and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required of 16amp. |
60 | Supply and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connections, testing and commissioning etc. as requiredof 5amp. |
61 | Supplying and fixing3 pin 5/6 amps modular socket outlet on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
62 | Supplying and fixing 6 pin 15/16 amps modular socket outleton the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
63 | Supplying and drawing 2x2.5 Sqm mm of FR PVC insulatedcopper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. |
64 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated, copper conductor, single core cable etc. as required. |
65 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required Upto 450 mm sweep. |
66 | Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pippe of 2.7 metre long etc. (but without charcoal/ coke and salt) as required. |
67 | Wiring for for light/power plug with 4x4sqmm FR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit along with 2 Nos 4sqmm FR PVC insulated copper conductor single core cable for loop earthing as required. |
68 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
69 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor, Single core cable and earthing etc. as required. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail