Tender For Special Repair To Single Offrs Accn And Offrs Md Accn 10 Nos Type - 2 Qtrs And Single Men Living Barrack Of 42 Fd Wksp By Repairing Of Plaster, Roof Treatment, Sunken Slab, Sewerage Pipe Line At Pallel, Tengnoupal-Manipur

Assam Rifles-AR has published Tender For Special Repair To Single Offrs Accn And Offrs Md Accn 10 Nos Type - 2 Qtrs And Single Men Living Barrack Of 42 Fd Wksp By Repairing Of Plaster, Roof Treatment, Sunken Slab, Sewerage Pipe Line At Pallel. Submission Date for this Tender is 20-10-2023. Building Work Tenders in Tengnoupal Manipur. Bidders can get complete Tender details and download the document.




Tender Notice

39784989
Corrigendum : Tender For Special Repair To Single Offrs Accn And Offrs Md Accn 10 Nos Type - 2 Qtrs And Single Men Living Barrack Of 42 Fd Wksp By Repairing Of Plaster, Roof Treatment, Sunken Slab, Sewerage Pipe Line At Pallel
Open Tender
Indian
Manipur
Tengnoupal
20-10-2023

Tender Details

Special Repair To Single Offrs Accn And Offrs Md Accn 10 Nos Type - 2 Qtrs And Single Men Living Barrack Of 42 Fd Wksp By Repairing Of Plaster, Roof Treatment, Sunken Slab, Sewerage Pipe Line At Pallel

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 11-Oct-2023 Corrigendum in date Date 20-10-2023

Key Value

Document Fees
INR 1500 /-
EMD
INR 188100.0 /-
Tender Value
INR 94.01 Lakhs /-

BOQ Items

Name of Work : Special repair to Single/Md Offrs accn, 10 No Type - II Qtrs (G+I) (Bldg No. T-II(N)/CPWD/ 2000), Single Men living Barrack (Bldg No. P/80) of 42 Field Work Shopby repairing of Plaster, roof treatment, sewerage pipe line and periodical services of HQ 26 Sector Assam Rifles at Pallel.
Sl. No. Item Description
1SCHEDULE ‘A’ PART - I (Repair of buildings works) (Bldg No. T-II(N)/CPWD/ 2000)
2Demolishing of nominal cement concrete (1:3:6) or richer mix manually or by mechanical means including disposal of materials within 50m lead as per direction of Engineer - In- Charge.
3Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete
4Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) 1ST course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) 2ND course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) 3RD course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area.(iv) 4TH course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm).
5Providing and laying cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) in floor.
6Providing and laying cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate of 20 mm nominal size) in floor sub base.
7Providing and fixing Ist quality ceramic glazed wall tiles (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size, in skirting, risers of steps and dados, over 12 mm thick bed of CM 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, incl pointing in white cement mixed with pigment of matching
8Providing and laying non skid ceramic floor tiles of size 300x300mm ( thickness to be specified by the manufacturer) of approved make, in all colours and shades except white, Ivory, Grey laid on 20mm thickCM 1:4 (1cement :4 coarse sand), incl grouting the joints with white cement and matching pigments. etc. complete.
9Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
10Dismantling of old plaster or skirting raking out joints and cleaning the surface for plaster incl disposal of rubbish to the dumping ground within 50 mtr lead.
11Repair to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sqm and under incl cutting the patch in proper shape, racking out joints and plastering the surface of the walls, including disposal of rubbish to the dumping ground within 50m lead etc. complete with CM 1:4( 1 cement : 4 coarse sand).
12Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including water thinnable priming coat with cement primer.
13Distempering with 1st quality acrylic distemper (ready made) having VOC content less than 50 gm per ltr. of approved manufacturer and of required shade and colour complete. as per manufacturer"s specification on on Old work (one or more coats) incl preparation of old surface by removing old paint by scrapping, sand papering incl necessary repairs to scratches etc complete on Walls.
14Providing and finishing with two or more coats on new work applied @ 1.67 ltr/10 Sqm with Acrylic smooth exterior paintof required shadeincluding priming coat of exterior primer applied & 2.20kg/10sqm.
15Finishing walls with Acrylic Smooth exterior paint of required shade on Old work (one or more coat applied @ 0.90 ltr/10 sqm) on existing cement paint surface, including removing of old water proofing cement paint by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc complete.
16Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
17Providing and Painting one or more coats on old work with synthetic enamel paint of approved brand and manufacture to give an even shade.
18Half brick work with common burnt clay F.P.S (non modular) bricks of class designation 7.5 in superstructure in plinth level in Cement mortar 1:4 (1 cement : 4 coarse sand).
19Providing and laying 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 1:4 (1 cement : 4 fine sand).
20Providing and laying in position cement concrete of 1:3:6 with 20 mm graded stone aggregates including centering and shuttering etccomplete in drain.
21Providing and making plinth protection 50 mm thick of cement concrete (1:3:6) with stone aggr 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.
22Providing and fixing fly proof wire gauge to windows, doors and ventilators with MS flat 15x3mm and nuts & bolts completeof 0.63mm dia wire and 1.4 aperture on both sides.
23Renewing glass panes with putty and nails wherever necessary including racking out the old putty of Float glass panes of thickness 4 mm.
24Dismantling doors shutters including chowkhats, holdfasts etc complete of area3 sqm and below.
25Providing and fixing 35mm thick factory made laminated flush door shutters decorative type, core of block boards construction with frame of 1st class hard wood including stainless steel butt hinges with screws etc complete.
26Providing and fixing paneling or paneling and glazing in paneled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Paneling for paneled or paneled and glazed shutters 25 mm to 40 mm thick with 2nd class teak wood.
27Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia. wire and 1.4mm wide aperture with matching wood beading
28Providing and fixing 25 mm thick flush shutter for Cupboard decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of , including ISI marked nickel plated bright finished M.S. Piano hinges with necessary screws et complete.
29Providing and fixing to existing door frames 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames
30Providing and fixing chromium plated brass handles with necessaryscrews etc. complete : 100 mm, transparent or dyed to required colour or shade, with necessary screws etc. complete
31Providing and fixing chromium plated brass handles with necessary screws etc. completeof size : 75 mm, transparent or dyed to required colour or shade, with necessary screws etc. complete
32Providing and fixing aluminium tower bolts of size : 150x10 mm with necessary screws etc. Complete.
33Providing and fixing aluminium tower bolts of size : 100x10 mm with necessary screws etc. Complete.
34Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets of 20 mm dia (heavy type).
35Demolishing of nominal cement concrete (1:3:6) or richer mix manually or by mechanical means including disposal of materials within 50m lead as per direction of E- In- C.
36Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size).
37Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer"s specification
38Providing and laying APP modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with nonwoven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/litre and viscosity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane.
39SCHEDULE ‘A’ PART - II (Repair of Plumbing and Sanitary fittings) (Bldg No. T-II(N)/CPWD/ 2000)
40Dismantling of flushing cistern of all types (C.I./PVC/Vitreous China), including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead.
41Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required of White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
42Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require of White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
43Providing and fixing of 15 mm nominal outer dia Pipes CPVC pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints etc complete.
44Providing and fixing 20 mm dia nominal bore G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc in Internal work (Exposed on wall).
45Providing and fixing 25 mm dia nominal bore G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.
46Providing and fixing of 15mm nominal bore CP brass bib cock of approved quality.
47Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) of 25 mm nominal bore.
48Providing and fixing 15mm nominal bore C.P. brass angle valve for basin mixer, flushing cisternand geyser points of approved quality.
49Providing and fixing 600x450mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board backing fixed to wooden cleats with CP brass screws and washers complete..
50Providing and fixing on wall unplasticised rigid PVC pipes incl jointing with seal ring, single socketed pipes of 110 mm dia.
51Providing and fixing on wall unplasticised rigid PVC pipes incl jointing with seal ring, single socketed pipes of 75 mm dia.
52Construction of brick masonry manhole in cement mortar (1:4) with RCC top slap with (1:2:4) mix foundation concrete (1:4:8) mix inside plastering 12 mm thick with CM (1:3) finished with floating coat of neat cement and making channel in cement concrete (1:2:4) etc complete with common burnt clay FPS (non modular) bricks.
53Providing and fixing of 100mm dia CP brass shower rose with 15 or 20mm inlet of approved quality.
54SCHEDULE ‘A’ PART - III (Internal Electrifications) (Bldg No. T-II(N)/CPWD/ 2000)
55Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable and 1.5 sq.mm. FR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required (Group B) .
56Supply and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
57Supplying and fixing Bell Push modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required
58Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required
59Rewiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required.
60Supplying and fixing 5/6 amps modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
61Supplying and fixing 15/16 amps modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
62Supply and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
63Supply and fixing brass batten/ angle holder including connection etc. as required.
64Providing and fixing 63 Amp TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc
65Supplying and fixing 6 way, Double door, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
66Supply and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required of 16amp
67Supply and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required of 5amp
68Supplying and fixing3 pin 5/6 amps modular socket outlet on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
69Supplying and fixing 6 pin 15/16 amps modular socket outleton the existing modular plate & switch box including connections but excluding modular plate etc. as required.
70Supplying and drawing 2x2.5 Sqm mm of FR PVC insulatedcopper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required.
71Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated, copper conductor, single core cable etc. as required.
72Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required Upto 450 mm sweep.
73Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 m long etc. (but without charcoal/ coke and salt) as required.
74Wiring for light/power plug with 4x4sqmm FR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit along with 2 No 4sqmm FR PVC insulated copper conductor single core cable for loop earthing as required.
75Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
76Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
77SCHEDULE ‘A’ PART - IV (Repair of buildings) (Single/Md Offrs accn)
78Dismantling of old plaster or skirting raking out joints and cleaning the surface for plaster incl disposal of rubbish to the dumping ground within 50 mtr lead.
79Repair to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sqm and under incl cutting the patch in proper shape, racking out joints and plastering the surface of the walls, including disposal of rubbish to the dumping ground within 50m lead etc. complete with CM 1:4( 1 cement : 4 coarse sand).
80Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 m lead as per direction of E- In - C of nominal concrete 1:3:6 or richer mix (i/c equivalent design mix).
81Providing and laying vitrified floor tiles in sizes 600mm x 600mm(thickness to be specified by the manufacturer) with water absorption less than 0.08%, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
82Providing and laying Vitrified tiles in sizes 600 X 600mm (thickness to be specified by manufacturer), of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete
83Marble stone flooring with 18 mm thick Udaipur green marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with.
84Extra for Marble stone flooring with 18 mm thick Udaipur green marble stone, in treads of steps and risers using single length up to 2 m .
85Finishing walls with Acrylic Smooth exterior paint with silicone additive of required shade on new work (Two or more coat applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm).
86Providing and finishing with two or more coats applied @ 1.43 ltr/10 Sqm over existing cement paint surface Premium Acrylic smooth exterior paint with silicon additives of required shadeincluding removing of old water proofing cement paint by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc complete.
87Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer , over the plastered wall surface to prepare the surface even and smooth complete.
88Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including water thinnable priming coat with cement primer.
89Distempering with 1st quality acrylic distemper (ready made) having VOC content less than 50 gm per ltr. of approved manufacturer and of required shade and colour complete. as per manufacturer"s specification on Old work (one or more coats) incl preparation of old surface by removing old paint by scrapping, sand papering incl necessary repairs to scratches etc complete on Walls.
90Providing and Painting one or more coats on old work with synthetic enamel paint of approved brand and manufacture to give an even shade.
91Providing and laying PCC (1:3:6) in floor sub base with 20mm stone aggregates.
92Half brick work with common burnt clay F.P.S (non modular) bricks of class designation 7.5 in superstructure in plinth level in Cement mortar 1:4 (1 cement : 4 coarse sand).
93Providing and laying 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 1:4 (1 cement : 4 fine sand).
94Providing and laying in position cement concrete of 1:3:6 with 20 mm graded stone aggregates including centering and shuttering etccomplete in drain.
95Providing and making plinth protection 50 mm thick of cement concrete (1:3:6) with stone aggr 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.
96Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size).
97Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer"s specification
98Providing and laying APP modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with nonwoven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 liter/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/liter and viscosity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane.
99Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 m lead of area 3 sqm and below.
100Providing and fixing fly proof wire gauge to windows, doors and ventilators with MS flat 15x3mm and nuts & bolts completeof 0.63mm dia wire and 1.4 aperture on both sides.
101Renewing glass panes, with putty and nails wherever necessary including racking out the old putty with float glass panes of thickness 4 mm.
102Providing and fixing 35mm thick factory made laminated flush door shutters decorative type, core of block boards construction with frame of 1st class hard wood including stainless steel butt hinges with screws etc complete
103Providing and fixing of mosquito proof shutters using galvanized MS wire gauge of average width of aperture 1.4mm in both directions with wire of dia 0.63mm for door of 35mm with 2nd class teak wood.
104Providing and fixing to existing door frames 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames
105Providing and fixing chromium plated brass handles with necessaryscrews etc. complete : 100 mm, transparent or dyed to required colour or shade, with necessary screws etc. complete
106Providing and fixing aluminum tower bolts of size : 100x10 mm with necessary screws etc. Complete.
107Supply and fixing aluminum sliding door bolts, transparent or dyed to required colour or shade, with nuts and screws etc complete of size 250x16mm.
108Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated bracketsof 25 mm dia (heavy type).
109SCHEDULE ‘A’ PART - V (Internal Electrifications) (Single/Md Offrs accn)
110Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable and 1.5 sq.mm. FR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit incl dismantling as required (Group B)
111Supply and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
112Supplying and fixing 5/6 amps modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
113Supplying and fixing 15/16 amps modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
114Supply and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
115Supply and fixing brass batten/ angle holder including connection etc. as required.
116Providing and fixing 63 Amp TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc.
117Supplying and fixing 6 way, Double door, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
118Supply and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required of 16amp
119Supply and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required of 5amp.
120Supplying and fixing3 pin 5/6 amps modular socket outlet on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
121Supplying and fixing 6 pin 15/16 amps modular socket outleton the existing modular plate & switch box including connections but excluding modular plate etc. as required.
122Supplying and drawing 2x2.5Sqm mm of FR PVC insulatedcopper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required.
123Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated, copper conductor, single core cable etc. as required.
124Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required Upto 450 mm sweep.
125Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 m long etc. (but without charcoal/ coke and salt) as required.
126Switch fuse disconnector unit TPN, 62 Amps, 415 volts.
127Wiring for light/power plug with 4x4sqmm FR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit along with 2 Nos 4sqmm FR PVC insulated copper conductor single core cable for loop earthing as required
128Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
129Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required.
130SCHEDULE ‘A’ PART -VI (Repair of Plumbing and Sanitary fittings) (Single/Md Offrs accn)
131Dismantling of flushing cistern of all types (C.I./PVC/Vitreous China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead.
132Providing and fixing 10 ltr capacity (white) P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete.
133Providing and fixing white vitreous china pedestal type water closet (European type) with with ISI marked white solid plastic seat and lid, 10 liter low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required.
134Providing and fixing 20 mm dia nominal bore G.I. Pipes complete with G.I. Fittings and clamps, i/c cutting and making good the walls etc.
135Providing and fixing 15 mm dia nominal bore G.I. Pipes complete with G.I. Fittings and clamps, i/c cutting and making good the walls etc.
136Providing and fixing 25 mm dia nominal bore G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc.
137Providing and fixing of 15mm nominal bore CP brass bib cock of approved quality.
138Providing and fixing of 20 mm dia brass stop cock of approved quality etc. Complete.
139Providing and fixing 15mm nominal bore C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.
140Providing and fixing of PTMT towel rail ring trapezoidal shape 215mm long, 200mm wide with minimum distances of 37mm from wall face with concealed fittings arrangement of approved quality of 600mm long.
141Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
142Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, incl painting of fittings and brackets, cutting and making good the walls wherever requireWhite Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps.
143Providing and fixing 600x450mm beveled edge mirror of superior glass ( of approved quality) complete with 6 mm thick hard board backing fixed to wooden cleats with CP brass screws and washers complete..
144Providing and fixing on wall unplasticised rigid PVC pipes incl jointing with seal ring, single socketed pipes of 110 mm dia.
145Providing and fixing on wall unplasticised rigid PVC pipes incl jointing with seal ring, single socketed pipes of 75 mm dia.
146Construction of brick masonry manhole in cement mortar (1:4) with RCC top slap with (1:2:4) mix foundation concrete (1:4:8) mix inside plastering 12 mm thick with CM (1:3) finished with floating coat of neat cement and making channel in cement concrete (1:2:4) etc complete with common burnt clay FPS (non modular) bricks.
147Providing and fixing of 15mm nominal bore CP angle cock of approved quality.
148Providing and fixing of 100mm dia CP brass shower rose with 15 or 20mm inlet of approved quality.
149Providing and fixing 25mm nominal bore gun metal gate valve with CI wheel of approved quality ( screwed end)
150SCHEDULE ‘A’ PART - VII (Repair of buildings) (SM Bk (Bldg No. P/80)
151Dismantling of old plaster or skirting raking out joints and cleaning the surface for plaster incl disposal of rubbish to the dumping ground within 50 mtr lead.
152Repair to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sqm and under incl cutting the patch in proper shape, racking out joints and plastering the surface of the walls, including disposal of rubbish to the dumping ground within 50m lead etc. complete with CM 1:4( 1 cement : 4 coarse sand)
153Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 m lead as per direction of Engineer - in- charge.
154Half brick work with common burnt clay F.P.S (non modular) bricks of class designation 7.5 in superstructure above plinth level in Cement mortar 1:4 (1 cement : 4 coarse sand).
155Providing and laying 15 mm cement plaster on rough side of single or half brick wall ofcement of mix 1:4 (1 cement : 4 coarse sand)
156Reinforced cement concrete work in suspended floors, shelves, chajjas, lintels etc above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
157Providing and fixing in position of reinforcement (TMT bar), incl cutting to length, bent to shape requirered including crancking, bending etc complete.
158Centering and shuttering incl struting, propping etc and removal of form for slab.
159Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of CM 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with Udaipur green marble.
160Pre finished nosing to treads of steps of marble stone
161Providing and laying Non skid Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete
162Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours,shades except burgundy, bottle green, black of any size as approved by Engineerin- Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
163Providing and laying vitrified floor tiles in 500x500mm sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.
164Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 m lead for thickness of tiles 10 mm to 25 mm.
165Finishing walls with Acrylic Smooth exterior paint with silicone additive of required shade on new work (Two or more coat applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm).
166Providing and finishing with two or more coats applied @ 1.43 ltr/10 Sqm over existing cement paint surface Premium Acrylic smooth exterior paint with silicon additives of required shadeincluding removing of old water proofing cement paint by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc complete.
167Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer , over the plastered wall surface to prepare the surface even and smooth complete.
168Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on new work (two or more coats) over and including water thinnable priming coat with cement primer.
169Distempering with oil bound washable distemper approved brand and manufacturer to given an even shad in old work (one or more coats) incl preparation of old surface by removing old paint by scrapping, sand papering incl necessary repairs to scratches etc complete.
170All as per Item No 7.19 as Above but on ceiling
171Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade,One or more coats on old work.
172Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 m lead nominal concrete 1:3:6 or richer mix in floor.
173Providing and laying PCC (1:3:6) in floor sub base with 20mm stone aggregates.
174Half brick work with common burnt clay F.P.S (non modular) bricks of class designation 7.5 in superstructure in plinth level in Cement mortar 1:4 (1 cement : 4 coarse sand).
175Providing and laying 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 1:4 (1 cement : 4 fine sand)
176Providing and laying in position cement concrete of 1:3:6 with 20 mm graded stone aggregates including centering and shuttering etccomplete in drain.
177Providing and making plinth protection 50 mm thick of cement concrete (1:3:6) with stone aggr 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.
178Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with nonwoven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane.
179Painting with aluminium paint of approved brand and manufacture to give an even shade, one or more coats on old work .
180Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead of area 3 sq. metres and below.
181Providing and fixing fly proof wire gauge to windows, doors and ventilators with MS flat 15x3mm and nuts & bolts completeof 0.63mm dia wire and 1.4 aperture on both sides.
182Renewal of old putty of glass panes (length).
183Renewing glass panes, with putty and nails wherever necessary including racking out the old putty with float glass panes of thickness 4 mm.
184roviding and fixing 35mm thick factory made laminated flush door shutters decorative type, core of block boards construction with frame of 1st class hard wood including stainless steel butt hinges with screws etc complete.
185Dismantling doors shutters including chowkhats, holdfasts etc complete of area3 sqm and below.
186Providing and fixing of mosquito proof shutters using galvanized MS wire gauge of average width of aperature 1.4mm in both directions with wire of dia 0.63mm for door of 35mm with 2nd class teak wood.
187Providing and fixing to existing door frames, 25 mm thick PVC flush door shutters made out of a one piece Multi chamber extruded PVC section of the size of 762 mm x25 mm or less as per requirement with an average wall thickness of 1 mm (± 0.3 mm). PVC foam end cap of size 23x10 mm are provided on both vertical edges to ensure the overall thickness of 25 mm. M.S. tube having dimensions 19 mm x 19 mm and 1.0 mm (± 0.1 mm) is inserted along the hinge side of the door. Core of the door shutter should be filled with High Density Polyurethane foam. The Top & Bottom edges of the shutter are covered with an end-cap of the size 25 mm X 11 mm. Door shutter shall be reinforced with special polymeric reinforcements as per manufacturer’s specification and direction of Engineer-in-charge to take up necessary hardware and fixtures. Stickers indicating the locations of hardware will be pasted at appropriate places.
188Providing and fixing aluminium handles of size : 100 mm, transparent or dyed to required colour or shade, with necessary screws etc. complete
189Providing and fixing aluminium tower bolts of size : 100x10 mm with necessary screws etc. Complete.
190Supply and fixing aluminum sliding door bolts, transparent or dyed to required colour or shade, with nuts and screws etc complete of size 250x16mm.
191Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated bracketsof 25 mm dia (heavy type).
192SCHEDULE ‘A’ PART - V (Repair of Plumbing ) (SM Bk (Bldg No. P/80)
193Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead.
194Providing and fixing 10 ltr capacity (white) P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete.
195Providing and fixing white vitreous china water closet squatting pan (Indian type) : Orissa pattern W.C. pan of size 580x440 mm.
196Providing and fixing 20 mm dia nominal bore G.I. Pipes complete with G.I. Fittings and clamps, i/c cutting and making good the walls etc.
197Providing and fixing 15 mm dia nominal bore G.I. Pipes complete with G.I. Fittings and clamps, i/c cutting and making good the walls etc.
198Providing and fixing 25 mm dia nominal bore G.I. Pipes complete with G.I. Fittings including trenching and refilling etc.
199Providing and fixing of 15mm nominal bore CP bib cock of approved quality.
200Providing and fixing of 20 mm dia brass stop cock of approved quality etc. Complete.
201Providing and fixing 15mm nominal bore C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.
202Providing and fixing of PTMT towel rail ring trapezoidal shape 215mm long, 200mm wide with minium distances of 37mm from wall face with concesled fittings arrangement of approved qaulity of 600mm long.
203Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
204Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, incl painting of fittings and brackets, cutting and making good the walls wherever requireWhite Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps.
205Providing and fixing 600x450mm beveled edge mirror of superior glass ( of approved quality) complete with 6 mm thick hard board backing fixed to wooden cleats with CP brass screws and washers complete.
206Providing and fixing on wall unplasticised rigid PVC pipes incl jointing with seal ring, single socketed pipes of 110 mm dia.
207Providing and fixing on wall unplasticised rigid PVC pipes incl jointing with seal ring, single socketed pipes of 75 mm dia.
208Construction of brick masonry manhole in cement mortar (1:4) with RCC top slap with (1:2:4) mix foundation concrete (1:4:8) mix inside plastering 12 mm thick with CM (1:3) finished with floating coat of neat cement and making channel in cement concrete (1:2:4) etc complete with common burnt clay FPS (non modular) bricks.
209Providing and fixing of 15mm nominal bore CP angle cock of approved quality.
210Providing and fixing of 15mm nominal bore connection pipe of approved quality.
211Providing and fixing of 100mm dia CP brass shower rose with 15 or 20mm inlet of approved quality.
212Providing and fixing 25mm nominal bore gun metal gate valve with CI wheel of approved quality ( screwed end)
213SCHEDULE ‘A’ PART - V (Internal Electrifications) (SM Bk (Bldg No. P/80)
214Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable and 1.5 sq.mm. FR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit incl dismantling as required (Group B)
215Supply and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
216Supplying and fixing 5/6 amps modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
217Supplying and fixing 15/16 amps modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
218Supply and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
219Supply and fixing brass batten/ angle holder including connection etc. as required.
220Providing and fixing 63 Amp TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc.
221Supplying and fixing 6 way, Double door, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
222Supply and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required of 16amp
223Supply and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required of 5amp.
224Supplying and fixing3 pin 5/6 amps modular socket outlet on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
225Supplying and fixing 6 pin 15/16 amps modular socket outleton the existing modular plate & switch box including connections but excluding modular plate etc. as required.
226Supplying and drawing 2x2.5Sqm mm of FR PVC insulatedcopper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required.
227Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated, copper conductor, single core cable etc. as required.
228Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required Upto 450 mm sweep.
229Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 m long etc. (but without charcoal/ coke and salt) as required.
230Switch fuse disconnector unit TPN, 62 Amps, 415 volts.
231Wiring for light/power plug with 4x4sqmm FR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit along with 2 Nos 4sqmm FR PVC insulated copper conductor single core cable for loop earthing as required
232Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
233Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required.