| Sl. No. | Item Description |
| 1 | (B&R PORTION)Dismantling old unserviceable single layer Manglore pattern or similar tiles in roofing and removing rubbish off the premises complete all as specified and directed. |
| 2 | Dismantling battens for tiles, shingle etc. of any size including tilting fillets spaced exc. 15 cm complete all as specified and directed. |
| 3 | S & F for rolled mild steel as in Joist, channel, angle, or tee sections, fixed independently, without connection plate, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) (Fe 410-w (Gde - E-250) quality -A complete all as specified and directed. |
| 4 | S&F pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/clading to wall, fixed with self tapping screwscomplete all as specified and directed. |
| 5 | S&F pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/clading to wall, fixed with self tapping screws as specified complete all as specified and directed. |
| 6 | Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) or insulation boards/slabs/blankets any thickness including cover fillets complete all as specified and directed. |
| 7 | M & L for anodised aluminium snap grid frame work with size of grid 605mm x 605mm for false ceiling all as specified and directed. |
| 8 | M & L for 12 mm thick Perforated particle board/tiles for insulation and acoustic purposes, 60cm x 60cm in size, fixed with nails to timber frame work or with staples on snap grid incl 4mm dia GI mild steel plain wire complete all as specified & directed. |
| 9 | Complete removal of entire existing water proofing treatment in any position including tarfelt, Plaster, lean concrete of any thickness, gravels etc. and removing the debries out side MD land complete all as specified and directed. |
| 10 | M&L for rendering15 mm thick in two layers (10mm+5mm) in CM 1:3 over concrete surfacesmixed with water proofing compound @ 3% by weight of cementin longitudinal &transverse directions finished even and smooth with using extra cement and applying chemical treatment by authorised professional applicators complete all as specified and directed.Note: Water Proofing compound shall be measured and paid for separately as \"Supply Only\" |
| 11 | M&L Acrylic emulsion polymerof acrylic single component low viscosity polymer for preventing leakages over exisitng/New surface of slab, terrace, exterior, interior wall, Chajjas etc as per following procedure :-(a) Surface & surface preparation : Remove all the loose particles , dirt & dust clean by water , wire brush & mechanical cleaning , grease & oil should be cleaned using solvents. If the surface is previously coated with tar, it should be thoroughtly scraped off.The surface should be dry before application .All the cracks and crevices in the concrete slab to be filledwith polyurethene based sealent with and including application of PU based primer all as directed by Engr-in-Charge.(b) Finish paint : Apply water based polyurethenene modified dispersion (single component cold applied ,non toxic,VOC complaint)in 03 coats icluding 01 coat of primer of same materials after dillution of water at 50 % or specific primer matching same material as per manufacturers specificationand as dircted by EIC/GE Make:-Bostic,Berger,Fosroc,Sika,Asian,or any other make approved by E-in-C\"sBranch for PU based water proofing treatment. |
| 12 | M & L for Roughening surfaces of old concrete floor by picking sweeping cleaning & washing down with water to remove dust etc incl removal of old treatment of any description and applying one coat of neat cement slurry @ 3.00 Kg/Sqm complete all as directed by Engr-in-Charge. |
| 13 | Demolition of cement concrete of any description and inany position and removal of debris out of MOD land complete all as specified and directed. |
| 14 | M&L15mm thick screed in CM 1:4 on floor mixed with water proofing compound @ 3% by weight of cement & finished even and smooth without using extra cementand applying two coats of Roff Hyguard eX Rezone chemicals or equivalent make complete all as specified and as directed. |
| 15 | M & L for cement concrete1:5:10type C2 (using 40 mm graded brick aggregate) as for filling in sunken floor all as specified and directed by Engr-In-Charge |
| 16 | M & L forcement concrete 1:2:4 type B-0 (using 12.5mm graded stone aggregate) as in floor levelling course and in similar situations 25mm thick complete all as specified and directed. |
| 17 | Supply only integral water proofing compound for roof and sunken floor complete all as specified and directed. |
| 18 | Demolition of Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work cement concrete is reinforced (reinforcement cut as required to facilitate demolition) complete all as specified and directed. |
| 19 | M&L for reinforced cement concrete type B1 1:2:4 (using 20 mm graded stone aggregate) for slabs supported on walls, beams landings, balconies, deck slabs and in shelves and the like including necessary form work complete all as specified and directed. |
| 20 | M&L for TMT bars 8 mm dia cut to length bent to shape required including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire not less than0.9 mm dia complete all as specified and directed. |
| 21 | Demolition of Brickwork or stone masonary built in cement mortar inlcuding all quions, arches, pillars etc. but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed. |
| 22 | M&L for brickwork with flyash bricks, modular, straight or curved on plan to any radius ex 6m mean radius,built in CM 1:6 complete all as specified and directed. |
| 23 | M&L for 100 mm thick Hardcore(broken stone or boulders) of gauge not exc. 63mm deposited, spread and levelled in layers not exc. 15cm thick watered and rammed to a true surface complete all as specified and directed. |
| 24 | M&L for 100 mm thick PCC 1:2:4 type B2 (using 40mm graded stone aggregate) as in floors, subbase complete all as specified and directed. |
| 25 | M&L for 75mm thick PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in plinth protection complete all as specified and directed. |
| 26 | Taking down cement plaster, any description on brick, concrete or stonewalls or ceiling including racking out joints, hacking for key, scrubbing down with water etc and removal ofrubbish off all as specified and directed. |
| 27 | M&L for Rendering 15 mm thick in two layers, 5mm thick over 10 mm thick on brick masonary work/concretesurfaces in cement mortar 1:4 finished surfaces even and smooth without using extra cement, complete all as specified. |
| 28 | M&L for Rendering 10 mm thick on brick /stone masonry/concrete surfaces in cement mortar 1:6 finished even and smooth without using extra cement, complete all as specified. |
| 29 | M&L for Rendering 5 mm thick on concrete surfaces in cement mortar 1:3 in ceilings complete all as specified. |
| 30 | M&L preparing surfaces of new plastered surfaces and and applying two coat of cement base paint over a coat of primer complete all as specified and directed |
| 31 | M&L forthree coats of white wash on new surfaces of ceiling complete all as specified and directed. |
| 32 | M&L forpreparing surfaces of new plastered surfaces and and applying three coats of whitewash on walls complete all as specified and directed |
| 33 | M&L forcomplete removal of existing treatment and applying three coats of whitewash on walls complete all as specified and directed |
| 34 | M&L forcomplete removal of existing treatment and applying three coats of white wash on ceilings complete all as specified and directed |
| 35 | M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with & over 15 mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 36 | M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with & over 10mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 37 | M&L for Non Skid Ceramic coloured tiles 7 to 8mm thick area of each tile exceeding 0.06 Sqm but not exceeding 0.11Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over with and including 15mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 38 | M&L Glazed ceramic coloured tiles in vertical surfaces 300mm x 450mm x 7mm as in dado/skirting etc. and joineted neat in cement slurry and pointed in white or colour cement to match over with and including 10mm thick screed bed in CM 1:4 complete all as specified and directed. |
| 39 | M&L Machine cut mirror polished kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including 15mm thick screed bed in CM 1:6complete all as specified and directed. |
| 40 | M&L Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed andjointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing and including 10mm thick rendering in CM 1:4 complete all as specified and directed. |
| 41 | M&L Machine cut cudappah stone slab 20-25mm thick with & over 20mm cement screed base in CM 1:6 laid and jointed with grey cement slurry mlixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed. |
| 42 | Rounding to one edges of stone slabs complete all as specified and directed. |
| 43 | Taking down chowkats or frames of wooden or steel exc 1.5 sqm & n.exc. 4 Sqm with Shutters (without taking off shutters from the frames) complete all as specified and directed. |
| 44 | Taking down chowkats or frames of wooden or steel window/ventilator not exc 1.5 sqmwith Shutters (without taking off shutters from the frames) complete all as specified and directed. |
| 45 | S&F solid PVC frame (single rebated) of size 60mm x 30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheet metal CSK screws complete all as specified and directed.Note:- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life. |
| 46 | S&F factory made solid PVC profiled panel door shutter 28mm thick with integral skin as frame & 3mm thick high pressure compact laminate on both side of approved colour as infill, with \"C\" type GI or 40x 20x 19 of MS pipe as stiffner and supplying and fixing in frame at site complete all as specified and directed. |
| 47 | M&L for pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc complete all as specified, supplied and fixed size 125X60mm ccomplete all as specified and directed. |
| 48 | M&L for pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc complete all as specified, supplied and fixed size 105X60mm ccomplete all as specified and directed. |
| 49 | M&L for PCC 1:3:6 type C-0 (using 12.5mm graded stone aggregate) as in filling steel frames etc. incl necessary form work complete all as specified and directed. |
| 50 | M&L for 40mm thickFlush shutters with lipping all around of solid core construction with block board core and ply wood face panels commercial type on both side complete all as specified and directed. |
| 51 | M&L for factory made 35mm thick 2nd class H/wood Guazed and skeleton shutters, open rebated and prepared to receive 12mm thick toughened glass, gauge etc. (with sash bars) edges of ramming plain, chamfered or rounded, fitted with cut of and mitred beads for securing glass, gauge etc of size of members of shutters as specified in SSR Part-I section 8 clause No. 8.2(a) and fitted to chowkats complete all as specified and as directed. |
| 52 | S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed. |
| 53 | S&FSteel ventilators with centre hung shutter including hinges, steel peg stay, complete. complete all as specified and directed. |
| 54 | M&L for 4mm thick figured glass, pin head type and glazing with not exc.0.5 Sqm in each pane to aluminium frame work for ventilators complete all as specified and directed. |
| 55 | S&F sheet glass 3 mm thick ordinary glass with oil putty not exceeding 0.50 Sqm in each pane, including putty glazing clips complete all as specified and directed |
| 56 | S&F in repairs stainless steel wire cloth 0.36mm nominal dia wire & average width of aperature 1.18mm complete all as specified and directed. |
| 57 | S & F for 100mm butt hinges, castbrass, with mild steel hinge pin, bright polished and fixed, type B-12 complete all as specified and directed. |
| 58 | S&FAluminium alloy anodised sliding door bolt with hasp, staple 300 mm long of cast extruded section cast aluminium alloy complete all as specified and directed. |
| 59 | S&FAluminium anodised barrel tower bolt 150 mm long of extruded section cast aluminium alloy complete all as specified and directed. |
| 60 | S&FAluminium anodised barrel tower bolt 100 mm long of extruded section cast aluminium alloy complete all as specified and directed. |
| 61 | S&FAluminium handles, cast typeanodised 150 mm long of extruded section cast aluminium alloy complete all as specified and directed. |
| 62 | S&FAluminium handles, cast typeanodised 100 mm long of extruded section cast aluminium alloy complete all as specified and directed. |
| 63 | S&F in repairs 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed. |
| 64 | M&L for floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring complete all as specified and directed. |
| 65 | Dismantling structural steel work including doors, gates,grill but excluding framed truss etc complete all as specified and directed. |
| 66 | M & L for mild steel framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 Gde -E-165 complete all as specified & directed |
| 67 | M&L for Two coats of synthetic enamel paint over a coat of red oxide on new steel surfaces exc 10 cm width or girth etc incl preparation of surfaces complete all as specified and directed. |
| 68 | M&L for Two coats of synthetic enamel paint over old steel surfaces exc 10 cm width or girth etc incl preparation of surfaces complete all as specified and directed. |
| 69 | M&L Preparation of wooden Surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of Synthetic enamel paint over a coat of pink primercomplete all as specified and directed. |
| 70 | S&F for steel water tubes, 20mm bore medium grade, galvanized with all fittings and fixed complete to walls, ceiling or laid in floor, complete including taking up or down steel tubing and connections or removal to store complete all as specified & directed. |
| 71 | All as per item No. 70.00 here in before but 15mm complete all as specified & directed. |
| 72 | M&L for cutting chases, pinning in stone, concrete block walls making good to facings where required and pointing in cement mortar 1:3 to concealed water tubingand making good complete all as specified and directed. |
| 73 | S&F1000 ltrs capacity, Rotational moulded polythylene water storage tank (cylindrical vertical with closed top) hoisted and in position including ball brass valve 25mm high pressure with polythene float and fly nut complete including dismantling of existing U/s water tank and removing to store complete all as specified and directed. |
| 74 | S&F in repairs Gun metal globe or gate valve with iron wheel head screwed both ends size 20mm for iron pipe, fixed complete all specified. |
| 75 | S&F in repairs vitreous China squatting pan “ORISSA” pattern size 580mm X 440mm, white with P or S trap front or back inlet with integral foot rest (excl flushing cistern & flush pipe) &including connection to trap & to flushing pipe anti syphonage pipe etc complete including making good to floor,10 ltrs PVC valveless , syphonic action type low level flushing cistern with inlet , ball valve, float & handle and flush pipe and connection to drain (or outgoing pipe) and to flushing pipe, anti -syphonage pipe, etc., completeall as specified and directed. |
| 76 | S&F 15 mm dia CP Bib taps, cast copper ally with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed all as specified & directed |
| 77 | S&F in repairs chromium plated brass shower rose 125 mm dia with swivel joints complete all as specified and directed |
| 78 | S&F in repair angle/stop valvescast copper alloy, screwed down high pressure fancy type chromium plated 15 mm dia complete all as specified and directed. |
| 79 | S&F in repair angle/stop valves cast copper alloy, screwed down high pressure fancy type chromium plated 15 mm dia with long shank and cup (concealed type) all as directed by Engr-in-Charge |
| 80 | S&F in repair Wash hand basin, vitrous china, coloured flat back of size 550 x 400mm encluding cutting for and pining in ends of brackets or erecting stand including brass waste coupling waste pipe, 15mm dia bore pillar taps, cast copper alloy chromium plated fancy type fixed complete all as specified and as directed. |
| 81 | S&F in repairs Brass chromium plated Tubular towel rail 20mm dia D type, 60cm long between flanges complete all as specified and directed. |
| 82 | S & F in repairs for 100mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed. |
| 83 | S&F in repairs stainless steel grating dome 125 mm dia complete all as specified & directed by Engr-In-Charge |
| 84 | S&F in repair sinks made of stainless steel 1mmthickkitchen with plugs, washers and waste coupling; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm including waste pipe complete complete all as specified and as directed. |
| 85 | Demolition and breaking up drain pipes (Salt glazed ware, PVC, AC or Reinforced concrete) set in cement mortar 100mm and below complete all as specified and directed. |
| 86 | S&F PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to wall, floor of size 110mm bore complete all as specified and directed. |
| 87 | S&F PVC (SWR) pipes, single socketed in any length with rubberring joints fixed to wall, floor of size 75mm bore complete all as specified and directed. |
| 88 | S&F PVC (SWR) pipes, single socketed in any length with rubber ring joints laid in trenches or in floors, floor of size 110mm bore complete all as specified and directed. |
| 89 | S&F PVC (SWR) pipes, single socketed in any length with rubberring joints laid in trenches or in floors, floor of size 75mm bore I complete all as specified and directed. |
| 90 | S&F in repairs PVC (SWR) 110 mm bore junction, single(single \"T\")equal or unequalprovided with access door complete all as specified and directed. |
| 91 | S&F in repairs PVC (SWR) 75 mm borejunction, single(single \"T\")equal or unequalprovided with access door complete all as specified and directed. |
| 92 | S&F in repairs PVC (SWR) bends with access doors 110 mm bore complete all as specified and directed. |
| 93 | S&F in repairs PVC (SWR) bends of any radius 75 mm bore complete all as specified and directed. |
| 94 | S&F PVC (SWR) branch piece, single (single Y) equal or unequal 110mm bore complete all as specified & directed. |
| 95 | S&F PVC (SWR) branch piece, single (Single Y) equal or unequal 75mm bore complete all as specified & directed. |
| 96 | S&F PVC (SWR) branch piece, double (double Y) equal or unequal 75mm bore complete all as specified & directed. |
| 97 | S&F PVC (SWR) vent cowl 110mm bore complete all as specified & directed. |
| 98 | S&F PVC (SWR) vent cowl 75mm bore complete all as specified & directed. |
| 99 | S&F PVC (SWR) gully traps 125/100mm setting and jointed in cement solventcomplete all as specified & directed. |
| 100 | (E&M PORTION)Taking down carefully aluminium / copper point wiringcomplete (light, fan socket & power) including unserviceable fixtures and fittings such asswitches ceilimg roses pendents regulators sockets light fittings etc completeremoving materialfor taking credit & making good disturbed wall / floor etc complete all as directed by Engineer-in-Charge |
| 101 | Taking down sub main wiring complete including fitting and fixtures, removing materials for making good disturbed surfaces of walls, floors, roof etc, all as specified and as directed. |
| 102 | Taking down carefully unserviceable DBs any type/size With MCCBs/MCBs//Isolator etc and disconnecting and making good disturbed surfaces complete all as directed. |
| 103 | M&L Point wiring complete with 1.5 sqmm single core PVC insulated andunsheathed cable 1100 volts, FRLS grade with multistranded copper conductor ISI marked drawn throughconcealed heavy duty PVC conduit fixed in walls / roofs / floors / ceiling etc. and including provision of PVC conduit, 1.5 sqmm stranded copper conductor cable as earth continuity conductor and connected to common earth dolly including concealed MS box with 3 mm thick laminated sheet cover fixed with brass screws and cup washers for mounting of plate mounting for housing the switches, socket outlets, fan regulators etc for one Light / Fan Point / Bell point controlled by one switch complete all as specified and as directed. NOTE:- Cost of cutting chases & making good disturbed surfaces to match existing surfaces shall deemed to be included in quoted rate. |
| 104 | (a) One light point controlled by one way switch. |
| 105 | (b) One fan point controlled by one way switch. |
| 106 | (c) One light point controlled by Two way switch. |
| 107 | (d) One 3 pin switch socket outlet point 5 Amps on independent board. |
| 108 | (e) One 3 pin switch socket outlet point 5 Amps on same board with other switch. |
| 109 | S & Fix switch piano, flush type single pole, one way 5 Amps capacity complete all as specified and directed. |
| 110 | S & Fix switch piano, flush type single pole, two way 5 Amps capacity complete all as specified and directed. |
| 111 | S & Fix switch piano, flush type single pole, one way 15 Amps capacity complete all as specified and directed. |
| 112 | S & Fix socket out let 6A 2/3 on combined 2 module complete all as specified and directed. |
| 113 | S & Fix Ceiling rose surface backlite 65x50mm 3 terminals complete all as specified and directed. |
| 114 | S&Fixfan regulator electronic 2 modular type volts AC 50 HZ ,300 Watts,4 step complete all as specified and directed. |
| 115 | S & Fix Batten General purpose industrial compact batten suitable for single or twin LED Tubelight with integral LED driver, available in single / double side connection CRCA batten suitable for mount LED tube rod 1 x 18 watts including necessary electric connections 3 core 1 sqmm insulated copper wire from ceiling rose to tube light fitting complete all as specifed and directed by Engineer-in-charge. |
| 116 | S & Fix LED Tubelight (single side connection)very high efficacyfor installation in existing tubelight luminaire with G13 lamp holders to give glare free light with necessary fixing arrangement etc complete all as specifed and directed by Engineer-in-charge. |
| 117 | S&F LED Tube light fitting 10 watt, 230 volts, sleek and seamless profiled extruded aluminium batten with an efficient diffuser to illuminate work and retail spaces complete with all accessories all as specified & directed by Engr-in-Charge. |
| 118 | S&F 10W LED Bulk Head for outdoor and indoor areas in perfect synchronization with functionality and aesthetics complete with all accessories all as specified & directed by Engr-in-Charge. |
| 119 | Supply and Fix, wall mounting fitting, suitable with 9 W LED including suitable lamp complete all as specified and directed. |
| 120 | S & Fix 30 Watts LED new generation energy saving and environmental friendly long life LED building light made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having Bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK08 along with GI bend of suitable size. Make Havells : ENDURASUNDOWN or equivalent in Philips/Wipro /Crompton as approved. |
| 121 | S&Fix MCB DB ETPN8 ways,with metal double door ,IP -43 protection suitable for MCCB as incommer and MCB as out going,VTPN DB\"s 415 volt 3 phase complete with appropriate size copper bus bar and neutral link as required at site and including cutting chases to wall for fixing of DB and making good distrubed wall/surface all as required at site etc complete all as specified and directed. |
| 122 | Supply and fixing ceiling fans complete with blades, down rods and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. |
| 123 | Supply and fixing 415V 10KA \"C\" curve miniature circuit breaker (MCB) TPN of 40 A to 100 Amps current carrying capacity in the DB complete all as specified and directed. |
| 124 | S & Fix of RCBOs for earth leakage, overload and short ciruit protection, fourpole, 30mA, 6A to 32 A complete all as specified and directed. |
| 125 | S & Fix double door sheet metal enclosure distribution board SPN, 4 ways 240 volts, with 200 amps rated bus bar, with IP 43 protection and double door, suitable for mounting MCBs including taking down old MCB DB etc complete all as specified and as directed |
| 126 | S & Fix of MCB single pole and neutral, 240 volts, 6 to 40 Ampere, rupturing capacity 10 KA, ‘C’ series complete all as specified and directed. |
| 127 | S & Fix of MCB single pole, 240 volts, 6 to 40 Ampere, rupturing capacity 10 KA, ‘C’ series complete all as specified and directed. |
| 128 | S & Fix sheet metal enclosure distribution board SPN DB\"s 2 way with MCB complete all as specified and directed. |
| 129 | M & L for submain wiring alongwith earth wire with the following sizes of FRLSPVC insulatedcopper conductor single core cable , multistrandedon the surface through and including suitable size ofPVC casing and cappingwith its accessories all as specified and directed by Engr-in -charge for the following:- |
| 130 | (a) 2x1.5 sq mm and 1x1.5 sq mm as earth wire |
| 131 | (b) 2x6.0 sq mm and 1x6 sq mm as earth wire |
| 132 | Taking down the existing electric meter of Single Phase any capacity and make after disconnecting electrically and carry out the cleaning and refixing, reconnecting including applying one coat of paint on existing ms box of electric meter testing in all respect fo smooth running complete all as directed by Engr -in charge. |
| 133 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 4 core complete all as specified and directed. |
| 134 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth and getting out in Soft / loose soilincluding forming bottom surface etc complete all as specified and directed. |
| 135 | Returning, fillingin including spreading, levelling ,watering and well ramming in layers not exceeding 25 cm thick in soil complete all as specified and directed. |
| 136 | Removing excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 50 mtr above the starting point complete all as specified and directed. |
| 137 | Supply & Laying 50 mm outside dia double wall corrugated pipe (DWC) of HDPE ISI Mark for enclosing cable below ground / road surface, to a required depth, including suitable size coplers for jointing of pipe all as per site requirement complete all as specified and directed. |
| 138 | M &Lfor GI pipe of 50mm dialight grade for road crossing / on wall / on pole for cableprotection complete all as specified and directed. |
| 139 | M & L Earthing complete with galvanised steel earth plate electrode 60x60cmx06mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed. NOTE:- Cost of earth lead and protection pipe upto 7.5M shall deemed to be included in quoted rate. |