Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 03-10-2023 | Date Corigendum | Date | 09-10-2023 |
| 2 | 26-09-2023 | CSD | Other | 03-10-2023 |
| Sl. No. | Item Description |
| 1 | Dismantling flat wooden or A.C. Sheet ceiling with frame work including stacking the materials as directed with all leads, lifts etc. complete. |
| 2 | Removing wooden or A.C. partition including frame work and stack-ing the materials as with all leads, lifts etc. complete. |
| 3 | Removing doors and windows with frames and stacking the materials as directed with all leads, lifts etc. complete. |
| 4 | Removing urinal pans or wash hand basins with frame including disconnecting the sanitary and water supply connections, removing the same carefully and stacking the serviceable materials as and where directed including throwing the unserviceable materials outside etc complete. |
| 5 | Removing W.C. pans including disconnecting the sanitary and water supply connections, removing and breaking flooring and bed con-crete around pan removing the same carefully and stacking the serviceable materials as adn where directed including throwing the unserviceable materiasls out side etc. carefully and throwing out the refusal outside etc. complete. |
| 6 | Removing brick bat coba including stacking the spoils as directed with all leads, lifts etc, complete. |
| 7 | Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete |
| 8 | Removing iron pipe raling having wooden R.C.C. or C.C. or iron post and stacking the materials as directed etc. complete. |
| 9 | Dismantling brick masonry in lime or cement mortar and stacking the materils as directed with all leads, lifts etc. |
| 10 | Lowering down the debris obtained from breaking and removing the cement plaster / burnt brick masonry of the first floor by any means without causing dust nuisance and damage to structure, stacking the same as and where directed including cleaning the site complete. |
| 11 | Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. complete |
| 12 | Providing and laying cement concrete flooring 50mm thick with M20 cement concrete laid to proper level and slope in alternate bays including compaction, filling joints, marking lines to give the appearance of tiles of 30cm x 30cm or other size laid diagonally/ square etc. finishing smooth (with extra cement) in any colour as directed and curing etc. complete. With Natural Sand |
| 13 | Providing and constructing masonry in Autoclaved Areaclaved (Celluar) Concrete Block of aproved manufacturer confirming to IS 2185 Part III 1984 of size (625x240x225) mm in extra fine jointing mortar of fixoblock of Ultra Tech or equivalent in superstructure including, striking joints, racking out joints watering and scaffolding etc. complete |
| 14 | Providing waterproof plaster in W.C. and bath 20 mm thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of 1 kg. per bag of cement of approved make and manufacturer and curing (and filling joints of Nahani trap and any outlet by properly) etc. complete. |
| 15 | Providing waterproofing in W.C. and bath including brick bat coba in all position including providing and laying 12mm bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @ 1kg/per bag of cement laying brick bat coba of required thickness in cm 1:5 with waterproofing compound 1 kg/bag of cement grouting and finishing the top layer with 20mm thick brick bedding in cm mortor 1:3 with waterproofing compound 1 kg/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years\" guarantee on requisite stamp paper including curing etc. complete. |
| 16 | Providing structural steel work of rectangular hollow steel section for steel trusses, other similar trussed items like purlin and members with all bracing, gusset plates etc. as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted/bolted/ welded connections and one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade complete.Spec. No. : As directed by Engineer-in-charge. |
| 17 | Waterproofing Treatment to new Toilet/bathroom by using Polymeric Cementitious Membrane as approved by Engineer in charge, followed by 112mm thick brick bat coba covered with 20 mm mortar finish. If there are cracks on the bare slab, open the crack in V Groove and fill it with ready to use repair polymer modified mortar based on special cements, aldehyde based polymers with thixotropy modifying agents. If there are lots of honeycombs and identified bad patches of concrete the same should be grouted as per the instructions of site incharge. (The grouting shall be paid separately). Clean the entire surface thoroughly and over this prepared surface, apply three coats of polymeric Cementitious waterproofing coating having a non-toxic, 2-(methoxycarbonyl)-1-propene-Butyl-2 propenoate (MPBP) based polymeric waterproofing solution as approved by Engineer in charge. Provide and lay 112 mm average thicknes of brick bat coba in cement mortar 1:5 over 12mm thick CM 1:3 bedding with one pouch of 330 grams of thorough blend of special cements, aldehyde based polymers, shrinkage compensating agents as approved by Engineer in charge per 50 Kg bag of cement and finishing with 20 mm thick cement plaster in cement mortar 1:3 by mixing one 330 grams pouch of above admixture per 50 Kg bag of cement, including all lead, lifts and laid to proper slope to drain off water entirely preparing bell mouth including watta, beveled or champhered portion at the junction of wall and work up to a height of 300 mm or as directed and including finishing the top layer of waterproofing treatement with false marking of 30 cm x 30 cm or as directed, curing and covering the whole treatment. MPBP Polymeric Waterproofing Coating for Concrete and Masonry should have following minimum properties:1) Elongation % (ASTM D412-2016): @ 100% 2) Tensile Strength N/mm2 (ASTM D412- 2016): 3.3 3) Specific Gravity: 1.02 ± 0.02 4) Total Solids (ASTM D1644-2012): 43.98 5) Hardness Shore A (ASTM D2240-2015): 82 |
| 18 | Providing and fixing mild steel grill work for windows, ventilators etc. 20 kg/sqm as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. |
| 19 | Providing and fixing in position U.P.V.C.(Unplasticized Poly Vinyl Chloride) having multi-chambered outer frame section (73 x 50)mm with an outer wall thickness of 2mm & steel reinforcement, multi-chambered slider frame (73x 60) mm with steel reinforcement, multi-chambered slider sash (46x 82) mm with steel reinforcement designed to give optimum strength, 5 mm thick toughened double glass with 12 mm spacer of good quality including alluminium track, Inter-locking profile, coextruded beadings, EPDM gaskets,silicon sealent,sliding handle, fixtures and fastenings (couplings, hinges) including with all required screws and nuts with all necessary U.P.V.C. sections as per the detailed drawing and as directed by Engineer-In-Charge etc. complete. |
| 20 | Providing and laying telephone black / Amba White / Cadbury brown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etc.complete. |
| 21 | Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. |
| 22 | Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete. |
| 23 | Providing and fixing Italian marble in flooring as approved using 18mm thick gang saw machine cut stone at all levels, of required size & pattern and of approved shade, color and texture laid using white cement slurry over 20 mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) followed by laying, fixing and jointing with white cement slurry mixed with matching pigment, including rubbing, curing, polishing, making mouldings of approved profile and polishing of mouldings and edges to give high gloss finish etc, complete at all levels and as per direction of E-I-C. |
| 24 | Providing and fixing Vertical Italian marble for Cladding as approved using 18mm thick gang saw machine cut stone at all levels, of required size & pattern and of approved shade, color and texture laid using white cement slurry over 20 mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) followed by laying, fixing and jointing with white cement slurry mixed with matching pigment, including rubbing, curing, polishing, making mouldings of approved profile and polishing of mouldings and edges to give high gloss finish etc, complete at all levels and as per direction of E-I-C. |
| 25 | Anti Skid Vitrified Tiles Flooring : Providing and laying vitrified mirror / glossy finish tiles decorative type having size 600 mm x 1200 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 (group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. |
| 26 | Providing and laying vitrified mirror / glossy finish tiles having size 600 mm x 1200 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 (group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete |
| 27 | Providing and fixing 1.05 meter height Railing with Acrylic solid surfaces finished handrail and decorative M.S. powder coated supports with antique design including bevwlling glass using Acrylic solid surfaces finished HDDF frame as per detail drawing and using 50mm x 50mm M.S. powder coated vertical support and flat for fixing with necessary hardware as per design etc. complete. |
| 28 | Providing and laying in trenches 25 mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 29 | Providing and laying in trenches 20 mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 30 | Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete |
| 31 | Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. |
| 32 | Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 mm x 450 mm size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 mm thick supports with kadappah top 35 to 40 mm thick and polished granite 16 to 20 mm top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 cm height and top granite of 75 x 40 cm including cutting, opening for sink of required size in kadappah as well as granite etc. complete. (Platform top size 5.00 m x 0.60 m and height is 0.75 m) |
| 33 | Providing and fixing white european type wall-hung pan, of size 350mm x 355mm x 570 mm concealed flush tank with floor-mounting frame installing kit and drain pipe connection set for wall hung WC, with approved make square control plates including soil pipe, vent pipe upto the outside face of wall, 100mm dia C.I. plug bend inlet pipe all fittings,cutting & making good walls, floors etc. complete. |
| 34 | URINAL Providing and fixing white glazed Jaquar or equivalent make Urinal of 5 litres capacity with fitting, inlet pipes and stop tap brackets for fixing the cistern 32mm dia P.V.C. flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap soil pipe connec-tion upto the outside face of the wall. |
| 35 | Providing and fixing 10 cm C.I. Nahani Trap including C.I. grating bend and piece of C.I. pipe upto the outside face of the wall complete. |
| 36 | Providing and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets/union nut etc. complete. |
| 37 | Providing and fixing C.P. 2-way BIB cock of kolher or equivalent with wall flange including necessary sockets/ union nut etc. complete |
| 38 | Providing and fixing sink cock with regular swinging spout (Wall Mounted Model) with wall flange with approved make incluidng other necessary fitting, etc. complete as directed by Engineer in charge. |
| 39 | Providing and fixing stainless steel sink of size 600 x 510 x 200 mm incluidng coupling, outlet pipe, elbow and other necessary fitting, finishing etc. complete. |
| 40 | JET Spray Providing and fixing stealth faucet jet spray of approved Jaguar or equivalent make including necessary sockets/ union nut etc. complete |
| 41 | Providing and fixing Table top white wash basin of size 120x635x405mm rubber plugs and brass chain, with pillar cock, C.P.Angular stop cock long thread, continental including S.S. bottle trap of approved make having necessary pipe connection up to theoutside face of the wall.etc complete as directed by Engineer in charge. |
| 42 | BlankSOAP DISPENSOR - Providing and fixing wall mounted soap dispensor of Kolher or Equivalent approved make and design. Item include necessary sockets/ union nut etc. complete |
| 43 | Side Storage :Providing and fixing side storage units with Acrylic soild surfaces Top using 18 mm thick Marine ply ISI 710 with antitermite complying with IS:710 at top,bottom,sides,drawers and shutters also and teakwood lipping and moulding of edges.Exposed faces to be finished with 4 mm thick veneer and 1mm thick Internal laminate for internal surfaces with melamine polishing including all necessary hardwears such as brass hinges,telescopic channel handles,locks as per the design and as directed by the Engineer in charge etc.Complete. |
| 44 | Wall Panelling :Providing and fixing Wall panelling with 18 mm HDHMR Thermo treated ( Formulation recommended by Manufacturer)Pre-Laminated Panel using 50mmx50mmx1.5mm Natural Anodised Aluminium frame with vertical and horizontal having centre to centre distcance of 600mmx600mm, filled with rigid Polywool of 1500 GSM. MLV Anti Moisture and anti Sound Transfer characterisitics. HDHMR PANEL should be fixed with 4mm Groove supported by SS \"F\" Profile. Completed as per detail drawings and as directed by the Engineer In-charge etc. Complete. |
| 45 | Providing and fixing Wall panelling with Acoustic fluted-Soundtrap Indosonic Slat Panel using 16mm Acoustic Wooden Soundtrap Slat Panels of size 2400mm x1200mm, made of HDHMR , Thermo treated (formulation recommended by Manufacturer)Panel, substrate of FR grade, with a Laminated facing as per the approved shade/ species & finish and a melamine balancing layer on the reverse side. The Panels should have a special Helmholtz perforation pattem on the reverse side of the panel and the pitch, grooves design on the front side will be as per the Architects / Engineer In-Charge requirement. The edges of the panel should be tongue-grooved pattern for fixing and getting a seamless surface finish. The back surface of the panel should be provided with high quality acoustic fleece. The panels shall be mounted and fixed on the Z-Bar/Strut channel with clipping system. The Z-Bar/Strut Channel should be fixed on MF5 Section for plumb and Levelling of the Acoustic Panel.The product should have an acoustical performance of 0.85 NRC |
| 46 | Wall Panelling:Providing and fixing Wall panels with 4mm Acrylic sheet over 18 mm HDHMR Panel Thermo treated ( Formulation recommended by Manufacturer) Panel using 50mmx50mmx1.5mm Natural Anodised Aluminium frame with vertical and horizontal having centre to centre distcance of 600mmx600mm, filled with rigid Polywool of 1500 GSM. MLV Anti Moisture and anti Sound Transfer characterisitics. HDHMR PANEL should be fixed with 4mm Groove supported by SS \"F\" Profile. Completed as per detail drawings and as directed by the Engineer In-charge etc. Complete. |
| 47 | Providing and fixing Wall panelling with Acrylic Sheet using 18 mm thick HDHMR Panel, Thermo treated (formulation recommended by manufacturer) with vertical supports of 25mmx25mmx1.2mm thick size Anodised Aluminium Frame. It should be covered with 10 mm thick HDHMR Panel and external side to be finished with 1 mm thick Acrylic Sheet with wooden beading grove and completed as per detail drawings and as directed by the Engineer in charge etc.Complete |
| 48 | Providing and fixing in position Acoustical Fabric Standard Indosonic Wall Paneling of size 600X600/ 600X1200 mm, with square edges made of rigid Fibre glass substrate 25mm thick (48 kg/m3 Density) with recycle content of 85% & high quality Acoustic Fleece and wrapped on the front side with an acoustically transparent and breathable fabric stretched over Aluminium extruded profile frame for seamless alignment and stability. The panel shall be classified for Fire Retardant grade as per BS EN1021 and IS-1561-2002 and should have Hydroguard property for water & stain repellency and Abrasion value of around 90000 cycles, with an option of colors, size, dimensions, etc – as per the design and choice of the Architect/Engineer in charge, giving an average sound absorption level of 0.85 NRC. INSTALLATION: The vapour barrier membrane (recommended by manufacturer) shall be mounted on the vertical surface of the wall before the installation of the Aluminium framework. The Anodised Aluminium framework of 50x50mmx1.5mm shall be fixed with suitable isolator, with an air gap of 50mm (as per recommended by manufacturer). Anodised Aluminium hollow space section should be filled with Polyurethane sound resistance chemical. The Framework will be in-filled with 25mm thick RGB of density 48 Kg/m3 one side and on the inner side with chicken wire mesh/2mm Fleece. The framework shall be placed at 600mm x 600mm c/c both ways and 12mm marine Ply with Helmholtz perforation shall be fixed on the frame. The fabric panel is to be affixed with Wall panel impalers/Z-Bar and proprietory adhesives as per the instructions laid down by the manufacturer, including scaffolding, etc. Construction, adhesives and accessories shall be as per the instructions laid down by the manufacturer, including scaffolding and removing the same if required. |
| 49 | Providing and fixing in position Acoustical Fabric Standard Indosonic Wall/floor/Slab Paneling of size 600X600/ 600X1200 mm, with square edges made of rigid Fibre glass substrate 25mm thick (48 kg/m3 Density) with recycle content of 85% & high quality Acoustic Fleece and wrapped on the front side with an acoustically transparent and breathable fabric stretched over Aluminium extruded profile frame for seamless alignment and stability. The panel shall be classified for Fire Retardant grade as per BS EN1021 and IS-1561-2002 and should have Hydroguard property for water & stain repellency and Abrasion value of around 90000 cycles, with an option of colors, size, dimensions, etc – as per the design and choice of the Architect/Engineer in charge, giving an average sound absorption level of 0.85 NRC. INSTALLATION: The vapour barrier membrane (recommended by manufacturer) shall be mounted on the vertical surface of the wall before the installation of the Aluminium framework. The Anodised Aluminium framework of 50x50mmx1.5mm shall be fixed with suitable isolator, with an air gap of 50mm (as per recommended by manufacturer). Anodised Aluminium hollow space section should be filled with Polyurethane sound resistance chemical. The Framework will be in-filled with 25mm thick RGB of density 48 Kg/m3 one side and on the inner side with chicken wire mesh/2mm Fleece. The framework shall be placed at 600mm x 600mm c/c both ways and 12mm marine Ply with Helmholtz perforation shall be fixed on the frame. The fabric panel is to be affixed with Wall panel impalers/Z-Bar and proprietory adhesives as per the instructions laid down by the manufacturer, including scaffolding, etc. Construction, adhesives and accessories shall be as per the instructions laid down by the manufacturer, including scaffolding and removing the same if required. |
| 50 | Providing & fixing Rigid Polywool wadding of approved Indosonic make, shade and pattern of 1000 GSM 50mm thick to be fixed using Propriatary Adhesive for fixing all as per design, shade & make of apporved by Engineer-in-Charge. |
| 51 | Providing and fixing in position of Acoustic Parquet Type Wooden Indosonic Ground Flooring made from Imported engineered wooden planks with Tongue and groove fixing arrangements, Pre-laminated front & moisture resistance coating at lower ends of 6mm thick x150mm width x 1200mm length size, fixed on the available Frames of Stage platform floor by proprietary adhesive (recommended by manufacturer) over sandwiched 5 mm Hitlon Vapour Barrier / Moisture resistance Mat between Wooden planks and true ground floor. The Engineered Wooden Panels should be highly resistance to humidity (RH: 99%), water vapour diffusion resistance (as per ISO-12572-2016 standards), zero mold growth (as per EN-15101-1 standards), highly versatile and (Class A) flame retardant (as per BS-3119 standards, IS-15061 standards) and Thermal conductivity (as per EN12667 standards). Floor Panels colour should be as per approval from the Architect/Engineer in charge. |
| 52 | Providing and laying in position Three layes Parquet / Engineered Wooden flooring having plank size of 135mm to 210mm wide, 1800 to 2420mm long of 15mm thick with approved veneer on top including all necessary jointing and core material as per detailed drawings & design etc. with Tongue and groove fixing arrangements, Pre-laminated front & moisture resistance coating at lower ends of 6mm thick x150mm width x 1200mm length size, fixed on the floor by proprietary adhesive (recommended by manufacturer) over sandwiched 5 mm Hilton Vapour Barrier / Moisture resistance Mat between Wooden planks and true ground floor. The Engineered Wooden Panels should be highly resistance to humidity (RH: 99%), water vapour diffusion resistance (as per ISO-12572-2016 standards), zero mold growth (as per EN-15101-1 standards), highly versatile and (Class A) flame retardant (as per BS-3119 standards, IS-15061 standards) and Thermal conductivity (as per EN12667 standards). Floor Panels colour should be as per approval from the Architect/Engineer in charge. complete. Spec. As directed by Engineer in charge. |
| 53 | Providing and fixing in position Gypsum board false ceiling with 12.5 mm thick Gypsum boards, screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete. |
| 54 | Providing and Fixing Soft Fibre Acoustical Suspended Ceiling System with Optra (Bevelled Tegular) Edge Tiles of size 15mm Exposed Grid. The tiles should have Humidity Resistance (RH) of 95%, NRC 0.9 - 1.0, Light Reflectance ?85%, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 15mm , suitable for Green Building application, with Recycled content of 66% GW and 74% RW. The tile shall be laid on precoated G.I channel 32 with 15 mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm and 600 mm Cross Tees with a web height of 32 mm and a load carrying capacity of 7 Kgs/M2 with a minimum pull out strength of 100 kgs. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system The Tile and Grid system used together should carry a 10 year warranty. products approved as per GRIHA and BS 476 etc. complete. |
| 55 | Providing and applying paint of luster paint of approved quality with Low VOC level as measured by ASTMD 6886 specified by GS-11 standard such as Royal Aspira, Royal Atoms of Asian paints make or equivalent make as per colour and shead in two coat including preparing the surface with sand paper and coating the entire surface with mixture of whiting or glue and linseed oil and one coat of primer and the reafter painting in 2 coat to wall, inclusive of scaffolding etc. complete.(Item inclusive of painting of any decorative surface as per the total flat surface area and no extra factor for moulding or carvings to be paid separately.) |
| 56 | Mirror: Providing and fixing Mirrors of approved Indian quality, copper plated with 3/8\" thick plywood backing, in the masonary etc. |
| 57 | Providing and Fixing Door Shutter 60mm thk. with glass & Mortise lock finished using 18 milimeter thick Indian Standard Instution marked 710 marine plywood for shutter frame work covered with 12 milimeter thick Indian Standred Institution marked 710 marine plywood including 8 milimeter thick Painted glass fixed with 40 milimeter x 15 milimeter Teak Wood moulding. External side to be finished with 4 milimeter thick Venner with 6 milimeter horizontal groove with brass hinges, mortise lock, conciled door closer, fittings etc. complete. (without door frame) |
| 58 | AUDITORIUM CHAIRS: Providing & fixing of pushback with auto tip up auditorium chairs, synchro sliding mechanism, PCP (Polypropylene Copolymer) injection moulded / Thermoplastic housing for seat cushion & backrest. 80 mm wide arm rest in CP teakwood of specified size. Structure back & bottom frame of ERW tube made as per IS:3074-2005 and wing component in channel frame of HRCA sheet metal with wooden upholstery and sliding mechanism. (Chair handle to chair handle c/c shall be min 535mm).The seat shall be 510 mm deep x 450 mm wide at 450mm ‡ 10 mm from finished floor level and chair back of size 500mm wide x 720mm height with 1030 mm height from finish floor levelsuitable for steps of riser 138 mm height and tread of 1000 mm wide. Provision for including LED chair lights and respective numbers for the chairs and aisles as per chair layout. The back rest seat profile shall be confirming to ergonomically design profile ensuring lumber support.The fabric (samples should be approved by Engineer In-Charge), anchoring with fasteners, structural frame, PU foam, spring/ mechanism, wing etc.. Make: Godrej / Hof/Indosonic/Ambar |
| 59 | Providing & Laying 6mm thick Acoustic Nylon Carpet Flooring of make: Shaw/Kane/Milliken of approved shade and pattern laid above 10mm thick underlay and having solution dyed non woven synthetic fibre with proper backing having weight 26oz per sq.yard, Class I radiant panel, NBS smoke < 3.5KV, be fixed property after necessary leaving using proerietry adhesive for fixing of carpet as per manufacture specifications all as per desing shade apporved by Engineer-in-Charge. |
| 60 | Providing & fixing anti-slip Alluminium Step Nosing of Illumax or equivalent make, Aluminium Extrusion Rectangular/Square Frame.Visual standard dimensions should be 12\" x 6\" or as per steps dimensions in drawing.Power wattage:4.87 Wattage, water Resistance enclosures as per IP-20, No. of LEDs- Min. 72 Nos. of Epistar or equivalent make, Driver should be Mean Well or equivalent make. It should be tested for high voltage Tests 1500 V,50Hz,AC RMS applied for 1 Min between live parts and earthingh material. Also to be tested for Insulation Resistance test for 500V DC and resistance should be greater than 5mohms. black / grey / brown installed Alluminium Step Nosing by screwing to the ground surface and inserting the Rubber strip to cover the screw used for fixing etc. complete. |
| 61 | Providing and fixing double scaffolding system (cup lock type) for the internal side of building / structure, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40 mm dia M. S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M. S. Tubes, M. S. tube chall is, M. S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of ceiling works including the MEP works to be carried and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc.. complete as per directions and approval of Engineer-in-charge.Note:-(1) The Floor area of the scaffolding shall be measured for payment purpose considering 12 m Height. (2) Time frame of minimum 2 month of works to be considered and the same to be retained as per approval ot Engineer-in-charge. |
| 62 | Providing and Fixing Acoustical Polyethylene Terephthalate Standard Indosonic Tiles of size 595mm x 595mm, made up from compressed polyester Fibre of 10 mm thickness, 1600 GSM Density. The Tech-Panel should be Highly resistance to humidity (RH:99%), water vapour diffusion resistance (as per ISO-12572-2016 standards), zero mold growth (as per EN-15101-1 standards), Highly versatile and (Class A) flame retardant (as per BS-3119 standards, IS-15061 standards) and Thermal conductivity (as per EN12667 standards), The tiles should be fixed on pre-coated SS T-Grid of 15mm, having the grid work of 600x600mm with suspension, wall angles, runners and all other accessories. Tile colour should be as per approval from the Architect/Engineer in charge. The rate should be including of laying of 12mm RGB silver foiled sheet (Density 48 kg/m3) and high quality acoustic fleece should be placed above the false ceiling tiles. The Panel should have an Avg NRC of 0.80 |
| 63 | Acoustic Wooden Soundtrap Indosonic Slats Ceiling:Providing and Fixing of Soundtrap Wooden Perforated Indosonic Panels of size 595mm x 595mm, made up from High Density Moisture Resistant Board (HDHMR),Thermo treated (As per Manufacturers recommendations) of 12mm thickness, having perforation area of 3mm to10mm and slotted area of appropriate size, fixed with High Quality Acoustic Fleece. The Panel should be Highly resistance to humidity (RH:99%), water vapour diffusion resistance (as per ISO-12572-2016 standards), zero mold growth (as per EN-15101-1 standards), Highly versatile and (Class A) flame retardant (as per BS-3119 standards, IS-15061 standards) and Thermal conductivity (as per EN12667 standards). The Tiles should be fixed on SS /GI T-Grid of 25mm, having the grid work of 600x600mm with suspension, wall angles, runners and all other accessories, with 12mm thick RGB of 48 Kg/m3 Density and acoustic fleece. Tile colour should be as per approval from the Architect/Engineer in charge. The Panel should have an Avg NRC of 0.85 |
| 64 | Acoustic Soundtrap Wooden Perforated Indosonic wall Paneling for rear wall, side walls and stage front:Providing and fixing in position Acoustic Soundtrap Wooden Perforated/Slotted Indosonic wall Panels made up from High Density Moisture Resistant Board (HDMR) of 12mm thickness, having perforation area of 3mm to10mm and slotted area of appropriate size, fixed with High Quality Acoustic Fleece. The Panel should be Highly resistance to humidity (RH:99%), water vapour diffusion resistance (as per ISO-12572-2016 standards), zero mold growth (as per EN-15101-1 standards), Highly versatile and (Class A) flame retardant (as per BS-3119 standards, IS-15061 standards) and Thermal conductivity (as per EN12667 standards), which is fixed on Anodised Aluminium framework of 50x50mmx1.5mm equally spaced at distance welded at 600x600mm center to center, Anodised Aluminium hollow space section should be filled with Polyurethane sound resistance chemical. The wall should be treated with Mass Loaded Vinyl Membrane and Suitable wall isolators should be fixed to the frame to achieve the STC of 40dBA. The frame infill should be of 50mm Polysynth (density 1000 GSM). The framework should be finished with 10mm Marine-ply having 22 to 25mm Helmholtz perforations. The paneling shall be finished as per the design, sizes, colour, and joints as directed by the architect, including scaffolding, cut-outs, joints and all other elements complete in all respect. The product should have an acoustical performance of 0.80 NRC. Approved make: Indosonic/ Armstrong/Hunter Douglus |
| 65 | Providing and fixing in position Acoustical Polyethylene Terephthalate Indosonic Wall Panel of size 1200mmx 600 mm, made up from compressed polyester Fibre of 10 mm thickness, 1600 GSM Density. The Tech-Panel should be highly resistance to humidity (RH: 99%), water vapour diffusion resistance (as per ISO-12572-2016 standards), zero mold growth (as per EN-15101-1 standards), highly versatile and (Class A) flame retardant (as per BS-3119 standards, IS-15061 standards) and Thermal conductivity (as per EN12667 standards), the product should have an acoustical performance of 0.90 NRC. The Sheet Panel should be fixed on Anodised Aluminium framework of 50mmx50mmx1.5mm equally spaced and welded at distance of 600x600mm center to center, Anodised Aluminium hollow space section should be filled with Polyurethane sound resistance chemical. The wall should be treated with 2mm Mass Loaded Vinyl Membrane and Suitable Wall Isolators should be fixed to the frame to achieve the STC of 30dBA. The frame infill should be of 50mm Polysynth (density 1000 GSM). The framework should be finished with 10mm Marine-ply having 22 to 25mm Helmholtz perforations. The exposed surface of the ply should be treated with finishing material of 9mm Non-woven panel by using heavy duty proprietary resin/adhesive. The paneling shall be finished as per the design, sizes, colour, and joints as directed by the architect, including scaffolding, cut-outs, joints and all other elements complete in all respect. |
| 66 | Providing and fixing in position Acoustical Polyethylene Terephthalate Indosonic Wall Panel of size 2400mm x 1200mm, made up from compressed polyester Fibre of 10 mm thickness, 1600 GSM Density. The Tech-Panel should be highly resistance to humidity (RH: 99%), water vapour diffusion resistance (as per ISO-12572-2016 standards), zero mold growth (as per EN-15101-1 standards), highly versatile and (Class A) flame retardant (as per BS-3119 standards, IS-15061 standards) and Thermal conductivity (as per EN12667 standards), the product should have an acoustical performance of 0.80 NRC. The Sheet Panel should be fixed on Anodised Aluminium framework of 50mmx50mmx1.5mm equally spaced and welded at distance of 600x600mm center to center, Anodised Aluminium hollow space section should be filled with Polyurethane sound resistance chemical. The wall should be treated with 2mm Mass Loaded Vinyl Membrane and Suitable Wall Isolators should be fixed to the frame to achieve the STC of 30dBA. The frame infill should be of 50mm Polysynth (density 1000 GSM). The framework should be finished with 10mm Marine-ply having 22 to 25mm Helmholtz perforations. The exposed surface of the ply should be treated with finishing material of 9mm Non-woven panel by using heavy duty proprietary resin/adhesive. The paneling shall be finished as per the design, sizes, colour, and joints as directed by the architect, including scaffolding, cut-outs, joints and all other elements complete in all respect.netting. Approved make : Indosonic /Armstrong/Hunter Douglus |
| 67 | Providing and fixing 100×15mm thick Acoustic wooden perforated Indosonic Slats skirting of matching shade of wall paneling slats, at the bottom of wall paneling. The skirting shall be fixed over 12mm thick commercial ply to match the level of paneling. |
| 68 | Designing, fabricating, testing, installing and fixing in position 60 mm thick acoustic fire door with seasoned Hardwood frame (size 100x75mm with rebate of required size (door should have a 6mm thick glass vision panel). Shutter to be made using frame of 34x100mm section of chemically treated seasoned wood. All wood work shall be treated as termite free. 12 mm thick commercial plywood of Approved make with 01 mm thick lamination with suitable adhesive of approved make and shade shall be fixed over and cavity shall be filled with acoustic and fire insulation material of 3mm thick MLV Sheet of min. 1700 Kg/m3 density and rockwool fire insulation material of 60 Kg/m3 density. Periphery of shutter to be covered with 12mm thick teak wood lipping matching to shade of door shutter. Weather seal to be fixed on frame of door to fill the gap of shutter and wooden frame (chowkhat). Dropdown seal to be fixed in shutter to block gap with floor when door is closed. The cost shall Includes all Hardware fittings like Heavy duty SS hinges of suitable size, Handles, Tower bolts, door closers, locking arrangement and panic bar of Approved brand and manufacture.Approved make : Global Fire/ Navair/ Absound Overseas/Saint gobain |
| 69 | BlProviding & laying at site finished Bamboo flooring of approved make, color, shade & finish of minimum 12 mm thickness and of minimum size 960mm x 96 mm. The material shall fulfill the following standards : Flammability as per ASTM-E648 with Class-1 rating as per NFPA, Smoke density as per ASTM-E622 shall be less than 450 for flaming or non flaming mode, compressive strength as per ASTM-D3501-86A shall not be less than 52 MPa parallel to grain, 17 MPa perpendicular to grain & 116 MPa flat at 50% strain. Tensile strength as per ASTM-D3500- 90 shall not be less than 105 MPa parallel to grain, Slip resistance coefficient of friction as per ASTM D2047 shall be 0.71, Abrasion resistance weight loss as per ASTM-C501 shall not be more than 350 gms (H-22 calibrated wheels loaded with 1000 gms weight at 70 RPM for 1000 cycles) and Moisture content as per ASTM-D4442 oven dry method shall not be more than 7.8%. (Skirting profiles, trims etc shall be included & not paid extra) Approved make : EGO ,Bambusa |
| 70 | Providing & Laying 6mm thick Acoustic Nylon Carpet Flooring of make: Shaw/Kane/Milliken of approved shade and pattern laid above 5mm thick underlay and having solution dyed non woven synthetic fibre with proper backing having weight 15oz per sq.yard, Class I radiant panel, NBS smoke < 3.5KV, be fixed property after necessary leaving using proerietry adhesive for fixing of carpet as per manufacture specifications all as per desing shade apporved by Engineer-in-Charge. |
| 71 | Supply and fix 4.3mm thick x 30m x 2.00m wide Flotex sheeting, butting the factory edges for seaming. Spread FloorworX No. 60 Plus acrylic adhesive on the exposed substrate with a trowel having triangular notches 1.78mm x 1.78mm x 1.6mm at 3.0mm centres at the rate of between 5.5 to 6.5m² per litre depending on sub-floor porosity, on a previously prepared sub-floor by the builder, as described above and elsewhere.(Skirting profiles, trims etc shall be included & not paid extra) Brand Flotex |
| 72 | Providing and fixing in place ,,3 layered ,horizontal motorised curtain system , accoustics approved.Main fabric - vevet with satin , middle facbric satin , back fabric - satin .Cost to be quoted with required steel frameworks and necessary supporting system ,which will be executed post discussions and clarifications to the site endineers . Load details and structural drawings to be submitted pre execution stage .Motors required to be as per the required wattage and proposed by the OEM .Operational manuals ,training and warranty to be considered Main location width to be considered 20m x height 4 m |
| 73 | Providing Pest control and Anti-termite treatment by appointing a specialised agency as per the specifications mentioned by the Bureau of Indian Standards and Agencies specifications (whichever is higher), for General Civil, Plumbing,/ Drainage and timber/ Carpentry works, Gypsum related work, including a 10-year guarantee under suitable undertaking on stamp paper etc., complete as directed. (Mode of measurement to be on carpet-area of floor and not the area of surface treated.). Products to be used shall be eco friendly, non hazardous chemicals, technical supporting documents shall be provided for the same, for approval. |
| 74 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 3.00 m.) By Manual Means |
| 75 | Providing and laying Cast in situ/Ready Mixcement concrete in M20 of trap/ granite/quartzite/gneiss metal for steps including steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 76 | Providing and laying Cast in situ/ Ready Mix cement concrete M-25 of trap / granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering, formwork ,cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 77 | Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 78 | Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 79 | Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. |
| 80 | Providing and applying Anti corrosive treatment to reinforcement as per cement polymer composite coating (C.P.C.C.) method developed by C.E.C.R.I. including cleaning the bar by means of any established mechanical or manual method for removing rust and deleterious material, applying rapid setting primer and cement polymer sealing coat of approved and licensed by CECRI including redoing the process if damage occurs during handling, stacking etc. complete. (With prior approval of SE) |
| 81 | Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. |
| 82 | Providing and laying Lapato or river finish granite stone of 18 to 20 mm thick for cladding On C.M. 1:6 including filling joints with polymer base filler nosing / moulding the sharp edges wherever necessary, curing, etc. complete. |
| 83 | Providing and laying in position flooring of Lapato / River finish granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. |
| 84 | Providing and fixing machine cut machine polished 18 mm to 20 mm thick Lapato / River finish granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete. |
| 85 | Providing,aupplying,fabricating and fixing panel of aluminium composite panel cladding in approved shape made out of 4 mm thick ACP sheet material consisting of 3mm thick FR grade mineral core following NBC part IV Fire and life safety (having 2 hours fire resistance in accordance to ASTM E119-12 and BS476 part 6 and 7 class O) sandwitched between two aluminium sheets (each 0.5 mm thick of AA 5005/AA3105 grade) The aluminium composite panel cladding sheet shall be coil coated with kynar 500 based PVDF/Lumiflon based fluropolymer resin (having 70:30 ratio of PVDF and acrylic) coating of approved colour and sg=hade on top face and polymer (service) coating of bottom face as specified using stainless steel screws,nuts,bolts,washers,cleats,weather silicon sealent,backer rods etc .overall weight of the ACP shall not be less than 7.5 kg/sqm) |
| 86 | Providing and fixing mild steel grill railing weighing 20 kg / sqm. with PVC handrail cover and newel post for staircases, including fabricating, fixtures, drilling holes in concrete / other surface, erecting the grill work, necessary welding, fixing by nuts and bolts, fixing PVC handrail cover, with one coat of anticorrosive paint and two coats of oil painting with approved colour and shade, remaking the damaged surface, cleaning, etc. complete. |
| 87 | Providing and fixing HPL for exterior façade work using aluminum rectangular channel for screw fixing with channel and wall approx. 450 to 600mm between two channels as well as between two fasteners and applying VHB tape with PU sealant for fixing of panel on it in proper alignment, pattern, size shape required as per design etc. complete. |
| 88 | Glass Partition :Providing & fixing 12 mm thk. Glass Partition with Profie finshed using 12 mm thk. Toughen glass, diamond edge polish on all sides and as per design N.R. frosting processed with aluminu profile fittings and necessary hardware for fixing as per design. complete. |
| 89 | Glass Door: Providing & fixing 12 mm thk. Glass Door with Patch &Profie finshed using 12 mm thk. Toughen glass, diamond edge polish on all sides and as per design N.R. frosting processed with aluminu profile fittings and necessary hardware for fixing as per design. complete. |
| 90 | Providing and fixing heavy duty inter locking concrete Rubber mould glossy paving blocks of 80 mm thickness of having a strength of 400 kg/Sq.cm. of approved quality and shape on a bed of crushed sand of 25 to 30 mm thick including skirting joints and cleaning etc. complete. (using 100% crushed sand) |
| 91 | Providing and casting in situ or precast tapering R.C.C. M-20 Barrier type Kerb with gutter ( as per IRC 86 1983) embedded 125mm below ground level over M-10 PCC finished neatly with C.M. 1:2, setting the same in C.M. 1:2, including the required excavation in any strata and removing the excavated stuff any where in city and redoing the surface as specified and directed by Engineering In-charge. Using Concrete Batching and Mixing Plant |
| 92 | Providing and fixing Aluminium structural Glazing usining 5mm bronze one way reflective of ( AIS ) make aproved colour and shade with 63 x 38 mm x 1.5 mm Aluminium extruded section , weight about 2.5 to 2.8 kg per 12 feet,which will be powder coated / color anodized secure to the masonry finish with mild steel or aluminum brackets powder quoted with anchor fasteners in chrome finish necessary hardware accessories in ss plated provide with the help of 6 x 6 mm spacer tape of Norton or Laim Make , silicon sealants structural glazing grade of 995/795 and 789 Dow corning as per detailed drawing etc.complete. |
| 93 | Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge. Note:- (1) The elevational area of the scaffolding shall be measured for payment purpose. (2) The payment will be made once only for execution of all items for such works. |
| 94 | Providing and fixing construction three layer monofilament safety net including first layer of machine knotted 5mm braided Rope with 100 mm x 100 mm mesh size, second layer of machine knotted 2.5 mm braided rope with 25 mm x 25mm mesh size, third layer of monofilament stabilizer and net with welding / grinding splatter resistance, border rope of 12 mm maximum including the cord of 12 mm maximum at tower corners at 1.50 meter long at every 1.50 meter distance including require size and as per specification and certification approved including testing criteria for safety net EN1263-1 including drop test (dynamic test) and energy absorption test (En-1263-1:2002) and as per instructions and approved of the Engineer - In - Charge (Horizontal Safety Net) |
| 95 | Providing and fixing Jute Kantan (Tarat) screen to the scaffold-ing for external guniting as directed including removing the same after the work is over etc. complete. |
| 96 | Providing and fixing mild steel grill gate with angle iron frame 65mm x 65mm x 10mm with iron bars at 150mm C/C and diagonal flats as per the detailed drawing including hinges, pivot block locking arrangement, welding riveting and oil painting of three coats of approved shade Weight of gate 35 Kg/Smt. |
| 97 | Providing & Filling Red Hill Earth & Cow Dung Manure and soil excaveted from pit in the excavated pits mixing in 2:1:1 proportion, watering, weeding after every watering before planting the shrub, leveling, including transport and unloading as per specified etc. Complete. |
| 98 | Providing and fixing GRC Dummy Round Window of Size 1350mm dia. X 150mm Depth including fixing of Acryllic glass as per design etc. complete. |
| 99 | Providing and fixing GRC Stepped Band 150mm width x 150mm depth or as shown in the drawing or indicated by the architect as mentioned etc. complete. |
| 100 | Providing and fixing GRC Arch unit above Window 1800mm wide including Medallion/flower inside and GRC lintel including fixing of same as shown in the drawing or indicated by the Architect as mentioned below with all lead and lift etc.complete. |
| 101 | Providing and fixing GRC Arch unit above Window 2100mm wide including Medallion/flower inside and GRC lintel including fixing of same as shown in the drawing or indicated by the Architect as mentioned below with all lead and lift etc.complete. |
| 102 | Providing and fixing GRC Plain Lintel 150mm x 50mm deep or as shown in the drawing or indicated by the Architect as mentioned below with all lead and lift etc.complete. |
| 103 | Providing and fixing 1500 x 1050 GRC half Balustrades with 150mm thick top and bottom as per image or as shown in the drawing or indicated by the Architect as mentioned below with all lead and lift etc.complete. |
| 104 | Providing and fixing 1800 x 1050 GRC half Balustrades with 150mm thick top and bottom as per image or as shown in the drawing or indicated by the Architect as mentioned below with all lead and lift etc.complete. |
| 105 | Providing fixing GRC Cornice Band Type-1 of size 800 W x 225 D as per image or as shown in the drawing or indicated by the Architect as mentioned below with all lead and lift etc.complete. |
| 106 | Providing fixing GRC Cornice Band Type-2 of size 350 W x 150 D as per image or as shown in the drawing or indicated by the Architect as mentioned below with all lead and lift etc.complete. |
| 107 | Providing fixing GRC Cornice Band Type-3 of size 300 W x 250 D projected as per image or as shown in the drawing or indicated by the Architect as mentioned below with all lead and lift etc.complete. |
| 108 | Providing and fixing GRC Cornice Brackets as per Image or as shown in the drawing or indicated by the Architect as mentioned below with all lead and lift etc.complete. |
| 109 | Providing and fixing GRC Small Dummy Circular windows of size 750 Dia 75 W x 150 D as per image or as shown in the drawaing or indicated by the Architect as mentioned below with all lead and lift etc.complete. |
| 110 | Providing and fixing GRC Grooved Panel 35mm thick having grooves 20mm deep and 40mm height as per image or as shown in the image or indicated by the Architect as mentioned below with all lead and lift etc.complete. |
| 111 | Providing and fixing Plain GRC as per image or as per shown in the drawing or indicated by the Architect as mentioned below with all lead and lift etc.complete. |
| 112 | Providing and fixing 600mm Dia Circular columns over existing RCC Columns of 450mm dia as per image or as per shown in the drawing or indicated by the Architect as mentioned below with all lead and lift etc.complete. |
| 113 | Providing and fixing Base - 2 Rings and capitals - 2 rings for above columns or as shown in the drawing or indicated by the Architect as mentioned below with all lead and lift etc.complete. |
| 114 | Providing and fixing GFRC column for compound wall or as shown in the drawing or indicated by the Architect as mentioned below with all lead and lift etc.complete. |
| 115 | Providing and fixing Screen Panel as per drawing for compound wall or or as shown in the drawing or indicated by the Architect as mentioned below with all lead and lift etc.complete. |
| 116 | Providing and fixing alluminium frame (for fixing of GRC Dummy Round Window) on walls at all heights using alluminium square/ rectangular tube in the required pattern as per architectural drawing, including cost of cutting, bending, screwing etc. The frame work shall be fixed to the wall with the help of brackets / lugs of angle alluminum / flats etc. which shall be screwed to the frame and with approved expansion hold fasteners on CC/RCC surface, including drilling necessary holes. etc. complete. |
| 117 | Providing and fixing alluminium frame (for fixing of GRC Stepped Band ) on walls at all heights using alluminium square/ rectangular tube in the required pattern as per architectural drawing, including cost of cutting, bending, screwing etc. The frame work shall be fixed to the wall with the help of brackets / lugs of angle alluminum / flats etc. which shall be screwed to the frame and with approved expansion hold fasteners on CC/RCC surface, including drilling necessary holes. etc. complete. |
| 118 | Providing and fixing alluminium frame (for fixing of GRC Arch unit above Window of 1800mm wide) on walls at all heights using alluminium square/ rectangular tube in the required pattern as per architectural drawing, including cost of cutting, bending, screwing etc. The frame work shall be fixed to the wall with the help of brackets / lugs of angle alluminum / flats etc. which shall be screwed to the frame and with approved expansion hold fasteners on CC/RCC surface, including drilling necessary holes. etc. complete. |
| 119 | Providing and fixing alluminium frame (for fixing of GRC Arch unit above Window 2100mm wide) on walls at all heights using alluminium square/ rectangular tube in the required pattern as per architectural drawing, including cost of cutting, bending, screwing etc. The frame work shall be fixed to the wall with the help of brackets / lugs of angle alluminum / flats etc. which shall be screwed to the frame and with approved expansion hold fasteners on CC/RCC surface, including drilling necessary holes. etc. complete. |
| 120 | Providing and fixing alluminium frame (for fixing of GRC Plain Lintel 150mm x 50mm deep) on walls at all heights using alluminium square/ rectangular tube in the required pattern as per architectural drawing, including cost of cutting, bending, screwing etc. The frame work shall be fixed to the wall with the help of brackets / lugs of angle alluminum / flats etc. which shall be screwed to the frame and with approved expansion hold fasteners on CC/RCC surface, including drilling necessary holes. etc. complete. |
| 121 | Providing and fixing alluminium frame (for fixing of 1500 x 1050 GRC half Balustrades) on walls at all heights using alluminium square/ rectangular tube in the required pattern as per architectural drawing, including cost of cutting, bending, screwing etc. The frame work shall be fixed to the wall with the help of brackets / lugs of angle alluminum / flats etc. which shall be screwed to the frame and with approved expansion hold fasteners on CC/RCC surface, including drilling necessary holes. etc. complete. |
| 122 | Providing and fixing alluminium frame (for fixing of 1800 x 1050 GRC half Balustrades ) on walls at all heights using alluminium square/ rectangular tube in the required pattern as per architectural drawing, including cost of cutting, bending, screwing etc. The frame work shall be fixed to the wall with the help of brackets / lugs of angle alluminum / flats etc. which shall be screwed to the frame and with approved expansion hold fasteners on CC/RCC surface, including drilling necessary holes. etc. complete. |
| 123 | BlankProviding and fixing alluminium frame (for fixing of GRC Cornice Band Type-1 of size 800 W x 225 D) on walls at all heights using alluminium square/ rectangular tube in the required pattern as per architectural drawing, including cost of cutting, bending, screwing etc. The frame work shall be fixed to the wall with the help of brackets / lugs of angle alluminum / flats etc. which shall be screwed to the frame and with approved expansion hold fasteners on CC/RCC surface, including drilling necessary holes. etc. complete. |
| 124 | Providing and fixing alluminium frame (for fixing of GRC Cornice Band Type-2 of size 350 W x 150 D ) on walls at all heights using alluminium square/ rectangular tube in the required pattern as per architectural drawing, including cost of cutting, bending, screwing etc. The frame work shall be fixed to the wall with the help of brackets / lugs of angle alluminum / flats etc. which shall be screwed to the frame and with approved expansion hold fasteners on CC/RCC surface, including drilling necessary holes. etc. complete. |
| 125 | Providing and fixing alluminium frame (for fixing of GRC Cornice Band Type-3 of size 300 W x 250 D) on walls at all heights using alluminium square/ rectangular tube in the required pattern as per architectural drawing, including cost of cutting, bending, screwing etc. The frame work shall be fixed to the wall with the help of brackets / lugs of angle alluminum / flats etc. which shall be screwed to the frame and with approved expansion hold fasteners on CC/RCC surface, including drilling necessary holes. etc. complete. |
| 126 | BlankProviding and fixing alluminium frame (for fixing of GRC Cornice Brackets) on walls at all heights using alluminium square/ rectangular tube in the required pattern as per architectural drawing, including cost of cutting, bending, screwing etc. The frame work shall be fixed to the wall with the help of brackets / lugs of angle alluminum / flats etc. which shall be screwed to the frame and with approved expansion hold fasteners on CC/RCC surface, including drilling necessary holes. etc. complete. |
| 127 | BlankProviding and fixing alluminium frame (for fixing of GRC Small Dummy Circular windows) on walls at all heights using alluminium square/ rectangular tube in the required pattern as per architectural drawing, including cost of cutting, bending, screwing etc. The frame work shall be fixed to the wall with the help of brackets / lugs of angle alluminum / flats etc. which shall be screwed to the frame and with approved expansion hold fasteners on CC/RCC surface, including drilling necessary holes. etc. complete. |
| 128 | Providing and fixing alluminium frame (for fixing of GRC Grooved Panel 35mm thick) on walls at all heights using alluminium square/ rectangular tube in the required pattern as per architectural drawing, including cost of cutting, bending, screwing etc. The frame work shall be fixed to the wall with the help of brackets / lugs of angle alluminum / flats etc. which shall be screwed to the frame and with approved expansion hold fasteners on CC/RCC surface, including drilling necessary holes. etc. complete. |
| 129 | Providing and fixing alluminium frame (for fixing of Plain GRC) on walls at all heights using alluminium square/ rectangular tube in the required pattern as per architectural drawing, including cost of cutting, bending, screwing etc. The frame work shall be fixed to the wall with the help of brackets / lugs of angle alluminum / flats etc. which shall be screwed to the frame and with approved expansion hold fasteners on CC/RCC surface, including drilling necessary holes. etc. complete. |
| 130 | Providing and fixing alluminium frame (for fixing of 600mm Dia Circular columns) on walls at all heights using alluminium square/ rectangular tube in the required pattern as per architectural drawing, including cost of cutting, bending, screwing etc. The frame work shall be fixed to the wall with the help of brackets / lugs of angle alluminum / flats etc. which shall be screwed to the frame and with approved expansion hold fasteners on CC/RCC surface, including drilling necessary holes. etc. complete. |
| 131 | Providing and fixing alluminium frame (for fixing of Base - 2 Rings and capitals - 2 rings for above columns) on walls at all heights using alluminium square/ rectangular tube in the required pattern as per architectural drawing, including cost of cutting, bending, screwing etc. The frame work shall be fixed to the wall with the help of brackets / lugs of angle alluminum / flats etc. which shall be screwed to the frame and with approved expansion hold fasteners on CC/RCC surface, including drilling necessary holes. etc. complete. |
| 132 | Providing and fixing alluminium frame (for fixing of GFRC column) on walls at all heights using alluminium square/ rectangular tube in the required pattern as per architectural drawing, including cost of cutting, bending, screwing etc. The frame work shall be fixed to the wall with the help of brackets / lugs of angle alluminum / flats etc. which shall be screwed to the frame and with approved expansion hold fasteners on CC/RCC surface, including drilling necessary holes. etc. complete. |
| 133 | Providing and fixing alluminium frame (for fixing of Screen Panel) on walls at all heights using alluminium square/ rectangular tube in the required pattern as per architectural drawing, including cost of cutting, bending, screwing etc. The frame work shall be fixed to the wall with the help of brackets / lugs of angle alluminum / flats etc. which shall be screwed to the frame and with approved expansion hold fasteners on CC/RCC surface, including drilling necessary holes. etc. complete. |
| 134 | Removing any kind of debris including loading in truck and conveying to dumping point approved by MCGM, unloading, spreading etc. complete. With all leads and lifts. |
| 135 | Sub Work I : Supply,Installation,Testing & Commissioning of 150W High Quality LED Parcan Light complete with, Lamp source 3200K CCT Colour temperature, CRI & TLCI Values above 95, DmX 512 dimming with 3 channel control, Beam Angle of 9° / 25° / 45°, Total Power Consumption of 165W, High quality output replacing 1000W Halogen Par, Flicker Free 100% for Tv & Film Cameras, 11.7KHz Refresh Rate, Linear Dimming 0 ~ 100%, Fuse and Internal safety protections , Strobe option Adjustable 1~25 times/Sec Variable, Fixture provided with Yoke of Manual Adjustment, 5 Pin XLR or 3 Pin XLR for DmX Black powder coated body, |
| 136 | Supply, Installation, Testing & Commissioning of LED Moving Head ProfileHigh bright long throw 350W Chip On Board Daylight White LED 1 Static Gobo Wheel – 10 Fixed Metal Gobos 21/26 Channel DmX Control, Moto Dual Prism Mode 3 Colour Wheels – 9 Colours + CMY Motorized Zoom from 7° ~ 31° Motorized Focus and Frost, High Bright Daylight 6500K Open 7 Interchangeable Glass Gobos + Open Master Slave, Test Modes, 8 Bit/ 16 Bit High Precision Movement Sound Active and Auto Run Mode, Pan Angle 540°,Tilt Angle 270°. DmX control through 3 / 5 Pin XLR’s, IP20 rated product. |
| 137 | Supply,Installation,Testing & Commissioning of of 200W LED Blinder Light 30 Degree complete with 3200K CCT 2x100W Chip On Board LED Lamp source, DmX 512 dimming with 4 /8 Channel modes, CRI & TLCI Value > 90, Strobe option Adjustable 1 ~ 25 times / Sec Variable, Beam Angle 30 Degree, Total Power Consumption of 220W, 11.7KHz Refresh Rate, In built preset’s for effects, Fuse and Internal safety protections, Active Cooling with Low Noise Fan, 5 Pin XLR or 3 Pin XLR for DmX, High quality well designed inbuilt reflector, Flicker Free 100% for Tv & Film Cameras, Black finish housing, IP20 protection, Having Strobe option and smooth dimming, illuminate Stage with uniform light intensity levels. |
| 138 | Supply,Installation,Testing & Commissioning of of 54 x 3W LED Par Light RGBW, Beam Angle 25° complete with RGBW 3W Lamp source x 54 Pcs, DmX 512 dimming with 8 Channel , High Bright Red, Green, Blue, White LED’s Source, Unlimited Color Mixing through DmX 0 ~ 100% Linear dimming, In built presets for different colors, Strobe Mode 20 times/Sec, Data DmX through 3 / 5 Pin XLR’s, 65dB ~ 130dB Sound sensing capacity, Power In and Out Connections, High precision colors, IP20 protection Powder coated Black finish housing, Having Sound Control & Master Slave Auto Run Mode, Illuminate the Indoor stage with unlimited colour effects, Rigidly built pressure die-casted Aluminium body. |
| 139 | Supply,Installation,Testing & Commissioning of of 54x3W LED 3200K Par Light Beam Angle 25° complete with 3200K 3W Lamp source x 54 Pcs, Having CRI TLCI Values above 95, Flicker Free for high FPS, Smooth fade in and Fade out, High precision steady color, No heat, DmX 512 dimming with 2 Channel, 0 ~ 100%, Powder coated Black finish housing, Rigidly built pressure die-casted Aluminium body, LED Easy view display, Data DmX through 3 / 5 Pin XLR’s, 65dB ~ 130dB Sound sensing capacity, Power In and Out Connections, Total Power Consumption of 180W, Sound Active Mode Control, IP20 protection. |
| 140 | Supply,Installation,Testing & Commissioning of of Light fixture mouting clamp, Customized for suspending on fixed bars on stage, Made up of Aluminium Die casted, MS threaded T bolt with yellow passivation finish, Complete with black powder coating matt black finish. Safe working load 150 KG, Suitable to Batten of size 30 OD to 60 OD, ) |
| 141 | Supply,Installation,Testing & Commissioning of of Light Fixture dual safety, Chain made up of GI wire rope, Bundled and twisted together Having load bearing capacity above 200 Kgs, Sleve on the rope. Carabiner Clip |
| 142 | Supply,Installation,Testing & Commissioning of Suspender cum clamps designed made out of MS material, 150mm x 150mm x 5mm MS Base plate, Threaded rod, Black powder coated finish, Suitable to hold various type grid & other rigging systems. |
| 143 | SITC of Power Distribution Electrical panel having a Incomer of 100A, floor mount / rack mount / wall mount Nuetral separation Made using incomer of L&T or Schneider make, Voltmeter, Ammeter display for reading visualization Individual MCB control for 26 outgoing circuits RYB Phase indicators internally wired using IS certified wires and cables Provided with ivery connectors for the internal terminations and external outgoing connecting points Custom built as per specification and project requirement. |
| 144 | Supply,Installation,Testing & Commissioning of High quality power junction box 4 way made up of MS Sheet metal fabricated housing black powder coated, fibre glands of suitable size fitted with Powercon or IEC connector Box 10A. |
| 145 | Supply,Installation,Testing & Commissioning of High quality Dimming In junction box 1 way made up of MS Sheet metal fabricated housing black powder coated, fibre glands of suitable size fitted with 5 Pin DmX XLR Female socket |
| 146 | Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no EA-EP. |
| 147 | Providing & erecting Hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner. |
| 148 | Supply, Installation, Testing & Commissioning ofSITC of Cable Connecting Circuit Boxes for the termination of cables from Electrical panel to the grid level point made out of MS Sheet metal fabricated housing duly powder coated with matt black texture finish paint, fitted with required channels and ivery connectors, necessary glands etc. |
| 149 | Supply,Installation,Testing & Commissioning of DmX Male Female Connectors 5 Pin having rubber sheeth protection for Cross connecting DmX wiring connections |
| 150 | Supply,Installation,Testing & Commissioning of DmX Male Termination Connector 5 Pin soldered with required capacity of resistor for signal deframing |
| 151 | Supply,Installation,Testing & Commissioning of DmX Controller consits of 24 Physical Faders to control atleast 96 channels, 4 Individual page control switches, Master control fader, Black out mode, Scene saving option upto 96 memories, LCD display, Smooth movement faders , Easy access key pads, DmX 512 protocol, 5 Pin XLR Output, Optional chase & multifunction keys, Sequence mode select |
| 152 | Supply Installation, Testing & Commmissioning of Opto isolated RDM enabled DmX splitter unit provided with, 8 Isolated outputs Slow blow safety fuse 5 Pin XLR for output interface Dual mode to select 2 universe operation DmX Input through 5 Pin XLR Connector Powder coated compartment finish Mounting brackets for grid mount. |
| 153 | Supplying & erecting mains with 3x2.5 sq.mm FRLHS copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 154 | Supply,Installation,Testing & Commissioning of 5 Core DmX Cable with Sheathed housing on the cable, well designed insulation, low noise suitable to transmet DmX signal. |
| 155 | Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete. |
| 156 | Supply,Installation,Testing & Commissioning of DmX Controller consits of 24 Physical Faders to control atleast 512 channels, 4 Individual page control switches, Master control fader, Black out mode, Scene saving option upto 96 memories, LCD display, Smooth movement faders , Easy access key pads, DmX 512 protocol, 5 Pin XLR Output, Optional chase & multifunction keys, Sequence mode select |
| 157 | Supply,Installation,Testing & Commissioning of Motor Control Panel cum remote control 4 Way providing power input for motors internally neatly wired with contactors having individual motor control with required Push button, Emergency trip, RYB indicators, Supply Indictor and necessary meters. Motor control panel duly powder coated with ash grey paint texture finish with all required safety features |
| 158 | Sub Work II : Supply,Installation,Testing & Commissioning of Suspender cum clamps designed made out of MS material 150mm x 150mm x 5mm MS Base plateThreaded rod, Black powder coated finish Suitable to hold various type grid & other rigging systems. |
| 159 | Supply,Installation,Testing & Commissioning of C Profile MS Hot rolled strips 3mm thick with Extra U bend used either to create basic supports Customized 40 x 50mmm, Makes easier to suspend all the stage machinery Duly powder coated Matt black texture finish paint |
| 160 | Supply,Installation,Testing & Commissioning of Motor Control Panel cum remote control 4 Way providing power input for motors internally neatly wired with contactors having individual motor control with required Push button, Emergency trip, RYB indicators, Supply Indictor and necessary meters. Motor control panel duly powder coated with ash grey paint texture finish with all required safety features |
| 161 | Supply,Installation,Testing & Commissioning of Cable Connecting Circuit Boxes for the termination of cables from Electrical panel to the grid level point made out of MS Sheet metal fabricated housing duly powder coated with matt black texture finish paint, fitted with required channels and ivery connectors, necessary glands etc. |
| 162 | Supply,Installation,Testing & Commissioning of On Stage Fixed Valance Bar 16 Mtrs Length Straight as per the design made out of 40NB 48 OD Mild steel pipe dual barrel, supported to hang the Main Valance of the stage system duly powder coated with matt black texture finish paint. |
| 163 | Supply,Installation,Testing & Commissioning of High quality Velvet fabric fire retardant treated as per approved colour and make with a gathering of 100% stitched as per site condition, curtain provided with eyelets at every 200/250mm for uniform fixing on to curtain trollies (For Main Valance) Size: 16Mtr x 1.2Mtr. |
| 164 | Supply,Installation,Testing & Commissioning of Motorized Main Curtain minimum up to 22 mtr s straight, Centre partting as per design Made up of I Track for complete length Overlap of 0.5~0.9 Mtrs, Trollies uniformly distributed along the track at every 200/250mm with a master trolley. Open and close limit controller, Motor Cable termination box, Drive unit with suitable capacity of motor unit, GI Wire rope, Black texture finish paint, All metal parts are powder coated |
| 165 | Supply,Installation,Testing & Commissioning of High quality Velvet fabric fire retardant treated as per approved colour and make with a gathering of 100% stitched as per site condition, curtain provided with eyelets at every 200/250mm for uniform fixing on to curtain trollies (For Main Curtain) minimum Size:22 mtr x 6mtr |
| 166 | Supply,Installation,Testing & Commissioning of Fixed Rear Curtain 15 Mtrs straight, Centre partting as per design, Made up of I Track for complete length, Overlap of 0.5~0.9 Mtrs, Trollies uniformly distributed along the track at every 200/250mm with a master trolley, Suspension through Suspenders as per site conditions, 2 Wheeler trolly for curtain moment, All metal parts are powder coated, Black texture finish paint. |
| 167 | Supply,Installation,Testing & Commissioning of Glazzed Cotton fabric fire retardant treated as per approved colour and make with a gathering of 50% stitched as per site condition, curtain provided with eyelets at every 200/250mm for uniform fixing on to curtain trollies (For Rear Curtain) Size: minimum Size:22 mtr x 6mtr |
| 168 | Supply,Installation,Testing & Commissioning of On Stage Fixed Frill Bar minimum up to 12 Mtrs Length Straight as per the design made out of 40NB 48 OD Mild steel pipe dual barrel, supported to hang the frill, connected with MS Flat duly powder coated with matt black texture finish paint. |
| 169 | Supply,Installation,Testing & Commissioning of Glazzed Cotton fabric fire retardant treated as per approved colour and make with a gathering of 50% stitched as per site condition, curtain provided with eyelets at every 200/250mm for uniform fixing on to curtain trollies. (For Frills) Size: minimum up to 14 mtr x 1.2 mtr |
| 170 | Supply,Installation,Testing & Commissioning of Fixed Wing Structure designed as per site condition for a height approx minimum up to 6 Mtr x 2Mtr made up of MS Square tube of 25mm or higher size rested on pivotable trolley on a track for the rotation of the wing. |
| 171 | Supply,Installation,Testing & Commissioning of Glazzed Cotton fabric fire retardant treated as per approved colour and make with a gathering of 0% stitched as per site condition, curtain provided with eyelets at every 200/250mm for uniform fixing. (For Wing) minimum up to size 6 mtr x 2 mtr |
| 172 | Supply,Installation,Testing & Commissioning of FRLS Copper unarmoured Flexible cable having 7 Core each of 1.5 Sq mm size. |
| 173 | Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens , min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty. |
| 174 | Supply Installation, testing and commissioning of 9W Recessed LED Down light fixture (Dimmable) equivalent to Phillips make DN590B M LED10S-6500 PSD - 08W - 1000 Lumen |
| 175 | Supply Installation, testing and commissioning of Wall mounted decorative light fixture equivalent to Philips 37641 - Wall/Single spot |
| 176 | Supplying and erecting LED square / circular Max. 25 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2750 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 177 | LED Flexible Strip Lights with required Flexible Housing and Driver 7 W / Meter with ballast and complete Accessories.Similar to Model No. BGC401 550 |
| 178 | Supplying & erecting mains with 2x1.5 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG- MA/BW |
| 179 | Supplying & erecting mains with 2x2.5 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 180 | Supplying & erecting mains with 1x1.5 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG- MA/BW (Note 2) |
| 181 | Supplying & erecting mains with 1x2.5 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 182 | Supplying & erecting mains with 2x4 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 183 | Supplying & erecting HMS P.V.C. conduit 25 mm. dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 184 | Supplying & laying HMS PVC conduit 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 185 | Supplying & laying HMS PVC conduit 20 mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 186 | Supplying & erecting H.M.S. P.V.C. conduit 20 mm. dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 187 | Point wiring in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FR grade copper wire, flush type switch, earthing and required accessories as per specification No: WG-PW/SW |
| 188 | Supplying & erecting HMS P.V.C. conduit 32 mm. dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 189 | Supplying and erecting UPVC reinforced flexible conduit 20 mm in dia. conforming to I.S. with required number of couplings, PVC bushes, check nuts etc. complete. |
| 190 | Supplying and erecting UPVC reinforced flexible conduit 25 mm in dia. conforming to I.S. with required number of couplings, PVC bushes, check nuts etc. complete. |
| 191 | Supplying and erecting UPVC reinforced flexible conduit 31/32 mm in dia. conforming to I.S. with required number of couplings, PVC bushes, check nuts etc. complete. |
| 192 | Supply & ercting ISI mark ceiling rose/ battern holder/ slanting holder/hanging cordswitch/hanging bell push/pendent holder bakelite base 6A errected in filed polypropyene ISI marked (IS: 14772-2000) Boardor polished double wooden block/ ISI mark pvc junction box |
| 193 | Supplying and erecting ISI mark modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. |
| 194 | Supplying and erecting ISI mark modular type switch 16 / 20 A with indicator, duly erected on provided plate and box with wiring connections complete. |
| 195 | Supplying and erecting ISI mark modular type 3 pin 6A multi sockets with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 196 | Supplying and erecting ISI mark modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 197 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 198 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 199 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 4 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 200 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 201 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 202 | Supplying and erecting ISI mark modular type blanking plate one module, duly erected on provided plate & box. |
| 203 | Supplying and erecting ISI mark modular type blanking plate two module, duly erected on provided plate & box. |
| 204 | supplying and erecting PVC Surface Modular switch Box with double mounting plate for 3 module duly erected on provided plate & box. |
| 205 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 4 modules duly erected. |
| 206 | Supplying and erecting PVC Surface modular double mounting plate 12 modules complete duly erected. |
| 207 | Supplying and erecting PVC Surface modular double mounting plate 6 modules complete duly erected. |
| 208 | Supplying and erecting PVC Surface modular double mounting plate 4 modules complete duly erected. |
| 209 | Supplying and erecting PVC Surface modular double mounting plate 3 modules complete duly erected. |
| 210 | Supplying and erecting PVC Surface modular double mounting plate 2 modules complete duly erected. |
| 211 | Supplying and erecting PVC insulated PVC round sheathed 2.5 sq.mm (50 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV |
| 212 | Supply Installation, testing and commissioning of Following Panels. Panels shall be fabricated out of 16 SWG CRCA sheet steel, with necessory structural supports in form of structural steel sections. Panels shall be floor mounted.The panel shall be compartmental type with suitable size of bus bar and separate cable and busbarchambers. The cable chambers shall be free from any live open connections. Multifuction meters for all incoming feeders, Indication lamps for all incoming and outgoing feeders for phase identifications and for indication of Switch status.Panel shall be Indoor type. FORM 3B (IEC-:1999+A1:2004) 16 SWG CRCA ALUMINIUM BUSCURRENT DENSITY :- 1 AMP/1 SQ. MM. ALL CABLES- TOP/ BOTTOM CABLES ENTRIES INCOMER 160A FP MCCB MCCB WITH THERMAL MAGNETIC BASED RELEASE WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION. OUTGOING 1 NO. 125A FP MCCB 1 NO. 16A DP MCB 2 NOS. 25A FP MCB 2 NOS. 40A FP MCB 1 NO. 63A FP MCB |
| 213 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 12 ways /phase (36 poles), with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB |
| 214 | Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB |
| 215 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 12 ways /36 poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB |
| 216 | Supplying, erecting & marking SPMCB 6A to 32A, C-series (for motor/power) in provided distribution board as per specification no. SW-SWR/MCB |
| 217 | Supplying, erecting & marking TPMCB 6 A to 32A in provided distribution board as per specification no. SW-SWR/MCB |
| 218 | Supplying, erecting & marking FPMCB 6A to 32A in provided distribution board as per specification no. SW-SWR/MCB |
| 219 | Supplying, erecting & marking FPMCB 40A to 63A in provided distribution board as per specification no. SW-SWR/MCB |
| 220 | Supplying, erecting & marking TPN MCB 6A to 32A, C- series in provided distribution board as per specification no. SW- WR/MCB |
| 221 | Providing, erecting and commissioning 2 pole RCCB only of electromagnetic type with 30/100/300 mA sensitivity and having capacity of 16/ 25A complete as per specification no. SWRCCB/ RCCB |
| 222 | Providing, erecting and commissioning 2 pole RCCB only of electromagnetic type with 30/100/300 mA sensitivity and having capacity of 40A complete as per specification no. SW-RCCB/RCCB |
| 223 | Supplying, fixing and commissioning 2 pole,RCBO (residual current breaker with overcurrent short circuit 10 kA and earth leakage protection), with 30/100/300 mA sensitivity and having capacity of 6/10/16/20/25A, as per specification no SW-RCCB/RCBO |
| 224 | Supplying, fixing and commissioning 2 pole RCBO (residual current breaker with overcurrent short circuit 10 kA and earth leakage protection), with 30/100/300 mA sensitivity and having capacity of 32A/40A as per specification no SW-RCCB/RCBO |
| 225 | Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 226 | Supplying, erecting & terminating XLPE armoured cable 3½ core 70 sq. mm. aluminium conductor with continuous 8.35 sq. mm. (10 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 227 | Supplying, erecting & terminating XLPE armoured cable 3½ core 25 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 228 | Supplying, erecting & terminating XLPE armoured cable 4 core 16 sq. mm. copper conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 229 | Supplying, erecting & terminating XLPE armoured cable 4 core 10 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 230 | Supplying, erecting & terminating XLPE armoured cable 4 core 6 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 231 | Supplying, erecting & terminating XLPE armoured cable 4 core 4 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 232 | Supplying, erecting & terminating XLPE armoured cable 3 core 4 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 233 | Providing & erecting Hot dipped galvanized ladder type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 300 mm width & 100 mm height comprising all required standard accessories. |
| 234 | Providing & erecting Hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner. |
| 235 | Providing & erecting Hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 200 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner. |
| 236 | Providing & erecting Hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner. |
| 237 | Supplying and erecting PVC box trunking of size 100x50 mm. with accessories on wall/ceiling as per specification No: WG-MA/BOX . |
| 238 | Supplying and erecting PVC box trunking of size 100x38x1.6 mm. with accessories on floor. (1 COM STD LEN 2.5 M) |
| 239 | Supplying, erecting & commissioning junction box suitable for 150 x 150 x 60-75 mm |
| 240 | Supplying and erecting PVC box trunking of size 225x38x1.6 mm. with accessories on floor. (3 COM STD LEN 2.5 M) |
| 241 | Supplying, erecting & commissioning cross over junction box suitable for 250 x 250 x 60-75 mm 3 comp |
| 242 | Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results as per specification no. EA-EP |
| 243 | Supplying and erecting aluminium strip of high purity required sizes used for earthing on wall and/or any other purpose with necessary aluminium clamps fixed on wall painted with bituminous paint with joints required as per specification no EA-EP. |
| 244 | Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no EA-EP. |
| 245 | Supplying and erecting Annealed bare copper wire of high purity of different sizes used for earthing on wall with necessary copper clamps fixed on wall/cable/conduit with screws in an approved manner. |
| 246 | Supplying and erecting GI earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws in an approved manner. |
| 247 | Supplying & erecting on line UPS pure sine wave of 10 kVA capacity complete with standard features, along with necessary SMF batteries for 30 mins battery backup, as per specification no. AP-UPS |
| 248 | Supplying, installing, testing and commissioning of single phase, 230V, 50 Hz, 2500 VA digital pure sine wave inverter with backup time of 15 min. based on Insulated Gate Bipolar Transistor (IGBT) technology complete as per specification no. AP-INV |
| 249 | Supplying and erecting 12V/100Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete. |
| 250 | Subwork III : Supplying and laying HMS PVC conduit FRLS grade 20 mm dia. With necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 251 | Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 252 | Supplying and laying HMS PVC conduit FRLS grade 32mm dia. With necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 253 | Supplying and erecting 20mm dia. corrugated flexible polypropylene conduit |
| 254 | Supplying and erecting 25 mm dia. corrugated flexible polypropylene conduit |
| 255 | Supplying and erecting PVC box trunking of size 100x50 mm.with accessories on wall/ceiling as per specification No: WGMA/BOX . |
| 256 | Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 257 | Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 258 | Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 259 | Supplying and erecting mains with 2x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 260 | Supplying and erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per Note No. 2 & 3 |
| 261 | Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per Note No. 2 & 3 |
| 262 | Supplying and erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per Note No. 2 & 3 |
| 263 | Supplying and erecting mains with 1x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per Note No. 2 & 3 |
| 264 | Supplying and erecting ISI mark modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete |
| 265 | Supplying and erecting ISI mark modular type switch 16A duly erected on provided plate and box with wiring connections complete. |
| 266 | Supplying and erecting ISI mark modular type switch 16 / 20 A with indicator, duly erected on provided plate and box with wiring connections complete |
| 267 | Supplying and erecting ISI mark modular type 3 pin 6A multi sockets with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 268 | Supplying and erecting ISI mark modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 269 | Supplying and erecting ISI mark modular type T.V. socket single outlet, duly erected on provided plate and box with wiring connections complete. |
| 270 | Supplying and erecting ISI marked modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 271 | Supplying and erecting ISI mark modular type computer jack RJ 45 with safety shutter, duly erected on provided plate and box with wiring connections complete |
| 272 | Supplying and erecting ISI mark modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. |
| 273 | Supplying and erecting ISI mark modular type blanking plate one module, duly erected on provided plate & box. |
| 274 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.. |
| 275 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 276 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 277 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 4 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 278 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 279 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 8 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 280 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly rected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 281 | Supplying & erecting co-axial copper cable low voltage grade tri-shielded RG-6 as per specification No. WG-TW |
| 282 | Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC |
| 283 | Supplying and installing cat-6 STP cable suitable for networking complete as per specification. |
| 284 | Supplying and fixing 1 meter length, UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC |
| 285 | Supplying and fixing 3 meter length, UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC |
| 286 | Supplying, fixing, and configuring 24 ports with 4 (SFP+) port, ethernet managed switch with web view/CLI, 6KV surge protection on ethernet port and console port for management in provided rack as per specification no. WGNWC/ GBS |
| 287 | Supplying, fixing, and configuring broadband ADSL router with all accessories, on provided rack as per specification No. WG-NWC/ADSL |
| 288 | Supplying, installing & testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC. |
| 289 | Supplying and fixing tool-less information outlet (ethernet)flush/surface type in provided modular box as per specification no. WG-NAS/IO |
| 290 | Supplying and fixing tool-less shutter keystone jack (RJ-45) in provided Patch Panel complete as per specification no. WGNAS/KJ |
| 291 | Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP |
| 292 | Supplying and fixing 42U floor mount rack (Dimension-DxWxH – 800x600x1866 mm) as per specification No. WGNAS/RAK |
| 293 | Supplying and erecting LED square / circular Max. 11 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 294 | Supplying and erecting LED square / circular Max. 18 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 295 | Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens , min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty. |
| 296 | 35 W LED Recessed mounted light fixture with Dimmable ballast and complete Accessories.Similar to Model No. RS378B P33 940 PSU-E WB M87+RS378Z M87 D125 R-R FX D |
| 297 | 35 W LED Recessed mounted light fixture with ballast and complete Accessories.Similar to Model No. RS378B P33 940 PSU-E WB M87+RS378Z M87 D125 R-R FX D |
| 298 | 70 W LED Recessed mounted light fixture with ballast and complete AccessoriesSimilar to Model No. 2x RS378B P33 940 PSU-E WB M87+RS378Z M87 D245X115 S-2R AJ |
| 299 | LED Flexible Strip Lights of lengh of 1.2 meter with required 25-50 mm Aluminum Profile/Housing and Driver 24 W / Meter with Dimmable ballast and complete Accessories.Similar to Model No. SP780 LED22S |
| 300 | LED Flexible Strip Lights with required Flexible Housing and Driver 12 W / Meter with Dimmable ballast and complete Accessories.Similar to Model No. BGC401 1150 |
| 301 | LED Flexible Strip Lights with required Flexible Housing and Driver 7 W / Meter with Dimmable ballast and complete Accessories.Similar to Model No. BGC401 550 |
| 302 | LED Flexible Strip Lights with required 32-50 mm Aluminum Profile/Housing and Driver 24 W / Meter with Dimmable ballast and complete Accessories.Similar to Model No. SP780 LED22S |
| 303 | Customized Decorative LED Wall Light with ballast and complete Accessories. |
| 304 | Customized Decorative LED Hanging Light with ballast and complete Accessories. |
| 305 | Customized Decorative LED Table/ Floor Lamp with ballast and complete Accessories. |
| 306 | Supplying and erecting regular/ standard model ceiling fan of 1400mm. sweep complete erected in position as per specification no. FG-FN/CF |
| 307 | Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 308 | Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 309 | Supplying & erecting triple pole and neutral distribution board (TPNDB),SP/TP MCBs total 4 ways /12 Poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB |
| 310 | Supplying & erecting triple pole and neutral distribution board (TPNDB),SP/TP MCBs total 8 ways /24 poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB |
| 311 | Supplying & erecting triple pole and neutral distribution board (TPNDB),SP/TP MCBs total 12 ways /36 poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB |
| 312 | Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB |
| 313 | Supplying & erecting CRCA sheet metal one way enclosures suitable for DP MCB /TP MCB /FP MCB erected on angle iron/GI frame complete. |
| 314 | Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/4 pole MCCB as incomer & outgoing SP MCB (36 poles) or TP MCBof 12 ways (36 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1 |
| 315 | Supplying and erecting blanking plate of suitable size on MCB DB complete. |
| 316 | Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB ( With Note 1 ) |
| 317 | Supplying, erecting & commissioning 2 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB |
| 318 | Supplying, erecting & commissioning 2 pole RCCB 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB |
| 319 | Supplying, erecting & commissioning 2 pole RCCB 63A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB |
| 320 | Supplying, fixing and commissioning 2 pole, RCBO 6/10/16/20/25A, withovercurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO |
| 321 | Supplying, fixing and commissioning 4 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO |
| 322 | Supply Installation, testing and commissioning of Following Main Panels. Panels shall be fabricated out of 16 SWG CRCA sheet steel, with necessory structural supports in form of structural steel sections. Panels shall be floor mounted.The panel shall be compartmental type with suitable size of bus bar and separate cable and busbarchambers. The cable chambers shall be free from any live open connections. Multifuction meters for all incoming feeders, Indication lamps for all incoming and outgoing feeders for phase identifications and for indication of Switch status.Panel shall be Indoor type1 No. 200 A, FP, Moulded Case Circuit Breaker µP Based O/C, S/C & E/F 35 KAMETERING & BUSBARS:a) 1 No\"s, Multi-Function Meter with I,V,PF,KWH,KW, KVA, KVAR, THD, F with control MCB\"s, CT\"s etc.b) TPN, EC Grade Aluminium busbars for 200 Amps insulated with heat shrinkable PVC sleeves c) 1 Sets, RYB, indicating lamps + ON, OFF, TRIP Indication (LED based) with 2A MCB on the incomer 1 Nos. 125 A, TPN, Moulded Case Circuit Breaker with O/C, S/C 35 KA1 No. 100 A, TPN, Moulded Case Circuit Breaker with O/C, S/C 35 KA6 Nos. 63 A, FP, Miniature Circuit Breaker 10 KA - C-CurveMETERING/Indication :a) 4 Sets, RYB, indicating lamps, ON, OFF, TRIP Indication (LED based) with 2A MCB on the incomer |
| 323 | Supply Installation, testing and commissioning of Following UPS output Panels. Panels shall be fabricated out of 16 SWG CRCA sheet steel, with necessory structural supports in form of structural steel sections. Panels shall be floor mounted.The panel shall be compartmental type with suitable size of bus bar and separate cable and busbarchambers. The cable chambers shall be free from any live open connections. Multifuction meters for all incoming feeders, Indication lamps for all incoming and outgoing feeders for phase identifications and for indication of Switch status.Panel shall be Indoor1 No. 100 A, TPN, Moulded Case Circuit Breaker with O/C, S/C & E/F 25 KAMETERING & BUSBARS:a) 1 No\"s, Multi-Function Meter with I,V,PF,KWH,KW, KVA, KVAR, F with control MCB\"s, CT\"s etc.b) TP+2N, EC Grade Copper busbars of 100 Amp, insulated with heat shrinkable PVC sleeves c) 1 Sets, RYB, indicating lamps + ON, OFF, TRIP Indication (LED based) with 2A MCB on the incomer 4 Nos. 63 A, FP, Miniature Circuit Breaker 10 KA - D-Curve6 Nos. 25 A, DP, Miniature Circuit Breaker 10 KA - D-Curve |
| 324 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 325 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 35 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 326 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 70 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 327 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 120 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 328 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 2.5 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 329 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 330 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 331 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 332 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 333 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 334 | Providing & erecting Hot dipped galvanized ladder type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 150 mm width & 100 mm height comprising all required standard accessories. |
| 335 | Providing & erecting Hot dipped galvanized ladder type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 300 mm width & 100 mm height comprising all required standard accessories. |
| 336 | Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware. |
| 337 | Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & hardware. |
| 338 | Providing & erecting Hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 500 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner. |
| 339 | Providing & erecting Hot dipped galvanized cover suitable for perforated type cable tray manufactured from 18 swg (1.2 mm thick) GI sheet of 150 mm width & 20 mm height complete with necessary hardware in approved manner |
| 340 | Providing & erecting Hot dipped galvanized cover suitable for perforated type cable tray manufactured from 18 swg (1.2 mm thick) GI sheet of 300 mm width & 20 mm height complete with necessary hardware in approved manner. |
| 341 | Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results as per specification no. EA-EP |
| 342 | Supplying and erecting aluminium strip of high purity required sizes used for earthing on wall and/or any other purpose with necessary aluminium clampsfixed on wall painted with bituminous paint with joints required as per specification no EA-EP. |
| 343 | Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no EA-EP. |
| 344 | Supplying and erecting GI earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary G. I.Clamps fixed on wall/cable/ conduit with screws in an approved manner. |
| 345 | Supplying and erecting copper strip of required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with insulating and non-corrosivebond in an approved manner with required joints As per specification no. EA-EP. |
| 346 | Providing wireman for dismantling the material 2 wireman x 10 days = 2o shifts |
| 347 | Providing mazdoor to assist wireman for dismantling the material 2 mazdoor x 10 days = 2o shifts |
| 348 | Subwork IV : SITC of Biamplified, 2 Way Progressive directivity Array loudspeaker set, with Individual Module Frequency Range of 55 Hz - 18 kHz or better & Continuous Power Handling of >=750W LF + 150W MF-HF. There shall be LF driver of at least 14\" in each module, and 6 compression drivers of 2\" voice coil or better in a CADS Manifold. The mid band crossover point of the speaker shall under 1kHz. The Loudspeaker shall have a Max. SPL (Peak) of >=127 dB or better for LF and 130dB for MF-HF. It should have suitable Drivers for LF and MF/HF with Horizontal dispersion pattern of 100º or better (with multiple waveguide options, Vertical dispersion of the array shall be 60 degrees or better. The Modules shall be of Baltic birch plywood construction with IP55 weather rating. |
| 349 | Supply, installation, testing & Commissioning of coupling plate for line array modules offered above, coupling plates should be supplied from the same OEM of line array speaker for better installation outcome |
| 350 | Supply, installation, testing & Commissioning of OEM supplied array frames/ Hanging/ Mounting arrangement for Suspension of upto 8-10 array modules offered above, Shall offer multiple rigging points for achieving desired pitch settings, |
| 351 | Supply, installation, testing & Commissioning of OEM array frame pull back hardware for extreme pitch angles. |
| 352 | Supply, installation, testing & Commissioning of 18\" arrayable subwoofer having a Freq. Range of 29Hz - 300Hz. It should have an ground stack position Sensitivity of > = 98dB (1W/1m) or more delivering a ground position Max. Calculated SPL(peak) of >=135 db. The loudspeaker should have a nominal impedance: 4ohm or more and continuous AES Power Handling of 1250W or more. Shall be enclosed in Baltic birch plywood with standard Array rigging hardware for Cardioid as well as stacked position. The subwoofer shall have the same footprint as the main array speakers and shall have provision for suspending on top of main LR arrays. |
| 353 | Supply, Installation, testing and commissioning of full range side surround loudspeaker with frequency range of 80Hz-16kHz or better; Sensitivity (SPL / 1W @ 1m) of 91 dB SPL; Driver Size : LF: 1 X 8\", HF: 1 X 1.5\" or better; Max SPL @ 1m of 120 dB SPL or better; Long term power handling of 250W or better; Nominal dispersion of 90°H x 60°V or better Nominal impedance of 8?; Shall offer Optional 100W@100V OEM transformer kit; spekers to be placed for the front seater to bridge the audio gap. |
| 354 | Supply, Installation, testing and commissioning of full range side surround loudspeaker with frequency range of 80Hz-16kHz or better; Sensitivity (SPL / 1W @ 1m) of 91 dB SPL; Driver Size : LF: 1 X 8\", HF: 1 X 1.5\" or better; Max SPL @ 1m of 120 dB SPL or better; Long term power handling of 250W or better ; Nominal dispersion of 90°H x 60°V or better Nominal impedance of 8?; Shall offer Optional 100W@100V OEM transformer kit; speakers to be placed at the stage to coverage the audio on stage (Similar to Bose- RMU 108) |
| 355 | Supply, Installation, testing and commissioning of Control Room head phone for FOH & MOH Monitoring; Semi-open diffuse-field studio headphone, 250 ohms, 3.0 m (9.8 ft.) coiled cable (single sided). |
| 356 | SITC of 8 channel class D Networkable Power amplifier with a Max Output Power of 8x500W@8 ohms, or bridged mode output power of 4x 1000W @ 8/4 ohms. 20Hz - 20 KHz, SNR of 102dB and THD + N of <0.4% with built in protection such as Limiters, Temperature, DC, Short Circuit, Peak Current Limiters, Turn on delay etc. Built in DSP for Matrix routing, Speaker equalization, Delays, Array EQs etc complete with Ethernet Port for Network Control, programming and monitoring. Shall offer optional Network audio connectivity |
| 357 | Supply , installation , testing and comissioning of Digital Sound Processor of AEC capable Digital Sound Processor with at least 12 AEC Mic/Line inputs & minimum 6 analog outputs, 24 Bit A-D and D-A Convertors; Sampling Rate : 48 kHz or better ; THD : < 0.002 % or better ; Channel Separation (Crosstalk) : < 108 dB ; Frequency Response 20 Hz - 20 kHz ; Signal-to-Noise Ratio 90 dB or better ;Dynamic Range > 115 dB; 5 Control Inputs and Outputs or better ; RS-232 and Ethernet Port for third party Control and Monitoring; 64x64 Bidirectional DANTE Audio Networking ports, Shall include standard Connectivity features like VOIP, POTS, USB Audio etc. inbuilt DSP features like Conference room Routers, Input Equalizers, Router, Band Pass filter, Output Equalizer, Delay, Limiters, gates , Source selectors etc. Shall Support at least 15 remote Zone controllers. |
| 358 | Supply, installation,testing and comissioning of Master Controller with Power Supply ; Programmable network controller with display which shall manage System parameters or scene selections ; Source Selection and Volume Controls ; Supports Upto 256 programmable Functions, Multi character backlit display. |
| 359 | Supply, installation,testing and comissioning of single point hoist system which should have load capacity of 1000 Kg, Lifting speed should be 4 meter/minute, Operating voltage should be 230/400V - 50Hz, 208/460V - 60Hz, Protection class should be 55, Motor power at 50 Hz should be 0.66 kW or better; Current consumption at full load should be 1,46 Amp @ 400V, 2,53 Amp @ 230V, Noise level should be 60 dBA, load wheel should be 5 Pocket, Control should be DC and LVC (Minimum 1000kg) |
| 360 | Supply, installation,testing and comissioning of D-shackle having load capacity of 9.5 ton each unit |
| 361 | Supply, installation,testing and comissioning of Steel Rope with Carabiner |
| 362 | Supplying, fixing, and configuring 48 Ports managed gigabit switch 10/100/1000 Mbps + 4 SFP ports erected in provided rack complete.3ad link aggregation |
| 363 | Supply,Installation,Testing & Commissioning of digital mixing console which should have 33 Motor faders (Includes 1 master fader); 48 Input mixing cosole, 20 Aux (8 Mono + 6 stereo) + Stereo + sub buses; Should have 8 DCA groups with roll out; Should have provision for 32 analog XLR/TRS combo mic/line inputs+ 2 analog RCA pin stereo line inputs; Should have minimum 16 analog inputs; 34x34 digital record/playback channels via USB 2.0; should have one expansion slot for audio interface card; Shuodl have provision for dante based Input/Output rack with 16 microphone/line inputs and 8 line outputs; it should be able to controlled from the digital mixing console; both mixing console and I/O rack should be connected with Cat5e Cables to ensure the reduced latency; SHould have provision for the dante based expansion card which can scale up 128 channels (64 Input/64 Outpu) whenever required in future; also customize trolley to mount the 32 channnel mixing console to be supplied which should be as per the site condition. |
| 364 | Supply, Installation, Testing & Commissioning of Wired Vocal Microphone , Transducer type Dynamic Polar pattern (hypercardioid) Frequency response: 50 - 16,000 Hz Nominal impedance 200 ? Connection 3-pin XLR male etc complete with installation as per site requirement. |
| 365 | Supply, Installation, Testing & Commissioning of Instrumenet Microphone with high-frequency reproduction Polar Pattern: Cardioid, Frequency response : 50-17,000 Hz Open circuit voltage : 2.4 mV/Pa, Nominal impedance : 600 ?, Load impedance : = 2 k?, Connection : 3-pin XLR etc. complete with installation as per the site requirement. |
| 366 | Supply, Installation, Testing & Commissioning of Wired Vocal Microphone , Transducer type Dynamic Polar pattern (hypercardioid) Frequency response: 25 - 18,000 Hz Nominal impedance 280 ? Connection 3-pin XLR male etc complete with installation as per site requirement. |
| 367 | Supply, Installation, Testing & Commissioning of array Microphone having shall be used for high-quality conference, paging and PA applications. minimum 20\" length with cardoid polar pattern. A programmable button shall operate in the operating modes ON/OFF, Push-To-Talk and Push-To- Mute. The microphone shall have an excellent RFI shielding and is immune to wireless communication devices. The microphone shall be provided with a 3-pin XLR connector (male).The mic should be supplied with Flexible shockmount fixture for mounting (Similar to Beyerdynamic Classis RM 31 SP + ZSH 20) |
| 368 | Supply, installation,testing and comissioning of DI Box which should have 1 Instrument/Line/Speaker level Input connector; Connection type - 1/4” TS (Tip Hot, Sleeve Ground); Type: Unbalanced, RF Filtered; Should have swithable Attenuation Pad between 0db, 20 dB and 40 dB; Noise Floor should be -112 dBu, 22 Hz to 22 kHz, unweighted; Dynamic Range should be 122 dB, 22 Hz to 22 kHz, unweighted (Similar to DBX DB12) |
| 369 | Supply, Installation, Testing & Commissioning of Digital dual receiver, UHF 470-789 MHz, 19\" metal housing, OLED-display, ethernet and Dante interface, incl. antenna |
| 370 | Supply, Installation, Testing & Commissioning of Wireless Handheld Transmitter, UHF 470-789 MHz, metal housing, OLED-display, charging contacts, without capsule, incl. mic holder, bag and 2 x AA batteries. |
| 371 | Supply, Installation, Testing & Commissioning of Interchangeable microphone capsule (dynamic, hypercardioid) |
| 372 | Supply, Installation, Testing & Commissioning of wireless Beltpack Transmitter, UHF 470-789 MHz, metal housing, OLED-display, charging contacts incl. detachable antenna, 2 belt clips, bag and 2 x AA batteries. |
| 373 | Supply, Installation, Testing & Commissioning of dual channel receiver having frequency response from 45 to 15 kHz; transmission range should be upto 120 meter when line of sight is clear; should have simontaneously active channel upto 18 for per frequency band; Audio dynamic range should be 106dB, should have 2xLCD white backlist display; Should have pilot tone function |
| 374 | Supply, Installation, Testing & Commissioning of handheld transmitter which should have from 45 to 15 kHz, Audio dyanmic range should be 106dB; Display should be LED; Operating time should be 10 hours; Transmitting power should be switchable between 10mW and 50mW; Transmission range should be 120 m when line of sight is clear; SHould have programmable mute button; Syncronization of tranmitter and recevier should be less than one second; Should have pilot tone function |
| 375 | Supply, Installation, Testing & Commissioning of beltpack transmitter which should have from 45 to 15 kHz, Display should be LED; Operating time should be 10 hours; Transmitting power should be switchable between 10mW and 50mW; Transmission range should be 120 m when line of sight is clear; SHould have programmable mute button; Syncronization of tranmitter and recevier should be less than one second; Should have 4-pin male mini XLR connector for microphones or instruments; Should have pilot tone function |
| 376 | Supply, Installation, Testing & Commissioning of Mini condenser lavalier microphone (omnidirectional), black, 6 mm capsule diameter, with 4-pin mini-XLR connector, Should be of similar make of microphones for compatibility reason |
| 377 | Supply, Installation, Testing & Commissioning of Mini condenser neckworn/ Headworn microphone (cardioid), black, with 4-pin mini-XLR connector, Should be of similar make of microphones for compatibility reason. |
| 378 | Supply, Installation, Testing & Commissioning of of NiMH charging device for two handhelds and two Lapel microphone and remote control via Ethernet, Should be of similar make of microphones for compatibility reason (Similar to Beyerdynamic WA-CD) |
| 379 | Supply, Installation, Testing & Commissioning of 6 Way or better Antenna Splitter with range of 400 to 900Mhz, Should be of similar make of microphones for compatibility reason (Similar to Beyerdynamic WA-AS6/2) |
| 380 | Supply,Installation,Testing & Commissioning of Wideband Omnidirectional Antenna with Amplifier range of 400Mhz to 900Mhz, Should be of similar make of microphones for compatibility reason (Similar to Beyerdynamic WA-ATO + WA AMP2) |
| 381 | Supply,Installation,Testing & Commissioning of Mounting kit for Antenna, Should be of similar make of microphones for compatibility reason (Similar to Beyerdynamic MS 50) |
| 382 | Supply,Installation,Testing & Commissioning of standard antenna cable 2.4 GHz, 38 dB attenuation, bend radius 25 mm, 50 metr, Should be of similar make of microphones for compatibility reason (Similar to Beyerdynamic CA 2420-50) |
| 383 | Supply , installation , testing and commissioning of gooseneck microphone with ON/OFF complete with standard accessories as per the tender specifications Sennheiser MEG14- 40B+MAT 133S or equivalent of Shure/ AKG |
| 384 | Supply , installation , testing and commissioning of Hanging microphone complete with standard accessories as per the tender specifications AKG CHM99 or equivalent of Sennheiser/ Shure |
| 385 | Supply , installation , testing and commissioning of Boundry microphone complete with standard accessories as per the tender specifications AKG or equivalent of Sennheiser/ Shure |
| 386 | Supply , installation , testing and commissioning of long microphone stand complete with standard accessories as per the tender specifications Ahuja/ProEL/K&M |
| 387 | Supply , installation , testing and commissioning of short microphone stand complete with standard accessories as per the tender specifications. Ahuja/ProEL/K&M |
| 388 | Supply and laying of 2 core 4 sqmm loudspeaker cable complete with standard accessories as per the tender specifications Krystal/Parasheild or approved equivalent |
| 389 | Supply and Laying 2 core 2.5 sqmm loudspeaker cable complete with standard accessories as per the tender specifications Krystal/Parasheild or approved equivalent |
| 390 | SITC of microprocessor cable which should have 24 AWG stranded( 27x38) Microphone cable or better High conductivity bare copper conductors or better should have PVC insulation Bare copper spiral shield (90% coverage) or better should have PVC jacket Operating temperature range -30 C to +60C or better |
| 391 | Supply and laying of 32 channel Snake cable including end connectors and stage boxes as per the tender specifications Krystal/Parasheild or approved equivalent |
| 392 | Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 393 | Supplying and fixing 42 U floor mount server rack (Dimension-DxWxH – 800x1000x2070 mm) as per specification No. WG-NAS/RAK |
| 394 | Supply,Installation,Testing & Commissioning of other accessories accessories like wire rope slings,Swaged assemblies for the installation microphones set-up |
| 395 | Basic Test of Cement : Carrying out Standard Consistancy Fineness, Specific Gravity, Setting Time (Initial & Final ), Compressive Strength, Soundness Test |
| 396 | FINE AGGREGATES : Carrying out test of Fineness Modulus (Sieve Analysis), Silt & Clay Content |
| 397 | BASIC TEST OF AGGREGATE : Carrying out test of Water Absorption, Specific Gravity. Impact Value, Crushing Value |
| 398 | BRICKS : Carrying out test of Water Absorption (Set of 5 Bricks), Compressive Strength (Set of 5 Bricks), Efflorescence (Set of 5 Bricks). |
| 399 | CERAMIC TILES / VITRIFIED TILES : Carrying out test of Water Absorption, Modules of Rapture (Set of 6 Tiles) |
| 400 | PLYWOOD : Carrying out test of Determination of Resistance to dry heat, Determination of Moisture Content, Determination of Density, Thickness of Plywood, |
| 401 | Royalty Charges for Sand are to be paid to the contractor after producing receipt of royalty paid to the Govt. for the material used for this work. |
| 402 | Royalty Charges for Other Minerals are to be paid to the contractor after producing receipt of royalty paid to the Govt. for the material used for this work. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy