Road And Building Department-RBD has published Tender For Renovation, Restoration And Beautification Of Khirachora Gopinath Temple, Remuna At Balasore In The District Of Balasore For The Year 2023-24.. Submission Date for this Tender is 03-10-2023. Temple Tenders in balasore Odisha. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Earthwork in excavation in all types of soil for site leveling, foundation, pits, trenchesand other civil works upto and including 1.5metre depth and stacking the soil upto a lead of 100 metre and including dewatering, removing slush, shoring and strutting (as required), complete as per specification and as directed by the Engineer-In-Charge. |
2 | Excavation of founation in hard rock (granite) removed by chiselling including dressing and levelling the bed not exceeding 1.5m in depth and depositing the soil within initial lead of 50m and as per specification approved by the Department |
3 | Supplying and filling sand in foundation and over areas including watering, ramming, consolidating and dressing, labours, tools, taxes etc. all complete as per the specification and direction ofEngineer-In-charge. |
4 | Cement concrete of proportion (1:3:6) in foundation and floors using 4cm sizeblack broken granite stone aggregates of approved quality and from approved quarry including hoisting, lowering and laying concrete in layers not exceeding 15cm(6") thick to the required level ramming, watering, curing etc. complete including cost and conveyance royality taxes of all materials and labour with T&P required for the work etc. complete i as per direction of the Engineer-in-charge. |
5 | Providing and laying plain cement concrete 1:4:8 (1 cement : 4 sand : 8 stone agregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curring, shuttering etc. complete all depth and height. |
6 | Filling Foundation and plinth with avelable excavated Earth including leveling and watering, all labour and matrials complete |
7 | First class Fly ash Brick masonry usingbricks of size 25 cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Foundation & Plinth including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-Charge. |
8 | First class Fly ash Brick masonry usingbricks of size 23 cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Super structure including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-Charge. Ground Floor |
9 | First class Fly ash Brick masonry usingbricks of size 25cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:4) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Super structure including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-In-Charge. |
10 | Providing and laying plain cement concrete 1:2:4 (1 cement : 2 sand : 4 stone agregate 12mm nominal size) as levelling course in foundation and plinth etc. including tempering, curring, shuttering etc. complete all depth and height. |
11 | Providing, lifting, hoisting and laying Reinforced cement concrete of M-25 grade as per approved designs and drawings having a minimum compressive strength (in work test) 25 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed andcleaned ( 20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portlandslag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. But excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or tor steel tying the grills and placing in proper position. |
12 | a) Footing Base. |
13 | b) Column |
14 | c) Plinth Beam |
15 | d) Lintel Beam |
16 | e) Chajja |
17 | f) Roof Beam |
18 | g) RCC Slab |
19 | Cutting straightening coiled bent up HYSD bars bending , binding , welding and jointing if necessary and tying the grills and placing in position as required for R.C.C work and for providing fan hooks hoisting lowering and tyingincluding cost , conveyance and taxes ofHYSD barsand binding wires 18 to 20 gauge required for the work and bending binding and tying the grills(payment will be made tow wards the weight of binding ware) . complete as perdirection of the Engineer-in-charge. Ground Floor |
20 | 12mm thick Cement plaster (1:6) for brickwork including curing etc. complete including curing etc. complete. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-Charge. Ground Floor |
21 | 16mm thick Cement plaster (1:6) over brickworkincluding curing etc. completeincluding curing etc. complete. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-Charge. Ground Floor |
22 | 6mm thick Cement plaster (1:4) finished smooth per 1 Sqm.including curing etc. complete including curing etc. complete. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-Charge. Ground Floor |
23 | Providing and laying Vitrifiedfloor tiles 600x600 mm (thickness to be specified by the manufacturer) 1st qualityof NITCO, SOMANY, ASIAN, KAJARIA or equivalent approved make, colours & shades laid on 20 mm thick cement mortar 1:4 (1cement: 4coarse sand ) including pointing the joints with white cement and matching pigments, etc. complete as per direction ofEngineer-In-Charge at all floors and all heights. |
24 | Providing and layingVitrifiedskirting tiles 600x600 mm (thickness to be specified by the manufacturer) 1st quality conforming to IS: 15622 of NITCO, SOMANY, ASIAN, KAJARIA or equivalent approved make, colours & shades, except white, ivory, grey, fume red brown, laid on 12 mm thick cement mortar 1:3 (1cement: 3coarse sand ) including pointing the joints with white cement and matching pigments, etc. complete as per direction of EIC at all floors and all heights. |
25 | Providing and layingMatte Finish Vitrifiedfloor tiles 600x600 mm (thickness to be specified by the manufacturer) 1st quality conforming to IS: 15622 of NITCO, SOMANY, ASIAN, KAJARIA or equivalent approved make, colours & shades, except white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 (1cement:4coarse sand) including pointing the joints with white cement and matching pigments, etc. complete as per direction ofEngineer-In-Charge at all floors and all heights. |
26 | Providing and fixing 1st quality Ceramic glazed wall tilesconforming to IS : 15622 (thickness to be specified by the manufacturer) minimum thickness 5mm of NITCO, SOMANY, ASIAN, KAJARIAor equivalent approved make in all colours, shades except burgundy, bottle green, black of size 300x450mm or 300x200mm in skirting and dados over 12 mm thick bed of cement mortar 1:3 (1 cement : 3coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete as per direction ofEngineer-In-Charge at all floors and all heights. |
27 | Providing and fixing 20mm thick Granite stone flooring (sample of Granite stone should be approved byEngineer-In-Charge) for stair case trade, riser, Toilet Floor and similar locations where ever required in horizontal/vertical surfaces of required size of approved shade, colour and texture, with moulding edge & approved groove pattern etc. laid over 20mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) with joints treated with white cement mixed with matching pigment, epoxy touch ups including rubbing, curing, moulding and polishing to give high gloss finish etc. complete as per direction of Engineer-in-charge. In all floors and all heights. |
28 | Providing & Applying priming one coat with Cement primer of approved brand and manufacture on plaster surface as per the instruction of Engineer-In-Charge at all elevations including all material & labour complete. |
29 | Providing and applying to outside walls with two or more coats ofAnti-Fungal Weather coat water proofing paint including scaffolding and cleaning the surface before application of approved colour and manufacture as per specification, instruction of Engineer-In-charge at all elevations including all material labour complete. |
30 | Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacturer, over the plastered wall surfaces to prepare the surface even and smooth as per the instruction of Engineer-In-Charge at all elevations including all material & labour complete. |
31 | Preparing surface and painting at all height with two or more coats of interior Plastic Emulsion "Royale Shyne" of Asian Paints or equivalent of approvedshade as per the instructions of the manufacturers; giving uniform shade etcin all heights of walls etc. including interiorwall primer & providing scaffolding, cleaning, curing and supply of all materials and labour complete as per drawing, design and direction of Architect/Engineer-In-Charge. |
32 | Providing and fixing seasoned sal wood work in frames at any locations including doors, windows, cupboard, clerestory and other framesfixing in position including cost of hinges, M.S. flat (30mm x 6mm) hold fasts lugs ordash fasteners of required dia and length as per drawing / specification, at all floors and all heights. |
33 | Providing, fitting and fixing ofapproved make 35mm thick (laminate finished thickness of the door) factory made flush doors of the followings size finished with 1mm thk. laminate of approved colour & shade to both side fixed to the teak wood bidding, complete in all respect bidding/lipping as per drawing/design. The door will be provided with all necessary fittings & fixtures, make with all materials, (excluding door Closer) labour, T&P, taxes etc. as per direction of Architect/Engineer-in-Charge. |
34 | Providing and fixing of factory made (NCL/VEKA LTD or equivalent )of colour UPVC sliding window or openable (approved colour of Frame ) complete with U value=1.9-1.3 W/m 2k/3k, flame resistance, self extinguishing, lead free comprising colour UPVC multi chambered frame having in built UPVC roller track on top and UPVC sash with wall thickness of 2.3mm duly reinforced with G.I section 2.6 mm where ever required. All corners of frame and sash will be fusion welded. After placing12.5mm laminate glass (6mm clear toughtened +1.5 pvg laminate+5mm clear glass) Annealed glass in the sash, with suppord of hurricane bar for high wind support. uPVC glazing bead, interlock, EPDM gasket brush shall be provided including multi lock and rollers & proper drainage system shall be provided. window frame will be fixed to the wall with 100mm long and 8mm dia.Fasteners and after fixing the gap between frame and adjucent finished wall shall be filled with weather proof silicon sealant over backer rod of required size, of approved quality complete in all respect as per approved drawing & direction of the Engineer -In-Charge. |
35 | Providing and fixing M.S grill of required patterns for windows/verandahs etc. with M.S flats, square or round bars etc. including applying a coat of approved steel primer and two or more coats of synthetic enamel paint of approved make & shade, all complete as per drawing & specification. (Allsteel sections contractor"s own supply). |
36 | Providing & Painting with synthetic enamel paint of approved brand and manufacture to give an even shade as per the instruction of Engineer-In-Charge at all floors and all heights including all material & labour complete. |
37 | Providing and laying grading conc. 25 mm (avg. thickness) cement concrete of required slope of mix 1:2:2(1cement:2sand:2graded stone aggregate of 6 mm nominal size) mixed with approved water proof compound as per manufacturer"s specification on top of slab including cement slurry, all complete, including the cost of water proofing admixture, which should be approved by the Engineer-In-Charge prior to material procurement by the contractor. |
38 | Providing and applying to outside walls with one coat wall Primer, two or more coats ofAnti-Fungal Weather coat water proofing paintmake & shade manufactured by reputed manufacturer like NEROLAC / ASIAN / BERGER / DULOX or equivalentincluding scaffolding and cleaning the surface before application of approved colour and manufacture as per specification, instruction of Engineer-In-charge at all elevations including all material labour complete at all floors and all heights. |
39 | Carriage of earth by mechanical means with cost of all lead & lift upto 5 km including cost of all labour, T&P etc., comp. |
40 | Fixing Khandolites (Up to 0.06 Sqm.) 20mm thick bed of cement mortar 1:4 (1 cement : 4 sand) jointed with neat cement slurry mixed with pigment to match the shades on the tiles etc. complete. |
41 | Providing and fixing 25mm thick Khandolite stone Skirting & Cladding(sample of Khandolite stone should be approved byEngineer-In-Charge) for slope Slab, wall and similar locations where ever required in horizontal/vertical surfaces of required size of approved shade, colour and texture, with moulding edge & approved groove pattern etc. laid over 12mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand) with joints treated with white cement mixed with matching pigment, epoxy touch ups including rubbing, curing, moulding and polishing to give high gloss finish etc. complete as per direction of Engineer-in-charge. In all floors and all heights. |
42 | Providing and fixing Best quality Khandolite stone Carved Pieces in required sizes of Minimum Thickness of 50mm with carving, Moulding work upto a depth of 25mm, as given in reference drawing, neatly carved and finished including all necessary M.S. clamps, dowels etc all complete as per approved drawings, specifications and directions of the Engineer-In-Charge, including Cost of Material, Conveyance etc. complete. ( The Contractor should approve the final sketch in accordance with the drawings and specifications provided, before executing the same from concerned Architect & Engineer-in-charge) |
43 | Providing and fixing Best quality Khandolite stone Carved Pieces in required sizes of Minimum Thickness of 50mm with carving, Moulding work upto a depth of 100 mm, as given in reference drawing, neatly carved and finished including all necessary M.S. clamps, dowels etc all complete as per approved drawings, specifications and directions of the Engineer-In-Charge, including Cost of Material, Conveyance etc. complete. ( The Contractor should approve the final sketch in accordance with the drawings and specifications provided, before executing the same from concerned Architect & Engineer-in-charge) |
44 | Providing and fixing Best quality 75mm thick Khandolite stone Jalli Pieces of approved design/Pattern by Architect & EICas given below, neatly carved and finished inlcuding all necessary M.S. clamps, dowels etc. all complete as per approved drawings, specifications and directions of the Engineer-In-Charge, including all Cost of Material, Labour, Conveyance etc. complete. |
45 | Providing and fixing Best quality Khandolite stone Plane Pieces in required sizes of Minimum Thickness of 50mm with Moulding as given in reference drawing, neatly carved and finished including all necessary M.S. clamps, dowels etc all complete as per approved drawings, specifications and directions of the Engineer-In-Charge, including Cost of Material, Conveyance etc. complete. (The Contractor should approve the final sketch in accordance with the drawings and specifications provided, before executing the same from concerned Architect & Engineer-In-charge) |
46 | Providing and fixing Best quality Khandolite stone Plane Pieces in required sizes of Minimum Thickness of 75mm with Moulding as given in reference drawing, neatly carved and finished including all necessary M.S. clamps, dowels etc all complete as per approved drawings, specifications and directions of the Engineer-In-Charge, including Cost of Material, Conveyance etc. complete. (The Contractor should approve the final sketch in accordance with the drawings and specifications provided, before executing the same from concerned Architect & Engineer-In-charge) |
47 | Providing and fixing Best quality Khandolite stone Plane Pieces in required sizes of Minimum Thickness of 100mm with Moulding as given in reference drawing, neatly carved and finished including all necessary M.S. clamps, dowels etc all complete as per approved drawings, specifications and directions of the Engineer-In-Charge, including Cost of Material, Conveyance etc. complete. (The Contractor should approve the final sketch in accordance with the drawings and specifications provided, before executing the same from concerned Architect & Engineer-In-charge) |
48 | Providing and fixing khandolite thick min 50 mm stone flooring for View Point, floor, and similar locations where ever required in horizontal/vertical surfaces of required size of approved shade, colour and texture, with moulding edge etc. laid over 20mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement mixed with matching pigment, epoxy touchincluding rubbing, curing, moulding and polishing to give high gloss finish etc. complete as per direction of Engineer-In-Charge, In all floors and all heights. |
49 | Providing and fixing Best quality Khandolite stone Carved Pieces in required sizes of Minimum Thickness of 150mm with carving, Moulding work upto a depth of 100 mm, as given in reference drawing, neatly carved and finished including all necessary M.S. clamps, dowels etc all complete as per approved drawings, specifications and directions of the Engineer-In-Charge, including Cost of Material, Conveyance etc. complete. ( The Contractor should approve the final sketch in accordance with the drawings and specifications provided, before executing the same from concerned Architect & Engineer-in-charge) |
50 | Providing and fixing Best quality Khandolite stone Plane Pieces in required sizes of Minimum Thickness of 150mm with Moulding as given in reference drawing, neatly carved and finished including all necessary M.S. clamps, dowels etc all complete as per approved drawings, specifications and directions of the Engineer-In-Charge, including Cost of Material, Conveyance etc. complete. ( The Contractor should approve the final sketch in accordance with the drawings and specifications provided, before executing the same from concerned Architect & Engineer-in-charge) |
51 | Providing and fixing Khandolite stone decorative Elephants Head Hand wash point as per architectural drawing with carving depth and size as specified in drawing or as directed by Project Architect including fixing the same etc. all complete |
52 | Add P.H & Sanitary Work |
53 | Landscaping Earth work in Stoney earth for small trees with initial lead and lift including rough dressing in layers not exceeding 0.3m in depth of size 0.2x0.2x0.2 m. @ 138.71/cum and the Earth transported by transport vehicles as directed by the Engineer-in-charge. |
54 | Earth work in Ordinary soil for big trees with initial lead and lift including rough dressing in layers not exceeding 1m in depth of size 0.60mx0.60mx0.75 m. @ 138.71/cum and the Earth transported by transport vehicles as directed by the Engineer-in-charge. |
55 | Filling pits with fertile soil/ silt including carriage up to each pit by tractor/ truck up to site and by head load up to pit. A.Pit size0.2x0.2x0.2 m |
56 | B) Pit size 0.60mx0.60mx0.75 m |
57 | Application of organic manure (FYM/cimpost/sludge) Including carriage upto pit By tractor/truck upto site and by head lord upto pit. A. Pit size0.2x0.2x0.2 m |
58 | B) Pit size 0.60mx0.60mx0.75 m |
59 | Application of chemical fertilisers npk and insecticited/termicide including cost of materials/carriage and cost of application. A. Pit size 0.20mtx 0.20mtx0.20mt @ 50gm of NPK and 10gm of termicides |
60 | B.) Pit size 1.00mtx 0.60X0.60X0.75 cum @ 50gm of NPK and 10gm of termicides |
61 | Cost of planting including mixing of manure, fertilizer, pesticides and initial watering.A. For shrub category |
62 | B.) For tree category |
63 | Supporting plants with stakes including cost of stakes. A. For shrub category |
64 | B.) For tree category |
65 | Replanting of Trees of by Uprooting and Digging Pits. A. For shrub category |
66 | B.) For tree category |
67 | Supply, Filling, Spreading of Good earth, Garden Soil including cost of material, carriage, labour and cost of application. Lawn area |
68 | Contingent expenditure including cost of ropes, implement,baskets, drums etc. |
69 | Cost of planting trees & palm including transportation upto site ( including Providing, Laying,loading, unloading, transportation, royalties, cost of all materials, labour, sundries, T&P, scaffolding, watering and curing etc. complete in all respect as per specification and direction of Engineer-in-charge. ) Trees Hibiscus tiliaceus variegated |
70 | Cassia nodosa |
71 | Sterculia alata |
72 | Bombax ceiba |
73 | Spathodea campanulata |
74 | Bauhinia blackae |
75 | Azardirachta indica |
76 | Melia azardirach |
77 | Podocarpus macrophyllus |
78 | Plumeria alba |
79 | Plumeria Thai varieties |
80 | Michelia champaca |
81 | Albizia lebbeck |
82 | Arecanut palm |
83 | Raphis palm |
84 | Foxtail Palm |
85 | Arenga palm |
86 | Bottle palm |
87 | Veitchia golden |
88 | Kentia palm |
89 | Cost of planting shrubs including transportation upto site ( including Providing, Laying,loading, unloading, transportation, royalties, cost of all materials, labour, sundries, T&P, scaffolding, watering and curing etc. complete in all respect as per specification and direction of Engineer-in-charge) Small Palms Bauhinia tomentosa |
90 | Bauhinia acuminata |
91 | Tecoma gaudichaudi |
92 | Calliandra haematocephala rubra |
93 | Calliandra haematocephala rosea |
94 | Calliandra brevipes |
95 | Limonia spectabilis variegated |
96 | Limonia spectabilis |
97 | Cassia biflora |
98 | Murraya exotica |
99 | Alpinia zerumbet |
100 | Malphigia golden |
101 | Malphigia green |
102 | Malphigia variegated |
103 | Dracaeana Mahatma red |
104 | Ixora Thai pink |
105 | Ixora Thai red |
106 | Ixora Thai yellow |
107 | Ixora Thai White |
108 | Plumbago capensis |
109 | Acalypha rosea |
110 | Alternathera spp red/yellow |
111 | Iresine herbestii |
112 | Cuphea hyssopifolia |
113 | Lantana sellowiana |
114 | Lantana depressa red/yellow |
115 | Ipomoea green |
116 | Ipomoea Purple |
117 | Serissa foetida |
118 | Monstera spp |
119 | Money plant large leaved |
120 | Mini tagar |
121 | Mini tagar variegated |
122 | Areca Palm |
123 | Allamanda dwarf |
124 | Graptophyllum spp |
125 | Eranthemum tricolor |
126 | Justicia variegated |
127 | Barleria cristata |
128 | Verbena perennial |
129 | Abelia variegated |
130 | Clearance of site, excavation of around upto a depth of 30cm, removal of excavated materials to outside for dumping at suitable places. |
131 | Providing and laying Neelgiri /Mexican grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light waterning with sprinkler and maintenance for 30 days or more till the grass establish properly, as per direction of officer-in-charge. |
132 | Providing and laying Bermuda grasswith earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light waterning with sprinkler and maintenance for 30 days or more till the grass establish properly, as per direction of officer-in-charge. |
133 | Dismantling brick or stone masonry in lime or cement mortar under 3m. height including stacking the useful materials for reuse and removing the debris within 50m. Lead |
134 | Dismantling and removing cement concrete including stacking the useful materials for reuse and removing the debris within 50m lead |
135 | Dismantling and removing R.C.C. columns beams slab staircase landing lintels including stacking the useful materials for reuse and removing the debris within 50m lead |
136 | Dismantling and removing old tiled flooring including removing the base coarse and stacking the useful materials for reuse and removing the debris within 50m lead. |
137 | Dismantling and removing old cladding from walls including racking out joints 12mm deep stacking the useful materials for reuse and removing the debris within 50m lead. |
138 | Dismantling and removing doors, windows and ventilators including removal of frame, hinges, fastening and stacking the same for reuse and removing the debris within 50m lead. |
139 | Dismantling G.C.I. or A.C. sheet roofing after carefully removing the bolts and nuts including stacking of he materials for reuse and removing the debris within 50m lead. |
140 | Dismantling G.C.I. or A.C. sheet roofing after carefully removing the bolts and nuts including stacking of he materials for reuse and removing the debris within 50m lead. |
141 | Electricl Installation Recessed wiring to light point / first light of group control/ call bell point/ exhaust fan point /wall fan point with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVCconduit with 6 Amp, 250 V clip in type switch ISI marked and ceiling rose ISI marked mounted on G.I modular box with face plate & cover of suitable size ,with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. (Make of wire Finolex /Polycab/ Anchor / Havels/Eq.) (Make of modular box,cover,switch & socket-Legrand Myrios/schneider opale/Eq.)With 10years warenty. Group C |
142 | Recessed wiring to secondary light pointlooped from primary light point with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVCconduitwith 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor for running earth including3 plate ISI marked Ceiling rose with all accessories & connection as per direction of Engineer-in-charge. (Make of wire Finolex /Polycab/ Anchor / Havels/Eq.)Average Length: 3mtr |
143 | Recessed wiring to ceiling fan point with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVCconduit with 6Amp 250V Modular Switch,Stepped type Moudular Regulator, Base & Cover with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor for running earth including all accessories & connection as per direction of Engineer in charge. (Make of wire Finolex /Polycab/ Anchor / Havels/Eq.)Group B |
144 | Recessed wiring to Twin control light pointwith 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVCconduit with 6Amp, 250 V clip in type 2way switch ISI marked and ceiling rose ISI marked mounted on G.I modular box with face plate & cover of suitable size ,with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer-in-charge. (Make of wire Finolex /Polycab/ Anchor / Havels/Eq.)Group C |
145 | Recessed wiringfor 5 / 6 amp socket outletwith6Amp, 250 V clip in type modular switch ISI markedmounted on G.I moular box with face plate & cover of suitable sizeincluding all accesories and connection on same switch board as per direction of Engineer-in-charge. |
146 | Recessed wiringfor 5 / 6 amp socket outlet with 2 x 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVCconduit with 6Amp, 250 V clip in type switch ISI markedmounted on G.I moular box with face plate & cover of suitable size ,with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection on separate board as per direction of Engineer-in-charge.(Make of wire Finolex /Polycab/ Anchor / Havels/Eq)Group C |
147 | Recessed wiringfor2 x 6 amp socket outlet controlled by 2 nos6Amp, 250 V clip in type switch ISI markedmounted on single G.I moular box with face plate & cover of suitable sizeincluding all accesories and connection on separate board as per direction of Engineer-in-charge. |
148 | Recessed wiringfor 6 pin 16 amp socket outletwith 16Amp, 250 V clip in type switch ISI markedmounted on G.I moular box with face plate & cover of suitable sizeincluding all accesories and connection as per direction of Engineer-in-charge. 25Nos for Stage Light,3Nos For Aquaguard. |
149 | Recessed wiring to exhaust fan/Wall Fan point with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVCconduit with 6Amp 250V Modular Switch, Base & Cover with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor for running earth including all accessories & connection as per direction of Engineer in charge. (Make of wire Finolex /Polycab/ Anchor / Havels/Eq)Group B |
150 | Recessed wiring to submain in 2 x 6 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 25 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 4 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire as equired. (Make of wire Finolex /Polycab/ Anchor / Havels/Eq) |
151 | Recessed wiring to submain in 2 x 4 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 2.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire as equired. (Make of wire Finolex /Polycab/ Anchor / Havels/Eq) |
152 | Recessed wiring to submain in 2 x 2.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire as equired. (Make of wire Finolex /Polycab/ Anchor / Havels/Eq) |
153 | Recessed wiring to submain in 2 x 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire as equired. (Make of wire Finolex /Polycab/ Anchor / Havels/Eq) (For Switch Board Looping) |
154 | Supply, fixing, erecting, connecting and commissioning of indoor type dust and vermin proof, sheet steel clad ready made, double door horizontal type powder coated wall mounted4 way TPN Distribution Boards For LDB suitable for 440 V, three phase, 4 wire 50 Hz AC Supply completewith bottom detachable plate for interconnections etc as below.Incommer 1 No-40A4PMCB (10KA)Outgoings-6 A SP MCB 10KA- 12 Nos,(Make-L&T/ Schneider/Hager/Legrand/eq) |
155 | Supply, fixing, erecting, connecting and commissioning of indoor type dust and vermin proof, sheet steel clad ready made, double door horizontal type powder coated wall mounted4 way TPN Distribution Boards For PDB suitable for 440 V, three phase, 4 wire 50 Hz AC Supply completewith bottom detachable plate for interconnections etc as below.Incommer 1 No-63A4PMCB (10KA)Outgoings-16/20 A SP MCB 10KA- 12 Nos,(Make-L&T/ Schneider/Hager/Legrand/eq) |
156 | Supply, fixing, erecting, connecting and commissioning of indoor type dust and vermin proof, sheet steel clad ready made, double door horizontal type powder coated wall mountedDP Encloser Box For Shop DB suitable for 220 V, single phase, 3 wire 50 Hz AC Supply completewith bottom detachable plate for interconnections etc as below.Incommer 1 No-20ADPMCB (10KA).(Make-L&T/ Hger/Schneider/Legrand/Eq) |
157 | Supply, fixing, erecting, connecting and commissioning of indoor type dust and vermin proof, sheet steel clad ready made, double door horizontal type powder coated wall mounted12 Way SPN DB For BDB suitable for 220 V, single phase, 3 wire 50 Hz AC Supply completewith bottom detachable plate for interconnections etc as below.Incommer 1 No-40ADPMCB (10KA) & 10/20A SP MCB 10KA-10Nos.(Make-L&T/ Hger/Schneider/Legrand/Eq) |
158 | Supply & Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of4 core 16 sq.mm Aluminium on surface as required.(Make-polycab/RR Kable/Rhino cable/Eq) |
159 | Supply & Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of3 core 6 sq.mm Copper on surface as required.(Make-polycab/RR Kable/Rhino cable/Eq) |
160 | Supply & Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of3 core 4 sq.mm Copper on surface as required.(Make-polycab/RR Kable/Rhino cable/Eq) |
161 | Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as required. 4C x 16 sq.mm |
162 | Earthing with copper earth plate 600 mm x 600mm x 3.15 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc with charcoal and salt as required. |
163 | Supplying and laying 25 mm x 6 mm CU earth strip ISI marked at 0.5 meter below ground level as strip earth electrode including soldering etc. as required. |
164 | Supplying and laying 25 mm x 6 mm CU earth strip ISI marked on surface or in recess for connection etc as required. |
165 | Providing and fixing 8 SWG CU wire on surface or in recess for loop earthing as required. |
166 | Supply & fixing of lightning arrester of size 2.6" length made of 0.5"diameter copper rod, over which 5nos 5" length pointed copper rods of 0.3" diameter with suitable size of nuts and bolts. |
167 | Supplying and laying 25 mm x 6 mm CU earth strip ISI marked on surface or in recess for connection etc as required. |
168 | Earthing with copper earth plate 600 mm x 600mm x 3.15 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc with charcoal and salt as required. |
169 | Supply, Installation, Testing and Commissioning of pre-wired fluorescent fiiting / compact fluorescent fitting /LED fitting of all sizes complete with all accessories and lamp etc. directly on ceiling /wall or recessed in false ceiling , including connection with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor and earthing as required.Make-JAQUAR/philips/wipro/Bajaj/Equivalant. Ceiling mounted18W LED Square Recessed/Surface light Similar to JAQUAR Cat No. LNEP01S018XCor equivalent. |
170 | Ceiling/ Wall mounted typeBULK HEADLuminaire withSimilar to JAQUAR Cat No.CWLL01V109XX or equivalent. |
171 | Supply, Installation, testing and commissioning of ENTRY EXIT LIGHT Double side LED SIMILAR TO BAJAJ CAT. NO-BESL 03 LED DSD WBB GREEN /Equivalent. |
172 | Supply, Installation, Testing and Commissioning of ceiling fan 1200mm sweep, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated single core multiatrand copper conductor etc. as required. |
173 | Ceiling mounted indoortypebatten typeLED Luminaire with LED Lamp Similar to JAQUAR Cat No. LGLZPCX022XWor equivalent. |
174 | Supply, Installation, testing and commissioning of WALL Light similar to Jaquar cat no-330.00.NGG / Equivalent. etcas required. |
175 | Supply, Installation, testing and commissioning of Pendent Light similar to Jaquar cat no-JNL-WHT-SLPEA034AE27 / Equivalent. etcas required. |
176 | Ceiling mounted2W LEDRecessed/Surface Spotlight Similar to JAQUAR Cat No. LSPT06R002XWor equivalent. |
177 | Supply, Installation, testing and commissioning of 70W LED Flood Light similar to Jaquar cat no-LFLDSLM070XC / Equivalent. etcas required. |
178 | Supply, Installation, testing and commissioning of METAL BODY High Speed Wall fan of 450 mm sweep, etcas required.TURBO 180 METAL |
179 | Supply and installation of Rubber Mats 12mm thick of size 2000mm x 1000mm x 12 mm thick Electrical tested with test certificate. |
180 | Supply and fixing of fire buckets with angular fabricated stand to fix 4 buckets in each stand for Electrical fire protection as per standards of Electrical Inspectorate. |
181 | Supply and fixing of Co2 fire extinguisher with mounting clamps with pressure test certificate . |
182 | Supply and fixing of shock treatement charts duly laminated along with separate colour single line diagram laminated, to be fixed in Electrical control panel room. |
183 | Supply and fixing of first aid box with medicines complete with medicine with three years expiry date to be fixed in Electrical control panel room. |
184 | High Quality Canara RGBW LED Linear wash Light Power : 36W CCT : RGBW Beam Angle : 10°/15°/20°/30°/60° Input Voltage: 100-240V AC Control : DMX512 Body : Aluminium Extrusion Dimensions: 1000mm IP66 |
185 | High Quality Canara RGBW LED Spot Light Power : 40W CCT : RGBW Beam Angle : 15°/24°/30°/45°/60° Input Voltage: 100-240V AC Control: DMX512 Body : Die cast Aluminium IP66 |
186 | High Quality Canara RGBW LED Flood Light Power : 60W CCT : RGBW Beam Angle : 15°/24°/30°/45°/60° Input Voltage: 100-240V AC Control: DMX512 Body : Die cast Aluminium IP66 |
187 | High Quality Canara LED Flood Light Power : 80W CCT : RGBW Beam Angle : 10°/15°/30°/45°/60° Input Voltage: 85-265V AC Body : Die cast Aluminium IP66 |
188 | High Quality Canara LED Flood Light Power : 200W CCT : RGBW Beam Angle : 10°/15°/30°/45°/60° Input Voltage: 85-265V AC Body : Die cast Aluminium IP66 |
189 | 8 Channel opto isolated DMX signal Amplifier and Splitter |
190 | Digital Lighting Console with 1024 DMX channels • 1024 Channels. • 96 Fixtures. • 96 Dimmer Control Channels. • Time control of scenes: Fade in/out, LTP slope • Channels for each fixture 40 primary + 40 fine tune • LCD display with back light • 600 Scene step • 60 Scenes/Playbacks • 10 Scenes to run simultaneoulsy • Shape generato: Shapes of Dimmer, Pan/Tilt, RGB, CMY, Color, Gobo, Iris and Focus • Master slider - Global, playback, fixture • USB Memory - FAT32 supported Make : Canara |
191 | Waterproof Power Connectors for Light Fixture |
192 | Waterproof DMX Connectors for Light Fixture |
193 | PVC Copper unarmoured flexible FRLS insulated multicore cable 1100V grade confirming to IS694 size 3cx1.5 sq mm. Make : SBEE, KEI, Polycab, Walna |
194 | PVC Copper unarmoured flexible FRLS insulated multicore cable 1100V grade confirming to IS694 size 3cx2.5 sq mm. Make : SBEE, KEI, Polycab, Walna |
195 | Screened 4 core sheilded DMX signal cable for DMX network. Make : Deepcab, Falcon, Belden, Guru Astronics |
196 | 12 way Direct Lighting Distribution Board with TPN incomer of suitable rating and and outgoing SP MCBs of suitable rating Make : Canara, ABB, L&T, Havells |
197 | Other accessories like Junction Boxes, nuts bolts clamps, conduits etc required for complete installation of the system |
198 | Installation Testing and Commissioining of the system |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy