Tender For Repair And Maintenance Of Winter Appliances And Ac Plants Under Ge (W) Jrc, jalandhar-Punjab

Military Engineer Services-MES has published Tender For Repair And Maintenance Of Winter Appliances And Ac Plants Under Ge (W) Jrc. Submission Date for this Tender is 05-10-2023. HVAC Tenders in jalandhar Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

39705335
Tender For Repair And Maintenance Of Winter Appliances And Ac Plants Under Ge (W) Jrc
Open Tender
Indian
Punjab
jalandhar
05-10-2023

Tender Details

Tender For Repair And Maintenance Of Winter Appliances And Ac Plants Under Ge (W) Jrc

Key Value

Document Fees
INR 500 /-
EMD
INR 50000.0 /-
Tender Value
INR 25 Lakhs /-

BOQ Items

Name of Work:REPAIR AND MAINTENANCE OF WINTER APPLIANCES AND AC PLANTS UNDER GE (W) JRC
Sl. No. Item Description
1Taking down carefully aluminium / copper point wiring (light / fan / socket or power) complete including fitting such as switches, ceiling roses, socket, light fittings, regulators etc complete and making good disturbed surfaces of walls, floors
2M&L for taking down unserviceable geyser of capacity 25 litre storage type, disconnecting necessary connection for repairing including re-fixing the same after repair & reconnection & testing as directed. Note :Thermostat switch, Geyser assembly, Geyser elements, bottom cover etc. if replaced shall be measured and paid separately under respective items.
3All as per srl item No 02 here-in-before but geyser of capacity 50 litres complete all as specified and as directed.
4Attending complaint for rectification of defects of Geyser and making the Geyser ready for re-use (All spare parts, wire, plug etc.) will be measured and paid for separately under respective items here-in- after all as specified and as directed. NOTES:-(i) Rate quoted deemed to be inclusive of necessary T&P, ladder, Vehicle and desired numbers of well qualified persons with attendant having sufficient experience of work for electrical equipment’s fittings and fixture. (ii)The safety of persons/helpers engaged in execution of this item shall be solely responsibility of the contractor and necessary insurance of these persons should be done and copy of same should be submitted to GE. iii) All measurements shall be recorded indicating Complaint No., date, Location, Date of redressal with regard to Quantity. (iv)Contractor shall employ minimum 02 x Elect with Helper to attend complaints of married & OTM accn from 0900 hrs to 1730 hrs including sunday & holiday.
5Repair to steel inner tank of capacity 200 litre to 500 litre capacity after removal from solar heater and further disconnecting off aluminium foil and glass wool and re-assembling the same after repair and re-fixing in position complete all as specified and as directed.
6Providing labour for servicing and maintenance of complete solar water heaterof various capacities installed at single/double/triple storey bldgs. for plugging leakages, by gas welding, brazing’s, Copper plates, tubes, trays and hot water tank , cleaning of flat plate collector glass & cleaning of Water storage tank and make up tank, including dismantling inlet and out let connections and re-fixing the same after cleaning for proper functioning to maintain proper water temperature complete all as specified and as directed. Note : All nessary minor items such as Tee, elbow, Nipple, union, piece of rubber pipe etc. shall be included in item rate quoted by the contractor.
7Supply and fix in replacement 15mm bore steel water tubes medium grade galvanized with and including all fittings , guties/saddles etc. including making connections mixing arrangement of hot/cold water and fixed to wall and ceiling or laid in floor with all fittings complete all as specified and as directed.
8Supply and fix in replacement 20mm bore steel water tubes medium grade galvanized with and including fittins with guties/saddles etc. including making connections mixing arrangement of hot/cold water and fixed to wall and ceiling or laid in floor with all fittings complete all as specified and as directed.
9Supply and fix in replacement 20 mm bore gun metal gate valve both end screwed for pipe fixing with brass spindle and crutch/butterfly handle at top complete all as specified and directed.
10Supply and fix in replacement temperature gauge range 0 to 100 as per existing size all as specified and directed by Engr-in-Charge.Make : AMCO/YENKAY
11Supply and fix in replacement; toughed glass of collector of size 4mm thick and of size 6" x 4" as per existing arrangement complete all as specified.
12Supply and fix in replacement float valve assembly made out of gun metal for 15mm dia pipe complete all as specified.
13Supply and fix in replacement float valve assembly made out of gun metal for 20mm dia pipe complete all as specified.
14Supply and fix in replacement Geysers assembly of stainless steel along with PVC rubber washer suitable for Geyser of Capacity 25 litres any make as requiredincluding taking out the old unserviceable assembly from the geysers complete all as specified and as directed.
15Supply and fix in replacement Geysers assembly of stainless steel along with PVC rubber washer suitable for Geyser of Capacity 50 litres any make as requiredincluding taking out the old unserviceable assembly from the geysers complete all as specified and as directed.
16Supply and fix in replacement heating element 2000 watts of suitable shape/size(cup type/traingle type/Threaded type) with PVC/ rubber washer & clampincluding taking out the old unserviceable heating elementfrom the geysers complete all as specified and directed. Make: Thermo king/Theeta/Daspass/ Lazer.
17Supply and fix in replacement Geyser assembly along with heating element 2000W & Thermostatas required for Geyser of capacity 25 Ltr and Make : Bajaj / as per Sample complete all as specified and directed.
18Supply and fix in replacement; anchor fastner of size 75mm long 8mm dia complete with nut and washers for fixing geyser’s complete all as specified and as directed.
19Supply and fix in replacement; thermostat switch suitable for storage type Geysers 25/50 ltr as required shape and size complete including taking out the old unserviceable switchfrom the geysers complete all as specified and as directed. Make: Bajaj / Recold / Ditz /Sphere top.
20Supply and fix in replacement Neon lamp indicator red/green colour of circular/rectangular shape as suitable and as per sample including taking out the old unserviceable lampsfrom the geysers complete all as specified and as directed.
21Supply and fix in replacement non-return valve 15mm dia of brass including taking out the old unserviceable valve from the geysers complete all as specified and as directed.
22Supply and fix in replacement PVC connection 45cm (confirming to ISI)long wire woven with nickel plated brass adopter, both side threaded in standard length to suit the geyser assembly for 15mm bore including taking out the old unserviceable connection complete all as specified and as directed.
23Supply, hoist and fix in position 500 litres capacity rotational moulded polythene water storage tank (cylindrical, vertical with closed top) ISI marked (Name of firm embossed or engraved on the body of tank) conforming to IS 12701, triple layered complete all as specified.
24Material and Labourfor Point wiring with2.5 Sq.mm (nominal area) single core PVCinsulated unsheathed FRLS cable, multi-stranded, copper conductor, with universal colour code in existing conduit with existing sunk pressed steel terminal boxes providing 3 mm thick plastic laminated sheet top cover or as existing including PVC insulated copper conductor earth wire of 2.5 Sq.mm size in green colour, cutting chases andmaking good the disturbed surfaces in cement mortar 1 : 3 complete all asspecified & directed by the Engineer-in-Charge. (Switch/ Socket are to be measured and paid separately)
25Supply and fix in replacement; sheet metal enclosure with socket plug top, single pole and neutral with a two pin earth plug and socket complete with one single pole MCB-20 Amps 240 Volts including taking out the old unserviceable sheet metal enclosure complete all as specified and as directed.
26Supply and fix in replacement;socket outlet flush type 2-in-1, 6pins, 15 Amps multipurpose includingtaking down old unserviceable socketfrom the existing board complete all as specified and directed.
27Supply and fix in replacement; top plug, 3 Pin, 15 Amps including taking down old unserviceable top plug complete all as specified. Make : Havells/ SSK/ Anchor
28Supply and fix in replacement switch piano flush type 15 Amps, single pole one-way, includingtaking down old unserviceableswitch from the existing board complete all as specified and directed.
29Supply and fixing in replacement; 3 core flexible copper conductor cable of size 2.5 Sq.mm ISI marked including taking out the old unserviceable cable complete all as specified and directed.
30Supply and fixing in replacement; solar water heating element, cup type 3000 watts of suitable shape/size conforming to ISI with PVC/ rubber washer & clamp including taking out the old unserviceable heating element from the solar water heater complete all as specified and directed. Make : Thermo king/ Theeta/Daspass /Lazer
31Supply and fixing socket plug top suitable for metal socket 20 Amps including taking down old one omplete all as specified and as directed. Make : Havells/ Indo Asian/ Anchor
32Supply and fixing aluminium service cable PVC insulated flat or circular of size 10 Sqmm 2 Core complete all as specified and directed.
33Material and labour for de-scaling of condenser unit37.5 TR AC central type with copper tubes by removing nuts & bolts, side cover plates, water connection and filling up of de-scaling chemical in condenser and manually cleaning of copper tubes with using Nylon brush of superior quality, iron rod for removing of complete scaling from tubes and water circulation through condenser including replacement of rubber gasket, tightening side cover plates and making necessary connectionscomplete all as specified and as directed. (UG Ops HQ 11 Corps AC Plant )
34M&L forservicing of Air handling unitof central AC plant 37.5 TR by removing filters, assembling filters and testing for the following parts. (a)Inspectfilters, removing and cleaning by using vaccum cleaner and refix same. (b) Clean cooling coil, fins byusing caustic soda and water pressure method and applying Grease for all motors, check and adjust belt tension if required, check condition of blower shaft, impeller and bearings, check tightness of all electrical terminations, clean water line strainers, check proper balancing system , check for noise and vibration. (c)Check healthy operation of controls and safety devices.
35Attending breakdown(except periodical maintenace) by skilled Ref Mechanic from OEM/authorised dealer for any type AC plant/cold store of capacity 5 TR to 37.5 TR, diagonising the fault, repair/replacement of unserviceable parts including carrying out minor repairs such as changing of small pieces of wires, tightening of loosen electric connections ,nuts, bolts screws, or switches, disconnecting andrefixing of LT cables etc as required to make the system functional in any time by deploying sufficient technician alongwith with helper incl necessay T & P complete all as specified and directed. Note: (a) Replacement of major items shall be measured and paid for separately under respective items.b) Number of complaints may vary day to day and shall be on required basis. Contractor shall quote their rates accordingly. (c) Breakdown comlplaintsshall be collectedfrom complaint cell or by telephonically from duty staff / JE E/M / Engr-in-Charge.(d) In case of failure on the part of contractor for attending any breakdown within 4 hours a penalty shall be imposed @ Rs.2000/- per complaints per day and recovered from his dues.
36Taking down the old discharge/suction/oil pressure sensor and Supply and fix new discharge pressure sensor testing and commissioning 0-5 PSI 37.5 TR compresor
37M&L for disconnecting electric motor 7.5HPand transporting to workshop, dismantling the same and taking out rotor assembly removing burnt winding coil of stator, cleaning the complete stator and rotor with carbon tetra chloride solution, rewinding the stator coil with super enameled copper conductor of proper size/gauge as per existing, inserting the new re-winded coils of stator dulyvarnishing and insulated with superior quality insulation material, replacement of old connection lead with superior quality PVC copper cable with stranded copper conductor from motor to connection plate, replacement of ball bearing, reassembling the motor, shifting to work site and connecting with the system, testing on full load complete all as specified and as directed by Engineer-in-Charge.
38All as per srl item No 36 here-in-before but of 0.335 to 0.67 HP (250 to 500 watt), single phase electric condensor fan motor.
39Dismantling the mono block pump set with motor any make, upto7.5 HP capacity servicing by cleaning lubricating and by replacing of ball bearing gland bolt, nut and washers, terminal connector, machining of shaft, gasket, gland rope, mounting bolts, reassembling, refixing with bed and testing.
40Taking down blower with motor of AHU/Package type AC any capacity, servicing by cleaning , lubricating , machining of shaft, replacement of ball bearing mounting bolts, reassembling and testing complete.
41Taking down condensor fanmotor from outdoor condensor unit of any capacity, servicing by cleaning , lubricating , machining of shaft, replacement of ball bearing mounting bolts, reassembling and testing complete.
42Replacement of Fan blade of condensor fan motor of suitable size all as specified and directed.
43Supply and fixing in replacement in replacement of water pressure gauge 4” dia, range 0 to 100 Psi complete all as specified or as directed by Engineer-in-Charge. Make:- Fiebig/Guru/york
44Supply and fixing in replacement of V- beltheavy duty complete all as specified or as directed by Engineer-in-Charge. Make:- Fenner/Dunlop or equivalent
45Supply and fixing in replacement in replacement ofthermostatexpansionvalvesuitableforACplant37.5 TRcapacitycompleteall as specified and directed. Make:- Sporlan/ Danfoss/ Renutrol
46Supply and fix in replacement Finned strip heater made of GP sheathing having terminals at one end and two holes for horizontal installation of capacity 3 KW in Air Conditioningplant installed at various locations complete all as specified or as directed.Make:- Daspass/Lazer/Usha
47Servicing/Maintenance of packaged type AC of capacity 2x17TR TR such as cleaning of fine filter with water, checking Gas and gas leakage, cleaning of condensing coil/cooling coil with water for better performance of AC plant, cleaning and greasing of condensing blower motor, AHU blower motor and booster blower motor, cleaning of condensers unit, checking tightening of all electrical connections complete all as directed.
48Servicing/Maintenance of packaged type AC of capacity 3x11 and 1x5.5 TR such as cleaning of fine filter with water, checking Gas and gas leakage, cleaning of condensing coil/cooling with water for better performance of AC plant, cleaning and greasing of condensing blower motor, AHU blower motor and booster blower motor, cleaning of condensers unit, checking tightening of all electrical connections complete all as directed.
49Servicing/Maintenance of packaged type AC of capacity 2x11 such as cleaning of fine filter with water, checking Gas and gas leakage, cleaning of condensing coil/cooling with water for better performance of AC plant, cleaning and greasing of condensing blower motor, AHU blower motor and booster blower motor, cleaning of condensers unit, checking tightening of all electrical connections complete all as directed.
50Servicing/Maintenance of packaged type AC of capacity 3x8.75 such as cleaning of fine filter with water, checking Gas and gas leakage, cleaning of condensing coil/cooling with water for better performance of AC plant, cleaning and greasing of condensing blower motor, AHU blower motor and booster blower motor, cleaning of condensers unit, checking tightening of all electrical connections complete all as directed.
51Servicing/Maintenance of VRF packaged type AC of capacity 1x12 and 2x13 TR with 10 Nos cassette indoor unitscomplete such as cleaning of fine filter with water, checking Gas and gas leakage, cleaning of condensing coil/cooling with water for better performance of AC plant, cleaning and greasing of condensing blower motor, AHU blower motor and booster blower motor, cleaning of condensers unit, checking tightening of all electrical connections complete all as directed.
52Replacement of PVC honey comb fills (drift eliminators) suitable size of central type AC plant plant all as specified and directed.
53Supply and fix Single phase preventor having voltage unbalance and phase reversal protection. Make GIC/L&T or other equivalent approved make.
54Replacement of electronic timer 240v, 50 Hz, 3-30 sec for star delta starter.Make L & Tor equivalent.
55Supply and fixing in replacement of PCB in the existing Packed unit/ Cold room AC Plant including necessary control wiring as required.Make - Softhard Automation Pvt Ltd or in equivalent.
56Supply and fixing in replacement Contactor MNX, 32 amp 3 pole, coil voltage as per existingcomplete all as specified and as directed. Make - Siemens/BCH/L&T/Schneider.
57Supply and fixing in replacement Contactor MNX, 45 amp 3 pole, coil voltage as per existingcomplete all as specified and as directed. Make - Siemens/BCH/L&T/Schneider.
58Supply and fixing in replacement Contactor MNX, 25 amp 3 pole, coil voltage as per existingcomplete all as specified and as directed. Make - Siemens/BCH/L&T/Schneider.
59Supply and fixing in replacement toggle 5 Amp switch two way brass handle as per sample.
60Supply and fixing in replacement of pressure switchLP/HP cut out M15 as per sample. Make- Danfoss/indfoss
61Servicing of cooling tower of capacity 100 TR plant by replacement of blocked/broken nozzles, Cooling tower fan and motor, cleaning descaling of complete fins including replacement of broken fin, cleaning water tray, valves, piping etc and testing complete all as per specified and directed.
62Supply and fixing in replacement over load Relay 6 to 10 Amp Make -Siemens/BCH/L&T/Schneider.
63Supply, fixing, connecting, and testing condenser fan motor of outdoor air-cooled condensers of AC plant/cold storecapacity 5.5 TR/7.5TR/11TR as per existing type and size including taking out of unserviceable motor complete all as per specified and directed.
64Supply, fixing, connecting, and testing evaporatorfan motor of cold store capacity 5.5TR/8.5 TRas per existing type and size including taking out of unserviceable motor complete all as per specified and directed.
65Supply, fixing, connecting, and testing molecular drier cum strainer on line type of size 3/8" x 3/8" make Danfoss in AC plant capacity 5.5/7.5/11/12/13/17 TR as per existing type and size including taking out of unserviceable drier complete all as per specified and directed.
66Supply and lay electricalinsulating rubber mat class ‘B’ conforming to IS 5424 (ISI marked) of 15 mm thick of size 1mx2m, suitable for HT/LT switch gearscomplete all as specified and directed. Make : Jyoti/Vardhman or equivalent.
67Supply and fixing informatory board of size 1200x900 mm frame made out of MS square tube of size 25mmx25mm, 1.6 mm thick and front side covered with coloured flex sheet duly printed with required information all asspecified and directed. Dept will provide the details of writing letter and colour of sheet and letters to board.
68M & L Check for any refrigerant leaks through flare joints, valve glandsor any of the loc in refrigerantsystem which requires leak detector device, soap solution,halide torch or electronic leak detector and arresting leakages including necessary welding, brazing works binding with teflon tape as required at site andtopping upthe gas for required suction & discharge pressurefor37.5 TR central type AC Plant. Note : Refrigerantshall be measured and paid seperately.
69Material and labour for charging Nitrogen Gas in 37.5 TR capacity centralAC plant maintaining pressure 350 Psi for checking of Gas leakage and removing water vapour choked in line, flushing out the complete system including gas leakage and detection with halide torch/ soap foam solution in system including gas welding flushing and making good the pipe line to make the system leak proof complete all as specified and as directed.
70M&L for vaccumising the plant by using vaccum pump up to (-) 30 PSIG pressure and hold the same under vaccum pressure upto 24 hours including necessary welding and brazing if required complete all as specified and directed for 37.5 TRAC plant .
71Supply and charging refrigerant Gas R-407 AC plant of various capacities includingmaintaining proper pressure after filling of Gas complete all as specified or as directed by Engineer-in-Charge.
72Supply, install, testing and commisioning ofChiller control unit with display board complete set suitable for 37.5 TRcentral type AC plant as per existing pattern and make it functional all as directed. Make : Softhard or equivalent as approved by GE.
73Supply and fixing of sign board as mentioned words (As per sample) Location and GE (West), front display made out of flex board mounted on cuboid shaped frame of required size made out of MS angle 50x50x3mm and other five sides covered with aluminium composite panel sheet 1.16 mm thick (as per sample) of size 0.15Mx 3.0Mx0.45M. The display board totally enclosed with stainless steel 304 graded pipe 25 mm bore frame and mounted on and including provision of and provision of LED Tube light fitting as required for effectiveillumination andconnecting with nearest light point by providing PVC insulated 2 core 1.5 sqmm copper cable of required lengthall as directed.
74S& F (in replacement) Vaccum control damper of existing size suitable for AC plant capacity 5.5/7.5/11/12/13/17 TR including taking out of unserviceable damper complete all as per specified and directed.
75Supply, install, testing and commisioning ofPackage type AC control unit with display board complete set suitable for 5.5/8.5/11/12/13/17 TRmultiunit AC plant as per existing pattern and make it functional all as directed.