Tender For Renovation Of Seminar Hall At Ada Hq, bangalore-Karnataka

Department Of Defence Research And Development has published Tender For Renovation Of Seminar Hall At Ada Hq. Submission Date for this Tender is 25-09-2023. Bolts Tenders in bangalore Karnataka. Bidders can get complete Tender details and download the document.




Tender Notice

39684546
Tender For Renovation Of Seminar Hall At Ada Hq
Open Tender
Indian
Karnataka
bangalore
25-09-2023

Tender Details

Tender For Renovation Of Seminar Hall At Ada Hq ; 1 Electrical Items : 2 Dismantling Aluminium / Gypsum Partitions, Doors, Windows, Fixed Glazing, False Ceiling, Flooring And Demolishing Brick Work Including Disposal Of Unserviceable Material And Stacking Of Serviceable Material With In 50 Meters Lead As Directed By Engineer-In-Charge. 3 Dismantling Of Fixed Seminar Hall Chair 4 Disposal Of Building Rubbish / Malba / Similar Unserviceable, Dismantled Or Waste Materials By Mechanical Means, Including Loading, Transporting, Unloading To Approved Municipal Dumping Ground Or As Approved By Engineer-In-Charge, Beyond 50 M Initial Lead, For All Leads Including All Lifts Involved. 5 Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia& Length ( Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately ) With Sal Wood. 6 Providing And Fixing Isi Marked Flush Door Shutters Conforming To Is : 2202 ( Part I ) Decorative Type, Core Of Block Board Construction With Frame Of 1St Class Hard Wood And Well Matched Teak 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters With 35 Mm Thick Including Isi Marked Stainless Steel Butt Hinges With Necessary Screws 7 Extra For Providing Lipping With 2Nd Class Teak Wood Battens 25 Mm Minimum Depth On All Edges Of Flush Door Shutters ( Over All Area Of Door Shutter To Be Measured ) . 8 Providing 40X5 Mm Flat Iron Hold Fast 400 Mm Long Including Fixing To Frame With 10 Mm Diameter Bolts, Nuts And Wooden Plugs And Embedding In Cement Concrete Block 300X100x150 Mm 1:3:6 Mix ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size ) . 9 Providing And Fixing Bright Finished Brass 100 Mm Mortice Latch And Lock With 6 Levers And A Pair Of Lever Handles Of Approved Quality With Necessary Screws Etc. Complete. 10 Providing And Fixing Aluminium Hanging Floor Door Stopper, Isi Marked, Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour And Shade, With Necessary Screws Etc. Complete With Twin Rubber Stopper. 11 Providing And Fixing Bright / Matt Finished Stainless Steel Handles Of Approved Quality & Make With Necessary Screws Etc All Complete Of 125 Mm. 12 Raised Platform For Seating: Providing Plywood Raised Platform Of 150Mm, 300Mm & 450Mm Height As Per Drawings Using 20Mm Thick Commercial Plywood Including Intermediate Supports, 40Mm X 40Mm Salwood Framing, Reapers To Fix Seats, Cost To Include Materials, Labour, Machinery And All Related Activities Etc., Complete ( Measurement As Per Length And Breadth Only Will Be Paid ) ( A ) 150Mm Height 13 ( B ) 300 Mm Height 14 ( C ) 450Mm Height 15 Raised Dais: Providing Plywood Raised Dias Using 20Mm Thick Commercial Plywood 450Mm Height Including Intermediate Supports Using Salwood Framing Of 40Mmx 40Mm, Cost To Include Materials, Labour, Machinery And All Related Activities Etc., Complete ( Measurement As Per Length And Breadth Only Will Be Paid ) 16 Raised Dais: Providing Plywood Raised Dias Using 20Mm Thick Commercial Plywood 450Mm Height Including Intermediate Supports Using Salwood Framing Of 40Mmx 40Mm, Cost To Include Materials, Labour, Machinery And All Related Activities Etc., Complete ( Measurement As Per Length And Breadth Only Will Be Paid ) 17 Providing And Laying In Position Below The Seating Area Imported Non Woven Carpet 6Mm Thick Of Uniproduct / Mks / Equivalent Tufted Carpeting Backed By 2Mm Pu Foam Glued To The Floor. The Edges Of The Carpet Have Be Firmly Fixed With Polished Wooden Beach / Teak Edge Beadings Including Additional For Step Risers 18 Providing And Fixing Wooden Flooring Using First Quality Burma Teak Wooden Slats Of Size 1200 ( L ) X100 ( W ) X20 ( D ) Mmnext To Each Otherfixed To 75Mm X75mmsalwood Batons Framework Placed At Right Angles Toeach Other At 600X600mm C / C With 19Mm Plywood On Top Fixed By Means Of Powder Coated Screws Over 10Mm Thick Imported Neoprine Pads Of75mmx75mmglued To The Floor & Side Of The Framework Including Filling With 50Mm Thick 1000Gsm Absorbant Wool Including Water Resistant Polish To The Teakwood Slats As Final Finish As Per The Drawings To Be Fixed Over Raised Dias Framework 19 Providing And Fixing False Ceiling At All Height Including Providing And Fixing Of Frame Work Made Of Special Sections, Power Pressed From M.S. Sheets And Galvanized With Zinc Coating Of 120 Gms / Sqm ( Both Side Inclusive ) As Per Is : 277 And Consisting Of Angle Cleats Of Size 25 Mm Wide X 1.6 Mm Thick With Flanges Of 27 Mm And 37Mm, At 1200 Mm Centre To Centre, One Flange Fixed To The Ceiling With Dash Fastener 12.5 Mm Dia X 50Mm Long With 6Mm Dia Bolts, Other Flange Of Cleat Fixed To The Angle Hangers Of 25X10x0.50 Mm Of Required Length With Nuts & Bolts Of Required Size And Other End Of Angle Hanger Fixed With Intermediate G.I. Channels 45X15x0.9 Mm Running At The Spacing Of 1200 Mm Centre To Centre, To Which The Ceiling Section 0.5 Mm Thick Bottom Wedge Of 80 Mm With Tapered Flanges Of 26 Mm Each Having Lips Of 10.5 Mm, At 450 Mm Centre To Centre, Shall Be Fixed In A Direction Perpendicular To G.I. Intermediate Channel With Connecting Clips Made Out Of 2.64 Mm Dia X 230 Mm Long G.I. Wire At Every Junction, Including Fixing Perimeter Channels 0.5 Mm Thick 27 Mm High Having Flanges Of 20 Mm And 30 Mm Long, The Perimeter Of Ceiling Fixed To Wall / Partition With The Help Of Rawl Plugs At 450 Mm Centre, With 25Mm Long Dry Wall Screws @ 230 Mm Interval, Including Fixing Of Gypsum Board To Ceiling Section And Perimeter Channel With The Help Of Dry Wall Screws Of Size 3.5 X 25 Mm At 230 Mm C / C, Including Jointing And Finishing To A Flush Finish Of Tapered And Square Edges Of The Board With Recommended Jointing Compound , Jointing Tapes , Finishing With Jointing Compound In 3 Layers Covering Upto 150 Mm On Both Sides Of Joint And Two Coats Of Primer Suitable For Board, All As Per ManufacturerS Specification And Also Including The Cost Of Making Openings For Light Fittings, Grills, Diffusers, Cutouts Made With Frame Of Perimeter Channels Suitably Fixed, All Complete As Per Drawings, Specification And Direction Of The Engineer In Charge But Excluding The Cost Of Painting With 12.5 Mm Thick Tapered Edge Gypsum Plain Board Conforming To Is: 2095- ( Part I ) :2011 ( Board With Bis Certification Marks ) 20 Supply And Installation Of Anutone Synth Stretch Srs Polyfibre Synth Pf Panels, Core-Pigmented, High-Density, Of Size As Per Requirement 25Mm Thk, Installed By Using Above Framework 21 Providing And Fixing In Position Wall Panelling At All Heights With Integral Densified Calcium Silicate Panels / Tiles Of Size 595 X 595Mm, Having Nrc ( Noise Reduction Coefficient ) Of 0.50 ( Minimum ) As Per Is 8225:1987, Light Reflectance Of 85% ( Minimum ) . Non Combustible As Per Bs:476 ( Part-4 ) , Fire Performance As Per Bs:476 ( Part 6 &7 ) , Humidity Resistance Of 100%, Thermal Conductivity <0.043 W / M K As Per Astm 518:1991, Comprising Of A Frame Made From Especially Fabricated Galvanised Mild Steel Sheet 0.50 Mm Thick Pressed Section ( Galvanizing @120 Grams Per Sqm Including Both Sides ) I.E.Vertical Studs Of Size 48 X 34 X 36 Mm Are Placed At 600Mm Center To Center In A Floor And Ceiling Channel Section Of Size 50 X 32M Fixed To The Floor And Soffit At 600Mm Centers Using 12Mm Dia, 50Mm Long Wedge Type Expanded Zinc Alloy Dash Fastner With 10Mm Bolt. This Same Channel Is Then To Be Fixed In Horiziontal Direction At 600Mm Center To Center So As To Form A Grid Of 600Mm X 600Mm. Glasswool Of 50Mm Thickness Is Then To Be Inserted In The Slots And Finally Calcium Silicate Non Combustible Panels / Tiles Are To Be Screw Fixed With Self Tapping Pan Head Nickel Coated Mild Steel Screws Of Size 13 X 3.2Mm On To This Grid Leaving An Even Groove Of 1 Mm Between The Panels. The Joints Between The Panels Are To Be Duly Jointedand Finished Using Recommended Jointing Calcium Silicate Based Compound And Fiber Joint Taperoll50mm Wide ( 90 Metre ) Roll And Two Coats Of Primer Suitable For Panelling As Per ManufacturerS Specification As Per Direction Of Engineer-In-Charge All Complete.Supply And Installation Of Anutone Slim, Polyfibre Panels, Core-Pigmented, High-Density, Synth Pf Rigid Panels Of Size1200x2400x9mmthk, Volumedensity220kg / M3, Weight 2Kg / M2adhered On Anutonestrand2 Primer, Square Edge Magnesite Bonded Pinewood Fibre Core Tiles Of Size 600X1200x15mm, Volume Density 400Kgs / M3, Weight 6Kg / M2installed By Using Above Framework 22 Providing And Fixing Anutone Salon Slats Plus 16Mm Wall Tiles Made Of Wood Fibre Cement Composites Covered With Acoustically Transparent Absorptive Microfibers On The Front Side With Anoption Of Colours As Per The Choice Of The Architect / Person In Charge Of Size 128X2430 Mm With Absorption Upto 0.75 Nrc To Be Installed Using Anutone / Himalayan Acoustics / Equivalant H Profile Fixed On G.Istuds Of 2400Mmx50mm Web&Flanges Of 15& 50Mm Fully Knurled To Give High Strength, Hot Dipped Galvanized Steel With 120Gsm Zinc Coating Specially Designed For Acoustic Vibration Management With A Backing Of Absorbant Wool Of 50Mm Thick And 1000 Gsm. The Above Work Has To Be Done As Per The Engineer-In-Charge’S Instructions And Drawings 23 Providing And Fixing Of Stage Back Wall Using Approximately 100 ( W ) X20 ( T ) Mm First Quality Melamine Polished Burma Teak Wooden Slats Fixed To50x50mm Salwood Framework At 600Mm C / Cincluding Backing Of 50Mmthick 1000 Gsm Absorbant Wool As Per The Design And Drawings 24 Providing And Fixing In Position Polyester Blend Sun Screen Full Blackout Fabric Roller Blinds With Remote Control 25 Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess / In Columns And Beams Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. ( A ) 20Mm 26 ( B ) 25Mm 27 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. ( A ) 3X2.5 Sqmm 28 ( B ) 3X4.0 Sqmm 29 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point Of Group C With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required.Note:The Scope Of The Work Includes Supplying Of Conduit Of Required Dia , Frls Pvc Ins Copper Wires Of 1.5 Sqmm , Modular Box Of Required Size, Modular Cover Plate, &Modular Switch 30 Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. ( A ) 5 / 6 Amps Switch 31 ( B ) 15 / 16 Amp Switch 32 ( C ) 3 Pin 5 / 6 Amp Socket Outlet 33 ( D ) 6 Pin 15 / 16 Amp Socket Outlet 34 ( E ) Bell Push 35 Supplying And Fixing Call Bell / Buzzer Suitable For Single Phase, 230Volts Complete As Required 36 Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required. ( A ) 1 Or 2 Module ( 75Mm X 75Mm ) 37 ( B ) 3 Module ( 100Mm X 75Mm ) 38 ( C ) 4 Module ( 125Mmx75mm ) 39 ( D ) 6 Module ( 200Mmx75mm ) 40 ( E ) 8 Module ( 125Mmx125mm ) 41 ( F ) 12 Module ( 200Mmx150mm ) 42 Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate & Switch Box Excluding Modular Plate As Required 43 Installation, Testing And Commissioning Of Pre-Wired, Fluorescent Fitting / Compact Fluorescent Fitting / Led Fittings And Of All Types, Complete With All Accessories And Tube / Lamp Etc. Directly On Ceiling / Wall, Including Connections With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable And Earthing Etc.As Required. 44 Supplying And Drawing Of Utp 4 Pair Cat 6 Lan Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. ( A ) 1 Run Of Cable 45 ( B ) 2 Run Of Cable 46 Supplying And Installing Following Size Of Perforated Painted With Powder Coating M.S. Cable Trays With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling / Surface Mount With M.S. Suspenders Including Bolts & Nuts, Painting Suspenders Etc As Required. ( A ) 100 Mm Width X 50 Mm Depth X 1.6 Mm Thickness 47 Supplying And Installing Following Size Of Perforated Painted With Powder Coating M.S. Cable Trays Bends With Perforation Not More Than 17.5%, , Joined With Connectors, Suspended From The Ceiling With M.S. Suspenders Including Bolts & Nuts, Painting Suspenders Etc As Required. ( A ) 100 Mm Width X 50 Mm Depth X 1.6 Mm Thickness 48 Supplying And Installing Following Size Of Perforated Painted With Powder Coating M.S. Cable Trays Tee With Perforation Not More Than 17.5%, Joined With Connectors, Suspended From The Ceiling With M.S. Suspenders Including Bolts & Nuts, Paintingsuspendersetc As Required. ( A ) 100 Mm Width X 50 Mm Depth X 1.6 Mm Thickness 49 Supplying, Installation, Testing & Commissioning Of Manual Call Boxes Of Ms Construction In Surface / Recess With Stainless Steel Chain & Hammer Assembly Complete With Glass And Push Button Etc. As Required. 50 Supplying, Installation, Testing & Commissioning Fire Alarm Sounder With Facility To Make Announcement, Mounted In M.S. Box ( 16 Swg ) With Hinged Cover Plate & Suitable For Operation With Amplifier I / C Line Matching Transformer Etc. Complete As Required. 51 Supplying, Installation, Testing & Commissioning Of Smoke Detector With Builtin Led And Mounting Base Complete With All Connections Etc. As Required. 52 Supplying, Installation, Testing & Commissioning Response Indicator On Surface / Recess Ms Box Having Two Leds Metallic Cover Complete With All Connections Etc. As Required. 53 Supplying & Laying Of 2X1.5 Sqmm Fire Alarm Armoured Cable, 600 / 1000V Rated With Annealed Copper Conductor Having Xlpe Insulation, Steel Wire Armouring & Frls Outer Sheath Complete As Required. 54 Wiring For 2 Lights Controlled By One No 6A Switch With 2.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Pvc Conduit, And Earthing The Point With 2.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. 55 Wiring For 3 Lights Controlled By One No 6A Switch With 2.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Pvc Conduit, And Earthing The Point With 2.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. 56 Wiring For 4 Lights Controlled By One No 6A Switch With 2.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Pvc Conduit, And Earthing The Point With 2.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. 57 Wiring For 5 Lights Controlled By One No 6A Switch With 2.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Pvc Conduit, And Earthing The Point With 2.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. 58 Supply Of Led Round Recess Mount Down Lighter With 25W System Wattage. Housing Shall Be With Powder Coated Pressure Die Cast Aluminium Alloy With Corrosion Resistant Polyester Powder Coat & With Extended Heat Sink. Diffuser / Cover Made Of Lexan Plastic Material. Rated Life Shall Be L70 @ 50000Hrs. Which Shall Has Inbuilt Electrical Protection Like Over / Under Voltage, Short Circuit, Over Load, Open Circuit & Miswiring. Driver Is On Constant Current Driver Output Driver @ 0.6A With Pf >0.9 With Line Voltage @ 220-240V @ 50 / 60Hz, Driverefficency>85%&Thd<15%.Led Efficeiency>130Lm / Wat1w & Fixture Efficiency > 100Lm / W With Cri >75 With Injection Moulded Polycarbonate Lens. Similar To Havells Endurahodlr25wled857mod 59 Supply Of Decorative Wall Light Of Led With 9W System Wattage. Gold Finish Fixture With Cognac Hammered Glass Diffuser. Rated Life Shall Be L70 @ 50000Hrs. Which Shall Has Inbuilt Electrical Protection Like Over / Under Voltage, Short Circuit, Over Load, Open Circuit & Miswiring. Driver Is On Constant Current Driver Output Driver @ 0.6A With Pf >0.9 With Line Voltage @ 220-240V @ 50 / 60Hz, Driverefficency>85%&Thd<15%.Led Efficeiency>130Lm / Wat1w & Fixture Efficiency > 100Lm / W With Cri >75 With Injection Moulded Polycarbonate Lens. Similartohavellsfloretinewl1lse27 Cgnlhfoajd1tz1a060 60 Supply Of Flexible Led Strip With Optimum Brightness And Uniformity Of Light For Perfection For Cove Lighting. Rated Life Shall Be L70 @ 50000Hrs. Which Shall Has Inbuilt Electrical Protection Like Over / Under Voltage, Short Circuit, Over Load, Open Circuit & Miswiring. Driver Is On Constant Current Driver Output Driver @ 0.6A With Pf >0.9 With Line Voltage @ 220-240V @ 50 / 60Hz, Driver Efficency > 85% & Thd < 15%. Led Efficeiency > 130 Lm / W At 1W & Fixture Efficiency > 100Lm / W With Cri >75 With Injection Moulded Polycarbonate Lens. Similar To Havells Led Flexistrip5mip2024v / 2A Led865mod V1 Or Equivalent Fitting. 61 Supplying And Fixing Rj-11 Telephone Modular Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. All Necessary Connections To The Existing Lines Need To Be Done Based On Site Conditions. 62 Supplying And Fixing Rj-45 Data Modular Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.All Necessary Connections To The Existing Lines Need To Be Done Based On Site Conditions. 63 Supply, Installation, Testing And Commissioning Of Vrf Outdoor Units With Inverter Driven Scrollcompressor, Condensor, Fans, Controlsetc..As Per The Specifications With Necessary Refrigerant Gas And Oil Charge.The Compressor Shall Be Highly Efficient Hermatic Scroll Type And Equipped With Inverter Control Capable Of Changing The Speed In Accordance To The Cooling Load Equipment.Upto 10 Different Type And Capacity Indoor-Units Can Be Connected To One Refrigerant Circuit And Controlled Induvidually.Compressor Shall Be Equipped With Inverter Controller, And Capable Of Changing The Rotating Speed To Follow Variations In Cooling Load.The Outdoor Unit Shall Be A Factory Assembled Unit Housed In A Sturdy Weather Proof Casing Constructed From Rust-Proofed Mild Panels Coated With A Baked Enamel Finish.The Noise Level Shall Not Be More Than 55 Db ( A ) At Normal Operation Measured Horizontally 1M Away And 1.5M Above Ground.The Outdoor Shall Have Multi-Step Of Capacity Control To Meet Load Fluctuation And Indoor Unit Induvidual Control.24 Hp ( Top Discharge ) Make:Bluestarnote: This Work Includes Dismantling Existing Ac And Closing Of The Duct Complete As Directed By Engineer In Charge. 64 Supply, Installation, Testing And Commissining Of 4 Way Large Cassette Type Unit, Indoor Unit With Compact Cooling Coil, Electronic Expansion Valve, Three Speed Fan Motors, Dynamically Balanced Blowers, Provision For Fresh Air Intake, Synthetic Washable Media Filter Including Insulation And Suitable For Operation On Single / Three Phase Ac Supply & Remote Control Operation Etc As Required. Make: Bluestar3.2 Tr 65 Supply And Fixing Of Cordless Remote Controller 66 Supply, Installation, Testing And Commissioning Of Variable Refrigerant Flow Distribution Refnets In The Suction& Liquid Lines For Various Sizes Of Copper Refrigerant Piping Including Insulation Etc. Complete As Required. 67 Supply, Installation, Testing And Commissioning Ofinterconnecting Refrigerant Copper Pipe Work With Elastomeric Nitrile Rubber / Closed Cell Expanded Polythene Tubular Insulation Between Each Set Of Indoor & Outdoor Units As Per Specifications, All The Pipe Should Be Properlysupported By Threaded Rod With Slotted Channel For Suction And Discharge Lane 68 Supplying And Drawing Flexible Multicore Cable Manufactured With Electrolytic Grade Flexible Copper With Low Conductor Confirming To Table 3 Class 5 Of Is:8130-1984 And ( Virgin ) Pvc Insulation Suitable For Working Voltage Upto 1100Volts As Per Is-694:1990 & Confirming To Gtp Of Group-A ( A ) Copper Flexible Cabling For Control Cabling 3Core X 2.5 Sqmm Between Indoor Unit And Plug Top And Ac Distibution To 3 Pin Socket 69 ( B ) Copper Flexible Cabling For Control Cabling 2Core X 0.75 Sqmm Shielded Between Indoor Unit And Out Door Unit. 70 ( C ) Copper Flexible Cabling For Control Cabling4core X 16 Sq.Mm Power Cabling From Power Source Mcb To Out Door Unit. 71 Supply & Fixing Ofpvc Pipe With 6 Mm Thick Nitrile Rubber Insulation For Condensate Water From The Ac Units. ( A ) 25Mm 72 ( B ) 32 Mm 73 ( C ) Supply & Charging Of Refrigerant R410a 74 Supply And Fixing Of M.S Stand For Outdoor Units Duly Painted By Redoxide And 2 Rounds Of Enamel Coating Of Black Paint On It.For Fixing The Stands To Place Condensor / Condensing Units. 75 Lifting & Shifting Charges 76 Providing And Fixing To Base Seating With Base Frame 75Dia 10Swg Tubular Mild Steel Powder Coated After Seven Step Pre Treatment Process, Including Arm Rest Supports In 8Mm Ms Sheet Laser Cut And Powder Coated After Seven Step Pre Treatment Process, Arm Rest Made Of 25Mm Solid Termite Proof Rubber Wood Finished With Three Coats Of Matte Melamine, Seat Frame Of 19Mm Dia 16Swg Tubular Mild Steel, 3Mm Ms Flats Galvanized With Internal Coil Spring For Cushioning With Seat Cushion In High Density Polyurethane Foam Upholstered With Approved Polyester Fabric. Unit Is Mounted Onto To The Floor Using 10Mm Mild Steel Anchoring Plates And M10 Heavy Duty Anchor Bolts. With Gravity Tip Upmovement ( 550 X 590Mm ) 77 Providing And Fixing In Position Upholstered Twin Seater Sofa Sets Using Solid Rubberwood Which Is In Either Stained Walnut Or Natural And Finished With Melaminelaquer Andthe Cushions Are Removableand Upholstered In A Variety Of Fabrics And Colours. 78 Providing Laminated Mdf 18Mm Podium With Edge Banding Cladding By 18Mm Lumber Board With Drawer Unit, Prelaminated Mdf Mounted On Castor 3 Wheels As Per Approved By The Client / Architect As Per The Drawing / As Required. Cost To Include Labour, Transportation , Loading And Unloading Etc., All Necessary Wire Manager Cutouts And Cable Race Ways Is Included.

Key Value

Document Fees
Refer document
EMD
INR 109342.0 /-
Tender Value
INR 54.67 Lakhs /-

BOQ Items

Name of Work: RENOVATION OF SEMINAR HALL AT ADA HQ
Sl. No. Item Description
1Electrical Items :
2Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing, false ceiling, flooring and Demolishing Brick work including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge.
3Dismantling of fixed seminar hall chair
4Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
5Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia& length (hold fast lugs or dash fastener shall be paid for separately) with Sal Wood.
6Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters with 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
7Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
8Providing 40x5 mm flat iron hold fast 400 mm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 300x100x150 mm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
9Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
10Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete with Twin rubber stopper.
11Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete of 125 mm.
12Raised Platform for Seating: Providing plywood raised platform of 150mm, 300mm & 450mm height as per drawings using 20mm thick Commercial Plywood including intermediate supports, 40mm x 40mm Salwood framing, reapers to fix seats, cost to include materials, labour, machinery and all related activities etc.,complete (measurement as per length and breadth only will be paid) (a) 150mm height
13(b) 300 mm height
14(c) 450mm height
15Raised Dais: Providing plywood raised dias using 20mm thick Commercial Plywood 450mm height including intermediate supports using Salwood framing of 40mmx 40mm, cost to include materials, labour, machinery and all related activities etc., complete(measurement as per length and breadth only will be paid)
16Raised Dais: Providing plywood raised dias using 20mm thick Commercial Plywood 450mm height including intermediate supports using Salwood framing of 40mmx 40mm, cost to include materials, labour, machinery and all related activities etc., complete(measurement as per length and breadth only will be paid)
17Providing and laying in position below the seating area imported non woven carpet 6mm thick of Uniproduct/ MKS/ equivalent Tufted Carpeting backed by 2mm PU foam glued to the floor. The edges of the carpet have be firmly fixed with polished wooden beach/teak edge beadings including additional for step risers
18Providing and Fixing wooden flooring using First Quality Burma teak wooden slats of size 1200(L) X100(W) X20(D)mmnext to each otherfixed to 75mm X75mmsalwood batons framework placed at right angles toeach other at 600X600mm c/c with 19mm plywood on top fixed by means of powder coated screws over 10mm thick Imported Neoprine pads of75mmX75mmglued to the floor & side of the framework including filling with 50mm thick 1000GSM absorbant wool including water resistant polish to the teakwood slats as final finish as per the drawings to be fixed over RAISED DIAS FRAMEWORK
19Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/Sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks)
20Supply and installation of Anutone Synth Stretch SRS polyfibre Synth PF panels, core-pigmented, high-density, of size as per requirement 25mm thk, installed by using above framework
21Providing and fixing in position wall panelling at all heights with integral densified calcium silicate panels/tiles of size 595 x 595mm, having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity <0.043 W/m K as per ASTM 518:1991, comprising of a frame made from especially fabricated galvanised mild steel sheet 0.50 mm thick pressed section (galvanizing @120 grams per Sqm including both sides) i.e.vertical studs of size 48 x 34 x 36 mm are placed at 600mm center to center in a floor and ceiling channel section of size 50 x 32m fixed to the floor and soffit at 600mm centers using 12mm dia,50mm long wedge type expanded zinc alloy dash fastner with 10mm bolt. This same channel is then to be fixed in horiziontal direction at 600mm center to center so as to form a grid of 600mm x 600mm. Glasswool of 50mm thickness is then to be inserted in the slots and finally calcium silicate non combustible panels/tiles are to be screw fixed with self tapping pan head nickel coated mild steel screws of size 13 x 3.2mm on to this grid leaving an even groove of 1 mm between the panels. The joints between the panels are to be duly jointedand finished using recommended jointing calcium silicate based compound and fiber joint taperoll50mm wide (90 metre )roll and two coats of primer suitable for panelling as per manufacturer"s specification as per direction of Engineer-in-Charge all complete. Supply and installation of Anutone Slim, polyfibre panels, core-pigmented, high-density, Synth PF rigid panels of size1200x2400x9mmthk,volumedensity220kg/m3,weight 2kg/m2adhered on AnutoneStrand2 primer,square edge Magnesite bonded pinewood fibre core tiles of size 600x1200x15mm, volume density 400kgs/m3, weight 6kg/m2installed by using above framework
22Providing and fixing Anutone Salon Slats Plus 16mm wall tiles made of Wood Fibre cement composites covered with Acoustically Transparent Absorptive microfibers on the front side with anoption of colours as per the choice of the Architect/ person in charge of size 128x2430 mm with absorption upto 0.75 NRC to be installed using Anutone/Himalayan Acoustics/equivalant H profile fixed on G.Istuds of 2400mmX50mm web&flanges of 15& 50mm fully knurled to give high strength, hot dipped galvanized steel with 120GSM zinc coating specially designed for Acoustic vibration management with a backing of absorbant wool of 50mm thick and 1000 GSM. The above work has to be done as per the engineer-in-charge’s instructions and drawings
23Providing and Fixing of Stage back wall using approximately 100(W)X20(T)mm First Quality melamine polished Burma teak wooden slats fixed to50X50mm Salwood framework at 600mm c/cincluding backing of 50mmthick 1000 GSM absorbant wool as per the design and drawings
24Providing and fixing in position polyester blend sun screen full blackout fabric roller blinds with remote control
25Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess / in columns and beams including cutting the wall and making good the same in case of recessed conduit as required. (a) 20mm
26(b) 25mm
27Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. (a) 3x2.5 Sqmm
28(b) 3x4.0 Sqmm
29Wiring for light point/ fan point/ exhaust fan point/ call bell point of group "C" with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. NOTE:The Scope of the Work includes supplying of conduit of required dia , FRLS PVC Ins Copper Wires of 1.5 sqmm , modular box of required size, modular cover plate,&modular switch
30Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (a) 5/6 amps switch
31(b) 15/16 amp switch
32(c)3 pin 5/6 amp socket outlet
33(d) 6 pin 15/16 amp socket outlet
34(e) Bell Push
35Supplying and fixing call bell/ buzzer suitable for single phase, 230Volts complete as required
36Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. (a) 1 or 2 Module (75mm x 75mm)
37(b) 3 Module (100mm x 75mm)
38(c ) 4 Module (125mmX75mm)
39(d) 6 Module (200mmX75mm)
40(e) 8 Module (125mmX125mm)
41(f) 12 Module (200mmX150mm)
42Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required
43Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting/ LED Fittings and of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc.as required.
44Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. (a) 1 Run of Cable
45(b) 2 Run of Cable
46Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling/ surface mount with M.S. suspenders including bolts & nuts, painting suspenders etc as required. (a) 100 mm width X 50 mm depth X 1.6 mm thickness
47Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. (a) 100 mm width X 50 mm depth X 1.6 mm thickness
48Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, paintingsuspendersetc as required.(a) 100 mm width X 50 mm depth X 1.6 mm thickness
49Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.
50Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.
51Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required.
52Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required.
53Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
54Wiring for 2 Lights controlled by One No 6A Switch with 2.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 2.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
55Wiring for 3 Lights controlled by One No 6A Switch with 2.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 2.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
56Wiring for 4 Lights controlled by One No 6A Switch with 2.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 2.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
57Wiring for 5 Lights controlled by One No 6A Switch with 2.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 2.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
58Supply of LED round recess mount down lighter with 25W system wattage. Housing shall be with powder coated pressure die cast aluminium alloy with corrosion resistant polyester powder coat & with extended heat sink. Diffuser/cover made of Lexan plastic material. Rated life shall be L70 @ 50000Hrs. which shall has inbuilt electrical protection like over/under voltage, short circuit, over load, open circuit & miswiring. Driver is on constant current driver output driver @ 0.6A with PF >0.9 with line voltage @ 220-240V @ 50/60Hz,driverefficency>85%&THD<15%.LED Efficeiency>130lm/Wat1W & fixture efficiency > 100Lm/W with CRI >75 with injection moulded polycarbonate lens. Similar to Havells ENDURAHODLR25WLED857MOD
59Supply of Decorative Wall light of LED with 9W system wattage. Gold finish fixture with cognac hammered glass diffuser. Rated life shall be L70 @ 50000Hrs. which shall has inbuilt electrical protection like over/under voltage, short circuit, over load, open circuit & miswiring. Driver is on constant current driver output driver @ 0.6A with PF >0.9 with line voltage @ 220-240V @ 50/60Hz,driverefficency>85%&THD<15%.LED Efficeiency>130lm/Wat1W & fixture efficiency > 100Lm/W with CRI >75 with injection moulded polycarbonate lens. SimilartoHavellsFLORETINEWL1LSE27 CGNLHFOAJD1TZ1A060
60Supply of Flexible LED strip with optimum brightness and uniformity of light for perfection for cove lighting. Rated life shall be L70 @ 50000Hrs. which shall has inbuilt electrical protection like over/under voltage, short circuit, over load, open circuit & miswiring. Driver is on constant current driver output driver @ 0.6A with PF >0.9 with line voltage @ 220-240V @ 50/60Hz, driver efficency > 85% & THD < 15%. LED Efficeiency > 130 lm/W at 1W & fixture efficiency > 100Lm/W with CRI >75 with injection moulded polycarbonate lens. Similar to Havells LED FLEXISTRIP5MIP2024V/2A LED865MOD V1 or Equivalent fitting.
61Supplying and fixing RJ-11 Telephone modular socket on the existing modular plate & switch box including connections but excluding modular plate etc. as plate & switch box including connections but excluding modular plate etc. as required. All necessary connections to the existing lines need to be done based on site conditions.
62Supplying and fixing RJ-45 DATA modular socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.All necessary connections to the existing lines need to be done based on site conditions.
63Supply,Installation,testing and commissioning of VRF outdoor units with inverter driven scrollcompressor, Condensor, fans,controlsetc..as per the specifications with necessary refrigerant gas and oil charge.The compressor shall be highly efficient hermatic scroll type and equipped with inverter control capable of changing the speed in accordance to the cooling load equipment. Upto 10 different type and capacity indoor-units can be connected to one refrigerant circuit and controlled induvidually. Compressor shall be equipped with inverter controller,and capable of changing the rotating speed to follow variations in cooling load. The outdoor unit shall be a factory assembled unit housed in a sturdy weather proof casing constructed from rust-proofed mild panels coated with a baked enamel finish. The noise level shall not be more than 55 dB(A) at normal operation measured horizontally 1m away and 1.5m above ground. The outdoor shall have multi-step of capacity control to meet load fluctuation and indoor unit induvidual control. 24 HP (Top Discharge) MAKE:BLUESTAR Note: This work includes Dismantling existing AC and closing of the duct complete as directed by engineer in charge.
64Supply, Installation, Testing and commissining of 4 way Large Cassette type Unit,Indoor Unit with compact cooling coil, electronic expansion valve, three speed fan motors, dynamically balanced blowers, provision for Fresh Air Intake, synthetic washable media filter including insulation and suitable for operation on single/three phase AC supply & remote control operation etc as required. Make: Bluestar 3.2 TR
65Supply and fixing of cordless remote controller
66Supply, Installation, Testing and commissioning of Variable refrigerant flow distribution Refnets in the suction& liquid lines for various sizes of copper refrigerant piping including insulation etc. complete as required.
67Supply, installation, testing and commissioning ofinterconnecting refrigerant Copper pipe work with elastomeric nitrile rubber/closed cell expanded polythene tubular insulation between each set of indoor & outdoor units as per specifications, all the pipe should be properlySupported by Threaded rod with slotted channel for suction and discharge lane
68Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to table 3 class 5 of IS:8130-1984 and (Virgin) PVC insulation suitable for working voltage upto 1100Volts as per IS-694:1990 & confirming to GTP of GROUP-A (a) Copper Flexible Cabling for Control Cabling 3Core x 2.5 sqmm between Indoor unit and plug top and AC distibution to 3 pin socket
69(b) Copper Flexible Cabling for Control Cabling 2Core x 0.75 sqmm shielded between Indoor unit and Out door unit.
70(c )Copper Flexible Cabling for Control Cabling4Core x 16 Sq.mm Power Cabling From Power Source MCB To Out door Unit.
71Supply & Fixing ofPVC Pipe with 6 mm thick nitrile rubber insulation for condensate water from the AC Units. (a) 25mm
72(b) 32 mm
73( c) Supply & charging of refrigerant R410A
74Supply and Fixing of M.S Stand for Outdoor units duly painted by redoxide and 2 rounds of enamel coating of black paint on it.for fixing the stands to place condensor/condensing units.
75Lifting & Shifting Charges
76Providing and fixing to base seating with base frame 75dia 10swg Tubular Mild steel powder coated after seven step pre treatment process, including arm rest supports in 8mm MS sheet laser cut and powder coated after seven step pre treatment process, arm rest made of 25mm solid termite proof rubber wood finished with three coats of matte melamine, Seat frame of 19mm dia 16swg tubular mild steel, 3mm MS flats galvanized with Internal coil spring for cushioning with seat cushion in high density polyurethane foam upholstered with approved polyester fabric. Unit is mounted onto to the floor using 10mm mild steel anchoring plates and M10 heavy duty anchor bolts. with gravity tip upmovement (550 x 590mm)
77Providing and fixing in position upholstered twin seater sofa sets using solid rubberwood which is in either stained walnut or natural and finished with melaminelaquer andthe cushions are removableand upholstered in a variety of fabrics and colours.
78Providing laminated MDF 18mm Podium with edge banding cladding by 18mm lumber board with drawer unit, prelaminated MDF mounted on castor 3" wheels as per approved by the client/architect as per the drawing/as required. Cost to include labour, transportation , loading and unloading etc., All necessary wire manager cutouts and cable race ways is included.