Replacement Of Existing 33 Kv Acsr Dog Conductor With 33 Kv Aaac Al-59 , 241 Sq Mm Covered Conductor At Different Work Site From Kalibar To Bhakra Nadi Under Edd Ramnagar, haldwani-Uttarakhand

Uttarakhand Power Corporation Limited-UPCL has published Replacement Of Existing 33 Kv Acsr Dog Conductor With 33 Kv Aaac Al-59 , 241 Sq Mm Covered Conductor At Different Work Site From Kalibar To Bhakra Nadi Under Edd Ramnagar. Submission Date for this Tender is 19-09-2023. Conductor Tenders in haldwani Uttarakhand. Bidders can get complete Tender details and download the document.




Tender Notice

39637693
Replacement Of Existing 33 Kv Acsr Dog Conductor With 33 Kv Aaac Al-59 , 241 Sq Mm Covered Conductor At Different Work Site From Kalibar To Bhakra Nadi Under Edd Ramnagar
Open Tender
Indian
Uttarakhand
haldwani
19-09-2023

Tender Details

Replacement Of Existing 33 Kv Acsr Dog Conductor With 33 Kv Aaac Al-59 , 241 Sq Mm Covered Conductor At Different Work Site From Kalibar To Bhakra Nadi Under Edd Ramnagar

Key Value

Document Fees
INR 11800 /-
EMD
INR 494000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Replacement of existing 33 KV ACSR Dog conductor with 33 KV AAAC AL-59 , 241 sq mm Covered Conductor at Different work site from Kalibar to Bhakra Nadi under EDD Ramnagar
Sl. No. Item Description
1A Decentralized Material
233 KVAAAC AL-59 , 241 sq mm Covered Conductor (As per EN- 50397-1:2006) .The conductor shall be stranded, round,non compacted and water tight. Non Compacted conductor shall comply with all the requirement of EN 50397-1-2006. The stranded conductor shall be longitudinally water blocked by means of a water blocking material.Thesemi conducting screen, inner insulation and outer insulation should be extruded in one step. The outer covering insulation shall be UV-stabilized, tracking resistant black XLPE.
3MVCC Accessories (As per EN - 50397-2) as below:
433 KV Tension Clamp with bail & IPC
533 KV Cable Ties for Pin Insulator.
633 KV IPC for covered to coveredconnections
733 KV IPC for covered to Bare connections
833 KV Mid Span Jointing Kit
9IPC with Aluminium Bail for earthing
1033 KV Disc insulator for AAAC Covered Conductor
1133 KV Pin Insulator 120 KN
12PP and Clamp for SP-55 with N&B
13Stay Clamp for SP-55 with N&B
14Bracing Clamp Top for SP 55 with N&B
15Bracing Clamp Bottom For SP 55 With N&B
16B Labour Charge: Cartage of following material from ESC to Road site of work dist. Apprx. 160 km Loading/unloading comp.
17ST pole SP-55
18Small Material
19Head load cartage of following material from road site to work site dist. Apprx. 0-2 km Loading/unloading comp.
20(a) ST pole SP-55
21(b) Small Material
22Fabrication of steel by cutting and drilling properly
23Digging of pit for Pole as per upcl norms.(0.9*0.6*1/6 Pole Length)*Pole
24Erection of new 33 KV D/P Structure as per upcl norms
25Grouting of Pole as per norms (0.45*0.45*1/9 of pole length)*Pole
26Digging of pit for stay as per upcl norms (0.6*0.6*1.20 Mtr)
27Grouting of Stay as per norms (0.6*0.6*0.3)*stay
28Providing and Fixing of new 33 KV stay as per upcl norms
29Fixing , tightening and Nozzeling of StayWith pole and Stay rod on required Tension as per per drawing
30Removing of old conductor with opening of existing jumpering and making of bundle.
31Laying, spreading, stringing, sagging of 33 KV line in 3 Phase of the following wire as phase wire including proper sagging with binding and jumpering as per user manual and sagging comp. work done(Inclusive of cartage and head load cartage at work site).Rollers of the appropriate diameter and quantity have to to be provided for installation.The rollers shall have a smooth clean surface, no sharp edges and shall rotate easily.To prevent the covering from damage any abrasive contact with soil or stone is not permitted. Abrasive contact of the covering with branches or similar shall be avoided.Covered conductor shall be pulled by using appropriate pulling devices ensuring that the pulling force is distributed to the conductor.Recommendationsgiven in EN-50397-3 should be followed for storage, transport and installation of covered conductor.
3233 KVAAAC AL-59 , 241 sq mm Covered Conductor
33Excavation of earth and erection of 33 KV single support with CC Comp.
34Fixing of MVCC Accessories
3533 KV Tension Clamp with bail & IPC
3633 KV Cable Ties for Pin Insulator.
3733 KV IPC for covered to coveredconnections
3833 KV IPC for covered to Bare connections
3933 KV Mid Span Jointing Kit
40IPC with Aluminium Bail for earthing
4133 KV Disc insulator for AAAC Covered Conductor
4233 KV Pin Insulator
43Chemical Earthing on pole structure (Existing/New)
44Providing and fixing of 33 KV Termination Kit
45Providing and fixing Anti climbing device for 33 KV new structures
46Plinth for 33 KV D/P.
47Painting of Poles SP 55
48Back cartage of dismantled material from work site to work road side.Average distance 2 Km
49Line material
50Back cartage of dismantled material from work road side to Store centre Rishikesh.Average distance 160 Km
51Line material
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail