Dakshinanchal Vidyut Vitran Nigam Limited-DVVNL has published Work Of 11 Kv / Lt Line/ Vcb/ Transformer Construction/Installation In Edsd – Ii & Iiinagla Patti & Nadrai In The Edd,Kasganj Under The Juridiction Of Edc, Kasganj On Semi Turn-Key Basis.. Submission Date for this Tender is 20-09-2023. Screws Tenders in kasganj Uttar Pradesh. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 19-Sep-2023 | Date Extension | Date | 20-09-2023 |
Sl. No. | Item Description |
1 | Supply Of Material |
2 | Stone Pad |
3 | PCC Pole 9 Mtr. Long |
4 | F Bracket |
5 | Stay Rod Set Complete |
6 | Earthing Rod Set Complete |
7 | 33 KVEarth Wire (10 mm) |
8 | Guarding/ G.I. Wire 8 S.W.G. |
9 | G.I Wire 10 S.W.G. |
10 | Holding / Stay Clamp |
11 | F Clamp for PCC/ STP |
12 | Danger Board with clamp |
13 | GI Pipe "6" Dia |
14 | Cabel Jointing Kit 33 KV 3x300 sqmm O/D |
15 | Cabel Jointing Kit 33 KV 3x300 sqmm I/D |
16 | T off Channel |
17 | Battery Charger 24 volt |
18 | Battery Set 24 volt |
19 | M.S. Guarding Angel |
20 | Cabel Jointing Kit 11 KV 3x120 sqmm OD |
21 | Cabel Jointing Kit 11 KV 3x185 sqmm O/D |
22 | 33 KV Fuse Set |
23 | 160 mm O/D PN 4 PE 80 Grade UVStblised HDPE Pipe |
24 | 300 sqmm. XLPE Cabel |
25 | Number of Plate |
26 | PVC Joint Connector |
27 | Barbed Wire G.I. |
28 | Nut & Bolt off size |
29 | I Hook |
30 | Dead & Clamp |
31 | 33 KV VCB with Single T/F control pannel CT 200/100/1A with structure (I) 33 Kv VCB (ii) control pannel 1/C for 33 kv single T/F (iii) CT 200/100/1-1A (iv) steel structure |
32 | Erection of Material |
33 | Erection of 33 KV VCB with Single T/F control pannel & CT 200/100/1A with structure (I- 33 KC VCB, II- control pannel 1/C for 33 kv single T/F,III- CT 200/100/1-1A &IV-steel structure) |
34 | Installation & Fixing Battery Charger 24 volt & Battery Set 24 volt |
35 | Installation of new Plinthin all respect of 250 KVAT/F 11/0.4 KV New |
36 | Carriage from Store & Installation of 250 KVA T/F 11/0.4 KVA New at site. |
37 | Earthing of 100/250/400 KVAT/F Body & Neutral in all respect. |
38 | Laying of 160 mm O/D PN 4 PE 80 Grade UVStblised HDPE Pipe |
39 | Erection of 11 KV VCB incoming CTR 600/300/10A |
40 | Erection & Installation of 11 KV VCB outgoing CTR 200/100/5A , 350 MVA |
41 | Installation of 11 kv/ 33/11 KV jointing kit indoor /outdoors 3x120/185/ 3x300 Sq mm. |
42 | Laying & Fixing of 11 KV XLPE Cable 3x185 sqmm. |
43 | Laying & Fixing of 11/33 KV XLPE Cable 3x300 sqmm. |
44 | Erection of single support including complete H.T/L.T fittings S.T. Pole 11 Mtr. SP-55 including Earthing, Grouting & Muffing of pole. |
45 | Erection of single support including complete H.T/L.T fittings PCC Pole 8.5 Mtrincluding Earthing, Grouting & Muffing of pole. |
46 | Erection of single support including complete H.T/L.T fittings PCC Pole 9 Mtrincluding Earthing, Grouting & Muffing of pole. |
47 | Fixing Of Danger board |
48 | Erection of stay set complete including the work of nuzzling etc. |
49 | Laying sagging stringing, binding and jumpering ACSR Weasel conductor |
50 | Laying sagging stringing, binding and jumpering ACSR Dog conductor |
51 | Laying & Fixing of LT ABC Cabel 3x120 sqmm. |
52 | Fixing of Barbed Wire G.I. |
53 | Sagging, Fixing of G.I. Wire 10SWG/ 8 SWG/6 SWG |
54 | Earthing complete of 11 KV VCB pannel |
55 | Installation of 33 KV Fuse Set |
56 | Installation / Erection of fancing in all respect of 250 KVAT/F 11/0.4 KV New |
57 | Connecting HT Cabel connection from 33 kv side & 11 KV side of 10 MVA Power Transformer |
58 | Water level earthing of 10/ 2x5 MVA by Boring and lowering of G.I. pipe size 40 mm dia & thickness 2 mm into the ground at 20 mtr depth or upto the water level with the lower end of solid copper cone Approx 225 mm long and 750 gm in weight shall be provided and screwed in pipe as well as bringing out a continuous copper wire 6 SWG from the cone up to the ground surface where it will be bolted to the M.S. earth Strip for Transformer body & neutral connection, the earth strip will be welded to the G.I. pipe and neutral earthing support. All required material provided/ supply by the contractor own his cost. |
59 | Making of M.S. Angle Ladder type frame of Angle (75x75x8mm) & GI Strip (50x6mm) near power transformer for power cable with concreting of the same in the ground and proper clamping (50x6mm) of the same with transformer cable. |
60 | Making of M.S. Angle frame of (75x75x8mm) in L shape to connect T/F Neutral by flexible copper strip including cost of copper strip & wll be connected to newly constructed well type earthing for Power T/F Neutral as per RESPO norms. |
61 | Underground Railway Crossing Permission Fees |
62 | Charges for Dismantling Work:- Work includes dismantling from site and cartage of same materails from site/location to central store/any other place as per instruction of JE/SDO/EE concerned. |
63 | 33 KV VCB with Single T/F Contro Pannel CT 200/100/1 A with Structure |
64 | 11 KV VCB Outgoing CTR 200/100/5A |
65 | ACSR Dog/Weasel Conductor (Scrap) |
66 | 11 KV XLPE Al. Cabel 3x185 sqmm. |
67 | G.I. Wire (Scrap) |
68 | 11 KV VCB incmoing CTR 600/300/10A |
69 | 33/11 KV XLPE Cable 3x120 sqmm (4.8kg/mtr) |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail