| 1 | PART A CIVIL WORK |
| 2 | E.W In Excavation In Foundation Trenches OrDrains Including Dressing Of Sides & Ramming Of Bottoms, Lift Upto 1.50 Mtr Including Taking Out The Excavated Soil And Depositing & Refilling Of Jhiri With Watering & Ramming & Disposal Of Surplus Excavated Soil as Directed within a lead of 50 m. all kind of soil |
| 3 | P&L Cement Concrete Including Curing, Compaction Etc. Complete Using stone Aggregate 40mm Nominal SizeIn Floring & FoundationExcluding The Cost Of Shuttering Using 1 Cement:4 Sand:8 Aggregate Mix. |
| 4 | Brick work with common burnt clay F.P.S. (Non Modular) bricks of class designation 7.5 infoundation and plinth with CM 1:6 |
| 5 | Centering and shuttering with plywood or steel sheets including strutting, propping, bracing both ways and removal of formwork for foundations in basements rafts, footings, strap beams, bases of columns , etc. up to plinth level. |
| 6 | Providine And Laying In Position specified grade ofreinforcement Cement Concrete Including Curing, Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttring Upto Plinth Level In 1:1.5:3 (1 Cem. :1.5 Coar. Sand : 3 Graded Stone Aggr. 20mm Non. Size) |
| 7 | Supply & Stacking good earth at site complete including loading unloading & transporation etc. Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth , consolidatingeach deposited layer by ramming and watering including lead upto 50Mtr. and lift upto 1.5Mtr. |
| 8 | Brick work with F.P.S. bricks of class designation 75 in superstacture above plinth level upto floor five level in all shape and size in CM 1:6 |
| 9 | Brick work with F.P.S. bricks of class designation 75 in superstacture above plinth level upto floor five level in all shape and size in CM 1:4 Add extra for square or rectangular pillars Upto 45 cm length and all sides are free. |
| 10 | Centering and shuttering with plywood or steel sheets including strutting, propping, bracing both ways with wooden members andremoval of formwork for superstructure up to 4.5 mtr aboveplinth,for:Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands , coping, bed plates, anchor blocks, sills, chhajjas lintel, beam etc. |
| 11 | Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcementfor Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.M20 grade Nominal Mix / Design Mix |
| 12 | Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor three level.Cold twisted bars (IS:1786) |
| 13 | Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs 10 Cm. long embedded in cement concrete blocks 15x10x10 Cm. of 1:3:6 (1-Cement:3-coarse sand:6-graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. |
| 14 | Providing And Fixing Steel Glazed Doors Windows And Ventilator With Shutters Of Standard Rolled Steel Section Joints Mitred And Welded With Steel Lugs 13x13 Mm, 10 Cm. Long Embedded In Cement Concrete Block 15x10x10 Cm Of 1:3:6 (1 Cement:3 Course Sand:6 Graded Stone Aggregate 20 Mm Nominal Size) Or With Wooden Plugs And Screw Or Rawl Plungs And Screws With Fixing Clips Or With Bolts And Nuts As Required Including Providing Adn Fixing Of Plain Glass Panes 4 Mm Thick With Coper Glazing Clips And Special Metal Sash Putty Of Approved Make Or Metal Beading With Screws Complete Including The Cost Of Metal Beading And Other Fitting Except Necessary Hings Of Pivots Steel Handles Peg Stay Etc. As Required As Per Is:1038.Partly fixed and partly openable(fixed area not to exceed 33%) |
| 15 | P&F M.S. Sheet 1mm thick Double Leaf Door Shutter In Angle Iron Frame 35 x35 x 5mmSuitability Diagonally Braced With 25*3mm Flat Iron Above And Below Lock Rail Of Size 50 x 5mm Beading Extra Including All Fittings As Per Direction Of Chokhats But Excluding Cost Of Chowkhats.Including two coats of anti-corrosive red oxide primer paint. |
| 16 | P&F Guard Bars For Windows & Bottom Of Doors Frame. |
| 17 | Supplyingand fixing fixed wire gauge of 14 mesh x24 gauge to the metal frame of rolled section by beading 20x3mm with suitable screw at not exceeding 150 mm distance. |
| 18 | 6 mm cement plaster to ceiling of mix 1:3 (1 cement :3 corse sand) |
| 19 | Internal Plaster--Plaster On New Surface On Walls In Cement Sand Mortar 1:6 IncludingRacking Of Joint Etc. Complete Fine Finished. 12mm Thick |
| 20 | External Plaster -Plaster On New Surface On Walls In Cement Sand Mortar 1:6 IncludingRacking Of Joint Etc. Complete Fine Finished. 20 mm thick |
| 21 | Making grooves as per design in plaster 10mm to 20mm wide |
| 22 | P&L 25 mm thick Polished blue kota stone flooring Skirting laid Over 20 mm thick base of CM 1:4 & jointed with grey cement slury math the shade of slabe incld rubbing and polishing complete. Size 901 to 2000 sqcm. |
| 23 | P&L 25 mm thick Polished blue kota stone flooring Skirting laid Over 20 mm thick base of CM 1:4 & jointed with grey cement slury math the shade of slabe incld rubbing and polishing complete. Size 2000 sqcm. |
| 24 | Providing and laying cement concrete including curing, compaction etc. complete in retaining walls, return walls (any thickness) including attached pilasters, coloumns, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, plain window sills, fillets levelling course etc up to floor five level excluding the const centering and shuttering. |
| 25 | Providing and fixing 20 mm thick precast terrazo tiles of approved make, with marble chips of size upto 6mm laid over roof with neat cement slurry mixed with pigment to match the shade of the tiles, including cutting ,grinding rubbing with machinecomplete on 20 mm thick bed of cement sand mortar 1 : 4. |
| 26 | Providing batta (gola) 75mm x 75mm in cement concrete (1:2:4) including finished with cement mortar 1:3 as per standard design. |
| 27 | Making khurras 450 x 450mm with averageminimum thickness 50 mm cement concrete 1:2:4 over P.V.C. Sheet 1 Mtr. x 1 Mtr. x 40 micron finished with 12 mm cement plaster 1:3 and one coat of neat cement, rounding edges and making and finishing the out let complete. |
| 28 | Interior Finishing :-Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding:New work (two or more coats) over and including scrapping and priming coat with cement primer. |
| 29 | Exterior Finishing :- Painting exterior surface ofWallwith 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty,etc complete in all respect. including scaffolding and safety provision OnNewwork |
| 30 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on New Work |
| 31 | Green Board :-Providing and fixing wall panelling using soft wood frame of size 50x25mm @600 mm c/c in both directions duly treated with anti-termite treatment making grooves painting of grooves specification and drawing using :12 mm thick one side laminated board Practical board (Phenol bonded) |
| 32 | PART B SANITARY WORK |
| 33 | P&F rigid 110 mm dia pvc pipe class IInd (4kg./cm2) approved quality make including jointing the pipe with solvent cement rubber rim & lubricant |
| 34 | PART C ELECTRIC WORK |
| 35 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it\"sISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheet\"s & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 36 | Short point (up to 3 mtr.) |
| 37 | Medium point (up to 6 mtr.) |
| 38 | Long point(up to 10 mtr.) |
| 39 | Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it\"s ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheet\"s & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 40 | S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 41 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 42 | P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 43 | Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 44 | Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 45 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 46 | Providing & Fixing ofextra down rod of 15 mm dia . ERW (Electrical resistance welded ) of 1.6mm nominal thick medium duty steelpipe including cutting, threading, drilling, fixing quarter pin etc as reqd.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 47 | Providing & Fixing of IP 20 boxmade outfrom 1.2mm thick CRCA sheet steel with depth of minimun 30 mm and finished with powder coating andsuitable for mounting LED tubeincludingside covers, holders , internal wiring to illuminate the single sided connection LED tube. ( Without tube).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 48 | Providing & Fixing of 240/415 V isolatorISI marked IS:13947-III/conforming to IEC 60947-3, suitable for AC22A utilization category, 4KV impulse withstand voltage,true contact indication,Red colour dolly / lever shall have single mould covering over all poles for operation , two position din rail mounting,minimum phase termination capacity of 35sq.mm.IP 20 contact protection and fitted in existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |