Public Works Department-PWD has published Vertical Extension Of New Court Building Multistoried Court Building (G+2 To G+3 ) In The In The Premises Of Addl. District& SessionjudgeS, Khowai Sub-Division, District Khowai, Tripura / Sh: Building Portion Including Internal Water Supply And Sanitary . Submission Date for this Tender is 26-09-2023. Fire Alarm Systems Tenders in khowai Tripura. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Wiring for light/ fan/ exhaust fan/ call bell point with 2x1.5 sq. mm PVC insulated copper conductor cable (FR) in existing PVC conduit (medium gauge) recessed in slab/ wall complete with 6/10 amps modular type switch, cover plate, GI box including necessary connection etc. as required.:-(As per TSR-2021, Sl. No-501) |
2 | Providing and fixing of 3 pin 6/10 amps plug point withmodulartype 6/10ampsswitch andsocketincludingconnectionwith 2 x 1.5 sq. mm PVC insulated Copper conductor cable (FR) onmodular concealedswitch board with cover plate earthing the 3rd pin etc. as required. (As per TSR-2021 Sl. No.403) |
3 | Providing and fixing of 3/6 pin 16 / 20 amps plug point withmodulartype 16/20ampsswitch andsocketincludingconnectionwith 2 x 2.5 sq. mm PVC insulated Copper conductor cable (FR) onmodular concealedswitch board with cover plate earthing the 3rd pin etc. as required:- (As per TSR-2021 Sl. No.404) |
4 | Supplying and installation of industrial plug & socket complete with metal enclosure including necessary connection etc. as required of the following ratings (without MCB):-(As per TSR-2021 Sl.No.1207) |
5 | 20 amps 230/240 volts single phase suitable for SP/SPN/DP MCB:- |
6 | Wiring for Circuit/Sub-main with the following sizes of PVC insulated Copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/surface including connection etc. as required:- (As per TSR-2021, Sl. No.503) |
7 | 2 X 1.5 sq. mm |
8 | 2 X 2.5 sq. mm |
9 | 2 X 4 sq. mm |
10 | 2 X 6 sq. mm |
11 | 4x 10 sq.mm |
12 | 4x 16 sq.mm |
13 | 4x 25sq.mm |
14 | 1x1.5 sq.mm |
15 | 1 X 2.5 sq mm |
16 | 1 X 4 sq. mm |
17 | 1 X 6 sq. mm |
18 | 1 X 10 sq. mm |
19 | Supplying and fixing of the following PVC conduit (medium gauge) with all accessories on slab/recessed on wall etc as required.:-(As per TSR-2021, Sl. No.603) |
20 | 19/20 mm dia |
21 | 25 mm dia |
22 | 32 mm dia |
23 | Supplying & installation of metalic fan clamp box of standard size with 3mm thick bakelite/plastic cover as required:-(As per TSR-2021, Sl. No.823) |
24 | Supplying and fixing of following surface/recess mounted LED luminaries in powder coated die cast housing complete with high efficiency polycarbonate diffuser and necessary connection etc.as required (with 50000 burning hours and minimum lumen output of 100 lm/watt):-(As per TSR-2021 Sl. No.1101) |
25 | Surface mounted round/Square shaped 18/20 watt LED downlight with integral driver and high quality polycarbonate diffuser:- |
26 | Surface mounted box type batten suitable for single 18/20 watt integrated LED tube lamp (without lamp):- |
27 | Supplying and fixing of following LED Tubes, retrofit bulbs/lamps for LED luminaries including necessary connection etc. as required:-(As per TSR-2021 Sl. No.1103) |
28 | 18/20 watt LED tube with integral driver and polycarbonate diffuser (50000 burning hours and minimum lumen output of 100lm/watt):- |
29 | 9 watt LED retrofit lamp with polycarbonate body and aluminium heatsink :- |
30 | Supplying and fixing of following outdoor LED luminaries in powder coated die cast housing complete with heat resistant tempered glass/diffuser including necessary connection etc. as required (50000 burning hours and minimum lumen output of 100 lm/watt):-(As per TSR-2021 Sl. No.1102) |
31 | 90 watt LED street light fixture with integral driver and secondary lens (IP 66):- |
32 | Supplying & fixing of 1200 mm sweep white color AC ceilingfan capacitor typedouble ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated Copper conductor cable(FR)(ISI marked, BEE 1star/minimum service value 4.0 m3/min/W) : -(As per TSR-2017 Sl. No.802) |
33 | Supplying and fixing of 20 mm dia extra down rod (GI Pipe Medium Guage) with necessary hole for installation of ceiling fan as required.(As per TSR-2017 Sl. No.830) |
34 | Supplying & installation of 225/230 mm sweep metalic body exhaust fan including connection etc as required:-(As per TSR-2021 Sl. No.816) |
35 | Supplying & installation of 300 mm sweep 900 rpm metalic body exhaust fan including connection etc as required (ISI marked):-(As per TSR-2021 Sl. No.818) |
36 | Supplying & installation of shutter for 225/230/300 mm sweep metalic body exhaust fan in the existing hole as required:-(As per TSR-2021 Sl. No.821) |
37 | Making different sizes of hole in the wall for fixing of exhaust fan including finishing the same with cement plastering and painting etc as required:-(As per TSR-2021 Sl. No.831) |
38 | Supplying and fixing of the following electrical accessories including necessary connection etc. as required.(As per TSR-2021, Sl. No.604) |
39 | Ding dong call bell |
40 | Musical call bell |
41 | 32 amps DP kit kat switch:- |
42 | 3mm thick bakelite sheet |
43 | Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/415 volts MCB/Isolator/RCCB (SP / SPN / DP / TP / TPN / FP)complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connectionas required.(As per TSR-2021 Sl. No.1208):- |
44 | 2 way SPN MCB DB (single door):- |
45 | (2+6) / 8way SPN MCB DB (double door):- |
46 | 6way horizontal TPN MCB DB (Double door):- |
47 | 8way vertical TPN MCB DB suitable for FP MCCB incomer upto 125 amps (Double door):- |
48 | Supplying & installation of 10 KA breaking capacity, B/C curve MCB of following ratings in the existing MCB DB including connectionas required:-(As per TSR-2021 Sl.No.1215) |
49 | 6 to 32 amps SP MCB:- |
50 | 40/50/63 amps TP MCB:- |
51 | Supplying & installation of isolators of following ratings in the existing MCB DB including connection etc as required:- (As per TSR-2021 Sl.No.1217) |
52 | 40 amps DP isolator:- |
53 | Supplying & installation of TP/FP MCCB of following ratings in the existing MCCB enclosure/ panel board including connection etc as required (Ics=100% of Icu with adjustable settings):-(As per TSR-2021 Sl.No.1219) |
54 | 125 amps FP MCCB, Breakingcapacity 25KA (Thermal Magnetic) :- |
55 | 125 amps TP MCCB, Breakingcapacity 25KA (Thermal Magnetic):- |
56 | Supplying and fixing of the following modular accessories including necessary connection etc. as required. (As per TSR-2021 Sl.No.609) |
57 | 20/25 amps single phase motor starter switch (2M):- |
58 | RJ45 LAN socket outlet (1M):- |
59 | Bell push SP (1M) :- |
60 | 5 step fan regulator (2M):- |
61 | Blank plate (1M):- |
62 | Supplyingand fixingof UTP-4 pair Cat-6E LAN Cable in existingPVC conduit i/c necessary connection etc as required.(Finolex / Havells) (As per ref.No.F.5(205) / ACE/PROJECT/2017/8383-85 Dated:14/3/2018.) |
63 | Earthing with copper earth plate 600 mm x 600 mm x 3 mm thick i/c accessories and providing masonry enclosure withCIcover plate Size 12"x 12" having locking arrangement, alongwith20 mm dia (medium gauge) watering pipe including CC work etc as required:-(As per TSR-2021, Sl. No.703) |
64 | Extra for using salt (12 kg) and charcoal (96kg) for plate earth electrode as required.(As per TSR-2021,Sl. No.705) |
65 | Supply and fixing of 25 x 3mm copper strip on wall/ floor of the building for horizontal/ vertical run including necessary spacers and porcelain insulators at regular intervals:-(As per TSR-2021 Sl. No.714) |
66 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering,shuttering, finishing and reinforcement- 1:2:4 ( 1 Cement: 2 fine sand : 4 graded well burnt brick aggregate 20 mm nominal size):-(As per TSR-2021 Sl. No.1509) |
67 | 6 mm cement plaster in single layer including cost of materials required and finishing even and smooth and curing complete. In cement mortar 1 : 4 ( 1 cement : 4 fine sand ):-(As per TSR-2021 Sl. No.1521) |
68 | Neat cement punning:-(As per TSR-2021 Sl. No.1522) |
69 | Supplying, installation, testing and commissioning of following ratings inverter with Square/ sine wave technology, noiseless operation, inbuilt advance PCB programming, microprocessor with all accessories including necessary connections etc. as required:-(As per TSR-2021 Sl. No.1602) |
70 | 1500VA, 24V DC, 1 Ph input/1 Ph output inverter(Sine wave technology):- |
71 | Supplying, installation, testing and commissioning of following ratings Valve regulated lead acid(VRLA) battery with all accessories including necessary connections etc. as required:-(As per TSR-2021 Sl. No.1603) |
72 | 12 V/ 200AH tall tubular/ flat plate Battery:- |
73 | Supplying and fixing of MS frame made of (25mm x 25mm x 5mm) MS angle with necessary support by (40mm x 6mm) MS flat and 12 mm thick marine plywood on top, grouted on wall with 4 noslegs (25mmx25mmx5mm MS angle20 cm long) finishedwith red oxide and 2 coat synthetic enamel paintincluding necessary cc work, mending the damages & painting etc as required:-(As per TSR-2021 Sl. No.1502) |
74 | Supplying and laying of the following sizes XLPE insulated PVC sheathed aluminium conductor armoured cable with necessary connection etc as required(As per TSR-2021 Sl. No.1301) |
75 | 2 core 4 Sq mm |
76 | Drawing of armoured/un-armoured cable with proper saddling etc as required:-(As per TSR-2021 Sl. No.1511) |
77 | Supplying & fixing of G.I. pipe (medium gauge) bracket fabricated at suitable angle for fixing of outdoor light on wall/ RCC base with necessary MS clamp, nut, bolt etc as required:-(As per TSR-2021 Sl. No.1501) |
78 | 40 mm dia |
79 | Supplying, installation, testing & commissioning sector panelsuitable for following zones, complete with visual indications forshort circuit fault, open circuit fault, fire condition and allotherstandard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections,interconnections as required.(As per TSR-2021 Sl. No.1709) |
80 | 4 Zone |
81 | Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with allconnections etc. as required. (As per TSR-2021 Sl. No.1702) |
82 | Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required (As per TSR-2021 Sl. No.1703) |
83 | Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S.box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required. (As per TSR-2021 Sl. No.1706) |
84 | Supplyingandinstallation ABCpowder (MAP 90) fire Extinguisher ofcapacity 6 Kgwith fiveyearswarranty asrequired.(Make: Cease Fire/Fire shield, orapprovedbythe Engineer-in Charge)(As per Agreement No:- 27/EE-IED/AMB/2018-19) |