Tender For Sant Tukaram Natyagruh Electrical Work, Aurangabad-Maharashtra

Smart City Development Corporation Limited has published Tender For Sant Tukaram Natyagruh Electrical Work. Submission Date for this Tender is 20-09-2023. Bags Supply Tenders in Aurangabad Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

39594728
Tender For Sant Tukaram Natyagruh Electrical Work
Open Tender
Indian
Maharashtra
Aurangabad
20-09-2023

Tender Details

Tender For Sant Tukaram Natyagruh Electrical Work- 1 Supplying And Laying Rigid Steel Conduit 16 Swg 25 Mm Dia. With Necessary Accessories In Rcc Work / False Ceiling / False Flooring As Per Specification No: Wgma / Cc. ( 1-1-4 ) 2 Supplying And Erecting Hms Pvc Conduit Frls Grade 25 Mm Dia. With Necessary Accessories In Wall / Floor With Chiselling Appropriately As Per Specification No: Wg-Ma / Cc ( 1-1-9 ) 3 Supplying And Layinghms Pvc Conduit Frls Grade 25 Mm Dia With Necessary Accessories In Rcc Work / False Ceiling / False Flooring As Per Specification No. Wg-Ma / Cc ( 1-1-10 ) 4 Supplying And Erecting Hms Pvc Conduit Frls Grade25 Mm Dia. With Pvc Accessories On Wall / Ceiling As Per Specification No: Wg-Ma / Con. ( 1-2-4 ) 5 Supplying And Erecting Mains With 2X1.5 Sq.Mm Frlshcopperpvc Insulated Wire Laid In Provided Conduit / Trunking / Inside Pole / Bus Bars Or Any Other Places As Per Specification No: Wg-Ma / Bw ( 1-3-1 ) 6 Supplying And Erecting Mains With 2X2.5 Sq.Mmfrlsh Copper Pvc Insulated Wire Laid In Provided Conduit / Trunking / Inside Pole / Bus Bars Or Any Other Places. As Per Specification No: Wg-Ma / Bw ( 1-3-2 ) 7 Supplying And Erecting Mains With 3X4 Sq.Mm Frlsh Copper Pvc Insulated Wire Laid In Provided Conduit / Trunking / Inside Pole / Bus Bars Or Any Other Places As Per Specification No: Wg-Ma / Bw ( 1-3-7 ) 8 Supplying And Erecting Modular Type Switch 6A / 10A Duly Erected On Provided Plate And Box With Wiring Connections Complete. ( 1-6-1 ) 9 Supplying And Erecting Modular Type Switch 16Aduly Erected On Provided Plate And Box With Wiring Connections Complete. ( 1-6-2 ) 10 Supplying And Erecting Modular Type 3 Pin 6Amultisocket With Safety Shutter, Duly Erected On Provided Plate And Box With Wiring Connections Complete. ( 1-6-10 ) 11 Supplying And Erecting Modular Type 3 Pin 6 / 16Amultisocket With Safety Shutter, Duly Erected On Provided Plate And Box With Wiring Connections Complete. ( 1-6-11 ) 12 Supplying And Erecting Modular Type T.V. Socket Single Outlet, Duly Erected On Provided Plate And Box With Wiring Connections Complete. ( 1-6-14 ) 13 Supplying And Erecting Modular Type Telephone Socket One Gangwith Safety Shutter, Duly Erected On Provided Plate And Box With Wiring Connections Complete. ( 1-6-15 ) 14 Supplying And Erecting Modular Type Computer Jack Rj45 With Safety Shutter, Duly Erected On Provided Plate And Box With Wiring Connections Complete. ( 1-6-17 ) 15 Supplying And Erecting Modular Type ( Two Module ) Electronic Step Regulator For Fan, Duly Erected On Provided Plate And Box With Wiring Connections Complete. ( 1-6-23 ) 16 Supplying And Erecting Modular Type Blanking Plate Two Module, Duly Erected On Provided Plate & Box. ( 1-6-25 ) 17 Supplying And Erecting Unbreakable Concealed Type Modular Switch Box With Double Mounting Plate For 2 Module Duly Erected Flush To Wall With Required Chiselling And Finishing With Cement Mortar / Pop As Per Required To Match The Background. ( 1-6-35 ) 18 Supplying And Erecting Unbreakable Concealed Type Modular Switch Box With Double Mounting Plate For 3 Module Duly Erected Flush To Wall With Required Chiselling And Finishing With Cement Mortar / Pop As Per Required To Match The Background. ( 1-6-36 ) 19 Supplying And Erecting Unbreakable Concealed Type Modular Switch Box With Double Mounting Plate For 4 Module Duly Erected Flush To Wall With Required Chiselling And Finishing With Cement Mortar / Pop As Per Required To Match The Background. ( 1-6-37 ) 20 Supplying And Erecting Unbreakable Concealed Type Modular Switch Box With Double Mounting Plate For 6 Module Duly Erected Flush To Wall With Required Chiselling And Finishing With Cement Mortar / Pop As Per Required To Match The Background. ( 1-6-38 ) 21 Supplying And Erecting Unbreakable Concealed Type Modular Switch Box With Double Mounting Plate For 8 Module Duly Erected Flush To Wall With Required Chiselling And Finishing With Cement Mortar / Pop As Per Required To Match The Background. ( 1-6-39 ) 22 Supplying And Erecting Unbreakable Concealed Type Modular Switch Box With Double Mounting Plate For 12 Module Duly Erected Flush To Wall With Required Chiselling And Finishing With Cement Mortar / Pop As Per Required To Match The Background. ( 1-6-40 ) 23 Supplying And Erecting Unbreakable Concealed Type Modular Switch Box With Double Mounting Plate For 16 / 18 Module Duly Erected Flush To Wall With Required Chiselling And Finishing With Cement Mortar / Pop As Per Required To Match The Background ( 1-6-41 ) 24 Point Wiring For Light / Bell / Exhaust Fan In 20 Mm Frls Grade Hms Pvcconduit With 1.5 Sq.Mm ( 2+1E ) Frlsh Grade Copper Wire, Modular Type Switch, Earthingand Required Accessories As Per Specification No: Wg-Pw / Sw. ( 1-7-12 ) 25 Point Wiring For Ceilingfan In 20 Mm Frls Grade Hms Pvc Conduit With 1.5 Sq.Mm ( 2+1E ) Frlsh Grade Copper Wire, Modular Type Switch, Earthingand Required Accessories As Per Specification No: Wg-Pw / Sw ( 1-7-13 ) 26 Point Wiring For Independent Plug In 20 Mm Frls Grade Hms Pvc Conduit With 1.5 Sq.Mm ( 2+1E ) Frlsh Grade Copper Wire, Modular Type Switch, Earthing And Required Accessories As Per Specification No: Wg-Pw / Sw ( 1-7-14 ) 27 Point Wiring For Light / Bell Hybrid Type ( Surface Type Under False Ceiling And Concealed Type For Drops & Switch Boards On Walls ) In Min 20 Mm Pvc Conduit / Casing N Capping With 1.5 Sq.Mm. ( 2+1E ) Frlsh Grade Copper Wires, Modulartype Switch, Earthing And Required Accessories As Per Specification No: Wgpw / Hw ( 1-7-15 ) 28 Point Wiring For Ceiling Fan ( Surface Type Under False Ceiling And Concealed Type For Drops & Switch Boards On Walls ) In Min 20 Mm Pvc Conduit / Casing N Capping With 1.5 Sq.Mm. ( 2+1E ) Frlsh Grade Copper Wires, Modular Type Switch, Earthing And Required Accessories As Per Specification No: Wg-Pw / Hw 29 Wiring For Plug On Board Withswitch Socket Surface / Concealed Type, Copper Wiring And Earthing And With Modular Accessories As Per Specification No: Wg-Pw / Cw ( 1-7-26 ) 30 Supplying And Erecting 2 Pair Telephone Copper Cable 0.5 Mm Dia. With High Density Polyethylene Insulation, Polyester Taped, Nylon Rip Cord & Grey Colour Sheathed With Fr Pvc, Conforming To Itd Specification S / Ws 113C Laid In Provided Pvc Casing Capping / Conduit As Perspecification No. Wg-Tw ( 1-8-1 ) 31 Supplying And Erecting 50 Pair Telephone Copper Cable 0.5 Mm Dia. With High Density Polyethylene Insulation, Polyester Taped, Nylon Rip Cord & Grey Colour Sheathed With Fr Pvc, Conforming To Itd Specification S / Ws 113C Laid In Provided Pvc Casing Capping / Conduit As Perspecification No. Wg-Tw ( 1-8-7 ) 32 Supplying And Erecting 15M Vga Cord Low Voltage Gradeto Be Laid In Provided Conduits And Terminating With Male / Female Vga Connectors Complete. ( 1-8-20 ) 33 Supplying, Erecting And Commissioning Ofmdf Box 50X50 Pairs Made From Min. 1.5Mm Thick Ms Sheet As Per Specification No. Wg-Tw ( 1-9-1 ) 34 Supplying And Installingexpansion Cabinet For Extension Of Digital Hybrid Epabx To Expand System By 32 Ports With Programming And Configuration Of Extensions And Direct Lines With Required Accessories Complete. ( 1-9-33 ) 35 Supplying And Installingcat-6 Cable Suitable For Networking As Per Specification No. Wg-Coc / Nc ( 1-10-1 ) 36 Supplying, Fixing, And Configuring8-Ports Managed Gigabit, Layer-2 Switch, 10 / 100 / 1000 Base-T, Poe Smart Switch Plus 2 Sfp Erected In Provided Rack Complete. ( 1-11-2 ) 37 Supplying, Installing & Testing Utp Connector ( Rj-45 ) As Per Specification No. Wg-Nas / Utpc. ( 1-12-1 ) 38 Supplying And Fixing42 U Floormount Server Rack ( Dimension-Dxwxh – 800X1000x2070 Mm ) As Per Specification No. Wg-Nas / Rak ( 1-12-29 ) 39 Supplying And Erecting Led Square / Circular Max. 18 W Down Lighter / Panel Light Having Pressure Die-Cast Aluminium Housing, Polystyrene Diffuser Having System Lumens Output Of Min. 2000 Lumens, Min. Efficacy Of 110 Lumen / W, Cri>80, Cct Upto 6500K, Beam Angle Of 120 Deg., Max. Ripple Of 5%, Thd<10%, P.F. >0.95, Operating Range Of120-270V, Surge Protection Of 2.5 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver, Having Mounting Arrangement With Board For Surface Type Or Spring Loaded Mounting Clips Complete With 3 Years Warranty. ( 2-1-5 ) 40 Supplying And Erecting Led Square / Circular Max. 25 W Down Lighter / Panel Light Having Pressure Die-Cast Aluminium Housing, Polystyrene Diffuser Having System Lumens Output Of Min. 2750 Lumens, Min. Efficacy Of 110 Lumen / W, Cri>80, Cct Upto 6500K, Beam Angle Of 120 Deg., Max. Ripple Of 5%, Thd<10%, P.F. >0.95, Operating Range Of120-270V, Surge Protection Of 2.5 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver, Having Mounting Arrangement With Board For Surface Type Or Spring Loaded Mounting Clips Complete With 3 Years Warranty. ( 2-1-6 ) 41 Supplying And Erecting Ledpanel Light ( 600Mm X 600Mm ) Max. 35 Whaving Crca Powder Coated Housing, Polystyrene Diffuser Havingsystem Lumens Output Of Min 4200 Lumens, Min. Efficacy Of 120 Lumen / W, Cri>80, Cct Upto 6500K, Beam Angle Of 120 Deg., Max. Ripple Of 5%, Thd<10%, P.F. >0.95, Operating Range Of120-270V, Surge Protection Of 2.5 Kv, Life Class Of 50, 000 Hrs. At L70b50including Driver, Having Mounting Arrangement With Board For Surface Type Or Spring Loaded Mounting Clips Complete With 3 Years Warranty. ( 2-1-8 ) 42 Supplying And Erecting Anodized Aluminium Corridor / Passage Light Led Fitting ( 4 Feet ) Max. 22Wwith High Transitivity Diffuser Withsystem Lumens Output Ofmin.2200 Lumens , Min. Efficacy Of 100 Lumen / W, Cri>80, Cct Upto 6000K, Beam Angle Of 110 Deg., Ripple<5%, Thd<10%, P.F. >0.95, Operating Range Of200-270V, Surge Protection Of 2 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver, With End Caps On Provided Pvc Block / Wooden Board With 3 Years Warranty. ( 2-1-18 ) 43 Supplying And Erecting Inverter Led Batten 20W Tube Light Fitting With Polycarbonate Housing, Heat Sink, Integrated Hf Electronic Driver, Min. 2600 Mah Lithium Ion Battery With Charging Time Of 8-10 Hours And Backup Time Of Min. 3 Hrs. With Minimum 25% Of Initial Watts Having Luminous Efficacy Of 100 Lumen / Watt, Cri>80, Cct Of 6500K And Thd<=20% Havinguseful Life Of Minimum 25000 Hrs. With Overheating Protection With 2 Years Warranty. ( 2-1-22 ) 44 Supplying And Erecting Uv Fly Killer / Bug Catcher Light Fittinghaving 2 X 20W Uv Tube Lights To Cover Min. Area Of 500 Sq.Ftwith Powdered Coated M.S. / Steel Body Suitable To Work On 230V, Ac Supply Having Top Mounting Arrangement With Ss Chain Complete And 3 Core 1 Mtr. Flexible Wire With 1 Year Warranty. ( 2-1-23 ) 45 Supplying And Erecting Ding Dong / Electronic Musical Type Call Bell With Heavy Duty Coilsuitable To Operate On 230V A.C. Supply Erected On Polished Double Wooden Block / Sunmica Block Of Suitable Size. ( 2-3-13 ) 46 Supplying And Erecting Exhaust Fan Medium Duty 230 V A.C. 50 Cycles 225 Mm. 1400 Rpm With Condenser Complete Erected In Position With Necessary Materials. Fan Motor With Moisture Proof Treatment And ‘E’ Class Insulation. ( 2-10-15 ) 47 Supplying And Erecting Energy Saving Bldc Ceiling Fan 230 V A.C. 50 Cycles 1200 Mm, Max. Energy Consumption Of28w Having Service Ratio ( Cmm / W ) Of Min. 8 , Pf>0.9, Thd<10% With Ir Remote Control / Compatible Speed Regulator, Temperature Rise Of Max. 40 Deg. C, Having External Mounted Control Pcb Completely Erected In Position As Per Specification No. Fg-Fn / Cf ( 2-10-22 ) 48 Supplying And Fixinganchor Type Fastener Fan Hook, With 2 Nos. Of 10 Mm Dia X 75 Mm Long With Necessary Materials For Ceiling Fan. ( 2-11-2 ) 49 Supplying And Erecting Fan Clamp Of 30 X 5 Mm. M.S. Flat Of Required Length And 10 Mm.M.S. Bolt And Nuts Erected With Necessary Hook Of 10 Mm. M.S. Round Bar And Painted. ( 2-11-3 ) 50 Supplying And Erecting ‘B’ Class G.I .Pipe / M.S. Pipe Down Rod Duly Painted For Fan Complete Erected With Pvc Three Core Flexible Cable 1 Sq. Mm Copper Pvc Wire. ( 2-11-6 ) 51 Providing Recess In Brick Wall Suitable For Erection Of Exhaust Fan Up To 450Mm. Sweep Complete With Grouting Of Nut, Bolts, Plastering And Colour Washing To Match The Colour Of The Wall For The Wall Thickness Of 225 Mm. ( 2-11-11 ) 52 Supplying And Erecting 20 Swg G.I Sheet Metal Cawl Rectangular / Round Shaped With 25 X 25X 3 ( Mm ) Angle Iron Frame, Metal Mesh To Avoid Birds Entry With Necessary Material, Suitable For Exhaust Fan Of 300 Mm As Per Specification No Fg-Fas / Msc ( 2-11-17 ) 53 Supplying And Erecting Storage Type Water Heater 25 Litres Capacity Having Standing Loss <0.511Kwh / 24Hour / 45°C, High Impact Resistance Engineering Plastic Body With Anti Corrosive High Grade Steel Inner Tank, Heating Element Having Hard Water & Corrosion Protection, With Minimum 3 Safety Protections ( I.E. Thermostat & Thermalfunctioncut-Out, Valve ) With Total Pressure 8 Bar Withstanding Capacity Duly Tested And Marking Sr. No. And Date Of Erection Complete. Specification No. Ap-Wh / Stwh ( 3-1-2 ) 54 Supplying, Erecting, Testing And Commissioning Ofself Contained Water Cooler 230 / 250V 50Hz Nominal Cooling Capacity Of 150 Litres Per Hour And Storage Capacity 150 Litres With Partially Stainless Steel Body As Per Specification No. Ap-Wcr / Wc ( 3-3-10 ) 55 Supplying, Installing, Testing And Commissioning Of10kva Capacity Onlinepure Sine Wave With Backup Time Of ....... Hrs. Pwm & Igbt Based Ups With 0.9 To Unity Output Pf, 3 Phase Input & 1 Phase Output Complete With All Protectionsas Per Specification No. Ap-Ups ( 3-7-6 ) 56 Supplying And Erecting 12V / 100Ah Smf Battery With Battery Terminal Wire, Duly Charged With 24 Months Warranty Complete. ( 3-8-12 ) 57 Supplying And Erecting On Load Four Pole Automatic Transfer Switch, 415V, 400A, 50 Hz With Enclosure, Flexibility Of Neutral Connection, Line And Load Reversibility, Changeover With Phase Barriers, Source Separator, Terminal Covers Along With Staggered Termination For Cable Connection And Ats Controller With Provision Of Time Delay Protection Of Ov, Uv, Phase Sequence Changing, Single Phasing And Event Logging, Connected With Provided Leads Complete Complying To Is / Iec 60947-3 Part-1 / 6 . ( 5-1-14 ) 58 Supplying, Erectingandmarking Spmcb 6A To 32A, C-Serieswith Rated Short - Circuit Breaking Capacity ( Icn ) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb ( 5-3-2 ) 59 Supplying, Erectingandmarking Spmcb 6A To 32A, B-Series With Rated Short - Circuit Breaking Capacity ( Icn ) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb ( 5-3-3 ) 60 Supplying, Erectingandmarking Spmcb 40A To 63A, B-Series With Rated Short - Circuit Breaking Capacity ( Icn ) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb ( 5-3-5 ) 61 Supplying, Erectingandmarking Dpmcb 6 A To 32 A, B-Series With Rated Short - Circuit Breaking Capacity ( Icn ) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb ( 5-3-7 ) 62 Supplying, Erectingandmarking Dpmcb 40A To 63A, C-Series With Rated Short - Circuit Breaking Capacity ( Icn ) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb ( 5-3-8 ) 63 Supplying, Erectingandmarking Tpmcb 6A To 32A, With Rated Short - Circuit Breaking Capacity ( Icn ) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb ( 5-3-10 ) 64 Supplying, Erectingandmarking Tpmcb 40A To 63A, With Rated Short - Circuit Breaking Capacity ( Icn ) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb ( 5-3-11 ) 65 Supplying And Erecting Triplepole And Neutral Distribution Board ( Tpndb ) , Sp / Tp Mcbs Total 4 Ways / 12 Poles, With Door, 1.2Mm Thickness Surface / Flushmounted, Ip 43 Protection On Iron / Gi Frame ( Vertical Busbar Type ) As Per Specification No. Sw-Swr / Mcbdb ( 5-4-4 ) 66 Supplying And Erecting Triplepoleand Neutral Distribution Board ( Tpndb ) , Sp / Tp Mcbs Total 8 Ways / 24 Poles, With Door, 1.2Mm Thickness Surface / Flush Mounted, Ip 43 Protection On Iron / Gi Frame ( Vertical Busbar Type ) As Per Specification No. Sw-Swr / Mcbdb ( 5-4-5 ) 67 Supplying And Erecting Triplepoleand Neutral Distribution Board ( Tpndb ) , Sp / Tp Mcbs Total 12 Ways / 36 Poles, With Door, 1.2Mm Thickness Surface / Flushmounted, Ip 43 Protection On Iron / Giframe ( Vertical Busbar Type ) As Per Specification No. Sw-Swr / Mcbdb ( 5-4-6 ) 68 Supplying And Erecting Single Pole And Neutral Distributionboard ( Spndb ) , With 2 Ways For Incoming And 6 Ways ( 6 Poles ) For Outgoing Sp Mcbs, With Door, 1.2Mm Thickness Surface / Flush Mounted, Ip 43 Protection On Iron / Gi Frame As Per Specification No. Sw-Swr / Mcbdb ( 5-4-8 ) 69 Supplying And Erecting Single Pole And Neutral Distributionboard ( Spndb ) , With 2 Ways For Incoming And 10 Ways ( 10 Poles ) For Outgoing Sp Mcbs, With Door, 1.2Mm Thickness Surface / Flush Mounted, Ip 43 Protection On Iron / Gi Frame As Per Specification No. Sw-Swr / Mcbdb ( 5-4-9 ) 70 Providing And Erecting 3 Pole Mccb, 415 V, 100A, Rated Short-Circuit Breaking Capacity 25 Ka ( Ics=100% Of Icu ) , Adjustable Thermal ( Overload ) Setting And Fixed Magnetic Setting With Provided Leads, Provision For Installation Of Shunt / Uv / Trip Alarm Contact.Mccb With Phase Barriers On Both Sides, Insulation Withstand Capacity 800V, No Line-Load Bias In Provided Enclosure / Panel As Per Specification No. Sw-Swr / Mccb ( 5-5-1 ) 71 Providing And Erecting 3 Pole Mccb 415V, 250A, Rated Short-Circuit Breaking Capacity 36 Ka ( Ics=100% Of Icu ) Adjustable Thermal ( Overload ) Setting And Adjustable Magnetic Setting With Provided Leads, Provision For Installation Of Shunt / Uv / Trip Alarm Contact And Mccb Should Have Phase Barriers Both Sides, With Insulation Withstand Capacity 800V, No Line-Load Bias In Provided Enclosure / Panel As Per Specification No. Sw-Swr / Mccb ( 5-5-3 ) 72 Providing And Erecting 3 Pole Mccb 415V, 400A, Rated Short-Circuit Breaking Capacity 36 Ka ( Ics=100% Of Icu ) , Adjustablethermal ( Overload ) Setting And Adjustable Magnetic Setting With Provided Leads, Provision For Installation Of Shunt / Uv / Trip Alarm Contact And Mccb Should Have Phase Barriers Both Sides, With Insulation Withstand Capacity 800V, No Line-Load Bias In Provided Enclosure / Panel As Per Specification No. Sw-Swr / Mccb ( 5-5-4 ) 73 Providing And Erecting 3 Pole Mccb 415V, 630A, Rated Short-Circuit Breaking Capacity 36 Ka ( Ics=100% Of Icu ) , Adjustable Thermal ( Overload ) Setting And Adjustable Magnetic Setting With Provided Leads, Provision For Installation Of Shunt / Uv / Trip Alarm Contact And Mccb Should Have Phase Barriers Both Sides, With Insulation Withstand Capacity 800V, No Line-Load Bias In Provided Enclosure / Panel As Per Specification No. Sw-Swr / Mccb ( 5-5-5 ) 74 Providing And Erecting 3 Pole Mccb, 415V, 800A, Rated Short-Circuit Breaking Capacity 50 Ka ( Ics=100% Of Icu ) , Adjustable Thermal ( Overload ) Setting And Adjustable Magnetic Setting With Provided Leads, Provision For Installation Of Shunt / Uv / Trip Alarm Contact And Mccb Should Have Phase Barriers Both Sides, With Insulation Withstand Capacity 800V, No Line-Load Bias In Provided Enclosure / Panel As Per Specification No. Sw-Swr / Mccb ( 5-5-6 ) 75 Supplying, Fixing, And Commissioning 4 Polercbo 6 / 10 / 16 / 20 / 25A, With Overcurrent, Rated Short-Circuit Breaking Capacity ( 10 Ka ) And Earth Leakage Protection, With 30 / 100 / 300 Ma Sensitivity And Short Circuit And Earth Leakage Trip Indications Per Specification No Sw-Rccb / Rcbo ( 5-6-12 ) 76 Supplying, Installing, Testing And Commissioning Ofair Circuit Breaker Manual Fixed Type, Non-Drawout Type, 650V, 1000A Rated At 50º C Without Deration, 12Kv Impulse, 4 Pole ( 100% Neutral Protection ) , 50 Ka ( Ics=Icu=Icw For 1S ) , With Standard Accessories With Ready To Close, Individual Fault Trip, Alarm And Tripindication, Mechanical And Electrical Anti Pumping, Soft / Hard Rating Plug ( Including Hard Rating Plug Ct ) With Micro-Processer Based Lcd Display Release With Lsig And Temperature Rise Protection & With 4 C / O Contacts For On-Off-Trip Indication, Min. 5 Event And Trip History On Breaker Display On Provided Iron Frame As Per Specification No. Sw-Swr / Acb ( 5-8-3 ) 77 Supplying And Erecting Metal Work In Crca Sheet Including Iron Work For Supportswith Fabrication Ofboxes, Panelboards, Etc. Including Cutting, Bending, Drilling, Welding, Riveting, Treated With Anti-Rust Treatment Andduly Powder Coated Or Paintedwith One Coat Of Red Lead Paint And 2 Coats Of Enamel Paint Complete. ( 6-1-1 ) 78 Supplying And Erecting Iron Work, Sheet Metal Work Consisting Of Crcasheets, Varioussectionsofiron, Plates, Chequeredplates, Rods, Bars, Mspipes, Etc. Forpanel Board Or Any Other Purpose With Bending, Cutting, Drilling And Welding Completeerectedatthepositionwith Necessarymaterialsdulypaintedwith One Coat Of Red Oxide And Two Coats Of Enamelpaint To Match The Switchgears Or As Per Directions By The Authority. ( 6-1-19 ) 79 Supplying And Erecting 250 Kvar, 3 Phase, 50 Hz., Power Contactors Derated For Microprocessor Apfc Controller With Mpp / App Type Capacitor With 525 V And Having Minimum Overcurrent Capacity Of 1.8 In, Peak Inrush Current Capacity 300 Inand Minimum Life 150000 Hours With , Consisting Of Suitable Steps Of Mpp / App Type Capacitor Unitswith Detuned Aluminium Filter 7% Reactors With Circuit Breaker As Main Incomer And Mccb For Each Branch Protection, As Per Specification No Cp-Ed / Apfc ( 6-7-17 ) 80 Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steelformed Wire Armoured ( Strip ) Cable 1100 V, 3½ Core 25 Sq. Mm. Aluminiumconductor Complete Erected With Glands & Lugs, On Wall / Trusses / Pole Or Laid Inprovided Trench / Pipe As Per Specification No. Cb-Lt / Al 81 Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steelformed Wire Armoured ( Strip ) Cable 1100 V, 3½ Core 35 Sq. Mm. Aluminiumconductor Complete Erected With Glands & Lugs, On Wall / Trusses / Pole Or Laid Inprovided Trench / Pipe As Per Specification No. Cb-Lt / Al 82 Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steelformed Wire Armoured ( Strip ) Cable 1100 V, 3½ Core 50 Sq. Mm. Aluminiumconductor Complete Erected With Glands & Lugs, On Wall / Trusses / Pole Or Laid Inprovided Trench / Pipe As Per Specification No. Cb-Lt / Al 83 Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formedwire Armoured ( Strip ) Cable 1100 V, 3½ Core 150 Sq. Mm. Aluminiumconductor Complete Erected With Glands & Lugs, On Wall / Trusses / Pole Or Laid Inprovided Trench / Pipe As Per Specification No. Cb-Lt / Al 84 Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steelformed Wire Armoured ( Strip ) Cable 1100 V, 3½ Core 300 Sq. Mm. Aluminiumconductor Complete Erected With Glands & Lugs, On Wall / Trusses / Pole Or Laid Inprovided Trench / Pipe As Per Specification No. Cb-Lt / Al 85 Supplying And Erecting G.I. Pipe ‘A’ Class75 Mmdia.Erectedfor Enclosingxlpearmouredcable On Wall / Poleas Per Specification No. Cb-Ce ( 7-6-4 ) 86 Providing And Erecting Hot Dipped Galvanised Cover Suitable For Perforated Type Cable Tray Manufactured From 18 Swg ( 1.2 Mm Thick ) Gi Sheet Of 200 Mm Width & 20 Mm Height Complete With Necessary Hardware. ( 7-11-12 ) 87 Providing And Erecting Hot Dipped Galvanised Cover Suitable For Perforated Type Cable Tray Manufactured From 18 Swg ( 1.2 Mm Thick ) Gi Sheet Of 500 Mm Width & 20 Mm Height Complete With Necessary Hardware. ( 7-11-15 ) 88 Providing Pipetype Earthing With 40Mm. Dia. G.I. Pipe Or 20 Mm Dia. G.I. Rodcomplete With All Materials Testing And Recording The Results As Per Specification No. Ea-Ep ( 9-1-4 ) 89 Supplying And Erecting Aluminium Strip Of High Purity Required Sizes Used For Earthing On Wall And / Or Any Other Purpose With Necessaryaluminiumclampsfixed On Wall Painted With Bituminous Paint With Joints Required As Per Specification No Ea-Ep. ( 9-2-1 ) 90 Supplying And Erecting Conventionalspike Typeair Termination Suitable To Carry Lightning Stroke Made Up Of Heavy Gauge40 Mm Dia Copper Pipe Of Standard Length With 5 Nos. Copper Spikes Fixed On Copper Ball As Air Terminals Duly Threaded In Copper Pipeerected On Provided Foundation Complete. ( 9-3-1 ) 91 Providing And Back Filling Ground Enhancing Compound 25 Kg Bag Complete. ( 9-3-2 ) 92 Supplying, Installation And Testing Of Maintenance Free Earthing Comprising Ofelectrode Of 17.2 Mm Diameter Low Carbon Steel With 250 Micron Molecularcopper Bonded Earthing Rod Of Length 3M Along With 25 Kg Carbon Basedenvironment Friendly Back Fill Ground Enhancing Compound Required To Fill Up Theexcavated Earth With Required Quantity Complete, And Recording The Resultsspecification No. Ea-Mobi ( 9.1.5 ) 93 Supplying, Erecting, Testing And Commissioning3- 10-Watt Smart Wired Led Ceiling Lamp Downlighter Wiz Connected ( Shades Of White / Warm White + Dimmable + Pre-Set Modes ) ( Non Csr ) 94 Supplying, Erecting, Testing And Commissioning Of Wall / Floor Mounted Three Phase 415 V Electronic Dimmer 12X4 Kw Having Rectangular Shape Semi Automatic / Dmx Type, With Ryb Indicator, Having 24 Input Jackwith Crca Housing Min 22 Gauge With All Internal Mcb, Wiring, Controlling Accessories Complete ( Non Csr ) 95 Supplying And Erecting Pvc Insulated Pvc Round Sheathed 1.5 Sq.Mm ( 30 No. X 0.25 Mm Dia. ) 3 Core Flexible Multi Stranded Copper Industrial Cable For Voltage Grade Up To 1.1 Kv ( 1-3-14 ) 96 Supplying And Erecting Integrated Led Street Light Fitting 60W Ip65 & Ik08 Class Having Single Piece Pressure Die-Cast Aluminium Housing, Havingsystem Lumens Output Of Min. 6600 Lumens, Min. Efficacy Of 110 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.95, Operating Range Of140-270V, Inbuilt Surge Protection Of 10 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver Complete With 3 Years Warranty As Per Specification Nofg-Odf / Fls2. ( 2-4-5 ) 97 Supplying And Erecting Three Phase, 415V, Street Light Control Panel Up To The Max Load Of 6Kw, Tpn Mcb 40A, Powder Coated Crca 14 Swg Sheet, Outdoor Type, Having Ip54, Ik10 Protection, Suitable Rating Contactor, 24 Hrs. Astronomical Time Switch With Minimum 5 Years Battery Back Up, Auto / Manual Selector Switch, On / Off Push Buttons, Indicator Lamps, Control Wiring, Metering Device, Etc. For Automatic Operation, With Overcurrent, Short Circuit, Earth Fault Protectionon Provided Iron Frame / Cc Foundation . ( 5-2-5 ) 98 Supplying, Erecting & Marking Spmcb 0.5A To 5A, C-Series With Rated Short - Circuit Breaking Capacity ( Icn ) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb ( 5-3-1 ) 99 Supplying, Erectingandmarking Tpmcb 40A To 63A, With Rated Short - Circuit Breaking Capacity ( Icn ) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb ( 5-3-11 ) 100 Supplying & Erecting Triple Pole And Neutral Distribution Board ( Tpndb ) , 3 Pole / 4 Pole Mccb As Incomer & Outgoing Sp Mcb ( 12 Poles ) Or Tp Mcb Of 4 Ways ( 12 Poles ) , With Door, 1.2Mm Thickness, Surface / Flush Mounted, On Iron / Gi Frame ( Vertical Busbar Type ) As Per Specification No. Sw-Swr / Mcbdb1 ( 5-4-15 ) 101 Supplying And Erecting Gi Sheet 1.6Mm ( 16 Swg ) Caution Board Of Size 250 X 200 Mm Duly Painted With Red Oxide And Enamel Paint In Marathi, Hindi And English Erected At Position For Hv / Ehv ( 11000 Volts ) Installation With Compliance To Is 2551-1982 ( 6-1-16 ) 102 Supplying And Erecting Iron Work, Sheet Metal Work Consisting Of Crcasheets, Varioussectionsofiron, Plates, Chequeredplates, Rods, Bars, Mspipes, Etc. Forpanel Board Or Any Other Purpose With Bending, Cutting, Drilling And Welding Completeerectedatthepositionwith Necessarymaterialsdulypaintedwith One Coat Of Red Oxide And Two Coats Of Enamelpaint To Match The Switchgears Or As Per Directions By The Authority. ( 6-1-19 ) 103 Supplying, Erecting & Terminating Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 4 Core 6Sq. Mm. Aluminium Conductor Completeerected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipeas Per Specification No. Cb-Lt / Al ( Note For Use Of Xlpe Insulation Instead Of Fr-Xlpe Insulated Armoured Cable Reduce Rates By 5 % ) ( 7-1-27 ) 104 Supplying, Erecting & Terminating Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 4 Core 25 Sq. Mm. Aluminium Conductor Completeerected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipeas Per Specification No. Cb-Lt / Al ( Note For Use Of Xlpe Insulation Instead Of Fr-Xlpe Insulated Armoured Cable Reduce Rates By 5 % ) ( 7-1-30 ) 105 Supplying Andlaying ( Including Excavation Of Suitable Width & Depth Up To 90 Cm ) 50 Mmoutside Dia. Double Wall Corrugatedpipes ( Dwc ) Ofhdpe For Enclosing Cable Below Ground / Road Surface, To Required Depth Complete. 106 Providing And Erecting 6 M High ( Clear Height ) Galvanised Octagonal Pole With Foundation Bolts Having Bottom Of 130 Mm A / F, Top 70 Mm A / F On Provided Foundation As Per Specification No. Oh-Pl / Opl ( 8-2-12 ) 107 Providing And Erecting Galvanised 1000Mm Single Arm Sword Type Bracket With Frp Dome And Ball As Per Specification No. Oh-Pl / Pbkt ( 8-2-21 ) 108 Providng Earthing With Galvanized Iron Earth Plate Size 60 X 60 X 0.6 Cm Complete With All Materials, Testing & Recording The Results As Per Specification No. Ea-Ep ( 9-1-1 ) 109 Providing Pipetype Earthing With 40Mm. Dia. G.I. Pipe Or 20 Mm Dia. G.I. Rodcomplete With All Materials Testing And Recording The Results As Per Specification No. Ea-Ep ( 9-1-4 ) 110 Supplying And Erecting Gi Strip Of High Purity Required Size Used For Earthing On Wall And / Or Any Other Purpose With Necessary Gi Clampsfixed On Wall Painted With Bituminous Paint With Joints Required. As Per Specification No Ea-Ep. ( 9-2-3 ) 111 Making Cement Concretefoundationin 1:3:6 Cement Concrete, ( 20 To 25 ) Mm. Stone Metal Duly Plastered With Necessary Curing Forcomplete. ( Pole Muffing Or Any Other Purpose ) . ( 16-3-7 ) 112 Makingm- 20 Grade Reinforced Cement Concretefoundation By Considering The Safe Soil Bearing Capacity At Site As 10 T / Sq.Mat 1.5 M Depth Including Supply Of Steel, Concrete, Excavation And Fixing Provided Nut Bolts With The Help Of Template, Duly Plastered As Per Design Complete ( For 6M To 8M High Octagonal / Conical Gi Pole ) . ( 16-3-9 ) 113 Supplying, Erectingandmarking Tpmcb 40A To 63A, With Rated Short - Circuit Breaking Capacity ( Icn ) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb ( 5-3-11 ) 114 Supplying, Fixing, And Commissioning Mcb Type Change Over Switch 4 Pole, 40A With 3 Positions ( I-O-Ii ) With Centre Off Position As Per Specification No. Sw-Swr / Mcbcos ( 5-3-25 ) 115 Supplying And Erecting Crca Sheet Metal One Way Enclosures Of 1.2Mm Thickness Suitable For Dp Mcb / Tp Mcb / Fp Mcb / Rccb / Rcbo Complete Erected On Angle Iron / Gi Frame. ( 5-4-13 ) 116 Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 4 Core6sq. Mm. Aluminium Conductor Completeerected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipeas Per Specification No. Cb-Lt / Al ( 7-1-27 ) 117 Supplying And Erecting G.I. Pipe‘A’ Class 40 Mmdia.Erectedfor Enclosingxlpearmouredcable On Wall / Poleas Per Specification No. Cb-Ce ( 7-6-2 ) 118 Supplying And Laying ( Including Excavation ) Of Suitable Width & Depth Up To 90 Cm ) 50 Mmoutside Dia. Double Wall Corrugatedpipes ( Dwc ) Ofhdpe For Enclosing Cable Below Ground / Road Surface, To Required Depth Complete. ( 7-6-9 ) 119 Providing Earthing With Galvanizediron Earth Plate Size 60 X 60 X 0.6 Cm With Funnel With A Wire Mesh For Watering And Brick Masonry Block C.L. Covercomplete With All Materials, Testing & Recording The Results Asper Specification No. Ea-Ep ( 9-1-3 ) 120 Providing Pipetype Earthing With 40Mm. Dia. G.I. Pipe Or 20 Mm Dia. G.I. Rodcomplete With All Materials Testing And Recording The Results As Per Specification No. Ea-Ep ( 9-1-4 ) 121 Supplying And Erecting Minimum Three & Above Star Rated Submersible Pump Set Of 2.25 Kw / 3 Hp With 415 V, 50 C / S Ac Supply Suitable For 100 Mm Dia. Borewell Suitable For 60 To 170 Lpm Discharge At 97 To 30 M Head & Discharge & Delivery Pipe Of Size-40 Mm Diameter With A Necessary H Type Clamps As Per Specification No. Wp-Smp 122 Supplying And Erecting Minimum Three & Above Star Rated Submersible Pump Set Suitable For Erection On Open Well Of 5.625 Kw / 7.5 Hp With 415 V 50 C / S. A.C. Supply, Having Delivery Head From 36 To 14M And Discharge From 225 To 1680 Litres. Per Minute& Pipe Of Suction 75 Mm / Delivery 65 Mm Diameter Erected With Necessary H Type Clamps As Per Specification No. Wp-Osp ( 12-3-3 ) 123 Supplying And Erecting Flat Flexible 3 Core 2.5 Sq.Mm Pvc Sheathed Submersible Type Copper Cable Suitably Clamped At Fixed Intervals With Column Pipe Assembly Complete. ( 12-4-8 ) 124 Supplying And Erecting Flat Flexible 3 Core 4 Sq.Mm Pvc Sheathed Submersible Type Copper Cable Suitably Clamped At Fixed Intervals With Column Pipe Assembly Complete. ( 12-4-9 ) 125 Supplying And Erecting Water Level Controller 230 / 415 V, A.C. , Four Way Under Ground & Over Head Tank Operation Only. ( 12-4-15 ) 126 Supplying & Erecting Pvc Coated 5 Mm Dia. Brass Sensor / Electrode Duly Wired With Nuts & Bolts Complete ( Set Of 3 Nos ) . ( 12-4-15 ) 127 Supplying And Erecting Automatic Control Panel For 3 Phase , 415 Volt, A.C, Submersible / Centrifugal Pump Set Up To 7.5 Hp Consisting Of Dol Starter Having Relay Range 9-14 Amp, S.P.P., Combined Ammeter / Voltmeter, Phase Indicating Lamp Enclosed In Crca Powder Coated Vibration Proof Enclosure With Ip 54 Protection. Control Panel Should Offer Single Phasing, Phase Reversal, Phase Imbalance Etc . ( 12-4-17 ) 128 Excavating Hard Rock Or Bituminous Road By Chiselling For Preparing Pit For Pole / Stay / Earth Plate / For Laying Cable / Pipe & Clearing The Site By Removing Debris & Making The Site As Required Complete. ( 16-1-5 ) 129 Making Cement Concretefoundationin 1:3:6 Cement Concrete, ( 20 To 25 ) Mm. Stone Metal Duly Plastered With Necessary Curing Forcomplete. ( Pole Muffing Or Any Other Purpose ) . ( 16-3-7 ) 130 Supplying And Erecting Isi Mark Gi Pipe 50 Mm Dia.‘B’ Class At Position With Accessories Complete As Per Specification No. Cw-Plb / Gp. ( 16-5-6 ) 131 Supplying And Erecting Isi Mark Gi Pipe 75 / 80 Mm Dia. ‘B’ Class At Positionwith Accessories Complete. Specification No. Cw-Plb / Gp. ( 16-5-8 ) 132 Supplying And Erecting High Density Polythene Pipe Isi Mark 50 Mm. Dia. Suitable For Pressure Of 6 Kg. / Cm2 Connected Tojet / Submersible Pump With Required Material Complete. ( 16-5-18 ) 133 Supplying And Erecting 50 Mm Dia. Gun Metal Sluice Valve At Position With Necessary Materials Complete. ( 16-6-15 ) 134 Supplying And Erecting Non Return Valve 50 Mm Dia In Position Made Of Gun Metal Complete. ( 16-6-21 ) 135 Supplying And Erectinghms Pvc Conduit Frls Grade 25 Mm Dia. With Necessary Accessories In Wall / Floor With Chiselling Appropriately As Per Specification No: Wg-Ma / Cc. 1-1-9 136 Supplying And Laying Hms Pvc Conduit Frls Grade 25 Mm Dia With Necessary Accessories In Rcc Work / False Ceiling / False Flooring As Per Specification No. Wg-Ma / Cc. 1-1-10 137 Supplying And Erecting 25 Mm Dia. Corrugated Flexiblepolypropylene Conduit 1-2-2 138 Supplying And Erecting 10M Hdmi Cord Low Voltage Grademinimum 4K Compliant To Be Laid In Provided Conduits With Male / Female 19 Pin Hdmi Connectors Complete.. 1-8-23 139 Supplying And Installingcat-6 Cable Suitable For Networking As Per Specification No. Wg-Coc / Nc 1-10-1 140 Supplying, Fixing, And Configuring 24 Ports, Poe Switch In Provided Rack As Perspecification No. Wg-Nwc / Ens ( 1-11-3 ) 141 Supplying, Installing And Testing Utp Connector ( Rj-45 ) As Per Specification No. Wg-Nas / Utpc. 1-12-1 142 Supplying And Fixing 9U Wall Mount Rack ( Dimension-Dxwxh – 500X600x500 Mm ) As Per Specification No. Wg-Nas / Rak1-12-18 143 Supplying And Fixing 24 Ports Light Guide Unloaded Interconnect Unit, Wall Mounted Type, With Adapter Panel For Termination Of Optical Fibre Cables Onwall In Provided U Rack Complete As Per Specification No. Wg-Nas / Liu 1-12-8 144 Supplying, Installing, Testing And Commissioning Of2kva Capacity Online Pure Sine Wave, With Backup Time Of 03 Hrs. Pwm & Igbt Based Ups With 0.8 To Unity Output Pf, Single Phase Input & 1 Phase Output Complete With All Protections As Per Specification No. Ap-Ups ( 3-7-2 ) 145 Supplying And Erecting 12V / 100Ah Smf Battery With Battery Terminal Wire, Duly Charged With 24 Months Warranty Complete. ( 3-8-12 ) 146 Supplying, Erecting, Testing & Commissioning 5 Mp Full Ip Dome Camera Complete. Camera Sensor 1 / 2.7, 5.0 Megapixel, Progressive Scan, Cmoslens 2.8Mm@F2.0Dori Distance 42 Meter Detectshutter Auto / Manual, 1 ~ 1 / 100000S Colour: 0.01Lux ( F2.0, Agc On ) Minimum Illumination 0Lux With Ir Ondigital Noise Reduction 2D / 3D Dnrday / Night Ir-Cut Filter With Auto Switch ( Icr ) S / N >52Dbir Range Up To 30M ( 98Ft ) Ir Rangewavelength 850Nmir On / Off Control Auto / Manualdefog Digital Defogwdr Dwdrvideo Max. Resolution 2592 X 1944Video Compression Ultra 265, H.265, H.264, Mjpegh.264 Code Profile Baseline Profile, Main Profileframe Rate Main Stream: 5Mp ( 2592*1944 ) , Min 25Fps; Sub Stream: 720P ( 1280×720 ) , Min 20Fpsvideo Bit Rate 128 Kbps~16 Mbpsosd Up To 4 Osdsprivacy Mask Up To 4 Areasroi Up To 2 Areasmotion Detection Up To 4 Areasimage White Balance Auto / Outdoor / Fine Tune / Sodium Lamp / Locked / Auto2digital Noise Reduction 2D / 3D Dnrsmart Ir Supportflip Normal / Vertical / Horizontal / 180°Dewarping Nahlc Supportedblc Supportednetwork Protocols Ipv4, Igmp, Icmp, Arp, Tcp, Udp, Dhcp, Rtp, Rtsp, Rtcp, Dns, Ddns, Ntp, Ftp, Upnp, Http, Https, Smtp, Ssl, Qosinterface 10 / 100M Base-Tx Ethernetcompatible Integration Onvif ( Profile S, Profile T ) , Apicertifications Certifications Ce: En 60950-1 / Ul: Ul60950-1 / Fcc: Fcc Part 15 ( Include – 12 Month Fully Compressive Warranty ) ( Rates Are As Per Sanct.Lt.No.431 Dt.22.03..2022 ) ( Non Csr ) 147 Supplying, Erecting, Testing & Commissioning 5 Mp Full Ip Bullet Camera Complete. Camera Sensor 1 / 2.7, 5.0 Megapixel, Progressive Scan, Cmoslens 4.0Mm@F2.0Dori Distance 60 Meter Detectshutter Auto / Manual, 1 ~ 1 / 100000S Colour: 0.01Lux ( F2.0, Agc On ) Minimum Illumination 0Lux With Ir Ondigital Noise Reduction 2D / 3D Dnrday / Night Ir-Cut Filter With Auto Switch ( Icr ) S / N >52Dbir Range Up To 30M ( 98Ft ) Ir Rangewavelength 850Nmir On / Off Control Auto / Manualdefog Digital Defogwdr Dwdrvideo Video Compression Ultra 265, H.265, H.264, Mjpegh.264 Code Profile Baseline Profile, Main Profileframe Rate Main Stream: 5Mp ( 2592*1944 ) , Min 25Fps; Sub Stream: 720P ( 1280×720 ) , Min 20Fpsvideo Bit Rate 128 Kbps~16 Mbpsosd Up To 4 Osdsprivacy Mask Up To 4 Areasroi Up To 2 Areasmotion Detection Up To 4 Areasimage White Balance Auto / Outdoor / Fine Tune / Sodium Lamp / Locked / Auto2digital Noise Reduction 2D / 3D Dnrsmart Ir Supportflip Normal / Vertical / Horizontal / 180°Dewarping Nahlc Supportedblc Supportednetwork Protocols Ipv4, Igmp, Icmp, Arp, Tcp, Udp, Dhcp, Rtp, Rtsp, Rtcp, Dns, Ddns, Ntp, Ftp, Upnp, Http, Https, Smtp, Ssl, Qosinterface 10 / 100M Base-Tx Ethernetcompatible Integration Onvif ( Profile S, Profile T ) , Apicertifications Certifications Ce: En 60950-1 / Ul: Ul60950-1 / Fcc: Fcc Part 15 ( Non Csr ) 148 Supplying, Erecting, Testing & Commissioningcamera Nvr 32 Channel System Specifications :32Ch With 4K Real-Time Live Preview Max 32Q Mbps Incoming Bandwidth With H.265 Compression, Decoding Support Upto 4 X 4K@30, 8 X 4Mp@20 On Vif Version 2.4 Conformance Vca Search And Smart Search For Playback Support 8 Sata Hdd Up To 64Tb With Raid Configuration, 2 Usb 2.0, 1 Usb. ( Non Csr ) 149 Supplying And Installation Testing & Commissioning Of Surveillance Internal Hdd ( Hard Disk Drive ) Internal Hdd Supply , Installation Testing And Commissioning For Surveillance Hddrecording Capacity 8Tb. ( Non Csr ) 150 Supplying, Erecting, Commissioning & Testing Screen ( 108 Cm ) / 40 Inchpecifications General O Screen Size : 108 Cm ( 43 ) • Screen Type : Led • Hd Technology & Resolution : Full Hd Tv, 1920 X 1080 • Hdmi : 3, Usb : 1 • Launch Year : 2018 Onnectivity Features : Hdmi, 2 Side : Usb O 1 Side Video Features • Contrast Ratio : Mega Contrast ( Static ) • Picture Engine : Hyper Real • View Angle : 178 Degree • Panel Type : A+, Digital Noise Filter : Yes • Led Display Type : Direct • Aspect Ratio16:09 • Refresh Rateo 60 Hz • Other Video Features O Pmi 300: Clarity, Color, Contrast, Active Noise Reduction, Dynamic Color Enhancer O Picture Mode: 8 Modes ( Vivid, Standard, Aps, Cinema, Cricket, Game, Expert1, Expert2 ) O Picture: Jpeg, Digital Noise Reduction, Movies Support In Usb Mode, Mpeg H.264 Decoder O Response Time: 6.5 Ms, Still Image, Wide Color Enhancer ( Plus ) , Film Mode, Cricket Mode Audio Features • Number Of Speakers : 2 • Speaker Type: Down Firing With Bass Reflex • Sound Technology : Dolby Digital Plus • Speaker Output Rms : 20 W Warranty • Warranty Summary : 1 Year Comprehensive And 1 Year Additional On Panel. ( Non Csr )

Key Value

Document Fees
INR 1000 /-
EMD
INR 85193.0 /-
Tender Value
INR 85.19 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail