}

Tender For Construction Of Common Facility Centre On Teracotta Crafts At Talpadar Dist-Bargarh, bargarh-Odisha

Orrisa Cooperative Tasar and Silk Federation Limited has published Tender For Construction Of Common Facility Centre On Teracotta Crafts At Talpadar Dist-Bargarh. Submission Date for this Tender is 25-09-2023. Building Work Tenders in bargarh Odisha. Bidders can get complete Tender details and download the document.




Tender Notice

39557000
Tender For Construction Of Common Facility Centre On Teracotta Crafts At Talpadar Dist-Bargarh
Open Tender
Indian
Odisha
bargarh
25-09-2023

Tender Details

Construction Of Common Facility Centre On Teracotta Crafts At Talpadar Dist-Bargarh

Key Value

Document Fees
INR 11800 /-
EMD
INR 61885.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: CONSTRUCTION OF COMMON FACILITY CENTRE (CFC) FOR STONE CARVING CRAFT AT TALPADAR, DIST-BARGARH.
Sl. No. Item Description
1Earthwork in excavation in alltypes of soil for site leveling, foundation, pits, trenchesand other civil works upto and including 1.5metre lift and stacking the soil upto a lead of 100 metre and including dewatering, removing slush,shoring and strutting (as required), complete as per specification and as directed by the Engineer-In-Charge.
2All kind of Soil
3Building Area
4Filling at all depth with available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 15cm in depth:consolidating each deposited layer by ramming and watering complete (lead upto 100m) as directed by the Engineer-In-charge.
5Supplying offilling sand in foundation and over areas including watering,ramming,consolidating and dressing, labours, tools, taxes etc., all complete as per the specification and direction of Engineer-In-charge.
6Providing and laying plain cement concrete 1:3:6 (1 cement : 3 sand : 6 stone agregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curring, shuttering etc. complete all depth and height.
7Providing and laying plain cementconcrete1:3:6 (1 cement:3 sand: 6 stoneagregate 12mmnominal size) as levelling course in foundation and plinth etc. includingtempering, curring ,shuttering etc.complete all depth and height.
8First class Fly ash Brick masonry usingbricks of size 25cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Foundation & Plinth including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-In-Charge.
9First class Fly ash Brick masonry usingbricks of size 25cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Super stracture including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-In-Charge.
10Ground Floor
11Terrace Floor
12First class Fly ash Brick masonry usingbricks of size 25m. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:4) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Super stracture including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-In-Charge.
13Ground Floor
14Providing, lifting, hoisting and laying Reinforced cement concrete of M-25 grade as per approved designs and drawings having a minimum compressive strength (in work test) 250 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed andcleaned ( 20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portlandslag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. But excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or tor steel tying the grills and placing in proper position.
15a) Footings :-
16b) Columnup to plinth :-
17c) Plinth beam :-
18d) Lintel
19Terrace Floor
20e) Column in S.S :-
21Ground Floor
22Terrace Floor
23f) Beam
24Ground Floor
25Terrace Floor
26g) Slab
27Ground Floor
28Terrace Floor
29h) Staircase
30Ground Floor
31Supplying, straightening, cutting, bending, placing in position and binding reinforcement steel work in RCC reinforced brick works as per drawing and specification including preparation of respective bar bending schedule and binding ( Bindingwire to be used as per the IS code) etc. all complete as per direction of Engineer-in-charge.Cold Twisted bars, Thermo Mechanicallytreated bars.
32Ground Floor
33Terrace Floor
3412mm cement plaster on external RCC/brick surfaces incement plaster 1:6 (1 cement : 6 coarse sand) including necessary scaffolding, curing etc. all complete at all floors and all heights.
35Ground Floor
36Terrace Floor
3716mm cement plaster on internal smooth side of RCC/brick surfaces with cement mortar of mix 1:6 (1 cement : 6 fine sand) including necessary scaffolding, curing etc. all complete at all floors and all heights.
38Ground Floor
39Terrace Floor
406 mm cement plaster on internal smooth side of RCC/brick surfaces with cement mortar of mix 1:4 (1 cement : 4fine sand) including necessary scaffolding, curing etc. all complete at all floors and all heights.
41Ground Floor
42Terrace Floor
43Providing & Fixing of WPC Door Frame size 5" x 2.5" having density 725kg/m3, make up of virgin polymer, wheat and rice husk fiber and Calcium silicate. 100% water proof, termite proof and fire retardant made of Alstone Chaukhat. The door will be provided with all necessary fitting & fixture of approved hardware and all materials complete as per direction of the Engineer-In-Chareg.
44Ground Floor
45Providing & fixing WPC Door Shutter of thick 30mm having density 660kg/m3 make up virgin polymer with wheat and rice husk fiber. 100% water proof, termite proof and fire retardant made of Alstone WPC Door. The door will be provided with all necessary fitting & fixture of approved hardware and all materials complete as per direction of the Engineer-In-Chargeat all floors and all heights.
46Ground Floor
47Providing and fixing Steel work welded in built up section/framed Rooling shutter/Gtae/Grill (including M.S. angle,plate, sq.bar, flat, m.s.tubular section, Heavy type hinges) work incuding cutting, hoisting, fixing in position and applying apriming coat of approved steel primer, two or more coats of synthetic enamel paint with approved make and brand in grating, frames, guard bar, ladder, railings for balconies and straircase, brackets, gates and similar works as per direction of Engineer-In-Charge. (All structural steel contractor"s own supply).
48Ground Floor
49Terrace Floor
50Providing and fixing of factory made (NCL/VEKA LTD or equivalent )of colour UPVC sliding window or openable (approved colour of Frame ) complete with U value=1.9-1.3 W/m 2k/3k, flame resistance, self extinguishing, lead free comprising colour UPVC multi chambered frame having in built UPVC roller track on top and UPVC sash with wall thickness of 2.3mm duly reinforced with G.I section 2.6 mm where ever required. All corners of frame and sash will be fusion welded. After placing12.5mm laminate glass (6mm clear toughtened +1.5 pvg laminate+5mm clear glass) Annealed glass in the sash, with suppord of hurricane bar for high wind support. uPVC glazing bead, interlock, EPDM gasket brush shall be provided including multi lock and rollers & proper drainage system shall be provided. window frame will be fixed to the wall with 100mm long and 8mm dia.Fasteners and after fixing the gap between frame and adjucent finished wall shall be filled with weather proof silicon sealant over backer rod of required size, of approved quality complete in all respect as per approved drawing & direction of the Engineer -In-Charge.
51Ground Floor
52Terrace Floor
53Providing and laying Vitrified flooring tiles 600x600 mm (thickness to be specified by the manufacturer) 1st quality of NITCO, SOMANY, ASIAN, KAJARIA or equivalent approved make, colours & shades laid on 20 mm thick cement mortar 1:4 (1cement: 4coarse sand) including pointing the joints with white cement and matching pigments, etc. complete as per direction of Engineer-In-Charge at all floors and all heights.
54Ground Floor
55Providing and laying Vitrified kirtingtiles 600x600 mm (thickness to be specified by the manufacturer) 1st quality of NITCO, SOMANY, ASIAN, KAJARIA or equivalent approved make, colours & shades laid on 12 mm thick cement mortar 1:3 (1cement: 3coarse sand) including pointing the joints with white cement and matching pigments, etc. complete as per direction of Engineer-In-Charge at all floors and all heights.
56Ground Floor
57Providing and fixing 20mm thick Granite stone flooring(sample of Granitestone should be approved by EIC) for stair case trade, riser and similar locations where ever required in horizontal/vertical surfaces of required size of approved shade, colour and texture, with moulding edge & Grooving etc. laid over 25mm thick bed of cement mortar 1:1 (1 cement: 1 coarse sand) with joints treated with white cement mixed with matching pigment, epoxy touch ups including rubbing, curing, moulding and polishing to give high gloss finish etc. complete as per direction of Engineer-in-charge. In all floors and all heights.
58Ground Floor
59Providing and layingMatte Finish Vitrifiedfloor tiles 600x600 mm (thickness to be specified by the manufacturer) 1st quality conforming to IS: 15622 of NITCO, SOMANY, ASIAN, KAJARIA or equivalent approved make, colours & shades, except white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 (1cement:4coarse sand) including pointing the joints with white cement and matching pigments, etc. complete as per direction ofEngineer-In-Charge at all floors and all heights.
60Ground Floor
61Providing and fixing 1st quality Ceramic glazed wall tilesconforming to IS: 15622 (thickness to be specified by the manufacturer) minimum thickness 5mm of NITCO, SOMANY, ASIAN, KAJARIAor equivalent approved make in all colours, shades except burgundy, bottle green, black of size 300x200 in skirting and dados over 12 mm thick bed of cement mortar 1:3 (1 cement : 3coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete as per direction of Engineer-In-charge. In all floors and all heights .
62Ground Floor
63Providing and fixing 16mm thick Kota stone flooring (sample of Kota stone should be approved by EIC) for any locations where ever required in horizontal/vertical surfaces of required size of approved shade, colour and texture, with moulding edge etc. laid over 25mm thick bed of cement mortar 1:1 (1 cement : 1 coarse sand) with joints treated with white cement mixed with matching pigment, epoxy touch ups including rubbing, curing, moulding and polishing to give high gloss finish etc. complete as per direction of Engineer-In-Charge. In all floors and all heights.
64Ground Floor
65Providing & Applying priming coat with Waterbase wall primer of approved brand and manufacture onplaster/putty surface as per the instruction of Engineer-In-Charge at all elevations and all heights including all material & labour complete.
66Ground Floor
67Terrace Floor
68Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacturer,over the plastered wall surfaces to prepare the surface even and smooth as per the instruction of Engineer-In-Charge at all elevations including all material & labour complete.
69Ground Floor
70Terrace Floor
71Providing and applying to outside walls with two or more coats ofAnti-Fungal Weather coat water proofing paint including scaffolding and cleaning the surface before application of approved colour and manufacture as per specification, instruction of Engineer-In-charge at all elevations including all material labour complete.
72Ground Floor
73Terrace Floor
74Preparing surface and painting at all height with two or more coats of interior Plastic Emulsion "Royale Shyne" of Asian Paints or equivalent of approvedshade as per the instructions of the manufacturers; giving uniform shade etcin all heights of walls etc. including interiorwall primer & providing scaffolding, cleaning, curing and supply of all materials and labour complete as per drawing, design and direction of Architect/Engineer-In-Charge.
75Ground Floor
76Terrace Floor
77Providing & Painting with synthetic enamel paint of approved brand and manufacture to give an even shade as per the instruction of Engineer - In-Charge at all floors and all heights including all material & labour complete.
78Ground Floor
79Terrace Floor
80Supplying, fitting and fixing of Stainless steel of 304 grade in hand ralling using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm X 32mm X 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm X 32mm X 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, taxes, all materials, labour, T&P etc. required for the complete in all respect.
81Ground Floor
82Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well ramed, consolidated and grouted with fine sand and finishing the top smooth including shuttering at the edges, excavation and disposing of surplus earth with a lead of 100m.
83Providing and fixing 10-12 mm thick Teracotta Slope Tile for Slope roof, wall and similar locations where ever required in horizontal/vertical surfaces of required size of approved shade, colour and texture, with moulding edge & approved groove pattern etc. laid over 12mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand) with joints treated with white cement mixed with matching pigment, epoxy touch ups including rubbing, curing, moulding and polishing to give high gloss finish etc. complete as per direction of Engineer-in-charge. In all floors and all heights.
84INTERNAL ELETRIFICATION WORK
85INTERNAL PH WORK
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail