Border Security Force-BSF has published Tender For Repair And Maintenance Of Fire Alarm System Installed At Composite Hospital Bsf Srinagar Under Ftr Hq Bsf Kashmir. Submission Date for this Tender is 26-09-2023. Fire Alarm Systems Tenders in srinagar Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

39553986
Tender For Repair And Maintenance Of Fire Alarm System Installed At Composite Hospital Bsf Srinagar Under Ftr Hq Bsf Kashmir
Open Tender
Indian
Jammu And Kashmir
srinagar
26-09-2023

Tender Details

Repair And Maintenance Of Fire Alarm System Installed At Composite Hospital Bsf Srinagar Under Ftr Hq Bsf Kashmir

Key Value

Document Fees
Refer document
EMD
INR 11910.0 /-
Tender Value
INR 5.95 Lakhs /-

BOQ Items

Name of Work: Repair and Maintenance of Fire Alarm system installed at Composite Hospital BSF Srinagarunder FTR HQ BSF Kashmir.
Sl. No. Item Description
1Supplying, installation, testing & commissioning of smoke and Heat detector with built-in LED and mounting base complete with all connections ideal for applications where slow-burning or Smouldering fires likely as under specification or equivalant:- (a) Detection principle: Photo electric detection of light scattered in a forward direction by smoke particles,(b) Chamber Configuration: Horizontal opticle bench housing an infrared emitter and sensor arranged radially to detect forward scattered light. (c) Sampling frequency: Once every four seconds. (d) Alarm indicator : Integral indicator 360 degree visibility -10 C to 50 C. (e) Operating Tem Humidity : 0% to 95 % RH. (f) Effect of atmospheric pressure:None. (g)Effect of wind : None. (h) Vibration, impact & shock : EN54-7. (i) IP rating: IP23D
2Supplying, installation, testing & commissioning of manual call boxesof MS construction in surface/recess with stainless with glass and push button etc. as required required specification or equivalent :- (a) Supply Voltage : 17-35 V DC. (b) Digital Communications Protocol :Core Protocol, Discovery & XP95 compatible, 5-13V peak to peak. (c) Current consumption (max) :At 24 V 1Ma DC. (d)Quiescent :100 micro Amp (e) Alarm Current: 4mA. (f) Operating Temp :-40 deg C to 70 deg C. (g) Humidity :0 % to 95% RH (h) Vibration, impact and shock :EN 54-11 & EN 54-17. (i) IP rating : IP44
3Supplying, installation, testing & commissioning fire alarm sounderwith facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.
4Supplying, installation, testing & suitable for following zones, complete with visual indications for commissioning sector panel short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required.(A) 4-Zone (a) Operating Voltage : 230 V AC, (b) Internal Power Supply:Output Voltage +18.5 to +28.5 V DCOutput Current 1.8 Amps max,(c) Construction : Fire retardant, ABS plastic module enclosure, sealed to IP30,(d) Operating Temp :+5 deg C to 45 deg C, (d)Relative Humidity : 0 % to 95% RH,(e) Vibration, impact andshock : EN 54-11 & EN 54-17,(f)IP rating:IP44,(g) Detection circuit : 4, 2mAmp per circuit(typically>20 detector), (h) Digital input :22 configurable (class change alert, Evacuate Reset),(i) Digital input trigger : Extended closing contact, (j) Sounder output: 2 monitored outputs 0.5 Amps per circuit
5Supplying, installation, testing & commissioning of main control and indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colorwith louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc complete as required. 12 Zone panel for fire alarm system 250 Watt amplifier racks suitable for operation on 230V AC/24V DC supply conforming to IEC-268-3 complete with all accessories as required - 2 Nos.(one to act as standby) Battery charger trickle cum boost to take complete load of fire alarmwith all accessories including providing & fixing of 2 nos.12 volt, 60 AH each sealed maintenance free batteries - 1 set.
6Supplying & Drawing of 2 x 1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armoring & FRLS outer sheath complete as required.