Tender For Construction Of Bbmb Museum At Nangal Township, nangal-Punjab

Bhakra Beas Management Board-BBMB has published Tender For Construction Of Bbmb Museum At Nangal Township. Submission Date for this Tender is 04-12-2023. Building Work Tenders in nangal Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

39509259
Corrigendum : Tender For Construction Of Bbmb Museum At Nangal Township
Open Tender
Indian
Punjab
nangal
04-12-2023

Tender Details

Construction Of Bbmb Museum At Nangal Township

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 10-Oct-2023 Corrigendum 1 Date 19-10-2023
2 20-Oct-2023 Corrigendum 2 Date 01-11-2023
3 02-Nov-2023 Corrigendum 3 Date 20-11-2023
4 21-Nov-2023 Corrigendum 4 Date 22-11-2023
5 21-Nov-2023 CORRIGENDUM 4A Date 04-12-2023

Key Value

Document Fees
INR 5900 /-
EMD
INR 1614550.0 /-
Tender Value
INR 8.07 Crore /-

BOQ Items

Name of Work: Construction of BBMB Museum at Nangal Township.
Sl. No. Item Description
1CIVIL WORK ITEMS
2Excavation in Soil (any type) using Hydraulic Excavator CK 90 with hydraulic excavator of 0.9 cum bucket capacity including cutting, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, including all lifts and combined lead upto 30m. (CSR Item No. - 6.19)
3Cement concrete 1:4:8 With stone aggregate 40mm gauge mixing by mechanical means using concrete mixer volumetric type (CSR Item No. - 10.11 (b)(ii))
4First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth. (CSR Item No. - 11.5)
5115mm thick brick wall laid in cement mortar 1:4 without reinforcement in foundation and plinth. (CSR Item No. - 11.35)
6Damp proof course 4cm thick of cement concrete 1:2:4 with 2 coats of bitumen 20/30 penetration at 1.65 Kg per sqm laid hot and sanded (CSR Item No. - 10.26)
740 mm thick cement plaster DPC 1:3 with admixture of water proofing compound @ 1Kg/bag of cement (CSR Item No. - 15.51)
8RCC M-20 mechanically batch mixed using batch type concrete mixture as per IS:1791 andvibrated by needle vibrator but excludingsteel reinforcement centering and shuttering in foundation and plinth. (CSR Item No. - 10.15)
9RCC- M-25 mechanically batch mixed using batch type concrete mixture as per IS:1791 andvibrated by needle vibrator but excludingsteel reinforcement centering and shuttering in foundation and plinth. (CSR Item No. - 10.16)
10RCC- M-30 mechanically batch mixed using batch type concrete mixture as per IS:1791 andvibrated by needle vibrator but excludingsteel reinforcement centering and shuttering in foundation and plinth. (CSR Item No. - 10.17)
11RCC- M-35 mechanically batch mixed using batch type concrete mixture as per IS:1791 andvibrated by needle vibrator but excludingsteel reinforcement centering and shuttering in foundation and plinth. (CSR Item No. - 10.18)
12Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. (CSR Item No. - 10.20)
13Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure.in 1st story (upto 4 mtr height ). (CSR Item No. - 10.21)
14Reinforced cement concrete M-35 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure.in 1st story (upto 4 mtr height ). (CSR Item No. - 10.23)
15Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure in 1st story (4 mtr to 5 mtr height). (CSR Item No. - 10.20,10.49)
16Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure in 1st story ( 4 mtr to 5 mtr height ). (CSR Item No. - 10.21,10.49)
17Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure in 1st story ( 5 mtr to 6 mtr height ). (CSR Item No. - 10.21,10.49)
18Reinforced cement concrete M-35 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure in 1st story ( 4 mtr to 5 mtr height ). (CSR Item No. - 10.23,10.49)
19Reinforced cement concrete M-35 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure in 1st story ( 5 mtr to 6 mtr height ). (CSR Item No. - 10.23,10.49)
20Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure in second story (upto 4 mtr height ). (CSR Item No. - 10.20,10.48)
21Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructurein second story (upto 4 mtr height ). (CSR Item No. - 10.21,10.48)
22Reinforced cement concrete M-35 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. in second story (upto 4 mtr height ). (CSR Item No. - 10.23,10.48)
23Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure in second story (4 mtr to 5 Mtr height). (CSR Item No. - 10.20,10.48,10.49)
24RCC M-25 mechanically batch mixed using batch type concrete mixture as per IS:1791 andvibrated by needle vibrator but excludingsteel reinforcement centering and shuttering in super structure in second story (4 mtr to 5 Mtr height). (CSR Item No. - 10.21,10.49,10.48)
25RCC M-25 mechanically batch mixed using batch type concrete mixture as per IS:1791 andvibrated by needle vibrator but excludingsteel reinforcement centering and shuttering in super structure in second story (4 mtr to 5 Mtr height). (CSR Item No. - 10.21,10.49,10.48)
26RCC M-35 mechanically batch mixed using batch type concrete mixture as per IS:1791 andvibrated by needle vibrator but excludingsteel reinforcement centering and shuttering in super structure in second story(4 mtr to 5 Mtr height). (CSR Item No. - 10.23,10.49,10.48)
27RCC M-35 mechanically batch mixed using batch type concrete mixture as per IS:1791 andvibrated by needle vibrator but excludingsteel reinforcement centering and shuttering in super structure in second story(5 mtr to 6 Mtr height). (CSR Item No. - 10.23,10.49,10.48)
28RCC M-20 mechanically batch mixed using batch type concrete mixture as per IS:1791 andvibrated by needle vibrator but excludingsteel reinforcement centering and shuttering in super structure in 3rd story (upto 4 mtr height). (CSR Item No. - 10.20,10.48)
29RCC M-25 mechanically batch mixed using batch type concrete mixture as per IS:1791 andvibrated by needle vibrator but excludingsteel reinforcement centering and shuttering in super structure in 3rd story (upto 4 Mtr height). (CSR Item No. - 10.21,10.48)
30RCC M-35 mechanically batch mixed using batch type concrete mixture as per IS:1791 andvibrated by needle vibrator but excludingsteel reinforcement centering and shuttering in super structure in 3rd story (upto 4 Mtr height). (CSR Item No. - 10.23,10.48)
31RCC M-20 mechanically batch mixed using batch type concrete mixture as per IS:1791 andvibrated by needle vibrator but excludingsteel reinforcement centering and shuttering in super structure in 3rd story (4 to 5 Mtr height). (CSR Item No. - 10.20,10.49,10.48)
32RCC M-25 mechanically batch mixed using batch type concrete mixture as per IS:1791 andvibrated by needle vibrator but excludingsteel reinforcement centering and shuttering in super structure in 3rd story (4 to 5 Mtr height). (CSR Item No. - 10.21,10.49,10.48)
33RCC M-25 mechanically batch mixed using batch type concrete mixture as per IS:1791 andvibrated by needle vibrator but excludingsteel reinforcement centering and shuttering in super structure in 3rd story (5mtrto 6 Mtr height). (CSR Item No. - 10.21,10.49,10.48)
34RCC M-35 mechanically batch mixed using batch type concrete mixture as per IS:1791 andvibrated by needle vibrator but excludingsteel reinforcement centering and shuttering in super structure in 3rd story (4 to 5 Mtr height). (CSR Item No. - 10.23,10.49,10.48)
35RCC M-35 mechanically batch mixed using batch type concrete mixture as per IS:1791 andvibrated by needle vibrator but excludingsteel reinforcement centering and shuttering in super structure in 3rd story (5 to 6 Mtr height). (CSR Item No. - 10.23,10.49,10.48)
36RCC M-20 mechanically batch mixed using batch type concrete mixture as per IS:1791 andvibrated by needle vibrator but excludingsteel reinforcement centering and shuttering in super structure (i) In 3rd story (6 to 7 Mtr height) . (CSR Item No. - 10.20,10.49,10.48)
37RCC M-25 mechanically batch mixed using batch type concrete mixture as per IS:1791 andvibrated by needle vibrator but excludingsteel reinforcement centering and shuttering in super structure in 4th story (upto 4 Mtr height) (CSR Item No. - 10.21,10.48,)
38RCC M-25 mechanically batch mixed using batch type concrete mixture as per IS:1791 andvibrated by needle vibrator but excludingsteel reinforcement centering and shuttering in super structure where a single story exceeds 4 mtr. height (6 to 7 Mtr height). (CSR Item No. - 10.21,10.49)
39RCC M-25 mechanically batch mixed using batch type concrete mixture as per IS:1791 andvibrated by needle vibrator but excludingsteel reinforcement centering and shuttering in super structure where a single story exceeds 4 mtr. height (7 to 8 Mtr height). (CSR Item No. - 10.21,10.49)
40RCC M-35 mechanically batch mixed using batch type concrete mixture as per IS:1791 andvibrated by needle vibrator but excludingsteel reinforcement centering and shuttering in super structure where asingle story exceed 4 Mtr height (6 to 7 Mtr height). (CSR Item No. - 10.23,10.49)
41RCC M-35 mechanically batch mixed using batch type concrete mixture as per IS:1791 andvibrated by needle vibrator but excludingsteel reinforcement centering and shuttering in super structure where asingle story exceed 4 Mtr height (7 to 8 Mtr height). (CSR Item No. - 10.23,10.49)
42RCC M-25 mechanically batch mixed using batch type concrete mixture as per IS:1791 andvibrated by needle vibrator but excludingsteel reinforcement centering and shuttering in super structure where a single story exceed 4 Mtr height(8 to 9 Mtr height). (CSR Item No. - 10.22,10.49)
43RCC M-25 mechanically batch mixed using batch type concrete mixture as per IS:1791 andvibrated by needle vibrator but excludingsteel reinforcement centering and shuttering in super structure where a single story exceed 4 Mtr height(9 to 10 Mtr height). (CSR Item No. - 10.22,10.49)
44RCC M-35 mechanically batch mixed using batch type concrete mixture as per IS:1791 andvibrated by needle vibrator but excludingsteel reinforcement centering and shuttering in super structure where a single story Exceeds 4 Mtr height(8 to 9 Mtr height). (CSR Item No. - 10.23,10.49)
45RCC M-35 mechanically batch mixed using batch type concrete mixture as per IS:1791 andvibrated by needle vibrator but excludingsteel reinforcement centering and shuttering in super structure where a single story Exceeds 4 Mtr height(9 to 10 Mtr height). (CSR Item No. - 10.23,10.49)
46RCC M-20 mechanically batch mixed using batch type concrete mixture as per IS:1791 andvibrated by needle vibrator but excludingsteel reinforcement centering and shuttering in super structure where a single story exceed 4 Mtr height(10 to 11 Mtr height). (CSR Item No. - 10.20,10.49)
47RCC M-25 mechanically batch mixed using batch type concrete mixture as per IS:1791 andvibrated by needle vibrator but excludingsteel reinforcement centering and shuttering in super structure where a single story exceed 4 Mtr height(10 to 11 Mtr height). (CSR Item No. - 10.21,10.49)
48RCC M-25 mechanically batch mixed using batch type concrete mixture as per IS:1791 andvibrated by needle vibrator but excludingsteel reinforcement centering and shuttering in super structure where a single story exceed 4 Mtr height(11 to 12Mtr height). (CSR Item No. - 10.21,10.49)
49RCC M-35 mechanically batch mixed using batch type concrete mixture as per IS:1791 andvibrated by needle vibrator but excludingsteel reinforcement centering and shuttering in super structure where a single story exceeds 4 Mtr height(10 to 11Mtr height). (CSR Item No. - 10.23,10.49)
50Shuttring for faces of concrete foundations and foundation beams and plinth beam (vertical or battering). (CSR Item No. - 9.1)
51Centring and shuttring for faces of walls, partitions, retaning walls and the like (vertical or battering including attached plastered buttersses etc. In first story (upto 4 mtr height). (CSR Item No. - 9.2)
52Centring and shuttring for faces of walls, partitions, retaning walls and the like (vertical or battering including attached plastered buttersses etc. In first story (4 to 5 mtr height). (CSR Item No. - 9.2,9.16)
53Centring and shuttring for faces of walls, partitions, retaning walls and the like (vertical or battering including attached plastered buttersses etc. In first story (5 to 6 mtr height). (CSR Item No. - 9.2,9.16)
54Centring and shuttring for faces of walls, partitions, retaning walls and the like (vertical or battering including attached plastered buttersses etc. In 2nd story (upto 4 mtr height). (CSR Item No. - 9.2,9.15,)
55Centering and shuttring for faces of walls, partitions, retaning walls and the like (vertical or battering including attached plastered buttersses etc. In 2nd story (4 to 5 mtr height). (CSR Item No. - 9.2,9.15,9.16)
56Centering and shuttring for faces of walls, partitions, retaning walls and the like (vertical or battering including attached plastered buttersses etc. In 2nd story (5 to 6 mtr height). (CSR Item No. - 9.2,9.15,9.16)
57Centring and shuttring for faces of walls, partitions, retaning walls and the like (vertical or battering including attached plastered buttersses etc. In 3rd story (upto 4 mtr height). (CSR Item No. - 9.2,9.15,)
58Centring and shuttring for faces of walls, partitions, retaning walls and the like (vertical or battering including attached plastered buttersses etc. In 3rd story (4 to 5 mtr height). (CSR Item No. - 9.2,9.15,9.16)
59Centring and shuttring for faces of walls, partitions, retaning walls and the like (vertical or battering including attached plastered buttersses etc. In 3rd story (5 to 6 mtr height). (CSR Item No. - 9.2,9.15,9.16)
60Centring and shuttring for columns (Squares or Rectangular or poly gonal in plan) in first story (upto 4 mtr height). (CSR Item No. - 9.4)
61Centring and shuttring for columns (Squares or Rectangular or poly gonal in plan) in first story (4 to 5 mtr height.) (CSR Item No. - 9.4,9.16)
62Centring and shuttring for columns (Squares or Rectangular or poly gonal in plan) in first story (5 to 6 mtr height.) (CSR Item No. - 9.4,9.16)
63Centring and shuttring for columns (Squares or Rectangular or poly gonal in plan) in 2nd story (upto 4 mtr height). (CSR Item No. - 9.4,9.15)
64Centring and shuttring for columns (Squares or Rectangular or poly gonal in plan) in 2nd story (4 to 5 mtr height). (CSR Item No. - 9.4,9.15,9.16)
65Centring and shuttring for columns (Squares or Rectangular or poly gonal in plan) in 2nd story (5 to 6 mtr height). (CSR Item No. - 9.4,9.15,9.16)
66Centring and shuttring for columns (Squares or Rectangular or poly gonal in plan) in 3rd story (upto 4 mtr height). (CSR Item No. - 9.4,9.15)
67Centring and shuttring for columns (Squares or Rectangular or poly gonal in plan) in 3rd story (4 to 5 mtr height). (CSR Item No. - 9.4,9.15,9.16)
68Centring and shuttring for columns (Squares or Rectangular or poly gonal in plan) in 3rd story (5 to 6 mtr height). (CSR Item No. - 9.4,9.15,9.16)
69Centring and shuttring for columns (Circular or curved in plain) in first story (upto 4 mtr height). (CSR Item No. - 9.5)
70Centring and shuttring for columns (Circular or curved in plain) in first story (4 to 5 mtr height). (CSR Item No. - 9.5,9.16)
71Centring and shuttring for columns (Circular or curved in plain) in first story (5 to 6 mtr height). (CSR Item No. - 9.5,9.16)
72Centring and shuttring for columns (Circular or curved in plain) in 2nd story (upto 4 mtr height). (CSR Item No. - 9.5,9.15)
73Centring and shuttring for columns (Circular or curved in plain) in 2nd story (4 to 5 mtr height). (CSR Item No. - 9.5,9.15,9.16)
74Centring and shuttring for columns (Circular or curved in plain) in 2nd story (5 to 6 mtr height). (CSR Item No. - 9.5,9.15,9.16)
75Centring and shuttring for columns (Circular or curved in plain) in 3rd story (upto 4 mtr height). (CSR Item No. - 9.5,9.15)
76Centring and shuttring for columns (Circular or curved in plain) in 3rd story (4 to 5 mtr height). (CSR Item No. - 9.5,9.15,9.16)
77Centring and shuttring for columns (Circular or curved in plain) in 3rd story (5 to 6 mtr height). (CSR Item No. - 9.5,9.15,9.16)
78Centring and shuttring for columns (Circular or curved in plain) where a single story exceed 4 mtr. Height (6 to 7 mtr height). (CSR Item No. - 9.5,9.16)
79Centring and shuttring for columns (Circular or curved in plain) where a single story exceed 4 mtr. Height (7 to 8 mtr height). (CSR Item No. - 9.5,9.16)
80Centring and shuttring for columns (Circular or curved in plain) where a single story exceed 4 mtr. Height (8 to 9 mtr height). (CSR Item No. - 9.5,9.16)
81Centring and shuttring for columns (Circular or curved in plain) where a single story exceed 4 mtr. Height (9 to 10 mtr height). (CSR Item No. - 9.5,9.16)
82Centring and shuttring for columns (Circular or curved in plain) where a single story exceed 4 mtr. Height (10 to 11 mtr height). (CSR Item No. - 9.5,9.16)
83Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels in first story (upto 4 mtr height). (CSR Item No. - 9.6)
84Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels in first story (4 to 5 mtr height). (CSR Item No. - 9.6,9.16)
85Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels in first story (5 to 6 mtr height). (CSR Item No. - 9.6,9.16)
86Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels in second story (upto 4 mtr height). (CSR Item No. - 9.6,9.15)
87Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels in second story (4 to 5 mtr height). (CSR Item No. - 9.6,9.15. 9.16)
88Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels in 3rd story (upto 4 mtr height). (CSR Item No. - 9.6,9.15,)
89Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels in 3rd story (4 to 5 mtr height). (CSR Item No. - 9.6,9.15,9.16)
90Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels in 4th story (upto 4 mtr height). (CSR Item No. - 9.6,9.15)
91Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels where a single story exceeds 4 mtr height (6 to 7 mtr height). (CSR Item No. - 9.6,9.16)
92Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels where a single story exceeds 4 mtr height (7 to 8 mtr height). (CSR Item No. - 9.6,9.16)
93Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels where a single story exceeds 4 mtr height (8 to 9 mtr height). (CSR Item No. - 9.6,9.16)
94Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels where a single story exceeds 4 mtr height (9 to 10 mtr height). (CSR Item No. - 9.6,9.16)
95Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels where a single story exceeds 4 mtr height (10 to 11 mtr height). (CSR Item No. - 9.6,9.16)
96Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels where a single story exceeds 4 mtr height (11 to 12 mtr height). (CSR Item No. - 9.6,9.16)
97Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. in first story (upto 4 mtr height). (CSR Item No. - 9.8)
98Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. in first story (4 to 5 mtr height). (CSR Item No. - 9.8,9.16)
99Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. in second story (upto 4 mtr height). (CSR Item No. - 9.8,9.15)
100Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. in second story (4 to 5 mtr height). (CSR Item No. - 9.8,9.15,9.16)
101Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. in 3rd story (upto 4 mtr height). (CSR Item No. - 9.8,9.15)
102Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. in 3rd story (4 to 5 mtr height). (CSR Item No. - 9.8,9.15,9.16)
103Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. in 4th story (upto 4 mtr height). (CSR Item No. - 9.8,9.15)
104Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. where a single story exceeds 4 mtr height (10 to 11 mtr height). (CSR Item No. - 9.8,9.16)
105Centring and shuttring for carbels, parapet, fascias and other similar items including edges in first story (upto 4 mtr height). (CSR Item No. - 9.10)
106Centring and shuttring for carbels, parapet, fascias and other similar items including edges in second story (4 to 5 mtr height). (CSR Item No. - 9.10,9.15,9.16)
107Centring and shuttring for carbels, parapet, fascias and other similar items including edges in 3rd story (4 to 5 mtr height). (CSR Item No. - 9.10,9.15,9.16)
108Centring and shuttring for carbels, parapet, fascias and other similar items including edges in 4th story (upto 4 mtr height). (CSR Item No. - 9.10,9.15,)
109Centring and shuttring for carbels, parapet, fascias and other similar items including edges where a single story exceeds 4 mtr height (10 to 11 mtr height). (CSR Item No. - 9.10,9.16)
110Cold twisted deformed (Ribbed/ Tor Steel Bar) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete in first story. (CSR Item No. - 18.18)
111Cold twisted deformed (Ribbed/ Tor Steel Bar) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete in second story. (CSR Item No. - 18.18,18.35)
112Cold twisted deformed (Ribbed/ Tor Steel Bar) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete in 3rd story. (CSR Item No. - 18.18,18.35)
113Cold twisted deformed (Ribbed/ Tor Steel Bar) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete in 4th story. (CSR Item No. - 18.18,18.35)
114First class burnt brick work laid in cement sand mortar 1:5 in super structure in first story (upto 4 mtrs height). (CSR Item No. - 11.6)
115First class burnt brick work laid in cement sand mortar 1:5 in super structure in first story (4 to 6mtrs height). (CSR Item No. - 11.6,11.29(b))
116First class burnt brick work laid in cement sand mortar 1:5 in super structure insecond story (upto 4 mtr height). (CSR Item No. - 11.6,,11.29(a))
117First class burnt brick work laid in cement sand mortar 1:5 in super structure in second story (4 to 6 mtr height). (CSR Item No. - 11.6,11.29(b),11.29(a))
118First class burnt brick work laid in cement sand mortar 1:5 in super structure in 3rd story (upto 4 mtrs height). (CSR Item No. - 11.6,11.29(a))
119First class burnt brick work laid in cement sand mortar 1:5 in super structure in 3rd story(4 to 6 mtr height). (CSR Item No. - 11.6,11.29(b),11.29(a))
120First class burnt brick work laid in cement sand mortar 1:5 in Super sturcture in 4th story (upto 4 mtr height). (CSR Item No. - 11.6,11.29(a))
121115mm thick brick wall in cement sand mortar 1:4 without reinforcement in superstructure in first story (upto 4 mtr height). (CSR Item No. - 11.36)
122115mm thick brick wall in cement sand mortar 1:4 without reinforcement in superstructure in first story (4 to 5 mtr height). (CSR Item No. - 11.36,11.29(b))
123115mm thick brick wall in cement sand mortar 1:4 without reinforcement in superstructure in 2nd story (upto 4 mtr height). (CSR Item No. - 11.34,11.29(b),)
124115mm thick brick wall in cement sand mortar 1:4 without reinforcement in superstructure in 2nd story (4 to 6 mtr height). (CSR Item No. - 11.36,11.29(b),11.29(a))
125115mm thick brick wall with every fourth course reinforced with hoop iron laid in 1:4 cement sand mortar in super structure in 3rd story (upto 4 mtr height). (CSR Item No. - 11.34,11.29(a))
126115mm thick brick wall in cement sand mortar 1:4 without reinforcement in superstructure in 3rd story (4 to 6 mtr height). (CSR Item No. - 11.36,11.29 (b),11.29 (a))
127Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40 mm gauge and 100mm fine sand filling (Using mechnical mixer for mixing of material). (CSR Item No. - 14.3)
128Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps in first story (CSR Item No. - 14.88)
129Providing and laying vitrified floor tiles of different sizes in light colour shades made using Double Charge technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Design is homogenous throughout the tile body ). Size 1000x1000 mm (CSR Item No. - 14.113 ( c))
130Black Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps in first story. (CSR Item No. - 14.87)
131Black Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps in second story. (CSR Item No. - 14.87(Note iv))
132Black Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps in 3rd story (CSR Item No. - 14.87(Note iv))
133Black Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps in 4th story. (CSR Item No. - 14.87(Note iii))
134Marble stone flooring with 12-15 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : Makrana, Doongri, Adanga viened and chack Doongri with grey stretches. (b) Slabs sizes above 0.50 sqm (CSR Item No. - 14.74(i) b)
135Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 300 x 600 mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete in 1st floor. (CSR Item No. - 14.128)
136Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 300 x 600 mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete in IInd floor. (CSR Item No. - 14.128 & note (iv))
137Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 300 x 600 mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete in 3rd story. (CSR Item No. - 14.128(Note iv))
138Screed of 50mm thick cement concrete 1:8:16 with stone aggregateto be laid below the topping in 2nd story (using mechnical mixer for mixing of material). (CSR Item No. - 14.11(Note iv))
139Screed of 50mm thick cement concrete 1:8:16 with stone aggregate to be laid below the topping in 3rd story (using mechnical mixer for mixing of material). (CSR Item No. - 14.11(Note iv))
140Conglomerate floor 40mm thick cement concrete topping 1:2:4 in 3rd story (using mechnical mixer for mixing of material). (CSR Item No. - 14.6(Note iv))
141Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16. (CSR Item No. - 13.45)
142Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. (CSR Item No. - 13.55)
143Providing and fixing on wall face unplasticised Rigid PVC rain water pipes Single socketed (working pressure 4 kgf / cm²) conforming to IS : 4985, including fixing with ms clamps i)U-PVC pipes (working pressure 4 kgf. / sqcm)pipe 110 mm dia. (CSR Item No. - 13.74(a) (i))
144Providing and fixing 110 mm diaU.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. UPVC 110 mm bend (CSR Item No. - 13.75(a))
145Terracing consiting of mavhine made hollow clay tiles 80mm thick (smooth surface) confirming to IS: 3951(Part-I)-2009 laid over 25 mm mud plaster 7.5 cm mud filling on another laver of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg/sqm top of RCC slab including grouting with cement sand mortar 1:4having 10mm wide joints spacing on all sides of tiles and top surface to be left clean complete as per specification (laying shall be done as per PWD specifications). (CSR Item No. - 13.13(iii))
146Providing and fixing thermal insulation of ceiling (under deck insulation) with Resin Bonded Fibre glass wool conforming to IS : 8183 density 24kg/m3, 50mm thick, wrapped in 200 G Virgin Polythene bags fixed to ceiling with metallic cleats (50x50x3mm) @ 60 cm and wire mesh of 12.5mm x 24g wire and mesh, for top most ceiling of building. (CSR Item No. - 13.7)
147Plastering on underside of ceiling 10 mm thick cement plaster 1:3 in 1st story (CSR Item No. - 15.43)
148Plastering on underside of ceiling 10 mm thick cement plaster 1:3 in 2nd story (CSR Item No. - 15.43& 15.84)
149Plastering on underside of ceiling 10 mm thick cement plaster 1:3 in 3rd story (CSR Item No. - 15.43 & 15.84)
150Plastering on underside of ceiling 10 mm thick cement plaster 1:3 in 4th story (CSR Item No. - 15.43 & 15.84)
15112.5mm thick cement plaster 1:5 1st Story. (CSR Item No. - 15.10)
15212.5mm thick cement plaster 1:5 2ndStory. (CSR Item No. - 15.10 &15.84)
15312.5mm thick cement plaster 1:5 3rd Story. (CSR Item No. - 15.10 & 15.84)
15412.5mm thick cement plaster 1:54th Story. (CSR Item No. - 15.10& 15.84)
15520mm thick cement plaster 1:5 in two coat work 1st Story. (CSR Item No. - 15.21)
15620mm thick cement plaster 1:5 in two coat work 2nd Story. (CSR Item No. - 15.21 & 15.84)
15720mm thick cement plaster 1:5 in two coat work 3rd Story. (CSR Item No. - 15.21 & 15.84)
15820mm thick cement plaster 1:5 in two coat work 4th.Story. (CSR Item No. - 15.21 & 15.84)
159Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two coats to get required finish in 1st story. (CSR Item No. - 16.65)
160Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two coats to get required finish in 2nd story. (CSR Item No. - 16.65)
161Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two coats to get required finish in 3rd story. (CSR Item No. - 16.65)
162Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two coats to get required finish in 4th story. (CSR Item No. - 16.65)
163Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade in 1st story. (CSR Item No. - 16.10)
164Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade in 2nd story. (CSR Item No. - 16.10)
165Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade in 3rd story. (CSR Item No. - 16.10)
166Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade in 4th story. (CSR Item No. - 16.11)
167Finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm (CSR Item No. - 16.59)
168Structural steel work in angles, tees and flats, riveted or welded including cutting fixing all gusset plates, bolts, nuts, rivets, welding rod, etc. with hoisting and erecting in position :-(a) For roof trusses, well curbs, plates and trussed girders, etc. of any span for buildings and bridges more than 15 m up to 30 m span. (CSR Item No. - 18.3(a))
169Providing & fixing 16 gauge stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainless steel pipe, Balusters of 40mm dia Stainless steel pipe and guard 3 Nos of 15mm dia Stainless Steel pipe complete in all respect. (CSR Item No. - 18.39)
170Earth filling (a) (I) Earth filling gunder floors with surplus ordinary soil or containing gravel or kankar upto 40% excavated from foundation and taken only from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres (CSR Item No. - 6.8 (a) (i))
171Providing and applying Anti Termite Treatment using pre constructional chemical treatment measures as per IS - 6313 - 2001 ( Part 2 ) & using Chemical containg chloropyrifos systemic insecticide diluted to manufacturer"s specifications (i) In foundation pits, by treating the bottom & sides upto height of 300mm by uniformly spraying solution @ 5 Litre / Sqm (ii) In the refill earth on both sides of all built up walls @ 7.5 Litre / Running meter ( width - 300 mm, depth - 450 mm ) (iii) Before laying the floor, by uniformly sprinkling the top surface of the consolidated earth within the outer perimeter @ 5 Litre solution per Sqm. (CSR Item No. - 14.131)
172Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc (CSR Item No. - 16.16)
173Painting two coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade (CSR Item No. - 16.17)
174Cost of Aluminium fittings complete for doors,windows such as tower bolts, handless and screw etc. for these fittings (Excluding sliding bolt)(i) For shutter area above 0.50 sqm (CSR Item No. - 17.23(ii))
175Factory manufactured solied flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II IS-2202-1 Part-I ( 1999), ( c) Decorative with teak facing on both sides edges lipped with teak with laminated core,35mm thick. (CSR Item No. - 17.27( c) (iv))
176Chowkats of commercial hard wood such as Hollock confirming to ISI specification no 1003 m kiln seasoned of doors and windows including iron hold fasts, corner straps cleats, stops, bolts for hold fasts etc, complete fixed in position B) Single rebate(60x100mm) (CSR Item No. - 17.15(ii) (B))
177Providing and fixing aluminium sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete (b) 250mmx16mm (CSR Item No. - 17.49(b))
178Applying priming coat with metal primer on new steel or iron work includng preperation of surface. (CSR Item No. - 16.20)
179Painting two or more coats excluding priming coat with synthetic paint for metallic surfaces in all shades on steel or iron work (CSR Item No. - 16.17)
180Providing and fixing ( PPGL) precoated painted galvalume sheet roofing (size, shape and pitch of corrugation as approved by Engineer-in-charge) The end rib shall have anti cappillary groove and return leg. The steel sheet must be having yield strength of 550 MPa ( Fy= 550 MPa) metallic coated with Zinc- Aluminium alloy ( i.e. 55% Al, 43.4%Zinc, 1.6% Si-Zincalume) AZ150 ( Min. 150 bm/mm2 total on both sides), pre painted with super Durable Polyster XRW quality paint includes inorganic infrared reflective pigment. The sheet confirms to general requirement of AS/NZS 2728 type 4/ IS 15965 class 3 durability and gloss value of 25% -40%. should be supplied in single length upto 12 metre or as desired by Engineer-in charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. b) 0.60 mm (+ 0.05 %) thick (CSR Item No. - 13.27 (iii) (b))
181NON SCHEDULE ITEMS (Civil Works)
182Providing and fixing POP false ceiling at all height including providing and fixing of frame work made of special sections of 75 mm GI channel main member of 22 gauge and cross channel of 24 gauge at 450 mm c/c spacing both sides with wire mesh having weight of 10 kgs per 10 sqm fixed to the channels and rcc roof with screws / washers and fasteners as per design and drawing provided by the client complete in all respects. ( The surface area of the ceiling shall be measured for payment.) (MR)
183providing & fixing structural glazing with toughened glass (12mm clear polish flat tempered) including necessary spider fitting such as DORMA single arm/two arm/four arm fin spider, articulated bolts per upto 15.52 mm glass, fasteners 12mm x 4"", droma glass suspension bracket etc. as per Architectural design in elevation upto all heights complete in all respects to the approval/ satisfaction of Engineer-in-charge. (AOR)
184providing & fixing structural glazing with 17.52mm toughened laminated glass {(layer 1; toughened glass 8mm clear polish flat tempered)+(flat laminated with 1.52mm clear PVB)+(layer 2: toughened glass polish flat tempered)} including necessary spider fitting such as DORMA single arm/two arm/four arm fin spider, articulated boltsfasteners 12mm x 4"", droma glass suspension bracket etc. as per Architectural design in elevation upto all heights complete in all respects to the approval/ satisfaction of Engineer-in-charge. (AOR)
185Providing and fixing glass railing with toughened glass (12mm clear polish flat tempered) including necessary fitting for fixing as per architectural design upto all heightscomplete in all respect to the approval/satisfaction of Engineer-in-charge. (AOR)
186providing & fixing structural glazing with 22.28mm toughened laminated glass {(layer 1; toughened glass 10mm clear polish flat tempered)+(flat laminated with 1.52mm clear sentry+0.76mm clear sentry) +(layer 2: toughened glass 10mm clear polish flat tempered)} including necessary fittings for fixing . as per Architectural design upto all heights complete in all respects to the approval/ satisfaction of Engineer-in-charge. (AOR)
187Providing and Fixing Rockfon Texture Square edge tiles in Ceiling of size 1195x595x15 mm thickwith combination of 12mm thick gypsum board in lighting and AC grill bands. The subtext tiles will comprise of NRC 0.95 base panel with 160 Kg/m3 and humidity resistance of 90% RH as per ISO-4611,ASTM C-165 ,ASTM C-303 , ASTM C-1104 and light reflectance upto 85% with Leed points Green Performance certified, and Thermal conductivity K=0.082 W/Mk with sag resistance with normal edge profile. Rockfone Texture 15mm for Ceiling tilemeet the stringent fire test required having Class ‘A’ rating for Flame Ignitability test as per ASTM-E-84, with complete framework ofRockfon. (AOR)
188Water Supply
189Providing and fixing in position Chinaware extended wall mounted E. W.C. type suite (size 66 x 46 x 77.5 cm ) with P trap or S trap of approved make (to the approval of the Engineer-in-charge) with or without 10 ltr. chinaware matching flushing cistern and seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. (b) Chinaware wall mounted E.W.C without cistern including seatcover complete in all respect. (CSR Item No. - 30.05 (b))
190Providing and fixing in position concealed cistern including flusing plate of approval make (To the approval Engineer-in-charge) (CSR Item No. - 30.6 ( c ))
191Providing and fixing in position vitreous Chinaware white Senso urinal size 37 x 39 x 61 cm of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass Urinal waste Coupling dome type 32mm outer length 75 mm complete in all respect. (CSR Item No. - 30.17 (a))
192Vitreous white Chinaware Partition (ii) Large partition size 75 x 16.5 x 36.5 cm (CSR Item No. -30.21(B) ii)
193Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect. Size 630mm x 500mm (above counter oval) (CSR Item No. - 30.32 (viii))
194Providing and fixing in position 32 mm dia G.I waste pipe embedded in wall upto floor level including cost of fittings complete as required by the Engineer - in - charge (CSR Item No. - 30.42 (a))
195roviding and fixing in position CP brass Bottle trap 32 mm dia with 40 mm seal of approved make ( to the approval of Engineer - in - charge) in all respect (CSR Item No. - 30.44 (A))
196Providing and fixing in postion mirror of superior glass size 1500 mm x 600 mm or any other required size ( of approved quality) and of required shape and size with high quality polystyrene moulding frame of 40 to 50 mm size ( of approved quality and shape ) with 4 mm thick hardboard backing fixed in with rawl plugs 50 mm, C.P. brass screws and washers complete in all respect. (CSR Item No. - 30.62 (b))
197Providing and fixing liquid soap container of approved make (to the approval of Engineer-in-charge) complete in all respectCP brass liquid soap container (CSR Item No. - 30.67 (a))
198Providing and fixing Stainless steel health faucet complete in all respect. (CSR Item No. - 30.24)
199Providing & Fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-In-Charge) complete in all respect. PVC tube connection of size 15 mm x 450 mm with C.P. Brass nut (CSR Item No. - 30.72 (b))
200Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect. C.P. brass Bib cock long nose/ long body foam flow without flange (CSR Item No. - 30.65A (i))
201Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect. C.P.brass 15mm Angle valve without flange (CSR Item No. - 30.66 ( c ))
202Providing and fixing in position vitreous Chinaware white laboratory sinks of approved make (to the approval of Engineerin- charge) consisting of a pair of brackets, C.P. brass waste 40mm complete in all respect. Size 470mmx370mmx180mm (CSR Item No. - 30.55 (b))
203Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects. (a)110mm o/d pipe (CSR Item No. - 29.43 (a))
204Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects(b) For 125mm internal diameter pipes (CSR Item No. - 29.43 (b))
205Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects(c) 160mm o/d pipe (CSR Item No. - 29.43 (c))
206Providing and fixing in position paper holders of approved make (to the approval of Engineer-in-Charge) fixed into wall with CP Brass screws complete in all respects (a) CP brass toilet paper holders (CSR Item No. - 30.57 (a))
207Providing and fixing towel rails ring of approved make (to the approval of Engineer-in-Charge) fixed in with rawl plugs embedded in walls with brass screws complete in all respects.(a) CP brass towel rails size 15mm dia 600mm long (CSR Item No. - 30.58 (a))
208Providing and fixing in position CP brass soap dish of approved make (to the approval of engineer-in-charge) fixed into walls with rawl plugs and CP brass screws complete in all respects. (CSR Item No. - 30.60)
209Providing and fixing in position UPVC special for soil waste vent or anti siphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining.A)110mm o/d pipes i) Single Tee With Door (CSR Item No. - 30.81 (iii)B (ii))
210Providing and fixing in position UPVC special for soil waste vent or anti siphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining.A)110mm o/d pipes(i)Single Tee (CSR Item No. - 30.81 (iii) B (iii))
211Providing and fixing in position UPVC special for soil waste vent or anti siphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining.A)110mm o/d pipes (ii) Door Elbow 90 Degree (All side socketed) (CSR Item No. - 30.81 (iii) B (iv))
212Providing and fixing in position UPVC special for soil waste vent or anti siphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining.A)110mm o/d pipes (iii) Elbow 90 Degree (All side socketed) (CSR Item No. - 30.81 (iii) B (v))
213Providing and fixing in position UPVC special for soil waste vent or anti siphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining.A)110mm o/d pipes (iv)Vent Cowls (CSR Item No. - 30.81 (iii) B (vi))
214Providing and fixing in position UPVC special for soil waste vent or anti siphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining.A)110mm o/d pipes (v) P Trap/Floor Trap 110mm x 75mm (CSR Item No. - 30.81 (iii) B(x))
215Providing and fixing in position UPVC special for soil waste vent or anti siphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining.A)110mm o/d pipes (vi) Nahani trap without jali 110mmx75mm (CSR Item No. - 30.81 (iii) ( c)(xix))
216Providing and fixing in position UPVC special for soil waste vent or anti siphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining.( b) For 90mm o/d pipes (i) Single tee with Door (CSR Item No. - 30.81 (iii) C (ii))
217Providing and fixing in position UPVC special for soil waste vent or anti siphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining.( b) For 90mm o/d pipes (ii) Single tee (CSR Item No. - 30.81 (iii) C (iii))
218Providing and fixing in position SWR UPVC special for soil waste vent or anti siphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining.( b) For 90mm o/d pipes (iii) Door elbow 90 degree (all side socket) (CSR Item No. - 30.81 (iii) C (iv))
219(Providing and fixing in position UPVC special for soil waste vent or anti siphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining.( b) For 90mm o/d pipesiv) Elbow 90 degree (all side socket) (CSR Item No. - 30.81 (ii) C (v))
220Providing and fixing in position UPVC special for soil waste vent or anti siphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining.( b) For 90mm o/d pipes (v) Vent Cowls (CSR Item No. - 30.81 (iii) C (vi))
221Providing and fixing in position automatic brass ball cock in tanks.(B) Brass ball cock with rod and plastic ball(ii) 20 mm i/d (CSR Item No. - 30.96 (B) (ii))
222Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm. (a)100mm internal Diametre H.C.I. gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm (CSR Item No. - 30.99 (b))
223Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design. A) 600mm x 900mm inside with 455mm x 455mm cover and frame light duty double seal (CSR Item No. - 29.60 ( c))
224Extra for every 0.30 metre depth of inspection chamber.C ) 600mm x 900mm inside (CSR Item No. - 29.61 ( c))
225Excavation manually in trenches for Pipe Lines with straight or open cutting in streets and lanes in built up area where width of streets / lanes from wall to wall is less than 3m including trimming and dressing sides leveling of beds of trenches to correct grade, cutting joint holes, refilling consolidation, watering, including the cost of dewatering of rain water, diversion for traffic, night signles. Providing and fixing cauction boards, watching, fencing etc. and removal of surplus soil from the site upto 15m distance complete in all respects.(a) Earth work upto 1.5 m Depth(i) All classes of soil expect rocky. (CSR Item No. - 28.1 (a) (i))
226Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes (as per IS:15801-2008) SDR 7.4 U V stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings i/c fixing the pipe with clamps at 1.00 m spacing includingtesting of pipes complete as per direction of Engineer in Charge. (Concealed work :- including cutting chases and making good the walls etc.)(a) PN - 16 Pipe, 16 mm OD (CSR Item No. - 28.39 (A) (a))
227Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes (as per IS:15801-2008) SDR 7.4 U V stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings i/c fixing the pipe with clamps at 1.00 m spacing includingtesting of pipes complete as per direction of Engineer in Charge. (Concealed work :- including cutting chases and making good the walls etc.) (b) PN - 16 Pipe, 20 mm OD (CSR Item No. - 28.39 (A) (b))
228Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes (as per IS:15801-2008) SDR 7.4 U V stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings i/c fixing the pipe with clamps at 1.00 m spacing includingtesting of pipes complete as per direction of Engineer in Charge. (Concealed work :- including cutting chases and making good the walls etc.) (c) PN - 16 Pipe, 25 mm OD (CSR Item No. - 28.39 (A) (c))
229Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes (as per IS:15801-2008) SDR 7.4 U V stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings i/c fixing the pipe with clamps at 1.00 m spacing includingtesting of pipes complete as per direction of Engineer in Charge. (Concealed work :- including cutting chases and making good the walls etc.) (d) PN - 16 Pipe, 40 mm OD (CSR Item No. - 28.39 (A) (e))
230Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes (as per IS:15801-2008) SDR 7.4 U V stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings i/c trenching , refilling & testing of joints complete as per direction of Engineer in Charge. Internal works:- Exposed on wall (f) PN - 16 Pipe, 50mm OD (CSR Item No. - 28.39 (B) (f))
231Providing and fixing in postion S.S grating with frame of approved make (as approved by the Engineer-in-charge) complete in all respect (CSR Item No. - 30.80)
232Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer - in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. (i) Triple Layer Tanks (CSR Item No. - 30.97A (i))
233Providing and fixing in position GI Tank nipple of approved make (to the approval of the Engineer-in-charge) in PVC water storage tanks complete in all respect (b) GI tank nipple 20 mm i/d (CSR Item No. - 30.98 (b))
234Providing and fixing in position GI Tank nipple of approved make (to the approval of the Engineer-in-charge) in PVC water storage tanks complete in all respect (f) GI tank nipple 50 mm i/d (CSR Item No. - 30.98 (f))
235Providing ,fixing and jointing brass ball valves screwed with SS/BRASS ball and spindle and teflon seats on GI pipe lins including all carrage complete. (b) 20 mm i/d brass ball valve (CSR Item No. - 28.44 (b))
236Providing ISI marked G.M ferrule as per IS:2692 drilling and tapping cast Iron pipe lines of all diameters and screwing in ferrule and connections complete in all respects. (c) 20 mm i/d ferrule heavy duty (CSR Item No. - 28.34 (c))
237Fire Hydrant & Fire Alarm System
238Providing & Fixing of M.S. Pipe of medium grade as per IS: 1239, including all accessories like: Tees, Flanges, Bends, Reducer, Nut Bolt, Gas Cut etc. Excavation all types of earth and painting with first quality enamel paint on pipe 100 MM Dia (NS)
239Providing & Fixing of M.S. Pipe of medium grade as per IS: 1239, including all accessories like: Tees, Flanges, Bends, Reducer, Nut Bolt, Gas Cut etc. Excavation all types of earth and painting with first quality enamel paint on pipe 80 MM Dia (NS)
240Providing & Fixing of M.S. Pipe of medium grade as per IS: 1239, including all accessories like: Tees, Flanges, Bends, Reducer, Nut Bolt, Gas Cut etc. Excavation all types of earth and painting with first quality enamel paint on pipe 65 MM Dia (NS)
241Providing & Fixing of M.S. Pipe of medium grade as per IS: 1239, including all accessories like: Tees, Flanges, Bends, Reducer, Nut Bolt, Gas Cut etc. Excavation all types of earth and painting with first quality enamel paint on pipe 50 MM Dia (NS)
242Providing & Fixing of M.S. Pipe of medium grade as per IS: 1239, including all accessories like: Tees, Flanges, Bends, Reducer, Nut Bolt, Gas Cut etc. Excavation all types of earth and painting with first quality enamel paint on pipe 40 MM Dia (NS)
243Providing & Fixing of M.S. Pipe of medium grade as per IS: 1239, including all accessories like: Tees, Flanges, Bends, Reducer, Nut Bolt, Gas Cut etc. Excavation all types of earth and painting with first quality enamel paint on pipe 32 MM Dia (NS)
244Providing & Fixing of M.S. Pipe of medium grade as per IS: 1239, including all accessories like: Tees, Flanges, Bends, Reducer, Nut Bolt, Gas Cut etc. Excavation all types of earth and painting with first quality enamel paint on pipe 25 mm Dia (NS)
245Providing & Fixing of Bituminized wrapping coating 3mm for anti-rust pipe protection including ruba seal on M.S. pipe complete in all respect.100 MM Dia (NS)
246Providing & Fixing of Single headed S.S. landing valve with 63 MM female coupling on the outlet conforming to IS : 5290 (NS)
247Providing & Fixing of S.S. short branch pipe of 63 MM dia with 16 MM dia outlet Nozzel ISI marked (NS)
248Providing & Fixing of Fire Hose Pipe 63 MM dia (RRL) in 15 Mtr. Length confirming to IS: 636 with S.S male/female coupling confirming to IS : 903 with ISI Marked (NS)
249Providing & Fixing of Hose Box .fabricated from M.S Sheet of heavy guage, having locking arrangement with 4 MM Glass in front to include Hose Pipe and Branch Pipe Nozzel Single Door (NS)
250Providing & Fixing of First – Aid Hose Reel with 30 Mtr. Long rubber tube of 20 MM Dia with Shut off Nozzel of 5 MM Dia confirming to IS : 884 (NS)
251Providing & Fixing of Fire Brigade inlet valve with Non-Return valve and Butterfly. a. Two way F/b inlet. (NS)
252Providing & Fixing of CI Butterfly Valve with nitrite rubber and shell be PN 1.6 rating, confirming to IS: 13095 100 MM Dia (NS)
253Providing & Fixing of CI Butterfly Valve with nitrite rubber and shell be PN 1.6 rating, confirming to IS: 1309580 MM Dia (NS)
254Providing & Fixing of CI Butterfly Valve with nitrite rubber and shell be PN 1.6 rating, confirming to IS: 1309565 MM Dia (NS)
255Providing & Fixing of CI Non-return valve double flanged with disc sealing ring of nitrile rubber and shell be PN 1.6 rating, confirming IS : 13095 / BS- 5155. 100 MM Dia (NS)
256Providing & Fixing of Electric Driven Jockey Pump set consting of the following:• Centrifugal pump of 750 LPM capacity able to building up pressure loss in any leakage in the system against a total head of 40mtrs. With mechanical coupling complete including by pass arrangement for testing the working of the pumps required. • Squirrel cage type A. C induction motor suitable for operation on 415v, 3phase, 50hz, a.c. supply and of 10HP for the above pump flexible coupling with guard as per specification the pump motor should confirm to ISL 325 1978. (NS)
257Providing & Fixing of Cubical type foot mounted control panel complete with suitable relays, contractor, indicating lamps, fuses instruments, isolator automatic star delta type motor starter confirming to IS:1822 and auxiliary switch including connection complete as required for 1 no. Jockey Pump fitted. (NS)
258Providing & Fixing of Pressure switch along with accessories. (NS)
259Providing & Fixing of Pressure gauge 100 mm dial along with stop cock with accessories. (NS)
260Providing & Fixing of Air release valve 25MM (NS)
261Providing & Fixing of Ball Wall Valve 25MM (NS)
262Providing & Fixing of Y-Stainer 100 MM (NS)
263Providing & Fixing of Foot wall valve 100 MM (NS)
264Providing & Fixing of Flexible Pipe long with1000MM/1200MM (NS)
265Providing & Fixing Pendent type sprinkler 680C (NS)
266Conduit pipe 25mm dia heavy gauge complete with all accessories like junction box, bend, saddles, rawl plug, screw etc. 1.5mm copper wire (Armoured cable) (NS)
267Ionization type Smoke detector. Smoke detector (NS)
268Response indicator (NS)
269Hooter/Speaker (NS)
270Manual Call Point (NS)
271Control panel with automatic battery charger of 12 volt. 12 Zone, Panel (NS)
272Electrical Items
273RECESSED PVC CONDUIT PIPE WIRINGSYSTEM WITH MODULAR SWITCHES:Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-Wiring fan point (With fan box) (CSR Item No. - 34.02(i)b)
274RECESSED PVC CONDUIT PIPE WIRINGSYSTEM WITH MODULAR SWITCHES:Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-Wiring light point (CSR Item No. - 34.02(ii))
275RECESSED PVC CONDUIT PIPE WIRINGSYSTEM WITH MODULAR SWITCHES:Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-Wiring 6Amp. wall socket point (CSR Item No. - 34.02(iv))
276RECESSED PVC CONDUIT PIPE WIRINGSYSTEM WITH MODULAR SWITCHES:Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-Wiring 16/20Amp. power plug control point (CSR Item No. - 34.02(vi))
277RECESSED PVC CONDUIT PIPE WIRINGSYSTEM WITH MODULAR SWITCHES:Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-Wiring light point without control switch. (CSR Item No. - 34.02(vii))
278PVC INSULATED FR COPPERCONDUCTOR CABLES: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-Overall size 1.0 sq.mm (Un-sheathed) (CSR Item No. - 34.09 (i))
279PVC INSULATED FR COPPERCONDUCTOR CABLES: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- Overall size 1.5 sq.mm (Un-sheathed) (CSR Item No. - 34.09 (ii))
280PVC INSULATED FR COPPERCONDUCTOR CABLES: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- Overall size 2.5 sq.mm (Un-sheathed) (CSR Item No. - 34.09 (iii))
281XLPE INSULATED ARMOURED CABLES (LOOSE):Supply, laying and erection of aluminum conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-Overall size 240sq.mm (3½ Core) Armoured (Loose) (CSR Item No. - 34.10 B(xxx))
282XLPE INSULATED ARMOURED CABLES (LOOSE):Supply, laying and erection of aluminum conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-Overall size 25sq.mm (3½ Core) Armoured(Loose) (CSR Item No. - 34.10 B(xxii))
283PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD GeneralSpecifications:-Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed) (CSR Item No. - 34.12 (x))
284PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD GeneralSpecifications:-Heavy Gauge PVC Conduit Pipe 50mm dia. (Flushed) (CSR Item No. - 34.12 (xiii))
285Supply and erection of PVC flexible pipe complete without compression glands, locking arrangement, check-nuts as required:-(b) PVC Flexible Pipe 25mm dia. (CSR Item No. - 34.12 (xxv)(b))
286MINIATURE CIRCUIT BREAKERS/ RCBO’s/ RCCB’s: MINIATURE CIRCUIT BREAKERS:Supply and erection of Miniature Circuit Breaker MCB’s for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- GROUP-A: (Siemens (Beta Guard), Legrand (Lexic) & Schneider (Neo Break), L&T (Hager):-MCB Single Pole 6-32amp. (10kA, Curve-C) (CSR Item No. - 34.16 (ii))
287MINIATURE CIRCUIT BREAKERS/ RCBO’s/ RCCB’s: MINIATURE CIRCUIT BREAKERS:Supply and erection of Miniature Circuit Breaker MCB’s for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- GROUP-A: (Siemens (Beta Guard), Legrand (Lexic) & Schneider (Neo Break), L&T (Hager):-MCB Single Pole 50, 63amp. (10kA, Curve-C) (CSR Item No. - 34.16 (iv))
288RCCB:-Supply and erection of RCCB (Residual Current Circuit Breaker) for Earth leakage protection suitable for 240/415 volts 50 cycles AC supply with breaking capacity of 10kA as per IEC 61008-1 in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:RCCB Four Pole 63amp., Sensitivity 30mA (CSR Item No. - 34.16( c) xii)
289SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB"s/RCBO"s/ RCCB"s:Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/RCBO"s/ RCCB"s in the distribution board (For SP&N distribution board with provision DP MCB"s/ RCCB"s/ RCBO"s as incomer and SP MCB"s as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB"s/ RCCB"s/ RCBO"s as incomer and SP MCB"s as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-GROUP-A: (Siemens (Beta Guard/Minigard), Legrand (Ekinoxe) & Schneider (Neo Break), L&T (Hager vision+)TP&N Horizontal Double Door DistributionBoard 8 way each (CSR Item No. - 34.17 (vii))
290SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB"s/RCBO"s/ RCCB"s:Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/RCBO"s/ RCCB"s in the distribution board (For SP&N distribution board with provision DP MCB"s/ RCCB"s/ RCBO"s as incomer and SP MCB"s as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB"s/ RCCB"s/ RCBO"s as incomer and SP MCB"s as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-GROUP-A: (Siemens (Beta Guard/Minigard), Legrand (Ekinoxe) & Schneider (Neo Break), L&T (Hager vision+)TP&N Horizontal Double Door DistributionBoard 4 way each (CSR Item No. - 34.17 (v))
291CABLE TRAY:Supply and erection of MS perforated cable tray (MS Sheet thickness 2mm) with DA gray paint on the existing surface with the help of MS angle iron support (to be painted with approved paint) of size 50mm x 50mm x 6mm thick to be fixed with fastners/ nut & bolts etc., complete in all respect as desired by the Engineer-in-charge and as per PWD General Specifications:- (I) Cable Tray Size 150mm x 50mm x 50mm (2mm thick) (CSR Item No. - 34.25(i))
292Supply and erection of heavy duty aluminum thimbles/lugs for cable end termination duly crimped including making necessary connections completely:-(III) Aluminum thimble cable Core size 25 -35sq.mm (CSR Item No. - 34.38 A(iii))
293Supply and erection of heavy duty brass single compression gland for cable end termination duly complete with check nuts etc. including making necessary connections:-Brass Gland for Aluminum cable 3/3½/4 Core size 240sq.mm (CSR Item No. - 34.38C(xii))
294Supply and erection of heavy duty brass single compression gland for cable end termination duly complete with check nuts etc. including making necessary connections:-Brass Gland for Aluminum cable 3½ Core size 400sq.mm (CSR Item No. - 34.38C (xiv))
295Main LT PanelSupply, assembly, erection, testing and commissioning indoor type floor mounted free standing weather proof panel/DB of guage 14/16 SWG with IP-54 protection fabricated out of suitable sized angle iron and flats and covered with 2mm thick CRCA sheet duly pretreated in seven tank process for de-greasing , de-rusting & phosphate painted with 2 coats of primer paint then the panel/DB surface shall be finished/rubbed and then painted with final coat of epoxy based power coated paint. Panel/DB shall be compartmentrised with rubber gasketed hinged door. Panel/DB shall be having front opening only for installation of separate cable alleys, busbar chamber and switchgear compartments. Provision in cable alleys to be kept for bottom cable entry for incoming & outgoing cables. A clear space of 200mm to be kept from floor level for switchgear compartment. Extended busbar links/ terminals to be provided for connecting cables. Air ventilation breathers to be provided for heat dissipation. Suitable sized knock-out holes for cable glands shall be provided as per respected schematic drg. of the panel with the following equipments / instruments. Paint shall be epoxy based approved make as per shade approved by Engineering Incharge. All MCCB"s shall have rotatory handles and all switchgears shall have LSING protection. Each Compartment shall be numbered / lettered as per the approved drg. Affixing MV Danger plate at suitable intervals/locations controls etc complete in all respects as desired by Engineer Incharge.Incoming630 Amp, ACB, 35kA 2 No.OutgoingsSeparate cubicle chamber with cable alley not less than 300 mm width for installation / connecting the following switchgear with the main bus bar using aluminum bus link or copper conductor flexible wires suitable to the switch rating and connecting outgoing terminals of the switchgear with terminal blocks of appropriate current rating using flexible copper wires duly terminated by cable lugs and thimbles.4 nos. 315A MCCB and 4 nos. 250 A MCCB (NS)
296Providing, laying and fixing 300 mm dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with Cement mortars 1:2 (1 cement : 2 fine sand) including trenching (75cm deep) and refilling etc. as required. (NS)
297Supply and laying of Cat6 cable in existing conduit (NS)
298XLPE INSULATED ARMOURED CABLES (LOOSE):Supply, laying and erection of aluminum conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-Overall size 400sq.mm (3½ Core) Armoured (Loose) (CSR Item No. - 34.10 B(xxxii))
299500 KVA, distribution transformer 11 KV/0.415 KV ((GeM Rate))
300ICTPN Swtich 600/630 Amp. 415volts ((GeM Rate))
301ACSR Conductor Wolf200sq.mm ((GeM Rate))
302OVER HEAD DISTRIBUTION INSULATORS, STAYSETS & CRADLE GUARDS:(i) Supply and erection of insulators confirming to IS-2544 & 5350 (Test Certificates of CPRI) includes supply and erection of nuts bolts and other accessories whatsoever required at site for fixing it to the structure pole. The job is to be completed as approved by Engineer-in-charge:-Shackle Insulator (Medium) (CSR Item No. - 34.35 (i) (d))
303OVER HEAD DISTRIBUTION INSULATORS, STAYSETS & CRADLE GUARDS:(i) Supply and erection of insulators confirming to IS-2544 & 5350 (Test Certificates of CPRI) includes supply and erection of nuts bolts and other accessories whatsoever required at site for fixing it to the structure pole. The job is to be completed as approved by Engineer-in-charge:-11kV Lighting Arrestor with clamps of required size (With seprate earth) (CSR Item No. - 34.35 (i) (e))
304STAY SETS:Supply and erection of Stay Set consisting of 19/20mm dia.of suitable length G.I. stay rod duly threaded upto 300mm at one end and shaped on the other end. MS plate size 30cm x 30cm x 6mm with 20mm dia. hole drilled in the centre of the plate G.I. stay wire size 7/10 SWG, G.I. thimble for stay binding, Egg/Strain insulator, MS elbow made out of 16mm plain sheet and a 20cm long piece of 50mm x 50mm x 6mm angle iron made to the shape asapproved by Engineer-in-charge. Stay set complete shall be fixed to the pole by providing suitable size full clamps made out 50mm x 6mm size MS flat with required number of nut and bolts 16mm dia. on one end and shall be embedded in the on the other end. The stay plate shall be covered with cement concrete having total volume of the concrete not less that 0.042Cum. The job shall include excavation of pit and back filling and after pouring concrete with excavated soil etc. as approved/desired by the the Engineer-in-charge:-Stay Set consisting of 19/20mm dia., 1.8 metre LongG.I. Stay Rod (CSR Item No. - 34.35 (ii) (a))
305HT & LT LINE ITEMS: Supply & erection of 11kV GO switch confirming to ISI specifications. The item includes supply and erection of operating pipe and handle arrangement of MS flat 50mm x 6mm and channels 75mm x 40mm sheet. The GOswitch is to be fitted with locking arrangement so as it locks upward on "ON" position and locks downward in "OFF" position. The entire GO switch assembly/unit should be properly earthed and the job is to be completed as approved by Engineer-in-charge. (CSR Item No. - 34.38 (vii))
306HT & LT LINE ITEMS: Supply & erection of "D" iron clamp 50mm x 6mm flatiron complete with fixing bolts and nuts (16mm x200mm)including making holes in the pole as approved by Engineer-in-charge. (CSR Item No. - 34.38 (viii))
307Platform for Sub-station fencing with gates. (LS) (CSR Item No. - NS)
308Supply and erection of 3-Stepped steel tubular swaged and welded pole (410-SP-Mpa) of suitable length conforming to IS: 2713- (PART-II)-1980 (Steel tubes conforming to IS: 1161-1979, UTS 42 kgf/ Sq.mm) to fix up to a required planting depth below ground level in a hole of excavation about 45 cm dia. and suitable depth to fill up to 15 cm below G/L with 1:2:4 cement concrete mixture including painting of pole with two coats of approved aluminium paint as required:-Overall length 9 metre, with planting depth 1.5 metre, length of sections 5 metre, 2 metre and 2metre (Bottom, Middle and Top respectively), Outer dia and thickness of sections 165.1mm x 4.85mm, 139.7mm x 4.5mm and 114.3mm x 3.65mm (Bottom, Middle and Top respectively) with approximate weight 154 kg. (410 SP-32) base Plate weight 7.5 kg. of size 12mm thick about 30 cm dia. (CSR Item No. - 34.31 (viii))
309MS CHANNELS/ FLATS:Supply and Erection of MS angle iron (Channel)/ MS Flats of suitable size with cutting, bending and necessary holes as desired by Engineer-in-charge at site:-MS angle iron size 75mm x 40mm x 4mm thick (CSR Item No. - 34.38 (xv) (f))
310Providing and laying, jointing, fixing, testing ISI Marked G.I. Pipe (as per IS 1239) BClass, premium make such as (Jindal Hisar) including cost of Specials such as tees, bends, sockets elbow etc., cutting, threading and testing in trenches in the ground complete.80mm i/d (CSR Item No. - 28.36 (h))
311G.I. EARTHING:Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. to make a mesh around the GI Pipe) with G.I. reducing socket including erection of the same, 4.50 metre (14.76 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 8 metre in length (including boring & refilling).Earthing with 7/14 S.W.G. (7/2.18mm dia.) G.I. rope in20mm dia G.I. pipe with G.I. reducing socket 50mm x20mm (upto 8Metre in length) (CSR Item No. - 34.13 (xiii) (b))
312Nut & Bolt of sorts with washer (NS)
313Supply, installation, testing and commissioning of magnetic track with Dali dimming compatible for spot and general light( Make - Flos / Delta / Hibec pro) complete with all accessories (NS)
314Supply, installation, testing and commissioning of spot light with 15watt LED Dali dimmable fitted in existinh magnetic track( Make - Flos / Delta / Hibec pro) complete with all accessories (NS)
315Supply, installation, testing and commissioning of downlight with 10 watt Dali dimmeable LED fitted in existinh magnetic track( Make - Flos / Delta / Hibec pro) complete with all accessories (NS)
316Supply instalation , testing and commissioning of Dali ballast for magnetic track (make - Tridonic/ ATCO all accesspries. (NS)
317Supply, test, install and commissioning 48" (1200mm) ceiling fan with double ball bearing off white complete with petty material for connection as per satisfaction of Engineer-in-charge of make Havells model Velocity or Bajaj or Crompton high speed (Entrust 50) ((GeM Rate))
318Supply and erection of wall fan heavy duty Almornard make sizes 16’’ complete with MS clamp and its fitting with 4 No fasteners and complete the job all respect to the entire satisfaction of engineer in charge. make Almorned, Crompton or GES ((GeM Rate))
319Supply and erection of 15" Exhaust fan 900 rpm turbo force single phase of make Crompton/Havell"s ISI marked heavy duty motor with die cast Aluminum rotor mounted on two ball bearing including erection, connections and testing etc. complete with flexible wire and petty material reqd. for connections complete in all respects as appd. and desired by the Engineer in-charge at site. ((GeM Rate))
320Supply and installation of 15 watt LED down lighter ( Phillips/Osram) complete with all accessories ((GeM Rate))
321Supply and installation of 25 watt LED spot light , Dali dimmable(Make - Delta , Osram, hi bec pro)complete with all accessories (NS)
322Supply, erection, testing and commissioning of wall mounted up lighter with 9 watt LED in 3000 deg. K. col. temp( Make - Uni lamp, Delta ) with All accessories (NS)
323Supply, erection, testing and commissioning of 1000mm long surface mounted liner channel with 12 watt LED in Amber colour( Make - Unilamp , LED liner) (NS)
324Supplying and drawing co-axial TV cable RG- 6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned opper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. (NS)
325Providing and laying G. I. tape 32 mm X 6 mm from earth electrode directly in ground as required. (NS)
326Supply, erection, testing and commissioning of chemical earthing of CU Electrode / pipe-in-pipe technology, using mild steel pipes, outer pipe dia 76 mm (wall thickness: 1.6 mm) inner pipe dia 38 mm (wall thickness 2.6 mm), terminal hole 14 mm dia, terminal size: 65x57x5 mm, length 3000 mm, hot dip galvanized with about 80-100 microns zinc coating and filled with anti corrosive Crystalline Conductive Chemical Mixture; and suitable soil friendly moisture retaining Backfill compound and FRP Pit cover confirming to IS 3043:1987 of make JMV model no. 393GI or equivalent make of Ashlok or JSE complete as per specifications as desired by Engineer Incharge. (NS)
327Supply ,Installation , testing and commissioning of Main Processor unit capable of interfacing to other equipment by means of RS 232, contact closure interface, IR interface or TCP/IP communication over network, also capable of running automatically(time clock function retained) and manually (Via all wall stations), also multiple processor system to operate under single database and processor can communicate to radio frequency lighting control components with low voltage protection and 24V DC Din rail power supply (NS)
328Supply, Installation, testing and commissioning of Switching module to integrate up to 4 individually controlled zone, each with a capacity of up to 10 Amps. Of height in rush lighting load(Magnetic fluorescent ballast, electronic flour cent ballast, incandescent low voltage, magnetic low voltage and neon/cold cathode load , turn all zones to full output during emergency state via direct contact clousue input and disable control operations until emergency signal is cleared and passively cooled via free convection, unaided by fans or other means. (NS)
329Supply, Installation, testing and commissioning of Analogue dimming module to integrate up to 4 individually controlled zone, each with a capacity of up to 10 Amps. Of height in rush lighting load(Magnetic fluorescent ballast, electronic flour cent ballast, HID, magnetic low voltage and neon/cold cathode load , turn all zones to full output during emergency state via direct contact clousue input and disable control operations until emergency signal is cleared and passively cooled via free convection, unaided by fans or other means. (NS)
330Supply ,Installation , testing and commissioning of DALI dimming module to integrate up to 2 individually controlled zone, Of height in rush lighting load(Magnetic fluorescent ballast, electronic flour cent ballast, HID, magnetic low voltage and neon/cold cathode load , turn all zones to full output during emergency state via direct contact clousue input and disable control operations until emergency signal is cleared and passively cooled via free convection, unaided by fans or other means. (NS)
331Supply ,Installation , testing and commissioning of Motor module to integrate up to 4 individually controlled zone (NS)
332Supply installation and testing and commissioning of Wireless module with clear connect RF technology for communication with radio power saver occupancy sensors, radio power saver and Pico wireless controllers (NS)
333Supply installation and testing and commissioning of Wireless controls communicate using Radio Frequency (RF) at 431 - 437 MHz. Thousands of system addresses prevent interference between systems. (NS)