Construction Of Kailashahar Dist Jail At Kailashahar, Unakoti District Tripura/ Sh: Constn Of100 Seated Prisoners Ward(Male), 25 Seated Prisoners Ward (Female), 10 Seated Prisoners Cell, Administrative Block, Office & Visitor Room, Guard Room, Kitchen Roo, kailashahar-Tripura

Public Works Department-PWD has published Construction Of Kailashahar Dist Jail At Kailashahar, Unakoti District Tripura/ Sh: Constn Of100 Seated Prisoners Ward(Male), 25 Seated Prisoners Ward (Female), 10 Seated Prisoners Cell, Administrative Block, Office & Visitor Room, Guard Room, Kitchen Roo. Submission Date for this Tender is 21-09-2023. Building Work Tenders in kailashahar Tripura. Bidders can get complete Tender details and download the document.




Tender Notice

39487660
Construction Of Kailashahar Dist Jail At Kailashahar, Unakoti District Tripura/ Sh: Constn Of100 Seated Prisoners Ward(Male), 25 Seated Prisoners Ward (Female), 10 Seated Prisoners Cell, Administrative Block, Office & Visitor Room, Guard Room, Kitchen Roo
Open Tender
Indian
Tripura
kailashahar
21-09-2023

Tender Details

Construction Of Kailashahar Dist Jail At Kailashahar, Unakoti District Tripura / Sh: Constn Of100 Seated Prisoners Ward ( Male ) , 25 Seated Prisoners Ward ( Female ) , 10 Seated Prisoners Cell, Administrative Block, Office & Visitor Room, Guard Room, Kitchen Room, Dining Hall, Barrack For 15 Persons, Internal Boundary Wall, Internal Bundarywall Surrounding Female Ward, Perimeter Wall, Watch Tower And Staff Quarter ( Type-I 8 Units ( 2 Block Twin Double Storied ) , Type-Ii 8 Units ( 2 Block Twin Double Storied ) & Type-Iii 8 Units ( 2 Block Twin Double Storied ) / Building Portion Including Internal Water Supply And Sanitary Installation / Sh: Providing E.I For 24 ( Twenty Four ) Nos Staff Quarter Thereof I / C Conceal E.I For Jail

Key Value

Document Fees
INR 1000 /-
EMD
INR 44115.0 /-
Tender Value
INR 22.05 Lakhs /-

BOQ Items

Name of Work:- Construction of Kailashahar Dist Jail at Kailashahar, Unakoti District Tripura/ SH: constn of100 seated prisoners ward(male), 25 seated prisoners ward (female), 10 seated prisoners cell, Administrative Block, Office & Visitor room, Guard Room, kitchen Room, Dining Hall, Barrack for 15 persons, Internal boundary wall, internal bundarywall surrounding female ward, perimeter wall, Watch Tower and Staff quarter ( Type-I 8 units( 2 block twin double storied), Type-II 8 units ( 2 Block twin double storied) & Type-III 8 units ( 2 Block twin double storied)/ Building portion including internal water supply and sanitary installation/SH: Providing E.I for 24(twenty four) nos staff quarter thereof i/c conceal E.I for jail.
Sl. No. Item Description
1Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with wooden switch board with bakelite cover and piano type switch including connection etc as required.( As per TSR 2021 Sl. 101)
2Short point:
3Medium point:
4Long point:
5Wiring for light/ fan/ exhaust fan/ call bell point with 2x1.5 sq. mm PVC insulated copper conductor cable (FR) in existing PVC conduit (medium gauge) recessed in slab/ wall complete with 6/10 amps modular type switch, cover plate, GI box including necessary connection etc. as required.( As per TSR 2021 Sl. 501)
6Providing and fixing of 3 pin 5/6 amps plug point withpianotype 5/6ampsswitch andsocketincludingconnectionwith 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) onswitch board, earthing the 3rd pin etc. as required.( As per TSR 2021 Sl. 103)
7Providing and fixing of 3/6 pin15/16 amps plug point withpianotype 15/16ampsswitch andsocketincludingconnectionwith 2x2.5 sq. mm PVC insulated Copper conductor cable (FR) onswitch board, earthing the 3rd pin etc. as required.( As per TSR 2021 Sl. 104)
8Providing and fixing of 3 pin 6/10 amps plug point withmodulartype 6/10ampsswitch andsocketincludingconnectionwith 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) on surface modularswitch board, earthing the 3rd pin etc. as required. ( As per TSR 2021 Sl. 203)
9Wiring for circuit /Sub-main with following sizes PVC insulated copper conductor cable (FR) in PVC casing and capping etc. as required.( As per TSR 2021 Sl. 205)
102x1.5 sq.mm:
112x2.5 sq.mm:
122x4 sq.mm:
132x6 sq.mm:
14Wiring for Circuit/Sub-main with the following sizes of PVC insulated Copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/surface including connection etc. as required. ( As per TSR 2021 Sl. 503)
151x1.5 sq.mm:
162x2.5 sq.mm:
172x4 sq.mm:
18Supplying and fixing of the following PVC conduit (medium gauge) with all accessories on slab/recessed on wall etc as required.( As per TSR 2021 Sl. 603)
1919/20 mm dia
2025 mm dia
21Earthing with 40 mm dia G.I. Earth pipe (medium gauge) 4.5 m. long complete with masonry enclosure on top CI cover plate size 12"x 12" having locking arrangement including CC work, holes on earth pipe etc. as required.( As per TSR 2021 Sl. 701)
22Extra for using salt (5 kg) and charcoal (46kg) for pipe earth electrode as required. ( As per TSR 2021 Sl. 702)
23Proving and fixing / drawing of 4.06 mm dia (8 SWG) G.I. wire on surface or in existing G.I/ PVC/ Polythene pipe for loop earthing as required.( As per TSR 2021 Sl. 706)
24Supplying and fixing of the following sizes PVC conduit (medium gauge) on surface with all accessories etc. as required.( As per TSR 2021 Sl. 602)
2519/20 mm dia
26Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick i/c accessories and providing masonry enclosure withCIcover plate Size 12"x 12" having locking arrangement, alongwith20 mm dia (medium gauge) watering pipe including CC work etc as required. ( As per TSR 2021 Sl. 704)
27Extra for using salt (12 kg) and charcoal (96kg) for plate earth electrode as required. ( As per TSR 2021 Sl. 705)
28Supply and fixing of 25mm x 5mm GI strip on wall/ floor of the building for horizontal/ vertical run including necessary spacers and porcelain insulators at regular intervals. ( As per TSR 2021 Sl. 712)
29Supply and fixing of 32mm x 6 mm GI strip on walls/ floor of the building for horizontal/ vertical run including necessary spacers and porcelain insulators at regular intervals. ( As per TSR 2021 Sl. 713)
30Supply and fixing of the following sizes GIprongwith necessary nuts & bolts etc as required grouted on roof for Lightning protection.( As per TSR 2021 Sl. 713)
31G.I Prong 450 mm long
32Supplying and installation of Switch disconnector fuse unit (main switch) of the following ratings with all accessories including necessary connection etc. as required.( As per TSR 2021 Sl.1202)
3332 amps 240 volts DP main switch (rewireable)
34Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/415 volts MCB/Isolator/RCCB (SP/SPN/DP/TP/TPN/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connectionas required.( As per TSR 2021 Sl.1208)
35(2+4) / 6way SPN MCB DB (double door)
36(2+6) / 8way SPN MCB DB (double door)
37Supplying & installation of 10 KA breaking capacity, B/C curve MCB of following ratings in the existing MCB DB including connectionas required.( As per TSR 2021 Sl.1215)
386 to 32 amps SP MCB
39Supplying, installation, testing & commissioning of powder coated prewired panel board suitable for 415 volts TP MCCB as incomer & outgoing including busbar & connection as required of the following ratings & sizes. ( As per TSR 2021 Sl.1210)
404 way TP MCCB outgoing & TP MCCB incomer upto 400 amps
41Supplying, installation, testing & commissioning of powder coated prewired digital meter module complete with ammeter, voltmeter, phase indicator lamp, control fuses, CTs, in the existing panel board including connection etc. as required.( As per TSR 2021 Sl.1212)
42Supplying, installation, testing & commissioning of powder coated side cable module (1 pair) in the existing panel board including connection etc. as required suitable for the following sizes and ratings.( As per TSR 2021 Sl.1213)
434/6 way outgoing and incomer upto 400 amps
44Supplying & installation of TP/FP MCCB of following ratings in the existing MCCB enclosure/ panel board including connection etc as required (Ics=100% of Icu with adjustable settings)( As per TSR 2021 Sl.1219)
45a.125 amps TP MCCB, Breakingcapacity 25KA (Thermal Magnetic)
46a.125 amps TP MCCB, Breakingcapacity 25KA (Thermal Magnetic)
47Supplying and fixing of following surface/recess mounted LED luminaries in powder coated die cast housing complete with high efficiency polycarbonate diffuser and necessary connection etc.as required (with 50000 burning hours and minimum lumen output of 100 lm/watt)( As per TSR 2021 Sl.1101)
48Box type single FTL fittings of CRCA steel sheet housing complete with 36/40 W FTL,electronic ballast and high quality reflector cover.
49Decorative wall mounting fancy bracket light fixture suitable for GLS or retrofit CFL/LED (without lamp)
50Supplying and fixing of following surface/recess mounted LED luminaries in powder coated die cast housing complete with high efficiency polycarbonate diffuser and necessary connection etc.as required (with 50000 burning hours and minimum lumen output of 100 lm/watt)( As per TSR 2021 Sl.1101)
51b. Surface mounted round/Square shaped 12 watt LED downlight with integral driver and high quality polycarbonate diffuser.
52Supplying & fixing of 1200 mm sweep white color AC ceilingfan capacitor typedouble ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated Copper conductor cable(FR)(ISI marked, BEE 1star/minimum service value 4.0 m3/min/W) ( As per TSR 2021 Sl.802)
53Supplying & installation of 300 mm sweep metalic body exhaust fan including connection etc as required. ( As per TSR 2021 Sl.817)
54Supplying & installation of shutter for 225/230/300 mm sweep metalic body exhaust fan in the existing hole as required. ( As per TSR 2021 Sl.821)
55Making different sizes of hole in the wall for fixing of exhaust fan including finishing the same with cement plastering and painting etc as required. ( As per TSR 2021 Sl.831)
56Supplying and fixing of MS frame made of (25mm x 25mm x 5mm) MS angle with necessary support by (40mm x 6mm) MS flat and 12 mm thick marine plywood on top, grouted on wall with 4 noslegs (25mmx25mmx5mm MS angle20 cm long) finishedwith red oxide and 2 coat synthetic enamel paintincluding necessary cc work, mending the damages & painting etc as required.( As per TSR 2021 Sl. 1502)
57Supplying of 25 cm long ‘L’ hook made with 40mm x 6mm MS flat and fixing with necessary fasten nuts including finishing, painting etc as required.(as per TSR 2021 Sl.1508)
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail