Tender For Modification Works Such As Providing And Fixing Of False Ceiling False Flooring Rearrangement Of Existing Aluminium Partitions Internal Paintings And Other Miscellaneous Works For The Proposed One Building One Ac Equipment Room In The First Flo, Karimnagar-Telangana

Bharat Sanchar Nigam Limited-BSNL has published Tender For Modification Works Such As Providing And Fixing Of False Ceiling False Flooring Rearrangement Of Existing Aluminium Partitions Internal Paintings And Other Miscellaneous Works For The Proposed One Building One Ac Equipment Room In The First Flo. Submission Date for this Tender is 11-09-2023. False Celing Tenders in Karimnagar Telangana. Bidders can get complete Tender details and download the document.




Tender Notice

39478485
Tender For Modification Works Such As Providing And Fixing Of False Ceiling False Flooring Rearrangement Of Existing Aluminium Partitions Internal Paintings And Other Miscellaneous Works For The Proposed One Building One Ac Equipment Room In The First Flo
Open Tender
Indian
Telangana
Karimnagar
11-09-2023

Tender Details

Modification Works Such As Providing And Fixing Of False Ceiling False Flooring Rearrangement Of Existing Aluminium Partitions Internal Paintings And Other Miscellaneous Works For The Proposed One Building One Ac Equipment Room In The First Floor

Key Value

Document Fees
INR 590 /-
EMD
INR 21630.0 /-
Tender Value
INR 10.81 Lakhs /-

BOQ Items

Name of Work :Modification works such as providing and fixing of false ceiling, false flooring, rearrangement of existing aluminium partitions, internal paintings and other miscellaneous works for the proposed One Building One AC Equipment Room in the First Floor of TELEPHONE BHAVAN, KARIMNAGAR.
Sl. No. Item Description
1Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 3.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
2Cement mortar 1:4 (1 cement : 4 coarse sand)
3Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
4Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :
5300x16 mm
6Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete :
7300x10 mm
8Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
9Twin rubber stopper
10Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection > 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity <0.043 w/mK.
1112 mm cement plaster of mix :
121:6 (1 cement: 6 coarse sand)
1315 mm cement plaster on rough side of single or half brick wall of mix :
141:6 (1 cement: 6 coarse sand)
15Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade.
16New work (two or more coats) over and including water thinnable priming coat with cement primer.
17Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :
18Water thinnable cement primer
19Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:
20Two or more coats on new work.
21Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
22Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
23For fixed portion
24Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
25For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately).
26Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
27Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS:12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-in-charge.
28Pre-laminated particle board with decorative lamination on both sides.
29Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
30With float glass panes of 4.0 mm thickness (weight not less than 10 kg/sqm)
31With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
32Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg., for doors, including cost of cutting floors ,embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge.
33With stainless steel cover plate minimum 1.25 mm thickness. ations, footings, bases of columns, etc. for mass concrete
34Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
35Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary screws etc. complete.
36Anodized (AC 15) aluminium
37Providing and fixing aluminium round shape handle of outer dia 100mm with SS screws etc. complete as per direction of Engineer-in-charge
38Anodized (AC 15 ) aluminium
39Providing and fixing removable raised/false access flooring with system and its components of approved make for different plenum height with possible height adjustment upto 50 mm, comprising of modular load bearing floor panels supported on G.I. rectangular stinger frame work and G.I. Pedestal etc. all complete, as per the architectural drawings, as specified and as directed by Engineer-in-charge consisting of:
40(a) Providing at required spacing to form modular framework, pedestals made out of GI tube of thickness minimum 2 mm and 25 mm outer diameter, fully welded on to the G.I. Base plate of size 100mm x 100mm x 3mm at the bottom of the pedestal tube, G.I. pedestal head of size 75mmx75mmx3.5 mm welded with GI fully threaded stud 16mm outer diameter with two GI Check nuts screwed on the stud for level adjustment upto 50mm, locking and stabilizing the pedestal head in position at the required level. The pedestals shall be fixed to the subfloor (base) through base plate using epoxy based adhesive of approved make or the machine screw with rawl plug.
41((b) Stringers system in all steel construction hot dipped galvanized of rectangular size 570x20x30x0.80mm thick having holes at both ends for securing the stringers on to the pedestal head using fully threaded screws ensuring maximum lateral stability in all directions, the grid formed by the pedestal and stringer assembly shall receive the floor panel, this system shall provide adequate solid, rigid support for access floor panel, the system shall provide a minimum clear uninterrupted clearance between the bottom of the floor for electrical conduits and wiring etc. all complete as per the architectural drawings, as specified and as directed by the Engineer-in-charge.
42(c) Providing and fixing Access Floor panel of 600x600x32 mm medium grade Filled Steel anti static high pressure Lamination of 800H grade (FS800H). Access Floor panel shall be steel welded construction with an enclosed bottom pan with uniform pattern of 64 hemispherical cones. The top and bottom plates of Steel Gauges: top 0.6 mm and bottom 0.7 mm fused spot welded together (minimum 64 welds in each dome and 20 welds along each flange).
43The panel should be Corrosion resist epoxy coated for lifetime rust protection and cavity formed by the top and bottom plate is filled with Pyrogrip noncombustible Portland cementitious core mixed with lightweight foaming compound. The access floor shall be factory finished with Anti-static High Pressure laminate with Non Warp technology upto 1mm thickness for superior adhesion and Surface flatness within 0.75mm.The panel is to withstand a Concentrated Load of 363 kgs applied on area 25mm x 25mm without collapse in the centre of the panel which is placed on four steel blocks. The panel will withstand and Uniformly Distributed Load (UDL) minimum 1250 kg/sqm and an impact load of 50kg all complete as per the approved manufacturers specification and as per the direction of Engineer-in-charge. All specification must be printed on the side of the panel to ensure the quality of the product.
44450 mm Finished Floor Height (FFH).
45Dismantling existing aluminium partitions/ wooden wall panelling, doors and other frames including proper numbering, loading and unloading,stacking and placing at the required place in the building as directed by the Engineer-in-charge. (Area of partition/panelling is measured for payment)
46Fixing of aluminum partitions and doors after making required sections as per the drawingwith available material of aluminum sections , particle board, glass panels, neoprene gasket and snap on beading including fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions at top, bottom and sides with required PVC/Neoprene felt etc, aluminum sections shall be smooth, rust free, straight , mitered and jointed mechanically wherever required all complete as per the architectural drawings and the directions of the Engineer-in-charge. (The available material as above on as is where is basis in stacked condition wiil be supplied by the departement at no cost. Finished area of partition is measured for payment)
47Dismantling of false ceiling in true horizontal level, suspended from ceiling usingadjustable rods, resting on periphery walls /partitions on a Perimeter wall. Cost includes all labour fordismantling of false ceiling material including stacking of material etc., all complete as per directions of Engineer-in-charge.
48Removing/dismantling of MS Grill/Window shutters/MS angle frame work for AC"s in windows of size 1.00mx1.20mincluding stacking of material etc., all complete as directed by the Engineer-in-charge.
49Removal of black stains, marks on burnt walls/ceilings by scrapping including cleaning of walls. The cost includes provision of sheets for covering of equipment, scrappers, sand papers, rent for ladders etc., all complete as directed by the Engineer-in-charge.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail