Providing And Fixing Of Lights On Walking And Cycle Track On The Road Starting From Sector 6/7 (Chandigarh-Shimla Highway) And Ending At Sector 4/12 (Upto Shimla - Zirkpur Highway) Panchkula.(Including 3 Years Free Defect Liability Period), panchkula-Haryana

Panchkula Metropolitan Development Authority-agecode007 has published Providing And Fixing Of Lights On Walking And Cycle Track On The Road Starting From Sector 6/7 (Chandigarh-Shimla Highway) And Ending At Sector 4/12 (Upto Shimla - Zirkpur Highway) Panchkula.(Including 3 Years Free Defect Liability Period). Submission Date for this Tender is 19-10-2023. Highway Construction Tenders in panchkula Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

39476778
Corrigendum : Providing And Fixing Of Lights On Walking And Cycle Track On The Road Starting From Sector 6/7 (Chandigarh-Shimla Highway) And Ending At Sector 4/12 (Upto Shimla - Zirkpur Highway) Panchkula.(Including 3 Years Free Defect Liability Period)
Open Tender
Indian
Haryana
panchkula
19-10-2023

Tender Details

Providing And Fixing Of Lights On Walking And Cycle Track On The Road Starting From Sector 6 / 7 ( Chandigarh-Shimla Highway ) And Ending At Sector 4 / 12 ( Upto Shimla - Zirkpur Highway ) Panchkula. ( Including 3 Years Free Defect Liability Period )

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 19-Sep-2023 Corrigendum Date 04-10-2023
2 22-Sep-2023 Corrigendum Other 04-10-2023
3 04-Oct-2023 Corrigendum_2 Date 19-10-2023

Key Value

Document Fees
INR 5000 /-
EMD
INR 192086.0 /-
Tender Value
INR 96.04 Lakhs /-

BOQ Items

Name of Work:Providing and Fixing of Lights on Walking and Cycle Track on the Road Starting from Sector 6/7 (Chandigarh-Shimla Highway) and Ending at Sector 4/12 (upto Shimla - Zirkpur Highway) Panchkula.(Including 3 years free defect liability period)
Sl. No. Item Description
1[23.22.1.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.3. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 16 to 100 Amp, 25 KA
2[23.22.5.4]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.4. Supply and erection of miniature circuit Breaker240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. Double pole
3[23.22.5.8]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.8. Supply and erection of miniature circuit Breaker240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCBs FOUR POLE
4[23.22.6.2]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 6.2. Supply and erection double pole/Four pole Residual (RCCB/ELCB) on 240/415V, 5Hz. AC supply installed in existing sheet steel enclosures including making necessary connections and bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. DP RCCB 30ma sensitivity , 40 A
5[23.27.1]Supply and erection of Godrej Almirah typeM.S. pedestal made of 50 mm x 50 mm x 6 mm angle iron frame with 3.00 mm thick M.S. sheet covering including shutters with suitable hinges and locking arrangement with Godrej type handle including round bars . The top covering should have downward overhang of 75 mm on all sides of pedestal , having two sets of water proof ventilation holes of suitable size on the sides , at top and bottom , each set containing four Nos. holes to discharge the heat produced by the current . The shutters fixed with rubber gasket of superior quality and of suitable size to make it water proof .The pedestal duly painted both inside and outside with two coats of approved paint and primary coat and its legs are embeded upto the entire depth in 1:2:4 cement concrete block , projected 75 mm all around the pedestal and and 200 mm above the ground level including the cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work:- 1. M.S. pedestal of size 600 mm wide , 750 mm high ,300 mm deep and bottom totally open , duly embeded in 1:2:4 cement concrete block of size 750 mm x 450 mm x 200 mm above ground level , having a base of size 900 mm x 600 mm x 250 mm below ground level.
6[23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work.PVC pipe of 25 mm dia.
7[24.1.1]EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required.
8[24.1.2]EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required.
9[24.1.3]EARTHING AND LIGHTENING ARRESTOR 3. Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required.
10[24.1.4]EARTHING AND LIGHTENING ARRESTOR 4. Earthing with tinned copper earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but withoutcharcoal or coke and salt) etc. complete as required.
11[24.1.5]EARTHING AND LIGHTENING ARRESTOR 5. Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode.
12[24.10.6]CIVIL ITEMS (USED COMMONLY IN ELECTRICAL WORKS) 6. Digging of pucca road in required width for laying of cable / pipe complete in all respect up to the entire satisfaction of Engineer-in charge
13[24.5.2.3]MISCELLANEOUS ITEMS 2.3. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 63/50 mm outer dia/inner dia
14Supply Erection of PVC insulated and sheathed underground cable, loose in existing pipe or trenches 1100 volts core having solid aluminium conductor wires confirming to IS: 694 including making necessary connection complete in all respect up to entire satisfaction of the Engineer-in-charge.25 Sqmm 4 Core Armoured Make:-Havell’s/Polycab/Grandlay
15Supply Erection of PVC insulated and sheathed underground cable, loose in existing pipe or trenches 1100 volts core having solid aluminium conductor wires confirming to IS: 694 including making necessary connection complete in all respect up to entire satisfaction of the Engineer-in-charge.16 Sqmm 3 Core Armoured Make:-Havell’s/Polycab/Grandlay
16Erection of 15 W LED BOLLARDS Light having height 1000mm, IP65 or above along with foundation of size 0.3m x 0.3m x 0.75m of RCC 1:1.5:3 ( 1 cement : 1.5 coarse sand (zone III) : 3 graded stone aggregate 20mm nominal size and TMT steel bars Fe 500D @ 110kg/ cum with L-Shaped Anchor bolts 04 No. of 300mm length and nuts including excavation of earth and PVC Junction Box with four way double pole connector recessed in foundation and other allied work complete the job in all respect including of the same up to the entire satisfaction of Engineer-in-charge of the work or make as per satisfaction of Engineer-In-Charge).
17Supply and Erection of Sensor based AMSON’s/ Indo Asian make automatic Electronic timer to Switch ON/OFF the street / Road light automatically. It will change switching ON/OFF timings automatically on daily basis throughout the year as per change in timing of sun rising and sun setting suitable for street/ Road lights. It will have three contractors of 24 Volt of BCH (Bhartiya Cutler Hammer) to control load upto 40 Amp. Per phase with voltage ratio @230/240. It will have light activated automatic Switching system to switch ON/OFF of the Road street lights. It will have Auto/ manual systems for maintenance of street light during day time. It should have Transformers with voltage ratio 230/240 and other allied accessories as required. Bakelite sheet to assemble the components etc. It should have Kit Kat of 20 Amps capacity to save the time switch from power fluctuation. The device will be housed in the existing pedestal/box/pole etc. in such a way so that it operates at correct timings and erection of the same at site complete in all respect upto the entire satisfaction of Engineer-In-Charge.
18Supply of LED BOLLARDS Light 1000mm 15 W, IP65 along with PMDA logo printed and 3 years warranty. (Make: Phillips/Halonix/ Havell`s or as per satisfaction of the Engineer-in-charge).The Energy efficient 15 W LED Bollard should have following technical specifications: Main Housing:- Extruded Aluminum, Base:- Aluminum, Diffuser:- PC/PMMA/PS/Acrylic, LED:- LM 80 Certified, Lumen Maintenance:- L70 @ 50000 Hours, Control Gear:- Isolated, Electronic, CC driver. Internal wiring:- PVC insulated copper wire. Hardwares:- SS and MS Zinc plated and Passivated. Ingress Protection:- IP 65. Operating Voltage:- 140V To 270V. Operating temperature:- (-10 Degree Celsius to 50 Degree Celsius)
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail