Military Engineer Services-MES has published Tender For Repair Maintenance Of Summer Appliances And Connected Works At 7 Afh Kanpur Cantt. Submission Date for this Tender is 25-09-2023. AMC of Air Condition Tenders in kanpur Uttar Pradesh. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 18-Sep-2023 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 25-09-2023 |
Sl. No. | Item Description |
1 | M & L for servicing of window type AC 1.0/1.5 TR /2.0 TR capacity at various locations and at any height, like first floor for maintenance including taking down wherever necessary, opening, cleaning with Magna/Hibird solution, applying water/ air pressure, oiling including taking out old unserviceable parts and fixing new part complete with re-fixing at existing place after repairing, servicing, testing etc complete all as specified and directed. |
2 | All as per item No.1.00 here-in-before but split type AC 1.5 /2.0 TR capacity including suitable T&P for cleaning of indoor assembly and making good the disturbed surface or shifting of tables/beds/lockers etc wherever required complete all as specified and directed. Note for item No. 01 & 02:- New components /parts shall be measured and paid separately as "supply only" under respective items of Sch ‘A’. |
3 | Supply only for replacement following items for window/ split type ACs complete all as specified and directed. Note :- Rate for taking out and fixing of components /parts is included in item No 1.00 & 2.00 above |
4 | Starting capacitor of capacity 120-150 MFD. |
5 | Running capacitor 45 MFD. |
6 | Running capacitor 36 MFD. |
7 | Running capacitor 4/6 MFD. |
8 | Starting relay (as per sample) |
9 | Over load protector (as per sample) |
10 | Starting capacitor 100 – 120 MFD. |
11 | Taking down old unserviceable sealed unit and S&F new hermatically company sealed unit compressor of following capacity single phase 230 volt welding/brazing of gas pipe line, vacuum pressure leakage testing complete including charging refrigerant gas as required complete all as specified and directed. |
12 | Sealed unit compressor of 1.5 TR capacity. |
13 | Sealed unit compressor2.0 TR capacity. |
14 | Ditto all as per item no.4.00 here-in-before but rotary type compressor of capacity 1.5 TR complete all as specified and directed. |
15 | Ditto but 2.0 TR capacity all as specified and directed. |
16 | S & F FHP motor single phase of capacity 1/6 HP, 900 RPM, 220 V for 1.5 to 2 TR Capacity of window type AC/split AC complete all as specified and directed. |
17 | All as per item No.6.00 above but for 1/8 HP. |
18 | S & F in replacement cooling coil of capacity 1.5 TR for window type AC including welding/ brazing of pipe line, charging of refrigerant gas and testing of leakage as required complete all as specified and directed. |
19 | All as per item No.8.00 here-in-before but for split type AC 2.0 TR capacity. |
20 | S & F in repair condenser coil for 1.5 TRwindow type AC including welding/ brazing of pipe line, charging of refrigerant gas and testing of leakage as required complete all as specified and directed. |
21 | All as per item No.10.00 here in before but for split type 2TR capacity. |
22 | Charging only of refrigerant gas (R-22) in window type / Split AC"s after detecting the leakage of refrigerant gas in the system and testing complete all as specified and directed. (Note : Gas will be issued under the relavent item here-in-after as "supply only") |
23 | 1.5 TR cap window type AC |
24 | 2.0 TR cap window type AC |
25 | 2.0 TR cap splittype AC |
26 | 1.5 TR cap Split type AC |
27 | Shifting of existing window type AC of any capacity from one location to another location including closing of openeing with brick work in CM (1:6) and its installation by cutting holes in window/walls making good the disturbed surfaces in CM (1:4) and applying two coats of cement base paint on newly plastered surfaces externally and two coats of OBD internally complete all as specified and directed. |
28 | Shifting of existing split type AC of any capacity from one location to another location by complete pumping down refrigerant gas into compressor including disconnecting electrical / gas connection including cutting chases and making good the disturbed surface inCM (1:4)with existing one and its installation by making necessary electric connection including brazing and refixing complete all as specified and directed. |
29 | M & Lfor providing new insulation on existing copper pipe of split type AC including providing 0.64 mm thick alluminium sheet cover, made to shape as required at site for protection of insulating materials from Monkeys menance and weathercomplete all as specified and directed. |
30 | M&L for split type AC outer unit stand made of iron including grouting for fixing with nut, bolts and washers complete all as specified and directed. |
31 | S&F copper pipe along with PVC cushion of size 5/8" dia complete all as specified and directed. |
32 | All as per item no.17.00 above but for size 1/2" dia. |
33 | REFRIGERATOR Servicing of refrigerator of any make and capacity at various location for maintenance including taking out old unserviceable parts and replacing with new parts and re-installing the same at existing place after repairing, servicing and testing complete all as specified and directed. Note :- Spare parts shall be measured and paid separately as "supply only" under respective items of Sch ‘A’. |
34 | Supply only for replacement of following items of Refriegerator complete all as specified and directed. Note :- Rate for taking out and fixing of components /parts is included in item No 19.00 above |
35 | Thermostate (as per sample). |
36 | Thermostate switch as per sample |
37 | Relay as per existing. |
38 | Bulb 230 V, 12 W (as per sample) |
39 | Ice tray PVC 18 cubed. |
40 | Aluminium Chiller box as per sample suitable for 165 to 200 ltrs capacity |
41 | Aluminium Chiller box as per sample suitable for 285 to 310 capacity |
42 | Defrost Switch as per sample |
43 | PVC Chiller tray suitable for 165 to 200 ltrs capacity |
44 | PVC Chiller tray suitable for 285 to 310 ltrs capacity |
45 | PVC Freezer door for 165 to 200 ltrs capacity as per sample |
46 | PVC Freezer door for 285 to 310ltrs capacit as per sample |
47 | Taking down sealed unit from Refriegerator and S & F new sealed unit compressor for 285/300/310 ltr capacity Refriegerator including welding the same with existing refrigerant pipe, leakage testing/vaccum test and supply & charging of refrigerant gas of adequate quantity testing complete complete all as specified and directed. |
48 | Ditto all as per item No.21.00 here-in-before but for 165/180/195/200 ltrs capacity refrigerator. |
49 | S & F in replacement new Condenser coil suitable for 165 / 180 / 195 / 200 Ltrs capacity refrigerator including Welding/brazing of pipe lines, charging of refrigerant gas and testing complete all as specified and directed. |
50 | All as per item No.23.00 here- in-before but for 285/300/310 ltrs capacity refrigerator. |
51 | M & L for denting, cutting and replacing of rusted/ damaged outer cabinet of 285 / 300 / 310 ltrs capacity refrigerator with existing shape and size PBI sheet complete with and including spray painting with one coat of synthetic enamel paint over a coat of primer after proper scrapping of old painted surfaceof refrigerator of approved shade and getting it up to mark in its original position as per existing including necessary welding work, making holes for fixing of compressor complete all as specified and directed. |
52 | All as per item No.25.00 here-in-before but for 165/180/195/200 ltrs capacity refrigerator. |
53 | WATER COOLER M&L for Servicing of water cooler of any make & type of capacity 40 / 80 / 150 ltr by disconnecting electrically & mechanically from various locations for repair and maintenence including cleaning condenser coil and storage tank with chemical base solution and soda water and repalcement of unserviceable parts and refixing, re-connecting electrical and waterconnections, testing etc. complete all as specified and directed. Note :- New components/parts shall be measured and paid separately as "supply only" under respective items of Sch ‘A’. |
54 | Supply only following items for water cooler complete all as specified and directed :- Note :- Rate for taking down and fixing of components /parts is included in item No 27.00 above |
55 | Starting capacitor of capacity 40-60 MFD. |
56 | Starting relay |
57 | Running capacitor 10 MFD. |
58 | Thermostate as per sample. |
59 | PVC float valve with PVC ball,15mm dia |
60 | Push tap self closing Chromium plated 15mm dia (as per sample) |
61 | Brass nipple with GI socked 15mm dia duly welded with tank. |
62 | S & F in replacement sealed compressor unit single phase, 230 V for water cooler including welding/brazing of gas pipe line, vacuum / pressure leakage testing etc. supply and charging of refrigerant gas of adequate quantity and testing complete all as specified and & directed for the following capacity :- |
63 | 40 ltr capacity. |
64 | 80/40 ltr capacity. |
65 | 150 ltr capacity. |
66 | S & F in repair condensor coil complete with copper tube and aluminium fins for water cooler of capacity upto 80 Ltrs including necessary refrigerant gas charging andtesting complete all as specified and directed. |
67 | S & F in repair sheet metal enclosures with 2 pins and earth plug single pole neutral link and one No MCB SP 32 amp complete all as specified and directed. |
68 | S & F in repair sheet metal enclosures with 2 pins and earth plug single pole neutral link and one No MCB SP 40 amp complete all as specified and directed. |
69 | S & F in replacement FHP motor single phase suitable for 40 ltrs/hr capacity water cooler of approved make complete all as specified and directed. |
70 | All as per item No.33.00 here-in-before but for 80 ltrs/Hr water cooler. |
71 | Shifting only water cooler of any capacity, at any height at various locations like Ist floor etc with fitting/grouting nut, bolts and making connection of electrical & water supply including testing complete all as specified & directed. |
72 | S&F in replacement 15 mm dia GI tubing medium grade with all necessary fittings such as bend, elbow, socket tee, union etc complete all as specified and directed. |
73 | S & F in repair gun metal gate valve with iron wheel head screwed both ends suitable for GI pipe of size 15mm dia bore complete all as specified and directed. |
74 | S & F in repair stop valve with crutch or butterfly handle screwed down screwed both ends suitable for GI pipe of size 15 mm dia bore complete all as specified and directed. |
75 | S & F in repair PVC connection pipe 15 mm dia x 45 cm long. |
76 | S & F in repair PVC connection pipe 15 mm dia x 60cm long. |
77 | S & F in repair PVC flexible waste water pipe 40 mm dia. |
78 | M & L for denting, cutting and replacing of rusted/ damaged outer cabinet of 40 ltrs capacity water cooler with existing shape and size PBI sheet including spray painting with one coat of synthetic enamel paint over a coat of primer after proper scrapping of old painted surface of water cooler of approved shade and getting it up to mark in its original position as per existing including necessary welding work, making holes for fixing of compressor complete all as specified and directed. |
79 | All as per item No.42.00 here-in-before but for 80 ltrs capacity water coolers. |
80 | DESERT COOLER M & L for servicing of desert coolers of any size/any height by taking down from the existing position, cleaning of bottom tank, side panel etc including repair/replacing unserviceable parts including painting with one coat synthetic enamel paint after preparation of surface of approved quality and colour on internal & external surface complete all as specified and directed. Note:-Spare parts required shall be measured and paid separatley as "supply only" under respective items. |
81 | Supply only in replacement following items for desert cooler complete all as specified and directed :- Note :- Rate for taking down and fixing of components /parts is included in item No 44.00 above |
82 | Capacitor 4 MFD. |
83 | Indicator lamp rounded /rectangular shape |
84 | PVC Pipe transparent heavy duty ½ inch dia. |
85 | Piano type switch one way 5 Amp 240 V. |
86 | PVC distributor 3 ways. |
87 | Wood wool pad 15mm thick made out of chicken wire mesh fitted with fine quality wood wool, bind with GI wire for desert cooler of any make and size complete all as specified and directed. |
88 | Submersible water liftingpump for desert cooler220/230 V single phase Model SX-6, Make- Bansal/summer cool |
89 | Submersible water lifting pump for desert cooler220/230 V single phase Model SX-8, Make- Bansal/summer cool |
90 | Blade assembly any design / shape for 18"" sweep air intake fan of desert cooler complete all as specified and directed. |
91 | Selector switch (rotory type) 3 speed, 230 V, 50 C/S suitable for desert cooler |
92 | PVC insulated andPVC sheathed cable withstranded copper conductor of size 2.5 sq mm (19/0.0076) 3 core. |
93 | S&F Plug top 5 Amps, 230 Volts. |
94 | M & L for fabrication of pedestal stand of size 65 cm x65cm X 75 cm suitable for desert cooler made out of angle iron 35mm x 35mm x 6mm painted with one coat of black paint over a coat of red oxide primer complete all as specified and directed. |
95 | M&L forrepairs to exhaust fan motor 18" sweep, 900 RPM of any make and size by rewinding of stator with super quality enamelled copper wire of existing size, varnishing, heating, replacement of kit consist of ball bearings, motor shaft, shaft seal, bushes including painting with one coat of synthetic enamel black paint and re-install in the desert cooler at site and testing complet all as specified and directed. |
96 | M & L for replacement of desert cooler cabinet locally fabricated (size not less than 65 cm x 65cm x 135cm (Water tank height not less than 35 cm) ) 3 side pockets, top cover and bottom tank including removable vertical members with fins/grills made out of 22 SWG MS Sheet with adjustable front grills version and base suitable for 18” sweep exhaust fan and making holes, PVC distributor 3 way, PVC pipe 3 to 4Mtr, wood wool pad 3 Nos, internal wiring with 5A switch Piano type, light indicator complete all as specified and directed. |
97 | DEEP FREEZER Taking out deep freezer of capacity 262 ltrto 320 ltr from various locations for repair including refixing at site after repair, cleaning the complete condenser coil & storage tank with chemical base solution and soda water including complete restoring electrical connections and testing complete all as specified and directed. Note :- Parts to be replaced shall be measured and paid separately under respective items of Sch ‘A’ as "supply only". |
98 | Supply only following items for deep freezer complete all as specified and directed :- Note :- Rate for taking down and fixing of components /parts is included in item No 49.00 above |
99 | Starting capacitor 80/100 MFD. |
100 | Running capacitor30 MFD. |
101 | Starting relay |
102 | Filter two ways. |
103 | S & F in replacement sealed unit compressor hermatically company sealed for deep freezer of capacity 262 ltr to 320 Ltr, single phase, 230 V and welding/ brazing of gas pipe line, vacuum pressure leakage testing etc including supply and chargingof adequate quantity refrigerant gas, welding/brazing of copper pipe & testing completet compressor complete all as specified and directed. |
104 | S & F in repair FHP motor suitable for262 ltr to 320 ltrs capacity deep freezer including all necessary works complete all as specified and directed. |
105 | VOLTAGE STABILIZER Dismantling of voltage stabilizer upto 5 KVA capacity complete for maintenance, repair and replacement of wornout /unserviceable spares, overhauling & re-assembling including testing and commissioning complete all as specified and directed. Note :- Spares parts shall be measured and paid separately as "supply only" under respective items. |
106 | Supply only following items for stabilizer complete all as specified and directed :- Note :- Rate for taking down and fixing of components /parts is included in item No 53.00 above |
107 | Voltmeter range 0 to 300 Volts for 0.5, 2, 4 & 5 KVA voltage stabilizer. |
108 | Terminal socket3 Pin 15 Amp |
109 | Terminal Connection 4 ways. |
110 | Indicator lamp for 0.5, 2, 4 & 5 KVA stabilizer. |
111 | Main relay for stabilizer upto 5 KVA |
112 | PCB switch transistor, diodes, resistance for 5 KVAvoltage stabiliser as per sample |
113 | Plug top 3 pin 15 Amp, 240 Volt. |
114 | M & L for providing high and low voltage cut out device, high low voltage cut off with time delay relay 2 to 3 minutes, 2-3 minute over low voltage 180 volts AC and high voltage 260 Volt AC at every cut off for 4KVA & 5 KVA capacity voltage stablizer complete all as specified and directed. |
115 | M & L for re-winding of main transformer of 5 KVA voltage stabilizers of any make and size with super quality enamelled copper winding wire of existing size/guage, insulation materials,varnishing, heating, re-assembling including testing off and on load complete all as specified and directed. |
116 | All as per item No.56.00 here-in-before but for 4 KVA voltage stabilizers. |
117 | M & L for spray painting of voltage stabilizer of any make and capacity at diffierent location of 7 AFH with one coat ofenameled synthetic paint of approved colour including scraping cleaning of old painted surfaces including re-writing MES Nos painting by white paint all as specified and directed. |
118 | WALK IN COOLER M & L for repair/overhauling and servicing of walk in cooler of any make and capacity/type by opening the fan cover, blade, bushes internally & externally and providing fresh lubricant , replacement of unserviceable parts and re-assembling the same after repair/overhauling complete all as specified and directed. Note:- Old unserviceable/ spare parts shall be measured and paid separately as "supply only") |
119 | Supply only following items for walk in cooler complete all as specified and directed :- Note :- Rate for taking down and fixing of components /parts is included in item No 59.00 above |
120 | ‘V’ Belt Make : Dunlop/Fenner |
121 | Thermostatic expansion valve. Make as per sample. |
122 | Gas filter assembly. Make as per sample |
123 | Solenoid valve Make : Danfas/Renutral |
124 | High and low cut off switch |
125 | DOL starter type MK-I relay range 6-10 Amp |
126 | Contactor as per existing make |
127 | Door gasket complete as per sample |
128 | Single phase preventor. |
129 | S & F in replacement sealed unit compressor 1.5 TR capacity single phase, 230 V and for Walk-in-cooler, welding/brazing of gas pipe line, vacuum / pressure leakage testing etc. supply and charging of refrigerant gas of adequate quantity and testing complete all as specified and directed. |
130 | M & L for re-winding of motor upto 5 HP capacity 3 phase for walk-in-Cooler with super quality enameled copper winding wire of existing guage including insulation materials, varnishing, heating, re-assembling including taking down the old U/S motor from existing location & re-installing in the original position after re-winding & testing complete all as specified and directed. |
131 | M & L for Charging only of refrigerant gas (R-22)in walk-in-cooler after detecting the leakage of refrigerant gas in the system including welding, brazing and testing complete all as specified and directed. Note : Gas will be issued under the relavent item as "supply only" |
132 | FOUR/TWO BODY STRUCTURE Taking down carefully unserviceable parts of four body/two body structure such as door inter looking system, temperature guage, starting capacitor, running capacitor, door gasket, sealed unit compressor etc including replacing unservicable parts and cleaning, servicing and overhauling of both structure and testing complete all as specified and directed. Note:- Spare parts shall be measured and paid separately under respective items of Sch ‘A’ as "supply only". |
133 | Supply only the following parts of four body/ two body structure complete all as specified and directed:- Note :- Rate for taking down and fixing of components /parts is included in item No 64.00 above |
134 | Door locks system as per sample. |
135 | Temperature Gauge as per sample. |
136 | Starting capacitor 80-100 MFD capacity. |
137 | Running capacitor 36 MFD capacity |
138 | Magnet door gasket as per sample. |
139 | Capillary of existing size. |
140 | Temperature gauge + 4oC to + 2oC |
141 | Dryer as per sample |
142 | Taking out unserviceable cut open sealed unit compressor of two body structure and S & F new hermatically company sealed unit compressor, single phase, 230 V and welding/ brazing of gas pipe line, vacuum pressure leakage testing etc including supply and charging of regrigerant gas, welding of copper pipe & testing complete all as specified and directed. |
143 | M & L for Pumping down/de-caning the complete existing gas from the system of four/two body structure into to empty cylinder with and including cleaning it with nitrogen complete all as specified and directed. |
144 | M & L for Charging only refrigerant gas in four/two body strucuture and testing in all respect complete all as specified and directed. (Note:- Refrigerent Gas will be issued by the deptt free for filling only) |
145 | Supply only refrigerant gas Mafron (R-22) conforming to IS-5160 duly filled in sealed cylinder complete all as specified and directed. Note:- Empty gas cylinder will be issued to the contractor by the department. |
146 | Supply only refrigerant gas R-134 confirming to IS – 5160 duly filled in factory sealed cylinder complete all as specified and directed. |
147 | Supply only refrigerant gas R-410 confirming to IS – 5160 duly filled in factory sealed cylinder complete all as specified and directed. |
148 | Supply only refrigerant gas Mafron (R-32) conforming to IS-5160 duly filled in sealed cylinder complete all as specified and directed. |
149 | M & L for sub main wiring with three runs of single core 6 Sqmm (nominal area) PVC insulated and unsheathed multi stranded copper conductor cable LT 1100 grade FRLS cable drawn in and including PVC Casing and Capping with all necessary fittings and accessories and two run of PVC insulated and unsheathed single core cable multi stranded with copper conductor of size 6 Sqmm as continuous nuetral and earth wire (green in colour ) respectively, run through PVC casing & capping and connected to the terminal and common earth dollycomplete all as specified and directed. Note. Four run of cable and one run of PVC casing and capping and one run of earth continuity wire shall be measured as one run unit. |
150 | S & F in replacement of MCCB, 4 pole adjustable type 36 KA, 400 Amps complete all as specified and directed. |
151 | S & Finreplacement of MCCB, 4 pole adjustable type 36 KA, 350 Amps complete all as specified and directed. |