| 1 | Excavation in trenches not exc 1.5 m wide and not exc 1.5m deep for foundation etc or for laying of cable etcand getting out in soft/loose soil, completeall as specified and directed by Engineer-in-charge. |
| 2 | Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25cm in soft/loose soil, completeall as specified and directed by Engineer-in-charge. |
| 3 | Removing excavated soil to a distance exc 50m and not exc 250 m and depositing where directed at a level not exceeding 1.5 m above the starting point , completeall as specified and directed by Engineer-in-charge. |
| 4 | Dismantling of ACSR or AAC conductors completeall as specified and directed by Engineer-in-charge. |
| 5 | Dismantling insulators any type, any size completeall as specified and directed by Engineer-in-charge. |
| 6 | Dismantling cross-arms of M.S. channel or angle sections etc. complete and setting aside for re-use with in 50m completeall as specified and directed by Engineer-in-charge. |
| 7 | Dismantling concrete poles/ struts, any size completeall as specified and directed by Engineer-in-charge. |
| 8 | Dismantling steel poles/ struts, any size completeall as specified and directed by Engineer-in-charge. |
| 9 | Sand cushioningto the under groundelectric cablecomplete all asspecifiedconsidering19.75 of SSR part -I completeall as specified and directed by Engineer-in-charge. |
| 10 | Supply and fixing of GI tubing, medium grade with and including all fitting and fixtures laid in trenches complete all as specified and directed for the following bore of pipes:- (a)50mm bore |
| 11 | Supply and fixing of GI tubing, medium grade with and including all fitting and fixtures laid in trenches complete all as specified and directed for the following bore of pipes:- (b) 80 mm bore |
| 12 | Material and labour forSub Class\"B\"brickcovering protectionto the eletric cablelaiddry flat transversallyalongthe lengthof cableon sandcushioningwith widthequal to lengthof brickcompleteall as specified and directed by Engineer-in-charge. |
| 13 | Material and labour for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 150 sq. Mm ,3.5 core all as directed and specified by engr in charge. |
| 14 | Material and labour for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 120 sq. Mm ,3.5 core all as directed and specified by engr in charge. |
| 15 | Material and labour for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 95 sq. Mm ,3.5 core all as directed and specified by engr in charge. |
| 16 | Material and labour for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sq. Mm ,3.5 core all as directed and specified by engr in charge. |
| 17 | Material and labour for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sq. Mm ,3.5 core all as directed and specified by engr in charge. |
| 18 | Material and labour for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sq. Mm ,2 core all as directed and specified by engr in charge. |
| 19 | Supply and fixing installation testing and commisining of LT electric panel board totally enclosed (Factory, Fabricated), Outdoor type including stands doubledoor type powder coated inside & outside made out of CRCA sheet not less than 3.15 mm thick with front opening having locking arrangement spray painting internally/externally, including internal wiring with suitable size of copper strip bus bar chamber 3 phase andfour wire type system 415 volts 50 Hz consisting of aluminium bus bar of capacity 400 Ampsand consisting of the following:-(a) MCCB 200 Amps, 4 Pole -1 No(b) MCCB 63 Amps, 4 Pole - 03 Nos(c) MCCB 100 Amps, 4 Pole - 02 Nos(d) MCCB 160 Amps, 4 Pole - 01 Nos(e) Multifunction meter for VAF,KW,KWH etc-1 No (f) Indicator lamp with Holder 3 No-One set |
| 20 | Material and labour for Cable jointing kit for 1.1 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm completeall as specified and directed by Engineer-in-charge. |
| 21 | Material and labour for Cable jointing kit for 1.1 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm completeall as specified and directed by Engineer-in-charge. |
| 22 | Material and labour for Cable jointing kit for 1.1 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 16 sqmm to 35 sqmm completeall as specified and directed by Engineer-in-charge. |
| 23 | Earthing complete with galvanised steel earth plate electrode60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level,onnected to galvanised earth lead wire 32X6mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completeall as specified and directed by Engineer-in-charge. |
| 24 | Earthing complete with galvanised steel earth plate electrode60×60cm.× 3.15mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level,onnected to copper earth lead wire 20X3mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing oncompleteall as specified and directed by Engineer-in-charge. |
| 25 | Material and labour for earthing complete with galvanised steel plate electrode 600mmx600mmx6mm thick buried directly in ground (earth pit not less than 2.25 Mtr deep below ground level) with top edge of the plate not less than 1.50 Mtrs below ground level connected to glavanised earth lead wire 4.0 mm dia by means of bolts, nuts check nuts and washers of galvanised iron or steelearth wire protected by provision of GI medium grade pipe 15mm bore including provision of concrete pit made with 40mm thick cover of RCC 1:2:4 reinforced with6mm dia M.S. round bar placed 75mm c/c and handle of 10mm dia, MS bar made to shape, GI medium grade 20 mm bore pipe for watering perforated at bottom, 1.75 meter long placed on top edge of earth plate, common salt & charcoal filling, funnel, wire mesh and earth work not exceeding 50 meters all as per electrical plate No 5 of SSR Part I (2009) and connected toearth test points all as specified and directed including testing on completeall as specified and directed by Engineer-in-charge. |
| 26 | Supply and fixing of bus bar chambers with MCCB factory febricated suitable for 3 Phase & neutraliron clad with 4 Nos 200 amp rated copper stripswith two Nos Earthing connection bolt and one MCCB 125 Amps, 4 pole, 16KA with locking arrangement front door and back operated complete duly mounted on ground on suitable size of angle iron completeall as specified and directed by Engineer-in-charge. |
| 27 | Supply and fixing of bus bar chambers with factory febricated suitable for 3 Phase & neutraliron clad with 4 Nos 200 amp rated aluminium stripswith two Nos Earthing connection bolt with locking arrangement front door operated complete fixed flush in wall(indoor) and making good the disturbed wall surfaces completeall as specified and directed by Engineer-in-charge. |