Tender For Additional /Alternator And Special Repairs To Otm Accommodation Of Corps Troops Bldg No T-36A & Op / T-381, Provision Of Floor Tile And Mosquito Proofing At Washerman Shop In Bldg No P-482 In 3 Czw & Provision Of Shed For Parking Near Bldg No , Shillong-Meghalaya

Military Engineer Services-MES has published Tender For Additional /Alternator And Special Repairs To Otm Accommodation Of Corps Troops Bldg No T-36A & Op / T-381, Provision Of Floor Tile And Mosquito Proofing At Washerman Shop In Bldg No P-482 In 3 Czw & Provision Of Shed For Parking Near Bldg No . Submission Date for this Tender is 30-09-2023. Building Work Tenders in Shillong Meghalaya. Bidders can get complete Tender details and download the document.




Tender Notice

39368537
Corrigendum : Tender For Additional /Alternator And Special Repairs To Otm Accommodation Of Corps Troops Bldg No T-36A & Op / T-381, Provision Of Floor Tile And Mosquito Proofing At Washerman Shop In Bldg No P-482 In 3 Czw & Provision Of Shed For Parking Near Bldg No
Open Tender
Indian
Meghalaya
Shillong
30-09-2023

Tender Details

Additional / Alternator And Special Repairs To Otm Accommodation Of Corps Troops Bldg No T-36A & Op / T-381, Provision Of Floor Tile And Mosquito Proofing At Washerman Shop In Bldg No P-482 In 3 Czw & Provision Of Shed For Parking Near Bldg No P-484 In Czw At ‘O’ Zone Under Age Br-I At Rms.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 08-Sep-2023 AMENDMENT IN DATES FOR ADDN ALT AND SPECIAL REPAIRS TO OTM ACCN OF CORPS TROOPS BLDG NO T 36A OP T 381 PROVN OF FLOOR TILE AND MOSQUITO PROOFING AT WASHERMAN SHOP IN BLDG NO P 482 IN 3 CZW PROVN OF SHED FOR PARKING NEAR BLDG NO P 484 IN CZW AT O Z Date 23-09-2023
2 23-Sep-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 30-09-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 91180.0 /-
Tender Value
INR 45.59 Lakhs /-

BOQ Items

Name of Work: ADDN/ALT AND SPECIAL REPAIRS TO OTM ACCN OF CORPS TROOPS BLDG NO T-36A & OP/T-381, PROVN OF FLOOR TILE AND MOSQUITO PROOFING AT WASHERMAN SHOP IN BLDG NO P-482 IN 3 CZW & PROVN OF SHED FOR PARKING NEAR BLDG NO P-484 IN CZW AT ‘O’ ZONE UNDER AGE BR-I AT RMS.
Sl. No. Item Description
1Dismantling asbestos cement (Corrugated or semi corrugated) sheets in roof covering etc complete all as specified and directed.
2Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coveringsetc complete all as specified and directed.
3Demolition of plain cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) including removing demolished material off the premises etc complete all as specified and directed.
4Dismantling, floor, hearth or wall tiling including cement mortar bedding etc complete all as specified and directed.
5Dismantling wall and ceiling board fibre, pulp insulation etc or insulation boards any thickness including cover fillets etc complete all as specified and directed.
6Dismantling timber scantlings 40 sqcm and over in section, in unframed work any position etc complete all as specified and directed.
7M&L for granite of 20 mm thick table rubbed and polished on platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite etc complete all as specified and directed.
8Demolition of brick work built in cement mortar or cement lime mortar including all quoins, arches etc complete all as specified and directed.
9Taking down Chowkhat or frames not exceeding 1.5 Sqm each with shutters(Without taking off shutters from the frames etc complete all as specified and directed.
10Taking down shutter exceeding 2 Sqm each from the frames etc complete all as specified and directed.
11All as per item 10.00 (here-in-above) but exceeding 1.5 Sqm but not exceeding 4 Sqm each etc complete all as specified and directed.
12Demolition of reed lathing single or double including battens and plaster or chicken wire lathing etc complete all as specified and directed.
13S & F 0.71 mm dia wire netting of galvanised steel wire of size 12 mm mesh fixed with tinned tack of wire staple etc complete all as specified and directed.
14M&L for rendering 15 mm thick in CM (1:4) on one side of lathing finished even and smooth without using extra cement etc complete all as specified and directed.
15M&L for rendering 12 mm thick in CM (1:6) on other side of lathing finished even and smooth without using extra cement etc complete all as specified and directed.
16M&L for PCC (1:3:6) type C-2 (using 40 mm graded stone aggregate) ,75mm thick as in base/sub base of floor etc complete all as specified and directed.
17M&L for brick work with sub class "B" bricks(using old size burnt bricks) straight or curved on plan exc. 6.00m meanradius built in cement mortor 1:6 etc complete all as specified and directed.
18S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roofcovering /cladding to wall, fixed with self tapping screws etc complete all as specified and directed.
19S&F for pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws etc complete all as specified and directed.
20S & F for4 mm thick of size 600x600mmHSPC (high pressure Steam Cured) pre-primetered self embossed, textured designer boardE-Board Classic to be fixed GI grid/section size 600mmx600mm with main runner 38x24x0.9mm thick ,cross tee 28.6x24x0.9 mm and wall angle 19x19x0.9 mmduly suspended with 2mm dia GI bar hangers 1200mm centre to centre both ways fixed with steel dash fasteners or from purlin from the roof with alignment clip including providing provisions for light fixtures of any size and finallyetc complete all as specified and directed.
21S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification etc complete all as specified and directed.
22M&L for Solid PVC Wall Lining consisting of 5mm thick Plain or coloured with wood grains printed PVC sheet inclusive of solvent cement and fixing at site on PVC frame etc complete all as specified and directed.
23S&F light shade vitrified ceramic tiles 10mm thick of area exc 0.18 sqm but not exc 0.36 Sqm each floors laid over and including 15mm thick screed bed or bedding layer of mortar for laying floor finishes in CM (1:4) set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles etc complete all as specified and directed.
24All as per item 23.00 (here-in-before) but on vertical surfaces such as skirting , dado risers to stepsover and including 10 mm thick bedding layer in CM 1:4,set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles etc complete all as specified and directed.
25S&F Non skid ceramiccolour tiles of 7 to 8mm thick light colour (Square / rectangular) area of each tileexceeding 0.11 sqm but not exceeding 0.18 sqm as in floors laid over and including 15mm thick screed bed or bedding layer of mortar for laying floor finishes in CM (1:6), set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles etc complete all as specified and directed.
26All as per item 25.00 (here-in-before) but on vertical surfaces such as skirting , dado risers to stepsover and including 10 mm thick bedding layer in CM 1:4 , set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles etc complete all as specified and directed.
27M & L for coloured non skid ceramic tiles 7 to 8 mm thick (square/rectangular) in section , area exceeding 0.06 sqm but not exceeding 0.11 sqm as in floorslaid over and including 15mm thick screed bed or bedding layer of mortar for laying floor finishes in CM (1:6) set and jointed in neat cement slurry and pointed in white or coloured cemet to match the shade of tilesetc complete all as specified and directed.
28M&L for Glazed ceramic colour tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tiles laid over and including 10mm thick CM (1:4) backing coat etc complete all as specified and directed.
29M&L forproviding Kota stone slab 20 to 25mm thick machine cut and mirror polished to size and fixed in floor and set and jointed in neat cement slurry and pointed with grey cement to match the shade of stone floor/steps treads over 20mm thick screed bed in CM (1:4) complete all as specified and directed.
30M&L for providing Kota stone slab 20 to 25mm thick machine cut and mirror polished to size and fixed in wall and set and jointed in neat cement slurry and pointed with grey cement to match the stone over and including 10 mm thick rendering in CM (1:4) for laying in vertical surfacescomplete all as specified and directed.
31S&F anodised aluminium powder coated any colour frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. etc complete all as specified and directed.
32S&F for anodised aluminium powder coated any colour door shutter, aluminium section weighting 0.55 kg/m including necessary joining, cleats,glazing clips,rubbber neoprene, packing headls 2 nos in each door hinges anodised aluminium snap beading screw etc complete all as specified and directed.
33S&F for anodised aluminium powder coated any colour window and vantilator shutters, aluminium section weighting 0.55 kg/m including necessary joining, cleats,glazing clips,rubbber neoprene, packing, hinges anodised aluminium snap beading screw etc complete all as specified and directed.
34S&F Sheet glass 4.8mm thick clear/sun shade colour glass, ordinary quality and glazing with oil putty in squares exceeding 0.5sqm in each pane etc complete all as specified and directed.
35Hacking out old broken glass of any thickness size or description from wooden frames or metal frames fixed with wooden beads/ putty etc complete all as specified and directed.
36S&F Sheet glass 3mm thick, ordinary quality and glazing with oil putty in squares not exceeding 0.5sqm in each pane etc complete all as specified and directed.
37All as per item 36.00 (here-in-above) but figured glass,pin head type etc complete all as specified and directed.
38S&Ffor aluminium (extruded section) bodydoor closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed.
39S&F Mortice lock,vertical type Brass 2 levers, size 100 mm etc complete all as specified and directed.
40S & F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing etc complete all as specified and directed.
41S&F Factory made solid panel PVC doorshutter 30 mm thick (style) con-sisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be cov-ered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement suppling & fixing at site as per specification and drawing etc complete all as specified and directed.
42S&FFactory made30 mm thick 2nd class hard wood glazed and skeleton shutters, for door, window and vantilator open rebated and prepared to received glass gauze etc but divided into squares, with plain chamfered or rounded mitred and rebated sash brs any numbers and mitred beds for securing glass, but divided into squared any number etc sizes of members of shutters as specified in SSR Part I, section 8 clause 8.24(a) supplied and fitted to chowkats etc complete all as specified and directed.
43S&FFactory made35 mm thick 2nd class plain framed panelled shutters (any number of panels) with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commericial face veneers: supplied and fitted to chowkats, etc complete all as specified and directed.
44S&F in repair 300 mm MS ordinary rat tail spring including roller and roller plate complete all as specified and directed.
45S&F Alumimiumsliding door bolt 300 mm long stove enamealled black with bright bolt not less than 16 mm dia with and including and minimum of 6 boalts and nuts four on bolt plat and two on staple plate and fixed etc complete all as specified and directed.
46S&F galvanized mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm fixed with tinned tacks or galvanized wire staples complete all as specified and directed
47S&F 100 size stainless steel butt hinges complete all as specified and directed
48S&F Aluminium anodised barrel tower bolt of extruded section and fixed 100 mm long etc complete all as specified and directed.
49S&F Aluminium handle cast type anodised 150 mm long etc complete all as specified and directed.
50M&L for second class hardwood as in scantlings clean sawn timberfixed etc complete all as specified and directed.
51M&L for rolled mild steel in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming to Fe 410-W (Gde-E 250) quality-A etc complete all as specified and directed.
52S&F Post, joist, channel, angle or tee section fixed independently without connection plates etc conforming to Fe-410- W (Gde-E-250) quality A etc complete all as specified and directed.
53S&F for Plate (plane or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment etc conforming to Fe- 410-w etc complete all as specified and directed.
54S&F for Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut,exc 22.5 cm but n exc 30cm long and 16 to 20mm dia of necketc complete all as specified and directed.
55M & L for plain fillets, square, rectangular or triangular in section clean sawn, secured with nails 2nd class hard wood exc 13and n.exc 25 sqcm etc complete all as specified and directed.
56Taking upor down 15 mm GI steel tubing and connections includingwith all fittings for removal to store etc complete all as specified and directed.
57Taking upor down 20 mm steel tubing and connections includingwith all fittings for removal to store etc complete all as specified and directed.
58S&F 15mm bore GI water tubing medium grade laid in floors or fixed in wall including GIfittings etc complete all as specified and directed.
59S&F 20 mm bore GI water tubing medium grade laid in floors or fixed in wall including GIfittings etc complete all as specified and directed.
60S&F in repairs10 ltrs capacity PVC valveless syphonic action type flushing cistern low level with inlet ball valve float and handle etc complete all as specified and directed.
61S&F in repairs vitreous china water closet Padestal pattern (white) excluding fixing bolts, flushing cistern and flush pipe and including EWC Seat cover etc complete all as specified and directed.
62S&F in repairs CP Health Faucet with 1 mtr metalic Expandable tube & hook etc complete all as specified and directed.
63S&F in repairs for 15mm dia of pipe bib taps cast copper alloy, fancy type, chromium platedscrewed down, screwed for iron pipe or for brass ferrule and fixed etc complete all as specified and directed.
64S&F in repairbrass CP bib tap screwed down for iron pipe and fixed 15mm dia pipe fancy type etc complete all as specified and directed.
65S&F in repair brass chromium plated fancy shower rose 125 mm in size with or without swivel joints any size incl fixing to steel pipe or union etc complete all as specified and directed.
66S&F in repair angular stop cock CP with wall flange, fancy type 15 mm bore dia etc complete all as specified and directed.
67S&F in repair soap dish chromium plated stell/stainless steel, approx size 160x160mm x 1mm thick, fixed to walls with plugs & CP brass screws etc complete all as specified and directed.
68S&F in repairs 600mm long tubular tower rail brass chromium plated 20mm dia, D type 60cm longfixedwith two plugs (Gutties) of 2nd class hard woodembeded in cement mortor 1:3 with MS screws etc complete all as specified and directed.
69S& F in repairs 600 mm x 450 mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commerical plywood and fixed to wooden plugs with chromium plated brass screws and cup washers fancy type etc complete all as specified and directed.
70S&F in repairs CP toilet paper holder etc complete all as specified and directed.
71S&F in repairs corner glass shelf assembly 250mm radius made of 6mm thick craaylic glass, with CP railing, fixed with suitable rowal plug & screws etc complete all as specified and directed.
72S&F in repairs Rotational moulded polyethylene water storage tanks double layer with cover& 20mm ball valves high pressure of PTMT with epooxy coated aluminium road & high density plastic ball(cylindrical vertical with closed top) hoisted and fixed in position incl disconecting of existing tank all as specified in SSR Part I (Capacity in litres 1000) complete all as specified and directed.
73S&F in repairs vitreous china fancy wash basin, size 550 x 400mm white including brackets, and waste coupling & pipe of 32mm dia, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other and fixed etc complete all as specified and directed.
74Taking down cement plaster on brick walls including raking out joints hacking for key, scrubbing down with water etc complete all as specified and directed.
75M & L rendering 15 mm thick in cement mortar (1:6) on fair faces of brick or concrete work even and smooth without using extra cement etc complete all as specified and directed.
76M&L for rendering 15mm thick in CM (1:4) other than fair faces of brick work or concrete surfaces finished even and smooth without using extra cement etc complete all as specified and directed.
77M&L for preparation of newsurfaces of steel and iron work of any description over 10 cm width or girth not otherwise described andapplying two coats of synthetic enamel paint over a coat of redoxide primer on new surfaces in any tint etc complete all as specified and directed.
78M&L for preparation of old surfaces of steel and iron work of any description over 10 cm width or girth not otherwise described andapplying one coat of synthetic enamel paintin any tint etc complete all as specified and directed.
79M & L for preparation of newsurfaces of walls and applying two coats of oil bound distemperover one coat of chalk whiting etc complete all as specified and directed.
80M&L for applying two coats of oil bound distemper over one coat of primer over a coat of 3mm thick wall care putty on new plastered surfaces of walls including preparation of newsurface etc complete all as specified and directed.
81Material and labour for preparation of new external surfaces of walls including cornices, pillasters etc (Plastered or un plastered surfaces) and applying two coats of cement paint over a coat of primer complete all as per manufacture instructions etc complete all as specified and directed.
82M &L for preparation of old decorated surfaces of walls by washing, rubbing down and stopping of distempered surfaces and applying one coat of oil bound distemper of approved shade/tint etc complete all as specified and directed.
83Material and labour for preparation of old external surfaces of walls including cornices, pillasters etc (Plastered or un plastered surfaces) and applying one coat of cement paint including complete removal of existing surfaces all as per manufacture instructions etc complete all as specified and directed.
84M&L for preparation of newwooden fillets surfaces and wood based surfaces of any description not exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink wood primerin any tint etc complete all as specified and directed.
85M&L for preparation of old painted wood and wood based surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint in any tint all as specified and directed
86All as per item No 85.00 (here-in-before) but applying two coats of synthetic enamel paint over a coat of pink wood primer on new surfaces etc complete all as specified and directed.
87M&L for chequered cement concrete tiles 200x200x25mm thick laid over 15mm thick screed bed or bedding layer of mortar for laying floor finishes in cement mortar (1:6) etc, set, jointed and pointed in neat cement slurry with grey cement or no pigments etc complete all as specified and directed.
88M&L cement concrete type C-2, (1:3:6) (using 40 mm graded stone agg) as in surface channels and drains etc complete all as specified and directed.
89M&L for Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement incl firms mouldsetc complete all as specified and directed.
90M&L for 75 mm thick PCC 1:3:6 type C2 , using 40 mm graded stone aggregate in plinth protection/aprons/path laid to slope of 1:12, finished fair and even without using extra cement with and including all necessary formwork to divide tha area in panels, finishing exposed edges fair or rounding or chamfering where directed and providing 10 mm wide joints throughout thickness of plinth protection duly filled with mastic filling (one part of hot bitumen 85/25 and three part of fine sand by weight) complete all as specified and directed.
91S&F in repairsfor Draperly rod /Harrison rails of CP of 20mm dia with fixing brackets , stops, rollers and ringsetc complete all as specified and directed.
92Roughening surface of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and directed.
93M&L for non skid coloured joint free tiles 7 to 8 mm thick area of each tile exceed 0.18 sqm but not exc 0.38 sqm ,in floor etc. set and jointd in neat cement slurry and pointed in white or coloured cement to match the shade of tiles , laid over and including screed bed or bedding layer of mortar 15 mm thick for laying floor finishes CM (1:4) etc complete all as specified and directed.
94Resecuring or easing & adjusting , wthout taking down Shutter of any description exceeding 1 Sqm but Not exceding 2 Sqm each etc complete all as specified and directed.
95M&L for 2nd class hardwood Plain fillets Not exc 3 Sqcm. square, rectangular or triangular in section, clean sawn, secured with nails or brads.
96Excavating in post holes (or similar holes) each not exc 0.50 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n.exc 25cm, watering, and removing surplus soil to a distance n.exc 50 m and making good surface in soft/ loose soil etc complete all as specified and directed.
97M & L PCC(1:3:6) type C-2s(using 40mm graded stone aggregate) as in foundation etc and mass concrete etc complete all as specified and directed.
98S&Fsteelworkintubulartrusses, post, purlinsincludingspecialshapedwasheretc.CompleteusingERWorinductionbuttweldedtubesconformingtoIS1161-1979gradest-240 confirming to Fe 410-W (Gde E- 250) quality A complete all as specified and directed by Engineer - in – Charge
99S&F roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. confirming Fe-410-W(Gde-E-250) quality-A and painted one shop coat of zinc chromate primer paint (including preparation of surface) at contractors workshop before fabrication etc complete all as specified and directed.
100Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft and loose soil etc complete all as specified and directed.
101M&L for 75 mm thick Cement concrete type D- 2, (1:4:8), (using 40mm graded stone aggregate)as in sub base etc complete all as specified and directed.
102Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm etc complete all as specified and directed.
103Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point etc complete all as specified and directed.
104M&L for Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:4) using water proofing compound @ 3% by wt of cement for finished even and smooth without using extra cement (WPC will be measured and paid separately)etc complete all as specified and directed.
105Supply only Integral water proofing compound etc complete all as specified and directed.
106M& L for Preparation of new wall surfaces and applying Three coat white wash etc complete all as specified and directed.
107Taking down carefullycopper/ aluminium point wiring (light, fan, socket or power) complete, including fitting & fixtures such as switches with board, ceiling roses, pendents, bell/ buzzer, bell push, lamp holders, regulators, sockets, light fittings etc., removing material from site and making good to the disturbed surfaces of walls, ceiling,floors etc. including making good the disturbed surfaces and paint touch up to match with the existing surface complete all as specified and as directed.
108M&L for Point wiring complete with two runs of 1.5 sqmm single core PVC insulated FR-LSH cable1100 volts grade with multi-stranded copper conductors, drawn throughand including PVC double locked Casing & caping including provision of 1.5 sqmm, FR-LSH, PVC insulated copper cable as earth continuity conductor connected to common earth dolly, including PVC rectagular box for mounting switches / sockets / regulators etc. with 3 mm thick plastic laminated sheet cover of suitable size as required at site complete all as specified and as directed.
109(a) Onelight/Fan pointcontrolled by one, one way switch .
110(b) One 3 pin socket outlet 5 Amps on the same board with other switches.
111(c) One 3 pin socket outlet 5 Amps on the switch socket combination.
112All as per item No 109.00 here-in-before but with 2.5 Sq mm for 3 pin 15 Amps socket point controlled by one switch on independent board and 2.5 Sq mm copper conductor green in colour as earth continuity conductor connected to common earth dolly etc complete all as specified and as directed.
113M&L for Switch piano flush type single pole, one way 5Aetc complete all as specified and as directed.
114M&L for Socket outlet, 2 in 1, 5 pin 5A flush typeetc complete all as specified and as directed.
115M&L for Switch Socket combination, 2 in 1, 5 pin 6A flush type etc complete all as specified and as directed.
116M&L for Switch Socket combination, 2 in 1, 5 pin 6A/16A flush type etc complete all as specified and as directed.
117M&L for stepped type electronic fan regulator 100 Watt socket size flush type on the existing phenolic laminated sheet etc complete all as specified and as directed.
118M&L for ceiling rose 3 terminal PVC/Polycarbonate isolated body with PVC round/squareblock etc complete all as specified and as directed.
119Taking down existing burnt aluminium/ copper sub main wiring and M&L for sub main wiring with two runs of4 Sq mm and one run of 4 Sq mm for earth wire with multi standard copper conductors, 1100 volts grade, drawn throughand including PVC double locked Casing & caping including complete all as specified and as directed. NOTE:- two runs of 4 Sq mm + one run of 4 Sq mm and one run of PVC casing & capping and its accessories of suitable size shall be measured as one unit length .Make:- Finolex/Havells/RR KabelMake of caping/casing :- Prestoplast/Finolex/supreme
120Taking down S&F for LED Light fitting 1 x 20 watt (4 Ft), Wall/ Surface mounted, intergrated type with all accessories internally prewired and incl connecting up with 02 pvc blocks and incl twin/ three core twisted flexible copper conductor cable of suitable size in and incl flexible hose from ceiling rose to fitting complete all as specified and as directed. Make : Crompton Geaves Cat No -CCS-102-20-65-SL-DP-NWH/ Bajaj/ Philips.
121Taking down Supply , fixing and testing in replacement of LED Bldg Security light fitting of capacity 20 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including 1.2 mtr GI bracket of 25mm bore light grade bent to shape and fixed on wall with metal fastners 2 Nos 10mm dia incl drilling of holes as reqd and connecting up with flexible copper cable of size 0.75 sqmm 3 core from ceiling rose to the light fitting etc complete all as specified and as directed. : CG, Cat No- LSTS-20-CDL-M/ Bajaj/ Philips
122Supply and fixing round shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size etc complete all as specified and as directed.
123Supply and fixing LED luminaire 600 mm x 600 mm, 40/42 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size etc complete all as specified and as directed.
124M&L for VTPN 4 way double door 415 Volts, sheet steel, powder painted, with neutral link & earth bar etc and fixing MCBs of various rating capacity MCB DBs incl taking down of DBs etc complete all as specified and as directed.
125Supply and fixing MCCB 3 Pole 415 volts fixed type, 25 to 100 Amps with breaking capacity 16 KA complete with connection testing and commissioning etc complete all as specified and as directed.
126M&L for metal clad AC socket point single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB SP 20 Amps etc complete all as specified and as directed.
127M&L for MCB Distribution board double door type SPN 8 way, sheet steel, powder painted, withneutral link & earth bar etc. and fixing MCBs of various rating capacityincluding taking down old unsv MCB DBs etc complete all as specified and as directed.
128M&L for MCB SPN 32 Amps "C" series, 230 volts, 50 Hz suitable for fixing in MCB DBincl taking down old unsv MCB etc complete all as specified and as directed.
129M&L for MCB SP 6-32 Amps "C" series, 230 volts, 50 Hz suitable for fixing in MCB DB incl taking down old unsv MCB etc complete all as specified and as directed.
130M&L for MCB SP 40-63 Amps "C" series, 230 volts, 50 Hz suitable for fixing in MCB DB incl taking down old unsv MCB etc complete all as specified and as directed.
131Taking down Ceiling fan/ Exhaust Fan of any sweep carefully from its installed position, dismantling complete, cleaning all dust, applying grease for bearing, including filling cavaties with filler, after cleaning all dust, reassembling the fan and blades,hanging/ fixing the fan in its original position and testing on completion etc complete all as specified and as directed.
132Taking down LT UG cable/ service connection of any size and M&L for laying of LT UG cable, XLPE insulated, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of 25 sq mm, 3.5 core complete all as specified and as directed. NOTE :- (i) Excavation and earth work, sand cushioning, cable protection cover, pipe etc. shall be measured and paid seperately under relevant items.
133M&L for spread fine river sand in trenches complete all as specified ans as directed. NOTE: For measurement purpose, punned down thickness shall only be taken.
134M&L for laying brick sub class "B" old size burnt bricks for cable protection of size 230mmx115mmx75mm complete all as specified and as directed
135Supply & laying tubes "light grade" galvanised, with all fittings, fixed complete to walls, poles, ceilings or laid in floors/ trenches/ road crossing for protection of cables of size 40 mm dia bore including taking out unsv GI tubing complete all as specified and as directed.
136Material & Labour for earthing with galvanised steel earth plate electrode of size 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead wire 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified orindicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1, RCC (1:1.5:3) type A1 precast cover (54cmx54cmx5cm) duly reinforced with including 8 mm dia TMT bar @ 150mm c/c both ways, one lifting handle made of 8mm dia TMT bar, embeded in precast cover slab, funnel, 20mm dia GI medium grade watering pipe, 15mm dia GI light grade earth lead protection pipe, chorcoal and common salt in alternatee layer complete all as specified and directed by Engr-in-Charge.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy