Tender For Renovation Work For Administrative Office Building And Security Office At Elcot It Park Sholinganallur Chennai, Chennai-Tamil Nadu

Electronics Corporation Of Tamil Nadu Limited-ELCOT has published Tender For Renovation Work For Administrative Office Building And Security Office At Elcot It Park Sholinganallur Chennai. Submission Date for this Tender is 15-09-2023. Building Work Tenders in Chennai Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

39348293
Tender For Renovation Work For Administrative Office Building And Security Office At Elcot It Park Sholinganallur Chennai
Open Tender
Indian
Tamil Nadu
Chennai
15-09-2023

Tender Details

Renovation Work For Administrative Office Building And Security Office At Elcot It Park Sholinganallur Chennai

Key Value

Document Fees
INR 11800 /-
EMD
INR 33800.0 /-
Tender Value
Refer document

BOQ Items

Name of Work:
Sl. No. Item Description
1PART-A (CIVIL)
2Dismantling of existing plaster with cement mortar 20 mm thick in all floors etc., complete complying with standard specification and as directed by the ELCOT Officers
3Partition ProvidingsupplyingandfixingofGypsumBoardPartition madeby 50mm GI Floor and wall channels as horizontal members, 50mm GI Studs as vertical members to be fixed with screws and 600mm gap betweentwoverticalstobemaintained.Bothside12mmthickof Gypsum board to be fixed on GI frame. Joints on outer surface to be filledwithgypsumjointputty.Therateisinclusiveofcostof materials and labour charges.
4Providing UPVC (Un-Plasticized Polyvinyl Chloride) Door: Providing and fixing casement doors fabricated from un-plasticized polyvinyl chloride (uPVC) sections. Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mm x 55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steel reinforced with 25 x 24 x 25mm steel reinforcement with a thickness of 1mm to have dimensional stability. The sash should be of 60 x 102mm. The mullion should be of 60 x 74mm. The profiles should have co-extruded seals. Hardware: All the hardware like friction stays, handles should be screwed with self tapping screws. The handles, locks should be designed so that they cannot be released from outside. Glazing: The window system should be glazed with 5mm plain float glass / 6mm bison lam Installation: The profiles should be cut to length and welded 45 degrees. The window should be designed such that the water drainage does not pass through the reinforcement chamber. The window system should be fixed directly to the plastered brick wall using self expanding nylon plug and driving ms electroplated screws into plug.
5Supplying and painting the walls with two coats of oil bound distemper over one coat of water based cement primer including cost for distemper, primer, cleaning and scrapping the walls, rendering the wallssmooth with necessary putty, brushes, scaffolding arrangements, labour charges, etc., as per standard specification.(The colour and shade of the distemper shall be got approved by the Executive Engineer before use of work).
6Supplying and painting the Exterior walls with Texture Paint in New Work of Two or more coats applied @ 3.28 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20kg/10 sqm, cleaning and scrapping the walls, brushes, scaffolding arrangements, labour charges, etc., as per standard specification.(The colour and shade of the Texture shall be got approved by the Executive Engineer before use of work).
7Brick partition walls of 11.50cm thickness using best quality II Class Table Moulded Chamber Burnt Bricks of size 9" x 4-1/2" x 3" in Cement Mortar 1:3 (One Cement and Three Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately)
8Plastering with Cement Mortar 1:5 (One cement and Five sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers.
9Providing two layers of cement mortar plaster in cement mortar 1:5 (one cement and five sand), 20mm thick and making the surface smooth etc., complete complying with standard specifications.
10Providing new pannels fixing over the existing ACP Pannel with sealent joints for wall etc., complete complying with standard specifiction and as directed by ELCOT Officers
11Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work
12UPVC Ventilator Specification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work
13Solid PVC Door Shutters using 19 Gauge 19mm MS square tubes for styles and outer frames. 15mm MS square tubes for top, lock and bottom rails. The steel tubes shall be covered with 5mm thick solid PVC Sheets. Shutter using 5mm thick solid PVC Sheets for panelling shall rigidly fixed in position including necessary furniture and fittings. The over all size of styles shall be 50mm x 30mm. The over all size of top rail, lock rail and bottom rail shall be 75mm x 30mm. The over all size of frames shall be 50mm x 45mm with suitable rabate for housing the shutter etc., complete complying with standard specification and as directed by ELCOT Officers
14Supplying and filling in foundation, basement, etc with filling sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
15Cement Concrete 1:5:10 (One Cement, Five sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundationincluding dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification
16Supplying and fixing of colour Vitrified Tiles of size 600x600x8mm for flooring and other similar works (Best approved quality, colour and shade and the same shall be got approved from the Executive Engineer before use) in cement mortar 1:3 (one of cement and two of sand) 20mm thick including fixing in position, cutting the tiles to the required size wherever necessary pointing the jointswith grout ( Tile joint filler), curing, finishing etc., all complete and as directed by the departmental officers.
17Supply and providing 1000 litres capacity Priming Tank made up of PVC. Make: SINTEX / EQUIVALENT
18Supply, Installation, fixing,testing and commissioning of WHITE coloured vitreous china WALL MOUNTED EUROPEAN WATER CLOSET WITH open FLUSHING CISTERN with ‘P’or ‘S’ trap, andflush valve, complete with solid plastic seat with cover, C.P. hinges and rubber buffers, 15mm dia Angle stop cock with wall flange, 15mm dia C.P . cold water connection pipe including health faucet, 2 way BIB cock,24" PVC connection,5" grating noway, C.P.bolts and nuts etc,.The workshall includecuttingand making good the walls and floors etc. -In toilets. Model No
19Supplying and fixing in position best quality and approved make Indian made white / colour glazed earthernware wash hand basin of size 550 x 400mm (with pedestal / without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia "B" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers.
20Providing and fixing white vitreous flat back or wall corner type lipped front urinal basin (Get approval for model of Urinal item from architect)respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required:One urinal basin with 5 litre white P.V.C. automatic flushing cistern. details as per the dwg. Get approval
21Providing supplying and fixing of 6mm thick- Mirror (Saintgobain)with SS Studs (Ebco / Geze)with backply (Greenply BWR). The rate is inclusive of cost of material and labour charges. Details as per the dwg. Get approval from architect.
22Supplying and fixing of 110mm dia PVC SWR pipe with ISI mark conforming to IS 13952:1992- type "A"for Rain water down fall pipewith relevant specials such as gratings, shoes, bends, offsets conforming to IS 14735 includingjointing with seal ring conforming IS 5382 with leaving a gap about 10mm to allow thermal expansion with necessaryclamps, teak wood plugs, etc., of approved quality and including fixing C.I. gratings at the junction of parapet and floor or roof slab etc., including finishing etc., complete complying with relevant standard specifications.
23For the 110 mm dia
24Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications.(The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level
25For the 110 mm dia
26For the 75 mm dia
27Supply and fixing of PVC pipes with following dia etc., complete complying with standard specification and as directed by ELCOT Officers
2832 mm dia
2925 mm dia
3020 mm dia
31Supply and fixing in position 15mm dia brass CP Long body tap (heavy duty) of approved make conforming to BIS specifications and quality including cost ofshellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary. (Taps should be got approved by the Executive Engineer before use on the works)
32Supply and Fixing of Coat Hook Made up of SS. It should be got approved by Engineer"s Incharge before use on works etc., complete complying with standard specification and as directed by ELCOT Officers
33Supply and fixing in position best quality PVC 110mm dia providing leak proof joints including fixing to the wall with special PVC /MS clamps, etc., dismantling masontry / RCC works wherever necessary and making good the dismantled portion to the original condition, complying with standard specification etc., complete.
34CEO TABLE with Side Unit - measurement & finishes as per the dwg ProvidingsupplyingandfixingofCMD table unite to specifiedsize madetoshapeanddesign,butingeneralthetableshallbemadeof 18mmthickHDF fortopandadequatesupportsincrisscrossmanner, details asdirected/ shownindwg, all exposed surfacesshall be fixing with laminated finish. Rate shall be inclusive of providing two drawers and storages as per drg. detail, 50mm dia wire manager andwith necessary hardware"s and approved fittings like hinges, metal drawer slides, locking arrangement, handle etc., completed. Details as per the dwg
35STORAGE Units- measurement & finishes as per the dwg ProvidingsupplyingandfixingofCMD storage unit to specifiedsize madetoshapeanddesign,butingeneralthetableshallbemadeof 18mmthickHDF fortopandadequatesupportsincrisscrossmanner, details asdirected/ shownindwg, all exposed surfacesshall be fixing with laminated finish. Rate shall be inclusive of providing two drawers and storages as per drg. detail, 50mm dia wire manager andwith necessary hardware"s and approved fittings like hinges, metal drawer slides, locking arrangement, handle etc., completed. Details as per the dwg
36Executive Chair - Medium Back Twin Wheel Nylon Casters 5 Legs Prolonged Glass Filled Nylon Base Pneumatic Seat Height Adjustment Seat : Polyurethane Moulded Cushion with fabric upholstry
37Conference Table Chair - Medium Back Twin Wheel Nylon Casters 5 Legs Prolonged Glass Filled Nylon Base Pneumatic Seat Height Adjustment Seat : Polyurethane Moulded Cushion with fabric upholstry
38Electricals
39415V LT Panels Design, manufacture, testing at works, Supply, Installation, Testing and Commissioning of Indoor typeLTSwitchboards, Floor mounting type, Bottom/Top entry. Enclosure: Compartmentalized CRCA sheet with Single front, free standing, front hinged, rear removable, extendable on both sides, dust & vermin proof, cubicle type, floor mounted, undrilled gland plates at top/bottom Doors: 2mm Body: 2mm Gland: 3mm covers and partitions: 1.6mm with Neoprene gasket IP class:IP52 for Indoor/IP55 with weather proof enclosure for outdoor Bus bars: Electrolytic grade conductivity as per standard IS 5082 Bus bar Material: As per BOQ Bus bar supports: DMC/FRP/SMC Bus bar joints: Shrouded Protection releases: Adjustable over current & short circuit unless otherwise specified Ics=Icu for all breakers Loovers: Busbar chamber shall have louvers with fine mesh inside Shade: Epoxy powder coated RAL 7032 Bus bar insulation: Aluminum bus bars shall be bare with color coding at the ends
40Two dissimillar materials are joined with bi metalic washer. 1. The Panel shall be fully as per the requirement of Electrical Inspectorate / EB authorities. 2. All Breakers both incoming & Outgoing shall have LED"ON / OFF / TRIP"indications 3. CTs shall be cast resin type only. 4. All doors to have double rubber gasket with shutter assembly & door seating frame & Neoprane gasket shall be provided for all joints 5. AllMCCBsof 250A and above for non-ups loads willbemicroprocessor basedonly and for UPS panels shall be with thermal releases, and earth fault releases for above 250A Ratings. 6. The current density for Aluminium busbars shall be 0.8/sq.mm only. 7. The current density for Copper busbars shall be 1.2/sq.mm only. 8. All UPS outgoing panels shall haveneutral busbars double the size of phase & Lighting panels shall have equal Neutral size. 9.All meters shall beDigitaltype with RS 485 port only. 10. FRLS PVC copper wires shall be used for control wiring. 11. Multi function meter with suitable rated CTs should be provided for all incomer feeders as per mentioned in the Panel.
4112. All CTs should be provided for shorting link 13. Thebreakingcapacity of MCCB’s are mentionedpanelwise. All MCCB’s shall be with thermal magnetic releases below 250 amps and miroprocessor based above and including 250 amps capacity, unless specified otherwise. 14. All incoming and outgoing air circuit breakers shall be placed on middle portion of the vertical in single tier formation. 15. Elec. contractor have conduct a visit & access the elec. room in the site as before preparing the panel GA drawings & fabrication works.
42MAIN PANEL:
43Design, manufacture, testing at works, transportation to site, unloading, storing, leading, erecting, testing & commissioning of Main Panel suitable for 415Volts 3Phase 4 wire system, fabricated from 14/16SWG CRCA sheet steel, single fronted, free standing, front hinged, rear removable, extendable on both sides, dust & vermin proof, cubicle type, floor mounted, undrilled gland plates at top/bottom, complete with internal wiring, ferrules, name plates, painting etc., for panels & comprising of the following.
44Incomer - 1, 2 & 3 :
451 Set - 1 x 250A, 35KA, FP MotorisedMCCB (adjustable electronic overload & short circuit releases) with Electrical inter lock arrangements and associated protections MCB"s, R,Y,B Phase Indicating lamps & ON,OFF,TRIP for MCCB, auto/manual selector, & control circuit as required. (EB incomer) 2No x 63A, 25KA, FP MotorisedMCCB (adjustable electronic overload & short circuit releases) with Electrical inter lock arrangements and associated protections MCB"s, R,Y,B Phase Indicating lamps & ON,OFF,TRIP for MCCB, auto/manual selector,control circuit as required. (DG & solar) MAKE: ABB, SCINEDIER, SIEMENS
46Metering for Incomers - 1, 2 & 3 (Each) : 1Nos - 96sqmm MFM & Trip contact with RS 485 port 1set - Current Transformers(Cast resin type) 250/5A, 60/5 class 0.5, 10VA 1set - RYB LED type indication lamps for Phase 1set - RGA LED type indication lamps for ON/OFF/Trip 1Set - Class B+C SPD with control MCB Bus bar: 250A 4P, 35kA Aluminium Busbar.If the busbar is heat shrinkable sleeves with colour coded and SMC Bus bar supports. Current density of the bus bars shall not exceed 0.8A/sqmm. Electrical/Mechanical interlock (3Lock 1key) shall be provided for incomers. Outgoing: Section-I :
4763A, 25KA, TPN MCCB with front drive kit (adjustable electronic overload & short circuit releases), ON,OFF,TRIP indication lamps (etc,.) (Lift, solar, infra street light panel, spare)
48Section-II :
49160A, 25KA, TPN MCCB with front drive kit (adjustable electronic overload & short circuit releases)
50Outgoings of 63A 4P MCB (Floor wise DB"s, spare)
51Dismantling of old existing 4Nos of sub panels
52shifting the DG panels 2Nos form out side building to inside the building with required accessories.
53LT Cables & Terminations NOTES :- The Quantities (mtrs) given in the BOQ are only approximate and the contractor has to take actual measurements at site for the exact quantities of materials required before purchase of materials required for the work. Supply, laying, testing & commissioning of the following sizes of 1.1KV grade Aluminium / Copper Conductor armoured power cables Insulation of XLPE above 25Sqmm and Class A PVC below 25Sqmm laid on trays, ceilings, walls trenches, ground etc., with necessary clamps, cable ties, fasteners, identification tags, cable marking as required. Cost of sand, bricks, excavation should not be included in the rate quoted & measured separately. MAKE: HAVELLS, POLYCAB,FINOLEX
544C X 25 sqmm A2XFY
554CX2.5sq.mm YWY
564CX6 sq.mm YWY
57Supply & end termination of following AL/CU armoured power cables with necessary double compression brass glands, AL/CU. terminal sockets, insulation tapes, fasteners, earthing clips & connecting the clip to main earth bus with suitable bare copper wire complete accessories as required
584C X 25 sqmm A2XFY
594CX2.5sq.mm YWY
604CX6 sq.mm YWY
61Lighting wiring: Supply, Laying, Testing and Commissioning of 660/1100V grade FRLS multistrand copper wires, including termination on both ends with copper lugs in existing Wire ways / Conduits / Flexible. MAKE: HAVELLS, POLYCAB, FINOLEX
62Supply & laying of 2runs 2.5sqmm with 1run 1.5sqmm.for earthFRLS Copper Multistrand wire inside suitable MS conduit/ metallic flexible conduit in wall/ ceiling with all accessories required from DB to Primary Lighting circuit main / Sub circuits / Emergency etc.,
63Supply & laying of 2runs 4sqmm with 1run 2.5sqmm.for earthFRLS Copper Multistrand wire inside suitable MS conduit/ metallic flexible conduit in wall/ ceiling with all accessories required.,
64Supply, Installation, Testing and Commissioning of the following modular switches/sockets in aexisting MS BOX with necessary painting, earthing, making interconnection etc.,and necessary fixing arrangement on surface/recess of wall as required. MAKE: ANCHOR ROMA, SCINEIDER, LEGRAND
65SWITCHES
666A Switch 1W - 1 Module
676A Switch 2W - 1 Module
68SOCKETS:
6916A Switch 1W - 1 Module
7016A Socket 5 pin 1W Model
7120A Metal clad plug & Socket controlled by DP MCB for AC units
72Supply, installation of DB doors necessary fixing arrangement on surface/recess of wall as required.
73Supply, Installation, Testing and Commissioning of the following split units, making interconnection etc.,and necessary fixing arrangement on surface/recess of wall as required. MAKE: DAIKIN, LLOYD, SAMSUNG
741.5 ton
752 ton
76Supply, Installation, Testing and Commissioning of the following MCB in Existing DB"s, earthing, making interconnection etc.,and necessary fixing arrangement on surface/recess of wall as required. . Note: The MCB,s are "D" Curve only. MAKE: ABB, SCINEIDER, LEGRAND
7710A - 32A SP MCB
7810A - 32A DP MCB
7916 A - 32A TPN MCB
8010A - 32A 4P MCB
8110A - 25A DP 30mA RCCB
8210A - 25A DP 30mA RCBO
8340A DP 30mA RCCB
8440A DP 30mA RCBO
85Supply, Installation, Testing and Commissioning of the following MCB in asuitable MS enclosure with necessary painting, earthing, making interconnection etc.,and necessary fixing arrangement on surface/recess of wall as required. . Note: The MCB,s are "D" Curve only.
8610A - 32A SP MCB
8710A - 32A DP MCB
8810A - 32A TP MCB
8916 A - 32A TPN MCB
9010A - 32A 4P MCB
9110A - 32A DP 30mA RCCB
9210A - 32A DP 30mA RCBO
93LIGHT FIXTURES / CEILING FANS Supply and fixing of the below mentioned light fixtures with all standard accessories including lamp, Installation, testing and commissioning of the same as per the lighting layout drawings complete with all other accessories such as down rods / suspension rods / frames, anchor fasteners, necessary hardware etc. MAKE: PHILIPS, HAVELLS, WIPRO, CROMPTON
94Similar to philips cat.no.WT150C LED27S-6500 PSU L120 20W.
95Ressed/ square/round Mounted downlighter - Similar to philips cat.no. ?SM360B LED20S 6500 L30W30 PSU OD (Surface mounted LED 1X1 20W, 2000 lumens, IP20)
96Similar to philips cat.no. RC360B LED20S 6500 L30W30 PSU OD (Recess mounted 1X1 20W, 2000 lumens, IP20)
97?Similar to philips cat.no.RC380B LED25S-6500 G6 L60W60 PSU OD (Recess mounted LED 2X2, 20W, 2500 lumens, IP20)
98?Similar to philips cat.no. RC380B LED25S-6500 G6 L60W60 PSU OD with surface frame.
99Similar to philips cat.no.BN100C LED40S-6500 PSU L120 GR S4 34W.
10048"ceiling fans with regulator
101EARTHING SYSTEM Supply & erection of 100mm dia Cast Iron earth electrode of 10" length buried in ground as per IS with necessary connecting clamps, watering arrangement &fasteners etc. The pit shall be filled with alternate layers of salt &charcoal. The rates shall include excavation of the pit, construction of masonry chamber, providing heavy duty concrete cast slab, painting & making etc., & as per the technical specification.
102Design, supply and laying of 25 x 3 mm GI flat for panel earthing as required.
103Design, supply and laying of 8 gauge bare copper wire for equipment and DB earthing as required..
104No "14" SWG Copper rounds for Gland earthing, loop earthing in the existing surface/recessed PVC conduit, and other equipment loop earthing as required.
105Earth work excavation in soil/soft roock/hard rock/ soft disintegrated rock for the required width 300mm and depth 600mm.The rate shall include refilling compacting and making of good surface to match with the original FGL. After laying the Cables, sand filling to protect the cable including brick layer. Supplying and laying good quality river sand to a depth of 75mm below cable and also one layer of 75mm river sand above cable. The rate shall include good quality bricks of size 230mmx100mm laid over the sand cushion layer to protect the cables.
106ELECTRICAL ROOM EQUIPMENTS Supply & fixing of Shock Treatment chart in Tamil & English languages duly laminated/ glass framed
107Supply & fixing of Rubber mats of size 2m x 1m x 2mm to 3mm thickness & confirming to IS 15652/2006 and laying in front of panels & Proper clamping for four side as per site required (Suitable size of LV & HT)
108Supply & fixing of First aid box of Thadani make containing full compliment of medicines, ointments & bandages etc.,
109Supply & fixing of CO2 type fire extinguisher 4.5Kg or equivalent approved make with ISI mark including necessary fixing brackets
110Supply & fixing of cast iron LT cable route markers (round shape) with necessary angle iron supports & civil works as per site requirement.
111Supply & fixing of 230V, AC portable & re chargeable emergency light with 15W LED lamp of BPL/Panasonic Make
112Supply & Fixing of A0 size colored As fitted Single line drawing duly laminated / framed in electrical room
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy