| 1 | Addition /Alteration to Utility room for Wind tunnel at Ist floor bldg No.P/38 Directorate of Aerodynamic Testing (DOAT) AT DRDL, HYDERBAD. |
| 2 | Demolition ofstone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 3 | Demolition of cement concrete nominal concrete 1:3:6 or richer mix (i/c equivalent design mix manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 4 | Dismantling doors, windows and clerestory windows (steel or wood) shutter of area 3 sq. metres and below including chowkhats, architrave, holdfasts etc. completeand stacking within 50 metres lead complete all as specified and as directed. |
| 5 | M&L Brick work with flyash F.P.S. (non modular) brick of class designation 7.5 in superstructure above plinth level up to floor five level in Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 6 | M&L Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in cement mortar 1:4 (1 cement : 4 coarse sand) |
| 7 | M&L for 15 mm cement plaster in 1:4 (1 cement : 4 fine sand) |
| 8 | M&L for 15 mm cement plaster in 1:6 (1 cement : 6 fine sand) |
| 9 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 10 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade onNew work (two or more coats) over and including water thinnable priming coat with cement primer |
| 11 | M&L White washing with lime to give an even shade on New work (three or more coats) |
| 12 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth. Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives on New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm complete all as specified. |
| 13 | Providing and laying Ceramic glazed floor tiles of size 300x300 mmor more(thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 14 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete |
| 15 | Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, Providing and fixing factory made P.V.C. door frame of size 50x47 mmwith a wall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer’s specification and direction of Engineerin-Charge |
| 16 | Providing and fixing to existing door frames 30 mm thick factory made Polyvinyl Chloride (PVC) door shutter made of styles and rails of a uPVC hollow section of size 60x30 mm and wall thickness 2 mm (± 0.2 mm), with inbuilt decorative moulding edging on one side. The styles and rails mitred and joint at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 25x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of \"H\" section, a uPVC hollow section of size 100x30 mm and 2 mm (± 0.2 mm) wall thickness fixed to the shutter styles by means of plastic/ galvanised M.S. \"U\" cleats The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness . The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer\"s specification and direction of Engineer-in-charge. |
| 17 | Powder coated aluminium (minimum thickness of powder coating 50 micron) fixed portion |
| 18 | Powder coated aluminium (minimum thickness of powder coating 50 micron) shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) |
| 19 | Providing and fixing 12 mm thick prelaminated particle board with decorative lamination on both sidesflat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineerin-charge |
| 20 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) , EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item) |
| 21 | Providing and fixing 100x75x3.50 mm ISI marked, IS : 1341, M.S. heavy weight butt hinges with necessary screws etc. complete |
| 22 | Providing and fixing 150 x 10 mm aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete |
| 23 | Providing and fixing 125mm aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete |
| 24 | Providing and fixing 15 mm dia nominal bore G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall : |
| 25 | Providing and fixing 20 mm dia nominal bore G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall : |
| 26 | Providing and fixing 20 mm nominal bore gun metal gate valve with C.I. wheel of approved quality (screwed end) |
| 27 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require , White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap |
| 28 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid |
| 29 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required , Single half stall urinal with 5 litre P.V.C. automatic flushing cistern |
| 30 | Providing and fixing 15mm nominal bore C.P. brass bib cock of approved quality conforming to IS:8931 |
| 31 | Providing and fixing 15mm nominal bore C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931 |
| 32 | Providing and fixing square-mouth S.W. gully trap class SP-1 180x150 mm size P type complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 33 | Providing and fixing soil, waste and vent pipes 100 mm diameter Sand cast iron S&S pipe as per IS: 1730 |
| 34 | Providing and fixing plain bend of required degree 100 mm diameter Sand cast iron S&S pipe as per IS: 1729 |
| 35 | Providing and fixing uplasticised PVC connection pipe with brass unions 15 mm nominal bore 45 cm long. |
| 36 | Providing and fixing PTMT grating circular type of approved quality and colour 125 mm nominal dia with 25 mm waste hole. |
| 37 | Providing and fixing PTMT towel rail 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour |
| 38 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screwsProviding and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 39 | Provn of Hard standing at 2D Supersonic wind tunnel (Building No - 102/1) and Compresser building P-39 for DOAT ,Hyderabad. |
| 40 | Earth work in all kind of soils excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge |
| 41 | Removing excavated soil to a distance n.exceeding 50mand depositing where directed at level n.exc 1.5m above starting pontcomplete all as specified and directed |
| 42 | P & L 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 43 | Supplying and stacking at site. 90 mm to 45 mm size stone aggregate for solling of road. |
| 44 | Cement concrete pavement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete. |
| 45 | Extra for making chequers of approved pattern on cement concrete floors, steps, landing, pavements etc. |
| 46 | PROVISION OF BOREWELL WITH SUPPLY, CREATION COMMISSIONING OF SUBMERSIBLE PUMP LAYING OF P/LFOR PROVISION OF GRASS GROUND AT DMRL , HYDERABAD. |
| 47 | Surveying the area by specialist agencies to locate points with electro location resistive method for drilling 150mm Dia bore well |
| 48 | Drilling of borewell 150mm dia in any type of soil including rock granites up to the following depths at one specified point including all labour material and equipment |
| 49 | Up to 30m |
| 50 | 31 to 60m |
| 51 | 61 to 100m |
| 52 | 101 to 130m |
| 53 | 131 to 160m |
| 54 | Providing PVC blue casing pipe heavy duty sloked/plane (10 kg/sq.cm) of 150 mm dia in bore well conforming to IS : 2818 |
| 55 | Supply, errection, testing and commissioning of submersible Pump Set 7.5 HP 10 stage with ISI mark |
| 56 | Supply and laying GIpipe medium grade 50 mm dia 3meter pipescomplete all as specified and as directed. |
| 57 | Supply, errection, testing and commissioning of 2.5 sqmm 3 core copper cable flat water proof inside borewell and laid over ground suitable for submersible pump along with PVC conduit where required all complete |
| 58 | Supply and laying 3 core 16 sqmm and PVC under ground cable with end terminating including excavation of soil with protection back filling etc., complete as per IS specification. |
| 59 | Supply, errection, testing and commissioning of control board including DOL/Star starter (L&T) main switch single phase preventer voltmeter, ammeter, selection switch indicator lamps suitable for fixing in MS box including GI pipe earthing as per IS 3043 etc., complete. |
| 60 | Providing HDPE pipe PE-63 grade (12.5 kg/sq.cm) of 63 mm OD mm dia. |
| 61 | Supply and fix CI non return valve of63 mm bore diaconforming to IS 5312 both end flanged and including necessary fixing arrangement as required at site by providing rubber/fibre gasket ,nuts, bolts & washers etc complete |
| 62 | Supply and fix new gun metal gate valves with iron wheel head screwed on both ends for iron pipe with necessary GI fittings of the size 63 mm dia. |
| 63 | M&L for PEA gravel 3mm to 6 mmfor packing/ filling the gap between drilled hole and bore casing pipe complete all as specified and directed |
| 64 | EXTERNAL ELECTRICAL CONNECTION TO HIGH PERFORMANCE CLUSTER (HPC) ROOM. |
| 65 | Laying only one number PVC insulated and PVC sheathed / XLPE power cable of 1100 V grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 66 | 120 sq. mm. |
| 67 | Supply only cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 1100 volts grade, of size 3.5 core as mention below . |
| 68 | 120 sqmm |
| 69 | Earthing with copper earth plate 600 mm x600 mmx 3mm thick including accessories, and providing masonary ensure with cover plate having locking arrangement and watering pipe of 2.7 metrelong etc. with charcoal/coke and salt as required |
| 70 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 71 | Labour and material for road cutting, laying of HDPE pipe of 100mm dia and refilling the excavated material and PCC the cutting portion with 1:2:4 PCC all as directed by Engineer in charge |
| 72 | Supply and fixingfour pole, 415 VMCCB 125Amp 50 KA capacity complete with connections, testing and commissioning all as specified |
| 73 | Supplying and fixingsheet metal enclosure on surface/ recess mounted for 125 Amps MCCB complete with connections, testing and commissioning specified |
| 74 | REPLACEMENT AGAINST BER CEILING FANS, EXHAUST FANS, WALL MOUNTED FANS AND PEDESTAL FANS AT DRDL UNDER GE (I) R&D KANCHANBAGH HYDERABAD. |
| 75 | S&F ceiling fan of sweep 1200mm, 240volts, not less than 26 Watt,5 star BEE rating & without remote control , BLDC dust resistant fan connecting up with three core 1.0 Sqmm cable from ceiling rose with required length of down rod as required at site including taking down of old ceiling fans all as specified. NOTE:- (i) Taking down existng ceiling fan and deposit to the MES store yard with in the AOR.(ii) Stencil Mark MES number on ceiling fan motor. |
| 76 | Supply and fix exhaust fans AC single phase 230/240volts of size 300mm sweep heavy duty with louvers inlcuding taking down of old exhaust fans. NOTE:- (i) Taking down existng exhaust fan and deposit to the MES store yard with in the AOR.(ii)Stencil Mark MES number on exhaust fan motor. |
| 77 | Supply and fix exhaust fans AC single phase 230/240volts of size 380mm sweep heavy duty with louvers inlcuding taking down of old exhaust fans.NOTE :-(i) Taking down existng exhaust fan and deposit to the MES store yard with in the AOR.(ii)Stencil Mark MES number on exhaust fan motor. |
| 78 | Supply and fix exhaust fans AC single phase 230/240volts of size 450mm sweep heavy duty with louvers inlcuding taking down of old exhaust fans. NOTE :- (i) Taking down existng exhaust fan and deposit to the MES store yard with in the AOR. (ii) Mark MES number on exhaust fan motor. |
| 79 | Supply & fix metalic heavy duty Air Circulator fans 230 volts single phase oscillating 450 mm sweep suitable for wall mounting including taking down of old Air circulator fans. NOTE :- (i) Taking down existng Air Circulator fan and deposit to the MES store yard with in the AOR. (ii) Mark MES number on Air Circulator fan motor. |
| 80 | Supply and Fix Pedestal fan 450 mm sweepwith high air delivery aerodynamically designed 230V, 50Hz complete all as specified and directed. NOTE :- (i) Taking down existng pedestal fan and deposit to the MES store yard with in the AOR.(ii) Stencil Mark MES number on pedestal fan motor. |
| 81 | PROVISION OF CERTAIN WORKS IN TITANIUM ALLOY GROUP (TAG) BUILDING No.52 OF DMRL,HYDERABAD. |
| 82 | Demolition ofcement concrete manually / by mechanical means including disposal of materials within 50 metres as per direction of Engr -in- Charge |
| 83 | Excavation work in ordinary soil by mechanical means ( hydraulic excavator) / manual means in foundation trenches or drains ( not exceeding 1.5m in width or 10 sqm on plan) incluindg dressing of sides and ramming of bottom lift upto 1.5m incluindg getting out the excavated soil and disposal of surplus excavated soils as directed within a lead of 50 mtr |
| 84 | Providing and laying 1:4:8 ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size derived from natural sources) in position cement concrete of specified grade excluding the cost of centering and shuttering. All work upto plinth level |
| 85 | Providing and laying in position A1 type 1:11/2:3 cement concrete work using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolanna / Ordinary Portlamd / portland slag cement admixtures in recommended proportions as per IS : 9103 to accelerate / retard setting of concrete , to improve durability and workability without impairing strength incluidng pumping of concrete to site of laying, curing, carriage for all leads, but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engr-in- Charge for the collowing graded or concrete all works upto plinth level . |
| 86 | Centering and shuttering including strutting, propping etc and removal of form for Foundations, footing, bases of columns etc |
| 87 | Steel reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - MechanicallyTreated bars of grade Fe- 500D or more |
| 88 | Brick work with common burnt clay F.P.S ( non modular ) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in cement mortar 1:4 complete |
| 89 | 15mm thick rendering in CM 1:6 on fair faces of brick work or concrete surfaces and finished the surface fair and even without using extra cement complete . |
| 90 | 6mm thick cement plaster 1:3 ( 1 cement : 3 fine sand) on ceiling surface finished with a floating coat of neat cement and thick coat of lime wash on top of ceiling when dry for bearing of RCC slabs and beams |
| 91 | Distempering Two or more coats on new workwith Ist quality acrylic distemper , having VOC ( Volatile Organic Compound) content less than 50 grams / litre of approved brand and manufacture of required shade and colour complete as per manufacturer\"s specification. |
| 92 | White washing on new work ( three or more coats) with lime to give an even shade. |
| 93 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate Z sections and other sections of approved make conforming to IS : 733 and IS : 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions i.e at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium section shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling CP brass/ stainless steel screws, all complete as per architectural drawings and the directions of engr -in- Charge. (Glazing, paneling and dash fasteners to be paid for separately) :-(i)For fixed portion powder coated aluminium ( minimum thickness of powder coating 50 micron) |
| 94 | All as per above butFor shutters of doors, windows & ventilators powder coated aluminium ( minimum thickness of powder coating 50 micron)including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required incluindg the cost of EPDM rubber/ neoprene gasket required ( Fittings shall be paid for separately) |
| 95 | Proving and fixing glazing in aluminium door, window, ventilator shutters and partitions etc with EPDM rubber / neoprene gasket etc complete as per the architectural drawings and the directions of Enginer-in-charge:-(i)With float glass panes of 5mm thickness ( weight not less than 12.50 Kg/ Sqm) |
| 96 | Making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sandderived from natural sources : 6 graded stone aggregate 20mm nominall size derived from natural sources) of 75mm thick bed of dry brick ballast 40mm nominal size, well rammed and consolidated and grouted with fine sand , including necessary excavation, levelling & dressing & finishing the top smooth. |
| 97 | Disposal of building rubbish / malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer -in- charge beyond 50m initial lead for all leads incluidng all lifts involved. |
| 98 | Demolishing brick work in cement mortarmanually / by mechanical means includng stacking of serviceable materials and disposal of unserviceable materials within 50 meter leads as per direction of engr -in- Charge |
| 99 | Steel work in built up tubularhot finished welded type tubes ( round, square or rectangular hollow tubes etc) trusses etc including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer incluidng welding and bolted with special shaped washers etc complete |
| 100 | Providing and fixingsteel work in gratings, frames, guard bars, ladders, railing, brackets, purlings, gates and similar workswelded in built up sections / frames work, incluidng cutting, hoisting, fixing in position and applying priming coat of approved steel primer using structural steel as required |
| 101 | Providing and fixing 0.56mm aluminium color coated profile with centre to centre pitch of 175mm , depth of 46mm, top crest width of 41mm, bottom valley width of 80mm overall profile width of 1144, cover width 1050mm at all height, levels and locations colour finish aluminium alloy roofing sheets of alloy IS designation 31500, temper H x8 conforming to IS 737 and dimensions as per IS code 2676 with characteristics of good formability and corrosion resistance. |
| 102 | Painting on new steel surface ( two or more coats ) incluidng a coat of approved steel primer ( red oxide primer)with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade |
| 103 | Providing and fixing 1mm thick MS sheet door with frame of 40 x 40 x 6mm ange iron and 3mm M.S gusset plates at the junctions and corners, all necessary fittings complete including applying a priming coat of approved primer using MS angles 40 x 40 x6mm for diagonal braces complete |
| 104 | Providing and laying cement concrete in retaining walls, return walls ( any thickness) incluidng attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, sunken floors etc upto floor five level excluding the cost of centering shuttering and finishing :- (i)1:2:4(1 cement : 2 coarse sand ( zone -III) derived from natural sources : 4 graded stone aggregate 20mm nominal size derived from natural sources ) |
| 105 | Providing and fixing 12.5mm thick tapered edge Glass reinforcedGypsum board conforming to IS : 2095 (Part 3) : 1996false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from MS sheet and galvanised with zinc coating of 120gms/ sqm ( both side inclusive ) as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm at 1200mm centre to centre, one flanges fixed to the ceiling with dash fastener 12.5mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25 x 10 x,50mm of required length with nut & bolts of required size , Gypsum board of 12.5mm thick with white paper layer on face side of size 600 x 600 mm as directed |
| 106 | Supply and install 2 Ton inverter type,5 Star rated AC\"s with Low Gas Indication,Clean filter Indication, Automatic installation check and turbo cool with Auto cut -off feature complete all as directed. |
| 107 | Supply and fix Voltage stabilizer copper wound for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5KVA |
| 108 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required for 2x4 sq. mm + 1x4 sq. mm earth wire |
| 109 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \"C\" curve DP MCB complete with connections, testing and commissioning etc. as required |
| 110 | S&F in walls/roofs PVCPipe 20 mm heavy duty for Condensing water line including making provision for fixing. |
| 111 | S&F in walls/roofs PVCPipe40 mm heavy duty for Condensing water line including fittings and making provision for fixing. |
| 112 | M&L for insulation only to copper tubing of split type AC of cap 2.0 TR with heavy duty rubber foam insulation as per existing density and thermal conductivity including packing material, reflactor tape and pvc tie complete all as specified and directed.Make- Armaflex / Aeroflex / Thermobreak |
| 113 | S&F inflexible type water drain out pipe suitable forindoor unit of split AC as per existing type/model complete all as specified and directed. |
| 114 | S&F Copper pipes 1/4 to 1/2\" dia, duly insulated with synthetic felt tube, for split / window type Airconditioner / refrigerator / water cooler complete with taking out old unserviceable one |
| 115 | All as per item No 109above but of size 3/8 to 5/8\" dia |
| 116 | S&Fin replacement Brass flair nuts 1/2 to1/4\" including taking out old unserviceable one. |
| 117 | All as per item No 112above but of size 3/8 to 5/8\" dia |
| 118 | PVC insulated 3 core round flexible copper cable 1100 v grade of size 4.0 sq mm Make:- Plaza/Polycab/Havells/Finolex |
| 119 | PVC insulated 3 core round flexible copper cable 1100 v grade of size 2.5 sq mm Make:- Plaza/Polycab/Havells/Finolex |