| 1 | ???, ???,?????? ??? 1.5 ????? ?? ?????? ?? ????? ???? , ?? ?? ????? , ???? ?????, ??? ?? ??????? , ???? ?????? ?? ???? ???????, ??? ???? ?? ??? ???? ???????? ?? ???: ?????? ?? ???? ??? ??? ??? ????? ?? 50 ???? ?? ???? ?? ????????? ???? ?????, ?????,???? ?????? ??? |
| 2 | ???????? ???????? ???? ?? ???? ??? 40 ??.??. ????? ??? ?? ??????? ??????(crusher broken)/?? ????? , ????????- ??? ????? ??? 1 ???????? : 4 ??? : 8 ?????? ?????? ??? ????? ??? ????? ???? , ???? ???? ? ) |
| 3 | ?????? ??????? 1:1.5:3 ?????? ?? ??????? ?????? ??????? ??? ????? ??? ??????? ????, ?? ?? ??????, ??????, ???, ????? ??? ??? ?????, ???? ???? ??? ??? ?? 1:3 ?????? ????? ?? ???? ???? ??? ???? ???????? ???? ??????? ?????? ??? ?????? ?? ???? ??? ??? |
| 4 | ??????????\"?????? (????? ??? ????????) ?? ??.??.??. ??, ??????, ??????, ??????? ??? ????? ?? ??? ????? 4.5 ???? ???? ?? ?? ??? ??? ????? ??? ????? ????? ?? ??????? ?????? ????? |
| 5 | ??.??.??. ??? ?? ??? ???? ?? ?????, ?????? ??? ?????? ?? ????? ??? ?????? ?? ????? ?? ??????? ?? ? |
| 6 | ???? ??? ?????? ??? ?????? ?? ?? ?????-???? ??????-???? ????? ???, ?? ??? ?? ???? ????? ???? ??? ???? ??? ????? ?????? ???? 1:6 |
| 7 | ????? ?? ??????? ???? up to 1 km lead |
| 8 | ???? ??? ??????/??? ?? ??? ??? ??? ?????? ??? 50 ???? ?? ???? (Lead) ??? ????? ??? ???? ???? , ???? ????? ??? ?????? ?? ?????? |
| 9 | ???? ?? ???? ???? ????? ???? 15 ???? ???? ???????? ?? ??????? ??? ????? ????? ?? ????? ?????? |
| 10 | ??????? ??? ????? ?????? ??? ?? ????? ???????? -???? 1:6????? ???, ?? ??? ?? ???? ????? ???? ??? ???? ????? |
| 11 | ?????? ?????????? ????? ?? 1:6 ?????? ??? ??????-???? ?????? ?????? ?? ??????? ??? 14 ??? ?? ?????? ???? ????? 20 ??.??. ????? |
| 12 | ?????? ?????????? ????? ?? 1:6 ?????? ??? ??????-???? ?????? ?????? ?? ??????? ??? 14 ??? ?? ?????? ???? ????? 12 ??.??. ????? |
| 13 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding:Newwork(twoormorecoats)overandincludingscrappingandprimingcoatwithcement primer. |
| 14 | Finishing walls with Acrylic Smooth exterior paint of required shade including all scaffolding. New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm ). |
| 15 | ???? ??? ?? ?????? ????? ?????? ?? ?????? ?? ??????? ???? ??? ?????????? ?? ??? ?????? ?????? ?? ????? ??? ?????? ??? ???? ?????? ????? (?????????? ?? ???? ????? ???? ??)? Virtified ?????? Size 60 X 60 cm |
| 16 | 20 ???? ????? ??? 1:4 ?????? ???? ????? ?? ??? ????? ???? ?????? ????, ???????? ?? ????? ? ????? (??????? 3 ???)??? ?????? ?? ?????? ?? ??? ?? ?? ?? ?????? ????2300 ???? ???? ?? ???? |
| 17 | Providing and fixingaluminum workfor doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285,fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and thedirections of Engineer- in – charge .(Glazing and paneling to be paid for separately). For shutters builtup standard tubular sections of openable doors ,windows & ventilators including providing & fixing hinges / rollers etc. and making provision for fixing of fittings wherever required (lockes shall be paid for separately)Polyester Powder coating aluminum( minimum thickness of powder coating 50 micron) . Extra for shutters of slidingaluminum windows |
| 18 | Providing and fixing to existing door frames 24mm thick factory made PVC door shutters made of stiles and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2mm +/- 0.2 mm with inbuilt edging on both sides.The stiles and rails mitred and joined at the corners by means of M.S.galvanized/plastic brackets of size 75x220mm having wall thickness 1.0mm+/- 0.1mm and stainless steel screws. The stiles of the shutter reinforced by inserting galvanized M.S.tube of size 20x20mm and 1mm +/-0.1mm wall thickness. The lock rail made up of ‘H’ section,a uPVC hollow section of size 100x24mm and 2mm +/- 0.2mm wall thickness fixed to the shutter stiles by means ofplastic/ galvanized M.S.’U’ cleats.The shutter framefitted with a uPVC multi-shambered single panel of size not less than 610mm, having overall thickness of 20mm and 1mm +/- 0.1mm wall thickness. The panels fitted vertically and tie bar at two places by inserting horizontally 6mm galvanized M.S.rod and fastened with nuts and washers, complete as per manufacturer’s specification and direction of Engineer-in-charge (For W.C.and bathroom door shutter). |
| 19 | Providing and fixing 12 mm thick prelaminated three layer medium density (exterior grade ) particle board Grade I, Type II conforming to IS : 12823 bonded formaldehyde synthetic resin ,of approved brand and manufacture in paneling fixed in aluminium doors ,windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and direction of engineer-in-charge. Prelaminated particle board with decorative lamination on both sides. |
| 20 | Providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with PVS / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basicitem.) With float glass panes of 8 mm thickness |
| 21 | 50 ???? ????? ??? ?????? ??????? 1:2:4 ?????? ?????? 1 ?????? 2 ???? 4 ?????? ?? ?? ??? ?? 12 ??. ????? ?????? ?? ??? ?????? ?????, ?????, ????? ??? ???? ??? ????? |
| 22 | Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete. Jhunjhunu / Jalore (Red/Choclate/Black/Pink Colour) 1501 Cm2 to 3600 Cm2 Tiles |
| 23 | SANITARY WORK ( from pwd building bsr 2019) |
| 24 | ???????? (?????????.??.) ?? ???????? ? 100 ???? ?? ?? ?? ?????? (?????) ????? ???? ? ?????? ???? ???? ???? ?????? ?? ???????? (?????????.??.) ???? 530X410 ???? ? |
| 25 | ???? ??? ???? ?? ??????? ?? ????? ??? ???? ???? ???? ???? ???? ?????? ?? ??????, ?????????(???? 430X350X300 mm) , ???? ??????? ??? 25 ???? ?? ?????? ???? ?? ???? ????? ??? ?????????? ????? |
| 26 | 450X300 ???? ???? ?? ???? ???? ???? ?????? ?? ??? ???? (????????) ?? ?????? ???? ?????? ?????? ???? ???, 15 ???? ?? ????? ??? ??? 32 ???? ?? ???? ????? ?????? ?????? ??? 25 ???? ?????? ?? ?????? ???? ?? ?????? ???? ????? ? ?????????? ????? |
| 27 | ???? ??? ?? ?????? ????? ?????? ?? ?????? ?? ??????? ???? ??? ?????????? ?? ??? ?????? ?????? ?? ????? ??? ?????? ??? ???? ?????? ????? (?????????? ?? ???? ????? ???? ??)? ??????? ?????? Size 30 X 45 cm |
| 28 | Providing and fixing 3-layer PP-R (Polypropylene random coplymer ) pipes SDR 7.4 UV stabilized and antimicrobial fusion welded, having thermal stability for hot & cold water supply including all PP-R plain & brass threaded Polypropylene random fittings and fixing the pipe with clamps at 1.00 spacing. This includes testing of joint complete as per direction of Engineer - in charge.( INTERNAL WORK- EXPOSED ON WALL) |
| 29 | PN-16Pipe, 25 mm OD |
| 30 | PN-16Pipe, 40 mm OD |
| 31 | Construction of septic Tank in all types of soil with 40 Cm .thick masonry in CM 1:6, 15 Cm thick C.C bed of 1:5:10, M-15 gradeC.C floor &RCC slab covering with M15 grade c.c. floor,50 mm thick stone slab partition walls, 20 mm thick plaster in CM 1:6 finished with neat floating cement, 4 Nos stone foot rests of approved design ,two No. 450 mm dia each Ferro cementcover with frame, earth work etc. complete as per approved drawing including disposal of surplus earth within a lead of 50 mtr:-Size 230 x110 x150 cm.(for 20 users) |
| 32 | P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make: |
| 33 | C.P. Brass Long body, 15mm nominal bore weight not less than 690 gm |
| 34 | Providing and fixingSuperior quality (Jaguar Contiental ) CP Brassfittings complete as per direction of EI |
| 35 | Pillar Cock 15 mm nominal size |
| 36 | P&FFlushCock / FlushValve (IS :9758Mark)forWCofapproved quality make : CP brass push type exposed 25mm nominal bore. |
| 37 | P&FPVC water tank |
| 38 | ELECTRIC WORK(Based on PWD Electric BSR 2013) |
| 39 | Wiring of light point/fan point/exhaust fan point/cell bell point with 2X1.5 Sq.mm FR PVC insulated unsheathed flexiable conductor 1.1 KV grade making connections ,testing etc. as required |
| 40 | Short Point (up to 3 Mtr) |
| 41 | Medium Point (up to 6 Mtr) |
| 42 | Long point (up to 10 Mtr.) |
| 43 | Wiring of twin control light point with 1.5 sq.mm Fr PVC insulated unsheathed flexible copper conductor 1.1 KV grade and 1.5 sq.mm FR PVC insulated unsheathed flexiable earth conductor with screws,cup washers,making connections ,testing etc. as per required. |
| 44 | Short Point (up to 3 Mtr) |
| 45 | Medium Point (up to 6 Mtr) |
| 46 | Long point (up to 10 Mtr.) |
| 47 | Providing & Fixing ISI marked 400 watt switch type dimmer including making connection testing etc. as required. |
| 48 | Wiring of 3 pin 6 Amp light point with 1.5 sq.mm Fr PVC insulated unsheathed flexible copper conductor 1.1 KV grade and 1.5 sq.mm FR PVC insulated unsheathed flexiable earth conductor with screws,cup washers,making connections ,testing etc. as per required. |
| 49 | On Board |
| 50 | Supplying and fixing of 5 pin 16 Amp power plug point accessories on SWG metal box of size 175x100x60 mm on surface with connections etc. as required. |
| 51 | Single Phase(Three pin) 32 Amp |
| 52 | Supplying and fixing following size (dia.) if ISI marked medium duty PVC conduit along with accessories in surface ,making good the same as required. |
| 53 | 25 mm |
| 54 | 32 mm |
| 55 | 50 mm |
| 56 | Supplying and drawing FR PVC insulated & unsheathed flexiable conductor ISI marked (IS:694) of 1.1 KV grade and approved making connections etc. as required. |
| 57 | 2 X 2.5 sq.mm + 1 X 1.5 sq.mm (For Light & Power Ckt) |
| 58 | 2 x 4.0 sq.mm + 1 x 2.5 sq.mm (For A.C. Ckt) |
| 59 | Plate Earthing as per IS:3043 with copper Earth plate of size 600mm x 600mm x 3.0mm by embodying 2 to 3 mtr below the ground level with 30 mm dia including all accessories and c.c. finished chamber ,testing of earth resistance as required. |
| 60 | S & Laying following size earth wire /strip in horizontal or vertical run in ground connection etc. as required.8 SWG Copper Wire |
| 61 | P & f strip type fluorscent tube fitting fabricated (Cera) sheet and finished with power coating ) complete with accessories as required.(without tube) |
| 62 | 1 X 36 Watts with CCCB |
| 63 | P & F fluorscent tube rode in existing fixture as required 36/40 Watts. |
| 64 | P & F Celling Fan in existing fixture as required .Usha,Orient,Crompton etc. |