| 1 | [23.1.6.8]COPPER WIRING IN MS CONDUIT (SURFACE/RECESS) 6.8. Wiring main ,sub mains and Circuit wiring in twosingle core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in MS Conduit etc as required. 2 run of Size 4 Sqmm(1/2.24mm) |
| 2 | [23.1.6.9]COPPER WIRING IN MS CONDUIT (SURFACE/RECESS) 6.9. Wiring main ,sub mains and Circuit wiring in twosingle core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in MS Conduit etc as required. 3 run of Size 1.50 Sqmm(1/1.40mm) |
| 3 | [23.2.1.1]COPPER WIRING WITH MODULAR SWITCHES IN MS CONDUITS (SURFACE/RECESS) 1.1. Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etcin 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick MS conduit pipe. Group A |
| 4 | [23.2.4.1]COPPER WIRING WITH MODULAR SWITCHES IN MS CONDUITS (SURFACE/RECESS) 4.1. Wiring in MS conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required Group A |
| 5 | [23.22.5.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole |
| 6 | [23.22.5.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.3. Supply and erection of miniature circuit Breaker240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Double POLE |
| 7 | [23.6.6.1]MS CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.1. Supply and erection of MS conduit pipe 1.6 mm thick , ISI marked surface/recessed in slab/wall/ceiling etc. including cost of MS bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. MS Pipe of 20 mm dia. |
| 8 | [23.6.6.2]MS CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of MS conduit pipe 1.6 mm thick , ISI marked surface/recessed in slab/wall/ceiling etc. including cost of MS bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. MS pipe of 25 mm dia. |
| 9 | [23.8.11.1]FITTING AND ACCESSORIES 11.1. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp 1 way switch |
| 10 | [23.8.11.4]FITTING AND ACCESSORIES 11.4. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp Socket |
| 11 | [23.8.3.1]FITTING AND ACCESSORIES 3.1. Supply and erection of suitable MS/GI Box covered with 5 mm thick Bakelite sheetas below 75 mm x 75 mm x 60 mm deep M.S. box |
| 12 | [24.1.1]EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. |
| 13 | [24.1.12]EARTHING AND LIGHTENING ARRESTOR 12. Supplying and laying 6 S.W.G G.I. wire at 0.50 m below ground level from earth electrode including thimbles, soldering etc. as required. |
| 14 | [24.1.2]EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required. |
| 15 | [24.2.4.2]LT CABLE 4.2. Laying of underground cable in pipe /existing open/closed trench etc as required:- 16 Sq mm to 35 sqmm 2 to 4 Core |
| 16 | [24.2.7.2]LT CABLE 7.2. Supply and erection ofsuitable compression type brass cable glands for underground Cable :- 10 sqmm to 16 sqmm Cable 2 to 4 Core |
| 17 | [24.2.8.4]LT CABLE 8.4. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 16 sqmm |
| 18 | [24.5.2.3]MISCELLANEOUS ITEMS 2.3. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work.DWC/HDPE pipe 63/50 mm outer dia/inner dia |
| 19 | Supply and erection of PVC inslutated (ISI Marked) copper conductor 2 Core cable 1100 V grade in pipe of suitable size excluding cost and erection of pipe but,including connections etc.with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work.Make:- Havell`s/Polycab/Granday16 Sqmm |
| 20 | Design, Supply, Erection, Testing, Installation and Commissioning of Rooftop OffGrid Solar Power PlantComprehensive Maintenance for a period of 5 Years from the date of Commissioning of the system(As per HAREDA) complete in all respect upto the entire satisfaction of Engineer- in- Charge of the work. (Including GST and other taxes). ( Battery Bank Shall consists of series-parallel combination of Batteries (Nominal) and test report from any MNRE/ NABL/BIS/ IEC accredit testing center or from international laboratory. Battery Bank Shall also be provided with Battery Management system (BMS). However, voltage and Ah combination may be changed as per requriement of invertor power conditioning unit (PCU) but capacity in WH shall be equivalent or higher then mentioned against each). Except battery all terms and conditions as per HAREDA. 12 Nos Watch Tower x 1 KW = 12 KW |
| 21 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required |
| 22 | Supply of 10 Watt Bulkhead Light for Outdoor, PVC Water Proof, weatherproof, rust resistant, suitable for operation 230 V, 50 HX AC supply. complete with all accessories and labor to complete the job up to the entire satisfaction of the Engineer-in-charge of the work. Wipro/Crompton/Surya/Philips |
| 23 | Supply and Erection of LED Tube fitting with all accessories as supplied by the manufacturer complete in all respect. Make: Wipro/ Crompton /Surya/Philips. LED Tube Light Fitting 20 Watt |