Military Engineer Services-MES has published Tender For Special Repair To Bldg No T-313 & T-87 Of 626 Sata Bty And Spl Repair To Bldg No T-459 & T-460 Of 255 (I) Abou Under Ge 860 Ews. Submission Date for this Tender is 20-09-2023. Building Work Tenders in Leh Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

39285100
Corrigendum : Tender For Special Repair To Bldg No T-313 & T-87 Of 626 Sata Bty And Spl Repair To Bldg No T-459 & T-460 Of 255 (I) Abou Under Ge 860 Ews
Open Tender
Indian
Jammu And Kashmir
Leh
20-09-2023

Tender Details

Tender For Special Repair To Bldg No T-313 & T-87 Of 626 Sata Bty And Spl Repair To Bldg No T-459 & T-460 Of 255 ( I ) Abou Under Ge 860 Ews; 1 Dismantling Floor Hearth Or Wall Tiling Including Cement Mortar Bedding Complete All As Specified And Directed. 2 Demolition Of Cement Concrete ( Unreinforced ) In Ground Floor And Paving Etc In Exec 15 Cm Thick Below Or Above Gl Complete All As Specified And Directed. 3 M&L 100 Mm Thick Cement Concrete Type B-2, 1:2:4 ( 40Mm Graded Aggregate ) As In Sub-Base To Floors And Similar Work Complete All As Specified And Directed. 4 M&L For Non-Skid Ceramic Tiles 7 To 8 Mm Thick Coloured ( Square / Rectangular ) Area Of Eachtile Exceeding 0.11 Sqm But Not Exceeding 0.18 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Over And Including 15 Mm Thick Screed Bedding In Cement Mortar 1:6 For Laying Floor Finishes Receiving Floor Tiles Complete All As Specified And Directed By Engr-In-Charge. 5 M&L For Coloured Glazed Ceramic Tiles In Vertical Surface Of Size 450X350x7mm Thick Set And Jointed In Net Cement Slurry And Pointed In White Or Color Cement Over And Including 10Mm Thick Backing Coat On Brick / Concretesurface In Cement Mortar 1:4 Complete All As Specified And Directed. 6 Taking Down Cement Plaster On Stone / Brick Wall Including Raking Out Joints Hacking For Key And Scrubbingdown With Water Etc. Complete All As Specified And Direct By Engineer-In-Charge. 7 Rendering 15Mm Thick In Cement Mortar 1:4Finished Even And Smooth Surface Without Using Extra Cement Complete All As Specified And As Directed. 8 M&L For Preparing New Surfaces Including Priming Plastered And Other Surfaces With Alkali Resistant Priming Paint And Applying Two Coat Of Cement Base Paint Complete All As Specified And Directed. 9 M&L Forpreparation Old Surface, Plastered Or Unplastered Old Decorated Surface Of Walls By Brooming Down Or Steel Wire Brushing; Scrapping Down Smoke Soot, Moulds, Moss And Efflorescent Salts And Trading Oil And Greasy Spots And Applying Two Coats Of White / Lime Wash On Walls Including Cornices, Pilasters Etc Complete All As Specified And Directed. 10 M&L Forpreparing Old Surfaces Of Plastered Or Unplastered Surfaces Including Washing Rubbing Down And Scrapping Smoke Soot Moulds, Moss And Greasing Sports With Steel Wire Brush And Applying Two Coat Of Cement Base Paint Complete All As Specified And Directed. 11 Taking Downchowkats Or Frame Exc 1.5 Sqmand N Exc 4 Sqm With Shutters Without Taking Of Shutter From The Frame Complete All As Specified And Directed By Engr-In-Charge. 12 S&F Plain Solid Straight Chowkats Or Frame Rounded Or Chamferedput Together With Glue Pinedat Joints With 2Nd Class Hard Wood Complete All As Specified And Directed. 13 S&F For 30Mm Thick 2Nd Class Hardwood Plain, Framed, Panelled Door Shutters ( Any Number Of Panels ) , With Panels Of Timber Flat On Both Sides ( Feather Edged ) , Veneered Particle Board Medium Density, Wood Particle Board With Commercial Face Veneers, Supplied And Fitted To Chowkats Complete All As Specified And Directed. 14 M&L For Preparation Of Old Painted Of Wood Or Wooden Surfaces And Applying One Coat Of Synthetic Enamel Paint On Surface Of Any Description Over 10Cm Width Or Girth Complete All As Specified And Directed. 15 M&L Preparation Of Untreated New Wooden Surfaces Over 10Cm Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint Over A Coat Of Pink Primer Complete All As Specified And Directed By Engr-In-Charge. 16 Dismantling Wall / Ceiling Board ( Fibre, Pulp Insulation Etc. ) Or Insulation Boards / Slabs / Blankets, Any Thickness Including Fillets Complete All As Specified And Directed. 17 M&L For Veneered Decorative Plywood 4Mm Thick ( 3 Nos Of Ply ) Grade 1 ( Withbwr Resin ) With Decorative Face Veneers One Face Fixed With Nails To Timber Frame Work Complete As In Ceiling Paneling Complete All As Specified And Directed. 18 M&L For Veneered Decorative Plywood 4Mm Thick ( 3 Nos Of Ply ) Grade 1 ( Withbwr Resin ) With Decorative Face Veneers One Face Fixed With Nails To Timber Frame Work Complete As In Wall Paneling Complete All As Specified And Directed. 19 Dismantling Of Timber Scantling Plain Fillet Under 40 Sq Cm In Section In Framed Work Complete All As Specified And As Directed. 20 M&Lsecond Class Soft Wood Timber Scantling Plain Fillets, Square, Rectangular Or Triangular In Section Clear Swan, Sectional Area Exc 13 Sqcm & Not Exc 25 Sqcm, Secured With Nails Or Brads Complete All As Specified And Directed. 21 M&Lfirst Class Soft Wood Sectional Area Not Exceeding 6 Sqcmmoulding As In Cornices, Picture Rails And Thelike , Secured With Nails Or Brads Complete All As Specified And Directed. 22 S&F For 150Mm Extruded Aluminium Handle Complete All As Specified And As Directed. 23 S&F Mild Steelbutt Hinges Medium Weight Cold Rolled Mild Steel Size Of Hinges 100 Mm Complete All As Specified And As Directed. 24 S&F Aluminium Alloy Barrel Tower Bolt Of Extruded Type 150 Mm Long Complete All As Specified And As Directed. 25 Hacking Out Oldbroken Glass Ofany Thickness Size Or Quality From Steel Frames Complete All As Specified And As Directed. 26 S&F For 4Mm Thick Sheet Glass Ordinary Quality And Glazing Withaluminium Snap Beading On Aluminium Frame For Door / Window And Ventilatorin Square N Exc 0.5 Sqm Each Complete All As Specified And Directed. 27 Dismantling Plain Or Corrugated Steel Sheeting, Any Gauge, Thickness, Including Nainital Or Similar Pattern Roof Covering Or Wall Etc Complete All As Specified And As Directed. 28 0.50 Mm Thick Galvanised, Corrugated Mild Steel Sheeting With Two Corrugationsside Lap, Fixed With L-Type Or J-Type Or Cranked Hook Bolts, In Roofs, Walls Etc. With Grade Of Zinc Coating 275 As Specified And Directed. 29 0.50Mm Thickplain, Galvanised, Mild Steel Sheeting, In Ridges, Hips, Valley Gutters, Drip And Straight Flashings ( Length And Girth As Fixed ) , With Grade Of Zinc Coating 275 As Specified And Directed. 30 M&L Preparation Of New Or Previously Untreated Steel And Iron Surfaces Of Any Description Over 10 Cm Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer Complete All As Specified 31 M&L Two Coat Of Synthatic Enamel Paint Over A Old Steel Surfaceof Any Description, Over 10Cm In Width Or Girth, Not Otherwise Describe Complete All As Specified And Directed. 32 Taking Up And Down Gi Tubing And Connection Including Cleaning For Re-Fixing Or Removing To Store 15Mm Bore Of Pipe Complete All As Specified And As Directed. 33 Taking Up And Down Gi Tubing And Connection Including Cleaning For Re-Fixing Or Removing To Store 20Mm Bore Of Pipe Complete All As Specified And As Directed. 34 S&F20mm 3-Layer Pp-R Polypropylene Random Copolymer ) Concealed Pipes Sdr 7.4 ( Pn16 ) Uv Stabilized And Antimicrobial Fusion Welded Having Thermal Stability For Hot & Cold Water Supply Including All Pp-R Plain & Brass Threaded Polypropylene Random Fittings Fixed Complete To Walls, Ceilings Or In Floors Etc Complete All As Specified And Directed. 35 S&F16mm 3-Layer Pp-R Polypropylene Random Copolymer ) Concealed Pipes Sdr 7.4 ( Pn16 ) Uv Stabilized And Antimicrobial Fusion Welded Having Thermal Stability For Hot & Cold Water Supply Including All Pp-R Plain & Brass Threaded Polypropylene Random Fittings Fixed Complete To Walls, Ceilings Or In Floors Etc Complete All As Specified And Directed By Engr-In-Charge. 36 S&F In Repair Pvc 10 Ltrs Valve Less, Syphonic Action Type, Flushing Cistern, Low Level, White, With Inlet, Ball Valve, Float And Handle Including Brackets Complete With 32 Mm Dia Flush Pipe Connecting To Squatt Pattern Etc. Isi Approved Complete All As Specified And Directed. 37 S&F In Repairs Vitreous China Water Closet ( Squatt Pan ) Orrisa Pattern 580X440 Mm Size Pan White Withfront Or Back Inlet With Integral Foot Rests Including Provn Of Lime Concrete Bedding Including Connections To Flushing Cistern / Pipe Complete All As Specified And Directed Including 100Mm Ci P Trapcomplete All As Specified And Directed. 38 S&Fvitreous China ( Ewc ) Pedestal Pan And Trap , Including Connection To Drain ( Or Outgoing Pipe ) And To Flushing Pipe Antisyphonage Pipe, With Seat Cover Etc Complete Including Concrete And Making Good To Floor Complete All As Specified And Direct By Engineer-In-Charge. 39 S&F In Repairs Vitreous China Wash Hand Basin, White, Flat Back Size 550 X 400Mm Including Brackets Waste Brass Chromium Plated With Long Screwed Shanks And Fly Nuts 32Mm Size Bore Of Pipe Complete All As Specified And Directed. 40 S&F Vitreous China Urinals In Repairs, Bowl Type ( Back Or Corner Wall Type ) , Complete Including Providing And Fixing Plugs, Bedding Urinal Against Wall In Cement Mortar 1:2, Securing Urinal To Plugs With And Including 60Mm Long Brass Screws, Pointing Around Urinal Back In Cement; Fixing Automatic Flushing Cistern With Brackets, Flush Pipe, Grating And Union For Discharge Pipe. ( Exclusive Of Fixing Supply Pipe To Flushing Cistern, Trap And Waste Pipe ) Complete All As Specified And Directed. 41 S&F In Repair Stop Valves 15Mm Bore Chromium Plated, Cast Copper Alloy Screwed Down High Pressure With Crutch Or Butter Fly Handle Screwed Both Ends For Iron Pipe Or For Union Complete All As Specified And Directed. 42 S&F In Repair Bib Taps 15Mm Dia Cast Copper Alloy With Crutch Or Butter Fly Handle Fancy Typescrewed Down For Iron Pipe Or For Brass Ferrule Complete All As Specified And Directed. 43 S&F In Repair 15Mm Bore Pillar Taps Cp Brass Chromium Plated Fancy Type Screwed Down High Pressure With Chromium Plated Screwed Shanks And Fly Nuts Complete Screwed For Iron Pipe In Repairs Complete All As Specified And Directed. 44 S&F In Repairs Pvc Connection 15 Mm Bore 450Mm Long With Screwed Socket Of Brass On Both Ends And Rubber Washer Complete All As Specified And As Directed. 45 S&F In Repairs Ldpe ( Low Density Polyethylene Pipes ) Of Pressure Rating 6Kg / Sqcm 32Mm Diawaste Pipe As In Wash Basin Complete All As Specifed And As Directed. 46 S&F In Repair Of Soap Dish, Any Type, Fixed To Plugs With Chromium Plated Brass Screws Complete All As Specified And Directed. 47 S&F In Repair Brass Chromium Plated Tubular Towel Rail 20 Mm Dia D Type 60 Cm Long Complete All As Specified And Directed. 48 S&F In Repair Rotational Moulded Polythylene Water Storage Tanks 1000 Ltrs, Triple Layered ( Cylindrical Vertical With Closed Top ) Hoisted And Fixed In Position Complete All As Specified And Directed. 49 S&F 20Mm Bore Gun Metal, Globe Or Gate Valves, With Iron Wheel Head, Screwed Both Ends For Iron Pipe And Fixed Complete All As Specified And Directed. 50 S&F In Repairs600mmx450mm Bevelled Edge Mirror 5 Mm Thickof Selected Quality Glass, Mounted On 6Mm Thick Ac Building Board Or Comercial Plywood And Fixed To Wooden Plugs With Chromium Plated Brass Screws And Cup Washer And Taking Down Old Mirrorcomplete All As Specified And Directed. 51 M&L For Providing Precast Cement Concrete Type C-1 1:3:6 ( 20Mm Graded Crushed Stone Aggregate ) In Landings, Cover Slabs ( For Manholes Etc. ) Chullah Hoods , Chajjas, Water Troughs , Mangers, Shelves And Similar Articles With Plain Faces Complete All As Specified And Directed. 52 Demolition And Breaking Up Drain Pipes ( Salt Glazed Ware, Pvc Or Re-Inforced Concrete ) Set In Cement Mortar Internal Dia Of Pipe 150 Mm Complete All As Specified And As Directed 53 M&L Plain Cement Concrete 1:3:6 Type C-2 ( Using 40 Mm Graded Crushed Stone Aggregate ) As In 150Mm Bore Of Pipe In Concrete Bed To Drain Pipes Including Packing Under And Haunching Against The Sides Of Pips After They Are Laid And Tested Complete All As Specified And Directed. 54 S&F 150 Mm Dia Bore Pvc ( Swr ) Pipes Single Socketedin Any Length With Rubber Ring Joints, Laid In Trenches Or In Floors Complete All As Specified And As Directed. 55 S&F 150Mm Dia Bore Pvc ( Swr ) Bends Complete All As Specified And Directed. 56 S&F 150Mm Dia Bore Pvc ( Swr ) Junction Single, ( Single T ) Equal Or Unequal Complete All As Specified And Directed. 57 Dismantling Of Cast Iron Swrpipes From Any Position Of 100Mm Dia Complete All As Directed. 58 S&F 110Mm Dia Pvc ( Swr ) Pipes Single Socketedin Any Length With Rubber Ring Joints Fixed To Wall Complete All As Specified And As Directed. 59 S&F Pvc ( Swr ) Vent Cowl 110Mm Dia All As Specified And Directed. 60 S&F 110 Mm Dia Pvc ( Swr ) Bend Any Radius Complete All As Specified And Directed. 61 S&F 110Mm Dia Pvc ( Swr ) Branch Pieces Double ( Double Y ) Equal Or Unequal All As Specified And Directed. 62 S&F 110Mm Dia Pvc ( Swr ) Junction Single ( Single T ) Equal Or Unequalall As Specified And Directed. 63 S&F 75Mm Dia Pvc ( Swr ) Floor Trap Plain With Grating Including Jointing To Waste Pipe Fixed In Solvent Cement Or Cement Concrete 1:2:4 Type B1all As In Repairsspecified And Directed. 64 M&L For75 Mm Thick Plain Cement Concrete ( 1:3:6 ) Type C-2 ( Using 40 Mm Graded Crushed Stone Aggregate ) As In Plinth Protection / Pathand Fininshed Even And Fair Without Using Extra Cement Complete All As Specified And Directed. 65 S&F Chequered Cement Concrete Tiles 30Cm X 30Cm X 25Mm Thick, Set, Jointed And Pointed In Neat Cement Slurry In Floors Including 15 Mm Thick Screed Bedding In Cm 1:6. For Laying Floor Finishes Receiving Floor Tiles Andgeay Pigment Cement And Pigments In Floorfinishes Complete All As Specified And Directed. 66 M & L Pre-Painted Galvalume Aluminum Zinc Coating Gi Based Corrugated Steel Sheet 0.50Mm Thick Of An Colour Having Tensile Strength Of 550 Mpa As In Roof Covering / Cladding To Wall, Fixed With Self Tapping Screws As Specified And Directed. 67 S&F 2Mm Fibre Glass Reinforced Translucent Corrugated Sheeting With Two Corrugations Side Lap Fixed With Coach Screw And Washer In Roof, Wall Etc Complete All As Specified And Directed. 68 Taking Down Shutters Of Any Descriptionexc 1 Sqmand N Exc 2 Sqm Complete All As Specified And Directed. 69 S&F For 30Mm Thick Flush Shutters, Solid Core Construction, With Block Board Core And Plywood Face Panels, Commercial Type On Both Sides Complete All As Specified And Directed. 70 S&F Galvanised Mildsteelwire Cloth, 0.63Mm Nominal Dia Of Wire And Average Width Of Aperture 1.40Mm And Fixed With Tinned Tacks, Or Galvanised Wire Staples Complete All As Specified And As Directed. 71 S&F Grating Doom 100 Mm Dia With Waste Hole Of Ptmt ( Minimum Weight 25Gms ) Complete All As Specified And Directed. 72 S&F In Repairs Door Closer Hydraulically Cast Iron Regulated, Designation No.3, Universal Type, Suitable For Door Shutters Of 851 To 1000 Mm In Width And Of Weight Between 61 To 80 Kg And Fixedcomplete All As Specified And As Directed. 73 S&F 300 Mm Long Aluminium Alloy, Anodized, Sliding Door Bolt With Hasp, Staple ( Bolt Type ) And Fixing Clips Of Sheet, Cast Or Extruded Sections And Fixing Bolts And Sliding Bolts Of Extruded Sections Or Cast Aluminium Alloy Complete All As Specified And Directed. 74 S&F Anodised Aluminium Frame For Partition With One Or More Rebates Including Joining Cleat For Fixing Including Necessary Joining Cleats, Glazing Clips, Ruber Neoprene Packing, Handles 2 Nos In Each Door, Hinges, Anodised Aluminum Snap Beading Screws Etc. Complete All As Specified And Directed By Engr-In-Charge. 75 S&F Figured Glass 5.0Mm Thick, Pin Head Type And Glazing With Oil Putty In Squares N Exc 0.5 Sq. M In Each Pane Complete All As Specified And Directed. 76 S&F Sheet Glass 5.5Mm Thick, Ordinary Quality And Glazing With Rubber And Complete Accessoryin Squareexc 0.5 Sq. M In Each Complete All As Specified And Directed. 77 S&F Anodised Aluminium Door Shutters, Aluminium Section Weighing 0.55 Kg / M Including Necessary Joining Cleats, Glazing Clips, Ruber Neoprene Packing, Handles 2 Nos In Each Door, Hinges, Anodised Aluminum Snap Beading Screws Etc. Complete All As Specified And Directed. 78 S&F Anodised Aluminium Window And Ventilator Shutters, Fixed Type Without Sash Bar, Aluminium Section Weighing 0.55 Kg / M Including Necessary Joining Cleats, Glazing Clips, Rubber Packing, Anodised Aluminium Snap Beading, Screws Etc. Complete All As Specified And Directed By Engr-In-Charge. 79 S&F In Repairs Curtain Rails, Mild Steel, Chromiumplated With Fixing Brackets, Stops, Rollers Etccomplete All As Specified And Directed. 80 Demolition Of Pcc Block / Stone Masonry Built In Cement Mortarincluding Allquoins, Arches, Pillars, Etc, But Including Ashlar Facings, Dressed Stonework And Precast Concrete Articlesin Any Position Complete All As Specified And Directed. 81 M&L Precast Cement Concreteblock Masonry Type C-1 1:3:6 ( 20Mm Graded Crushed Stone Aggregate ) With Solid Blocks, Exc. 10Cm In Width And, Setting Incement Mortar 1:6 Complete All As Specified And As Directed. 82 M&L For Preparing New Surfaces Of Walls And Appplying Two Coat Of White Wash Complete All As Specified And As Directed. 83 S&F Grid False Ceiling Gi System Powder Coted Prelude, ( Main Runner Section 32X24x0.30X36mm, Corss Tee 25X24x0.30X1200mm, Wall Angle 24X24x0.40X3000mm And Including Providing Fixing Pvc Pre-Laminated In Front Side And Aluminium Foil Backed Gypsum Tile Board Of Size 595 X 595 X 8-9Mm Fixed In Ceiling Frame Work With Necesssary Fastening Gi Wire And Cleats Complete All As Specified And Directed. 84 Demolition Of Old Unserviceable Soakage Well Of Any Size And Make Good The Surface By Filling Or Removing Debris / Earth, Complete All As Specified And Directed By Engr-In-Charge. 85 Excavation Over Areas N.Exc 1.5M Deep And And Getting Out In Hard / Dense Soil Complete All As Specified And As Directed. 86 Excavation Over Areas Exc 1.5M Deep And N.Exc 3.00 M Deep And Getting Out In Hard / Dense Soil Complete All As Specified And As Directed. 87 Excavation Over Areas Exc 3.0 Deep And N.Exc 4.5 M Deep And Getting Out In Hard / Dense Soil Complete All As Specified And As Directed. 88 M & L For Pcc 1:3:6 Type C-2 ( Nominal Mix ) Using 40 Mm Graded Crushed Stone Aggregateas In Foundation Filling Mass Concrete And Similar Work Complete All As Specified And As Directed. 89 M & L For Walling Of Random Rubble Uncoursed, Well Bonded, Bedded And Solidly Hearted, Built In Cement Mortar 1:6Complete All As Specified And Directed 90 M & L For Walling Of Random Rubble Stone Masonary, Uncoursed, Well Bonded, Bedded And Solidly Hearted, Laid Drycomplete All As Specified And Directed 91 Use And Waste Of Rough Finished Formwork To Soffits Of Suspended Slabs Such As Roof Slabs, Floor Slabs, Landings And Similar Work; Not Exceeding 200Mm Thick ( Horizontal Or Sloping ) All As Specified And Directed. 92 Use And Waste Of Formwork To Edges Of Concrete Flats, Treads, Breaks In Floors, Window Cills, Concrete Railings, Openings In Concrete Walls, Floor And Roof N.Exc 20 Cm Wide And Sides Of Rcc / Pcc Bands In Walls, Horizontal Or Sloping And Similar Work Exc 10 Cm But N.Exc 20 Cm Wide Complete All As Specified And As Directed. 93 Tmt Steel Bars 10Mm Dia And Over ( 12Mm ) , Cut To Length, Bent To Shape Required, Including Cranking, Bending Spirally For Hooping Forcolumns, Hooking Ends And Binding With And Including Mild Steel Wire ( Annealed ) Not Less Than 0.9Mm Dia Or Securing With Clips 94 M & L For Providing Rcc Type B-1 1:2:4 Using 20 Mm Graded Crushed Stone Aggregatein Slabs Supported On Walls, Beams And Columns In Floors, Roofs, Landings, Balconies, Canopies, Deck Slabs And In Shelves And The Like All As Specified And Directed. 95 M & Lfor Precast Cement Concrete 1:2:4 Type B-1 Using 20Mm Graded Crushed Stone Aggregate As In Cover Slab For Manhole Set In Cement Mortar 1:4 Including Necessary Form Work Complete All As Specified And Directed 96 Excavation In Trenches N.Exc 1.5 M Wide And N.Exc 1.5 M Depth And N.Exc 10 Sqm On Plan And Getting Out In Hard / Dense Soil Complete All As Specified And Directed. 97 Returning, Filling In Including Spreading, Levelling, Watering And Well Ramming In Layers Not Exc 25 Cm Complete All As Specified And As Directed. 98 Removing Excavated Material N Exc. 50M And Depositing Where Directed At A Level N Exc. 1.5 M Above The Starting Point Complete All As Specified And As Directed. 99 15 Mm Thick Renderingin Cement Mortar 1:3 ( Using Water Proofing Compound ) On Pcc Block Walling Or Concrete Surfaces And Finished Even And Fair As Specified And Directed. 100 M&L For Plain Cement Concrete 1:3:6 Type C-1 Using 20Mm Graded Crushed Stone Aggregate As In Coping, Benching Bed Plates And The Line Including Necessaryform Work And Finishing All Exposed Surface Of Concrete As Per Clause 4.11.16.2 ( A ) Of Ssr Part-I ( 2009 ) Complete All As Specified And Directed. 101 S&F 110Mm Dia Bore Pvc ( Swr ) Pipes Single Socketed In Any Length With Rubber Ring Joints Fixed To Floors Complete All As Specified And As Directed. 102 M&L Cement Concrete Bed 1:4:8 Type D-2 ( Using 40 Mm Graded Crushed Stone Aggregate ) To Drain Pipes Including Packing Under And Haunching Against The Sides Of Pipes After They Are Laid And Tested Bore Of Pipe In 110 Mm Complete All As Specified And As Directed. 103 Supply Only Integral Water Proofing Compound Complete All As Specified. 104 Taking Down Carefully Alluminium / Copper Point Wiring Complete For Light, Fan, Socket Or Power Point Etc With Fittings Fixtures Such As Ceiling Rose, Holders, Electric Fittings, Switchs, Sockets, Aluminium Conductor Cable With And Incl Wooden Batten Or Fr Pvc Conduit And Its Accessories Such As Wooden Gutties, Rawl Plugs, Gi Screws, Aluminium Clips, Nails Etc Complete And Removing The Material From Site And Making Good The Disturbed Surface Of Wall / Floor / Ceiling Etc As Original I.E. Brick Work, Plastering, White Washing, Obd Etc As Required, Complete All As Specified And Directed. 105 M&L Point Wiring Complete With Single Core Frls Pvc Insulated, Unsheathed, Multi Stranded Copper Conductor Cables 1.5 Sqmm 1100 Volts Grade, With And Incl 1.5 Sqmm Frls Pvc Insulated, Unsheathed, Multi Stranded Copper Conductor Cables As Continuous Earth Wire Connected To Metallic Bodies Of Luminaries / Fans Etc At One End And To Common Earth Dolly At Other End, Complete Wiring Drawn Through & Pvc Casingand Cappingof 25 Mm And Above ( As Per Conductor Run ) Medium Grade, Isi Marked, Incl All Accessories & Fittings / Junction Boxes / Inspection Covers Etc, With And Including Surface Pvc Boxes Of Suitable Size Fixes With Wall Surface, Gang Box For Top Cover Suitable For Fixing Of Piano Type Switches / Sockets Etc, Complete All As Specified And Directed For The Following :- 106 One Light / Bell / Buzzer / Exhaust Fan Point Controlled By One No, 1-Way, 5 Amps Switch. 107 One Socket Outlet 3 Pin, 5 Amps On Independent Board, Controlled By One No 5 Amp Switch. 108 One Socket Outlet 3 Pin 5 Amps On The Same Board Controlled By One No. 5 Amp Switch. 109 All As Per Srl Item No. 105.00 Here-In-Before But With 2.5 Sq Mmfrls Copper Wire With 1.5 Sqmm Frls Copper Earth Wire For Indpendent 15 Amp Point. 110 S&F, In Replacement, Of Switch Piano Type, Single Pole, One Way, 5 Amps, 230 Volts, Complete All As Specified And Directed. 111 S&F, In Replacement, Of Switch Socket Combination, Two-In-One, 5 Pin, 5 Amp, Universal Type, 230 Volts, Complete All As Specified And Directed. 112 S&F, In Replacement, Of Switch Piano Type, Single Pole, One Way, 15 Amps, 230 Volts, Complete All As Specified And Directed.Make : Anchor / Ssk / Leader 113 S&F, In Replacement, Of Switch Socket Combination, 6 Pin, 5 / 15Amp, Multipurpose Shutter Type, 230 Volts, Complete All As Specified And Directed. 114 S&F, In Replacement, Of Ceiling Rose, Two To Three Terminals, Bakelite Body, 230 Volts, Complete All As Specified And Directed. 115 Supply And Fixing Led Lights Fitting 1X 20W, 220V, Ac Decorative Box Type With Driver, Holder Including Led Tube Light Connecting Up With Three Core Flexible Copper Conductor Cable Of Suitable Size From Ceiling Rose Complete. 116 S&F In Replacement Of Led Light Fitting Mirror Type With High Out Put Diffuser 2 Feet, 10 Watt 220 V Ac Decorative Type With Driver Holder And Led Lamp Including Connecting Up With Three Core Flexible Copper Conductor Cable Of Suitable Size Complete 117 S & F Led Light Fitting 1X9w / 1X10w Bulkhead Luminaires Including Led Light Driver Holder Connecting Up With Three Core Flexible Copper Conductor Cable Of Suitable Size Complete All As Specified And As Directed. 118 S&F In Replacement Of Angular Lamp Holder, Pvc / Polycaronate Type With Back Plate Suitable For 9 Watt Led Bulb Forbatten Fittings Complete All As Specified And Directed. 119 S&F In Replacement Of 9W Led Bulb Complete All As Specified. 120 S&F In Replacement Of Db, Double Door, Made Out Of Crca Mild Steel Sheet Surface With Insulated Material Like Polyester Or With Epoxy Powder Coating And Ip 43 & Ik 09 Protection, Spn 4 Way, 240 Volts With Bus Bar Rating 200 Amps, Dust And Vermin Proof, Suitable For Incorporation Of Mcb’S And Isolators Etc And Making All Necessary Connections, Duly Flush Of Wall Surface, Complete All As Specified And Directed. 121 S&F In Replacement Led Street Light Fitting 35 Watt 230 V Ac Outdoor Type With High Pressure Die Cast Aluminum Hosing And Heat Resistant Complete With Driver, Lamp Bracket With Impact And Corrosion Resistant Including Thermal Anagement In Multiple Optics Complete With Ip 65 / 66 Protection Complete All As Directed By Engr-In-Charge At Site Including Necessary Fixing Arrangementlike Bracket, Clamps And Nuts And Bolts Complete All As Specified And As Directed. 122 S&F In Replacement Exhaust Fans Made Of Sturdy Engineering Plastic Ac Single Phase 230 / 240 V Of Size 250 Mm Sweep With Louvre Complete In Cluding Making Hole In The Wall And Making Good The Disturbed Surfaces Complete All As Directed. 123 S&F In Replacement Of Db, Double Door, Made Out Of Crca Mild Steel Sheet Surface With Insulated Material Like Polyester Or With Epoxy Powder Coating And Ip 43 & Ik 09 Protection, Spn 8 Way, 240 Volts With Bus Bar Rating 200 Amps, Dust And Vermin Proof, Suitable For Incorporation Of Mcb’S And Isolators Etc And Making All Necessary Connections, Duly Flush Of Wall Surface, Complete All As Specified And Directed. 124 S&F In Replacement Of Mcb, C Curve Type, 10 Ka, 40 To 63 Amp, Spn With Over Load And Short Circuit Protection, Complete All As Directed. 125 S&F In Replacement Of Mcb, C Curve Type, 10 Ka, 6 To 40 Amp, Single Pole With Over Load And Short Circuit Protection, Complete All As Directed. 126 M&L For Sub Main Wiring With 2 Run Of 6 Sqmm Frls, Pvc Insulated, Unsheathed And Stranded Copper Conductor Cable With And Incl 6 Sqmm ( Nominal Area ) Frls, Pvc Insulated, Unsheathed And Stranded Copper Conductor Cable As Earth Wire Connected With Thimble From Main Db To Sub Main Db, Drawn In To Separate, Isi Marked, Non Metallic Pvc Conduit 20 Mm Dia Size Incl All Conduit Accessories & Fittings / Junction Boxes / Inspection Covers Etc, With And Incl Cutting Chasing And Making Good Of Disturbed Surface Of Wall / Floor / Ceiling Etc As Original By Brick Work, Plastering, White Washing, Obd Etc As Required, Complete All As Directed.Note : 1. The Cost Of Conduit & Accessories Is Deemed To Be Included In Quoted Rates.2. The Two Run Of 6.00 Sqmm Wire And One Run Of 6.00 Sqmm Wire Will Be Measured As One Unit. 127 Supply And Laying Xlpe Insulated, Armoured, Heavy Duty Electric Cable, With Stranded Aluminum Conductor 1100 V Grade Nominal Cross Sectional Area 10 Sqmm, 2 Core Laid In Trenches, Ducts, Drawn Through Pipes Across The Road / Path / Along Poles / Wall / Floors / Equipment Etc Including Jointing And Testing Complete All As Specified And Directed. 128 Material And Labour For Un-Reinforced Pre-Cast Concrete Cable Covers, Class Lv Type-1, Flat Size 250Mm X 150Mm X 40Mm Thick Complete All As Specified. 129 Material And Labour For Sand Cushioning To Under Ground Electric Cable All As Per Clause No 19.75 Of Mes Ssr Part-I ( 2009 ) Complete All As Specified And As Directed. 130 M&L For Earthing With Galvanized Steel Earth Plate Electrode Of Size 600 X 600 X 6 Mm Buried Directly In Ground Earth Pit Not Less Than 2.25 Mtr Below Of Normal Ground Level With Top Edge Of Earth Plate Should Not Less Than 1.5 Mtr Below Normal Ground Level And Connected To Galvanized Iron Earth Lead Wire Of Size 4 Mm Dia By Means Of Bolts, Nuts, Washers Of Galvanized Iron Or Steel All As Shown In Electrical Plate No.3 Of Mes Ssr Part I Connecting To Earthing Test Point On Completion With And Including 15 Mm Bore Gi Light Grade Protection Pipe ( 7.5 Mtr Long ) For Earth Lead Gi Lead Wire 4Mm Dia ( 7.5 Mtr Long ) , Pcc Pit With Cover In Pcc 1:2:4 Type B-1 Reinforced With 8 Mm Dia Tor Bars @ 80Mm C / C, 20Mm Dia Medium Grade Watering Pipe With Funnel, Wire Mesh, Common Salt, Charcoal, Necessary Excavation And Earth Work, Complete All As Specified And Directed.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 13-Sep-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 20-09-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 83300.0 /-
Tender Value
INR 41.60 Lakhs /-

BOQ Items

Name of Work : SPL REPAIR TO BLDG NO T-313 & T-87 OF 626 SATA BTY AND SPL REPAIR TO BLDG NO T-459 & T-460 OF 255 (I) ABOU UNDER GE 860 EWS
Sl. No. Item Description
1Dismantling floor hearth or wall tiling including cement mortar bedding complete all as specified and directed.
2Demolition of cement concrete (unreinforced)in ground floor and paving etc in exec 15 cm thick below or above GL complete all as specified and directed.
3M&L 100 mm thick cement concrete type B-2, 1:2:4 (40mm graded aggregate) as in sub-base to floors and similar work complete all as specified and directed.
4M&L for Non-skid Ceramic tiles 7 to 8 mm thick coloured (square/ rectangular) area of eachtile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bedding in cement mortar 1:6 for laying floor finishes receiving floor tiles complete all as specified and directed by Engr-in-Charge.
5M&L for Coloured glazed ceramic tiles in vertical surface of size 450x350x7mm thick set and jointed in net cement slurry and pointed in white or color cement over and including 10mm thick backing coat on brick/concretesurface in cement mortar 1:4 complete all as specified and directed.
6Taking down cement plaster on stone/brick wall including raking out joints hacking for key and scrubbingdown with water etc. complete all as specified and direct by Engineer-in-Charge.
7Rendering 15mm thick in cement mortar 1:4finished even and smooth surface without using extra cement complete all as specified and as directed.
8M&L for preparing new surfaces including priming plastered and other surfaces with alkali resistant priming paint and applying two coat of cement base paint complete all as specified and directed.
9M&L forpreparation old surface, plastered or unplastered old decorated surface of walls by brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying two coats of white/lime wash on walls including cornices, pilasters etc complete all as specified and directed.
10M&L forpreparing old surfaces of plastered or unplastered surfaces including washing rubbing down and scrapping smoke soot moulds, moss and greasing sports with steel wire brush and applying two coat of cement base paint complete all as specified and directed.
11Taking downchowkats or frame exc 1.5 Sqmand n exc 4 sqm with shutters without taking of shutter from the frame complete all as specified and directed by Engr-in-Charge.
12S&F Plain solid straight chowkats or frame rounded or chamferedput together with glue pinedat joints with 2nd class hard wood complete all as specified and directed.
13S&F for 30mm thick 2nd class hardwood Plain, framed, panelled door shutters(any number of panels), with panels of timber flat on both sides(feather edged), veneered particle board medium density, wood particle board with commercial face veneers, supplied and fitted to chowkats complete all as specified and directed.
14M&L for preparation of old painted of wood or wooden surfaces and applying one coat of synthetic enamel paint on surface of any description over 10cm width or girth complete all as specified and directed.
15M&L preparation of untreated new wooden surfaces over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engr-in-Charge.
16Dismantling wall/ceiling board (fibre,pulp insulation etc.) or insulation boards/slabs/blankets, any thickness including fillets complete all as specified and directed.
17M&L for Veneered decorative plywood 4mm thick (3 Nos of ply) grade 1 (withBWR resin) with decorative face veneers one face fixed with nails to timber frame work complete as in ceiling paneling complete all as specified and directed.
18M&L for Veneered decorative plywood 4mm thick (3 Nos of ply) grade 1 (withBWR resin) with decorative face veneers one face fixed with nails to timber frame work complete as in wall paneling complete all as specified and directed.
19Dismantling of timber scantling plain fillet under 40 Sq cm in section in framed work complete all as specified and as directed.
20M&Lsecond class soft wood timber scantling plain fillets, square, rectangular or triangular in section clear swan, sectional area exc 13 sqcm & not exc 25 sqcm, secured with nails or brads complete all as specified and directed.
21M&LFirst class soft wood sectional area not exceeding 6 sqcmMoulding as in cornices, picture rails and thelike , secured with nails or brads complete all as specified and directed.
22S&F for 150mm extruded aluminium handle complete all as specified and as directed.
23S&F Mild steelbutt hinges medium weight cold rolled mild steel size of hinges 100 mm complete all as specified and as directed.
24S&F Aluminium alloy barrel tower bolt of extruded type 150 mm long complete all as specified and as directed.
25Hacking out oldbroken glass ofany thickness size or quality from steel frames complete all as specified and as directed.
26S&F for 4mm thick sheet glass ordinary quality and glazing withaluminium snap beading on aluminium frame for door/window and ventilatorin square n exc 0.5 sqm each complete all as specified and directed.
27Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering or wall etc complete all as specified and as directed.
280.50 mm thick Galvanised, corrugated mild steel sheeting with two corrugationsside lap, fixed with L-type or J-type or cranked hook bolts, in roofs, walls etc. with grade of zinc coating 275 as specified and directed.
290.50mm thickPlain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed), with grade of zinc coating 275 as specified and directed.
30M&L preparation of new or previously untreated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified
31M&L two coat of synthatic enamel paint over a old steel surfaceof any description, over 10cm in width or girth,not otherwise describe complete all as specified and directed.
32Taking up and down GI tubing and connection including cleaning for re-fixing or removing to store 15mm bore of pipe complete all as specified and as directed.
33Taking up and down GI tubing and connection including cleaning for re-fixing or removing to store 20mm bore of pipe complete all as specified and as directed.
34S&F20mm 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc complete all as specified and directed.
35S&F16mm 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc complete all as specified and directed by Engr-in-Charge.
36S&F in repair PVC 10 Ltrs valve less, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete with 32 mm dia flush pipe connecting to squatt pattern etc. ISI approved complete all as specified and directed.
37S&F in repairs vitreous china water closet (Squatt pan) orrisa pattern 580x440 mm size pan white withfront or back inlet with integral "foot rests including provn of lime concrete bedding including connections to "flushing cistern/pipe complete all as specified and directed including 100mm CI "P" trapcomplete all as specified and directed.
38S&FVitreous china (EWC) pedestal pan and trap , including connection to drain( or outgoing pipe ) and to flushing pipe antisyphonage pipe, with seat cover etc complete including concrete and making good to floor complete all as specified and direct by Engineer-in-Charge.
39S&F in repairs vitreous china Wash hand basin, white, flat back size 550 x 400mm including brackets waste brass chromium plated with long screwed shanks and fly nuts 32mm size bore of pipe complete all as specified and directed.
40S&F Vitreous China urinals in repairs, bowl type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and directed.
41S&F in repair stop valves 15mm bore chromium plated, cast copper alloy screwed down high pressure with crutch or butter fly handle screwed both ends for iron pipe or for union complete all as specified and directed.
42S&F in repair bib taps 15mm dia cast copper alloy with crutch or butter fly handle fancy typescrewed down for iron pipe or for brass ferrule complete all as specified and directed.
43S&F in repair 15mm bore pillar taps CP brass chromium plated fancy type screwed down high pressure with chromium plated screwed shanks and fly nuts complete screwed for iron pipe in repairs complete all as specified and directed.
44S&F in repairs PVC connection 15 mm bore 450mm long with screwed socket of brass on both ends and rubber washer complete all as specified and as directed.
45S&F in repairs LDPE (Low density polyethylene pipes) of pressure rating 6Kg/sqcm 32mm diawaste pipe as in wash basin complete all as specifed and as directed.
46S&F in repair of soap dish, any type, fixed to plugs with chromium plated brass screws complete all as specified and directed.
47S&F in repair brass chromium plated Tubular Towel rail 20 mm dia D type 60 cm long complete all as specified and directed.
48S&F in repair rotational moulded polythylene water storage tanks 1000 ltrs, triple layered (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed.
49S&F 20mm bore Gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
50S&F in repairs600mmX450mm bevelled edge mirror 5 mm thickof selected quality glass, mounted on 6mm thick AC building board or comercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washer and taking down old mirrorcomplete all as specified and directed.
51M&L for Providing precast cement concrete type C-1 1:3:6 (20mm graded crushed stone aggregate) in landings, cover slabs (for manholes etc.) chullah hoods , chajjas,water troughs ,mangers, shelves and similar articles with plain faces complete all as specified and directed.
52Demolition and breaking up drain pipes (salt glazed ware, PVC or re-inforced concrete) set in cement mortar internal dia of pipe 150 mm complete all as specified and as directed
53M&L Plain cement concrete 1:3:6 type C-2 (Using 40 mm graded crushed stone aggregate) as in 150mm bore of pipe in concrete bed to drain pipes including packing under and haunching against the sides of pips after they are laid and tested complete all as specified and directed.
54S&F 150 mm dia bore PVC (SWR) pipes single socketedin any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.
55S&F 150mm dia bore PVC (SWR) bends complete all as specified and directed.
56S&F 150mm dia bore PVC (SWR) junction single, (single T) equal or unequal complete all as specified and directed.
57Dismantling of cast iron SWRpipes from any position of 100mm dia complete all as directed.
58S&F 110mm dia PVC (SWR) pipes single socketedin any length with rubber ring joints fixed to wall complete all as specified and as directed.
59S&F PVC (SWR) vent cowl 110mm dia all as specified and directed.
60S&F 110 mm dia PVC (SWR) Bend any radius complete all as specified and directed.
61S&F 110mm dia PVC (SWR) branch pieces double( double Y) equal or unequal all as specified and directed.
62S&F 110mm dia PVC (SWR) junction single ( single T) equal or unequalall as specified and directed.
63S&F 75mm dia PVC (SWR) floor trap plain with grating including jointing to waste pipe fixed in solvent cement or cement concrete 1:2:4 type B1all as in repairsspecified and directed.
64M&L for75 mm thick plain cement concrete (1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) as in plinth protection/ pathand fininshed even and fair without using extra cement complete all as specified and directed.
65S&F Chequered cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors including 15 mm thick screed bedding in CM 1:6. for laying floor finishes receiving floor tiles andgeay pigment cement and pigments in floorfinishes complete all as specified and directed.
66M & L Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed.
67S&F 2mm Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc complete all as specified and directed.
68Taking down Shutters of any descriptionexc 1 Sqmand n exc 2 sqm complete all as specified and directed.
69S&F for 30mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
70S&F Galvanised mildsteelwire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and as directed.
71S&F Grating doom 100 mm dia with waste hole of PTMT (Minimum weight 25gms)complete all as specified and directed.
72S&F in repairs door closer hydraulically cast iron regulated, designation No.3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixedcomplete all as specified and as directed.
73S&F 300 mm long aluminium alloy, anodized, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
74S&F Anodised aluminium frame for partition with one or more rebates including joining cleat for fixing including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and directed by Engr-in-Charge.
75S&F Figured glass 5.0mm thick, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete all as specified and directed.
76S&F Sheet glass 5.5mm thick, ordinary quality and glazing with rubber and complete accessoryin squareexc 0.5 sq. m in each complete all as specified and directed.
77S&F Anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and directed.
78S&F Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and directed by Engr-in-Charge.
79S&F in repairs curtain rails, mild steel, chromiumplated with fixing brackets, stops,rollers etccomplete all as specified and directed.
80Demolition of PCC block/ stone masonry built in cement mortarincluding allquoins, arches, pillars, etc, but including ashlar facings, dressed stonework and precast concrete articlesin any position complete all as specified and directed.
81M&L Precast cement concreteblock masonry type C-1 1:3:6 (20mm graded crushed stone aggregate) with solid blocks, exc. 10cm in width and, setting incement mortar 1:6 complete all as specified and as directed.
82M&L for preparing new surfaces of walls and appplying two coat of white wash complete all as specified and as directed.
83S&F Grid false ceiling GI system powder coted prelude, (Main Runner section 32x24x0.30x36mm, corss tee 25x24x0.30x1200mm, wall angle 24x24x0.40x3000mm and including providing fixing PVC pre-laminated in front side and aluminium foil backed gypsum tile board of size 595 x 595 x 8-9mm fixed in ceiling frame work with necesssary fastening GI wire and cleats complete all as specified and directed.
84Demolition of old unserviceable soakage well of any size and make good the surface by filling or removing debris/ Earth, complete all as specified and directed by Engr-in-Charge.
85Excavation over areas n.exc 1.5m deep and and getting out in hard/dense soil complete all as specified and as directed.
86Excavation over areas exc 1.5m deep and n.exc 3.00 m deep and getting out in hard/dense soil complete all as specified and as directed.
87Excavation over areas exc 3.0 deep and n.exc 4.5 m deep and getting out in hard/dense soil complete all as specified and as directed.
88M & L for PCC 1:3:6 type C-2 (Nominal Mix) using 40 mm graded crushed stone aggregateas in foundation filling mass concrete and similar work complete all as specified and as directed.
89M & L for Walling of random rubble uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6complete all as specified and directed
90M & L for Walling of random rubble stone masonary, uncoursed, well bonded, bedded and solidly hearted, laid drycomplete all as specified and directed
91Use and waste of rough finished formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) all as specified and directed.
92Use and waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roof n.exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10 cm but n.exc 20 cm wide complete all as specified and as directed.
93TMT steel bars 10mm dia and over (12mm), cut to length, bent to shape required, including cranking, bending spirally for hooping forcolumns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
94M & L for providing RCC type B-1 1:2:4 using 20 mm graded crushed stone aggregatein Slabs supported on walls, beams and columns in floors, roofs, landings,balconies, canopies, deck slabs and in shelves and the like all as specified and directed.
95M & Lfor precast cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in cover slab for manhole set in cement mortar 1:4 including necessary form work complete all as specified and directed
96Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m depth and n.exc 10 Sqm on plan and getting out in hard/dense soil complete all as specified and directed.
97Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed.
98Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed.
9915 mm thick renderingin cement mortar 1:3 (using water proofing compound) on PCC block walling or concrete surfaces and finished even and fair as specified and directed.
100M&L for Plain cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregate as in coping, benching bed plates and the line including necessaryform work and finishing all exposed surface of concrete as per clause 4.11.16.2(a) of SSR Part-I (2009) complete all as specified and directed.
101S&F 110mm dia bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to floors complete all as specified and as directed.
102M&L cement concrete bed 1:4:8 type D-2 (Using 40 mm graded crushed stone aggregate)to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested bore of pipe in 110 mm complete all as specified and as directed.
103Supply only Integral Water proofing compound complete all as specified.
104Taking down carefully alluminium / copper point wiring complete for light, fan, socket or power point etc with fittings fixtures such as ceiling rose, holders, electric fittings, switchs, sockets, aluminium conductor cable with and incl wooden batten or FR PVC conduit and its accessories such as wooden gutties, rawl plugs, GI screws, aluminium clips, nails etc complete and removing the material from site and making good the disturbed surface of wall / floor/ ceiling etc as original i.e. brick work, plastering, white washing, OBD etc as required, complete all as specified and directed.
105M&L point wiring complete with single core FRLS PVC insulated, unsheathed, multi stranded copper conductor cables 1.5 Sqmm 1100 volts grade, with and incl 1.5 Sqmm FRLS PVC insulated, unsheathed, multi stranded copper conductor cables as continuous earth wire connected to metallic bodies of luminaries / fans etc at one end and to common earth dolly at other end, complete wiring drawn through & PVC casingand cappingof 25 mm and above (as per conductor run ) medium grade, ISI marked, incl all accessories & fittings / junction boxes / inspection covers etc, with and including surface PVC Boxes of suitable size fixes with wall surface, gang box for top cover suitable for fixing of piano type switches / sockets etc, complete all as specified and directed for the following :-
106One light / bell / buzzer / exhaust fan point controlled by one no, 1-way, 5 Amps switch.
107One socket outlet 3 pin, 5 Amps on independent board, controlled by one no 5 Amp switch.
108One socket outlet 3 pin 5 Amps on the same board controlled by one NO. 5 Amp switch.
109All as per srl item no. 105.00 here-in-before but with 2.5 sq mmFRLS copper wire with 1.5 Sqmm FRLS copper earth wire for indpendent 15 Amp point.
110S&F, in replacement, of Switch piano type, single pole, one way, 5 amps, 230 volts, complete all as specified and directed.
111S&F, in replacement, of Switch Socket combination, two-in-one, 5 pin, 5 Amp, universal type, 230 volts, complete all as specified and directed.
112S&F, in replacement, of Switch piano type, single pole, one way, 15 amps, 230 volts, complete all as specified and directed.Make : Anchor / SSK / Leader
113S&F, in replacement, of Switch Socket combination, 6 pin, 5/15Amp, multipurpose shutter type, 230 volts, complete all as specified and directed.
114S&F, in replacement, of Ceiling rose, two to three terminals, bakelite body, 230 volts, complete all as specified and directed.
115Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
116S&F in replacement of LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete
117S & F LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
118S&F in replacement of angular lamp holder, PVC/Polycaronate type with back plate suitable for 9 watt LED bulb forbatten fittings complete all as specified and directed.
119S&F in replacement of 9W LED bulb complete all as specified.
120S&F in replacement of DB, double Door, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, SPN 4 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof, suitable for incorporation of MCB’s and isolators etc and making all necessary connections, duly flush of wall surface, complete all as specified and directed.
121S&F in replacement LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal anagement in multiple optics complete with IP 65/66 protection complete all as directed by Engr-in-Charge at site including necessary fixing arrangementlike bracket, clamps and nuts and bolts complete all as specified and as directed.
122S&F in replacement exhaust fans made of sturdy Engineering plastic AC single phase 230/ 240 V of size 250 mm sweep with louvre complete in cluding making hole in the wall and making good the disturbed surfaces complete all as directed.
123S&F in replacement of DB, double Door, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, SPN 8 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof, suitable for incorporation of MCB’s and isolators etc and making all necessary connections, duly flush of wall surface, complete all as specified and directed.
124S&F in replacement of MCB, C Curve type, 10 kA, 40 to 63 Amp, SPN with over load and short circuit protection, complete all as directed.
125S&F in replacement of MCB, C Curve type, 10 kA, 6 to 40 Amp, Single Pole with over load and short circuit protection, complete all as directed.
126M&L for sub main wiring with 2 run of 6 Sqmm FRLS, PVC insulated, unsheathed and stranded copper conductor cable with and incl 6 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable as earth wire connected with thimble from main DB to sub main DB, drawn in to separate, ISI marked, non metallic PVC conduit 20 mm dia size incl all conduit accessories & fittings / junction boxes / inspection covers etc, with and incl cutting chasing and making good of disturbed surface of wall / floor/ ceiling etc as original by brick work, plastering, white washing, OBD etc as required, complete all as directed. Note : 1. The cost of conduit & accessories is deemed to be included in quoted rates. 2. The two run of 6.00 Sqmm wire and one run of 6.00 Sqmm wire will be measured as one unit.
127Supply and laying XLPE insulated, armoured, heavy duty electric cable, with stranded aluminum conductor 1100 V grade nominal cross sectional area 10 Sqmm, 2 core laid in trenches, ducts, drawn through pipes across the road/path/along poles/wall/floors/equipment etc including jointing and testing complete all as specified and directed.
128Material and labour for un-reinforced pre-cast concrete cable covers, class LV type-1, flat size 250mm x 150mm x 40mm thick complete all as specified.
129Material and labour for sand cushioning to under ground electric cable all as per clause No 19.75 of MES SSR Part-I (2009) complete all as specified and as directed.
130M&L for earthing with galvanized steel earth plate electrode of size 600 x 600 x 6 mm buried directly in ground earth pit not less than 2.25 mtr below of normal ground level with top edge of earth plate should not less than 1.5 mtr below normal ground level and connected to galvanized iron earth lead wire of size 4 mm dia by means of bolts, nuts, washers of galvanized iron or steel all as shown in electrical plate No.3 of MES SSR Part I connecting to earthing test point on completion with and including 15 mm bore GI light grade protection pipe (7.5 mtr long) for earth lead GI lead wire 4mm dia (7.5 mtr long), PCC pit with cover in PCC 1:2:4 type B-1 reinforced with 8 mm dia tor bars @ 80mm C/C, 20mm dia medium grade watering pipe with funnel, wire mesh, common salt, charcoal, necessary excavation and earth work, complete all as specified and directed.