Tender For Provision Of Buildings For Mil Dental Centre (Type ‘C’) At Old Ge Amritsar, amritsar-Punjab

Military Engineer Services-MES has published Tender For Provision Of Buildings For Mil Dental Centre (Type ‘C’) At Old Ge Amritsar. Submission Date for this Tender is 21-10-2023. Building Work Tenders in amritsar Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

39230699
Corrigendum : Tender For Provision Of Buildings For Mil Dental Centre (Type ‘C’) At Old Ge Amritsar
Open Tender
Indian
Punjab
amritsar
21-10-2023

Tender Details

Provision Of Buildings For Mil Dental Centre ( Type ‘C’ ) At Old Ge Amritsar; 1 Lumpsum / Pre-Priced Provisional Schedules Of Works 2 Schedule A Part-I Building Works :-Lump Sum Price Worked Out By The Contractor For Building Of Mdc Type C Complete All As Specified And Shown On Drgs As Listed In Sch A Part I Brought Forward From Srl Page No 24. 3 Schedule ‘A’ Part-Ii Site Clearance, Excavaton And Earth Work :-Lump Sum Price Worked Out By The Contractor For Site Clearance, Excavation And Earth Work Complete All As Specified And Shown On Drgs As Listed In Sch A Part I Brought Forward From Srl Page No 25. 4 Schedule A Part-Iii “Parking Sheds” :-Lump Sum Price Worked Out By The Contractor For “Parking Sheds” As Listed In Schedule A Part-Iii Brought Forward From Serial Page No. 27 Complete All As Specified And Shown On Drgs. 5 Schedule A Part-Iv “Fire Fighting” :-Lump Sum Price Worked Out By The Contractor For “Fire Fighting” As Listed In Schedule A Part-Iv Brought Forward From Serial Page No. 29 Complete All As Specified And Shown On Drgs. 6 Schedule A Part-V “Sewage Disposal” :-Lump Sum Price Worked Out By The Contractor For “Sewage Disposal” As Listed In Schedule A Part-V Brought Forward From Serial Page No. 31 Complete All As Specified And Shown On Drgs. 7 Schedule A Part-Vi “Area Drainage” :-Lump Sum Price Worked Out By The Contractor For “Area Drainage” As Listed In Schedule A Part-Vi Brought Forward From Serial Page No. 32 Complete All As Specified And Shown On Drgs. 8 Schedule A Part-Vii “Chain Link Fencing” :-Lump Sum Price Worked Out By The Contractor For “Chain Link Fencing” As Listed In Schedule A Part-Vii Brought Forward From Serial Page No. 35 Complete All As Specified And Shown On Drgs. 9 Schedule A Part-Viii “External Water Supply” :-Lump Sum Price Worked Out By The Contractor For “External Water Supply” As Listed In Schedule A Part-Viii Brought Forward From Serial Page No. 37 Complete All As Specified And Shown On Drgs. 10 Schedule A Part-Ix “External Electric Supply” :-Lump Sum Price Worked Out By The Contractor For “External Electric Supply” As Listed In Schedule A Part-Ix Brought Forward From Serial Page No. 38 Complete All As Specified And Shown On Drgs. 11 Schedule A Part-X “Pvc Conduit” :-Lump Sum Price Worked Out By The Contractor For “Pvc Conduit” As Listed In Schedule A Part-X Brought Forward From Serial Page No. 39 Complete All As Specified And Shown On Drgs. 12 Schedule A Part-Xi “Earthing Equipment” :-Lump Sum Price Worked Out By The Contractor For “Earthing Equipment” As Listed In Schedule A Part-Xi Brought Forward From Serial Page No. 41 Complete All As Specified And Shown On Drgs. 13 Schedule A Part-Xii “Dg Sets” :-Lump Sum Price Worked Out By The Contractor For “Dg Sets”As Listed In Schedule A Part-Xii Brought Forward From Serial Page No. 43 Complete All As Specified And Shown On Drgs. 14 Schedule A Part-Xiii “Solar Water Heater” :-Lump Sum Price Worked Out By The Contractor For “Solar Water Heater” As Listed In Schedule A Part-Xiii Brought Forward From Serial Page No. 45 Complete All As Specified And Shown On Drgs. 15 Schedule A Part-Xiv “Cooling Appliances” :-Lump Sum Price Worked Out By The Contractor For “Cooling Appliances” As Listed In Schedule A Part-Xiv Brought Forward From Serial Page No. 46 Complete All As Specified And Shown On Drgs. 16 Schedule A Part Xv ( Miscellaneous Items ) 17 S&F For 15 Mm Bib Taps, With Sensor System Cast Copper Alloy Fancy Type Chromium Plated With Flange Screwed Down Screwed For Iron Pipe Of 15Mm Bore.Make- Jaquar Or Equivalent Approved By Ge. ( Cat Part No. Snr-Chr-35019Pm ) Complete All As Specified And Directed. 18 Supplying Laying In Trenches Jointing And Testing Dwcpe Pipes ( Sn8 ) 200 Od / 175 Od Mm Marked All As Specified And Directed. ( Excavation And Earthwork Shall Be Measured And Paid Seprately Under Appropriate Item Of Sch A ) 19 S&Ffor Pvc Coated Galvanized Iron Chain Link Fencing, Made Of Gi Wire Dia Not Less Than 3 Mm, And Minimum Dia 4.5 Mm After Pvc Coating, Having Any Mesh Size ( Mesh Size As Approved By Ge ) Including Line Wire, Any Type Of Standards, Rails, Straining Bolts, Etc Including Provission Of Binding Wire, Fixed As Knuckled Type Complete All As Specified And Directed By The Engineer-In-Charge. 20 Surface Excavation Not Exceeding30 Cm Deep And Averaging 15Cm Deep And Getting Outin Soft / Loose Soil, Separate The Roots / Grass And Good Earth By Sieving With Suitable Sieve Size , Stacking Of Good Earth & Mixed With Suitablemanure Of Ratio 5:1 Including Supply Of Manure, Screened Through Sieve Of 1.5 Designation 4.75 Mm And Spreading The Mixture Of Good Earth & Manure , Applying Suitable Pesticides , Watering To A Depth Of15cms, Including Removal Of Roots / Grass Out Of Site Complete All As Specified And Directed By The Garrison Engineer 21 Material And Labourfor Developing Lawn By Layingand Dibbling Of Grass Stealers OfDoob Grass Planting , Roofing Etc Complete As Approved And As Directed By The Garrison Engineer. 22 Supply & Labour For Developing And Planting Of Bottle Palmtree Of Height Not Less 4 Feet Including Exavation In Post Holes Of Size 60 Cm X 60 Cm X 60 Cm Or According To The Plant Size And Plant The Trees Straight Inside The Pit And Fill Up The Pit With The Earth Along With Inorganic Fertilise Manure ( Compost ) In The Proportion ( 3:1 ) And Remove And Spread The Surplus Excavated Soil Complete All As Specified And As Directed By The Engineer In Charge. 23 Supply & Labour For Developing And Planting Of Gulmohartree ( Delonix Regia ) Of Height Not Less 2 Feet Including Exavation In Post Holes Of Size 60 Cm X 60 Cm X 60 Cm Or According To The Plant Size And Plant The Trees Straight Inside The Pit And Fill Up The Pit With The Earth Along With Inorganic Fertilise Manure ( Compost ) In The Proportion ( 3:1 ) And Remove And Spread The Surplus Excavated Soil Complete All As Specified And As Directed By The Engineer In Charge. 24 Supply & Labour For Developing And Planting Of Amaltastree ( Cassia Fistula ) Of Height Not Less 2 Feet Including Exavation In Post Holes Of Size 60 Cm X 60 Cm X 60 Cm Or According To The Plant Size And Plant The Trees Straight Inside The Pit And Fill Up The Pit With The Earth Along With Inorganic Fertilise Manure ( Compost ) In The Proportion ( 3:1 ) And Remove And Spread The Surplus Excavated Soil Complete All As Specified And As Directed By The Engineer In Charge. 25 Supply & Labour For Developing And Planting Of Neem Tree ( Azadirachta Indica ) Of Height Not Less 3 Feet Including Exavation In Post Holes Of Size 90 Cm X 90 Cm X 90 Cm Or According To The Plant Size And Plant The Trees Straight Inside The Pit And Fill Up The Pit With The Earth Along With Inorganic Fertilise Manure ( Compost ) In The Proportion ( 3:1 ) And Remove And Spread The Surplus Excavated Soil Complete All As Specified And As Directed By The Engineer In Charge. 26 Material & Labour For Developing And Planting HedgesIncluding 60Cm Wide Laying And Dibbling Of Soil Rows And Watering , Including Excavation Post Holes For Plant As Required , Returning Filling With Earth In Necessary Watering And Finally Fine Dressing, Levelling Etc And Completeincluding Stacking And Disposal Of Materials Declared Unserviceable And Surplus Earth By Spreading And Levelling , The Distance Between Plants Not Exceeding 90Cms Complete All As Specified And As Directed By The Engineer In Charge. The Following Species For Hedges Shall Be Used:- ( A ) Ixora ( B ) Hibiscus ( C ) Goudi-Choudi ( D ) Plumbago ( E ) Nerium Oleander ( F ) Tecoma Capsensis Eranthemum Note: The Cost Of Earth, Royality, Manure & Item Transportation Is Deemed To Be Inlcuded In The Unit Rate Quoted. 27 M&L For Drilling And Tapping Ci / Di Water Mains Of 100 / 150 Mm Dia ( In Position ) For Branch Connections Of The Internal Dia 40 Mm Include For Turning Water Off And On And Draining And Refilling Complete All As Directed And Specified By Engineer-In-Charge. 28 Material And Labour For Construction Of Brick Masonary Pits ( 230Mm Thick Wall ) Of 900X600x1000mm Internal Dimension ( Bottom Pcc Floor Of The Pit Should Be Minimum 30Cms Below The Bottom Surface Of Sluice Valve Flange To Provide Sufficient Working Space ) , Bottom Floor Of The Pit Be Constructed In Pcc ( 1:4:8 ) Type D2 Using 15Cms Thick With 20Mm Stone Aggregate For Foundation, Brick Wall With Sub Class B Bricks Built In Cm 1:6, Inner And Exposed Surfaces And Bottom Floor Of The Pit Should Be Plastered In Cement Mortar ( 1:4 ) 15Mm Thick, Pcc 1:2:4 Type B1 Using 20Mm Graded Stone Aggregate For Coping. The Sluice Valve And Other Fittings Should Be Housed In Center Of The Pit. The Vertices Of The Pit Should In Right Angle And Chamfered. The Top Cover Of The Pit Will Be Made Out Of Ms Sheet 3Mm Thick With Angle Iron Frame Made Out Of Ms Angle 50Mmx50mmx6mm With Galvanized Steel Hinges Two Nos. And Locking Arrangements Duly Painted With Two Coats Of Water Resistant Synthetic Enameled Paint Over One Coat Of Red Oxide Including Necessary Excavation And Earth Work In Any Type Of Soil Complete All As Shown In Drg No. Cejz / Td-1060 Sheet 1 / 3 To 3 / 3. 29 Shifting Of Transformer 200 / 250 Kva From Extg Location To Mdc ( Within 1000 Mtrs ) Outdoor Type 11000 / 433 Volts, 3 Phase 4 Wire, 50 Cycle Naturally Oil Cooled Type Suitable For Outdoor Installation On Plinth Of Mdc Sub Stn Complete All As Specified And Directed By Engr-In-Charge.Note: ( A ) Rate Shall Be Inclusive Oftransformer Plinth Of Size 1.5X1.5X1.5 Mtr ( B ) The Safe Transformer Lifting From Extg Location, Shifting And Placing On New Plinth Is Contractors Responsibilty And Any Damage To Transformer In These Activities Will Be Entire Contractors Responsibilty And Contract Has To Make Good The Losses. ( C ) The Transformer Oil Will Be Filtered By The Contractor And Topping Of The Same Will Be Done By The Contractor Before Energysing The Transformer, Rate Quoted Shall Be Inclusive Of The Same. ( D ) The Existing Transformer Of Capacity 160 Kva Will Be Removed From Pole And Will Be Deposited To Thimayya Power House. 30 Supply And Fixing Double Compression Copper Gland For Fixing Armoured Cables Of Size 95 Sqmm 3 Core Nominal Cross Sectional Area Complete All As Directed 31 All As Per Ser Item No. 2.14 Above But Cross Sectional Area 120 Sqmm 3½ Core Complete All As Specified And Directed. 32 All As Per Ser Item No. 2.14 Above But Cross Sectional Area 70 Sqmm 3½ Core Complete All As Specified And Directed. 33 Supply & Laying Double Wall Corrugated ( Dwc ) High Density Poly Ethylene ( Hdpe ) Of Size 100Mm Dia Including All Necessary Fittings, Pn-4 Rating, Pressure 6 Kgf / Cm², Conforming To Is-16205 ( Part-24 ) With High Ring Stiffness & Cursh Resistance Capacity, Etc., Laid In Trench For Protection Of Submersible Flat Cable Complete All As Directed. 34 Supply, Install, Testing And Commissioning Of Lt Feeder Pillar Distribution Panel Board ( Kiosk ) Cpriapproved, Outdoor Type, Double Door ( Front & Rear Openable With Gasket Arround Doors ) , Weather / Vermin Proof Of Ip-54, Made Out Of 3.15Mm Thick Crca Mild Steel ( Certificate From Manufacturer Will Be Necessary For Quality Aasurance And Guarantee ) As Per Is:8623 Of Suitable Size And Medium Channel 75Mm Base Mounting Frame Of50mm X 50Mm X 5Mm, With Stainless Steel Hinges, Door Handles ( Front & Rear ) , Factory Assembled Cubicle Pattern Modular And Compartmentalized Construction, Floor Mounted Free Standing Type, 3 Phase And Neutral 500 Amps Current Carrying Capacity Aluminium Busbar With Epoxy Insulated Coating With Colour Sleeves And Including Incoming Acb And Outgoing Mccbs, Cable Galleries Inter Connecting Busbar Connection / Linkage With Countersunk Holes At Bottom For Base Mounting Brackets And Sheet Steel Gland Plates For Cable Entry Complete With The Following Accessories And Suitable For Housing One Incoming Mccb And Outgoing Mccbs Of Capacity As Below Complete And Mounting The Panel Board On Suitable Foundation With Pcc ( 1:3:6 ) , Bedding Upto A Height 45Cm Above Ground Level, Duly Grouted With Bolts, Nuts & Washers By Using Angle Iron Frame Of Size 50Mm X 50Mm X 6Mm Including Prewired With Suitable Size Pvc Insulated Copper Conductor Cable Not Less Than 2.5 Sqmm Complete All As Specified And Directed With The Following Accessories:- 35 Note: Panel Drg Will Be Got Approved From Ge By The Contractor Before Manufacturing. ( A ) Aluminium Busbar Duly Colour Code ( 04 Nos. ) - 1 Set ( B ) Mccb 4 Pole 320 Amps 36Ka At 415 V, Adjustable Thermal Magnetic Settings - 01 No. ( Incoming ) ( C ) Mccb 4 Pole 250 Amps 50Ka At 415 V, Adjustable Thermal Magnetic Settings - 01 No. ( Outgoing For Mdc ) ( D ) Mccb 4 Pole 100 Amps 25Ka At 415 V, Adjustable Thermal Magnetic Settings - 01 No. ( Spare ) ( E ) Ct Of Ratio Suitable Size Isi Marked - 1 Set ( Three Each ) ( F ) Digital Voltmeter With Selector Switch 0 To 500 Volts - 1 No. ( G ) Digital Ammeter With Selector Switch And Cts 0 To 500 Amps - 01 No. ( H ) Mf Meter 0-1 No. ( J ) Led Type Phase Indicator Lamps ( R 36 Ditto All As Per Item No. 2.18 Above But Consisting Of The Following:- ( A ) Aluminium Busbar Duly Colour Code ( 04 Nos. ) - 1 Set ( B ) Mccb 4 Pole 250 Amps 36Ka At 415 V, Adjustable Thermal Magnetic Settings - 01 No. ( Incoming ) ( C ) Mccb 4 Pole 80 Amps25ka At 415 V, Adjustable Thermal Magnetic Settings - 02 Nos. ( Outgoing ) ( D ) Mccb 4 Pole 63 Amps 25Ka At 415 V, Adjustable Thermal Magnetic Settings - 04 Nos. ( Outgoing & Spare ) ( E ) Ct Of Ratio Suitable Size Isi Marked - 1 Set ( Three Each ) ( F ) Digital Voltmeter With Selector Switch 0 To 500 Volts - 1 No. ( G ) Digital Ammeter With Selector Switch And Cts 0 To 500 Amps - 01 No. ( H ) Mf Meter 0-1 No. ( J ) Led Type Phase Indicator Lamps ( R 37 Frp Fencing To The Transformer Of Size 7.5 Mtrs X7.5 Mtrs X2 Mtr In Height Complete All As Specified And Directed. 38 Supply And Fixing Double Compression Copper Gland For Fixing Armoured Cables Of Size 120 Sqmm 3½ Core Nominal Cross Sectional Area Complete All As Directed 39 Supply & Laying Double Wall Corrugated ( Dwc ) High Density Poly Ethylene ( Hdpe ) Of Size 100Mm Dia Including All Necessary Fittings, Pn-4 Rating, Pressure 6 Kgf / Cm², Conforming To Is-16205 ( Part-24 ) With High Ring Stiffness & Cursh Resistance Capacity, Etc., Laid In Trench For Protection Of Submersible Flat Cable Complete All As Directed. 40 Supply, Install, Connect, Test And Commissioning Of Silent Diesel Engine Driven With Amf Panel Generating Set, Water Cooled Type, Bhp 156 @ 1500 Rpm, 6 Cylinder, Acoustic Proof, Comprising Diesle Engine As Per Is:10001 / 10002, Alternator As Per Is: 13364, Ac, 415 Volts, 50 Hz, 3 Phase 4 Wire, 125 Kva Capacity Coupled To Engine, Complete With Foundation ( As Per Oem Design ) , Installed / Fixed On Common Base Plate With Anti Vibration Pads / Friction Pads And Comprising:-A ) Battery Charger Of Suitable Capacity For Charging The Batteries Suitable For Operation On Ac 1-F, 230 Volts 50 Hzb ) Battery Of Suitable Capacity And Nos With Copper Flexible Pvc Insulated Cables And Terminals Lugs.C ) Initial Filing Of Engine Oil To Te Required Level / Standard.D ) Fuel Tank Capacity Not Less 8 Working Hours Fuel With Initial Filling Of Diesel Of Required Quantity For Testing The Dg Sete ) Digital Type Metre For Reading Volts, Amps, Frequency, Rpm, Hours Run, Kwh Etc., F ) Engine Safety Unit Indicator For Supply On, Low Lop, Battery Removed, High Tempareture, Fuse Open, V Belt Failed, Charge, Auxiliary Trip / Emergency Stop, Stop Solenoid On Etc., G ) Pressure Gauge 0-10 Bar, Tempareture Gauge, Ammeter 50-0-50, Indicator Lamp For Set On, Load On, Start Switch, Key Type On / Off Control.Note: ( A ) Electrical Load Test On Alternator Shall Be Carried Out At Site And All Arrangement To Carry Out The Load Test As Per Particular Specification Shall Be Made By The Contractor. ( B ) Diesel Oil For Testing Of Dg Set Shall Be Deemed To Be Included In The Rate Quoted. ( C ) Training To Department Staff Shall Be Given. ( D ) Aquostic Proof Enclosure Shall Conform To Central Pollution Control Board ( Cpcb ) Norms And Shall Be Carried Out By Authorised Manufacturers And Certificate To This Effect Shall Be Submitted. ( E ) Operation And Maintenance Manual And Test Certificate For Engine, Alternator And Acoustic Proof Enclosure. ( F ) Rate Quoted Sall Be Deemed To Have Been Inclusive Of Above 41 Supply, Install, Testing And Commissioning Of Refrigerator, Electric Driven, Single Phase, 230 Volts Ac, 50 Hz, Frost Free, Double Door, Copper Coil Material, Energy Efficient Bee 5 ( Five ) Star Rated Of Capacity More That 195 Ltrs Upto 310 Litres As Directed By Engr-In-Charge Including Refrigerator Mounting Stand Complete All As Specified And Directed 42 Supply And Install Voltage Stabilizer For Automatic Operation With Digital Voltmeter To Monitor In / Out Voltage With Time Delay And Bypass Switch, Single Phase, Thermal Overload Protection, Low & High Voltage Cut-Off Protection, Led Indication, Ic Controlled, Naturally Air Cooled Indoor Type And Design For Input Variation Between 170 Volts To 250 Volts With Output Output Voltage Stabilized At 230V With Accuracy Of + 2.5% And Of Capacity 2 Kva Complete All As Specified And Directed 43 All As Per Ser Item No. 2.26 Above But Of Capacity 5 Kva

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 12-Sep-2023 CORRIGENDUM NO 01 Date 28-09-2023
2 22-Sep-2023 CORRIGENDUM NO 02 Date 30-09-2023
3 23-Sep-2023 CORRIGENDUM BOQ 30-09-2023
4 23-Sep-2023 CORRIGENDUM NO 03 Other 30-09-2023
5 25-Sep-2023 CORRIGENDUM NO 04 Date 04-10-2023
6 26-Sep-2023 REVISED DRAWINGS 31 TO 45 Other 04-10-2023
7 26-Sep-2023 REVISED DRAWINGS 16 TO 30 Other 04-10-2023
8 26-Sep-2023 REVISED DRAWING 01 TO 15 SHEET Other 04-10-2023
9 26-Sep-2023 CORRIGENDUM Other 04-10-2023
10 26-Sep-2023 CORRIGENDUM NO 05 BOQ 04-10-2023
11 27-Sep-2023 CORRIGENDUM NO 06 Date 07-10-2023
12 07-Oct-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 14-10-2023
13 14-Oct-2023 CORRIGENDUM NO 07 Date 21-10-2023

Key Value

Document Fees
INR 1000 /-
EMD
INR 204000.0 /-
Tender Value
INR 1.29 Crore /-

BOQ Items

Name of Work : PROVN OF BLDGS FOR MIL DENTAL CENTRE (TYPE ‘C’) AT OLD GE AMRITSAR
Sl. No. Item Description
1LUMPSUM/PRE-PRICED PROVISIONAL SCHEDULES OF WORKS
2Schedule "A" Part-I BUILDING WORKS :- Lump sum price worked out by the contractor for building of MDC Type "C" complete all as specified and shown on drgs as listed in Sch A Part I brought forward from Srl Page No 24.
3SCHEDULE ‘A’ PART-II "SITE CLEARANCE, EXCAVATON AND EARTH WORK" :- Lump sum price worked out by the contractor for site clearance, excavation and earth work complete all as specified and shown on drgs as listed in Sch A Part I brought forward from Srl Page No 25.
4Schedule "A" Part-III “PARKING SHEDS” :- Lump sum price worked out by the contractor for “PARKING SHEDS” as listed in Schedule "A" Part-III brought forward from serial page No. 27 complete all as specified and shown on drgs.
5Schedule "A" Part-IV “FIRE FIGHTING” :- Lump sum price worked out by the contractor for “FIRE FIGHTING” as listed in Schedule "A" Part-IV brought forward from serial page No. 29 complete all as specified and shown on drgs.
6Schedule "A" Part-V “SEWAGE DISPOSAL” :- Lump sum price worked out by the contractor for “SEWAGE DISPOSAL” as listed in Schedule "A" Part-V brought forward from serial page No. 31 complete all as specified and shown on drgs.
7Schedule "A" Part-VI “AREA DRAINAGE” :- Lump sum price worked out by the contractor for “AREA DRAINAGE” as listed in Schedule "A" Part-VI brought forward from serial page No. 32 complete all as specified and shown on drgs.
8Schedule "A" Part-VII “CHAIN LINK FENCING” :- Lump sum price worked out by the contractor for “CHAIN LINK FENCING” as listed in Schedule "A" Part-VII brought forward from serial page No. 35 complete all as specified and shown on drgs.
9Schedule "A" Part-VIII “EXTERNAL WATER SUPPLY” :- Lump sum price worked out by the contractor for “EXTERNAL WATER SUPPLY” as listed in Schedule "A" Part-VIII brought forward from serial page No. 37 complete all as specified and shown on drgs.
10Schedule "A" Part-IX “EXTERNAL ELECTRIC SUPPLY” :- Lump sum price worked out by the contractor for “EXTERNAL ELECTRIC SUPPLY” as listed in Schedule "A" Part-IX brought forward from serial page No. 38 complete all as specified and shown on drgs.
11Schedule "A" Part-X “PVC CONDUIT” :- Lump sum price worked out by the contractor for “PVC CONDUIT” as listed in Schedule "A" Part-X brought forward from serial page No. 39 complete all as specified and shown on drgs.
12Schedule "A" Part-XI “EARTHING EQUIPMENT” :- Lump sum price worked out by the contractor for “EARTHING EQUIPMENT” as listed in Schedule "A" Part-XI brought forward from serial page No. 41 complete all as specified and shown on drgs.
13Schedule "A" Part-XII “DG SETS” :- Lump sum price worked out by the contractor for “DG SETS”as listed in Schedule "A" Part-XII brought forward from serial page No. 43 complete all as specified and shown on drgs.
14Schedule "A" Part-XIII “SOLAR WATER HEATER” :- Lump sum price worked out by the contractor for “SOLAR WATER HEATER” as listed in Schedule "A" Part-XIII brought forward from serial page No. 45 complete all as specified and shown on drgs.
15Schedule "A" Part-XIV “COOLING APPLIANCES” :- Lump sum price worked out by the contractor for “COOLING APPLIANCES” as listed in Schedule "A" Part-XIV brought forward from serial page No. 46 complete all as specified and shown on drgs.
16Schedule "A" Part XV (Miscellaneous items)
17S&F for 15 mm Bib taps,with sensor system cast copper alloy fancy type chromium plated with flange screwed down screwed for iron pipe of 15mm bore.Make- Jaquar or equivalent approved by GE.(Cat part No. SNR-CHR-35019PM) complete all as specified and directed.
18Supplying laying in trenches jointing and testing DWCPE pipes(SN8) 200 OD/175 OD mm marked all as specified and directed.(Excavation and earthwork shall be measured and paid seprately under appropriate Item of Sch A)
19S&Ffor PVC coated galvanized iron chain link fencing, made of GI wire dia not less than 3 mm, and minimum dia 4.5 mm after PVC coating, having any mesh size (mesh size as approved by GE) including line wire, any type of standards, rails, straining bolts, etc including provission of binding wire, fixed as knuckled type complete all as specified and directed by the Engineer-in-Charge.
20Surface excavation not exceeding30 cm deep and averaging 15cm deep and getting outin soft/loose soil, separate the roots/grass and good earth by sieving with suitable sieve size ,stacking of good earth & mixed with suitablemanure of ratio 5:1 including supply of manure,screened through sieve of 1.5 designation 4.75 mm and spreading the mixture of good earth & manure , applying suitable pesticides , watering to a depth of15cms, including removal of roots/grass out of site complete all as specified and directed by the Garrison Engineer
21Material and Labourfor developing Lawn by layingand dibbling of grass Stealers of"DOOB GRASS" planting , roofing etc complete as approved and as directed by the Garrison engineer.
22Supply & labour for developing and Planting of Bottle palmtree of height not less 4 feet including exavation in post holes of size 60 cm X 60 cm X 60 cm or according to the plant size and plant the trees straight inside the pit and fill up the pit with the earth along with inorganic fertilise manure (compost) in the proportion (3:1) and remove and spread the surplus excavated soil complete all as specified and as directed by the Engineer in Charge.
23Supply & labour for developing and Planting of Gulmohartree (Delonix regia)of height not less 2 feet including exavation in post holes of size 60 cm X 60 cm X 60 cm or according to the plant size and plant the trees straight inside the pit and fill up the pit with the earth along with inorganic fertilise manure (compost) in the proportion (3:1) and remove and spread the surplus excavated soil complete all as specified and as directed by the Engineer in Charge.
24Supply & labour for developing and Planting of Amaltastree (Cassia fistula)of height not less 2 feet including exavation in post holes of size 60 cm X 60 cm X 60 cm or according to the plant size and plant the trees straight inside the pit and fill up the pit with the earth along with inorganic fertilise manure (compost) in the proportion (3:1) and remove and spread the surplus excavated soil complete all as specified and as directed by the Engineer in Charge.
25Supply & labour for developing and Planting of Neem tree ( Azadirachta Indica) of height not less 3 feet including exavation in post holes of size 90 cm X 90 cm X 90 cm or according to the plant size and plant the trees straight inside the pit and fill up the pit with the earth along with inorganic fertilise manure (compost) in the proportion (3:1) and remove and spread the surplus excavated soil complete all as specified and as directed by the Engineer in Charge.
26Material & labour for developing and Planting "HEDGES"including 60cm wide laying and dibbling of Soil rows and watering , including excavation post holes for plant as required , returning filling with earth in necessary watering and finally fine dressing, levelling etc and completeincluding stacking and disposal of materials declared unserviceable and surplus earth by spreading and levelling , the distance between plants not exceeding 90cms complete all as specified and as directed by the Engineer in Charge. The following species for Hedges shall be used:- (a) Ixora (b) Hibiscus (c) Goudi-Choudi (d) Plumbago (e) Nerium Oleander (f)Tecoma Capsensis Eranthemum Note: The cost of earth, royality, manure & item transportation is deemed to be inlcuded in the unit rate quoted.
27M&L for drilling and tapping CI/DI water mains of 100/150 mm dia (in position) for branch connections of the internal dia 40 mm include for turning water off and on and draining and refilling complete all as directed and specified by Engineer-in-Charge.
28Material and labour for construction of brick masonary pits (230mm thick wall) of 900x600x1000mm internal dimension (bottom PCC floor of the pit should be minimum 30cms below the bottom surface of sluice valve flange to provide sufficient working space), bottom floor of the pit be constructed in PCC (1:4:8) type D2 using 15cms thick with 20mm stone aggregate for foundation, brick wall with sub class "B" bricks built in CM 1:6, inner and exposed surfaces and bottom floor of the pit should be plastered in cement mortar (1:4) 15mm thick, PCC 1:2:4 type B1 using 20mm graded stone aggregate for coping. The sluice valve and other fittings should be housed in center of the pit. The vertices of the pit should in right angle and chamfered. The top cover of the pit will be made out of MS sheet 3mm thick with angle iron frame made out of MS angle 50mmx50mmx6mm with galvanized steel hinges two Nos. and locking arrangements duly painted with two coats of water resistant synthetic enameled paint over one coat of red oxide including necessary excavation and earth work in any type of soil complete all as shown in Drg No. CEJZ/TD-1060 Sheet 1/3 to 3/3.
29Shifting of transformer 200/250 KVA from Extg location to MDC (within 1000 Mtrs) outdoor type 11000/433 volts, 3 phase 4 wire, 50 cycle naturally oil cooled type suitable for outdoor installation on plinth of MDC sub stn complete all as specified and directed by Engr-in-Charge. NOTE: (a)Rate shall be inclusive oftransformer plinth of size 1.5x1.5x1.5 mtr (b)The safe transformer lifting from extg location, shifting and placing on new plinth is contractors responsibilty and any damage to transformer in these activities will be entire contractors responsibilty and contract has to make good the losses. (c)The transformer oil will be filtered by the contractor and topping of the same will be done by the contractor before energysing the transformer, rate quoted shall be inclusive of the same. (d)The existing transformer of capacity 160 KVA will be removed from pole and will be deposited to Thimayya Power House.
30Supply and fixing double compression copper gland for fixing armoured cables of size 95 sqmm 3 core nominal cross sectional area complete all as directed
31All as per ser item No. 2.14 above but cross sectional area 120 sqmm 3½ core complete all as specified and directed.
32All as per ser item No. 2.14 above but cross sectional area 70 sqmm 3½ core complete all as specified and directed.
33Supply & laying double wall corrugated (DWC) high density poly ethylene (HDPE) of size 100mm dia including all necessary fittings, PN-4 rating, pressure 6 Kgf/cm², conforming to IS-16205 (Part-24) with high ring stiffness & cursh resistance capacity, etc., laid in trench for protection of submersible flat cable complete all as directed.
34Supply, install, testing and commissioning of LT feeder pillar distribution panel board (KIOSK) CPRIapproved, outdoor type, double door (front & rear openable with gasket arround doors), weather/vermin proof of IP-54, made out of 3.15mm thick CRCA mild steel (certificate from manufacturer will be necessary for quality aasurance and guarantee) as per IS:8623 of suitable size and medium channel 75mm base mounting frame of50mm x 50mm x 5mm, with stainless steel hinges, door handles (front & rear), factory assembled cubicle pattern modular and compartmentalized construction, floor mounted free standing type, 3 phase and neutral 500 amps current carrying capacity aluminium busbar with epoxy insulated coating with colour sleeves and including incoming ACB and outgoing MCCBs, cable galleries inter connecting busbar connection/linkage with countersunk holes at bottom for base mounting brackets and sheet steel gland plates for cable entry complete with the following accessories and suitable for housing one incoming MCCB and outgoing MCCBs of capacity as below complete and mounting the panel board on suitable foundation with PCC (1:3:6), bedding upto a height 45cm above ground level, duly grouted with bolts, nuts & washers by using angle iron frame of size 50mm x 50mm x 6mm including prewired with suitable size PVC insulated copper conductor cable not less than 2.5 sqmm complete all as specified and directed with the following accessories:-
35NOTE: Panel drg will be got approved from GE by the contractor before manufacturing. (a)Aluminium busbar duly colour code (04 Nos.) - 1 Set (b)MCCB 4 pole 320 Amps 36KA at 415 V, adjustable thermal magnetic settings - 01 No. (Incoming) (c)MCCB 4 pole 250 Amps 50KA at 415 V, adjustable thermal magnetic settings - 01 No. (Outgoing for MDC) (d)MCCB 4 pole 100 Amps 25KA at 415 V, adjustable thermal magnetic settings - 01 No. (Spare) (e)CT of ratio suitable size ISI marked - 1 Set (Three each) (f)Digital Voltmeter with selector switch 0 to 500 volts - 1 No. (g) Digital Ammeter with selector switch and CTs 0 to 500 amps - 01 No. (h) MF meter 0-1 No. (j)LED type phase indicator lamps (R
36Ditto all as per item No. 2.18 above but consisting of the following:- (a)Aluminium busbar duly colour code (04 Nos.) - 1 Set (b)MCCB 4 pole 250 Amps 36KA at 415 V, adjustable thermal magnetic settings - 01 No. (Incoming) (c)MCCB 4 pole 80 Amps25KA at 415 V, adjustable thermal magnetic settings - 02 Nos. (Outgoing) (d)MCCB 4 pole 63 Amps 25KA at 415 V, adjustable thermal magnetic settings - 04 Nos. (Outgoing & Spare) (e)CT of ratio suitable size ISI marked - 1 Set (Three each) (f)Digital Voltmeter with selector switch 0 to 500 volts - 1 No. (g) Digital Ammeter with selector switch and CTs 0 to 500 amps - 01 No. (h) MF meter 0-1 No. (j)LED type phase indicator lamps (R
37FRP fencing to the transformer of size 7.5 mtrs x7.5 mtrs x2 mtr in height complete all as specified and directed.
38Supply and fixing double compression copper gland for fixing armoured cables of size 120 sqmm 3½ core nominal cross sectional area complete all as directed
39Supply & laying double wall corrugated (DWC) high density poly ethylene (HDPE) of size 100mm dia including all necessary fittings, PN-4 rating, pressure 6 Kgf/cm², conforming to IS-16205 (Part-24) with high ring stiffness & cursh resistance capacity, etc., laid in trench for protection of submersible flat cable complete all as directed.
40Supply, install, connect, test and commissioning of Silent Diesel Engine driven with AMF panel Generating set, Water cooled type, BHP 156 @ 1500 RPM, 6 cylinder, Acoustic proof, comprising Diesle Engine as per IS:10001/10002, Alternator as per IS: 13364, AC, 415 Volts, 50 Hz, 3 phase 4 wire, 125 KVA capacity coupled to Engine, complete with foundation (as per OEM design), installed/fixed on common base plate with anti vibration pads/friction pads and comprising:- A)Battery charger of suitable capacity for charging the batteries suitable for operation on AC 1-f, 230 volts 50 Hz B)Battery of suitable capacity and Nos with copper flexible PVC insulated cables and terminals lugs. C)Initial filing of engine oil to te required level/standard. D)Fuel tank capacity not less 8 working hours fuel with initial filling of diesel of required quantity for testing the DG set E)Digital type Metre for reading volts, amps, frequency, RPM, hours run, KWH etc., F) Engine safety unit indicator for supply ON, low LOP, battery removed, high tempareture, fuse open, "V" Belt failed, charge, auxiliary trip/emergency stop, stop solenoid ON etc., G)Pressure gauge 0-10 bar, tempareture gauge, ammeter 50-0-50, indicator lamp for set ON, load ON, start switch, key type ON/OFF control. NOTE: (a)Electrical load test on alternator shall be carried out at site and all arrangement to carry out the load test as per particular specification shall be made by the contractor. (b)Diesel oil for testing of DG set shall be deemed to be included in the rate quoted. (c)Training to department staff shall be given. (d)Aquostic proof enclosure shall conform to Central Pollution Control Board (CPCB) norms and shall be carried out by authorised manufacturers and certificate to this effect shall be submitted. (e)Operation and Maintenance manual and test certificate for Engine, Alternator and Acoustic proof enclosure. (f)Rate quoted sall be deemed to have been inclusive of above
41Supply, install, testing and commissioning of refrigerator, electric driven, single phase, 230 volts AC,50 Hz, Frost free, Double door, copper coil material, energy efficient BEE 5 (five) star rated of capacity more that 195 ltrs upto 310 litres as directed by Engr-in-Charge including refrigerator mounting stand complete all as specified and directed
42Supply and install voltage stabilizer for automatic operation with digital voltmeter to monitor in/out voltage with time delay and bypass switch, single phase, thermal overload protection, low & high voltage cut-off protection, LED indication, IC controlled, naturally air cooled indoor type and design for input variation between 170 volts to 250 volts with output output voltage stabilized at 230V with accuracy of + 2.5% and of capacity 2 KVA complete all as specified and directed
43All as per ser item No. 2.26 above but of capacity 5 KVA
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail