Tender For Special Repair Of Safety Centre Building At Itr Chandipur, chandipur-Odisha

Military Engineer Services-MES has published Tender For Special Repair Of Safety Centre Building At Itr Chandipur. Submission Date for this Tender is 14-10-2023. Building Work Tenders in chandipur Odisha. Bidders can get complete Tender details and download the document.




Tender Notice

39211005
Corrigendum : Tender For Special Repair Of Safety Centre Building At Itr Chandipur
Open Tender
Indian
Odisha
chandipur
14-10-2023

Tender Details

Tender For Special Repair Of Safety Centre Building At Itr Chandipur; 1 Demolishing Brick Work In Cement Mortar Manually / By Mechanical Means Including Disposal Of Unserviceable Material Complete All As Specified And As Per Direction Of Engineer-In-Charge. 2 Demolishingcement Concrete Of Any Description And In Any Position Not Otherwisespecifically Provided For Manually / By Mechanical Means Including Disposal Of Material Complete All As Specified And As Per Direction Of Engineer - In - Charge 3 Dismantling Floor, Hearth Or Wall Tiling Including Cement Mortar Bedding ( But Notbacking ) , Removing Serviceable Tiles To Store And Rubbish Off The Premises Complete All As Specified And As Directed By Engineer In Charge. 4 Providing And Laying In Position Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 40 Mm Nominal Size ) Complete All As Specifed And As Directed By Engineer In Charge - All Work Up To Plinth Level 5 Providing And Laying Cement Concrete Pavement With 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , Including Finishingcomplete All As Specfied And As Dircted. 6 Providing And Filling In Position Rubberized Bitumen Hot Sealing Compound Using Grade A Sealing Compound Conforming To Is: 1834 For Sealing Of Expansion Joints In Roads / Pavements Complete All As Per Direction Of The Engineer-In-Charge. 7 M & L For Brickwork With Subclass ‘B’ Flyash Bricks, Straight Or Curved On Plan Exc 6M Mean Radius Built In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) Complete All As Specified And As Directed. 8 M & L For Brickwork With Subclass ‘B’ Flyash Bricks, Straight Or Curved On Plan To Any Radius In Half Brick Thick Walls Built In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) . 9 M & L For Treatment Of Soil Under Existing Floors Using Chemical Emulsion Chlorpyriphos / Lindane E.C. 20% With 1% Concentration @ One Litre Per Hole, 300 Mm Apart Including Drilling 12 Mm Diameter Holes And Plugging With Cement Mortar 1 :2 ( 1 Cement : 2 Coarse Sand ) To Match The Existing Floors Complete All As Specified And Directed. 10 Providing And Laying Double Charge Vitrified Tile Polished Finish Of Size 1000 X 1000 Mm In Floor ( Minimum 10Mm Thickness Or To Be Specified By The Manufacturer Which Ever Is Higher ) In Any Colour And Shade With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand & Manufacturer, In All Colours And Shade, Laid On 20 Mm Thick Cement Mortar 1:4 ( 1 Cement: 4 Coarse Sand ) Jointing With Grey Cement Slurry @3Kg / Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc. The Tiles Must Be Cut With The Zero Chipping Diamond Cutter Only . Laying Of Tiles Will Be Done With The Notch Trowel, Plier, Wedge, Clips Of Required Thickness, Leveling System And Rubber Mallet For Placing The Tiles Gently And Easily Complete All As Specified And Directed 11 Providing And Laying Double Charge Vitrified Tiles Polished Finish Of Size 600 X 600Mm ( Minimum 8-10Mm Thickness Or To Be Specified By The Manufacturer Which Ever Is Higher ) In Any Colour And Shade With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) , Jointing With Grey Cement Slurry @ 3 Kg / Sqm Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete All As Specified And Directed. 12 Providing And Laying Rectified Glazed Ceramic Floor Tiles Of Size 300X300mm Or More ( Minimum 8-10Mm Thickness Or To Be Specified By The Manufacturer Which Ever Is Higher ) , Of 1St Quality Conforming To Is : 15622, Of Approved Make, In Colours White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 ( 1 Cement: 4 Coarse Sand ) , Jointing With Grey Cement Slurry @ 3 Kg / Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete All As Specified And As Directed. 13 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Of Size 450X350mm Conforming To Is: 15622 ( Minimum 8Mm Thickness Or To Be Specified By The Manufacturer Which Ever Is Higher ) , Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. 14 Providing And Laying Polished Granite Stone Flooring Colour Of Black, Cherry / Ruby Red Or Equivalent In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18-20 Mm Thick Stone Slab Over 20 Mm ( Average ) Thick Base Of Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge 15 Providing And Fixing 18-20 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut Granite Stone Slab Colour Black, Cherry / Ruby Red For As In Skirting / Dado, Area Of Slab Upto 0.50 Sqm, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Completeat All Levels 16 Taking Down Old Plaster Or Skirting Including Raking Out Joints, Hacking For Key, Scrubbing Down With Water, Etc. And Cleaning The Surface For Plasterincluding Disposal Of Rubbish Complete All As Specifed And Directed By Engineer In Charge. 17 M & L For 15 Mm Thick Cement Plaster On Other Than Fair Finish Of Single Or Half Brick Wall Of Mix 1:6 ( 1 Cement: 6 Fine Sand ) Complete All As Specified And Directed. 18 M & L For 10 Mm Thick Cement Plasteron Other Side Of Fair Finish Single Or Half Brick Wall Of Mix1:3 ( 1 Cement : 3 Fine Sand ) Complete All As Specified And Directed. 19 M & L For 15 Mm Thick Cement Plasteron Rough Side Of Single Or Half Brick Wall Of Mix 1:4 ( 1 Cement: 4 Fine Sand ) Mixed With Wpc Complete All As Specified And Directed. ( Wpc Shall Me Measured Separately ) . 20 Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 21 M & L For Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade: New Work ( Two Or More Coats ) Over And Including Water Thinnable Priming Coat With Cement Primer Complete All As Specified And Directed By Engnieer In Charge. 22 M & L For Distempering With 1St Quality Acrylic Distember ( Ready Mix ) Having Voc Content Less Than 50 Grams / Litre Of Approved Brand And Manufacture To Give An Even Shade :Old Work ( One Or More Coats ) Complete All As Specifed And As Directed By Engineer In Charge. 23 M & L For Finishing New Plastered Surface Of Walls With Two Or More Coats 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm / Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Exterior Paint Of Required Shade With Silicon Additives @ 1.43 Litre / 10 Sqm. Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre / 10 Sqm Icluding Preparation Of New Plastered Surface Complete All As Specified And Directed. 24 M & L For Complete Removal Of Dry / Oil Bound Distemper / Water Proofing Cement Paint And The Like By Scrapping, Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches Etc And Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade: Old Work ( One Or More Coats Applied @ 0.83 Ltr / 10 Sqm ) Complete All As Specified And Directed By Engineer In Charge. 25 M & L For Roughening Surfaces Of Old Concrete Floors / Slabs Including Removing Existing Finishes If Any And Washing Down With Water To Remove Dust Particles Complete As Per Direction Of Engineer-In-Chargepecified And Directed . 26 M & L For Pcc On Roof 40Mm Thick For Water Proofing Treatment With Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand :4 Graded Stone Aggregate 20Mm Nominal Size ) Complete All As Specifed And As Directed. 27 M & L For Plaster On Roof 12Mm Thick For Water Proofing Treatment With Cement Mortar 1:4 ( 1Cement : 4 Coarse Sand ) Mixed With Water Proofing Compound ( Wpc ) ( Wpc Shall Be Measured Separately ) 28 M & L For Cutting Grooves In Brick / Concrete Wall 75 Mm Wide And 65 Mm Deep And Shaping Horizontal Of Grooves With Cement Mortar 1 : 3 Complete All As Specified And Directed . 29 Providing And Laying App ( Atactic Polypropylene Polymer ) Modified Prefabricated Five Layer 3 Mm Thick Water Proofing Membrane, Black Finished Reinforced With Non-Woven Polyester Matt Consisting Of A Coat Of Bitumen Primer For Bitumen Membrane @ 0.40 Litre / Sqm By The Same Membrane Manufacture Of Density At 25°C, 0.87-0.89 Kg / Litre And Viscocity 70-160 Cps. Over The Primer Coat The Layer Of Membrane Shall Be Laid Using Butane Torch And Sealing All Joints Etc, And Preparing The Surface Complete. The Vital Physical And Chemical Parameters Of The Membrane Shall Be As Under : Joint Strength In Longitudinal And Transverse Direction At 23°C As 650 / 450N / 5Cm. Tear Strength In Longitudinal And Transverse Direction As 300 / 250N. Softening Point Of Membrane Not Less Than 150°C. Cold Flexibility Shall Be Upto -2°C When Tested In Accordance With Astm, D - 5147. The Laying Of Membrane Shall Be Got Done Through The Authorised Applicator Of The Manufacturer Of Membrane Complete All As Specified And As Directed. 30 M & L For Painting With Aluminium Paint Of Approved Brand And Manufacture To Give An Even Shade .Two Or More Coats On New Surface Of App Membrane Complete All As Specfied And As Directed. 31 Supply Only Water Proofing Compound ( Wpc ) . 32 Dismantling Of Old S.W. Pipes 150Mm Diameter Including Breaking Of Joints And Bed Concrete And Disposal Of Unserviceable Materials Complete All As Specifed And As Directed. 33 Excavating Trenches In All Kind Of Soil Of Required Minimum Width As Per Ssr For Pipes, Cables, Etc Exceeding 80 Mm Dia But Not Exceeding 300 Mm Dia Including Excavation For Sockets, And Dressing Of Sides, Ramming Of Bottoms, Depth Upto 1.5 M, Including Getting Out The Excavated Soil, And Then Returning Filling The Soil As Required, In Layers Not Exceeding 20 Cm In Depth, Including Consolidating Each Deposited Layer By Ramming, Watering, Etc. And Disposing Of Surplus Excavated Soil As Directed Complete All As Specified. 34 Providing And Laying Concrete Bed To Drain Pipes Including Packing Under And Completely Surrounding Pipes With Concrete After They Are Laid And Tested; Incement Concrete 1:4:8 D2 ( 1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate ) All-Round 150 Mm Diameter Pipes Complete All As Specified And Directed. 35 Providing, Laying And Jointing Salt Glazed Stoneware Pipes 150 Mm Diameter Class Sp-1 With Stiff Mixture Of Cement Mortar In The Proportion Of 1:1 ( 1 Cement : 1 Fine Sand ) Including Testing Of Joints Etc. Complete All As Specified And Directed. 36 Providing And Fixing In Repair 15 Mm Nominal Bore C.P. Brass Bib Cock Of Approved Quality Conforming To Is:8931 Complete All As Specified And As Directed. 37 Providing And Fixing In Repair White Vitreous Wash Basin Size 550X400 Mm With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require Complete All As Specified And Directed 38 Providing And Fixing In Repair 15Mm Nominal Bore C.P. Brass Angle Valve Of Approved Quality Conforming To Is:8931 Complete All As Specified And Directed. 39 Providing And Fixing In Repair Uplasticised Pvc Connection Pipe 45Cm Long 15Mm Nominal Bore With Brass Unions Nuts Complete All As Specified. 40 Providing And Fixing White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440 Mm With Integral Type Foot Rests ( Indian Type W.C. ( Pan ) With 100 Mm Sand Cast Iron P Or S Trap, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device ( Handle Lever ) Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Dismantling W.C. Pan And Flushing Cistern Of All Sizes And Disposal Of Dismantled Materials I / E Malba, Cutting And Making Good The Walls And Floors Wherever Required All Complete As Per Directions Of Engineer-In-Charge. 41 Providing And Fixing White Vitreous China Pedestal Type Water Closet ( European Type W.C. Pan ) With White Solid Plastic Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device ( Handle Lever ) , Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Dismantling And Disposal Of Dismantled Materials I / E Malba, Cutting And Making Good The Walls And Floors Wherever Required All Complete As Per Directions Of Engineer-In-Charge. 42 S&F Cp Brass 2 Way Angle Cock With Flange Complete All As Specified And Directed 43 S & F In Repair, Cp Brass Health Faucet With 8Mm Dia, 1.2 Meter Long Flexibletube & Wall Hook Complete All As Specified And Directed 44 Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, 20 Mm Nominal Dia Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, I / C Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints And Including Dismantling Of Old Gi Pipe And Stacking Of Dismantled Pipes ( Within 50 Metres Lead ) Complete As Per Direction Of Engineerin-Charge. 45 Description Complete All As Per Item No 44 Here In Before But 25 Mm Nominal Dia. 46 Providing And Fixing Ball Valve 25 Mm Nominal Bore ( Brass ) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete All As Specified And As Directed 47 Providing And Fixing In Repair White Vitreous China Flat Back Single Half Stall Urinal With 5 Litre P.V.C. Automatic Flushing Cistern Of Size 580X380x350 Mm, With Fittings, Standard Size C.P. Brass Flush Pipe, Spreaders With Unions And Clamps ( All In C.P. Brass ) With Waste Fitting As Per Is : 2556, C.I. Trap With Outlet Grating And Other Couplings In C.P. Brass, Including Painting Of Fittings And Cutting And Making Good The Wallsand Floors Wherever Required Complete All As Specified 48 Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Single Socketed Pipes 75 Mm Diameter Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion, Including Dismantling 100Mm Dia Old C.I. Rain Water Pipe With Fittings And Clamps Including Stacking The Material Within 50 Metres Lead Complete All As Specified And Directed. 49 Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Bend 87.5° Of 75Mm Dia For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion 50 Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass ( Of Approved Quality ) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. 51 S & F In Repairs Towel Rail 600 Mm Long 20 Mm Dia, D Type Brass Chromium Plated Fixed To Wall With Cp Steel Screws Etc, Complete All As Specified And Directed. 52 Disconnecting Damaged Overhead / Terrace Pvc Water Storage Tank Of Any Size From Water Supply Line And Removing From The Terrace Including Shifting At Ground Level As Per Direction Of Engineer-In-Charge 53 Providing And Placing On Terrace ( At All Floor Levels ) Polyethylene Water Storage Tank 1000 Ltr Capacity, Is : 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank Complete All As Specified 54 Providing And Fixing Ptmt Extension Nipple 25Mm Nominal Bore, Weighing Not Less Than 62 Gms For Water Tank Pipe, Fittings Of Approved Quality And Colour Complete All As Specified. 55 Taking Town Doors, Windows And Clerestory Windows Shutters Any Description Of Area 3 Sq. Metres And Below Including Chowkhats, Architrave, Holdfasts Etc. Complete. 56 Providing Kiln Seasoned And Chemically Treated 2Nd Class Hard Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length ( Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately ) Complete All As Specified And As Directed. 57 Providing 40X5 Mm Flat Iron Hold Fast 40 Cm Long Including Fixing To Frame With 10 Mm Diameter Bolts, Nuts And Wooden Plugs And Embedding In Cement Concrete Block 30X10x15cm 1:3:6 Mix ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size ) Complete All As Diected By Engineer In Charge. 58 Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections / Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. ( Glazing, Paneling And Dash Fasteners To Be Paid For Separately ) : For Fixed Portion, Powder Coated Aluminium ( Minimum Thickness Of Powder Coating 50 Micron ) 59 Description Complete All As Per Item No 58 Here In Before But For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required ( Fittings Shall Be Paid For Separately ) , Powder Coated Aluminium ( Minimum Thickness Of Powder Coating 50 Micron ) 60 Providing And Fixing Anodised Aluminium Grill ( Anodised Transparent Or Dyed To Required Shade According To Is: 1868 With Minimum Anodic Coating Of Grade Ac 15 ) Of Approved Design / Pattern, With Approved Standard Section And Fixed To The Existing Window Frame With C.P. Brass / Stainless Steel Screws @ 200 Mm Centre To Centre, Including Cutting The Grill To Proper Opening Size For Fixing And Operation Of Handles And Fixing Approved Anodised Aluminium Standard Section Around The Opening, All Complete As Per Requirement And Direction Of Engineer-In-Charge. ( Only Weight Of Grill To Be Measured For Payment ) 61 Providing And Fixing 12 Mm Thick Prelaminated Particle Board With Decorative Lamination On One Side And Balancing Lamination On Other Side Flat Pressed Three Layer Or Graded Wood Particle Board Conforming To Is: 12823 Grade L Type Ll, In Panelling Fixed In Aluminum Doors, Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Directions Of Engineerin-Charge. 62 Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Directions Of Engineer-In-Charge, With Float Glass Panes Of 5 Mm Thickness ( Weight Not Less Than 12.50 Kg / Sqm ) Complete. 63 Description Complete All As Per Item No 62 Here In Before But With Frosted Glass Panes 4 Mm Thickness. 64 Providing And Fixing Brass 100Mm Mortice Latch And Lock With 6 Levers Without Pair Of Handles ( Best Make Of Approved Quality ) For Aluminium Doors Including Necessary Cutting And Making Good Etc. Complete All As Directed By Engineer In Charge. 65 Providing And Fixing 125Mm Aluminium Handles, Isi Marked, Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete All As Specified 66 Providing And Fixing Aluminium Hanging Twin Rubber Floor Door Stopper, Isi Marked, Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour And Shade, With Necessary Screws Etc. Complete All As Specified. 67 Providing And Fixing 300 X16mm Aluminium Sliding Door Bolts, Isi Marked Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) , Transparent Or Dyed To Required Colour Or Shade, With Nuts And Screws Etc. Complete All As Specified 68 Providing And Fixing 200 X 10Mm Aluminium Tower Bolts, Isi Marked, Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete. 69 Providing And Fixing 20 Mm Diameter Brass Curtain Rods Of Wall Thickness 1.25 Mm With Two Brass Brackets Fixed With Brass Screws And Wooden Plugs Etc. Wherever Necessary Complete All As Directed By Engineer In Charge. 70 Providing And Fixing Factory Made P.V.C. Door Frame Of Size 50X47 Mm With A Wall Thickness Of 5 Mm, Made Out Of Extruded 5Mm Rigid Pvc Foam Sheet, Mitred At Corners And Joined With 2 Nos Of 150 Mm Long Brackets Of 15X15 Mm M.S. Square Tube, The Vertical Door Frame Profiles To Be Reinforced With 19X19 Mm M.S. Square Tube Of 19 Gauge, Epdm Rubber Gasket Weather Seal To Be Provided Through Out The Frame. The Door Frame To Be Fixed To The Wall Using M.S. Screws Of 65 / 100 Mm Size, Complete As Per Manufacturer’S Specification And Direction Of Engineerin- Charge 71 Providing And Fixing 30Mm Thick Factory Made Panel Pvc Door Shutter Consisting Of Frame Made Out Of M.S. Tubes Of 19 Gauge Thickness And Size Of 19 Mm X 19 Mm For Styles And 15X15 Mm For Top & Bottom Rails. M.S. Frame Shall Have A Coat Of Steel Primers Of Approved Make And Manufacture. M.S. Frame Covered With 5 Mm Thick Heat Moulded Pvc C Channel Of Size 30 Mm Thickness, 70 Mm Width Out Of Which 50 Mm Shall Be Flat And 20 Mm Shall Be Tapered In 45 Degree Angle On Both Side Forming Styles And 5 Mm Thick, 95 Mm Wide Pvc Sheet Out Of Which 75Mm Shall Be Flat And 20 Mm Shall Be Tapered In 45 Degree On The Inner Side To Form Top And Bottom Rail And 115 Mm Wide Pvc Sheet Out Of Which 75 Mm Shall Be Flat And 20 Mm Shall Be Tapered On Both Sides To Form Lock Rail. Top, Bottom And Lock Rails Shall Be Provided Both Side Of The Panel. 10 Mm ( 5 Mm X 2 ) Thick, 20 Mm Wide Cross Pvc Sheet Be Provided As Gap Insert For Top Rail & Bottom Rail, Paneling Of 5 Mm Thick Both Side Pvc Sheet To Be Fitted In The M.S. Frame Welded / Sealed To The Styles & Rails With 7 Mm ( 5 Mm+2 Mm ) Thick X 15 Mm Wide Pvc Sheet Beading On Inner Side, And Joined Together With Solvent Cement Adhesive. An Additional 5 Mm Thick Pvc Strip Of 20 Mm Width Is To Be Stuck On The Interior Side Of The C Channel Using Pvc Solvent Adhesive Etc. Complete As Per Direction Of Engineer-In-Charge, ManufacturerS Specification & Drawing. 72 Dismantling Wooden Boardings Of Thickness Above 10 Mm Up To 25 Mmin Lining Of Walls And Partitions, Excluding Supporting Members And Removal Complete. 73 Providing And Fixing 19Mm Thick Both Side Balancing Lamination Factory Pressed Bwp Grade Marine Ply As Per Is 710 Of Approved Brand In Boxes, Shelves, Racks, Almirah, Cupboard And Drawer Etc. Including Necessary Nails, Screws Etc. Complete As Per Direction Of Engineer-In-Charge. 74 Providing And Fixing Aluminium Extruded Section Body Tubular Type Universal Hydraulic Door Closer ( Having Brand Logo With Isi, Is : 3564, Embossed On The Body, Door Weight Upto 36 Kg To 80 Kg And Door Width From 701 Mm To 1000 Mm ) , With Double Speed Adjustment With Necessary Accessories And Screws Etc. Complete All As Specified And As Directed. 75 Providing And Fixing In Position Collapsible Steel Shutters With Vertical Channels 20X10x2 Mm And Braced With Flat Iron Diagonals 20X5 Mm Size, With Top And Bottom Rail Of T-Iron 40X40x6 Mm, With 40 Mm Dia Steel Pulleys, Complete With Bolts, Nuts, Locking Arrangement, Stoppers, Handles, Including Applying A Priming Coat Of Approved Steel Primer. 76 Dismantling Steel Work In Built Up Sections In Angles, Tees, Flats And Channels Including All Gusset Plates, Bolts, Nuts, Cutting Rivets, Welding Etc. Including Dismembering And Stacking Within 50 Metres Lead 77 M & L For Steel Work Welded In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works Built Up Sections / Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required Complete All As Specified And As Directed. 78 Providing And Fixing Stainless Steel ( Grade 304 ) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature ( Wherever Required ) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I / C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-Incharge, ( For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc. ) 79 M & L For Finishing With Epoxy Paint ( Two Or More Coats ) On Steel Work At All Locations Prepared And Applied As Per ManufacturerS Specifications Including Appropriate Priming Coat, Preparation Of Surface, Etc. Complete As Per ManufacturerS Instructions And As Directed. 80 M & L For Painting With Synthetic Enamel Paint On Wood Surface Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade: Two Or More Coats On New Work Over An Under Coat Of Suitable Shade Of Primer Of Approved Brand And Manufacture Complete All As Specifed And As Directed. 81 M & L For Coal Tarring Two Coats On New Wood Work Using 0.16 Litre And 0.12 Litre Coal Tar Per Sqm In The First Coat And Second Coat Respectively Complete All As Specified And As Directed. 82 Providing, Hoisting And Fixing Above Plinth Level Up To Floor Five Level Precast Reinforced Cement Concrete Work In String Courses, Bands, Copings, Bed Plates, Anchor Blocks, Plain Window Sills, Cover Slabs And The Like, Including The Cost Of Required Centering, Shuttering But , Excluding Cost Of Reinforcement With 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size ) Complete All As Specified And As Directed. 83 S & F Steel Reinforcement Thermo-Mechanically Treated Bars ( Tmt ) Of Grade Fe-500D Or More For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding Complete All As Specified And As Directed.Above Plinth Level 84 Dismantling Cement Asbestos Or Other Hard Board Ceiling Or Partition Walls Including Stacking Of Serviceable Materials And Disposal Of Unserviceable Materials. 85 Providing And Fixing 12.5 Mm Thick Tapered Edge Gypsum Plain Board Conforming To Is: 2095- ( Part I ) :2011 ( Board With Bis Certification Marks ) Ceiling At All Height Including Providing And Fixing Of Frame Work Made Of Special Sections, Power Pressed From M.S. Sheets And Galvanized With Zinc Coating Of 120 Gms / Sqm ( Both Side Inclusive ) As Per Is : 277 And Consisting Of Angle Cleats Of Size 25 Mm Wide X 1.6 Mm Thick With Flanges Of 27 Mm And 37Mm, At 1200 Mm Centre To Centre, One Flange Fixed To The Ceiling With Dash Fastener 12.5 Mm Dia X 50Mm Long With 6Mm Dia Bolts, Other Flange Of Cleat Fixed To The Angle Hangers Of 25X10x0.50 Mm Of Required Length With Nuts & Bolts Of Required Size And Other End Of Angle Hanger Fixed With Intermediate G.I. Channels 45X15x0.9 Mm Running At The Spacing Of 1200 Mm Centre To Centre, To Which The Ceiling Section 0.5 Mm Thick Bottom Wedge Of 80 Mm With Tapered Flanges Of 26 Mm Each Having Lips Of 10.5 Mm, At 450 Mm Centre To Centre, Shall Be Fixed In A Direction Perpendicular To G.I. Intermediate Channel With Connecting Clips Made Out Of 2.64 Mm Dia X 230 Mm Long G.I. Wire At Every Junction, Including Fixing Perimeter Channels 0.5 Mm Thick 27 Mm High Having Flanges Of 20 Mm And 30 Mm Long, The Perimeter Of Ceiling Fixed To Wall / Partition With The Help Of Rawl Plugs At 450 Mm Centre, With 25Mm Long Dry Wall Screws @ 230 Mm Interval, Including Fixing Of Gypsum Board To Ceiling Section And Perimeter Channel With The Help Of Dry Wall Screws Of Size 3.5 X 25 Mm At 230 Mm C / C, Including Jointing And Finishing To A Flush Finish Of Tapered And Square Edges Of The Board With Recommended Jointing Compound , Jointing Tapes , Finishing With Jointing Compound In 3 Layers Covering Upto 150 Mm On Both Sides Of Joint And Two Coats Of Primer Suitable For Board, All As Per ManufacturerS Specification And Also Including The Cost Of Making Openings For Light Fittings, Grills, Diffusers, Cutouts Made With Frame Of Perimeter Channels Suitably Fixed, All Complete As Per Drawings, Specification And Direction Of The Engineer In Charge. 86 Supply And Fix 1St Quality Decorated Venetian Blind Of Any Design / Colour / Size As Approved By Engineer In Charge And Fixed With Bracket And Other Fixing Tools As Per Manufacturer Instruction Complete All As Specified And As Directed. 87 Taking Down Carefully Concealed Aluminum / Copper Point Wiring ( Light Fan Socket Or Power ) Complete Including Fixture And Fittings Such As Switches, Ceiling Roses, Pendants, Regulators Socket, Light Fittings Etc Removing Materials For Taking Creditand Making Good Disturbed Surfaces Of Wall, Floor, Etc. 88 M&L For Point Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With Pvc Insulated Unsheathed Stranded Frls Copper Conductor Cable Of Size 1.5 Sqmm, With Pvc Insulated Unsheathed Stranded Frls Copper Conductor Cable Of Size 1.5 Sqmm For Earth Continuity Wire, To Be Drawn In And Including Pvc Conduit Mediumduty With Concealed Wiring, Ms Sheet Metal Switch / Terminal Box 1.2 Mm Thick And Hylum Switch Board Cover 3.0 Mm Thickswitch Boardwith 5 / 6 A Pianoswitch Flush Type One Way 240 Vand Brass Screws With Cap Washers For One Light / Fan Point Controlled By One Single Way Switch Including All Necessarywall Cutting And Making Good Disturbed Surface Complete. 89 M&L For Power Plug For 15 Amp Independent Switch Socket Board With Pvc Insulated Unsheathed Stranded Frls Copper Conductor Cable Of Size 2X4 Sqmm, With Pvc Insulated Unsheathed Stranded Frls Copper Conductor Cable Of Size 1X4 Sqmm For Earth Continuity Wire, To Be Drawn In And Including Pvc Conduit Heavy Duty With Concealed Wiring Including All Necessarywall Cutting And Making Good Disturbed Surface 90 S& F Metal Boxes Of Size 75Mm X75mmx 60Mm Deep Of Thickness 1.2Mm On Surface Or Recess With Suitable Size Of Phenolic Laminated Sheet Cover Of Thickness 3Mm In Front Including Painting And Making Good Of Good Disturbed Surfaces 91 S& F Metal Boxes Of Size 100Mm X100mmx 60Mm Deep Of Thickness 1.2Mm On Surface Or Recess With Suitable Size Of Phenolic Laminated Sheet Cover Of Thickness 3Mm In Front Including Painting And Making Good Of Good Disturbed Surfaces 92 S& F Metal Boxes Of Size 150 Mm X75mmx 60Mm Deep Of Thickness 1.2Mm On Surface Or Recess With Suitable Size Of Phenolic Laminated Sheet Cover Of Thickness 3Mm In Front Including Painting And Making Good Of Good Disturbed Surfaces 93 S&Fsocket Outlet3 In 1, 5 Pin, 5 Amps Flush Type 240 Volt . 94 S&F Socket Outlet, 5 In 1 , 3 Pin 15 / 16 Amps Flush Type 240 Volt 95 S&Fswitch 5 / 6 Amps Flush Piano Type One Way 240 Volt . 96 S&Fswitch 15 / 16 Amps Flush Piano Type One Way 240 Volt . 97 S&F Ceiling Rose 5A, 3 Terminalpvc / Poly Carbonate Isolated Body On Existing Jucntion Box Including Connections Etc. As Required 98 S & Felectronic Fan Regulator, Stepped Type 120 / 280V 100Watt On Existing Phenolic Laminated Sheet Complete All As Directed By Engineer-In-Charge. 99 Taking Down Sub Main / Sub Circuit Wiring Of Any Type And Size Including Conduit / Casing Capping / Batten Wiring Complete All As Directed By Engineer-In-Charge. 100 M&L For Sub Main Wiring Usingtwo Runs Of Frls Grade Pvc Insulated, Unsheathed, Stranded, Copper Conductor Cable Of Size 2.5 Sqmm And One Run Of 2.5 Sqmm Frls Grade Pvc Insulated, Unsheathed, Stranded, Single Core, Copper Wire To Be Drawn In And Including At Least 25 Mm Size Pvc Conduit ( Medium Grade ) In Concealed Wiring Of Suitable Size Complete All As Specified And As Directed. ( Note:- 3 Run Of Copper Wire And Pvc Conduit Shall Be Measured As One Unit ) 101 M&L Sub Main Wiring Usingtwo Runs Of Frls Grade Pvc Insulated, Unsheathed, Stranded, Copper Conductor Cable Of Size 6.0 Sqmm And One Run Of 6.0 Sqmm Frls Grade Pvc Insulated, Unsheathed, Stranded, Single Core, Copper Wire To Be Drawn In And Includingat Least 25 Mm Size Pvc Conduit ( Medium Grade ) In Concealed Wiring Of Suitable Size Complete All As Specified And As Directed. ( Note:- 3 Run Of Copper Wire And Pvc Conduit Shall Be Measured As One Unit ) 102 M&L Sub Main Wiring Usingtwo Runs Of Frls Grade Pvc Insulated , Unsheathed , Stranded, Copper Conductor Cable Of Size 4 Sqmm And One Run Of 4 Sqmm Frls Grade Pvc Insulated, Unsheathed, Stranded, Single Core, Copper Wire To Be Drawn In And Including At Least 25 Mm Size Pvc Conduit ( Medium Grade ) In Concealed Wiring Of Suitable Size Complete All As Specified And As Directed. ( Note:- 3 Run Of Copper Wire And Pvc Conduit Shall Be Measured As One Unit ) 103 M&L Sub Main Wiring Usingfour Runs Of Frls Grade Pvc Insulated , Unsheathed , Stranded, Copper Conductor Cable Of Size 6 Sqmm And 2 Run Of 6 Sqmm Frlsh Grade Pvc Insulated, Unsheathed, Stranded, Copper Wire To Be Drawn In And Including Non Metallic Rigid Pvc Conduit Concealed In Wallincluding Cutting And Chassing The Wall As Per Site Requirement And Makinggood Disturbed Surface Of Walls Complete All As Specified And As Directed. ( Note:- 6 Run Of Copper Wire And Pvc Conduit Shall Be Measured As One Unit ) 104 M&L Sub Main Wiring Usingfour Runs Of Frls Grade Pvc Insulated , Unsheathed , Stranded, Copper Conductor Cable Of Size 10 Sqmm And 2 Run Of 10 Sqmm Frlsh Grade Pvc Insulated, Unsheathed, Stranded, Copper Wire To Be Drawn In And Including Non Metallic Rigid Pvc Conduit Concealed In Wallincluding Cutting And Chassing The Wall As Per Site Requirement And Makinggood Disturbed Surface Of Walls Complete All As Specified And As Directed. ( Note:- 6 Run Of Copper Wire And Pvc Conduit Shall Be Measured As One Unit ) 105 Supply And Fixing Of Following Ways Surface / Recess Mounting Vertical Type, 415 Volt Tpn Mcb8 Way ( 4 + 24 ) Double Door Distribution Board Of Sheet Steel, Dust Protested Duly Powder Painted, Inclusive Of 200 Amps Tinned Copper Bus Bar Common Neutral Link, Earth Bar, Din Bar For Mounting McbS ( But Without Mcb, S And Incommer ) As Required ( Note Vertical Type Mcb Tpdb Is Normally Used Where 3 Phase Outlets Are Required ) Includingtaking Down Old Db And Making Disturbed Surafce Good To Match The Existing Surface. 106 S & F Following Way Horizontal Type Three Pole And Neutral Sheet Steel, Mcb Distribution Board, 415 V, 4 Way ( 4 + 12 ) Double Door On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnection, Powder Painted Including Earthing Etc As Required ( But Without Mcb / Rccb / Isolator ) Including Making Good Disturbedsurfaces Including Taking Down Old Unserviceable , Complete All As Directed By Engineer-In-Charge. 107 S & F Following Way Single Pole And Neutral 8 Way Sheet Steel Mcb Distribution Board, 240 Volts On Surface / Recess Complete With Tinned Copper Bus Bar Neutral Bus Bar, Earth Bar, Din Bar, Interconnection, Powder Painted Including Earthing Etc, As Required ( But Without Mcb / Rccb / Isolator ) 108 Providng And Fixing 4 Pole 100 A, 30 Ka Fp Mccb With Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubilcle Panel, Making Connection Etc Ar Reuired. 109 S & F In Repair , Mcb, Tpn, 415 V, 50Hz, 16Ka, C Series, 63 Amps Series. 110 S & F 5A To 32 A Rating, 240V / 415 V, 10 Ka C Curve Miniature Circuit Breaker Triple Pole Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connection Testing And Commissioning Etc As Required. 111 S & F 5A To 32 A Rating, 240V / 415 V, 10 Ka C Curve Miniature Circuit Breaker Single Pole And Neutral Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connection Testing And Commissioning Etc As Required. 112 S & F 5A To 32 A Rating, 240V / 415 V, 10 Ka C Curve Miniature Circuit Breaker Single Pole Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connection Testing And Commissioning Etc As Required. 113 Supply And Fix Led Light Fitting 36 Watt Recess Mounting, Ultra Slim Edgelit Panel With Smd Led, Extrusion Aluminium Housing Anti Glare Diffuser, Recess Mountin 2Ftx2ft Square Typewith All Accessories Ip-20L Including Taking Down Old Us Cfl Fittings Any Type Complete All As Specified. 114 Supply And Fix Led Tube Light Fitting 2X20 Watt Decorative Batten With Smd Led, Retrofitted With T-8 Polycarbonate Tube Light Powder Coated Box Type Channel With All Accessories Including Taking Down Old Us Complete All As Specified 115 Supply And Fix Led Tube Light Fitting 1X20 Watt Decorative Batten With Smd Led, Retrofitted With T-8 Polycarbonate Tube Light Powder Coated Box Type Channel With All Accessories Including Taking Down Old Us Complete All As Specified 116 Supply And Fix Led Tube Light Fitting 10 Watt, 2 Ft Decorative Aluminium Extruded T5 Led Batten Integrated Typeincluding Taking Down Old Us Complete All As Specified 117 S&F In Repairled Security Light Fitting 45 Watt With All Accessories, ( With Extra Driver ) Attractively Styled High Pressure Die Cast Housing Acting As A Heat Sink Housingepoxy Powder Coated In Dark Graphite Greycolour Suitable For Mounting Bracket Of 40Mm Bore Gi Pipe Light Gradecomplete With All Accessoriesincludingtaking Down Old Fitting As Directed. 118 S & F 20A 240 V Spn Industrial Type Socket Outlet With 2 Pole And Earth Metal Enclosed Plug Top Alongwith 20 AC Sp, Mcb, In Sheet Steel Enclosure On Surface Or In Recess With Chined Metal Cover For The Socket Out Let And Complete With Connection Testing And Commissiong Etc As Required. 119 M&L Bus Bar Panel Of Capacity 200 Amps Copper Bus Bar 04 Noswith Fixed On Insulator Welded With Iron Angle Of Size 50X50x6 Mmthickgrounting In Floor, 0.45 Mm Depth Grounting With Pcc 1:3:6Upto Ground Level All As Specified And Directed. 120 M&L Earthing With Galvanized Steel Earth Plate Electrode Of Size 600 Mm X 600 Mm X 6 Mm Buried Directly In Ground Connected To Galvanized Earth Lead Strip Of Size 25 Mm X 4 Mm By Means Of Bolts, Nuts, Check Nuts And Washers Of Galvanized Iron Including 40Mm Dia Light Grade Gi Tubing For Protection Of Earth Lead, Ms Sheet Metal Funnel With Wire Mesh, Watering Pipe Light Grade 20Mm Dia, Charcoal Or Coke And Common Salt In Alternative Layers Of 15 Cm Compacted Thickness All Around The Electrode With Concrete Earth Pit With Pcc Type C1 , 1:3:6 ( Using 20 Mm Graded Stone Aggregate ) , 50Mm Thick Precast Rcc Type B1, ( 1:2:4 ) ( Using 20 Mm Graded Stone Aggregate ) Pit Cover Reinforced With 8Mm Dia Deformed Bar And Suitable Handle Made Of 10Mm Dia Round Bar Including Galvanised Strip Of Size 25Mm X 4Mm For Extension Of Earth Lead And Necessary Excavation, Earth Work, In Soft / Loose Soil And Disposal Of Spoils To A Distance Not Exc 50 Mtr And Necessary Connection And Testing Complete All As Shown In Electrical Plate No.3 Of Ssr Part-I, 2009 And All As Directed Including Taking Down Old Unserviceable One. ( Note :Gi Strip Upto 7.5 M Length Shall Be Deemed To Include In The Cost Of Above Item. 121 Supply And Laying Of One Number Pvc Insulated And Pvc Sheathed Xlpe Power Cable Of 1.1 Kv Grade Of 50 Sqmm 3.5 Core Size Direct On Wall With Shadling Screew, Washer Complete With All As Specified And Directed. 122 Taking Out Old Aluminium Strip From Wall / Roof Top And Keeping In Safe Custody For Re-Use And Taking Credit 123 Dismantling Of Pcc And Taking Out Air Termination Rodwith Gi Pipe Complete All As Directed By Engineer In Charge And Keeping In Safe Custody For Re-Use And Taking Credit 124 Providing And Fixing 25 Mm X 5 Mmcopper Strip On Surface Or In Recess For Connection Etc As Required Complete All As Specified And As Directed. 125 Fixing Only Single Pointed Air Terminal Aluminium Rod Of 12 Mm Dia 300Mm Long Complete All As Specified And Directed 126 Providing And Fixing Of Lightning Conductor Finial, Made Of 25 Mm Dia, 300 Mm Long, Gi Tube Medium Grade, Having Single 85Mm Dia And 6 Mm Thick Ms Base Plate Including Holes Etc Complete All As Direced By Engineer In Charge. 127 Providing And Fixing 25 Mm X 5 Mmgi Strip On Surface Or In Recess For Connection Etc As Required. 128 S & F Of Test Point Terminal Block Made Of Gun Metal Or Phosphorus Bronze Size 75X75x25 Mm Drilled And Screwed Including 3 Nos 8Mm Dia, 25Mm Long Hexa Head Screw Complete All As Directed. 129 M&L For Cement Concrete For Foundation Of Air Terminal 1:2:4 ( 1 Cement : 2 Coarse Sand : Graded Stone Aggregate 20 Mm Nomianl Size ) Complete All As Specified And As Directed. 130 Supply And Fixing Of Gi Pipe Light Grade For Air Terminal Ofsize 25Mm Dia Length As Per Site Requirment All As Spd And Directed. 131 Providing And Laying Gi Earth Strip 32 Mm X 6 Mm From Earth Electrode Directly In Ground As Required Complete All As Specified And Directed By Engineer In Charge. 132 Supply, Installation, Testing And Commissioning Of Basic Mr-2200 Series Intelligent Addressable Fire Alarm Control Panel Of Two Loop Provided Dual Intelligent Input Signaling Line Circuits For Upto 396 Devices And Programmable Cross Zoning ( 10 Zones Control ) Functions, Day / Night Mode And Selective Control Operations Complying With Bs En 54. 133 Supply, Installation, Testing And Commissioning Of Detectors Complying With And Type Certified To En-45 Addressable Type Smoke Detector Photoelectric / Optical With Intelligent Base With Self Built Intelligence As Per Is:11360 134 Description Complete All As Per Item No. 134 Here In Before But Addressible Type Analog Thermal Sensor ( Heat Detector ) With Intelligent Base With Rate Rise Cum Fixed Temperature As Per Is-2175 135 Supply, Installation, Testing And Commissioning Of Addressable Die Cast Double Action Manual Pull Station ( Manual Call Point ) With Surface Mount Back Box And Mini Monitor Complete All As Specified And Directed 136 Supply, Installation, Testing And Commissioning Of Fire Alarm Sounder With Facility To Make Annoucment Mounted In Ms Box ( 16 Swg ) With Hinged Cover Plate & Suitable For Operation With Amplifier I / C Line Matching Transformer Etc Compplete As Required. 137 Supply, Installation, Testing And Commissioningof Intelligent Audio Visual Strob With Base Complete All As Specified And Directed 138 Supply, Fixing And Testing Pvc Insulated Frls Copper Conductor Cable Twin Core 1.5 Sqmm Armoured 1100 Volts Drawn Throught And Including Suitable Size Of Stove Enamelled Steel Conduit Complete All As Specified And Directed 139 Gas Suppression Systemsupply, Installation, Testing And Commissioning Of Complete System Of Gas Suppression With 56 Kgs Fk-5-1-12 In One Cyclinder, Pneumatic Actuator, Tube, Magnetic Actuator, Check Valve, Pressure Guage Complete System All As Specified And Directed. 140 Supply And Fixing Nozzle Made Of Brass Of 56Mm Dia In Ms Tube Grid For Spreading Gas With Adquate Pressure Complete With All Connecting Accessories Complete All As Directed 141 Supply, Fixing And Making Grid Of Ms Tube 25 Mm And 15 Mm Dia Covering The Entire Room Including Making Hole In Wall / Ceiling And Making Good The Disturbed Surfaces With All Fittings Complete All As Specified And Directed 142 Supply, Installation, Testing And Commissioning Of Gas Suppression System Control Panel Complete With Smoke Detector, Heat Detector, Manual Call Point, Manual Release Abort Each 01 No Complete With Connecting With Standard Size Of Cable All As Specified And Directed

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 31-Aug-2023 corr01 Date 25-09-2023
2 18-Sep-2023 Corri02 Date 07-10-2023
3 27-Sep-2023 Corri03 BOQ 07-10-2023
4 07-Oct-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 14-10-2023

Key Value

Document Fees
INR 2000 /-
EMD
INR 266000.0 /-
Tender Value
INR 1.90 Crore /-

BOQ Items

NAME OF WORK : SPECIAL REPAIR OF SAFETY CENTRE BUILDING AT ITR CHANDIPUR.
Sl. No. Item Description
1Demolishing brick work in cement mortar manually/ by mechanical means including disposal of unserviceable material complete all as specified and as per direction of Engineer-in-charge.
2Demolishingcement concrete of any description and in any position not otherwise specifically provided for manually/ by mechanical means including disposal of material complete all as specified and as per direction of Engineer - in - charge
3Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by engineer in charge.
4Providing and laying in position cement concrete 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) complete all as specifed and as directed by engineer in charge - All work up to plinth level
5Providing and laying cement concrete pavement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete all as specfied and as dircted.
6Providing and filling in position rubberized bitumen hot sealing compound Using grade "A" sealing compound conforming to IS: 1834 for sealing of expansion joints in roads / pavements complete all as per direction of the Engineer-in-Charge.
7M & L for Brickwork with subclass ‘B’ flyash bricks, straight or curved on plan exc 6m mean radius built in Cement mortar 1:4 (1 cement : 4 coarse sand) complete all as specified and as directed.
8M & L for Brickwork with subclass ‘B’ flyash bricks, straight or curved on plan to any radius in half brick thick walls built in Cement mortar 1:4 (1 cement : 4 coarse sand).
9M & L for treatment of soil under existing floors using chemical emulsion Chlorpyriphos/ Lindane E.C. 20% with 1% concentration @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floors complete all as specified and directed.
10Providing and laying Double charge vitrified tile polished finish of size 1000 x 1000 mm in floor (minimum 10mm thickness or to be specified by the manufacturer which ever is higher) in any colour and shade with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily complete all as specified and directed
11Providing and laying double charge Vitrified tiles polished finish of size 600 x 600mm (minimum 8-10mm thickness or to be specified by the manufacturer which ever is higher) in any colour and shade with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3 kg/sqm including grouting the joint with white cement & matching pigments etc. complete all as specified and directed.
12Providing and laying rectified Glazed Ceramic floor tiles of size 300x300mm or more (minimum 8-10mm thickness or to be specified by the manufacturer which ever is higher), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete all as specified and as directed.
13Providing and fixing Ist quality ceramic glazed wall tiles of size 450x350mm conforming to IS: 15622 (minimum 8mm thickness or to be specified by the manufacturer which ever is higher), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
14Providing and laying Polished Granite stone flooring colour of Black, Cherry/Ruby Red or equivalent in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18-20 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge
15Providing and fixing 18-20 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut Granite stone slab colour black, Cherry/Ruby red for as in skirting/dado, Area of slab upto 0.50 sqm, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. completeat all levels
16Taking down old plaster or skirting including raking out joints, hacking for key, scrubbing down with water, etc. and cleaning the surface for plasterincluding disposal of rubbish complete all as specifed and directed by engineer in charge.
17M & L for 15 mm thick cement plaster on other than fair finish of single or half brick wall of mix 1:6 (1 cement: 6 fine sand) complete all as specified and directed.
18M & L for 10 mm thick cement plasteron other side of fair finish single or half brick wall of mix1:3 (1 cement : 3 fine sand) complete all as specified and directed.
19M & L for 15 mm thick cement plasteron rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) mixed with WPC complete all as specified and directed.(WPC Shall me measured separately).
20Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
21M & L for distempering with oil bound washable distemper of approved brand and manufacture to give an even shade: New work (two or more coats) over and including water thinnable priming coat with cement primer complete all as specified and directed by engnieer in charge.
22M & L for distempering with 1st quality acrylic distember (Ready mix) having VOC content less than 50 grams/ litre of approved brand and manufacture to give an even shade :Old work (one or more coats) complete all as specifed and as directed by engineer in charge.
23M & L for finishing new plastered surface of walls with two or more coats 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade with silicon additives @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm icluding preparation of new plastered surface complete all as specified and directed.
24M & L for complete removal of dry/oil bound distemper/water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc and finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: Old work (one or more coats applied @ 0.83 ltr/10 sqm) complete all as specified and directed by engineer in charge.
25M & L for roughening surfaces of old concrete floors / slabs including removing existing finishes if any and washing down with water to remove dust particles complete as per direction of Engineer-in-Chargepecified and directed .
26M & L for PCC on roof 40mm thick for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate 20mm nominal size) complete all as specifed and as directed.
27M & L for plaster on roof 12mm thick for water proofing treatment with Cement mortar 1:4 (1cement : 4 coarse sand) mixed with water proofing compound (WPC) (WPC Shall be measured separately)
28M & L for cutting grooves in Brick/concrete wall 75 mm wide and 65 mm deep and shaping horizontal of grooves with cement mortar 1 : 3 complete all as specified and directed .
29Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane complete all as specified and as directed.
30M & L for Painting with aluminium paint of approved brand and manufacture to give an even shade .Two or more coats on new surface of APP membrane complete all as specfied and as directed.
31Supply only water proofing compound (WPC).
32Dismantling of old S.W. pipes 150mm diameter including breaking of joints and bed concrete and disposal of unserviceable materials complete all as specifed and as directed.
33Excavating trenches in all kind of soil of required minimum width as per SSR for pipes, cables, etc exceeding 80 mm dia but not exceeding 300 mm dia including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning filling the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed complete all as specified.
34Providing and laying Concrete bed to drain pipes including packing under and completely surrounding pipes with concrete after they are laid and tested; incement concrete 1:4:8 D2 (1 cement : 4 coarse sand : 8 graded stone aggregate) all-round 150 mm diameter pipes complete all as specified and directed.
35Providing, laying and jointing salt glazed stoneware pipes 150 mm diameter class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete all as specified and directed.
36Providing and fixing in repair 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS:8931 complete all as specified and as directed.
37Providing and fixing in repair white vitreous wash basin size 550x400 mm with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require complete all as specified and directed
38Providing and fixing in repair 15mm nominal bore C.P. brass angle valve of approved quality conforming to IS:8931 complete all as specified and directed.
39Providing and fixing in repair uplasticised PVC connection pipe 45cm long 15mm nominal bore with brass unions nuts complete all as specified.
40Providing and fixing White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests (Indian type W.C. (pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including Dismantling W.C. Pan and flushing cistern of all sizes and disposal of dismantled materials i/e malba, cutting and making good the walls and floors wherever required all complete as per directions of Engineer-in-Charge.
41Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with white solid plastic seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including Dismantling and disposal of dismantled materials i/e malba, cutting and making good the walls and floors wherever required all complete as per directions of Engineer-in-Charge.
42S&F CP brass 2 way angle cock with flange complete all as specified and directed
43S & F in repair, CP brass Health faucet with 8mm dia, 1.2 Meter long flexibletube & wall hook complete all as specified and directed
44Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, 20 mm nominal dia having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints and including dismantling of old GI pipe and stacking of dismantled pipes (within 50 metres lead) complete as per direction of Engineerin-Charge.
45Description complete all as per item no 44 here in before but 25 mm nominal dia.
46Providing and fixing ball valve 25 mm nominal bore(brass) of approved quality, High or low pressure, with plastic floats complete all as specified and as directed
47Providing and fixing in repair white vitreous china flat back single half stall urinal with 5 litre P.V.C. automatic flushing cistern of size 580x380x350 mm, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the wallsand floors wherever required complete all as specified
48Providing and fixing on wall face unplasticised Rigid PVC rain water single socketed pipes 75 mm diameter conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, including Dismantling 100mm dia old C.I. rain water pipe with fittings and clamps including stacking the material within 50 metres lead complete all as specified and directed.
49Providing and fixing on wall face unplasticised - PVC moulded fittings/Bend 87.5° of 75mm dia for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion
50Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
51S & F in repairs towel rail 600 mm long 20 mm dia, D type Brass chromium plated fixed to wall with CP steel screws etc, complete all as specified and directed.
52Disconnecting damaged overhead/terrace PVC water storage tank of any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in-charge
53Providing and placing on terrace (at all floor levels) polyethylene water storage tank 1000 ltr capacity, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank complete all as specified
54Providing and fixing PTMT extension nipple 25mm nominal bore, weighing not less than 62 gms for water tank pipe, fittings of approved quality and colour complete all as specified.
55Taking town doors, windows and clerestory windows shutters any description of area 3 sq. metres and below including chowkhats, architrave, holdfasts etc. complete.
56Providing kiln seasoned and chemically treated 2nd class hard wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately) complete all as specified and as directed.
57Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) complete all as diected by engineer in charge.
58Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free,straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : for fixed portion, Powder coated aluminium (minimum thickness of powder coating 50 micron)
59Description complete all as per item No 58 here in before but for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately), Powder coated aluminium (minimum thickness of powder coating 50 micron)
60Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment)
61Providing and fixing 12 mm thick prelaminated particle board with decorative lamination on one side and balancing lamination on other side flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per directions of engineerin-charge.
62Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the directions of engineer-in-charge, with float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) complete.
63Description complete all as per item No 62 here in before but with frosted glass panes 4 mm thickness.
64Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete all as directed by engineer in charge.
65Providing and fixing 125mm aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete all as specified
66Providing and fixing aluminium hanging twin rubber floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete all as specified.
67Providing and fixing 300 x16mm aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete all as specified
68Providing and fixing 200 x 10mm aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete.
69Providing and fixing 20 mm diameter brass curtain rods of wall thickness 1.25 mm with two brass brackets fixed with brass screws and wooden plugs etc. wherever necessary complete all as directed by engineer in charge.
70Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer’s specification and direction of Engineerin- Charge
71Providing and fixing 30mm thick factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC "C" channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the "C" Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer"s specification & drawing.
72Dismantling wooden boardings of thickness above 10 mm up to 25 mmin lining of walls and partitions, excluding supporting members and removal complete.
73Providing and fixing 19mm thick both side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand in boxes, shelves, racks, almirah, cupboard and drawer etc. including necessary nails,screws etc. complete as per direction of Engineer-in-charge.
74Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete all as specified and as directed.
75Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer.
76Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead
77M & L for steel work welded in gratings, frames, guard bar, ladder, railings, brackets, gates and similar works built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required complete all as specified and as directed.
78Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
79M & L for finishing with Epoxy paint (two or more coats) on steel work at all locations prepared and applied as per manufacturer"s specifications including appropriate priming coat, preparation of surface, etc. complete as per manufacturer"s instructions and as directed.
80M & L for painting with synthetic enamel paint on wood surface of approved brand and manufacture of required colour to give an even shade: Two or more coats on new work over an under coat of suitable shade of primer of approved brand and manufacture complete all as specifed and as directed.
81M & L for coal tarring two coats on new wood work using 0.16 Litre and 0.12 litre coal tar per sqm in the first coat and second coat respectively complete all as specified and as directed.
82Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills, cover slabs and the like, including the cost of required centering, shuttering but , excluding cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) complete all as specified and as directed.
83S & F Steel reinforcement Thermo-Mechanically Treated bars (TMT) of grade Fe-500D or more for R.C.C. work including straightening, cutting, bending, placing in position and binding complete all as specified and as directed.above plinth level
84Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials.
85Providing and fixing 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge.
86Supply and fix 1st Quality decorated venetian blind of any design/colour/size as approved by Engineer in Charge and fixed with bracket and other fixing tools as per manufacturer instruction complete all as specified and as directed.
87Taking down carefully concealed aluminum/copper point wiring (Light fan socket or power)complete including fixture and fittings such as switches, ceiling roses, pendants, regulators socket, light fittings etc removing materials for taking creditand making good disturbed surfaces of wall, floor, etc.
88M&L for point wiring for light point/fan point/exhaust fan point/call bell point with PVC insulated unsheathed stranded FRLS copper conductor cable of size 1.5 Sqmm, with PVC insulated unsheathed stranded FRLS copper conductor cable of size 1.5 Sqmm for earth continuity wire, to be drawn in and including PVC conduit mediumduty with concealed wiring, MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thickswitch boardwith 5/6 A pianoswitch flush type one way 240 Vand brass screws with cap washers for one light/Fan point controlled by one single way switch including all necessarywall cutting and making good disturbed surface complete.
89M&L for power plug for 15 Amp Independent switch socket board with PVC insulated unsheathed stranded FRLS copper conductor cable of size 2x4 Sqmm, with PVC insulated unsheathed stranded FRLS copper conductor cable of size 1x4 Sqmm for earth continuity wire, to be drawn in and including PVC conduit heavy duty with concealed wiring including all necessarywall cutting and making good disturbed surface
90S& F metal boxes of size 75mm x75mmx 60mm deep of thickness 1.2mm on surface or recess with suitable size of phenolic laminated sheet cover of thickness 3mm in front including painting and making good of good disturbed surfaces
91S& F metal boxes of size 100mm x100mmx 60mm deep of thickness 1.2mm on surface or recess with suitable size of phenolic laminated sheet cover of thickness 3mm in front including painting and making good of good disturbed surfaces
92S& F metal boxes of size 150 mm x75mmx 60mm deep of thickness 1.2mm on surface or recess with suitable size of phenolic laminated sheet cover of thickness 3mm in front including painting and making good of good disturbed surfaces
93S&FSocket outlet3 in 1, 5 pin, 5 Amps flush type 240 Volt .
94S&F socket Outlet, 5 in 1 ,3 pin 15/16 amps flush type 240 Volt
95S&Fswitch 5/6 Amps flush piano type one way 240 Volt .
96S&Fswitch 15/16 Amps flush piano type one way 240 Volt .
97S&F Ceiling rose 5A, 3 terminalPVC/poly carbonate isolated body on existing jucntion box including connections etc. as required
98S & FElectronic fan regulator, stepped type 120/280V 100Watt on existing phenolic laminated sheet complete all as directed by Engineer-in-Charge.
99Taking down Sub main /Sub circuit wiring of any type and size including conduit / casing capping / batten wiring complete all as directed by Engineer-in-Charge.
100M&L for Sub main wiring usingtwo runs of FRLS grade PVC insulated, unsheathed, stranded, copper conductor cable of size 2.5 Sqmm and one run of 2.5 Sqmm FRLS grade PVC insulated, unsheathed, stranded, single core, copper wire to be drawn in and including at least 25 mm size PVC Conduit (medium grade) in Concealed wiring of suitable size complete all as specified and as directed. (Note:- 3 run of copper wire and PVC conduit shall be measured as one unit)
101M&L Sub main wiring usingtwo runs of FRLS grade PVC insulated, unsheathed, stranded, copper conductor cable of size 6.0 Sqmm and one run of 6.0 Sqmm FRLS grade PVC insulated, unsheathed, stranded, single core, copper wire to be drawn in and includingat least 25 mm size PVC Conduit (medium grade) in Concealed wiring of suitable size complete all as specified and as directed. (Note:- 3 run of copper wire and PVC conduit shall be measured as one unit)
102M&L Sub main wiring usingtwo runs of FRLS grade PVC insulated ,unsheathed ,stranded, copper conductor cable of size 4 Sqmm and one run of 4 Sqmm FRLS grade PVC insulated, unsheathed, stranded, single core, copper wire to be drawn in and including at least 25 mm size PVC Conduit (medium grade) in Concealed wiring of suitable size complete all as specified and as directed. (Note:- 3 run of copper wire and PVC conduit shall be measured as one unit)
103M&L Sub main wiring usingfour runs of FRLS grade PVC insulated ,unsheathed ,stranded, copper conductor cable of size 6 Sqmm and 2 run of 6 Sqmm FRLSH grade PVC insulated, unsheathed, stranded, copper wire to be drawn in and including non metallic rigid PVC conduit concealed in wallincluding cutting and chassing the wall as per site requirement and makinggood disturbed surface of walls complete all as specified and as directed. (Note:- 6 run of copper wire and PVC conduit shall be measured as one unit)
104M&L Sub main wiring usingfour runs of FRLS grade PVC insulated ,unsheathed ,stranded, copper conductor cable of size 10 Sqmm and 2 run of 10 Sqmm FRLSH grade PVC insulated, unsheathed, stranded, copper wire to be drawn in and including non metallic rigid PVC conduit concealed in wallincluding cutting and chassing the wall as per site requirement and makinggood disturbed surface of walls complete all as specified and as directed. (Note:- 6 run of copper wire and PVC conduit shall be measured as one unit)
105Supply and fixing of following ways surface/recess mounting vertical type, 415 volt TPN MCB8 way (4 + 24 ) double door distribution board of sheet steel, dust protested duly powder painted, inclusive of 200 amps tinned copper bus bar common neutral link, earth bar, din bar for mounting MCB"s (but without MCB,s and incommer ) as required (Note Vertical type MCB TPDB is normally used where 3 phase outlets are required) includingtaking down old DB and making disturbed surafce good to match the existing surface.
106S & F following way horizontal type three pole and neutral sheet steel, MCB distribution board, 415 V, 4 way ( 4 + 12) double door on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnection, powder painted including earthing etc as required ( but without MCB/RCCB/Isolator) including making good disturbedsurfaces including taking down old unserviceable , complete all as directed by Engineer-in-Charge.
107S & F following way single pole and neutral 8 way sheet steel MCB distribution board, 240 volts on surface/recess complete with tinned copper bus bar neutral bus bar, earth bar, din bar, interconnection, powder painted including earthing etc, as required (but without MCB/RCCB/Isolator)
108Providng and fixing 4 pole 100 A, 30 KA FP MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubilcle panel, making connection etc ar reuired.
109S & F in repair , MCB, TPN, 415 V, 50Hz, 16kA, "C" series, 63 Amps series.
110S & F 5A to 32 A rating, 240V/415 V, 10 kA "C" curve miniature circuit breaker triple pole suitable for inductive load of following poles in the existing MCB DB complete with connection testing and commissioning etc as required.
111S & F 5A to 32 A rating, 240V/415 V, 10 kA "C" curve miniature circuit breaker single pole and neutral suitable for inductive load of following poles in the existing MCB DB complete with connection testing and commissioning etc as required.
112S & F 5A to 32 A rating, 240V/415 V, 10 kA "C" curve miniature circuit breaker single pole suitable for inductive load of following poles in the existing MCB DB complete with connection testing and commissioning etc as required.
113Supply and fix LED light fitting 36 Watt recess mounting, ultra slim edgelit panel with SMD LED, extrusion aluminium housing anti glare diffuser, recess mountin 2ftx2ft square typewith all accessories IP-20l including taking down old us CFL fittings any type complete all as specified.
114Supply and fix LED tube light fitting 2x20 Watt decorative batten with SMD LED, retrofitted with T-8 polycarbonate tube light powder coated box type channel with all accessories including taking down old us complete all as specified
115Supply and fix LED tube light fitting 1x20 Watt decorative batten with SMD LED, retrofitted with T-8 polycarbonate tube light powder coated box type channel with all accessories including taking down old us complete all as specified
116Supply and fix LED tube light fitting 10 Watt, 2 ft decorative aluminium extruded T5 LED Batten integrated typeincluding taking down old us complete all as specified
117S&F in repairLED security light fitting 45 Watt with all accessories, (with extra driver) attractively styled high pressure die cast housing acting as a heat sink housingepoxy powder coated in dark graphite greycolour suitable for mounting bracket of 40mm bore GI pipe light gradecomplete with all accessoriesincludingtaking down old fitting as directed.
118S & F 20A 240 V SPN industrial type socket outlet with 2 pole and earth metal enclosed plug top alongwith 20 A"C" SP, MCB, in sheet steel enclosure on surface or in recess with chined metal cover for the socket out let and complete with connection testing and commissiong etc as required.
119M&L Bus Bar Panel of capacity 200 Amps copper bus bar 04 Noswith fixed on insulator welded with iron angle of size 50x50x6 mmthickgrounting in floor, 0.45 mm depth grounting with PCC 1:3:6upto ground level all as specified and directed.
120M&L Earthing with galvanized steel earth plate electrode of size 600 mm x 600 mm x 6 mm buried directly in ground connected to galvanized earth lead strip of size 25 mm x 4 mm by means of bolts, nuts, check nuts and washers of galvanized iron including 40mm dia light grade GI tubing for protection of earth lead, MS sheet metal funnel with wire mesh, watering pipe light grade 20mm dia, charcoal or coke and common salt in alternative layers of 15 cm compacted thickness all around the electrode with concrete earth pit with PCC type C1 , 1:3:6 (using 20 mm graded stone aggregate),50mm thick precast RCC type B1, (1:2:4)(using 20 mm graded stone aggregate) pit cover reinforced with 8mm dia deformed bar and suitable handle made of 10mm dia round bar including galvanised strip of size 25mm x 4mm for extension of earth lead and necessary excavation, earth work, in soft/loose soil and disposal of spoils to a distance not exc 50 mtr and necessary connection and testing complete all as shown in electrical plate No.3 of SSR Part-I, 2009 and all as directed including taking down old unserviceable one. (Note :GI strip upto 7.5 m length shall be deemed to include in the cost of above item.
121Supply and Laying of one number PVC insulated and PVC sheathed XLPE power cable of 1.1 KV grade of 50 sqmm 3.5 core size direct on wall with shadling screew, washer complete with all as specified and directed.
122Taking out old Aluminium strip from wall/roof top and keeping in safe custody for re-use and taking credit
123Dismantling of PCC and taking out Air termination rodwith GI Pipe complete all as directed by engineer in charge and keeping in safe custody for re-use and taking credit
124Providing and fixing 25 mm x 5 mmcopper strip on surface or in recess for connection etc as required complete all as specified and as directed.
125Fixing only Single pointed air terminal Aluminium rod of 12 mm dia 300mm long complete all as specified and directed
126Providing and fixing of lightning conductor finial, made of 25 mm dia, 300 mm long, GI tube medium grade, having single 85mm dia and 6 mm thick MS base plate including holes etc complete all as direced by engineer in charge.
127Providing and fixing 25 mm x 5 mmGI strip on surface or in recess for connection etc as required.
128S & F of Test Point terminal block made of Gun Metal or Phosphorus Bronze size 75x75x25 mm drilled and screwed including 3 Nos 8mm dia, 25mm long Hexa head screw complete all as directed.
129M&L for cement concrete for foundation of Air Terminal 1:2:4 (1 cement : 2 coarse sand : graded stone aggregate 20 mm nomianl size) complete all as specified and as directed.
130Supply and fixing of GI pipe light grade for Air terminal ofsize 25mm dia length as per site requirment all as spd and directed.
131Providing and laying GI earth strip 32 mm x 6 mm from earth electrode directly in ground as required complete all as specified and directed by engineer in charge.
132Supply, installation, testing and commissioning of Basic MR-2200 SERIES intelligent Addressable Fire Alarm Control Panel of two loop provided dual intelligent input signaling line circuits for upto 396 Devices and programmable cross zoning(10 Zones Control) functions, day/night mode and selective control operations complying with BS EN 54.
133Supply, installation, testing and commissioning of detectors complying with and type certified to EN-45 addressable type smoke detector photoelectric/optical with Intelligent Base with self built intelligence as per IS:11360
134Description complete all as per item No. 134 here in before but addressible type analog thermal sensor (heat detector) with intelligent base with rate rise cum fixed temperature as per IS-2175
135Supply, installation, testing and commissioning of addressable Die cast double action Manual pull station (manual call point) with surface mount Back box and mini Monitor complete all as specified and directed
136Supply, installation, testing and commissioning of fire alarm sounder with facility to make annoucment mounted in MS box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc compplete as required.
137Supply, installation, testing and commissioningof intelligent audio visual strob with base complete all as specified and directed
138Supply, fixing and testing PVC insulated FRLS copper conductor cable twin core 1.5 sqmm armoured 1100 volts drawn throught and including suitable size of stove enamelled steel conduit complete all as specified and directed
139GAS SUPPRESSION SYSTEM Supply, installation, testing and commissioning of complete system of gas suppression with 56 kgs FK-5-1-12 in one cyclinder, pneumatic actuator, tube, magnetic actuator, check valve, pressure guage complete system all as specified and directed.
140Supply and fixing nozzle made of brass of 56mm dia in MS tube grid for spreading gas with adquate pressure complete with all connecting accessories complete all as directed
141Supply, fixing and making grid of MS tube 25 mm and 15 mm dia covering the entire room including making hole in wall/ceiling and making good the disturbed surfaces with all fittings complete all as specified and directed
142Supply, installation, testing and commissioning of Gas Suppression system Control Panel complete with Smoke Detector, Heat detector, Manual Call point, Manual release abort each 01 No complete with connecting with standard size of cable all as specified and directed
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail